Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.146
Filtrar
1.
Biomed Eng Online ; 23(1): 51, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38835079

RESUMO

BACKGROUND: Functional electrical stimulation (FES) is a rehabilitation technique that enables functional improvements in patients with motor control impairments. This study presents an original design and prototyping method for a smart sleeve for FES applications. The article explains how to integrate a carbon-based dry electrode into a textile structure and ensure an electrical connection between the electrodes and the stimulator for effective delivery of the FES. It also describes the materials and the step-by-step manufacturing processes. RESULTS: The carbon-based dry electrode is integrated into the textile substrate by a thermal compression molding process on an embroidered conductive matrix. This matrix is composed of textile silver-plated conductive yarns and is linked to the stimulator. Besides ensuring the electrical connection, the matrix improves the fixation between the textile substrate and the electrode. The stimulation intensity, the perceived comfort and the muscle torque generated by the smart FES sleeve were compared to hydrogel electrodes. The results show a better average comfort and a higher average stimulation intensity with the smart FES sleeve, while there were no significant differences for the muscle torque generated. CONCLUSIONS: The integration of the proposed dry electrodes into a textile is a viable solution. The wearable FES system does not negatively impact the electrodes' performance, and tends to improve it. Additionally, the proposed prototyping method is applicable to an entire garment in order to target all muscles. Moreover, the process is feasible for industrial production and commercialization since all materials and processes used are already available on the market.


Assuntos
Eletrodos , Têxteis , Humanos , Estimulação Elétrica/instrumentação , Desenho de Equipamento , Masculino , Adulto , Condutividade Elétrica , Carbono/química , Torque
2.
J Neural Eng ; 21(3)2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38862007

RESUMO

Objective.Electrodes chronically implanted in the brain undergo complex changes over time that can lower the signal to noise ratio (SNR) of recorded signals and reduce the amount of energy delivered to the tissue during therapeutic stimulation, both of which are relevant for the development of robust, closed-loop control systems. Several factors have been identified that link changes in the electrode-tissue interface (ETI) to increased impedance and degraded performance in micro- and macro-electrodes. Previous studies have demonstrated that brief pulses applied every few days can restore SNR to near baseline levels during microelectrode recordings in rodents, a process referred to as electrical rejuvenation. However, electrical rejuvenation has not been tested in clinically relevant macroelectrode designs in large animal models, which could serve as preliminary data for translation of this technique. Here, several variations of this approach were tested to characterize parameters for optimization.Approach. Alternating-current (AC) and direct-current (DC) electrical rejuvenation methods were explored in three electrode types, chronically implanted in two adult male nonhuman primates (NHP) (Macaca mulatta), which included epidural electrocorticography (ECoG) electrodes and penetrating deep-brain stimulation (DBS) electrodes. Electrochemical impedance spectroscopy (EIS) was performed before and after each rejuvenation paradigm as a gold standard measure of impedance, as well as at subsequent intervals to longitudinally track the evolution of the ETI. Stochastic error modeling was performed to assess the standard deviation of the impedance data, and consistency with the Kramers-Kronig relations was assessed to evaluate the stationarity of EIS measurement.Main results. AC and DC rejuvenation were found to quickly reduce impedance and minimize the tissue component of the ETI on all three electrode types, with DC and low-frequency AC producing the largest impedance drops and reduction of the tissue component in Nyquist plots. The effects of a single rejuvenation session were found to last from several days to over 1 week, and all rejuvenation pulses induced no observable changes to the animals' behavior.Significance. These results demonstrate the effectiveness of electrical rejuvenation for diminishing the impact of chronic ETI changes in NHP with clinically relevant macroelectrode designs.


Assuntos
Eletrodos Implantados , Macaca mulatta , Animais , Masculino , Impedância Elétrica , Microeletrodos , Estimulação Elétrica/métodos , Estimulação Elétrica/instrumentação , Razão Sinal-Ruído
3.
J Neural Eng ; 21(4)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38885680

RESUMO

Objective.The wireless transfer of power for driving implantable neural stimulation devices has garnered significant attention in the bioelectronics field. This study explores the potential of photovoltaic (PV) power transfer, utilizing tissue-penetrating deep-red light-a novel and promising approach that has received less attention compared to traditional induction or ultrasound techniques. Our objective is to critically assess key parameters for directly powering neurostimulation electrodes with PVs, converting light impulses into neurostimulation currents.Approach.We systematically investigate varying PV cell size, optional series configurations, and coupling with microelectrodes fabricated from a range of materials such as Pt, TiN, IrOx, Ti, W, PtOx, Au, or poly(3,4 ethylenedioxythiophene):poly(styrene sulfonate). Additionally, two types of PVs, ultrathin organic PVs and monocrystalline silicon PVs, are compared. These combinations are employed to drive pairs of electrodes with different sizes and impedances. The readout method involves measuring electrolytic current using a straightforward amplifier circuit.Main results.Optimal PV selection is crucial, necessitating sufficiently large PV cells to generate the desired photocurrent. Arranging PVs in series is essential to produce the appropriate voltage for driving current across electrode/electrolyte impedances. By carefully choosing the PV arrangement and electrode type, it becomes possible to emulate electrical stimulation protocols in terms of charge and frequency. An important consideration is whether the circuit is photovoltage-limited or photocurrent-limited. High charge-injection capacity electrodes made from pseudo-faradaic materials impose a photocurrent limit, while more capacitive materials like Pt are photovoltage-limited. Although organic PVs exhibit lower efficiency than silicon PVs, in many practical scenarios, stimulation current is primarily limited by the electrodes rather than the PV driver, leading to potential parity between the two types.Significance.This study provides a foundational guide for designing a PV-powered neurostimulation circuit. The insights gained are applicable to bothin vitroandin vivoapplications, offering a resource to the neural engineering community.


Assuntos
Eletrodos Implantados , Microeletrodos , Desenho de Equipamento/métodos , Neuroestimuladores Implantáveis , Estimulação Elétrica/métodos , Estimulação Elétrica/instrumentação
4.
J Neural Eng ; 21(3)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38776894

RESUMO

Objective.Electrical stimulation of peripheral nerves has long been a treatment option to restore impaired neural functions that cannot be restored by conventional pharmacological therapies. Endovascular neurostimulation with stent-mounted electrode arrays is a promising and less invasive alternative to traditional implanted electrodes, which typically require invasive implantation surgery. In this study, we investigated the feasibility of endovascular stimulation of the femoral nerve using a stent-mounted electrode array and compared its performance to that of a commercially available pacing catheter.Approach.In acute animal experiments, a pacing catheter was implanted unilaterally in the femoral artery to stimulate the femoral nerve in a bipolar configuration. Electromyogram of the quadriceps and electroneurogram of a distal branch of the femoral nerve were recorded. After retrieval of the pacing catheter, a bipolar stent-mounted electrode array was implanted in the same artery and the recording sessions were repeated.Main Results.Stimulation of the femoral nerve was feasible with the stent-electrode array. Although the threshold stimulus intensities required with the stent-mounted electrode array (at 100-500µs increasing pulse width, 2.17 ± 0.87 mA-1.00 ± 0.11 mA) were more than two times higher than the pacing catheter electrodes (1.05 ± 0.48 mA-0.57 ± 0.28 mA), we demonstrated that, by reducing the stimulus pulse width to 100µs, the threshold charge per phase and charge density can be reduced to 0.22 ± 0.09µC and 24.62 ± 9.81µC cm-2, which were below the tissue-damaging limit, as defined by the Shannon criteria.Significance.The present study is the first to reportin vivofeasibility and efficiency of peripheral nerve stimulation using an endovascular stent-mounted electrode array.


Assuntos
Eletrodos Implantados , Estudos de Viabilidade , Nervo Femoral , Stents , Nervo Femoral/fisiologia , Animais , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Estimulação Elétrica/métodos , Estimulação Elétrica/instrumentação , Masculino , Eletromiografia/métodos
5.
J Neurosci Methods ; 408: 110169, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38782123

RESUMO

BACKGROUND: Neuroprostheses are used to electrically stimulate the brain, modulate neural activity and restore sensory and motor function following injury or disease, such as blindness, paralysis, and other movement and psychiatric disorders. Recordings are often made simultaneously with stimulation, allowing the monitoring of neural signals and closed-loop control of devices. However, stimulation-evoked artifacts may obscure neural activity, particularly when stimulation and recording sites are nearby. Several methods have been developed to remove stimulation artifacts, but it remains challenging to validate and compare these methods because the 'ground-truth' of the neuronal signals may be contaminated by artifacts. NEW METHOD: Here, we delivered stimulation to the visual cortex via a high-channel-count prosthesis while recording neuronal activity and stimulation artifacts. We quantified the waveforms and temporal properties of stimulation artifacts from the cortical visual prosthesis (CVP) and used them to build a dataset, in which we simulated the neuronal activity and the stimulation artifacts. We illustrate how to use the simulated data to evaluate the performance of six software-based artifact removal methods (Template subtraction, Linear interpolation, Polynomial fitting, Exponential fitting, SALPA and ERAASR) in a CVP application scenario. RESULTS: We here focused on stimulation artifacts caused by electrical stimulation through a high-channel-count cortical prosthesis device. We find that the Polynomial fitting and Exponential fitting methods outperform the other methods in recovering spikes and multi-unit activity. Linear interpolation and Template subtraction recovered the local-field potentials. CONCLUSION: Polynomial fitting and Exponential fitting provided a good trade-off between the quality of the recovery of spikes and multi-unit activity (MUA) and the computational complexity for a cortical prosthesis.


Assuntos
Artefatos , Estimulação Elétrica , Córtex Visual , Próteses Visuais , Córtex Visual/fisiologia , Estimulação Elétrica/métodos , Estimulação Elétrica/instrumentação , Animais , Macaca mulatta , Processamento de Sinais Assistido por Computador , Neurônios/fisiologia , Masculino
6.
Sci Robot ; 9(90): eadi8995, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38776378

RESUMO

Closed-loop neuroprostheses show promise in restoring motion in individuals with neurological conditions. However, conventional activation strategies based on functional electrical stimulation (FES) fail to accurately modulate muscle force and exhibit rapid fatigue because of their unphysiological recruitment mechanism. Here, we present a closed-loop control framework that leverages physiological force modulation under functional optogenetic stimulation (FOS) to enable high-fidelity muscle control for extended periods of time (>60 minutes) in vivo. We first uncovered the force modulation characteristic of FOS, showing more physiological recruitment and significantly higher modulation ranges (>320%) compared with FES. Second, we developed a neuromuscular model that accurately describes the highly nonlinear dynamics of optogenetically stimulated muscle. Third, on the basis of the optogenetic model, we demonstrated real-time control of muscle force with improved performance and fatigue resistance compared with FES. This work lays the foundation for fatigue-resistant neuroprostheses and optogenetically controlled biohybrid robots with high-fidelity force modulation.


Assuntos
Fadiga Muscular , Músculo Esquelético , Optogenética , Optogenética/métodos , Optogenética/instrumentação , Animais , Fadiga Muscular/fisiologia , Músculo Esquelético/fisiologia , Humanos , Estimulação Elétrica/instrumentação , Contração Muscular/fisiologia , Robótica/instrumentação , Masculino , Desenho de Equipamento , Próteses Neurais , Dinâmica não Linear
7.
Magn Reson Med ; 92(3): 1290-1305, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38624032

RESUMO

PURPOSE: To demonstrate the performance of gradient array coils in minimizing switched-gradient-induced electric fields (E-fields) and improving peripheral nerve stimulation (PNS) thresholds while generating gradient fields with adjustable linearity across customizable regions of linearity (ROLs). METHODS: A body gradient array coil is used to reduce the induced E-fields on the surface of a body model by modulating applied currents. This is achieved by performing an optimization problem with the peak E-field as the objective function and current amplitudes as unknown variables. Coil dimensions and winding patterns are fixed throughout the optimization, whereas other engineering metrics remain adjustable. Various scenarios are explored by manipulating adjustable parameters. RESULTS: The array design consistently yields lower E-fields and higher PNS thresholds across all scenarios compared with a conventional coil. When the gradient array coil generates target gradient fields within a 44-cm-diameter spherical ROL, the maximum E-field is reduced by 10%, 18%, and 61% for the X, Y, and Z gradients, respectively. Transitioning to a smaller ROL (24 cm) and relaxing the gradient linearity error results in further E-field reductions. In oblique gradients, the array coil demonstrates the most substantial reduction of 40% in the Z-Y direction. Among the investigated scenarios, the most significant increase of 4.3-fold is observed in the PNS thresholds. CONCLUSION: Our study demonstrated that gradient array coils offer a promising pathway toward achieving high-performance gradient coils regarding gradient strength, slew rate, and PNS thresholds, especially in scenarios in which linear magnetic fields are required within specific target regions.


Assuntos
Desenho de Equipamento , Nervos Periféricos , Nervos Periféricos/fisiologia , Humanos , Campos Eletromagnéticos , Imageamento por Ressonância Magnética/instrumentação , Estimulação Elétrica/instrumentação
8.
J Neurosci Methods ; 406: 110131, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38583588

RESUMO

BACKGROUND: The spinal cord and its interactions with the brain are fundamental for movement control and somatosensation. However, brain and spinal electrophysiology in humans have largely been treated as distinct enterprises, in part due to the relative inaccessibility of the spinal cord. Consequently, there is a dearth of knowledge on human spinal electrophysiology, including the multiple pathologies that affect the spinal cord as well as the brain. NEW METHOD: Here we exploit recent advances in the development of wearable optically pumped magnetometers (OPMs) which can be flexibly arranged to provide coverage of both the spinal cord and the brain in relatively unconstrained environments. This system for magnetospinoencephalography (MSEG) measures both spinal and cortical signals simultaneously by employing custom-made scanning casts. RESULTS: We evidence the utility of such a system by recording spinal and cortical evoked responses to median nerve stimulation at the wrist. MSEG revealed early (10 - 15 ms) and late (>20 ms) responses at the spinal cord, in addition to typical cortical evoked responses (i.e., N20). COMPARISON WITH EXISTING METHODS: Early spinal evoked responses detected were in line with conventional somatosensory evoked potential recordings. CONCLUSION: This MSEG system demonstrates the novel ability for concurrent non-invasive millisecond imaging of brain and spinal cord.


Assuntos
Magnetoencefalografia , Medula Espinal , Humanos , Medula Espinal/fisiologia , Medula Espinal/diagnóstico por imagem , Magnetoencefalografia/instrumentação , Magnetoencefalografia/métodos , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem , Adulto , Masculino , Feminino , Nervo Mediano/fisiologia , Nervo Mediano/diagnóstico por imagem , Potenciais Somatossensoriais Evocados/fisiologia , Magnetometria/instrumentação , Magnetometria/métodos , Adulto Jovem , Estimulação Elétrica/instrumentação
9.
Biomater Adv ; 160: 213830, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38552500

RESUMO

Cancer, namely breast and prostate cancers, is the leading cause of death in many developed countries. Controlled drug delivery systems are key for the development of new cancer treatment strategies, to improve the effectiveness of chemotherapy and tackle off-target effects. In here, we developed a biomaterials-based wireless electrostimulation system with the potential for controlled and on-demand release of anti-cancer drugs. The system is composed of curcumin-loaded poly(3,4-ethylenedioxythiophene) nanoparticles (CUR/PEDOT NPs), encapsulated inside coaxial poly(glycerol sebacate)/poly(caprolactone) (PGS/PCL) electrospun fibers. First, we show that the PGS/PCL nanofibers are biodegradable, which allows the delivery of NPs closer to the tumoral region, and have good mechanical properties, allowing the prolonged storage of the PEDOT NPs before their gradual release. Next, we demonstrate PEDOT/CUR nanoparticles can release CUR on-demand (65 % of release after applying a potential of -1.5 V for 180 s). Finally, a wireless electrostimulation platform using this NP/fiber system was set up to promote in vitro human prostate cancer cell death. We found a decrease of 67 % decrease in cancer cell viability. Overall, our results show the developed NP/fiber system has the potential to effectively deliver CUR in a highly controlled way to breast and prostate cancer in vitro models. We also show the potential of using wireless electrostimulation of drug-loaded NPs for cancer treatment, while using safe voltages for the human body. We believe our work is a stepping stone for the design and development of biomaterial-based future smarter and more effective delivery systems for anti-cancer therapy.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Glicerol/análogos & derivados , Nanopartículas , Poliésteres , Polímeros , Tecnologia sem Fio , Humanos , Compostos Bicíclicos Heterocíclicos com Pontes/química , Nanopartículas/química , Polímeros/química , Poliésteres/química , Curcumina/administração & dosagem , Curcumina/química , Glicerol/química , Masculino , Neoplasias da Próstata/terapia , Antineoplásicos/administração & dosagem , Decanoatos/química , Nanofibras/química , Sistemas de Liberação de Medicamentos/instrumentação , Sistemas de Liberação de Medicamentos/métodos , Linhagem Celular Tumoral , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos
10.
Biomaterials ; 304: 122421, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38065037

RESUMO

Self-powered neurostimulation via biomaterials and bioelectronics innovation has emerged as a compelling approach to explore, repair, and modulate neural systems. This review examines the application of self-powered bioelectronics for electrical stimulation of both the central and peripheral nervous systems, as well as isolated neurons. Contemporary research has adeptly harnessed biomechanical and biochemical energy from the human body, through various mechanisms such as triboelectricity, piezoelectricity, magnetoelasticity, and biofuel cells, to power these advanced bioelectronics. Notably, these self-powered bioelectronics hold substantial potential for delivering neural stimulations that are customized for the treatment of neurological diseases, facilitation of neural regeneration, and the development of neuroprosthetics. Looking ahead, we expect that the ongoing advancements in biomaterials and bioelectronics will drive the field of self-powered neurostimulation toward the realization of more advanced, closed-loop therapeutic solutions, paving the way for personalized and adaptable neurostimulators in the coming decades.


Assuntos
Materiais Biocompatíveis , Estimulação Elétrica , Eletrônica , Humanos , Estimulação Elétrica/instrumentação
11.
Artigo em Inglês | MEDLINE | ID: mdl-38083178

RESUMO

Function electrical stimulation (FES) is recommended as one of the effective methods for rehabilitation of motor function after stroke. There are two forms to deliver electrical stimulation to induce muscle contraction: Bipolar electrode configuration with two electrodes of the same size, and monopolar electrode configuration with a bigger electrode as an indifferent electrode and a smaller one as an active electrode. The purpose of this study is to compare the two kinds of configuration on biceps brachii in terms of induced muscle contraction force and muscle fatigue. In the experiment, electrical stimulation was applied on biceps brachii muscles of the right arm. Isometric contraction was induced by fixing the elbow joint during the stimulation. The experimental results showed that the induced contraction force was bigger using monopolar electrode configuration with the indifferent electrode on the antagonist muscle, and there was no significant difference in muscle fatigue between the configurations. Monopolar electrode configuration with the indifferent electrode on the antagonist muscle was suggested as the most effective method for FES on biceps brachii.Clinical Relevance- This study establishes an effective electrode configuration for FES on biceps brachii.


Assuntos
Braço , Estimulação Elétrica , Eletrodos , Músculo Esquelético , Reabilitação do Acidente Vascular Cerebral , Braço/fisiopatologia , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Eletromiografia , Músculo Esquelético/fisiopatologia , Recuperação de Função Fisiológica , Reabilitação do Acidente Vascular Cerebral/instrumentação , Reabilitação do Acidente Vascular Cerebral/métodos
12.
IEEE Trans Biomed Eng ; 70(2): 756-765, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36037456

RESUMO

OBJECTIVE: Motor imagery (MI) based brain- computer interface (BCI) has been widely studied as an effective way to enhance motor learning and promote motor recovery. However, the accuracy of MI-BCI heavily depends on whether subjects can perform MI tasks correctly, which largely limits the general application of MI-BCI. To overcome this limitation, a training strategy based on the combination of MI and sensory threshold somatosensory electrical stimulation (MI+st-SES) is proposed in this study. METHODS: Thirty healthy subjects were recruited and randomly divided into SES group and control group. Both groups performed left-hand and right-hand MI tasks in three consecutive blocks. The main difference between two groups lies in the second block, where subjects in SES group received the st-SES during MI tasks whereas the control group performed MI tasks only. RESULTS: The results showed that the SES group had a significant improvement in event-related desynchronization (ERD) of alpha rhythm after the training session of MI+st-SES (left-hand: F(2,27) = 9.98, p<0.01; right-hand: F(2, 27) = 10.43, p<0.01). The classification accuracy between left- and right-hand MI in the SES group was also significantly improved following MI+st-SES training (F(2,27) = 6.46, p<0.01). In contrary, there was no significant difference between the first and third blocks in the control group (F(2,27) = 0.18, p = 0.84). The functional connectivity based on weighted pairwise phase consistency (wPPC) over the sensorimotor area also showed an increase after the MI+st-SES training. CONCLUSION AND SIGNIFICANCE: Our findings indicate that training based on MI+st-SES is a promising way to foster MI performance and assist subjects in achieving efficient BCI control.


Assuntos
Estimulação Elétrica , Córtex Somatossensorial , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Humanos , Adulto Jovem , Adulto , Visão Ocular , Limiar Sensorial
13.
Nanotechnology ; 33(18)2022 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013010

RESUMO

In the treatment of neurodegenerative, sensory and cardiovascular diseases, electrical probes and arrays have shown quite a promising success rate. However, despite the outstanding clinical outcomes, their operation is significantly hindered by non-selective control of electric fields. A promising alternative is micromagnetic stimulation (µMS) due to the high permeability of magnetic field through biological tissues. The induced electric field from the time-varying magnetic field generated by magnetic neurostimulators is used to remotely stimulate neighboring neurons. Due to the spatial asymmetry of the induced electric field, high spatial selectivity of neurostimulation has been realized. Herein, some popular choices of magnetic neurostimulators such as microcoils (µcoils) and spintronic nanodevices are reviewed. The neurostimulator features such as power consumption and resolution (aiming at cellular level) are discussed. In addition, the chronic stability and biocompatibility of these implantable neurostimulator are commented in favor of further translation to clinical settings. Furthermore, magnetic nanoparticles (MNPs), as another invaluable neurostimulation material, has emerged in recent years. Thus, in this review we have also included MNPs as a remote neurostimulation solution that overcomes physical limitations of invasive implants. Overall, this review provides peers with the recent development of ultra-low power, cellular-level, spatially selective magnetic neurostimulators of dimensions within micro- to nano-range for treating chronic neurological disorders. At the end of this review, some potential applications of next generation neuro-devices have also been discussed.


Assuntos
Estimulação Elétrica , Campos Magnéticos , Estimulação Elétrica/instrumentação , Humanos , Neuroestimuladores Implantáveis , Nanopartículas de Magnetita/uso terapêutico , Doenças do Sistema Nervoso/terapia
14.
Adv Sci (Weinh) ; 9(1): e2103005, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34708571

RESUMO

The neuronal engagement of the peripheral nerve system plays a crucial role in regulating fracture healing, but how to modulate the neuronal activity to enhance fracture healing remains unexploited. Here it is shown that electrical stimulation (ES) directly promotes the biosynthesis and release of calcitonin gene-related peptide (CGRP) by activating Ca2+ /CaMKII/CREB signaling pathway and action potential, respectively. To accelerate rat femoral osteoporotic fracture healing which presents with decline of CGRP, soft electrodes are engineered and they are implanted at L3 and L4 dorsal root ganglions (DRGs). ES delivered at DRGs for the first two weeks after fracture increases CGRP expression in both DRGs and fracture callus. It is also identified that CGRP is indispensable for type-H vessel formation, a biological event coupling angiogenesis and osteogenesis, contributing to ES-enhanced osteoporotic fracture healing. This proof-of-concept study shows for the first time that ES at lumbar DRGs can effectively promote femoral fracture healing, offering an innovative strategy using bioelectronic device to enhance bone regeneration.


Assuntos
Regeneração Óssea/fisiologia , Peptídeo Relacionado com Gene de Calcitonina/metabolismo , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Consolidação da Fratura/fisiologia , Gânglios Espinais/metabolismo , Fraturas por Osteoporose/terapia , Animais , Modelos Animais de Doenças , Fraturas por Osteoporose/metabolismo , Ratos
15.
Medicine (Baltimore) ; 100(37): e27291, 2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34664890

RESUMO

BACKGROUND: The aim of this meta-analysis was to compare the short-term outcomes surrounding the efficacy and complication rate between different modalities of pyloromyotomy and gastric electrical stimulation (GES) in the treatment of gastroparesis. METHODS: Comprehensive, computerized research was performed on PubMed, Embase, and the Cochrane Central Register of Controlled Trials. We additionally reviewed relevant articles, without any language limitations, published prior to April 15, 2020. Meta-analysis was conducted using RevMan 5.3 software. RESULTS: Three studies totaling 196 participants who had received 4 interventions, including single per-oral pyloromyotomy (POP), double POP, laparoscopic pyloromyotomy, and GES, were eligible for analysis. Compared to single POP, double POP achieved a better clinical response with a pooled relative risk (RR) of 1.27 (95% confidence interval [CI], 1.01-1.60, P = .04), while laparoscopic pyloromyotomy and GES showed no difference with a pooled RR of 0.89 (95% CI, 0.74-1.08, P = .23) and 0.87 (95% CI, 0.73-1.04, P = .13), respectively. As for the recurrence and complication rates, only GES showed a borderline significance of recurrence in comparison to single POP (RR 2.17, 95% CI, 1.00-4.71, P = .05), while there were no differences in the remainder of the comparisons. CONCLUSIONS: We conducted a detailed comparison of 3 modalities of pyloromyotomy and GES in the treatment of gastroparesis, with the results suggesting that double POP demonstrated better clinical success with similar recurrence and complication rates. In addition, GES may result in more recurrence amongst these interventions.


Assuntos
Currículo/normas , Estimulação Elétrica/métodos , Gastroparesia/terapia , Piloromiotomia/normas , Currículo/tendências , Estimulação Elétrica/instrumentação , Gastroparesia/fisiopatologia , Humanos , Piloromiotomia/métodos , Piloromiotomia/tendências , Resultado do Tratamento
16.
Adv Mater ; 33(48): e2104175, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34608668

RESUMO

The long-segment peripheral nerve injury (PNI) represents a global medical challenge, leading to incomplete nerve tissue recovery and unsatisfactory functional reconstruction. However, the current electrical stimulation (ES) apparatuses fail perfect nerve repair due to their inability of the variable synchronous self-regulated function with physiological states. It is urgent to develop an implantable ES platform with physiologically adaptive function to provide instantaneous and nerve-preferred ES. Here, a physiologically self-regulated electrical signal is generated by integrating a novel tribo/piezoelectric hybrid nanogenerator with a nanoporous nerve guide conduit to construct a fully implantable neural electrical stimulation (FI-NES) system. The optimal neural ES parameters completely originate from the body itself and are highly self-responsive to different physiological states. The morphological evaluation, representative protein expression level, and functional reconstruction of the regenerated nerves are conducted to assess the PNI recovery process. Evidence shows that the recovery effect of 15 mm length nerve defects under the guidance of the FI-NES system is significantly close to the autograft. The designed FI-NES system provides an effective method for long-term accelerating the recovery of PNI in vivo and is also appropriate for other tissue injury or neurodegenerative diseases.


Assuntos
Estimulação Elétrica/métodos , Regeneração Nervosa/fisiologia , Traumatismos dos Nervos Periféricos/terapia , Animais , Estimulação Elétrica/instrumentação , Polímeros de Fluorcarboneto/química , Regeneração Tecidual Guiada , Nanoporos , Nanotecnologia , Neovascularização Fisiológica/genética , Polivinil/química , Próteses e Implantes , Ratos , Ratos Sprague-Dawley
17.
J Nanobiotechnology ; 19(1): 280, 2021 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-34544434

RESUMO

BACKGROUND: Electrostimulation (ES) therapy for wound healing is limited in clinical use due to barriers such as cumbersome equipment and intermittent delivery of therapy. METHODS: We adapted a human skin xenograft model that can be used to directly examine the nanogenerator-driven ES (NG-ES) effects on human skin in vivo-an essential translational step toward clinical application of the NG-ES technique for wound healing. RESULTS: We show that NG-ES leads to rapid wound closure with complete restoration of normal skin architecture within 7 days compared to more than 30 days in the literature. NG-ES accelerates the inflammatory phase of wound healing with more rapid resolution of neutrophils and macrophages and enhances wound bed perfusion with more robust neovascularization. CONCLUSION: Our results support the translational evaluation and optimization of the NG-ES technology to deliver convenient, efficient wound healing therapy for use in human wounds.


Assuntos
Estimulação Elétrica/métodos , Pele/patologia , Cicatrização , Animais , Bandagens , Estimulação Elétrica/instrumentação , Eletrodos , Humanos , Queratina-15/metabolismo , Camundongos , Camundongos Nus , Nanotecnologia , Pele/metabolismo , Transplante de Pele
18.
Laryngoscope ; 131(10): E2718-E2726, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34350983

RESUMO

OBJECTIVES/HYPOTHESIS: During intraoperative neuromonitoring in thyroid surgery, two different kinds of stimulator probes, monopolar and bipolar, are commonly used to stimulate the laryngeal nerves. We explore the unique characteristics of both of these probes as they relate to intraoperative laryngeal nerve mapping. METHODS: Twenty-one patients undergoing neuromonitored thyroidectomy by a single surgeon were enrolled. Electromyography (EMG) amplitude and latency measurements were prospectively recorded concurrently from 1 mA stimulation of vagus nerve (VN) and inferior/superior recurrent laryngeal nerve before (with and without fascia) and after thyroid resection using bipolar and monopolar stimulator probes. RESULTS: Significantly higher amplitudes were obtained with monopolar stimulator probes as compared to bipolar probes, in several stimulation scenarios such as at right VN pre-resection (carotid sheath intact), right VN pre-resection (carotid sheath dissected), right VN post-resection and left VN (carotid sheath dissected). No significant differences were found between amplitudes and latency values in all other stimulation scenarios. CONCLUSIONS: According to this study, both probes are reliable and safe for neural mapping. The kind of probe used during neural monitoring is based on surgical situations and surgeon preference. LEVEL OF EVIDENCE: 3 (According to Oxford Centre for Evidence-Based Medicine 2011 Levels of Evidence) Laryngoscope, 131:E2718-E2726, 2021.


Assuntos
Estimulação Elétrica/instrumentação , Monitorização Intraoperatória/instrumentação , Nervo Laríngeo Recorrente/fisiologia , Tireoidectomia , Nervo Vago/fisiologia , Adulto , Idoso , Eletromiografia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
19.
Clin Neurophysiol ; 132(10): 2351-2356, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34454261

RESUMO

OBJECTIVE: The present study investigated the effects of the stimulus polarity and location of motor evoked potential (MEP) to establish a stimulation protocol. METHODS: Nineteen patients who intraoperatively underwent MEP in bipolar direct cortical stimulation were enrolled in the present study. Somatosensory evoked potentials (SEP) of the contralateral median nerve stimulation were recorded to determine stimulation sites. MEP was performed under two settings in all patients: 1. Anodal bipolar stimulation: an anode on the precentral gyrus and a cathode on the postcentral gyrus, 2. Cathodal bipolar stimulation: a cathode on the precentral gyrus and an anode on the postcentral gyrus. MEP amplitudes and the coefficient of variation (CV) at a stimulation intensity of 25 mA and the thresholds of induced MEP were compared between the two settings. RESULTS: An electrical stimulation at 25 mA induced a significantly higher amplitude in cathodal bipolar stimulation than in anodal bipolar stimulation. Cathodal bipolar stimulation also showed significantly lower thresholds than anodal stimulation. CV did not significantly differ between the two groups. CONCLUSIONS: These results indicate that cathodal bipolar stimulation is superior to anodal bipolar stimulation for intraoperative MEP monitoring. SIGNIFICANCE: MEP in cathodal bipolar cortical stimulation may be used in a safe and useful evaluation method of motor fiber damage that combines sensitivity and specificity.


Assuntos
Eletrodos Implantados , Potencial Evocado Motor/fisiologia , Potenciais Somatossensoriais Evocados/fisiologia , Monitorização Neurofisiológica Intraoperatória/métodos , Córtex Motor/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/instrumentação , Masculino , Pessoa de Meia-Idade
20.
IEEE Pulse ; 12(3): 14-17, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34156928

RESUMO

An estimated ten million people in the United States have a condition known as essential tremor (ET). Yet although it's been recognized for over a century-it was originally known as senile tremor-there is relatively little awareness of it as a distinct medical condition. Sometimes mistaken for Parkinson's disease, ET can lead to shaking of the arms and hands, and sometimes the head or torso. When severe, it can interfere with eating or drinking, writing, dressing, and even make some tasks impossible. Now, new approaches for treating the condition are emerging, potentially offering options to many patients whose life activities have been curtailed by ET.


Assuntos
Estimulação Elétrica/instrumentação , Tremor , Dispositivos Eletrônicos Vestíveis , Eletrônica Médica/instrumentação , Humanos , Tremor/diagnóstico , Tremor/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...