Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
J Chromatogr A ; 1652: 462384, 2021 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-34261021

RESUMO

Food analysis is a tremendously broad field that is constantly evolving. New methods have emerged to increase productivity, such as modern miniaturized and robotic analytical techniques. In this paper, a micro-solid-phase extraction system (µ-SPE) for clean-up was combined with a robotic autosampler to yield ready-to-analyze extracts. The system was evaluated for its applicability in routine laboratories. The new, automated, high-throughput µ-SPE clean-up method was applied to acetonitrile extracts and was developed for the analysis of pesticide residues in cereals by gas chromatography-Orbitrap mass spectrometry (GC-Orbitrap-MS). The µ-SPE clean-up efficiency was demonstrated in the removal of matrix-interfering components and in the recovery of pesticides. The sorbent bed mixture consisted of magnesium sulfate, primary-secondary amine, C18, and CarbonX, and effectively retained matrix components without loss of target analytes. Analysis of five types of cereals (barley, oat, rice, rye, and wheat) by GC-Orbitrap-MS showed that the method removed more than 70% of matrix components. The clean-up method was validated for 170 pesticides in rye, 159 pesticides in wheat, 142 pesticides in barley, 130 pesticides in oat, and 127 pesticides in rice. Spike recovery values were 70-120% for all pesticides and the repeatability, calculated as the relative standard deviation, was less than 20%. The limits of quantitation achieved were 0.005 mg kg-1 for almost all analytes, ensuring compliance with the maximum residue limits.


Assuntos
Grão Comestível , Análise de Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Resíduos de Praguicidas , Extração em Fase Sólida , Grão Comestível/química , Análise de Alimentos/métodos , Análise de Alimentos/normas , Resíduos de Praguicidas/análise , Resíduos de Praguicidas/isolamento & purificação , Extração em Fase Sólida/normas
2.
Plant Commun ; 1(3): 100047, 2020 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33367242

RESUMO

One of the hottest topics in plant hormone biology is the crosstalk mechanisms, whereby multiple classes of phytohormones interplay with each other through signaling networks. To better understand the roles of hormonal crosstalks in their complex regulatory networks, it is of high significance to investigate the spatial and temporal distributions of multiple -phytohormones simultaneously from one plant tissue sample. In this study, we develop a high-sensitivity and high-throughput method for the simultaneous quantitative analysis of 44 phytohormone compounds, covering currently known 10 major classes of phytohormones (strigolactones, brassinosteroids, gibberellins, auxin, abscisic acid, jasmonic acid, salicylic acid, cytokinins, ethylene, and polypeptide hormones [e.g., phytosulfokine]) from only 100 mg of plant sample. These compounds were grouped and purified separately with a tailored solid-phase extraction procedure based on their physicochemical properties and then analyzed by LC-MS/MS. The recoveries of our method ranged from 49.6% to 99.9% and the matrix effects from 61.8% to 102.5%, indicating that the overall sample pretreatment design resulted in good purification. The limits of quantitation (LOQs) of our method ranged from 0.06 to 1.29 pg/100 mg fresh weight and its precision was less than 13.4%, indicating high sensitivity and good reproducibility of the method. Tests of our method in different plant matrices demonstrated its wide applicability. Collectively, these advantages will make our method helpful in clarifying the crosstalk networks of phytohormones.


Assuntos
Química Analítica/normas , Cromatografia Líquida/normas , Eficiência , Guias como Assunto , Reguladores de Crescimento de Plantas/análise , Extração em Fase Sólida/normas , Espectrometria de Massas em Tandem/normas , Reprodutibilidade dos Testes
3.
Drug Test Anal ; 12(11-12): 1570-1580, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32959982

RESUMO

The possibility of nutritional supplement contamination with minute amounts of the selective androgen receptor modulator (SARM) ostarine has become a major concern for athletes and result managing authorities. In case of an adverse analytical finding (AAF), affected athletes need to provide conclusive information, demonstrating that the test result originates from a contamination scenario rather than doping. The aim of this research project was to study the elimination profiles of microdosed ostarine and characterize the time-dependent urinary excretion of the drug and selected metabolites. Single- and multi-dose administration studies with 1, 10, and 50 µg of ostarine were conducted, and collected urine samples were analyzed by LC-MS/MS following solid-phase extraction or enzymatic hydrolysis combined with liquid-liquid extraction. In the post-administration samples, both the maximum urine concentrations/abundance ratios and detection times of ostarine and its phase-I and phase-II metabolites were found to correlate with the administered drug dose. With regard to the observed maximum levels of ostarine, the time points of peak urinary concentrations/abundance ratios, and detection windows, a high inter-individual variation was observed. However, the study demonstrated that a single oral dose of as little as 1 µg can be detected for up to 9 (5) days by monitoring ostarine (glucuronide), and hydroxylated metabolites (especially M1a) appear to offer a considerably shorter detection window. The obtained data on ostarine (metabolite) detection times and urinary concentrations following different administration schemes support the interpretation of AAFs, in particular when scenarios of proven supplement contamination are discussed and supplement administration protocols exist.


Assuntos
Anilidas/administração & dosagem , Anilidas/urina , Suplementos Nutricionais/análise , Ingestão de Alimentos/fisiologia , Contaminação de Alimentos/análise , Detecção do Abuso de Substâncias/métodos , Administração Oral , Anabolizantes/administração & dosagem , Anabolizantes/urina , Dopagem Esportivo/prevenção & controle , Relação Dose-Resposta a Droga , Ingestão de Alimentos/efeitos dos fármacos , Humanos , Extração Líquido-Líquido/métodos , Extração Líquido-Líquido/normas , Masculino , Receptores Androgênicos/metabolismo , Extração em Fase Sólida/métodos , Extração em Fase Sólida/normas , Detecção do Abuso de Substâncias/normas , Iogurte/análise
4.
J Pharm Biomed Anal ; 185: 113214, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32126444

RESUMO

A novel analytical method is presented for 12 target pharmaceutical and personal care products (PPCPs), belonging to different classes like antibiotics, non-steroid anti-inflammatory drugs, parabens, UV-filters, plasticizer, and antibacterials. The method development comprises of solid-phase extraction (SPE) with lipophilic-hydrophilic material balanced Oasis HLB cartridge, followed by reverse-phase liquid chromatography interfaced to linear ion trap tandem mass spectrometry (LC-MS/MS) with electrospray ionization. Chromatographic separation was achieved with a gradient elution of 25 min run time using 5 mM ammonium acetate buffer with pH adjustment using acetic acid. In addition, cost effective organic solvent with buffer used together as the mobile phase with Chromatopak C18 column (150 mm × 4 mm, 5-µm,) in negative ionization mode. Recoveries ranged from 61.74 % to 119.89 % for most of the compounds. Matrix-matched calibration curves were used for counterbalancing the matrix effects for all the analytes, and ibuprofen D3 internal standard was used for assessing the effectiveness of extraction technique and monitoring the recovery of sample analysis. Simple empirical weighted linear regression curve technique was adopted practically for each analysis in enhancing the analyte accuracy at lower quantification level. The 1/x2 model was selected as the best suitable model for quantification of analytes, which can be evaluated by deviation from back-calculated concentration in terms of percentage relative error (%RE). Weighted calibration curves with regression value for most of the compounds were ≥ 0.98, except triclosan with a regression value ≥ 0.93. Precision showed as % relative standard deviation (%RSD) were always below 15.0 %. Accuracy-test was evaluated by the statistical one-sample t-test and no significant difference was observed between nominal and experimental value. The limit of quantification (LOQ) ranged from 3.0 ng/mL (BP1) to 1000 ng/mL (naproxen). Finally, the validated method was used for the first time to determine target analytes in surface water samples collected from Arkavathi river flowing across southern India's Bengaluru city.


Assuntos
Monitoramento Ambiental/métodos , Espectrometria de Massas em Tandem/métodos , Poluentes Químicos da Água/análise , Poluição Química da Água/prevenção & controle , Água/análise , Antibacterianos/análise , Anti-Inflamatórios não Esteroides/análise , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Cromatografia de Fase Reversa/métodos , Cromatografia de Fase Reversa/normas , Cosméticos/análise , Índia , Limite de Detecção , Parabenos/análise , Plastificantes/análise , Rios , Extração em Fase Sólida/métodos , Extração em Fase Sólida/normas , Espectrometria de Massas em Tandem/normas , Água/química
5.
Mikrochim Acta ; 187(1): 88, 2020 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-31897612

RESUMO

Magnetic hierarchical nickel/nickel oxide/carbon nanorods (Ni/NiO@C) were prepared via the pyrolysis of a metal-organic framework containing nickel(II) nickel (Ni-MOF; Ni3(BTC)2) under argon atmosphere. In this material, magnetic Ni/NiO@C nanoparticles are embedded in porous carbon nanorods, and the morphology is similar to that of the original Ni-MOF precursor. The synthesized nanorods were applied as magnetic sorbents in the solid-phase extraction of five benzoylurea insecticides (flufenoxuron, chlorbenzuron, teflubenzuron, diflubenzuron and triflumuron), and their performance was evaluated under optimized conditions. The results show that the material exhibits high extraction recoveries from spiked samples (82.9%-107.6%) and linear response in the range of 0.2-450 µg·L-1. It is also characterized by relatively low limits of detection (50-100 ng·mL-1) at a signal-to-noise ratio of 3. The sorbent is chemically stable and can be repeatedly recycled, with little decline in extraction capacity after 20 cycles of reuse. The method was successfully applied to the quantification of benzoylureas in tea, wolfberry, millet, and oat samples, and it showed high extraction efficiency. Graphical abstractSchematic representation of the synthesis of magnetic hierarchical nickel/nickel oxide/carbon nanorods derived from Ni-MOF. The material is employed as a sorbent for the magnetic solid-phase extraction of benzoylurea insecticides.


Assuntos
Inseticidas/isolamento & purificação , Magnetismo , Estruturas Metalorgânicas/química , Nanotubos/química , Cromatografia Líquida de Alta Pressão , Inseticidas/análise , Níquel/química , Compostos de Fenilureia/análise , Compostos de Fenilureia/química , Compostos de Fenilureia/isolamento & purificação , Extração em Fase Sólida/métodos , Extração em Fase Sólida/normas
6.
Clin Chim Acta ; 503: 210-217, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31794770

RESUMO

Rejection and toxicity occur despite monitoring of tacrolimus blood levels during clinical routine. The intracellular concentration in lymphocytes could be a better reflection of the tacrolimus exposure. Four extraction methods for tacrolimus in peripheral blood mononuclear cells were validated and evaluated with UHPLC-MS/MS. Methods based on protein precipitation (method 1), solid phase extraction (method 2), phospholipids and proteins removal (method 3) and liquid-liquid extraction (method 4) were evaluated on linearity, lower limit of quantification (LLOQ), imprecision and bias. Validation was completed for the methods within these requirements, adding matrix effect and recovery. Linearity was 0.126 (LLOQ)-15 µg/L, 0.504 (LLOQ)-15 µg/L and 0.298 (LLOQ)-15 µg/L with method 1, 2 and 3, respectively. With method 4 non-linearity and a LLOQ higher than 0.504 µg/L were observed. Inter-day imprecision and bias were ≤4.6%, ≤10.9%; ≤6.8%, ≤-11.2%; ≤9.4%, ≤10.3% and ≤44.6%, ≤23.1%, respectively, with methods 1, 2, 3 and 4. Validation was completed for method 1 and 3 adding matrix effect (7.6%; 15.0%) and recovery (8.9%; 10.8%), respectively. The most suitable UHPLC-MS/MS method for quantification of intracellular tacrolimus was protein precipitation due to the best performance characteristics and the least time-consuming rate and complexity.


Assuntos
Leucócitos Mononucleares/química , Manejo de Espécimes/métodos , Tacrolimo/análise , Precipitação Química , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Lipídeos/isolamento & purificação , Extração Líquido-Líquido/normas , Proteínas/isolamento & purificação , Extração em Fase Sólida/normas , Manejo de Espécimes/normas , Espectrometria de Massas em Tandem/métodos
7.
Molecules ; 24(6)2019 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-30871257

RESUMO

Fabric phase sorptive extraction, an innovative integration of solid phase extraction and solid phase microextraction principles, has been combined with gas chromatography-mass spectrometry for the rapid extraction and determination of nineteen organochlorine pesticides in various fruit juices and water samples. FPSE consolidates the advanced features of sol-gel derived extraction sorbents with the rich surface chemistry of cellulose fabric substrate, which could extract the target analytes directly from the complex sample matrices, substantially simplifying the sample preparation operation. Important FPSE parameters, including sorbent chemistry, extraction time, stirring speed, type and volume of back-extraction solvent, and back-extraction time have been optimized. Calibration curves were obtained in a concentration range of 0.1⁻500 ng/mL. Under optimum conditions, limits of detection were obtained in a range of 0.007⁻0.032 ng/mL with satisfactory precision (RSD < 6%). The relative recoveries obtained by spiking organochlorine pesticides in water and selected juice samples were in the range of 91.56⁻99.83%. The sorbent sol-gel poly(ethylene glycol)-poly(propylene glycol)-poly(ethylene glycol) was applied for the extraction and preconcentration of organochlorine pesticides in aqueous and fruit juice samples prior to analysis with gas chromatography-mass spectrometry. The results demonstrated that the present method is simple, rapid, and precise for the determination of organochlorine pesticides in aqueous samples.


Assuntos
Sucos de Frutas e Vegetais/análise , Hidrocarbonetos Clorados/análise , Resíduos de Praguicidas/análise , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/análise , Calibragem , Contaminação de Alimentos/análise , Cromatografia Gasosa-Espectrometria de Massas , Extração em Fase Sólida/normas , Microextração em Fase Sólida/métodos , Microextração em Fase Sólida/normas , Água/química
8.
J Chromatogr A ; 1569: 70-78, 2018 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-30054128

RESUMO

In this study a novel "yarn-in-tube" configuration was introduced by packing cotton yarn inside stainless steel cartridge named packed yarn-in-tube solid phase extraction (yarn-IT-SPE) followed by high performance liquid chromatography. For the first time, cotton yarns were coated with a new polypyrrole@copper-chromium-iron ternary layered double hydroxide nanocomposite (Yarn@PPy@Cu-Cr-Fe LDH). The yarn@PPy@Cu-Cr-Fe LDH sorbent exhibited flexible substrate, high porosity, a three-dimensional, high sorbent loading, long lifetime, good mechanical stability, high anion-exchange capacity and large specific surface area as a result it is a good choice for the separation and preconcentration of acidic cholorophenols in honey samples. Several important factors affecting extraction efficiency such as extraction and desorption times, pH of solution and flow rates of the sample solution and eluent were investigated and optimized. Under the optimal conditions, the limits of detection were in the range of 0.05-0.07 µg L-1. This method showed good linearity for chlorophenols in the range of 0.10-500 µg L-1, with coefficients of determination better than 0.9989. The inter- and intra-assay precisions (RSD%, n = 5) were in the range of 3.2-4.9% and 2.1-3.6% at three concentration levels of 2, 10 and 20 µg L-1, respectively. The validated method was successfully applied for analysis of 4-chloro-, 2,4-dichloro-, and 2,4,6-trichloro phenols in honey samples.


Assuntos
Clorofenóis/análise , Fibra de Algodão , Análise de Alimentos/métodos , Mel/análise , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão , Análise de Alimentos/instrumentação , Nanocompostos/química , Polímeros/química , Pirróis/química , Extração em Fase Sólida/normas , Aço Inoxidável/química
9.
Electrophoresis ; 39(8): 1111-1118, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29349784

RESUMO

Novel magnetic molecularly imprinted polymers (MMIPs) with multiple-template based on silica were modified by four types of deep eutectic solvents (DESs) for the rapid simultaneous magnetic solid-phase extraction (MSPE) of tanshinone Ⅰ, tanshinone ⅡA, and cryptotanshinone from Salvia miltiorrhiza bunge; glycitein, genistein, and daidzein from Glycine max (Linn.) Merr; and epicatechin, epigallocatechin gallate, and epicatechin gallate from green tea, respectively. The synthesized materials were characterized by Fourier transform infrared spectroscopy and field emission scanning electron microscopy. Single factor experiments were to explore the relationship between the extraction efficiency and four factors (the sample solution pH, amount of DESs for modification, amount of adsorbent, and extraction time). It was showed that the DES4-MMIPs have better extraction ability than the MMIPs without DESs and the other three DESs-modified MMIPs. The best extraction recoveries with DES4-MMIP were tanshinone Ⅰ (85.57%), tanshinone ⅡA (80.58%), cryptotanshinone (92.12%), glycitein (81.65%), genistein (87.72%), daidzein (92.24%), epicatechin (86.43%), epigallocatechin gallate (80.92%), and epicatechin gallate (93.64%), respectively. The novel multiple-template MMIPs materials modified by DES for the rapid simultaneous MSPE of active compounds were proved to reduce the experimental steps than single-template technique, and increase the extraction efficiency.


Assuntos
Impressão Molecular/métodos , Extratos Vegetais/isolamento & purificação , Polímeros/química , Dióxido de Silício/química , Extração em Fase Sólida/métodos , Salvia miltiorrhiza/química , Extração em Fase Sólida/normas , Análise Espectral , Chá/química
10.
J Pharm Biomed Anal ; 150: 341-346, 2018 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-29287260

RESUMO

Propofol concentration in human plasma can be quantified by liquid chromatography coupled mass spectrometry. Sample preparation usually requires solid phase extraction to remove matrix components and enrich the analyte. To facilitate user-independent measurements and speed extraction, we developed and validated a fully automated high throughput in-line sample preparation system with direct injection into liquid chromatography coupled mass spectrometry. We assessed linearity of each method over the clinically relevant concentration range from 0.5µg/mL to 8µg/mL plasma concentration. R2 values were 0.99 for the automated process and 0.98 for manual sample preparation. The limit of detection was 6ng/mL and the lower limit of quantification was 18ng/mL for the automated method; for the manual process, the limit of detection was 1.58ng/mL and the lower limit of quantification was 4.79ng/mL. Intra-day precision for low, medium and high concentration range of the automated method was validated 4.14%, 9.68% and 3.04% relative standard deviation and 0.29%, 0.12% and 0.52% for the manual process. Carry over was 0.4% with the automated method, whereas there was no carry over with the manual method. Stability of plasma samples was tested with the manual method at concentrations of 1, 4, and 6µg/mL propofol and found to be stable over 150days at -20°C. The manual sample preparation method has successfully been transferred to a fully automated process with appropriate sensitivity and precision but the automatization failed with regard to trueness and working time due to lengthy sample preparation runtime. Therefore it is not suitable for daily use in a hospital laboratory e.g. for brain death diagnosis in the intensive care unit.


Assuntos
Anestésicos Intravenosos/sangue , Cromatografia Líquida , Espectrometria de Massas , Propofol/sangue , Extração em Fase Sólida , Automação Laboratorial , Calibragem , Cromatografia Líquida/normas , Humanos , Limite de Detecção , Modelos Lineares , Espectrometria de Massas/normas , Padrões de Referência , Reprodutibilidade dos Testes , Extração em Fase Sólida/normas , Fluxo de Trabalho
11.
J Pharm Biomed Anal ; 150: 396-405, 2018 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-29288965

RESUMO

The potential use of cholesterol esterases was tested to avoid alkaline hydrolysis for cleavage of plasma esterified oxysterols. The enzymatic hydrolysis was optimized by testing two sources of enzyme-Pseudomonas and bovine pancreas, presence of surfactants, incubation time and amount of enzyme. Free forms of 4ß-, 7-, 24-, 25- and 27-hydroxycholesterol (HC) as well 7-ketocholesterol (7-KC) were analyzed by liquid chromatography and mass-spectrometry using the deuterated internal standard, 25-HC(d6). Enzymatic hydrolysis was more effective using the Pseudomonas enzyme and in presence of surfactants. Compared to alkaline hydrolysis, it generated a cleaner chromatographic baseline and better recovery of the internal standard. Oxysterols were assayed with detection limits between 7 and 31 pg/mL. Interassay coefficients of variation were lower than 10% and extraction recovery efficiencies, higher than 90%. The procedure was used to characterize plasma levels of Cyp7b1-deficient rat, where it showed increased plasma levels of 7, 24 and 25-HC. Due to the low volume of sample required, it may be used in other animal models, particularly rodents, as well as in pediatric samples where sample amount is always a problem. Thus, the proposed new method offers mild enzymatic processing that greatly facilitates oxysterol determinations to delineate their role in physiopathology.


Assuntos
Proteínas de Bactérias/química , Cromatografia Líquida , Oxisteróis/sangue , Extração em Fase Sólida , Esterol Esterase/química , Espectrometria de Massas em Tandem , Animais , Animais Geneticamente Modificados , Calibragem , Cromatografia Líquida/normas , Família 7 do Citocromo P450/deficiência , Família 7 do Citocromo P450/genética , Humanos , Hidrólise , Masculino , Pseudomonas aeruginosa/enzimologia , Ratos Endogâmicos F344 , Padrões de Referência , Reprodutibilidade dos Testes , Extração em Fase Sólida/normas , Esteroide Hidroxilases/deficiência , Esteroide Hidroxilases/genética , Espectrometria de Massas em Tandem/normas
12.
J Chromatogr A ; 1524: 74-86, 2017 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-29031969

RESUMO

The influence of natural organic matter (NOM) on the solid-phase extraction (SPE) efficiency was investigated for legacy and emerging flame retardants (FRs; n=26) in surface water. Three different groups of FRs were analyzed: polybrominated diphenyl ethers (PBDEs), halogenated flame retardants (HFRs), and organophosphorus flame retardants (OPFRs). In addition, five sorbents (Amberlite XAD-2, Amberlite IRA-743, Oasis HLB, Chromabond HR-P, and Chromabond HR-X) were evaluated for the extraction of FRs (n=33) in water, of which Oasis HLB eluted with dichloromethane and acetone:n-hexane (1:1, v/v) provided the highest overall recoveries. In subsequent NOM experiments, where FRs were extracted from water containing different NOM concentrations, both increased and decreased extraction efficiency with increasing NOM level were observed. Physicochemical and semi-empirical quantum chemistry properties were calculated for the FRs and used for analyzing relations between FRs. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) showed that the FRs separated into four different groups based on their properties. The FRs within each group responded similarly to increasing NOM, while differences in behavior were observed between the groups. This suggests that the structural properties of micropollutants highly influence NOM-FR interaction mechanisms. For instance, at high NOM levels, recoveries decreased substantially for FRs containing a moiety that can form strong hydrogen bonds (such as the double-bonded oxygen in e.g., OPFRs). Many of the compounds showed maximum extraction efficiency at higher levels of NOM. This suggests that binding of NOM to the sorbent and subsequent interaction between sorbent-bound NOM and FRs is an important mechanism for extraction of micropollutants from surface waters.


Assuntos
Monitoramento Ambiental/métodos , Retardadores de Chama/isolamento & purificação , Extração em Fase Sólida/normas , Monitoramento Ambiental/normas , Retardadores de Chama/análise , Éteres Difenil Halogenados/análise , Éteres Difenil Halogenados/isolamento & purificação , Hexanos/química , Substâncias Húmicas/análise , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação
13.
Chemosphere ; 187: 376-384, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28863291

RESUMO

There are several established methods for the determination of naphthenic acids (NAs) in waters associated with oil sands mining operations. Due to their highly complex nature, measured concentration and composition of NAs vary depending on the method used. This study compared different common sample preparation techniques, analytical instrument methods, and analytical standards to measure NAs in groundwater and process water samples collected from an active oil sands operation. In general, the high- and ultrahigh-resolution methods, namely high performance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS) and Orbitrap mass spectrometry (Orbitrap-MS), were within an order of magnitude of the Fourier transform infrared spectroscopy (FTIR) methods. The gas chromatography mass spectrometry (GC-MS) methods consistently had the highest NA concentrations and greatest standard error. Total NAs concentration was not statistically different between sample preparation of solid phase extraction and liquid-liquid extraction. Calibration standards influenced quantitation results. This work provided a comprehensive understanding of the inherent differences in the various techniques available to measure NAs and hence the potential differences in measured amounts of NAs in samples. Results from this study will contribute to the analytical method standardization for NA analysis in oil sands related water samples.


Assuntos
Ácidos Carboxílicos/análise , Fracionamento Químico/métodos , Campos de Petróleo e Gás/química , Análise Espectral/métodos , Poluentes Químicos da Água/análise , Calibragem , Cromatografia Líquida de Alta Pressão , Cromatografia Gasosa-Espectrometria de Massas , Extração Líquido-Líquido/normas , Espectrometria de Massas , Métodos , Mineração , Extração em Fase Sólida/normas , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral/normas
14.
Food Chem ; 229: 814-819, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28372248

RESUMO

A simple and rapid gas chromatography with flame photometric detector (GC-FPD) determination method was developed to detect residue levels and investigate the dissipation pattern and safe use of fenitrothion in tomatoes. A modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) using an ethyl acetate-based extraction, followed by a dispersive solid-phase extraction (d-SPE) with primary-secondary amine (PSA) and graphite carbon black (GCB) for clean up, was applied prior to GC-FPD analysis. The method showed satisfactory linearity, recovery and precision. The limits of detection (LOD) and quantification (LOQ) were 0.005 and 0.01mg/kg, respectively. The residue levels of fenitrothion were best described by first order kinetics with a half-life of 2.2days in tomatoes. The potential health risks posed by fenitrothion were not significant, based on supervised residue trial data. The current findings could provide guidance for safe and reasonable use of fenitrothion in tomatoes and prevent health problems to consumers.


Assuntos
Fenitrotion/análise , Contaminação de Alimentos , Resíduos de Praguicidas/análise , Fotometria/normas , Solanum lycopersicum/química , Cromatografia Gasosa/métodos , Cromatografia Gasosa/normas , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/normas , Limite de Detecção , Fotometria/métodos , Reprodutibilidade dos Testes , Medição de Risco , Extração em Fase Sólida/métodos , Extração em Fase Sólida/normas
15.
J Chromatogr A ; 1499: 1-20, 2017 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-28408043

RESUMO

Solid phase extraction is gaining attention from separation scientists due to its high chromatographic utility. Though both grafted and impregnated forms of solid phase extraction resins are popular, the later is easy to make by impregnating a given organic extractant on to an inert solid support. Solid phase extraction on an impregnated support, also known as extraction chromatography, combines the advantages of liquid-liquid extraction and the ion exchange chromatography methods. On the flip side, the impregnated extraction chromatographic resins are less stable against leaching out of the organic extractant from the pores of the support material. Grafted resins, on the other hand, have a higher stability, which allows their prolong use. The goal of this article is a brief literature review on reported actinide and lanthanide separation methods based on solid phase extractants of both the types, i.e., (i) ligand impregnation on the solid support or (ii) ligand functionalized polymers (chemically bonded resins). Though the literature survey reveals an enormous volume of studies on the extraction chromatographic separation of actinides and lanthanides using several extractants, the focus of the present article is limited to the work carried out with amide based ligands, viz. monoamides, diamides and diglycolamides. The emphasis will be on reported applied experimental results rather than on data pertaining fundamental metal complexation.


Assuntos
Elementos da Série Actinoide/isolamento & purificação , Amidas/química , Elementos da Série dos Lantanídeos/isolamento & purificação , Extração em Fase Sólida , Ligantes , Polímeros/química , Extração em Fase Sólida/normas
16.
Artigo em Inglês | MEDLINE | ID: mdl-29668482

RESUMO

Herein, we present a simple and rapid high performance liquid chromatographic (HPLC) method with UV-detection for the direct determination of diazepam in whole blood and serum that can be used for monitoring diazepam levels in clinical samples analysis. The isolation of diazepam and the internal standard bromazepam from serum and whole blood samples was performed using solid phase extraction method with RP select B cartridges. The analytes were separated employing a reversed phase C8 column with a mobile phase composed of 0.1 % (V/V) triethylamine in water (pH 3.5) and acetonitrile (63:37, V/V). UV detection was carried out at 240 nm. Linearity was achieved in the range from 10.0-1000.0 ng/ml for serum and whole blood. The method was applied to spiked and real biological samples after an oral administration of 10 mg diazepam. In conclusion, the proposed method is simple, rapid and provides efficient clean-up of the complex biological matrix and high recovery of diazepam.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Diazepam/sangue , Monitoramento de Medicamentos/métodos , Hipnóticos e Sedativos/sangue , Extração em Fase Sólida/métodos , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Monitoramento de Medicamentos/normas , Humanos , Valor Preditivo dos Testes , Padrões de Referência , Reprodutibilidade dos Testes , Extração em Fase Sólida/normas , Espectrofotometria Ultravioleta
17.
J Pharm Biomed Anal ; 120: 322-32, 2016 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-26771131

RESUMO

A sensitive and specific method was developed and validated for the quantitation of maytansinoid (DM1) in human serum using on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS). Because DM1 contains a free thiol moiety, likely to readily dimerize or react with other thiol-containing molecules in serum, samples were pre-treated with a reducing agent [tris (2-carboxyethyl) phosphine] (TCEP) and further blocked with N-ethylmaleimide (NEM). The resulting samples were diluted with acetonitrile prior to the on-line solid phase extraction (SPE) on a C18 cartridge. A C18 (150×4.6mm ID 3µm particle size) column was used for chromatographic separation with a 10.0min HPLC gradient and DM1-NEM was detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer. DM1 concentrations were back-calculated from DM1-NEM amount found in the human serum samples. The quantitation range of the method was 0.200-200ng/mL when using 0.25mL serum. Within-run day precisions (n=6) were 0.9-4.4% and between-run day (3 days runs; n=18) precisions 2.5-5.6%. Method biases were between 3.5-14.5% across the whole calibration range. DM1-NEM exhibited sufficiently stability under all relevant analytical conditions and no DM1 losses from the ADC were observed. Finally, the assay was used for DM1 determination in human serum concentration after the intravenous administration of an investigational antibody drug conjugate (ADC) containing DM1 as payload.


Assuntos
Maitansina/análogos & derivados , Extração em Fase Sólida/métodos , Extração em Fase Sólida/normas , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Humanos , Infusões Intravenosas , Maitansina/administração & dosagem , Maitansina/sangue , Neoplasias/sangue , Neoplasias/tratamento farmacológico , Reprodutibilidade dos Testes
18.
J Pharm Biomed Anal ; 115: 443-9, 2015 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-26291788

RESUMO

HCV infection affects over 170 million people worldwide. The current standard for treatment of genotype 1 infection is the association of the first generation protease inhibitors boceprevir or telaprevir to ribavirin and peginterferon α. Although the response rate has been improved with these new drugs, some pharmacokinetic/pharmacodinamic issues emerged in the past years. To date, some analytical methods are available for the quantification of these drugs in plasma; however, the real active concentrations of the two drugs are those in hepatocytes. Being the withdrawal of hepatocytes too invasive, in this work we aimed to develop and validate a chromatographic method coupled with tandem mass spectrometry capable of quantifying boceprevir and telaprevir isomers in peripheral blood mononuclear cells, used as an "in-vivo" cellular model of compartmentalization. The method used an on-line solid phase extraction protocol based on the new OSM(®) platform and was fully validated following FDA guidelines. This method showed mean intra- and inter-day inaccuracy and imprecision both lower than 15%, high and stable recovery and contained matrix effect, with a run time of 6min, comprehensive of SPE extraction. The method was then applied on 35 real samples from patients treated with boceprevir or telaprevir, with good analytical performances, thus assessing its eligibility for a possible future routine use. Peculiar pharmacokinetic data have been observed, suggesting the usefulness of investigating intracellular pharmacokinetics of these drugs. Further studies will be required to test the correlation of intracellular concentrations with effectiveness and toxicity of triple therapy.


Assuntos
Antivirais/sangue , Cromatografia Líquida/métodos , Monitoramento de Medicamentos/métodos , Hepatite C/sangue , Leucócitos Mononucleares/química , Oligopeptídeos/sangue , Prolina/análogos & derivados , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Automação Laboratorial , Cromatografia Líquida/normas , Monitoramento de Medicamentos/normas , Hepatite C/diagnóstico , Hepatite C/tratamento farmacológico , Humanos , Isomerismo , Limite de Detecção , Modelos Lineares , Prolina/sangue , Padrões de Referência , Reprodutibilidade dos Testes , Extração em Fase Sólida/normas , Espectrometria de Massas em Tandem/normas , Fatores de Tempo
19.
J Anal Toxicol ; 39(7): 519-25, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25962609

RESUMO

A highly sensitive and fully validated method was developed for the quantification of buprenorphine in postmortem blood. After a two-step protein precipitation process using acetonitrile, buprenorphine was purified using mixed-mode (C8/cation exchange) solid-phase extraction cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted, concentrated and derivatized using N-methyl-N-trimethylsilyltrifluoroacetamide. The samples were analyzed using two-dimensional gas chromatography-mass spectrometry (2D GC-MS) in selective ion-monitoring mode. A low polarity Rxi(®)-5MS (30 m × 0.25 mm I.D. × 0.25 µm) was used as the primary column and the secondary column was a mid-polarity Rxi(®) -17Sil MS (15 m × 0.32 mm I.D. × 0.25 µm). The assay was linear from 1.0 to 50.0 ng/mL (r(2) > 0.99; n = 6). Intraday (n = 6) and interday (n = 9) imprecisions (percentage relative standard deviation, % RSD) were <5% and the average recovery was 60%. The limit of detection (LOD) of the method was 0.5 ng/mL and limit of quantification was 1.0 ng/mL. 2D GC-MS improved the LOD of buprenorphine by 20-fold compared with analysis on a conventional GC-MS. The method was highly selective with no interference from endogenous compounds or from 62 commonly encountered drugs. To prove method applicability to forensic postmortem cases, 14 authentic postmortem blood samples were analyzed.


Assuntos
Analgésicos Opioides/sangue , Buprenorfina/sangue , Toxicologia Forense/métodos , Cromatografia Gasosa-Espectrometria de Massas , Extração em Fase Sólida , Detecção do Abuso de Substâncias/métodos , Autopsia , Calibragem , Toxicologia Forense/normas , Cromatografia Gasosa-Espectrometria de Massas/normas , Humanos , Valor Preditivo dos Testes , Padrões de Referência , Reprodutibilidade dos Testes , Extração em Fase Sólida/normas , Detecção do Abuso de Substâncias/normas
20.
J Chromatogr A ; 1378: 19-31, 2015 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-25573188

RESUMO

Pressurized liquid extraction (PLE) and Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) extraction methods were optimized for the simultaneous determination of 50 pesticides in sediment, soils and sewage sludge. For QuEChERS development, several buffers and dispersive solid-phase extraction clean-up (dSPE) sorbents were tested. In the PLE method, several parameters affecting the extraction efficiency, such as organic solvent, amount of sample, cell size, temperature, pressure, static time, number of cycles and % of flush, as well as sorbent used for the on-line clean up, were also evaluated. PLE and QuEChERS were assessed and compared in obtained recoveries (33-89% versus 25-120%), number of pesticides for which recoveries are in the range of 80-100% (up to 13 versus up to 35) and cost of the approach. QuEChERS procedure was faster, cheaper and easier to perform. Recoveries were around 80% (at 50ngg(-1) d.w.) and the matrix effect was less than -20% using matrix-matched standard calibration curve for most of the analytes. The limits of quantification were between 0.1 and 10ngg(-1) (d.w.) except for alachlor and acetochlor. Repeatability and reproducibility were lower than 28% (%RSD, n=5). Soil, sediment and sludge samples, taken from the Túria River Basin, were analyzed by QuEChERS to determine pesticides. Chlorpyrifos (up to 65.3ngg(-1) d.w.) was the most frequent and at higher concentrations. Thiabendazole, imazalil, diazinon, pyriproxyfen, hexythiazox, carbofuran, isoproturon, terbuthylazine and terbumeton were also found in some samples.


Assuntos
Monitoramento Ambiental/métodos , Sedimentos Geológicos/química , Praguicidas/análise , Esgotos/química , Solo/química , Extração em Fase Sólida/normas , Reprodutibilidade dos Testes , Rios/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...