Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.750
Filtrar
1.
Sci Rep ; 14(1): 13064, 2024 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844596

RESUMO

This study aimed to investigate carbamate pesticide residues in different varieties of date palm fruits in the UAE, utilizing UHPLC-MS/MS. For sample preparation and clean-up, the efficiency and performance of different QuEChERS dispersive solid-phase extraction kits were compared. Precision and recovery were assessed at 10 µg kg-1 for the three kits, revealing that Kit 2 demonstrated the best performance. The selected QuEChERS method was validated to detect 14 carbamate residues in 55 date samples. The method exhibited strong linearity with R2 > 0.999 and low LOD (0.01-0.005 µg kg-1) and LOQ (0.003-0.04 µg kg-1). Excellent accuracy (recovery: 88-106%) and precision (RSD: 1-11%) were observed, with negligible matrix effect (- 4.98-13.26%). All samples contained at least one carbamate residue. While most detected residues were below their MRLs, carbosulfan was found in 21 samples, propoxur in 2 samples, and carbofuran in 1 sample above their MRLs. The hazard index (HI) was calculated for carbosulfan, phenmedipham, carbaryl, propoxur, carbofuran, and methomyl to assess potential health risks for date consumers. All HI values were below the safety limit of 1.0, indicating that the consumption of dates does not pose a non-carcinogenic health risk for adults and children.


Assuntos
Carbamatos , Frutas , Resíduos de Praguicidas , Phoeniceae , Espectrometria de Massas em Tandem , Phoeniceae/química , Resíduos de Praguicidas/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Carbamatos/análise , Frutas/química , Humanos , Medição de Risco , Extração em Fase Sólida/métodos , Contaminação de Alimentos/análise
2.
Anal Chim Acta ; 1312: 342780, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38834272

RESUMO

BACKGROUND: The convenient preparation and application of functionalized organic-inorganic hybrid monolithic materials have obtained substantial interest in the pretreatment of complex samples by solid-phase extraction (SPE). Compared to the in-tube solid-phase microextraction in fused-silica capillaries, micro SPE in plastic pipette tips have fascinating merits for the easily operated enrichment of trace target analytes from biological samples. However, the poor compatibility of organic-inorganic hybrid monoliths with plastics leads to the rare appearance of commercial hybrid monolithic pipette tips (HMPTs). Therefore, how to synthesize the organic-inorganic hybrid monolithic materials with better extraction performance in plastic pipette tips becomes a challenge. RESULTS: We develop a facile and cheap strategy to immobilize organic-inorganic hybrid monoliths in pipette tips. Melamine sponge was employed as the supporting skeleton to in situ assemble amine- and thiol-bifunctionalized hybrid monolithic material via "one pot" in a pipette tip, and gold nanoparticles (GNPs) and thiol-modified aptamer against human α-thrombin were sequentially attached to the hybrid monolith within the HMPTs. The average coverage density of the aptamer with GNPs as an intermediary reached as high as 818.5 pmol µL-1. The enriched thrombin concentration was determined by a sensitive enzymatic chromogenic assay with the limit of detection of 2 nM. The extraction recovery of thrombin at 10 nM in human serum was 86.1 % with a relative standard deviation of 6.1 %. This proposed protocol has been applied to the enrichment and determination of thrombin in real serum sample with strong anti-interference ability, low limit of detection and high recovery. SIGNIFICANCE: The amine- and thiol-bifunctionalized HMPTs prepared with sponge as the skeleton frame provided a novel substrate material to decorate aptamers for efficient enrichment of proteins. This enlightens us that we can take advantage of the tunability of sponge assisted HMPTs to produce and tailor a variety of micro SPE pipette tips for broader applications on the analysis of trace targets in complex biological, clinic and environmental samples.


Assuntos
Aptâmeros de Nucleotídeos , Trombina , Triazinas , Triazinas/química , Triazinas/isolamento & purificação , Aptâmeros de Nucleotídeos/química , Humanos , Trombina/análise , Trombina/isolamento & purificação , Ouro/química , Nanopartículas Metálicas/química , Extração em Fase Sólida/métodos
3.
J Chromatogr A ; 1729: 465030, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38838449

RESUMO

Exposure to tobacco smoke is highly correlated to the incidence of different types of cancer due to various carcinogenic compounds present in such smoke. Aromatic amines, such as 1-naphthylamine (1-NA) and 2-naphthylamine (2-NA), are produced in tobacco burning and are linked to bladder cancer. Miniaturized solid phase extraction techniques, such as microporous membrane solid phase extraction (MMSPE), have shown potential for the extraction of aromatic compounds. In this study, a bioanalytical method for the determination of 1-NA and 2-NA in human urine was developed using polypropylene microporous membranes as a sorptive phase for MMSPE. Urine samples were hydrolyzed with HCl for 1 h at 80 °C, after which pH was adjusted to 10. Ultrasound-assisted MMSPE procedure was optimized by factorial design as follows. To each sample, 750 µL of methanol was added, and ultrasound-assisted MMSPE was conducted for 1 h with four devices containing seven 2 mm polypropylene membrane segments. After extraction, the segments were transferred to 400 µL of hexane, and desorption was conducted for 30 min. Extracts were submitted to a simple and fast microwave-assisted derivatization procedure, by the addition of 10 µL of PFPA and heating at 480 W for 3 min, followed by clean-up with phosphate buffer pH 8.0 and GC-MS/MS analysis. Adequate linearity was obtained for both analytes in a range from 25 to 500 µg L-1, while the multiple reaction monitoring approach provided satisfactory selectivity and specificity. Intra-day (n = 6) and inter-day (n = 5) precision and accuracy were satisfactory, below 15 % and between 85 and 115 %, respectively. Recovery rates found were 91.9 and 58.4 % for 1-NA and 2-NA, respectively, with adequate precision. 1-NA was found in first-hand smokers' urine samples in a concentration range from 20.98 to 89.09 µg in 24 h, while it could be detected in second-hand smoker's urine samples, and 2-NA detected in all first and second-hand smokers' urine samples. The proposed method expands the applicability of low cost MMSPE devices to aromatic amines and biological fluids.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Polipropilenos , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Humanos , Polipropilenos/química , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Extração em Fase Sólida/métodos , Carcinógenos/análise , Carcinógenos/isolamento & purificação , Reprodutibilidade dos Testes , 1-Naftilamina/análogos & derivados , 1-Naftilamina/química , Membranas Artificiais , 2-Naftilamina/análogos & derivados , 2-Naftilamina/química , Porosidade , Fumantes
4.
J Chromatogr A ; 1729: 465040, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38838450

RESUMO

In this work, porous polyimide microfibers (PI-µF) were prepared by high-pressure wet spinning method, and successfully applied as adsorbents for solid phase extraction (SPE) of fluoroquinolones (FQs) in water and food samples. The PI-µFs of ∼10, 25, 50, 100 µm in diameter could be controlled by the inner diameter of quartz capillary nozzles. The flow resistance of SPE cartridges packed with 10 µm PI microfiber (10-PI-µF) and 25-PI-µF was comparable to or even lower than that of commercial SPE cartridges, while the flow resistance of 50-PI-µF and 100-PI-µF SPE cartridges was increased obviously due to tiny broken pieces. The 10-PI-µF and 25-PI-µF have a specific surface area of 102 m2 g-1 and 76 m2 g-1, mesopores of 22-32 nm, and large breakthrough volume of 110 mL/5 mg and 85 mL/5 mg for FQs, while the 50-PI-µF and 100-PI-µF had much lower specific surface area and hardly had retention for FQs. FQs from tap water, egg and milk samples were then extracted by PI-µF SPE, and analyzed by high performance liquid chromatography-fluorescence detector (HPLC-FLD). SPE parameters as type of elution solvent, elution solvent volume, pH value of sample solution, flow rate of sample solution, and breakthrough volume were first optimized in detail. Under the optimal conditions, the PI-µF SPE/HPLC-FLD method showed high recoveries (96.8%-107%), wide linearity (0.05-50 µg L-1, or 0.01-10 µg L-1), high determination coefficients (R2 ≥0.9992), and low limits of detection (LODs, 0.005-0.014 µg L-1). For the real tap water, egg and milk samples, the recoveries and RSDs were 81-119% and 0.8-9.8%, respectively. The results show that porous microfiber up to 25 µm in diameter is a promising solid-phase extraction adsorbent with the lowest flow resistance that can be used for trace organic pollutants in water and food samples.


Assuntos
Fluoroquinolonas , Limite de Detecção , Leite , Extração em Fase Sólida , Poluentes Químicos da Água , Extração em Fase Sólida/métodos , Fluoroquinolonas/análise , Fluoroquinolonas/isolamento & purificação , Fluoroquinolonas/química , Porosidade , Leite/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Poluentes Químicos da Água/química , Cromatografia Líquida de Alta Pressão/métodos , Animais , Ovos/análise , Adsorção , Pressão , Contaminação de Alimentos/análise , Resinas Sintéticas/química , Análise de Alimentos/métodos , Reprodutibilidade dos Testes
5.
Artigo em Inglês | MEDLINE | ID: mdl-38851151

RESUMO

In this study, a magnetic three-dimensional nano-composite based on Rubber-Fe3O4@Ni-Co Layered double hydroxide derived from ZIF-67 template was synthesized by a hydrothermal method. The proposed nano-composite was used as a sorbent for the enrichment of trace amounts of anti-cancer drugs (dasatinib and erlotinib hydrochloride) from plasma samples followed by determination using high-performance liquid chromatographic analysis (HPLC-UV). The synthesized nano-sorbent was characterized by X-ray diffraction, field emission scanning electron microscopy, Fourier transform infrared spectroscopy, vibrating-sample magnetometer, Brunauer-Emmett-Teller surface analysis, Barrett-Joyner-Halenda pore size analysis and energy dispersive X-ray spectroscopy. Under optimal experimental conditions, factors affecting on extraction efficiency such as pH, ionic strength, extraction temperature and time, desorption solvent and time, the limit of detection (LODs) and the limit of quantification (LOQs) were obtained as 0.6, 2 µg/L for both of dasatinib and erlotinib, respectively. Also, linear range of the method were 2-500 and 2-1000 µg/L for dasatinib and erlotinib, respectively. Relative standard deviations (RSD%) for the repeatability of extraction on sorbent to sorbent were obtained as 3.59, 1.97 %, and one sorbent reusability were investigated and relative standard deviation values were obtained 5.35, 3.30 % for dasatinib and erlotinib, respectively.


Assuntos
Antineoplásicos , Cloridrato de Erlotinib , Limite de Detecção , Borracha , Borracha/química , Antineoplásicos/sangue , Antineoplásicos/química , Cromatografia Líquida de Alta Pressão/métodos , Reprodutibilidade dos Testes , Humanos , Cloridrato de Erlotinib/sangue , Cloridrato de Erlotinib/química , Modelos Lineares , Dasatinibe/sangue , Dasatinibe/química , Hidróxidos/química , Imidazóis/química , Imidazóis/sangue , Adsorção , Extração em Fase Sólida/métodos , Cobalto/química , Cobalto/sangue , Nanoestruturas/química , Zeolitas
6.
J Chromatogr A ; 1729: 465012, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38852264

RESUMO

Acrylamide and N, N-methylene bis acrylamide are most commonly used monomer and crosslinker compounds employed in synthesis of super absorbent hydrogels. When applied as soil conditioners, there are apprehensions that these hydrogels degrade over time and thus may release the toxic monomers in the soil. A method was thus developed using Liquid Chromatography tandem mass spectrometry (LC-MS/MS) for the trace level quantification of acrylamide (AD), acrylic acid (AA) and N,N-methylene-bis-acrylamide (MBA) in sandy loam soil amended by two test hydrogels the Pusa Hydrogel and SPG 1118 hydrogel prepared using AD and MBA. The MRM (multiple reaction monitoring) transitions were optimized for both the compounds. Soil samples were extracted using dispersive solid-phase extraction (dSPE) with a modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) technique, employing acetonitrile. All analytes were quantified at trace levels within a five-minute run using UHPLC equipped with a C-18 column. Single laboratory validation of the developed method in soil matrix was conducted based on specificity, linearity, sensitivity, accuracy, precision, matrix effect and measurement of uncertainty. LC-MS/MS exhibited a linear response in the concentration range of 0.001 to 1 µg mL-1, with correlation coefficient >+0.99. Acceptable recovery (within 70-120 %) with repeatability (%RSD ≤20 %) was obtained at 0.01 to 1 µg g-1 fortification levels. LOQ (Limit of quantification) of the method for AD, AA and MBA in soil matrix were 0.05, 1 and 0.01 µg g-1, respectively. Both intra-laboratory repeatability and intermediate precision at LOQ suggested well acceptable precise (HorRat≈ 0.3) method for quantification. Matrix enhancement effect was observed in the order: AA>AD>MBA. The Expanded Uncertainty (EU) in soil matrix at LOQ was 21.64 %, 28 % and 19 % for AD, AA and MBA respectively. Groundnut and wheat grown with application of the hydrogels showed no detectable residues of monomers in soil samples (total n = 60) near the root zone at the time of crop harvesting.


Assuntos
Acrilamida , Acrilamidas , Acrilatos , Poluentes do Solo , Solo , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Acrilatos/análise , Acrilatos/química , Acrilamida/análise , Solo/química , Acrilamidas/química , Acrilamidas/análise , Poluentes do Solo/análise , Extração em Fase Sólida/métodos , Reprodutibilidade dos Testes , Limite de Detecção , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Hidrogéis/química , Espectrometria de Massa com Cromatografia Líquida
7.
J Sep Sci ; 47(11): e2300915, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38847294

RESUMO

In this work, core-shell material with a special structure was designed and applied in solid-phase extraction (SPE) for non-steroidal anti-inflammatory drugs (NSAIDs) combined with high-performance liquid chromatography. Based on the advantages of core-shell ZIF-8@ZIF-67 (Zeolite imidazole ester framework materials [ZIFs]), effective derivatization treatment was carried out to partially vulcanize the original ZIFs, resulting in a special and new double-core-shell structural material CoS/ZIF-67/ZnS/ZIF-8 (ZIFs@ZnS@CoS) with porous surface and center hollow. The multiple forces caused by the rich chemical structure, the large specific surface area caused by the special pore structure, and the effective protection of the ZIFs core by sulfide shell make the designed material have higher extraction efficiency and longer service life, compared with ZIF-8@ZIF-67 and ZIF-8. At the same time, the established analytical method for non-steroidal drugs had a high recovery rate (98.93%-102.10%), low detection limit (0.11-0.27 µg/L), and wide linear range (1-200 µg/L) within a good correlation coefficient R2 (0.9978-0.9993). Satisfactory results were also obtained from the extraction of NSAIDs from the Yellow River water samples. These results indicate that the designed double-core-shell structure material can effectively exert its structural advantages and become a promising extraction material.


Assuntos
Anti-Inflamatórios não Esteroides , Extração em Fase Sólida , Anti-Inflamatórios não Esteroides/química , Anti-Inflamatórios não Esteroides/isolamento & purificação , Anti-Inflamatórios não Esteroides/análise , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão , Propriedades de Superfície , Poluentes Químicos da Água/química , Poluentes Químicos da Água/isolamento & purificação , Poluentes Químicos da Água/análise , Tamanho da Partícula , Estruturas Metalorgânicas/química , Estrutura Molecular , Porosidade , Zeolitas/química , Adsorção , Imidazóis/química
8.
Carbohydr Polym ; 339: 122257, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38823923

RESUMO

Traditional solid phase extraction (SPE) suffers from a lack of specific adsorption. To overcome this problem, a combination of adsorption method and molecular imprinting technology by polydopamine modification was proposed to realize specific recognition of target compounds in SPE, which is of great significance to improve the separation efficiency of SPE. Cellulose hydrogel beads were prepared by dual cross-linking curing method and modified with polydopamine to make them hydrophilic and biocompatible. Subsequently, cellulose hydrogel-based molecularly imprinted beads (MIBs) were synthesized by surface molecular imprinting technology and used as novel column fillers in SPE to achieve efficient adsorption (34.16 mg·g-1) with specific selectivity towards camptothecin (CPT) in 120 min. The simulation and NMR analysis revealed that recognition mechanism of MIBs involved hydrogen bond interactions and Van der Waals effect. The MIBs were successful used in separating CPT from Camptotheca acuminata fruits, exhibiting impressive adsorption capacity (1.19 mg·g-1) and efficient recovery of CPT (81.54 %). Thus, an environmentally friendly column filler for SPE was developed, offering a promising avenue for utilizing cellulose-based materials in the selective separation of natural products.


Assuntos
Camptotecina , Celulose , Hidrogéis , Impressão Molecular , Extração em Fase Sólida , Camptotecina/química , Camptotecina/isolamento & purificação , Celulose/química , Adsorção , Impressão Molecular/métodos , Hidrogéis/química , Extração em Fase Sólida/métodos , Camptotheca/química , Polímeros/química , Interações Hidrofóbicas e Hidrofílicas , Indóis/química , Frutas/química
9.
Anal Methods ; 16(23): 3784-3797, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38828558

RESUMO

Newly designed micro-solid phase extraction cartridges are now available, reflecting the increasing shift towards laboratory automation, especially in the clean-up step for the analysis of pesticide residues in food and feed. In the present study, the introduction of different sorbents on the newly designed PAL µSPE CTC cartridges was investigated for the removal of matrix interferents and the recovery of pesticides. Eight cartridges containing different sorbent combinations and different amounts were used including EMR-lipid (not activated), Z-sep, chitin, C18, PSA, and GCB. The evaluation of co-extractive removal for each cartridge showed that the optimal choice for removing fatty acids was the cartridges containing PSA and Z-sep as clean-up sorbents. However, the presence of C18 and EMR-lipid was still required for the removal of sterols and tocopherols. Two grams of sample, fish feed (FF) and rapeseed cake (RSC) were extracted using QuEChERS citrate buffer, followed by a freeze-out step. The recoveries and repeatability of QuEChERS using µ-SPE clean-up were evaluated for 216 pesticide residues (112 compounds analyzed by GC-MS/MS and 143 compounds by LC-MS/MS, from which 39 compounds were analyzed using both techniques). The best results, with recovery between 70 and 120% and RSD <20%, were achieved when FF samples were cleaned-up with 15 mg EMR-lipid and 20 mg MgSO4. This was achieved for 94% of GC-amenable compounds and 86% of LC-amenable compounds. In the case of RSC, the best results were seen when samples were cleaned-up with the cartridge containing only 20 mg Z-sep and 20 mg MgSO4. This was achieved for 88% of GC-amenable compounds and 90% of LC-amenable compounds. Although these cartridges yielded optimal results in terms of recovery, their use could require more instrument maintenance, especially for GC-MS/MS, due to the lower removal of co-extractives.


Assuntos
Ração Animal , Resíduos de Praguicidas , Microextração em Fase Sólida , Resíduos de Praguicidas/análise , Microextração em Fase Sólida/métodos , Ração Animal/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Contaminação de Alimentos/análise , Extração em Fase Sólida/métodos , Animais
10.
Se Pu ; 42(6): 508-523, 2024 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-38845512

RESUMO

Given continuous improvements in industrial production and living standards, the analysis and detection of complex biological sample systems has become increasingly important. Common complex biological samples include blood, serum, saliva, and urine. At present, the main methods used to separate and recognize target analytes in complex biological systems are electrophoresis, spectroscopy, and chromatography. However, because biological samples consist of complex components, they suffer from the matrix effect, which seriously affects the accuracy, sensitivity, and reliability of the selected separation analysis technique. In addition to the matrix effect, the detection of trace components is challenging because the content of the analyte in the sample is usually very low. Moreover, reasonable strategies for sample enrichment and signal amplification for easy analysis are lacking. In response to the various issues described above, researchers have focused their attention on immuno-affinity technology with the aim of achieving efficient sample separation based on the specific recognition effect between antigens and antibodies. Following a long period of development, this technology is now widely used in fields such as disease diagnosis, bioimaging, food testing, and recombinant protein purification. Common immuno-affinity technologies include solid-phase extraction (SPE) magnetic beads, affinity chromatography columns, and enzyme linked immunosorbent assay (ELISA) kits. Immuno-affinity techniques can successfully reduce or eliminate the matrix effect; however, their applications are limited by a number of disadvantages, such as high costs, tedious fabrication procedures, harsh operating conditions, and ligand leakage. Thus, developing an effective and reliable method that can address the matrix effect remains a challenging endeavor. Similar to the interactions between antigens and antibodies as well as enzymes and substrates, biomimetic molecularly imprinted polymers (MIPs) exhibit high specificity and affinity. Furthermore, compared with many other biomacromolecules such as antigens and aptamers, MIPs demonstrate higher stability, lower cost, and easier fabrication strategies, all of which are advantageous to their application. Therefore, molecular imprinting technology (MIT) is frequently used in SPE, chromatographic separation, and many other fields. With the development of MIT, researchers have engineered different types of imprinting strategies that can specifically extract the target analyte in complex biological samples while simultaneously avoiding the matrix effect. Some traditional separation technologies based on MIP technology have also been studied in depth; the most common of these technologies include stationary phases used for chromatography and adsorbents for SPE. Analytical methods that combine MIT with highly sensitive detection technologies have received wide interest in fields such as disease diagnosis and bioimaging. In this review, we highlight the new MIP strategies developed in recent years, and describe the applications of MIT-based separation analysis methods in fields including chromatographic separation, SPE, diagnosis, bioimaging, and proteomics. The drawbacks of these techniques as well as their future development prospects are also discussed.


Assuntos
Impressão Molecular , Humanos , Cromatografia de Afinidade/métodos , Extração em Fase Sólida/métodos , Ensaio de Imunoadsorção Enzimática
11.
Wei Sheng Yan Jiu ; 53(3): 447-454, 2024 May.
Artigo em Chinês | MEDLINE | ID: mdl-38839587

RESUMO

OBJECTIVE: To develop and validate a solid phase extraction-ultra-high performance liquid chromatography-tandem mass spectrometry method for the determination of six bisphenols(bisphenol S, bisphenol F, bisphenol A, 2, 2'-methylenediphenol, bisphenol AF, bisphenol AP) in urine. METHODS: After enzymolysis of urine sample, the target substances were quickly purified and extracted by WAX solid phase extraction column. On ACQUITY BEH C_(18) column(2.1 mm×100 mm, 1.7 µm), the mobile phase of water and methanol was used to separate. Finally, multi-reaction detection was carried out under electrospray negative ion scanning, and quantification was carried out by internal standard method. RESULTS: The correlation coefficients(r) of the target compounds were all more than 0.998 in the range of 0.1-50.0 ng/mL, the linearity was good, and the detection limits were all lower than 0.1 ng/mL. The recoveries of the three standard concentrations(0.5, 5.0 and 50.0 ng/mL) were all between 80% and 120%, and the relative standard deviation was less than 20%(n=5). The standard reference material was detected and the concentration was within the reference range. CONCLUSION: This method can be used to detect six bisphenols in urine quickly and accurately, is suitable for the trace analysis of bisphenol compounds in human urine.


Assuntos
Compostos Benzidrílicos , Fenóis , Espectrometria de Massas em Tandem , Humanos , Fenóis/urina , Fenóis/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Compostos Benzidrílicos/urina , Extração em Fase Sólida/métodos , Sulfonas/urina
12.
J Chromatogr A ; 1726: 464965, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38733925

RESUMO

Aristolochic acids (AAs) naturally occurring in the herbal genus Aristolochia are associated with a high risk of kidney failure, multiple tumors and cancers. However, approaches with high selectivity and rapidity for measuring AAs in biological samples are still inadequate. Inspired by the mechanism of AAs-induced nephrotoxicity, we designed a hybrid magnetic polymer-porous agarose (denoted as MNs@SiO2M@DNV-A), mimicking the effect of basic and aromatic residues of organic anion transporter 1 (OAT1) for efficient enriching aristolochic acid I (AA I) and aristolochic acid II (AA II) in the plasma. The monomers of vinylbenzyl trimethylammonium chloride (VBTAC), N-vinyl-2-pyrrolidinone (NVP) and divinylbenzene (DVB) were employed to construct the polymer layer, which provided a selective adsorption for AAs by multiple interactions. The porous agarose shell contributed to remove interfering proteins in the plasma samples. A magnetic solid-phase extraction (MSPE) based on the proposed composite enhanced the selectivity toward AA I and AA II in the plasma samples. In combination of HPLC analysis, the proposed method was proved to be applicable to fast and specific quantification of AAs in blood samples, which was characterized by a good linearity, high sensitivity, acceptable recovery, excellent repeatability and satisfactory reusability.


Assuntos
Ácidos Aristolóquicos , Compostos de Amônio Quaternário , Sefarose , Extração em Fase Sólida , Ácidos Aristolóquicos/química , Ácidos Aristolóquicos/isolamento & purificação , Ácidos Aristolóquicos/sangue , Sefarose/química , Extração em Fase Sólida/métodos , Compostos de Amônio Quaternário/química , Cromatografia Líquida de Alta Pressão/métodos , Porosidade , Limite de Detecção , Animais , Humanos , Polímeros/química , Adsorção , Reprodutibilidade dos Testes
13.
Mar Pollut Bull ; 203: 116444, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38705002

RESUMO

An efficient and sensitivity approach, which combines solid-phase extraction or ultrasonic extraction for pretreatment, followed by ultra-performance liquid chromatography-tandem mass spectrometry, has been established to simultaneously determine eight lipophilic phycotoxins and one hydrophilic phycotoxin in seawater, sediment and biota samples. The recoveries and matrix effects of target analytes were in the range of 61.6-117.3 %, 55.7-121.3 %, 57.5-139.9 % and 82.6 %-95.0 %, 85.8-106.8 %, 80.7 %-103.3 % in seawater, sediment, and biota samples, respectively. This established method revealed that seven, six and six phycotoxins were respectively detected in the Beibu Gulf, with concentrations ranging from 0.14 ng/L (okadaic acid, OA) to 26.83 ng/L (domoic acid, DA) in seawater, 0.04 ng/g (gymnodimine-A, GYM-A) to 2.75 ng/g (DA) in sediment and 0.01 ng/g (GYM-A) to 2.64 ng/g (domoic acid) in biota samples. These results suggest that the presented method is applicable for the simultaneous determination of trace marine lipophilic and hydrophilic phycotoxins in real samples.


Assuntos
Biota , Monitoramento Ambiental , Toxinas Marinhas , Água do Mar , Extração em Fase Sólida , Toxinas Marinhas/análise , Monitoramento Ambiental/métodos , Água do Mar/química , Sedimentos Geológicos/química , Poluentes Químicos da Água/análise , Espectrometria de Massas em Tandem , Interações Hidrofóbicas e Hidrofílicas , Ácido Caínico/análogos & derivados , Ácido Caínico/análise , Compostos Heterocíclicos com 3 Anéis , Hidrocarbonetos Cíclicos , Iminas
14.
Environ Sci Technol ; 58(22): 9828-9839, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38785362

RESUMO

Pharmaceuticals and their human metabolites are contaminants of emerging concern in the aquatic environment. Most monitoring studies focus on a limited set of parent compounds and even fewer metabolites. However, more than 50% of the most consumed pharmaceuticals are excreted in higher amounts as metabolites than as parents, as confirmed by a literature analysis within this study. Hence, we applied a wide-scope suspect screening approach to identify human pharmaceutical metabolites in wastewater influent from three Swiss treatment plants. Based on consumption amounts and human metabolism data, a suspect list comprising 268 parent compounds and over 1500 metabolites was compiled. Online solid phase extraction combined with liquid chromatography coupled to high-resolution tandem mass spectrometry was used to analyze the samples. Data processing, annotation, and structure elucidation were achieved with various tools, including molecular networking as well as SIRIUS/CSI:FingerID and MetFrag for MS2 spectra rationalization. We confirmed 37 metabolites with reference standards and 16 by human liver S9 incubation experiments. More than 25 metabolites were detected for the first time in influent wastewater. Semiquantification with MS2Quant showed that metabolite to parent concentration ratios were generally lower compared to literature expectations, probably due to further metabolite transformation in the sewer system or limitations in the metabolite detection. Nonetheless, metabolites pose a large fraction to the total pharmaceutical contribution in wastewater, highlighting the need for metabolite inclusion in chemical risk assessment.


Assuntos
Águas Residuárias , Poluentes Químicos da Água , Águas Residuárias/química , Humanos , Poluentes Químicos da Água/metabolismo , Espectrometria de Massas em Tandem , Preparações Farmacêuticas/metabolismo , Cromatografia Líquida , Monitoramento Ambiental/métodos , Extração em Fase Sólida
15.
Molecules ; 29(10)2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38792139

RESUMO

In the past few decades, considerable scientific strides have been made in the subject of drug analysis in human biological samples. However, the risk caused by incorrect drug plasma levels in patients still remains an important concern. This review paper attempts to investigate the advances made over the last ten years in common sample preparation techniques (SPT) for biological samples based on solid sorbents, including solid-phase extraction (SPE) and solid-phase micro-extraction (SPME), and in particular in the field of molecularly imprinted polymers (MIPs), including non-stimuli-responsive and stimuli-responsive adsorbents. This class of materials is known as 'smart adsorbents', exhibiting tailored responses to various stimuli such as magnetic fields, pH, temperature, and light. Details are provided on how these advanced SPT are changing the landscape of modern drug analysis in their coupling with liquid chromatography-mass spectrometry (LC-MS) analytical techniques, a general term that includes high-performance liquid chromatography (HPLC) and ultra-high performance liquid chromatography (UHPLC), as well as any variation of MS, such as tandem (MS/MS), multiple-stage (MSn), and high-resolution (HRMS) mass spectrometry. Some notes are also provided on coupling with less-performing techniques, such as high-performance liquid chromatography with ultraviolet (HPLC-UV) and diode array detection (HPLC-DAD) detection. Finally, we provide a general review of the difficulties and benefits of the proposed approaches and the future prospects of this research area.


Assuntos
Extração em Fase Sólida , Humanos , Extração em Fase Sólida/métodos , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Microextração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Polímeros Molecularmente Impressos/química , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos
16.
Molecules ; 29(10)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38792152

RESUMO

Taxus, as a globally prevalent evergreen tree, contains a wealth of bioactive components that play a crucial role in the pharmaceutical field. Taxus extracts, defined as a collection of one or more bioactive compounds extracted from the genus Taxus spp., have become a significant focus of modern cancer treatment research. This review article aims to delve into the scientific background of Taxus extracts and their considerable value in pharmaceutical research. It meticulously sifts through and compares various advanced extraction techniques such as supercritical extraction, ultrasound extraction, microwave-assisted extraction, solid-phase extraction, high-pressure pulsed electric field extraction, and enzymatic extraction, assessing each technology's advantages and limitations across dimensions such as extraction efficiency, extraction purity, economic cost, operational time, and environmental impact, with comprehensive analysis results presented in table form. In the area of drug formulation design, this paper systematically discusses the development strategies for solid, liquid, and semi-solid dosage forms based on the unique physicochemical properties of Taxus extracts, their intended medical uses, and specific release characteristics, delving deeply into the selection of excipients and the critical technical issues in the drug preparation process. Moreover, the article looks forward to the potential directions of Taxus extracts in future research and medical applications, emphasizing the urgency and importance of continuously optimizing extraction methods and formulation design to enhance treatment efficacy, reduce production costs, and decrease environmental burdens. It provides a comprehensive set of preparation techniques and formulation optimization schemes for researchers in cancer treatment and other medical fields, promoting the application and development of Taxus extracts in pharmaceutical sciences.


Assuntos
Extratos Vegetais , Taxus , Taxus/química , Extratos Vegetais/química , Humanos , Composição de Medicamentos/métodos , Extração em Fase Sólida/métodos
17.
Molecules ; 29(10)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38792172

RESUMO

Pyrethroid pesticides (PYRs) have found widespread application in agriculture for the protection of fruit and vegetable crops. Nonetheless, excessive usage or improper application may allow the residues to exceed the safe limits and pose a threat to consumer safety. Thus, there is an urgent need to develop efficient technologies for the elimination or trace detection of PYRs from vegetables. Here, a simple and efficient magnetic solid-phase extraction (MSPE) strategy was developed for the simultaneous purification and enrichment of five PYRs in vegetables, employing the magnetic covalent organic framework nanomaterial COF-SiO2@Fe3O4 as an adsorbent. COF-SiO2@Fe3O4 was prepared by a straightforward solvothermal method, using Fe3O4 as a magnetic core and benzidine and 3,3,5,5-tetraaldehyde biphenyl as the two building units. COF-SiO2@Fe3O4 could effectively capture the targeted PYRs by virtue of its abundant π-electron system and hydroxyl groups. The impact of various experimental parameters on the extraction efficiency was investigated to optimize the MSPE conditions, including the adsorbent amount, extraction time, elution solvent type and elution time. Subsequently, method validation was conducted under the optimal conditions in conjunction with gas chromatography-mass spectrometry (GC-MS). Within the range of 5.00-100 µg·kg-1 (1.00-100 µg·kg-1 for bifenthrin and 2.5-100 µg·kg-1 for fenpropathrin), the five PYRs exhibited a strong linear relationship, with determination coefficients ranging from 0.9990 to 0.9997. The limits of detection (LODs) were 0.3-1.5 µg·kg-1, and the limits of quantification (LOQs) were 0.9-4.5 µg·kg-1. The recoveries were 80.2-116.7% with relative standard deviations (RSDs) below 7.0%. Finally, COF-SiO2@Fe3O4, NH2-SiO2@Fe3O4 and Fe3O4 were compared as MSPE adsorbents for PYRs. The results indicated that COF-SiO2@Fe3O4 was an efficient and rapid selective adsorbent for PYRs. This method holds promise for the determination of PYRs in real samples.


Assuntos
Praguicidas , Piretrinas , Dióxido de Silício , Extração em Fase Sólida , Verduras , Extração em Fase Sólida/métodos , Dióxido de Silício/química , Verduras/química , Piretrinas/isolamento & purificação , Piretrinas/análise , Piretrinas/química , Praguicidas/isolamento & purificação , Praguicidas/química , Praguicidas/análise , Cromatografia Gasosa-Espectrometria de Massas , Adsorção , Contaminação de Alimentos/análise , Limite de Detecção , Resíduos de Praguicidas/análise , Resíduos de Praguicidas/isolamento & purificação , Compostos Férricos/química , Cobalto
18.
Molecules ; 29(10)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38792205

RESUMO

This research presents a new, eco-friendly, and swift method combining solid-phase extraction and hydrophobic deep eutectic solvents (DES) with high-performance liquid chromatography (SPE-DES-HPLC) for extracting and quantifying catechin and epicatechin in Shanxi aged vinegar (SAV). The parameters, such as the elution solvent type, the XAD-2 macroporous resin dosage, the DES ratio, the DES volume, the adsorption time, and the desorption time, were optimized via a one-way experiment. A central composite design using the Box-Behnken methodology was employed to investigate the effects of various factors, including 17 experimental runs and the construction of three-dimensional response surface plots to identify the optimal conditions. The results show that the optimal conditions were an HDES (tetraethylammonium chloride and octanoic acid) ratio of 1:3, an XAD-2 macroporous resin dosage of 188 mg, and an adsorption time of 11 min. Under these optimal conditions, the coefficients of determination of the method were greater than or equal to 0.9917, the precision was less than 5%, and the recoveries ranged from 98.8% to 118.8%. The environmentally friendly nature of the analytical process and sample preparation was assessed via the Analytical Eco-Scale and AGREE, demonstrating that this method is a practical and eco-friendly alternative to conventional determination techniques. In summary, this innovative approach offers a solid foundation for the assessment of flavanol compounds present in SAV samples.


Assuntos
Ácido Acético , Catequina , Solventes Eutéticos Profundos , Interações Hidrofóbicas e Hidrofílicas , Extração em Fase Sólida , Cromatografia Líquida de Alta Pressão/métodos , Extração em Fase Sólida/métodos , Ácido Acético/química , Catequina/química , Catequina/análise , Solventes Eutéticos Profundos/química , Adsorção
19.
Anal Methods ; 16(22): 3587-3596, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38804081

RESUMO

A magnetic, mesoporous core/shell structured Fe3O4@SiO2@mSiO2 nanocomposite was synthesized and employed as a magnetic solid phase extraction (MSPE) sorbent for the determination of trace sulfonamides (SAs) in food samples. The synthesized nanocomposite was characterized by transmission electron microscopy, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, thermogravimetric analysis, X-ray diffraction, N2 sorption analysis and vibrating sample magnetometry. The results showed that Fe3O4@SiO2@mSiO2 possessed a mesoporous structure with a large surface area. Batch experiments were carried out to investigate the adsorption ability for SAs. Fe3O4@SiO2@mSiO2 showed fast kinetics and high adsorption capacity, and the pseudo-second-order model and Langmuir adsorption isotherm are well fitted with the experimental data, indicating that chemical adsorption might be the rate-limiting step. Moreover, the high adsorption capacity can be maintained for at least 8 runs, indicating excellent stability and reusability. The proposed method exhibited good linearity in the range of 0.2-500 µg L-1, the R2 values of all the analytes were greater than 0.99 and the LODs were all lower than 0.2 µg L-1. Furthermore, real food samples were successfully analyzed with Fe3O4@SiO2@mSiO2 and high recoveries varying from 89.7% and 110.6% were obtained with low relative standard deviations ranging from 1.78% to 6.91%. The Fe3O4@SiO2@mSiO2 magnetic nanocomposite is a promising sorbent for the efficient extraction of SAs from complex food samples.


Assuntos
Nanopartículas de Magnetita , Dióxido de Silício , Extração em Fase Sólida , Sulfonamidas , Sulfonamidas/isolamento & purificação , Sulfonamidas/análise , Sulfonamidas/química , Nanopartículas de Magnetita/química , Adsorção , Dióxido de Silício/química , Extração em Fase Sólida/métodos , Contaminação de Alimentos/análise , Análise de Alimentos/métodos , Porosidade , Nanocompostos/química , Limite de Detecção
20.
Artigo em Inglês | MEDLINE | ID: mdl-38749101

RESUMO

A magnetic composite (Fe3O4@SiO2@PNIPAM-co-NHMA) with high adsorption capacity and recoverability was developed for the enrichment and determination of flavonoids in Scutellaria Radix (SR). A magnetic solid-phase extraction (MSPE) technique using Fe3O4@SiO2@PNIPAM-co-NHMA absorbent in combination with high-performance liquid chromatography (HPLC) was developed for selectively enrichment and determination of the biologically active flavonoids in the aqueous extract of SR, including baicalein, baicalin, wogonoside and wogonin. Under the optimized experimental conditions, the magnetic adsorbent could adsorb up to 77.0 ± 0.98 % - 98.15 ± 0.15 % of four representative flavonoids from SR, with elution rates varying from 55.10 ± 0.25 % to 91.94 ± 1.85 %. The limits of detection (LOD) and limits of quantitation (LOQ) were 0.01-0.35 µg/mL and 0.03-0.98 µg/mL, respectively. In addition, it remained effective after six replicates, demonstrating its potential as a recoverable adsorbent for enriching flavonoids in traditional Chinese medicine.


Assuntos
Flavonoides , Limite de Detecção , Scutellaria baicalensis , Extração em Fase Sólida , Flavonoides/química , Flavonoides/isolamento & purificação , Flavonoides/análise , Scutellaria baicalensis/química , Cromatografia Líquida de Alta Pressão/métodos , Adsorção , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodos , Nanopartículas de Magnetita/química , Medicamentos de Ervas Chinesas/química , Modelos Lineares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...