Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.967
Filtrar
1.
Medicine (Baltimore) ; 103(18): e38058, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38701248

RESUMO

To evaluate the right atrial function in patients with 3-branch coronary artery disease (TBCAD) without myocardial infarction by 2D speckle tracking echocardiography (2D-STE) combined with real-time 3-dimensional echocardiography (RT-3DE). Fifty-six patients admitted to our hospital without myocardial infarction with TBCAD were selected. We divided them into 2 groups according to the coronary angiography results: 28 patients in group B (the rate of stenosis is 50% ~< 75%); 28 patients in group C (the rate of stenosis is ≥75%); in addition, 30 healthy volunteers were screened as group A. All subjects underwent RT-3DE to obtain the right atrial volume (RAVmax, RAVmin, and RAVp), and then we calculated the right atrial passive and active ejection fraction (RAPEF, RAAEF), and maximum volume index (RAVImax). In addition, to measure the strain rates (RASRs, RASRe, RASRa) of the right atrium during systole, early diastole, and late diastole, 2D-STE was applied. Correlations between the 2D-STE parameters and the results of N-terminal pro-brain natriuretic peptide (NT-proBNP) and Gensini scores were analyzed by Pearson linear analysis. Compared with group A, RAPEF and RASRe were reduced, while RAAEF and RASRa were elevated in group B (P < .05). RAPEF, RASRs, RASRe, and RASRa were decreased compared with groups A and B, while RAVmax, RAVmin, RAVp, RAVImax, and RAAEF were increased in group C (P < .05). There was a significant correlation between 2D-STE parameters and the results of NT-proBNP and Gensini scores (P < .05). The storage, conduit, and pump functions of the right atrium are reduced in patients with 3-branch coronary artery disease without myocardial infarction; 2D-STE combined with RT-3DE is valuable in the evaluation of the right atrium in patients with coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Ecocardiografia Tridimensional , Átrios do Coração , Peptídeo Natriurético Encefálico , Humanos , Masculino , Ecocardiografia Tridimensional/métodos , Feminino , Pessoa de Meia-Idade , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Peptídeo Natriurético Encefálico/sangue , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Idoso , Fragmentos de Peptídeos/sangue , Função do Átrio Direito/fisiologia , Ecocardiografia/métodos , Angiografia Coronária/métodos
2.
Sci Rep ; 14(1): 11937, 2024 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789491

RESUMO

Transesophageal echocardiography (TEE) has been the preferred imaging modality to help guide left atrial appendage closure. Newer technologies such as the Nuvision 4D Intracardiac echocardiography (ICE) catheter allow for real-time 3D imaging of cardiac anatomy. There are no direct comparison studies for procedural imaging between TEE and 4D ICE. To evaluate the performance and safety of left atrial appendage (LAA) closure procedures with the Watchman FLX and Amulet, guided by the Nuvision 4D ICE Catheter. This retrospective observational analysis was conducted on institutional LAAO National Cardiovascular Data Registry from January 2022 to March 2023. Patients had undergone LAA closure procedures with the Watchman FLX or Amulet device guided by TEE or a 4D ICE Catheter. The primary outcome evaluated was successful LAAO device placement. A total of 121 patients underwent LAAO device placement with 46 (38.0%) patients guided by 4D ICE during LAAO implantation. The 4D ICE group had a shorter procedural time compared with TEE guidance. Post procedural 45-day TEE post implant was also comparable for both groups with no patients in either group having incomplete closure of the left atrial appendage and peri-device leak > 5 mm. No device related complications (device related access, stroke, or pericardial effusion) occurred in either group at follow-up. There was no significant difference in device implant success or post procedural outcomes at 45 days in either the TEE or 4D ICE group. However, there was a noticeable improvement in procedural time with the 4D ICE catheter.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ecocardiografia Transesofagiana , Humanos , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Masculino , Feminino , Idoso , Estudos Retrospectivos , Ecocardiografia Transesofagiana/métodos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Idoso de 80 Anos ou mais , Ecocardiografia Tridimensional/métodos , Pessoa de Meia-Idade , Ecocardiografia/métodos , Resultado do Tratamento , Cateteres Cardíacos , Oclusão do Apêndice Atrial Esquerdo
3.
Medicine (Baltimore) ; 103(21): e38206, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38788025

RESUMO

OBJECTIVE: To evaluate left atrial volume and function in patients with paroxysmal atrial fibrillation (AF) combined with left atrial appendage thrombosis and patients with paroxysmal AF without left atrial appendage thrombosis by 3-dimensional speckle tracking imaging (3D-STI), and to explore the application value of this set of parameters in the evaluation of left atrial function in patients with paroxysmal AF. MATERIALS AND METHODS: A total of 40 patients with paroxysmal AF admitted from December 2018 to December 2020 were selected as the observation group. All patients with paroxysmal AF in the observation group underwent transesophageal echocardiography. According to the presence of left atrial appendage thrombosis, the patients were divided into the AF without thrombosis group (24 cases) and the AF with thrombosis group (16 cases). Thirty normal people were selected as control group who were chosen as having no heart-related disease. The left atrial volume parameters (Left atrial maximum volume LAVmax, Left atrial minimum volume LAVmin, Left atrial volume before atrial contraction LAVpre-A, Left atrial stroke volume LAEV), left atrial ejection fraction (LAEF) and left atrial strain parameters (Left atrial reservoir longitudinal strain LASr, Left atrial conduit longitudinal strain LAScd, Left atrial contraction longitudinal strain LASct, Left atrial reservoir circumferential strain LASr-c, Left atrial conduit circumferential strain LAScd-c, Left atrial contraction circumferential strain LASct-c) of the 3 groups were measured by 3D-STI. RESULTS: With the progression of paroxysmal AF, the left atrial volume increased, and the reservoir, conduit and contractile function were damaged. The left atrial volume continued to increase, and the reservoir, conduit and contractile function further decreased significantly in patients with AF combined with left atrial appendage thrombosis. LAEF was positively correlated with LASr and LASr_c. CONCLUSION: Real-time 3-dimensional spot tracking imaging (3D-STI) can evaluate the changes in left atrial volume and function in patients with paroxysmal AF, and has a certain reference value for clinical judgment of disease progression and prognosis.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Função do Átrio Esquerdo , Humanos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Função do Átrio Esquerdo/fisiologia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Ecocardiografia Tridimensional/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Ecocardiografia Transesofagiana/métodos , Idoso , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/fisiopatologia
4.
PLoS One ; 19(4): e0302123, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630708

RESUMO

BACKGROUND: Fetal two-dimensional speckle tracking echocardiography (2D-STE) is an emerging technique for assessing fetal cardiac function by measuring global longitudinal strain. Alterations in global longitudinal strain may serve as early indicator of pregnancy complications, making 2D-STE a potentially valuable tool for early detection. Early detection can facilitate timely interventions to reduce fetal and maternal morbidity and mortality. Therefore, the aim of this study was to investigate the feasibility of performing 2D-STE at 16 weeks gestational age. METHODS: This pilot study utilized 50 ultrasound clips of the fetal four-chamber view recorded between 15+5 and 16+2 weeks gestational age from a prospective cohort study. A strict protocol assessed three parameters essential for 2D-STE analysis: fetal four-chamber view ultrasound clip quality, region of interest, and frame rates. Two independent researchers measured global longitudinal strain in all adequate fetal four-chamber view ultrasound clips to determine inter- and intra-operator reliability. RESULTS: Out of the 50 ultrasound clips, 37 (74%) were feasible for 2D-STE analysis. The inter-operator reliability for global longitudinal strain measurements of the left and right ventricles was moderate (ICC of 0.64 and 0.74, respectively), while the intra-operator reliability was good (ICC of 0.76 and 0.79, respectively). CONCLUSIONS: Our findings demonstrate that fetal 2D-STE analysis at 16 weeks gestational age is feasible when adhering to a strict protocol. However, further improvements are necessary to enhance the inter- and intra-operator reliability of 2D-STE at this gestational age.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia , Gravidez , Feminino , Humanos , Idade Gestacional , Projetos Piloto , Reprodutibilidade dos Testes , Estudos de Viabilidade , Estudos Prospectivos , Ecocardiografia/métodos , Ventrículos do Coração , Ecocardiografia Tridimensional/métodos
7.
Echocardiography ; 41(5): e15823, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38678585

RESUMO

The morphologic features of the multiple atrial septal defects assessed by TTE-based 3D imaging were similar to those by 3D-TEE. TTE-based 3D model had excellent visibility, allowing observation of 3D structure of the rims of the defects. It may be useful method for assessment of the multiple atrial septal defects.


Assuntos
Ecocardiografia Tridimensional , Comunicação Interatrial , Veia Cava Inferior , Humanos , Comunicação Interatrial/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Veia Cava Inferior/diagnóstico por imagem , Feminino , Masculino , Adulto
8.
Echocardiography ; 41(3): e15785, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38527004

RESUMO

BACKGROUND: Trans-catheter mitral valve replacement (TMVR) procedures had emerged as an alternative solution for patients who are at high risk for mitral valve surgery. Although cardiac computed tomography (CT) remains the standard method for procedural planning, there is no full agreement on the best systolic phase for quantitation of the neoLVOT. Furthermore, a new three-dimensional trans-esophageal echocardiography (3DTEE) based software was developed to serve as filter and or an alternative for patients who cannot have CT due to any contraindication. AIM: To determine the systolic phase of the cardiac cycle that shows the narrowest NeoLVOT area in order to standardize the way of using these software and then to validate the 3DTEE-based software against the CT-based one as a gold standard, in mitral valve annulus (MA) and NeoLVOT assessment. METHODS: A single center, observational, retrospective study. Initially, a sample of 20 patients (age 62 ± 4 years, 70% men) had CT-based analysis at mid-diastole (80%), early-systole (10%), mid-systole (20%), late-systole (30%-40%), in order to detect the best systolic phase at which the neoLVOT area is the narrowest after TMVR. Then, the end systolic phase was standardized for the analysis of 49 patients (age 57 ± 6 years, 60% men), using both the commercially available CT-based software and the newly available 3DTEE-based software (3mensio Structural Heart, Pie Medical Imaging, The Netherlands). The 3DTEE derived parameters were compared with the gold standard CT-based measurements. RESULTS: The neoLVOT area was significantly narrower at end-systole (224 ± 62 mm2), compared to early-systole (299 ± 70 mm2) and mid-systole (261 ± 75 mm2), (p = .005). Excellent correlation was found between 3DTEE and CT measurements for MA AP diameter (r = .96), IC diameter (r = .92), MA area (r = .96), MA perimeter (r = .94) and NeoLVOT area (r = .96), (all p-values < .0001). Virtual valve sizing was based on annulus measurement and was identical between CT and 3DTEE. Interobserver and intraobserver agreements were excellent for all the measurements with ICCs > .80. CONCLUSIONS: End-systole is the phase that shows the narrowest neoLVOT and hence should be the standard phase used during the analysis. The 3DTEE based analysis using this new software is reliable compared to the CT-based analysis and can be serve as an alternative analysis tool in patients who cannot have CT for any clinical contraindication or as a screening test and/or filter for all patients before proceeding to a detailed CT scan.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Catéteres , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos
9.
Echocardiography ; 41(3): e15798, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38516863

RESUMO

Editing of 3D raw images acquired during transesophageal echocardiography could be similar to the post processing of raw images with digital software used in photography. 3D image editing in echocardiography is often underestimated in clinical practice, and people are satisfied with the first 3D image they are able to obtain during transesophageal examination. In fact, it is often believed to represent solely an aesthetic addition that does not change the information already obtained with 2D and baseline 3D. In reality, it represents a crucial moment to better understand the mechanisms of mitral pathology, avoiding artifacts and misjudgments. The importance of acquiring raw 3D images of the valve having all the necessary information (ring, the leaflet in toto, the right frame rate) allows us then to edit them making them more beautiful and clearer from the point of view of the information received. Nevertheless, by exclusively acquiring a raw 3D with all the necessary information, we can quickly finish the transesophageal examination, reducing its duration and discomfort for the patient, as well as the inherent risk of complications related to the procedure per se.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Fotografação
10.
Early Hum Dev ; 191: 105985, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38513546

RESUMO

BACKGROUND: Increased left atrial volume (LAV) is a marker of cardiovascular risk. Echocardiography standards to assess LAV in adults and children are the biplane area-length method (AL) and method of disks (MOD). LAV in neonatology is usually derived as M-mode ratio between the LA and the Aorta (LAAo). The aim of this study is to determine feasibility and reliability of these methods in neonatal clinical practice. METHODS: Clinically indicated echocardiograms in neonatal intensive care patients were retrospectively analyzed. Feasibility was determined with an image quality score describing insonation angle, foreshortening and wall clarity. Reliability was determined with Bland-Altman and correlation coefficient analysis of intra- and inter-observer measurements. RESULTS: 104 infants ranging from 23 to 39 weeks gestation were included. The feasibility of LAAo, AL and MOD was comparable (median image score 4 out of 6 points). Linear regression between AL and MOD was excellent (R2 0.99). LAAo best-fit with MOD was reached with curve-linear regression (R2 0.28) whereby a LAAo of 1.60 correlated with 1.24 ml/kg, but with a wide 95 % CI. The correlation coefficient within and between observers for LAAo, biplane AL, biplane MOD and monoplane MOD was 0.93 (0.87-0.96), 0.98 (0.96-0.99), 0.98 (0.96-0.99), 0.99 (0.97-0.99) and 0.58 (0.11-0.81), 0.75 (0.44-0.89), 0.92 (0.88-0.98), 0.96 (0.88-0.98) respectively. CONCLUSION: All methods were equally feasible and reliable when repeated by the same observer, but LAAo reliability was poor when repeated by a different observer. Biplane MOD was the most reliable and thus recommended in neonatal practice. Monoplane MOD performed well and could be considered as alternative but might be less accurate.


Assuntos
Ecocardiografia Tridimensional , Adulto , Criança , Recém-Nascido , Humanos , Ecocardiografia Tridimensional/métodos , Reprodutibilidade dos Testes , Terapia Intensiva Neonatal , Estudos Retrospectivos , Átrios do Coração/diagnóstico por imagem
11.
J Heart Lung Transplant ; 43(7): 1183-1187, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38508504

RESUMO

Three-dimensional (3D) echocardiography-derived right ventricular (RV) ejection fraction (EF) and global longitudinal strain (GLS) are valuable RV functional markers; nevertheless, they are substantially load-dependent. Global myocardial work index (GMWI) is a novel parameter calculated by the area of the RV pressure-strain loop. By adjusting myocardial deformation to instantaneous pressure, it may reflect contractility. To test this hypothesis, we enrolled 60 patients who underwent RV pressure-conductance catheterization to determine load-independent markers of RV contractility and ventriculo-arterial coupling. Detailed 3D echocardiography was also performed, and we calculated RV EF, RV GLS, and using the RV pressure trace curve, RV GWMI. While neither RV EF nor GLS correlated with Ees, GMWI strongly correlated with Ees. In contrast, RV EF and GLS showed a relationship with Ees/Ea. By dividing the population based on their Reveal Lite 2 risk classification, different characteristics were seen among the subgroups. RV GMWI may emerge as a useful clinical tool for risk stratification and follow-up in patients with RV dysfunction.


Assuntos
Ecocardiografia Tridimensional , Contração Miocárdica , Volume Sistólico , Função Ventricular Direita , Humanos , Masculino , Feminino , Contração Miocárdica/fisiologia , Pessoa de Meia-Idade , Função Ventricular Direita/fisiologia , Ecocardiografia Tridimensional/métodos , Volume Sistólico/fisiologia , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Pressão Ventricular/fisiologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Cateterismo Cardíaco , Idoso , Adulto
14.
J Am Soc Echocardiogr ; 37(6): 634-640, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38467312

RESUMO

Accurate knowledge of right ventricular (RV) volumes and ejection fraction is fundamental to providing optimal care for pediatric patients with congenital and acquired heart disease, as well as pulmonary hypertension. Traditionally, these volumes have been measured using cardiac magnetic resonance because of its accuracy, reproducibility, and freedom from geometric assumptions. More recently, an increasing number of studies have described the measurement of RV volumes using three-dimensional (3D) echocardiography. In addition, volumes by 3D echocardiography have also been used for outcome research studies in congenital heart surgery. Importantly, 3D echocardiographic acquisitions can be obtained over a small number of cardiac cycles, do not require general anesthesia, and are less costly than CMR. The ease and safety of the 3D echocardiographic acquisitions allow serial studies in the same patient. Moreover, the studies can be performed in various locations, including the intensive care unit, catheterization laboratory, and general clinic. Because of these advantages, 3D echocardiography is ideal for serial evaluation of the same patient. Despite these potential advantages, 3D echocardiography has not become a standard practice in children with congenital and acquired heart conditions. In this report, the authors review the literature on the feasibility, reproducibility, and accuracy of 3D echocardiography in pediatric patients. In addition, the authors investigate the advantages and limitations of 3D echocardiography in RV quantification and offer a pathway for its potential to become a standard practice in the assessment, planning, and follow-up of congenital and acquired heart disease.


Assuntos
Ecocardiografia Tridimensional , Humanos , Ecocardiografia Tridimensional/métodos , Criança , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Reprodutibilidade dos Testes , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Volume Sistólico/fisiologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Pré-Escolar , Lactente , Sensibilidade e Especificidade , Cardiopatias/diagnóstico por imagem , Cardiopatias/fisiopatologia , Cardiopatias/diagnóstico
15.
J Am Soc Echocardiogr ; 37(6): 591-598, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38522488

RESUMO

BACKGROUND: Echocardiographic grading of mitral regurgitation (MR) in mitral valve prolapse (MVP) is challenging. Three-dimensional (3D) vena contracta area (VCA) has been proposed as a valuable method. However, data defining the cutoff values of severity and validation in the subset of patients with MVP are scarce. The aim of this study was to validate the 3D VCA by 3D color-Doppler transesophageal echocardiography (TEE) in patients with MVP and to define the cutoff values of severity grading. The secondary aim was to compare 3D VCA to the effective regurgitant orifice area estimation by proximal isovelocity surface area (EROA-PISA) method. METHODS: A total of 1,138 patients with at least moderate MR who underwent TEE were included. Three-dimensional VCA was measured, and the cutoff value and area under the curve (AUC) for the prediction of severe MR were estimated by receiver operating characteristic curve using a guideline-suggested multiparametric approach as the reference standard. In a subgroup of patients, 3D regurgitant volume (RV) and 3D fraction were calculated from mitral and left ventricular outflow tract stroke volumes to further validate 3D VCA against a 3D volumetric reference standard. RESULTS: The optimal 3D VCA cutoff value for predicting severe MR was 0.45 cm2 (specificity, 0.87; sensitivity, 0.90) with an AUC of 0.95 using a multiparametric approach as reference. Three-dimensional VCA had a good linear correlation with EROA-PISA (r = 0.62, P < .05) with larger values compared to EROA-PISA (0.63 cm2 vs 0.44 cm2, P < .05). A cutoff of 0.50 cm2 (AUC of 0.84; sensitivity, 0.78; specificity, 0.78) predicts an EROA-PISA of 0.40 cm2. Three-dimensional VCA had a good linear correlation with 3D RV (r = 0.56, P < .01), with an AUC of 0.86 to predict a 3D fraction >50%. CONCLUSIONS: The present study suggests 0.45 cm2 as the best cutoff value of 3D VCA to define severe MR in patients with MVP, showing an optimal agreement with the reference standard multiparametric approach and 3D RV.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Ecocardiografia Tridimensional/métodos , Feminino , Masculino , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/fisiopatologia , Pessoa de Meia-Idade , Idoso , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Doppler em Cores/métodos , Reprodutibilidade dos Testes , Valva Mitral/diagnóstico por imagem , Curva ROC , Estudos Retrospectivos
17.
J Vet Cardiol ; 52: 43-60, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38428366

RESUMO

BACKGROUND: Many canine cardiac diseases are associated with left atrial (LA) remodeling and decreased function. For accurate assessment of LA indices, large-scale and prospectively determined reference intervals are necessary. OBJECTIVES: To generate reference intervals of LA size and function using two-dimensional and three-dimensional echocardiography. ANIMALS: Two hundred and one healthy adult dogs. METHODS: Left atrial volume was assessed in right parasternal long-axis, left apical four-chamber and two-chamber views using monoplane Simpson's method, two-dimensional and three-dimensional speckle tracking. Additionally, LA diameter was measured in right parasternal short-axis and long-axis views. Furthermore, LA function was determined by measuring strain and calculating LA fractional shortening and ejection fraction. All variables were tested for correlation to heart rate, age, and body weight. For LA diameter and volume, scaling exponents and prediction intervals were generated using allometric scaling. Reference intervals for LA function parameters were calculated using nonparametric methods. RESULTS: Left atrial diameter and volume showed a strong correlation with body weight. The scaling exponent for LA diameter was approximately 1/3 (0.34-0.40) and approximately one for volume measurements (0.97-1.26). Parameters of LA function showed no clinically relevant correlation with body weight, except for two variables, which showed a mild negative correlation. No clinically relevant correlations with age or heart rate were found. CONCLUSIONS: Reference intervals for linear, two-dimensional and three-dimensional measurements of LA size and function were established. The wide range of measurement methods offers the opportunity to select the appropriate reference values for LA evaluation depending on the available technical possibilities.


Assuntos
Função do Átrio Esquerdo , Ecocardiografia Tridimensional , Ecocardiografia , Átrios do Coração , Animais , Cães/anatomia & histologia , Valores de Referência , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/anatomia & histologia , Feminino , Ecocardiografia Tridimensional/veterinária , Ecocardiografia Tridimensional/métodos , Masculino , Ecocardiografia/veterinária , Função do Átrio Esquerdo/fisiologia
18.
Kardiologiia ; 64(2): 73-79, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38462807

RESUMO

AIM: Vitamin D deficiency has a high prevalence in the population and is highly associated with cardiovascular diseases. The aim of this study was to evaluate subclinical left ventricular (LV) function using strain analysis in healthy individuals with vitamin D deficiency. MATERIAL AND METHODS: 113 healthy volunteers were enrolled in the study (age, 44.1±7 yrs, 34 male). All volunteers underwent two-dimensional (2D) and three-dimensional (3D) speckle tracking echocardiography after conventional echocardiographic evaluation. The subjects were divided into two groups according to their vitamin D concentrations. 61 subjects with vitamin D less than 20 ng / ml were included in the vitamin D deficiency group. The baseline clinical characteristics, laboratory measurements, echocardiographic data, including 2D and 3D global longitudinal strain (GLS) values, were compared between the groups. RESULTS: The 2D GLS values of the subjects with vitamin D deficiency were lower (mathematically less negative) than subjects with normal vitamin D (-16.1±3.4 vs -19.3±4.2, p<0.001). Similarly, the 3D GLS results were lower in subjects with vitamin D deficiency (-18.3±5.2 vs -24.1±6.9, p<0.001). A significant correlation was detected between the vitamin D concentrations and the 2D and 3D GLS measurements. (r=0.765 and r=0.628, respectively, p<0.001). Vitamin D was found to be an independent predictor of impaired 2D and 3D LV GLS (p=0.031, p=0.023, respectively). CONCLUSION: Subclinical LV dysfunction in healthy individuals with vitamin D deficiency was demonstrated by 3D and 2D strain analysis. Due to potential negative effects of vitamin D deficiency on cardiac function, more attention should be paid to healthy individuals with vitamin D deficiency.


Assuntos
Ecocardiografia Tridimensional , Cardiopatias , Disfunção Ventricular Esquerda , Deficiência de Vitamina D , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Ecocardiografia Tridimensional/métodos , Ecocardiografia , Função Ventricular Esquerda , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Deficiência de Vitamina D/complicações , Deficiência de Vitamina D/diagnóstico , Vitamina D
19.
BMC Med Imaging ; 24(1): 61, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481130

RESUMO

OBJECTIVE: The paper aimed to improve the accuracy limitations of traditional two-dimensional ultrasound and surgical procedures in the diagnosis and management of congenital heart disease (chd), and to improve the diagnostic and therapeutic level of chd. METHOD: This article first collected patient data through real-time imaging and body surface probes, and then diagnosed 150 patients using three-dimensional echocardiography. In order to verify the effectiveness of the combination therapy, 60 confirmed patients were divided into a control group and an experimental group. The control group received conventional two-dimensional ultrasound and surgical treatment, while the experimental group received three-dimensional ultrasound and image guided surgical treatment. RESULT: In the second diagnosis, the diagnostic accuracy of type 1, type 2, and type 3 in the control group was 84.21%, 84.02%, and 83.38%, respectively. The diagnostic accuracy rates of type 1, type 2, and type 3 in the experimental group were 92.73%, 92.82%, and 92.83%, respectively. In the control group, 2 males and 1 female experienced heart failure after surgery. However, in the experimental group, 0 males and 0 females experienced heart failure after surgery. CONCLUSION: The combination of three-dimensional echocardiography and image guided surgery can improve diagnostic accuracy and surgical treatment effectiveness, thereby reducing risks and complications, and improving surgical success rate.


Assuntos
Ecocardiografia Tridimensional , Cardiopatias Congênitas , Insuficiência Cardíaca , Cirurgia Assistida por Computador , Masculino , Humanos , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ecocardiografia Tridimensional/métodos , Ultrassonografia
20.
Ultrasound Med Biol ; 50(5): 661-670, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38341361

RESUMO

OBJECTIVE: Valvular heart diseases (VHDs) pose a significant public health burden, and deciding the best treatment strategy necessitates accurate assessment of heart valve function. Transthoracic echocardiography (TTE) is the key modality to evaluate VHDs, but the lack of standardized quantitative measurements leads to subjective and time-consuming assessments. We aimed to use deep learning to automate the extraction of mitral valve (MV) leaflets and annular hinge points from echocardiograms of the MV, improving standardization and reducing workload in quantitative assessment of MV disease. METHODS: We annotated the MV leaflets and annulus points in 2931 images from 127 patients. We propose an approach for segmenting the annotated features using Attention UNet with deep supervision and weight scheduling of the attention coefficients to enforce saliency surrounding the MV. The derived segmentation masks were used to extract quantitative biomarkers for specific MV leaflet scallops throughout the heart cycle. RESULTS: Evaluation performance was summarized using a Dice score of 0.63 ± 0.14, annulus error of 3.64 ± 2.53 and leaflet angle error of 8.7 ± 8.3°. Leveraging Attention UNet with deep supervision robustness of clinically relevant metrics was improved compared with UNet, reducing standard deviations by 2.7° (angle error) and 0.73 mm (annulus error). We correctly identified cases of MV prolapse, cases of stenosis and healthy references from a clinical material using the derived biomarkers. CONCLUSION: Robust deep learning segmentation and tracking of MV morphology and motion is possible by leveraging attention gates and deep supervision, and holds promise for enhancing VHD diagnosis and treatment monitoring.


Assuntos
Aprendizado Profundo , Ecocardiografia Tridimensional , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Biomarcadores , Ecocardiografia Transesofagiana/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...