Health Phys ; 97(2 Suppl): S140-4, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19590267

RESUMO

Ongoing uncertainties have existed regarding possible effects at low photon energies of two copper filters covering Element 1 of the Harshaw Type-8814 thermoluminescent dosimeter badge casing. To address these, Brookhaven National Laboratory's (BNL) Personnel Monitoring Group conducted a test in which Type-8814 badges with one copper filter covering Element 1 were irradiated at several low-energy levels side-by-side with the same number of badges with two copper filters covering Element 1. A review of exposures to personnel at Brookhaven Laboratory to possible low-energy photon flux was also conducted. From both the test and the review of exposures, it can be concluded that, for radiological work under the conditions at BNL, there is no apparent dosimetric difference if one or two copper filters cover Element 1 of the Type-8814 badge.


Assuntos
Cobre , Filtração , Exposição Ocupacional , Doses de Radiação , Dosimetria Termoluminescente/efeitos adversos , Humanos
2.
Radiol. bras ; 41(1): 35-38, jan.-fev. 2008. tab
Artigo em Inglês, Português | LILACS | ID: lil-477721

RESUMO

OBJETIVO: Este trabalho avaliou doses recebidas por acompanhantes que compartilharam o mesmo quarto terapêutico com pacientes tratados com câncer de tireóide ingerindo iodo-131 (131I) e comparou os resultados obtidos aos limites determinados pelas normas brasileiras de radioproteção. MATERIAIS E MÉTODOS: Avaliaram-se seis grupos de pessoas. Cada grupo foi formado por um acompanhante e um paciente, que compartilharam o mesmo quarto terapêutico. Realizaram-se, também, 23 outros experimentos, sendo que nestes um simulador foi usado em substituição à segunda pessoa no quarto terapêutico. As atividades de 131I administradas aos pacientes foram de 3.700 MBq ou 5.550 MBq. Dosímetros termoluminescentes na forma de pó, fluoreto de lítio dopado com magnésio, titânio e sódio foram usados para a avaliação das doses. RESULTADOS: Os resultados mostraram que uma pessoa que compartilha o mesmo quarto terapêutico, durante dois dias, com um paciente tratado com 3.700 MBq ou 5.550 MBq de 131I, seguindo as orientações de radioproteção fornecidas pela equipe médica, é exposta a uma dose média de (0,51 ± 0,02) mSv, para um nível de confiança de 99 por cento. CONCLUSÃO: De acordo com as normas brasileiras, do ponto de vista da radioproteção, não há impedimento acompanhar um paciente de medicina nuclear durante esse tratamento.


OBJECTIVE: The present study evaluated the doses received by companions who had shared therapeutic rooms with patients undergoing treatment with 131-iodine (131I). The results were compared with the limits established by the Brazilian radiation protection regulatory standard. MATERIALS AND METHODS: Six pairs of persons (a patient and a companion sharing a same therapeutic room) were evaluated. Still, other 23 experiments were accomplished with a phantom replacing the companion. The therapeutic 131I activities given to the patients corresponded to 3700 MBq or 5550 MBq. Powdered lithium fluoride thermoluminescent dosimeters doped with magnesium, titanium and sodium were utilized for evaluating the doses. RESULTS: The results demonstrate that a person sharing a same therapeutic room, for two days, with a patient who had been given 3700 MBq or 5550 MBq of 131I, according to radioprotection recommendations, is exposed to a mean dose of (0.51 ± 0.02) mSv for a 99 percent confidence level. CONCLUSION: According to the Brazilian radiation protection standards there is no impediment for a person to accompany a nuclear medicine patient who has been given 3700 MBq or 5550 MBq of 131I during the patient stay in the therapeutic room.


Assuntos
Humanos , Masculino , Feminino , Acompanhantes Formais em Exames Físicos , Medicina Nuclear/estatística & dados numéricos , Proteção Radiológica/métodos , Radiometria , Dosímetros de Radiação , Dosimetria Termoluminescente/efeitos adversos , Equipamentos de Medição de Riscos , Quartos de Pacientes
3.
Radiol. bras ; 37(5): 343-349, set.-out. 2004. ilus, tab
Artigo em Português | LILACS | ID: lil-388276

RESUMO

OBJETIVO: Avaliar a precisão das doses de radiação absorvidas na terapia de transplantes de medula óssea durante a técnica de irradiação de corpo inteiro. MATERIAIS E MÉTODOS: Utilizaram-se 200 pastilhas de sulfato de cálcio com disprósio compactado com teflon (CaSO4 + teflon), calibradas no ar e no "phantom", selecionadas aleatoriamente e dispostas em grupos de cinco no corpo dos pacientes. As leituras dosimétricas foram efetuadas pela leitora Harshaw 4000A. Nove pacientes foram irradiados no corpo inteiro em paralelos e em opostos laterais, utilizando-se unidade de cobalto-60, modelo Alcion II, com taxa de dose de 0,80 Gy/min a 80,5 cm, {campo (10 × 10) cm²}. A dosimetria dessa unidade foi realizada com dosímetro Victoreen 500. Para a determinação da dose média em cada ponto avaliado usaram-se os fatores individuais de calibração das pastilhas no ar e no "phantom", colocando-se um "build up" de 2 mm para superficializar a dose à distância de 300 cm. RESULTADOS: Em 70 por cento dos pacientes obteve-se variação de dose menor que 5 por cento e em 30 por cento dos pacientes essa variação foi inferior a 10 por cento, quando comparados os valores medidos com aqueles calculados em cada ponto. Na cabeça ocorre absorção, em média, de 14 por cento da dose administrada, e nos pulmões, acréscimo de 2 por cento na dose administrada. Nos pacientes com distância látero-lateral maior que 35 cm as variações entre as doses calculadas e medidas podem chegar a 30 por cento da dose desejada, sem o uso de filtros compensadores. CONCLUSÃO: Os valores medidos das doses absorvidas nos diversos pontos anatômicos, comparados aos valores desejados (teóricos), apresentam tolerância de ±10 por cento, considerando-se as diferenças anatômicas existentes, quando utilizados os fatores de calibração individuais das pastilhas.


Assuntos
Humanos , Masculino , Feminino , Transplante de Medula Óssea , Dosimetria Termoluminescente/efeitos adversos , Dosímetros de Radiação/análise , Leucemia/radioterapia , Dosimetria Termoluminescente , Irradiação Corporal Total
4.
Strahlentherapie ; 161(2): 84-5, 1985 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-3975943

RESUMO

A brief survey is given of the application of TLD systems, above all in neutron dosimetry, dosimetry in the irradiation of body parts and beta-radiation as well as in the environment monitoring. Recent communications of literature are mentioned, also concerning the practical application of thermoluminescent dosimetry in the cited fields.


Assuntos
Monitoramento de Radiação , Proteção Radiológica/métodos , Poluentes Radioativos/análise , Dosimetria Termoluminescente/efeitos adversos , Partículas beta/efeitos adversos , Poluentes Ambientais/análise , Nêutrons Rápidos/efeitos adversos , Humanos , Doses de Radiação , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/instrumentação