Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.309
Filtrar
2.
Bratisl Lek Listy ; 125(6): 347-353, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38757590

RESUMO

PURPOSE: Standard endovascular aortic aneurysm repair (EVAR) is sometimes the only treatment option for patients with hostile aortic neck anatomy, but it carries an increased risk of both early and late procedure-related complications. The aim of this study was to report on single-center experience with the Heli-FX EndoAnchors (Medtronic, Santa Rosa, CA) as an adjunctive procedure to endovascular aneurysm repair (EVAR) for prevention and perioperative treatment of proximal neck complications in patients with hostile neck anatomy.  MATERIALS AND METHODS: A single-centre, retrospective study evaluating 24 consecutive patients treated with EndoAnchors during the index EVAR procedure between November 2018 and August 2021. EndoAnchor implantation was indicated for cases with hostile proximal aortic neck anatomy characterised by the presence of at least one of the following parameters: length of 28 mm, angle of >60°, circumferential thrombus/calcification involving ≥50%, and reverse taper. RESULTS:  Median follow-up period was 22.5 months (IQR 2-31.5 months) with no aneurysm-related death, rupture, or conversion to open surgical repair during the follow-up. The procedural success rate was 100%, with no type Ia endoleak at the completion angiography. A mean of 7 EndoAnchors was used per patient (range 4-12). There were no EndoAnchor fractures and dislocations or stent graft fabric damage due to anchor implants. Twenty-three patients (95.8%) remained free of type Ia endoleak and migration on follow-up imaging. Aneurysm sac regression was observed in 13 patients (54.1%), while in 8 patients (33.3%) the sac remained stable. Sac enlargement was present in 1 patient (4.2%) due to late type Ia endoleak. Two patients were lost to the follow-up immediately after the procedure. Between two groups of patients (sac regression versus failure to regress), the larger initial diameter of the proximal neck was the only significant independent factor associated with a lower possibility of sac regression (p= 0,021). CONCLUSIONS:  The use of EndoAnchors during the index EVAR procedure in cases with challenging aortic neck anatomy with or without perioperative type Ia endoleak was associated with good midterm results and led to sac regression in most of the patients (Tab. 4, Fig. 3, Ref. 31).


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Procedimentos Endovasculares/métodos , Masculino , Estudos Retrospectivos , Feminino , Idoso , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/instrumentação , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/prevenção & controle , Endoleak/etiologia , Endoleak/prevenção & controle , Resultado do Tratamento , Prótese Vascular , Stents
3.
J Cardiothorac Surg ; 19(1): 210, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38616244

RESUMO

Bilateral isolated common iliac artery aneurysms (CIAAs) are rare, and endovascular repair of CIAAs has emerged as an alternative to traditional open surgical repair. The primary goal of therapy is to exclude the aneurysm sac while maintaining perfusion of at least one internal iliac artery (IIA) to prevent pelvic ischemia. Although the iliac branch device (IBD) has improved the feasibility of preserving the IIA, its applicability is limited to a specific subset of aneurysm anatomy. We present a case series of three patients with bilateral isolated CIAAs in whom preoperative CT scans revealed an absence of a landing zone, the diameter of proximal CIA diameter was less than 13.0 mm, and normal diameter of the nonaneurysmal infrarenal aorta, making it challenging to use an IBD alone or a standard bifurcated aortic endograft to provide a proximal landing zone for iliac artery stenting. To overcome the small diameter of the infrarenal aorta, we implanted an aortic bifurcated unibody endograft. Then, we utilized a balloon-expandable covered stent-graft with overdilation as a modified sandwich technique to create an "eye of the tiger" configuration to prevent gutter leakage. The final angiography performed during the procedure revealed successful exclusion of the aneurysms, with blood flow to the right IIA and no type III endoleak. During the postoperative follow-up period, no patients exhibited symptoms associated with pelvic ischemia. There were no endoleaks or sac expansions on the two-year follow-up CT scans, and all external and internal iliac graft limbs were patent. This study demonstrated that a combination of an aortic bifurcated unibody endograft and a modified sandwich technique can effectively treat bilateral isolated CIAAs with certain anatomical constraints.


Assuntos
Procedimentos Endovasculares , Aneurisma Ilíaco , Humanos , Artéria Ilíaca , Aneurisma Ilíaco/cirurgia , Angiografia , Endoleak , Isquemia
4.
J Cardiovasc Surg (Torino) ; 65(2): 106-109, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38635287

RESUMO

BACKGROUND: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms. METHODS: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected. The primary outcome measure was the freedom of a type Ia gutter-related endoleak at postoperative computed tomography angiography (CTA). Secondary outcome measures included early type Ia endoleak-related reinterventions, target vessel complications including dissection or loss of target vessel, major adverse events, and mortality. Continuous variables were presented as median (interquartile range [IQR]) and categorical variables as count and percentage. RESULTS: Ten patients were included in the present study. Eight (80%) were males, in nine cases a single chimney was implanted, and the other one was a double chimney graft placement. The treated aneurysms had an infrarenal neck length of 3.4 (1.2) mm. The rate of main body oversizing was 30%. The new neck length after chimney graft placement was 18 (3) mm. The median procedural time was 130 (17) mm, contrast medium use was 109 (26) mL, radiation time was 45 (12) min. The technical success was 100%. No type Ia endoleak was detected at the postoperative CTA. There were no target vessel issues. No major adverse events or death were observed. CONCLUSIONS: First reported cohort of patients treated with EnChEVAR demonstrated reproducible clinical and procedural outcomes within the 3 vascular centers with total exclusion of the aneurysms, patent renal arteries, and no evidence of gutter-related type IA endoleak. Further evidence with larger sample size of treated patients and longer follow-up are needed.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Endoleak , Procedimentos Endovasculares , Desenho de Prótese , Sistema de Registros , Humanos , Masculino , Feminino , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Idoso , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Endoleak/etiologia , Fatores de Tempo , Resultado do Tratamento , Idoso de 80 Anos ou mais , Stents , Estudos Retrospectivos , Fatores de Risco , Rotulagem de Produtos , Correção Endovascular de Aneurisma
5.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38439540

RESUMO

OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) for aortic arch aneurysms is challenging because of anatomical restrictions and the presence of cervical branches. Revascularization of the cervical branch is required when conventional commercial stent grafts are used. TEVAR using fenestrated stent grafts (FSG) often does not require additional procedures to revascularize cervical branches. This study aimed to evaluate the features and initial and midterm outcomes of TEVAR using fenestrated stent grafts. METHODS: From April 2007 to December 2016, 101 consecutive patients underwent TEVAR using fenestrated stent grafts for distal aortic arch aneurysms at a single centre. Technical success, complications, freedom from aneurysm-related death, secondary intervention and aneurysm progression were retrospectively investigated. RESULTS: All the patients underwent TEVAR using fenestrated stent grafts. The 30-day mortality rate was zero. Cerebral infarction, access route problems and spinal cord injury occurred in 4, 3 and 2 patients, respectively. Each type of endoleak was observed in 38 of the 101 patients during the course of the study; 20/38 patients had minor type 1 endoleaks at the time of discharge. The endoleak disappeared in 2 patients and showed no significant change in 8 patients; however, the aneurysm expanded over time in 10 patients. Additional treatment was performed in 8 of the 10 patients with type 1 endoleaks and dilatation of the aneurysm. The rate of freedom from aneurysm-related death during the observation period was 98%. CONCLUSIONS: TEVAR with FSG is a simple procedure, with few complications. Additional treatment has been observed to reduce aneurysm-related deaths, even in patients with endoleaks and enlarged aneurysms. Based on this study, the outcomes of endovascular repair of aortic arch aneurysms using a fenestrated stent graft seem acceptable.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular , Correção Endovascular de Aneurisma , Endoleak/etiologia , Stents , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Fatores de Tempo , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia
6.
Expert Rev Med Devices ; 21(3): 165-177, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38431273

RESUMO

INTRODUCTION: With the incidence of thoracic aortic disease on the rise, total arch replacement (TAR) with frozen elephant trunk (FET) remains the gold-standard management strategy due to optimal results. Several FET devices exist commercially on the global market. However, the mainstay and most commonly used and reported device is the Thoraflex Hybrid Prosthesis (THP), with several recent reports suggesting its superiority. AREAS COVERED: This review aims to collate and summarize the evidence in the literature on the clinical outcomes of TAR with FET using THP, with a focus on mortality, neurological complications, endoleak, distal stent-induced new entry (dSINE), aortic remodeling, coagulopathy, and graft kinking. In addition, the design features of THP is discussed, and an overview of market competitors is also highlighted. EXPERT OPINION: THP consistently demonstrates its effectiveness in treating complex thoracic aortic pathology through favorable clinical outcomes, which can be attributed to its unique and innovative design. Rates of early mortality ranged 0.6-14.2%, neurological complications 0-25%, endoleak 0-8.4% and dSINE 0-14.5%, with minimal incidence of graft kinking and coagulopathy. Aortic remodeling is favorable and comparable to competitors. All this evidence solidifies THP as the leading FET device, particularly when combined with appropriate patient selection and surgical planning.


Assuntos
Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Prótese Vascular , Endoleak/cirurgia , Stents , Aorta Torácica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
7.
Radiol Cardiothorac Imaging ; 6(2): e230217, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451189

RESUMO

Purpose To compare image quality, diagnostic performance, and conspicuity between single-energy and multi-energy images for endoleak detection at CT angiography (CTA) after endovascular aortic repair (EVAR). Materials and Methods In this single-center prospective randomized controlled trial, individuals undergoing CTA after EVAR between August 2020 and May 2022 were allocated to imaging using either low-kilovolt single-energy images (SEI; 80 kV, group A) or low-kiloelectron volt virtual monoenergetic images (VMI) at 40 and 50 keV from multi-energy CT (80/Sn150 kV, group B). Scan protocols were dose matched (volume CT dose index: mean, 4.5 mGy ± 1.8 [SD] vs 4.7 mGy ± 1.3, P = .41). Contrast-to-noise ratio (CNR) was measured. Two expert radiologists established the reference standard for the presence of endoleaks. Detection and conspicuity of endoleaks and subjective image quality were assessed by two different blinded radiologists. Interreader agreement was calculated. Nonparametric statistical tests were used. Results A total of 125 participants (mean age, 76 years ± 8; 103 men) were allocated to groups A (n = 64) and B (n = 61). CNR was significantly lower for 40-keV VMI (mean, 19.1; P = .048) and 50-keV VMI (mean, 16.8; P < .001) as compared with SEI (mean, 22.2). In total, 45 endoleaks were present (A: 23 vs B: 22). Sensitivity for endoleak detection was higher for SEI (82.6%, 19 of 23; P = .88) and 50-keV VMI (81.8%, 18 of 22; P = .90) as compared with 40-keV VMI (77.3%, 17 of 22). Specificity was comparable among groups (SEI: 92.7%, 38 of 41; both VMI energies: 92.3%, 35 of 38; P = .99), with an interreader agreement of 1. Conspicuity of endoleaks was comparable between SEI (median, 2.99) and VMI (both energies: median, 2.87; P = .04). Overall subjective image quality was rated significantly higher for SEI (median, 4 [IQR, 4-4) as compared with 40 and 50 keV (both energies: median, 4 [IQR, 3-4]; P < .001). Conclusion SEI demonstrated higher image quality and comparable diagnostic accuracy as compared with 50-keV VMI for endoleak detection at CTA after EVAR. Keywords: Aneurysms, CT, CT Angiography, Vascular, Aorta, Technology Assessment, Multidetector CT, Abdominal Aortic Aneurysms, Endoleaks, Perigraft Leak Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Angiografia por Tomografia Computadorizada , Endoleak , Idoso , Humanos , Masculino , Aorta , Endoleak/diagnóstico por imagem , Fenômenos Físicos , Estudos Prospectivos , Feminino
8.
Kyobu Geka ; 77(2): 136-139, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459863

RESUMO

A 67-year-old male was admitted to our hospital for sudden onset chest pain and hoarseness. He underwent 2-debranching thoracic endovascular aortic repair for a ruptured aortic arch aneurysm four years prior. However, computed tomography (CT) revealed an aneurysmal rerupture due to a typeⅠa endoleak. We performed partial arch replacement with uncovered stent removal under intermittent hypothermic circulatory arrest. We needed to be more careful than usual open heart surgery because a non-anatomical bypass procedure was performed. The surgery was successful without any major complications, and the patient was discharged on the 23th postoperative day. Reinterventions post-endovascular repair are sometimes difficult;thus, open surgery could be useful for arch replacement.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Correção Endovascular de Aneurisma , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Resultado do Tratamento , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Estudos Retrospectivos
9.
J Vasc Interv Radiol ; 35(6): 874-882, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38479451

RESUMO

PURPOSE: To evaluate the effectiveness and safety of pre-emptive transcatheter arterial embolization (P-TAE) for aortic side branches (ASBs) to prevent Type 2 endoleaks (EL2) before endovascular aneurysm repair (EVAR) using the Excluder stent-graft system (Excluder). MATERIALS AND METHODS: In this prospective, multicenter study, 80 patients (mean age, 79.1 years [SD ± 6.7]; 85.0% were men; mean aneurysmal sac diameter, 48.4 mm [SD ± 7.4]) meeting the eligibility criteria were prospectively enrolled from 9 hospitals. Before EVAR, P-TAE was performed to embolize the patent ASBs originating from the abdominal aortic aneurysm. Contrast-enhanced computed tomography (CT) was performed at 1 month and 6 months after EVAR. The primary endpoint was EL2 incidence at 6 months, and the secondary endpoints were aneurysmal sac diameter changes at 6 and 12 months, P-TAE outcomes, adverse events related to P-TAE, reintervention, and aneurysm-related mortality. RESULTS: All patients successfully underwent P-TAE without serious. Coil embolization was successful in 81.6% of ASBs. EL2 incidence at 6 months was identified in 18 of 70 (25.7%) patients. Aneurysmal sac diameter shrinkage (≥5 mm) was observed in 30.0% of patients at 6 months and in 40.9% at 12 months. Only 1 patient required reintervention for EL2 within 1 year of EVAR; aneurysm-related deaths were not observed. CONCLUSIONS: P-TAE for ASBs before EVAR using Excluder is a safe and effective strategy. It aids in achieving early aneurysmal sac shrinkage and reduces EL2 reintervention at 1 year after EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Angiografia por Tomografia Computadorizada , Embolização Terapêutica , Endoleak , Procedimentos Endovasculares , Desenho de Prótese , Stents , Humanos , Feminino , Masculino , Idoso , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Estudos Prospectivos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Resultado do Tratamento , Idoso de 80 Anos ou mais , Endoleak/etiologia , Endoleak/terapia , Endoleak/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Fatores de Tempo , Aortografia , Fatores de Risco , Japão , Correção Endovascular de Aneurisma
11.
J Cardiovasc Surg (Torino) ; 65(2): 99-105, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38551514

RESUMO

The initial success and widespread adoption of endovascular aneurysm repair (EVAR) for the treatment of abdominal aortic aneurysms have been tempered by numerous reports of secondary interventions and increased long-term mortality compared with open repair. Over the past decade, several studies on postoperative sac dynamics after EVAR have suggested that the presence of sac regression is a benign feature with a favorable prognosis. Conversely, increasing sacs and even stable sacs can be indicators of more unstable sac behavior with worse outcomes in the long-term. Endoleaks were initially perceived as the main drivers of sac behavior. However, the observation that sac regression can occur in the presence of endoleaks, and vice versa - increasing sacs without evidence of endoleak - on imaging studies, suggests the involvement of other contributing factors. These factors can be divided into anatomical factors, patient characteristics, sac thrombus composition, and device-related factors. The shift of interest away from especially type 2 endoleaks is further supported by promising results with the use of EndoAnchors regarding postoperative sac behavior. This review provides an overview of the existing literature on the implications and known risk factors of post-EVAR sac behavior, describes the accurate measurement of sac behavior, and discusses the use of EndoAnchors to promote sac regression.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Endoleak , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Endoleak/etiologia , Fatores de Risco , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Desenho de Prótese
12.
J Cardiothorac Surg ; 19(1): 57, 2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38311778

RESUMO

PURPOSE: To evaluate the efficacy and safety of selective aneurysmal sac neck-targeted embolization in endovascular aneurysm repair (EVAR) in patients with a hostile neck anatomy (HNA). MATERIALS AND METHODS: Between October 2020 and June 2022, patients with an abdominal aortic aneurysm (AAA) and HNA who underwent EVAR with a low-profile stent graft and a selective aneurysmal sac neck-targeted embolization technique were analysed. An HNA was defined by the presence of any of the following parameters: infrarenal neck angulation > 60°; neck length < 15 mm; conical neck; circumferential calcification ≥ 50%; or thrombus ≥ 50%. Before occluding the entire aneurysm during the procedure, a buddy wire was loaded prophylactically into the sac through the contralateral limb side. If a type Ia endoleak (ELIa) occurred and persisted despite adjunctive treatment such as balloon moulding or cuff extension, this preloaded wire could be utilized to enable a catheter to reach the space between the stent graft and sac neck to perform coil embolization. In the absence of ELIa, the wire was simply retracted. The primary outcome of this study was freedom from sac expansion and endoleak-related reintervention during the follow-up period; secondary outcomes included technical success and intraoperative and in-hospital postoperative complications. RESULTS: Among the 28 patients with a hostile neck morphology, 11 (39.5%) who presented with ELIa underwent intraprocedural treatment involving sac neck-targeted detachable coil embolization. Seventeen individuals (60.7%) of the total patient population did not undergo coiling. All patients in the coiling group underwent balloon moulding, and 2 patients additionally underwent cuff extension. In the noncoiling group, 14 individuals underwent balloon moulding as a treatment for ELIa, while 3 patients did not exhibit ELIa during the procedure. The coiling group showed longer operating durations (81.27 ± 11.61 vs. 70.71 ± 7.17 min, P < 0.01) and greater contrast utilization than the noncoiling group (177.45 ± 52.41 vs. 108.24 ± 17.49 ml, P < 0.01). In the entire cohort, the technical success rate was 100%, and there were no procedure-related complications. At a mean follow-up of 18.6 ± 5.2 months (range 12-31), there were no cases of sac expansion (19 cases of sac regression, 67.86%; 9 cases of stability, 32.14%) or endoleak-related reintervention. CONCLUSIONS: Selective aneurysmal sac neck-targeted embolization for the treatment of ELIa in AAA patients with an HNA undergoing EVAR is safe and may prevent type Ia endoleak and related sac expansion after EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Endoleak/etiologia , Implante de Prótese Vascular/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Stents/efeitos adversos
13.
Ann Vasc Surg ; 102: 9-16, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38301847

RESUMO

BACKGROUND: Endoleaks are the most common complication after endovascular aneurysm repair (EVAR). Computed tomography angiography (CTA) is presently the golden standard for lifelong surveillance after EVAR. Several studies and meta-analyses have shown contrast-enhanced ultrasound (CEUS) to be a good alternative. The main goal of our study was to further validate the inclusion of CEUS in follow-up examination protocols for the systematic surveillance after EVAR. METHODS: A retrospective analysis of patients who had received CEUS as part of their routine surveillance after EVAR at our center was conducted. Detection rate and classification of endoleak types were compared between available postinterventional CTA/magnetic resonance angiography and follow-up CEUS examinations. Last preinterventional CTAs before EVAR served as baselines with focus on potential cofactors such as age, body mass index, maximum aortic aneurysm diameters, endoleak orientation, and distance-to-surface influencing detection rates and classification. RESULTS: In total, 101 patients were included in the analysis. Forty-four endoleaks (43.5% of cases) were detected by either initial CEUS or CTA, mostly type II (37.6% of the included patients). Initial CEUS showed an endoleak sensitivity of 91.2%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 84.6%. No covariate with an influence on the correct classification could be identified either for CEUS or CT. CONCLUSIONS: CEUS should be considered a valid complementary method to CTA in the lifelong surveillance after EVAR. As type II endoleaks seem to be a common early-term, sometimes spontaneously resolving complication that can potentially be missed by CTA, we suggest combined follow-up protocols including CEUS in the early on postinterventional assessment.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Meios de Contraste , Correção Endovascular de Aneurisma , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Seguimentos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Aortografia/métodos , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Tomografia Computadorizada por Raios X
14.
Ann Vasc Surg ; 102: 64-73, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38301848

RESUMO

BACKGROUND: Local anesthesia (LA) is sparsely used in endovascular aneurysm repair (EVAR) despite short-term benefit, likely secondary to concerns over patient movement preventing accurate endograft deployment. The objective of this study is to examine the association between anesthesia type and endoleak, sac regression, reintervention, and mortality. METHODS: The Vascular Quality Initiative database was queried for all EVAR cases from 2014 to 2022. Patients were included if they underwent percutaneous elective EVAR with anatomical criteria within instructions for use of commercially approved endografts. Multivariable logistic regression with propensity score weighting was used to determine the association between anesthesia type on the risk of any endoleak noted by intraoperative completion angiogram and sac regression. Multivariable survival analysis with propensity score weighting was used to determine the association between anesthesia type and endoleak at 1 year, long-term reintervention, and mortality. RESULTS: Thirteen thousand nine hundred thirty two EVARs met inclusion criteria: 1,075 (8%) LA and 12,857 (92%) general anesthesia (GA). On completion angiogram, LA was associated with fewer rates of any endoleaks overall (16% vs. 24%, P < 0.001). On multivariable analysis with propensity score weighting, LA was associated with similar adjusted odds of any endoleak on intraoperative completion angiogram (odds ratio [OR] 0.56, 95% confidence interval [CI] 0.47-0.68) as well as combined type 1a and type 1b endoleaks (OR 0.72, 95% CI 0.47-1.09). Follow-up computed tomography imaging at 1 year was available for 4,892 patients, 377 (8%) LA and 4,515 (92%) GA. At 1 year, LA was associated with similar rate of freedom from any endoleaks compared to GA (0.66 [95% CI 0.63-0.69] vs. 0.71 [95% CI 0.70-0.72], P = 0.663) and increased rates of sac regression (50% vs. 45%, P = 0.040). On multivariable analysis with propensity score weighting, LA and GA were associated with similar adjusted odds of sac regression (OR 1.22, 95% CI 0.97-1.55). LA and GA had similar rates of endoleak at 1 year (hazard ratio [HR] 0.14, 95% CI 0.63-1.07); however, LA was associated with decreased hazards of combined type 1a and 1b endoleaks at 1 year (HR 0.87, 95% CI 0.80-0.96). LA and GA had similar adjusted long-term reintervention rate (HR 0.77, 95% CI 0.44-1.38) and long-term mortality (HR 1.100, 95% CI 079-1.25). CONCLUSIONS: LA is not associated with increased adjusted rates of any endoleak on completion angiogram or at 1-year follow-up compared to GA. LA is associated with decreased adjusted rates of type 1a and type 1b endoleak at 1 year, but similar rates of sac regression, long-term reintervention, and mortality. Concerns for accurate graft deployment should not preclude use of LA and LA should be increasingly considered when deciding on anesthetic type for standard elective EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Anestesia Local/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Fatores de Risco , Resultado do Tratamento , Aortografia/métodos , Estudos Retrospectivos
15.
J Surg Res ; 296: 516-522, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38330677

RESUMO

INTRODUCTION: Recent data suggests that infrarenal abdominal aortic aneurysm (AAA) endovascular repair (EVAR) with large diameter grafts (LGs) may have a higher risk of endoleak and reintervention. However, this has not been studied extensively for fenestrated endovascular aneurysm repair (fEVAR). We, therefore, sought to evaluate the outcomes of patients undergoing fEVAR with large-diameter endografts. METHODS: Patients from the national Vascular Quality Initiative registry who underwent fEVAR for intact juxtarenal AAA were identified. Patients with genetic causes for aneurysms, those with prior aortic surgery, and those undergoing repair for symptomatic or ruptured aneurysms were excluded. Rates of endoleaks and reintervention at periprocedural and long-term follow-up timepoints (9-22 mo) were analyzed in grafts 32 mm or larger (LG) and were compared to those smaller than 32 mm (small diameter graft). RESULTS: A total of 693 patients (22.8% LG) were identified. Overall, demographic variables were comparable except LG exhibited a more frequent history of coronary artery disease (32.9% versus 25.4%, P = 0.037). There were no significant differences in the rates of endoleak at procedural completion. Overall survival at 5 y was no different. The rate of reintervention at 1 y was also no different (log-rank P = 0.86). CONCLUSIONS: While graft size appears to have an association with outcomes in infrarenal aneurysm repair, the same does not appear to be true for fEVAR. Further studies should evaluate the long-term outcomes associated with LG which could alter the approach to repair of AAA with large neck diameters traditionally treated with standard infrarenal EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Endoleak/cirurgia , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese
16.
Sci Rep ; 14(1): 3845, 2024 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-38360941

RESUMO

To assess the image quality parameters of dual-energy computed tomography angiography (DECTA) 40-, and 60 keV virtual monoenergetic images (VMIs) combined with deep learning-based image reconstruction model (DLM) and iterative reconstructions (IR). CT scans of 28 post EVAR patients were enrolled. The 60 s delayed phase of DECTA was evaluated. Objective [noise, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR)] and subjective (overall image quality and endoleak conspicuity - 3 blinded readers assessment) image quality analyses were performed. The following reconstructions were evaluated: VMI 40, 60 keV VMI; IR VMI 40, 60 keV; DLM VMI 40, 60 keV. The noise level of the DLM VMI images was approximately 50% lower than that of VMI reconstruction. The highest CNR and SNR values were measured in VMI DLM images. The mean CNR in endoleak in 40 keV was accounted for as 1.83 ± 1.2; 2.07 ± 2.02; 3.6 ± 3.26 in VMI, VMI IR, and VMI DLM, respectively. The DLM algorithm significantly reduced noise and increased lesion conspicuity, resulting in higher objective and subjective image quality compared to other reconstruction techniques. The application of DLM algorithms to low-energy VMIs significantly enhances the diagnostic value of DECTA in evaluating endoleaks. DLM reconstructions surpass traditional VMIs and IR in terms of image quality.


Assuntos
Endoleak , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Endoleak/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Razão Sinal-Ruído
17.
Eur J Vasc Endovasc Surg ; 67(6): 895-902, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38320646

RESUMO

OBJECTIVE: Iliac branch devices (IBDs) have shown good results but there is little evidence for the risk of internal iliac artery (IIA) endoleak, so there are no clear recommendations on the maximum diameter it should be. Based on limited evidence, it was hypothesised that an IIA of ≥ 11 mm in diameter presents an increased risk of type Ic endoleak. METHODS: This was a single centre, retrospective case control study. Patients undergoing an IBD with the main trunk of the IIA as the target vessel, between 2015 and 2021, were identified. Two groups were created: those with a main trunk diameter of < 11 mm; and those with a diameter of ≥ 11 mm. Technical success, freedom from type Ic endoleak, and re-intervention rates were compared. A receiver operating characteristic (ROC) curve was performed to show a cutoff IIA diameter value for risk of type Ic endoleak. Multivariate analysis was performed to assess the risk of type Ic endoleak and the presence of calcification, stenosis, and landing zone length in the IIA. RESULTS: There were 182 IBDs identified. The dilated IIA group (54 IBDs) had significantly lower technical success (91% vs. 98.4%; p = .002), lower freedom from type Ic endoleak (77% vs. 97.1% at 24 months; p = .001), and lower freedom from re-interventions (70% vs. 92.4% at 24 months; p = .002). The ROC curve showed that 10.5 mm was the cutoff diameter for type Ic endoleak. Moderate or severe calcification as well as landing zone length < 5 mm also correlated with type Ic endoleak. CONCLUSION: IBDs have a statistically significantly higher rate of technical failure, lower freedom from type Ic endoleak, and lower freedom from re-intervention when the IIA is ≥ 11 mm in diameter.


Assuntos
Implante de Prótese Vascular , Endoleak , Procedimentos Endovasculares , Artéria Ilíaca , Humanos , Endoleak/etiologia , Estudos Retrospectivos , Masculino , Feminino , Idoso , Artéria Ilíaca/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Fatores de Risco , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Idoso de 80 Anos ou mais , Prótese Vascular , Medição de Risco , Resultado do Tratamento , Estudos de Casos e Controles , Dilatação Patológica , Desenho de Prótese , Pessoa de Meia-Idade , Stents/efeitos adversos
18.
Ann Vasc Surg ; 103: 122-132, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38387799

RESUMO

BACKGROUND: In endovascular aortic repair (EVAR), preemptive embolization of sac branch vessels is effective in preventing postoperative type II endoleak (T2EL). However, this technique has not been widely adopted especially for lumbar arteries (LAs) because of technical difficulties and time constraints. This study aimed to investigate the efficacy of nonselective sac coil embolization, which is a simpler surgical method, in postoperative sac shrinkage for patients at a high risk of T2EL from LAs. METHODS: We retrospectively assessed 76 patients who underwent elective EVAR for abdominal aortic aneurysm with 4 or more patent LAs or at least 1 patent LA of ≥2 mm at our hospital between January 2014 and December 2022. The patients who underwent sac coil embolization were included in Group Ⅰ (n = 20), and the others were divided into 2 groups: those with an inferior mesenteric artery that was originally occluded or embolized by coils or stent graft bodies (Group Ⅱ, n = 21), and those without that (Group Ⅲ, n = 35). In Group Ⅰ, 0.035-inch coils were inserted into the sac after complete stent graft deployment. The cumulative incidence of sac shrinkage (≥5 mm) was compared between the groups. Further, univariable and multivariable Cox regression analyses were used to determine the predictors of sac shrinkage. RESULTS: Sac shrinkage (≥5 mm) was observed more frequently in Group Ⅰ (50%) than in Group Ⅱ (19%) and Group Ⅲ (17%) (P = 0.052 and 0.043, respectively). The cumulative incidence of sac shrinkage was significantly higher in Group Ⅰ than in Group Ⅱ (log-rank P = 0.039) and Group Ⅲ (log-rank P = 0.024). Multivariable Cox regression analyses revealed that sac embolization was a significant predictor of sac shrinkage (hazard ratio, 4.23; 95% confidence interval, 1.66-10.8; P = 0.003). CONCLUSIONS: Nonselective sac coil embolization in EVAR is potentially effective for sac shrinkage in the early postoperative phase in patients at high risk of T2EL from LAs. This simple procedure may improve prognosis after EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Endoleak , Procedimentos Endovasculares , Humanos , Endoleak/etiologia , Endoleak/prevenção & controle , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Masculino , Estudos Retrospectivos , Embolização Terapêutica/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Idoso , Feminino , Fatores de Risco , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Resultado do Tratamento , Idoso de 80 Anos ou mais , Fatores de Tempo , Medição de Risco , Prótese Vascular , Stents , Correção Endovascular de Aneurisma
19.
J Vasc Surg ; 79(6): 1369-1378, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38316346

RESUMO

OBJECTIVE: There are a variety of methods used today to treat common iliac aneurysms with endovascular techniques. Of these approaches, little is known about whether a particular limb strategy influences endoleak, reintervention, or aneurysm regression rates. We present 5-year data comparing endoleak, stent graft migration, fracture, aneurysm sac dynamics, and aortic rupture rates among patients treated with bell bottom limbs (BB), iliac branch endoprosthesis (IBE), and coil and cover (CC) approaches from the Global Registry for Endovascular Aortic Treatment registry. Secondary end points were all-cause mortality, stroke, reintervention, and paraplegia. METHODS: Subjects from the GORE Global Registry for Endovascular Aortic Treatment were enrolled over a 5-year period from October 2017 to August 2022. We included 924 subjects in this study. Statistical data was generated on R software and limb groups were compared using the Pearson's χ2 test and the Kruskal-Wallis rank-sum test. RESULTS: We found no statistical difference in endoleak rates, stent graft migration, fracture, or aortic rupture when stratified by limb strategy. There was no difference between limb approaches with regard to aneurysm sac dynamics among those with abdominal aortic aneurysms and common iliac aneurysms. Similarly, no statistical difference between limb strategies was found in all-cause mortality, stroke, paraplegia, or reintervention rates. Among patients that required an additional graft during reintervention, the highest rates were found within the IBE group 8.6%, compared with BB group 2.2% and CC group 1.3% (P = .006). CONCLUSIONS: Overall, there was no difference among limb strategies in endoleak rates, stent graft migration, aneurysm sac dynamics, aortic rupture rates, or our secondary end points. Increased rates of reintervention requiring an additional graft within the IBE group is noteworthy and must be weighed against the adverse effects of hypogastric sacrifice with the CC approach or potentially less advantageous seal zones in the BB approach. This finding suggests that all limb approaches have equivalent effectiveness in managing the aneurysmal common iliac artery; thus, the choice of limb strategy should be individualized and remain at physician discretion. Future research should include a more robust sample size to reproduce these findings.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Desenho de Prótese , Sistema de Registros , Stents , Humanos , Aneurisma Ilíaco/cirurgia , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Masculino , Feminino , Resultado do Tratamento , Fatores de Tempo , Idoso , Fatores de Risco , Endoleak/etiologia , Endoleak/cirurgia , Idoso de 80 Anos ou mais , Ruptura Aórtica/cirurgia , Ruptura Aórtica/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Falha de Prótese , Estudos Retrospectivos , Medição de Risco , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Migração de Corpo Estranho/etiologia
20.
Cardiovasc Intervent Radiol ; 47(2): 161-176, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38216742

RESUMO

BACKGROUND: Endoleaks represent the most common complication after EVAR. Some types are associated with ongoing risk of aneurysm rupture and necessitate long-term surveillance and secondary interventions. PURPOSE: This document, as with all CIRSE Standards of Practice documents, will recommend a reasonable approach to best practices of managing endoleaks. This will include imaging diagnosis, surveillance, indications for intervention, endovascular treatments and their outcomes. Our purpose is to provide recommendations based on up-to-date evidence, updating the guidelines previously published on this topic in 2013. METHODS: The writing group was established by the CIRSE Standards of Practice Committee and consisted of clinicians with internationally recognised expertise in endoleak management. The writing group reviewed the existing literature performing a pragmatic evidence search using PubMed to select publications in English and relating to human subjects up to 2023. The final recommendations were formulated through consensus. RESULTS: Endoleaks may compromise durability of the aortic repair, and long-term imaging surveillance is necessary for early detection and correct classification to guide potential re-intervention. The majority of endoleaks that require treatment can be managed using endovascular techniques. This Standards of Practice document provides up-to-date recommendations for the safe management of endoleaks.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Endoleak/diagnóstico por imagem , Endoleak/terapia , Endoleak/etiologia , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Fatores de Risco , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...