Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.079
Filtrar
1.
Echocardiography ; 41(5): e15828, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38762785

RESUMO

OBJECTIVES: To evaluate the clinical utility of two dimensional (2D) ultrasound combined with spatiotemporal image correlation (STIC) in diagnosing interrupted aortic arch (IAA) in fetal life. METHODS: A total of 53 cases of fetal IAA were diagnosed using 2D ultrasound combined with STIC, and 53 normal fetuses of the same gestational week were selected. These cases were retrospectively analyzed to assess the utility of employing 2D ultrasound combined with STIC in the diagnosis of IAA. RESULTS: 2D ultrasound combined with STIC detected 22 cases of type A IAA, 24 cases of type B IAA, and seven cases of type C IAA. Furthermore, combining 2D ultrasound with STIC enabled dynamic visualization of the IAA, aiding in prenatal diagnosis. The diagnostic coincidence rate of IAA was found to be higher in the HD-flow combined with STIC than that in the 2D combined with HD-flow. CONCLUSION: HD-flow combined with STIC can assist in diagnosing fetal IAA, and this technique has important clinical value.


Assuntos
Aorta Torácica , Ultrassonografia Pré-Natal , Humanos , Feminino , Ultrassonografia Pré-Natal/métodos , Gravidez , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/anormalidades , Aorta Torácica/embriologia , Estudos Retrospectivos , Adulto , Reprodutibilidade dos Testes , Coração Fetal/diagnóstico por imagem
3.
BMC Med Inform Decis Mak ; 24(1): 128, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773456

RESUMO

BACKGROUND: Accurate segmentation of critical anatomical structures in fetal four-chamber view images is essential for the early detection of congenital heart defects. Current prenatal screening methods rely on manual measurements, which are time-consuming and prone to inter-observer variability. This study develops an AI-based model using the state-of-the-art nnU-NetV2 architecture for automatic segmentation and measurement of key anatomical structures in fetal four-chamber view images. METHODS: A dataset, consisting of 1,083 high-quality fetal four-chamber view images, was annotated with 15 critical anatomical labels and divided into training/validation (867 images) and test (216 images) sets. An AI-based model using the nnU-NetV2 architecture was trained on the annotated images and evaluated using the mean Dice coefficient (mDice) and mean intersection over union (mIoU) metrics. The model's performance in automatically computing the cardiac axis (CAx) and cardiothoracic ratio (CTR) was compared with measurements from sonographers with varying levels of experience. RESULTS: The AI-based model achieved a mDice coefficient of 87.11% and an mIoU of 77.68% for the segmentation of critical anatomical structures. The model's automated CAx and CTR measurements showed strong agreement with those of experienced sonographers, with respective intraclass correlation coefficients (ICCs) of 0.83 and 0.81. Bland-Altman analysis further confirmed the high agreement between the model and experienced sonographers. CONCLUSION: We developed an AI-based model using the nnU-NetV2 architecture for accurate segmentation and automated measurement of critical anatomical structures in fetal four-chamber view images. Our model demonstrated high segmentation accuracy and strong agreement with experienced sonographers in computing clinically relevant parameters. This approach has the potential to improve the efficiency and reliability of prenatal cardiac screening, ultimately contributing to the early detection of congenital heart defects.


Assuntos
Cardiopatias Congênitas , Ultrassonografia Pré-Natal , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Feminino , Gravidez , Coração Fetal/diagnóstico por imagem , Coração Fetal/anatomia & histologia
4.
Biomed Phys Eng Express ; 10(4)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38781934

RESUMO

Congenital heart defects (CHD) are one of the serious problems that arise during pregnancy. Early CHD detection reduces death rates and morbidity but is hampered by the relatively low detection rates (i.e., 60%) of current screening technology. The detection rate could be increased by supplementing ultrasound imaging with fetal ultrasound image evaluation (FUSI) using deep learning techniques. As a result, the non-invasive foetal ultrasound image has clear potential in the diagnosis of CHD and should be considered in addition to foetal echocardiography. This review paper highlights cutting-edge technologies for detecting CHD using ultrasound images, which involve pre-processing, localization, segmentation, and classification. Existing technique of preprocessing includes spatial domain filter, non-linear mean filter, transform domain filter, and denoising methods based on Convolutional Neural Network (CNN); segmentation includes thresholding-based techniques, region growing-based techniques, edge detection techniques, Artificial Neural Network (ANN) based segmentation methods, non-deep learning approaches and deep learning approaches. The paper also suggests future research directions for improving current methodologies.


Assuntos
Aprendizado Profundo , Cardiopatias Congênitas , Redes Neurais de Computação , Ultrassonografia Pré-Natal , Humanos , Cardiopatias Congênitas/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Gravidez , Feminino , Processamento de Imagem Assistida por Computador/métodos , Ecocardiografia/métodos , Algoritmos , Coração Fetal/diagnóstico por imagem , Feto/diagnóstico por imagem
5.
Int J Cardiovasc Imaging ; 40(5): 1157-1158, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38652393

RESUMO

Transposition of the great arteries (TGA) is a cyanotic congenital heart disease characterized by ventriculoarterial discordance and atrioventricular concordance with the great arteries in a parallel relationship. Prenatal diagnosis of TGA has implications for postnatal outcomes, allowing for planned delivery and perinatal management. Three-dimensional virtual or physical models of fetal TGA allow better understanding of fetal cardiac anomalies by parents and interactive discussion among the multidisciplinary team (obstetricians, pediatricians, maternal-fetal specialists, pediatric cardiologists, and cardiovascular surgeons), as well as continuing medical education.


Assuntos
Coração Fetal , Valor Preditivo dos Testes , Transposição dos Grandes Vasos , Ultrassonografia Pré-Natal , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Transposição dos Grandes Vasos/fisiopatologia , Humanos , Gravidez , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiopatologia , Feminino , Imageamento Tridimensional , Modelos Cardiovasculares , Idade Gestacional , Modelagem Computacional Específica para o Paciente , Prognóstico , Interpretação de Imagem Assistida por Computador
6.
J Perinat Med ; 52(5): 538-545, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38639637

RESUMO

OBJECTIVES: Cardiopulmonary and infectious complications are more common in preterm newborns after preterm premature rupture of membranes (pPROM). Fetal echocardiography may be helpful in predicting neonatal condition. Our aim was to assess the cardiovascular changes in fetuses from pregnancies complicated by pPROM and possible utility in predicting the intrauterine or neonatal infection, and neonatal heart failure (HF). METHODS: It was a prospective study enrolling 46 women with singleton pregnancies complicated by pPROM between 18+0 and 33+6 weeks of gestation and followed until delivery. 46 women with uncomplicated pregnancies served as a control group. Fetal echocardiographic examinations with the assessment of cardiac structure and function (including pulmonary circulation) were performed in all patients. RESULTS: Mean gestational age of pPROM patients was 26 weeks. Parameters suggesting impaired cardiac function in fetuses from pPROM were: higher right ventricle Tei index (0.48 vs. 0.42 p<0.001), lower blood flow velocity in Ao z-score (0.14 vs. 0.84 p=0.005), lower cardiovascular profile score (CVPS), higher rate of tricuspid regurgitation (18.2 % vs. 4.4 % p=0.04) and pericardial effusion (32.6 vs. 0 %). Intrauterine infection was diagnosed in 18 patients (39 %). 4 (8.7 %) newborns met the criteria of early onset sepsis (EOS). HF was diagnosed in 9 newborns. In fetal echocardiographic examination HF group had shorter mitral valve inflow time and higher left ventricle Tei index (0.58 vs. 0.49 p=0.007). CONCLUSIONS: Worse cardiac function was observed in fetuses from pPROM compared to fetuses from uncomplicated pregnancies.


Assuntos
Ecocardiografia , Ruptura Prematura de Membranas Fetais , Ultrassonografia Pré-Natal , Humanos , Feminino , Gravidez , Ruptura Prematura de Membranas Fetais/diagnóstico , Ruptura Prematura de Membranas Fetais/diagnóstico por imagem , Adulto , Ecocardiografia/métodos , Estudos Prospectivos , Ultrassonografia Pré-Natal/métodos , Recém-Nascido , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiopatologia , Estudos de Casos e Controles , Idade Gestacional
7.
BMC Pregnancy Childbirth ; 24(1): 264, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605306

RESUMO

BACKGROUND: Maternal diabetes adversely affects fetal cardiovascular system development. Previous studies have reported that the fetuses of mothers with diabetes exhibit both structural and functional changes; nevertheless, prior studies have not examined the association between glucose control and fetal cardiac morphology and performance. Thus, the objective was to determine the association between fetal cardiac morphology and function and maternal glucose control in type 1 diabetes and to compare the differences in measured cardiac parameters between the fetuses of mothers with diabetes and healthy controls. METHODS: In this prospective, longitudinal case-control study - including 62 pregnant women with type 1 diabetes mellitus and 30 healthy pregnant women - fetal cardiac assessment using B-mode, M-mode, and spectral pulsed-wave Doppler was performed in the second and third trimesters. In women with T1DM, glycated hemoglobin and data obtained from glucose sensors - including the percentage of time in, below, and above the range (TIR, TBR, and TAR, respectively), and coefficient of variation (CV) - were analyzed across three time periods: the last menstrual period to 13 (V1), 14-22 (V2), and 23-32 weeks (V3) of gestation. Fetal cardiac indices were compared between groups, and the correlation between glucose control and fetal cardiac indices was assessed. RESULTS: At 28-32 weeks, the fetuses of women with T1DM exhibited increased left ventricular end-diastolic length, relative interventricular septum thickness, right ventricular cardiac output, and pulmonary valve peak systolic velocity compared with healthy controls. At 18-22 weeks, pulmonary and aortic valve diameters, left and right ventricular stroke volumes, and left cardiac output inversely correlated with the CV and glycated hemoglobin levels at V1 and V2. Furthermore, at 28-32 weeks, pulmonary and aortic valve diameters, left ventricular stroke volume, cardiac output, and right/left atrioventricular valve ratio inversely correlated with the TBR at V1, V2, and V3. Moreover, diastolic functional parameters correlated with the TAR and glycated hemoglobin levels, particularly after the first trimester. CONCLUSION: In women with T1DM, maternal hyperglycemia during pregnancy correlates with fetal diastolic function, whereas glucose variability and hypoglycemia inversely correlate with fetal left ventricular systolic function in the second and third trimesters.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Gestacional , Síndrome de Quebra de Nijmegen , Gravidez , Humanos , Feminino , Diabetes Mellitus Tipo 1/complicações , Ecocardiografia Doppler , Glicemia , Hemoglobinas Glicadas , Estudos Prospectivos , Estudos de Casos e Controles , Estudos Longitudinais , Coração Fetal/diagnóstico por imagem , Hemodinâmica , Ultrassonografia Pré-Natal
8.
Radiol Cardiothorac Imaging ; 6(2): e230182, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38602469

RESUMO

Fetal cardiac MRI using Doppler US gating is an emerging technique to support prenatal diagnosis of congenital heart disease and other cardiovascular abnormalities. Analogous to postnatal electrocardiographically gated cardiac MRI, this technique enables directly gated MRI of the fetal heart throughout the cardiac cycle, allowing for immediate data reconstruction and review of image quality. This review outlines the technical principles and challenges of cardiac MRI with Doppler US gating, such as loss of gating signal due to fetal movement. A practical workflow of patient preparation for the use of Doppler US-gated fetal cardiac MRI in clinical routine is provided. Currently applied MRI sequences (ie, cine or four-dimensional flow imaging), with special consideration of technical adaptations to the fetal heart, are summarized. The authors provide a literature review on the clinical benefits of Doppler US-gated fetal cardiac MRI for gaining additional diagnostic information on cardiovascular malformations and fetal hemodynamics. Finally, future perspectives of Doppler US-gated fetal cardiac MRI and further technical developments to reduce acquisition times and eliminate sources of artifacts are discussed. Keywords: MR Fetal, Ultrasound Doppler, Cardiac, Heart, Congenital, Obstetrics, Fetus Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Imageamento por Ressonância Magnética , Cuidado Pré-Natal , Feminino , Gravidez , Humanos , Radiografia , Coração Fetal/diagnóstico por imagem , Tecnologia
9.
Biomed Eng Online ; 23(1): 39, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566181

RESUMO

BACKGROUND: Congenital heart disease (CHD) is one of the most common birth defects in the world. It is the leading cause of infant mortality, necessitating an early diagnosis for timely intervention. Prenatal screening using ultrasound is the primary method for CHD detection. However, its effectiveness is heavily reliant on the expertise of physicians, leading to subjective interpretations and potential underdiagnosis. Therefore, a method for automatic analysis of fetal cardiac ultrasound images is highly desired to assist an objective and effective CHD diagnosis. METHOD: In this study, we propose a deep learning-based framework for the identification and segmentation of the three vessels-the pulmonary artery, aorta, and superior vena cava-in the ultrasound three vessel view (3VV) of the fetal heart. In the first stage of the framework, the object detection model Yolov5 is employed to identify the three vessels and localize the Region of Interest (ROI) within the original full-sized ultrasound images. Subsequently, a modified Deeplabv3 equipped with our novel AMFF (Attentional Multi-scale Feature Fusion) module is applied in the second stage to segment the three vessels within the cropped ROI images. RESULTS: We evaluated our method with a dataset consisting of 511 fetal heart 3VV images. Compared to existing models, our framework exhibits superior performance in the segmentation of all the three vessels, demonstrating the Dice coefficients of 85.55%, 89.12%, and 77.54% for PA, Ao and SVC respectively. CONCLUSIONS: Our experimental results show that our proposed framework can automatically and accurately detect and segment the three vessels in fetal heart 3VV images. This method has the potential to assist sonographers in enhancing the precision of vessel assessment during fetal heart examinations.


Assuntos
Aprendizado Profundo , Gravidez , Feminino , Humanos , Veia Cava Superior , Ultrassonografia , Ultrassonografia Pré-Natal/métodos , Coração Fetal/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
10.
Early Hum Dev ; 192: 106006, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598864

RESUMO

BACKGROUND: Behcet's disease usually progresses with remission during pregnancy, but early subtle changes might be detected in the heart of these fetuses due to inflammation. AIMS: We aimed to evaluate the cardiac functions in fetuses of pregnant women with Behcet's disease (BD). STUDY DESIGN: Prospective case-control study. SUBJECTS: This prospective study enrolled pregnant women diagnosed with Behcet's disease before pregnancy. Twenty-four pregnancies with Behcet's disease and 48 healthy pregnancies were included at 32-34 gestational weeks. OUTCOME MEASURES: Pulsed-wave Doppler and tissue Doppler imaging (TDI) were used to assess cardiac functions. RESULTS: Right ventricle (RV) E (early) wave and left ventricle (LV) E were significantly increased in pregnancies with BD (p = .008, p = .041, respectively). Decreased right ventricle E' (peak systolic velocity) was detected with TDI in the case group (6.2 ± 0.5, p < .001). E/E' ratios for RV and LV were significantly increased in the case group (p < .001, p = .001, respectively). The correlation between the duration of the disease and fetal cardiac functions was also evaluated. For RV, E (r = 0.735, p < .001), E' (r = -0.735, p < .001), E/E' (r = 0.894, p < .001), were strongly correlated with the disease duration. The study also showed the correlation between disease duration and LV E' (r = -0.735, p = .005), LV E (r = 0.750, p < .001), and LV E/E' (r = 0.820, p < .001). CONCLUSION: This is the first study to evaluate the fetal cardiac functions in fetuses of pregnancies with BD. Although BD usually progresses with remission during pregnancy, early subclinical diastolic changes might occur in the heart of these fetuses due to inflammation.


Assuntos
Síndrome de Behçet , Coração Fetal , Ultrassonografia Pré-Natal , Humanos , Feminino , Gravidez , Síndrome de Behçet/fisiopatologia , Síndrome de Behçet/diagnóstico por imagem , Estudos de Casos e Controles , Adulto , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiopatologia , Estudos Prospectivos
11.
J Am Heart Assoc ; 13(6): e031184, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38497437

RESUMO

BACKGROUND: Distances between delivery and cardiac services can make the care of fetuses with cardiac disease at risk of acute cardiorespiratory instability at birth a challenge. In 2013 we implemented a fetal echocardiography-based algorithm targeting fetuses considered high risk for acute cardiorespiratory instability at ≤2 hours of birth for delivery in our pediatric cardiac operating room of our children's hospital, and, herein, examine our experience. METHODS AND RESULTS: We reviewed maternal and postnatal medical records of all fetuses with cardiac disease encountered January 2013 to March 2022 considered high risk for acute cardiorespiratory instability. Secondary analysis was performed including all fetuses with diagnoses of d-transposition of the great arteries/intact ventricular septum (d-TGA/IVS) and hypoplastic left heart syndrome (HLHS) encountered over the study period. Forty fetuses were considered high risk for acute cardiorespiratory instability: 15 with d-TGA/IVS and 7 with HLHS with restrictive atrial septum, 4 with absent pulmonary valve syndrome, 3 with obstructed anomalous pulmonary veins, 2 with severe Ebstein anomaly, 2 with thoracic/intracardiac tumors, and 7 others. Pediatric cardiac operating room delivery occurred for 33 but not for 7 (5 with d-TGA/IVS, 2 with HLHS with restrictive atrial septum). For high-risk cases, fetal echocardiography had a positive predictive value of 50% for intervention/extracorporeal membrane oxygenation/death at ≤2 hours and 70% at ≤24 hours. Of "low-risk" cases, 6/46 with d-TGA/IVS and 0/45 with HLHS required intervention at ≤2 hours. Fetal echocardiography for predicting intervention/extracorporeal membrane oxygenation/death at ≤2 hours had a sensitivity of 67%, specificity 93%, and positive and negative predictive values of 80% and 87%, respectively, for d-TGA/IVS, and 100%, 95%, 71%, and 100% for HLHS, respectively. CONCLUSIONS: Fetal echocardiography can predict the need for urgent intervention in a majority with d-TGA/IVS and HLHS and in half of the entire spectrum of high-risk cardiac disease.


Assuntos
Cardiopatias Congênitas , Síndrome do Coração Esquerdo Hipoplásico , Transposição dos Grandes Vasos , Gravidez , Recém-Nascido , Feminino , Humanos , Criança , Salas Cirúrgicas , Coração Fetal/diagnóstico por imagem , Coração Fetal/cirurgia , Ultrassonografia Pré-Natal/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Estudos Retrospectivos
12.
J Perinat Med ; 52(3): 322-326, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38298153

RESUMO

OBJECTIVES: To evaluate the changes of cardiac morphology and function in fetuses conceived through assisted reproductive technologies (ART) by speckle tracking echocardiography. METHODS: A retrospective study was conducted in 101 spontaneously conceived (SC) fetuses and 99 ART-conceived ones. Fetal echocardiography was performed, fetal cardiac morphology and function were analyzed using two-dimensional speckle tracking software, including global sphericity index (GSI), global longitudinal strain (GLS), fractional area change (FAC) of the left and right ventricles, as well as segmental sphericity index (SI), end-diastolic diameter (ED), and fractional shortening (FS) in 24 segments. RESULTS: Compared to the SC fetuses, the ART-conceived fetuses exhibited decreased GSI (median [interquartile range], 1.22 [1.16-1.27] vs. 1.18 [1.11-1.24], p=0.007), decreased right ventricular GLS (24.9 [21.5-27.6] vs. 23.2 [20.4-26.8], p=0.026), and decreased right ventricular FAC (mean ± standard deviation, 39.7 ± 6.4 vs. 37.2 ± 7.1, p=0.003). Analysis of the 24 segments showed that ART-conceived fetuses had reduced SI in the apical segments of right ventricle and increased ED in several segments of the right ventricle. CONCLUSIONS: Fetuses conceived through ART had a more spherical shape of the global heart and predominantly right-sided cardiac remodeling and systolic function impairment.


Assuntos
Ecocardiografia , Coração Fetal , Humanos , Estudos Retrospectivos , Coração Fetal/diagnóstico por imagem , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Técnicas de Reprodução Assistida
14.
IEEE J Biomed Health Inform ; 28(5): 2943-2954, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38412077

RESUMO

In the fetal cardiac ultrasound examination, standard cardiac cycle (SCC) recognition is the essential foundation for diagnosing congenital heart disease. Previous studies have mostly focused on the detection of adult CCs, which may not be applicable to the fetus. In clinical practice, localization of SCCs needs to recognize end-systole (ES) and end-diastole (ED) frames accurately, ensuring that every frame in the cycle is a standard view. Most existing methods are not based on the detection of key anatomical structures, which may not recognize irrelevant views and background frames, results containing non-standard frames, or even it does not work in clinical practice. We propose an end-to-end hybrid neural network based on an object detector to detect SCCs from fetal ultrasound videos efficiently, which consists of 3 modules, namely Anatomical Structure Detection (ASD), Cardiac Cycle Localization (CCL), and Standard Plane Recognition (SPR). Specifically, ASD uses an object detector to identify 9 key anatomical structures, 3 cardiac motion phases, and the corresponding confidence scores from fetal ultrasound videos. On this basis, we propose a joint probability method in the CCL to learn the cardiac motion cycle based on the 3 cardiac motion phases. In SPR, to reduce the impact of structure detection errors on the accuracy of the standard plane recognition, we use XGBoost algorithm to learn the relation knowledge of the detected anatomical structures. We evaluate our method on the test fetal ultrasound video datasets and clinical examination cases and achieve remarkable results. This study may pave the way for clinical practices.


Assuntos
Coração Fetal , Interpretação de Imagem Assistida por Computador , Redes Neurais de Computação , Ultrassonografia Pré-Natal , Humanos , Ultrassonografia Pré-Natal/métodos , Feminino , Gravidez , Interpretação de Imagem Assistida por Computador/métodos , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiologia , Algoritmos , Cardiopatias Congênitas/diagnóstico por imagem , Gravação em Vídeo/métodos
15.
BMC Pregnancy Childbirth ; 24(1): 141, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38365664

RESUMO

OBJECTIVE: Whether or not the effects of anemia in the early phase, while the fetuses attempts to increase cardiac output to meet oxygen requirement in peripheral organs, is detrimental to the fetal developing vital organs is little-known. The objective of this is to compare prenatal cardiovascular changes and post-abortal cellular damages in the myocardium as a pumping organ and the brain as a perfused organ between anemic fetuses (using fetal Hb Bart's disease as a study model) in pre-hydropic phase and non-anemic fetuses. METHODS: Fetuses affected by Hb Bart's disease and non-anemic fetuses at 16-22 weeks were recruited to undergo comprehensive fetal echocardiography. Cord blood analysis was used to confirm the definite diagnosis of fetal Hb Bart's disease and normal fetuses. Fetal cardiac and brain tissues were collected shortly after pregnancy termination for the determination of oxidative stress and mitochondrial function, including mitochondrial ROS production and mitochondrial membrane changes. RESULTS: A total of 18 fetuses affected by Hb Bart's disease and 13 non-anemic fetuses were recruited. The clinical characteristics of both groups were comparable. The affected fetuses showed a significant increase in cardiac dimensions, cardiac function, cardiac output and brain circulation without deteriorating cardiac contractility and preload. However, in the affected fetuses, mitochondrial dysfunction was clearly demonstrated in brain tissues and in the myocardium, as indicated by a significant increase in the membrane potential change (p-value < 0.001), and a significant increase in ROS production in brain tissues, with a trend to increase in myocardium. The findings indicated cellular damage in spite of good clinical compensation. CONCLUSION: The new insight is that, in response to fetal anemia, fetal heart increases in size (dilatation) and function to increase cardiac output and blood flow velocity to provide adequate tissue perfusion, especially brain circulation. However, the myocardium and brain showed a significant increase in mitochondrial dysfunction, suggesting cellular damage secondary to anemic hypoxia. The compensatory increase in circulation could not completely prevent subtle brain and heart damage.


Assuntos
Anemia , Doenças Fetais , Hemoglobinas Anormais , Doenças Mitocondriais , Talassemia alfa , Feminino , Gravidez , Humanos , Segundo Trimestre da Gravidez , Espécies Reativas de Oxigênio , Hemoglobinas Anormais/análise , Doenças Fetais/diagnóstico , Coração Fetal/diagnóstico por imagem , Miocárdio/química , Edema , Débito Cardíaco
16.
Pediatr Cardiol ; 45(4): 740-748, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38393337

RESUMO

Morphology and function in a fetal heart with severe tricuspid regurgitation remains challenging. The aim of this study was to assess cardiac morphology and function in fetuses with severe tricuspid regurgitation by fetal heart quantification (HQ) and to assess the practical value of fetal HQ. Clinical information was analyzed for 63 pregnant women who underwent fetal cardiac ultrasonography. The women were divided into those who had a fetus with severe tricuspid regurgitation (n = 20) and those with a normal fetus (n = 40). The global sphericity index (GSI), fractional area change (FAC), and global longitudinal strain (GLS) of both ventricles and the sphericity index (SI) and fractional shortening (FS) of 24 segments were quantified by fetal HQ using speckle tracking imaging. Fetuses with severe tricuspid regurgitation had a significantly lower GSI (1.14 ± 0.10 vs. 1.26 ± 0.08, p < 0.001) and a higher GSI Z-score (-0.98 ± 1.01 vs. 0.25 ± 0.87, p < 0.001) as well as a significantly lower right ventricular FAC (36.50 ± 7.34% vs. 45.19 ± 3.39%, p < 0.001), FAC Z-score (-1.02 ± 1.41 vs. 0.49 ± 0.74, p < 0.001), and GLS (-21.01 ± 5.66% vs. 45.19 ± 3.49%, p < 0.001). The SI and SI Z-score were significantly lower in segments 1-18 of the right ventricle in fetuses with severe tricuspid regurgitation (p < 0.05); furthermore, FS of segments 1-12 and 19-24 and the FS Z-score of segments 18-24 were significantly lower in fetuses with severe tricuspid regurgitation (p < 0.05). Fetal HQ is useful for evaluation of cardiac morphology and function in fetuses with severe tricuspid regurgitation and can provide important reference information for both clinical diagnosis and treatment.


Assuntos
Insuficiência da Valva Tricúspide , Humanos , Feminino , Gravidez , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem , Ventrículos do Coração , Ultrassonografia Pré-Natal/métodos
17.
Echocardiography ; 41(1): e15743, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284679

RESUMO

BACKGROUND: Isolated redundant foramen ovale flap aneurysm (RFOA) in the absence of restrictive foramen ovale is believed to be a cause for pseudocoarctation of aorta since the impediment of blood flow to the left heart can be severe, resembling the picture of left ventricular hypoplasia with retrograde aortic flow. The primary objective of the study is to find whether RFOA is always a benign lesion. The main focus of the study is to share my experience in particular on fetuses having redundant foramen ovale flap aneurysm developing into coarctation of aorta and to study the associated factors. METHODS: Retrospective study (January 2020 to June 2023). All fetuses with RFOA associated with and without congenital heart defects were included. Fetuses with restrictive foramen ovale and RFOA with single ventricle hearts were excluded. The imaging, in-utero hemodynamics, pregnancy, and postnatal outcomes with at least 3 months follow-up were presented. RESULTS: During the study period, a total of 1499 fetal echocardiography were performed. Twenty-two fetuses with RFOA were included. Fourteen fetuses had isolated RFOA and eight had associated abnormalities [extracardiac (n = 5); intracardiac (n = 2), Both (n = 1)]. Genetic evaluation were performed only in fetuses with associated defects were normal. Postnatally all isolated RFOA fetuses had no aortic arch obstruction. Fetuses with associated aberrant right subclavian artery, isolated left superior vena cava, absent ductus venosus and ventricular septal defects developed aortic arch obstruction after birth. RFOA causes smallish left ventricle in fetuses with tetralogy of Fallot which recovered to normal size postnatally. CONCLUSION: Isolated RFOA can be benign, however, if it is associated with cardiac or extracardiac anomalies predominantly resulted in aortic arch obstruction. Though it is a cause for pseudocoarctation of aorta, through postnatal reassessment of aortic arch is mandatory. Careful search for intracardiac and systemic venous anomalies is recommended. It created confusion regarding adequacy of left ventricle when associated with congenital heart defects.


Assuntos
Aneurisma , Forame Oval , Cardiopatias Congênitas , Gravidez , Feminino , Humanos , Estudos Retrospectivos , Veia Cava Superior , Ultrassonografia Pré-Natal , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Diagnóstico Pré-Natal , Coração Fetal/diagnóstico por imagem , Hemodinâmica
18.
BMC Pregnancy Childbirth ; 24(1): 57, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38212679

RESUMO

BACKGROUND: Hyperglycemia during pregnancy can affect fetal heart in many ways, including causing cardiac malformation, leading to hypertrophic cardiomyopathy and cardiac dysfunction. Echocardiographic evaluation can assist identify alterations in heart structure, morphology and function, enabling prompt monitoring and management. However, according to earlier research, the cardiac alterations are modest in hyperglycemic mothers' fetuses, and might not be detectable using conventional methods and it is also unclear whether these changes are related to the metabolism of mothers. Fetal Heart Quantification (Fetal HQ) can assess ventricular geometry and function more sensitively and thoroughly, and identify sub-clinical cardiac dysfunction. The purpose of this study was to evaluate fetal heart by Fetal HQ in fetuses of hyperglycemic mothers who either had pre-gestational or gestational diabetes and to correlate them with maternal metabolic indices. METHODS: The fetuses of 25 gestational age-matched control mothers, 48 women with gestational diabetes mellitus (GDM), and 11 women with diabetes mellitus (DM) were included in the prospective case-control research. Using fetal echocardiography and speckle tracking echocardiography (STE), the heart of the fetus was evaluated. Differences in the groups' anthropometric, metabolic, and cardiac parameters were examined. It was assessed whether maternal features, prenatal glucose, lipids, and maternal hemoglobin A1c (HbA1c) correlated with fetal cardiac parameters. RESULTS: The LV EDV and ESV were significantly higher in the GDM group as compared to the DM group (p < 0.05). The GSI% was significantly lower in the GDM group compared with the control (p < 0.05). The LV SV and CO of the GDM group were both significantly higher compared with the DM group (p < 0.05). There was a significant decrease in RV FS for segments 1-7 in GDM fetuses compared to the control (p < 0.05) and for segments 5-10 compared to DM (p < 0.05). Fetal cardiac morphology and function indices correlate with maternal pregestational weight, BMI, early pregnancy fast glucose, lipids, and glycemic control levels. CONCLUSIONS: Fetuses exposed to gestational diabetes have altered heart morphology and function that is linked to maternal metabolic parameters, which presents a special indication for performing geometry and function cardiac assessment. Fetal HQ can be employed to evaluate the fetal cardiac shape and function in fetuses exposed to gestational diabetes.


Assuntos
Diabetes Gestacional , Cardiopatias , Gravidez , Feminino , Humanos , Coração Fetal/diagnóstico por imagem , Glucose , Lipídeos , Ultrassonografia Pré-Natal/métodos
19.
Heart Rhythm ; 21(5): 600-609, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38266752

RESUMO

BACKGROUND: The motion relationship and time intervals of the pulsed-wave Doppler (PWD) spectrum are essential for diagnosing fetal arrhythmia. However, few technologies currently are available to automatically calculate fetal cardiac time intervals (CTIs). OBJECTIVE: The purpose of this study was to develop a fetal heart rhythm intelligent quantification system (HR-IQS) for the automatic extraction of CTIs and establish the normal reference range for fetal CTIs. METHODS: A total of 6498 PWD spectrums of 2630 fetuses over the junction between the left ventricular inflow and outflow tracts were recorded across 14 centers. E, A, and V waves were manually labeled by 3 experienced fetal cardiologists, with 17 CTIs extracted. Five-fold cross-validation was performed for training and testing of the deep learning model. Agreement between the manual and HR-IQS-based values was evaluated using the intraclass correlation coefficient and Spearman's rank correlation coefficient. The Jarque-Bera test was applied to evaluate the normality of CTIs' distributions, and the normal reference range of 17 CTIs was established with quantile regression. Arrhythmia subset was compared with the non-arrhythmia subset using the Mann-Whitney U test. RESULTS: Significant positive correlation (P <.001) and moderate-to-excellent consistency (P <.001) between the manual and HR-IQS automated measurements of CTIs was found. The distribution of CTIs was non-normal (P <.001). The normal range (2.5th to 97.5th percentiles) was successfully established for the 17 CTIs. CONCLUSIONS: Using our HR-IQS is feasible for the automated calculation of CTIs in practice and thus could provide a promising tool for the assessment of fetal rhythm and function.


Assuntos
Arritmias Cardíacas , Coração Fetal , Frequência Cardíaca Fetal , Humanos , Feminino , Estudos Prospectivos , Gravidez , Frequência Cardíaca Fetal/fisiologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiologia , Idade Gestacional , Ultrassonografia Pré-Natal/métodos
20.
Echocardiography ; 41(1): e15736, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284669

RESUMO

OBJECTIVE: To evaluate both short and mid-term effects of maternal COVID-19 on cardiac functions of fetuses and children. METHODS: The present case-control study was conducted on 36 pregnant women who had COVID-19 infection in the second trimester of pregnancy and 30 pregnant women as healthy controls. Fetal, neonatal, and infant cardiac functions were compared between the groups. Assessment of fetal cardiac functions were performed in the last trimester of the pregnancy at least 6 weeks after the recovery of infection. The first postnatal echo was performed within the first 2 weeks and the follow-up (second) echo was performed in the 6-8 weeks of life. RESULTS: The demographic data were similar between groups. Interventricular septum and left ventricular posterior wall end-diastolic dimensions were significantly higher in the study group in both fetal, neonatal, and infant periods. Impaired diastolic functions of right and left ventricles were detected and myocardial performance indexes with tissue doppler imaging of both lateral walls and septum were significantly higher than controls at all periods. CONCLUSION: Maternal COVID-19 seems to have a global impact on the cardiac functions of babies in the short and mid-term periods after maternal recovery.


Assuntos
COVID-19 , Ecocardiografia Doppler , Recém-Nascido , Lactente , Criança , Gravidez , Feminino , Humanos , Ecocardiografia Doppler/métodos , Coração Fetal/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Terceiro Trimestre da Gravidez , Ultrassonografia Pré-Natal/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...