Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.652
Filtrar
1.
J Robot Surg ; 18(1): 241, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38833079

RESUMO

While partial nephrectomy offers oncologic efficacy and preserves renal function for T1 renal tumors, renal artery pseudoaneurysm (RAP) remains a rare but potentially life-threatening complication. This study compared RAP incidence across robotic-assisted (RAPN), laparoscopic (LPN), and open (OPN) partial nephrectomies in a large tertiary oncological center. This retrospective study analyzed 785 patients undergoing partial nephrectomy between 2012 and 2022 (398 RAPN, 122 LPN, 265 OPN). Data included demographics, tumor size/location, surgical type, clinical presentation, treatment, and post-operative outcomes. The primary outcome was RAP incidence, with secondary outcomes including presentation, treatment efficacy, and renal function. Seventeen patients (2.1%) developed RAP, presenting with massive hematuria (100%), hemorrhagic shock (5.8%), and clot retention (23%). The median onset was 12 days postoperatively. RAP occurred in 4 (1%), 4 (3.3%), and 9 (3.4%) patients following RAPN, LPN, and OPN, respectively (p = 0.04). Only operative length and surgical approach were independently associated with RAP. Selective embolization achieved immediate bleeding control in 94%, with one patient requiring a second embolization. No additional surgery or nephrectomy was needed. Estimated GFR at one year was similar across both groups (p = 0.53). RAPN demonstrated a significantly lower RAP incidence compared to LPN and OPN (p = 0.04). Emergency angiographic embolization proved effective, with no long-term renal function impact. This retrospective study lacked randomization and long-term follow-up. Further research with larger datasets and longer follow-ups is warranted. This study suggests that robotic-assisted partial nephrectomy is associated with a significantly lower risk of RAP compared to traditional approaches. Emergency embolization effectively treats RAP without compromising long-term renal function.


Assuntos
Falso Aneurisma , Neoplasias Renais , Laparoscopia , Nefrectomia , Complicações Pós-Operatórias , Artéria Renal , Procedimentos Cirúrgicos Robóticos , Humanos , Nefrectomia/métodos , Nefrectomia/efeitos adversos , Falso Aneurisma/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Laparoscopia/métodos , Laparoscopia/estatística & dados numéricos , Estudos Retrospectivos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Idoso , Artéria Renal/cirurgia , Neoplasias Renais/cirurgia , Incidência , Resultado do Tratamento , Embolização Terapêutica/métodos
2.
J Cardiothorac Surg ; 19(1): 326, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849846

RESUMO

BACKGROUND: Pedicle screw instrument surgeries can result in the development of aortic pseudoaneurysm, which is a rare yet potentially severe complication; therefore, the purpose of this work is to describe the case of pseudoaneurysm of the thoracic aorta caused by the severe migration of a pedicle screw after surgery. CASE PRESENTATION: We herein report a patient who underwent endovascular repair for the pseudoaneurysm of the descending thoracic aorta following thoracic vertebral fixation surgery. A 28-80 mm covered stent was initially inserted through the right femoral artery, and intraoperative aortography revealed a minor extravasation of contrast material. Subsequently, an additional 28-140 mm covered stent was implanted. The patient recovered well during the 8-year follow-up period. CONCLUSIONS: Vascular complications resulting from spinal surgery are severe and rare, necessitating early diagnosis and intervention.


Assuntos
Falso Aneurisma , Aorta Torácica , Procedimentos Endovasculares , Parafusos Pediculares , Humanos , Falso Aneurisma/cirurgia , Falso Aneurisma/etiologia , Procedimentos Endovasculares/métodos , Parafusos Pediculares/efeitos adversos , Masculino , Aorta Torácica/cirurgia , Stents/efeitos adversos , Seguimentos , Aneurisma da Aorta Torácica/cirurgia , Vértebras Torácicas/cirurgia , Complicações Pós-Operatórias/cirurgia , Pessoa de Meia-Idade
3.
PLoS One ; 19(6): e0304506, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38829913

RESUMO

BACKGROUND: The use of three-dimensional(3D) printing is broadly across many medical specialties. It is an innovative, and rapidly growing technology to produce custom anatomical models and medical conditions models for medical teaching, surgical planning, and patient education. This study aimed to evaluate the accuracy and feasibility of 3D printing in creating a superficial femoral artery pseudoaneurysm model based on CT scans for endovascular training. METHODS: A case of a left superficial femoral artery pseudoaneurysm was selected, and the 3D model was created using DICOM files imported into Materialise Mimics 22.0 and Materialise 3-Matic software, then printed using vat polymerization technology. Two 3D-printed models were created, and a series of comparisons were conducted between the 3D segmented images from CT scans and these two 3D-printed models. Ten comparisons involving internal diameters and angles of the specific anatomical location were measured. RESULTS: The study found that the absolute mean difference in diameter between the 3D segmented images and the 3D printed models was 0.179±0.145 mm and 0.216±0.143mm, respectively, with no significant difference between the two sets of models. Additionally, the absolute mean difference in angle was 0.99±0.65° and 1.00±0.91°, respectively, and the absolute mean difference in angle between the two sets of data was not significant. Bland-Altman analysis confirmed a high correlation in dimension measurements between the 3D-printed models and segmented images. Furthermore, the accuracy of a 3D-printed femoral pseudoaneurysm model was further tested through the simulation of a superficial femoral artery pseudoaneurysm coiling procedure using the Philips Azurion7 in the angiography room. CONCLUSIONS: 3D printing is a reliable technique for producing a high accuracy 3D anatomical model that closely resemble a patient's anatomy based on CT images. Additionally, 3D printing is a feasible and viable option for use in endovascular training and medical education. In general, 3D printing is an encouraging technology with diverse possibilities in medicine, including surgical planning, medical education, and medical device advancement.


Assuntos
Falso Aneurisma , Procedimentos Endovasculares , Estudos de Viabilidade , Artéria Femoral , Modelos Anatômicos , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Falso Aneurisma/diagnóstico por imagem , Humanos , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/anatomia & histologia , Procedimentos Endovasculares/métodos , Imageamento Tridimensional
4.
BMJ Case Rep ; 17(6)2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839418

RESUMO

A female underwent arthroscopic anterior cruciate ligament reconstruction (ACLR) via an outside-in drilling technique. At 4 weeks after surgery, she presented with a pulsatile painful mass on the lateral femoral condyle. Imaging confirmed a superolateral genicular artery pseudoaneurysm. Thrombin injections were administered twice, resulting in reduced size and minimal pain. This case emphasises the rare occurrence of pseudoaneurysms post-ACLR and highlights the importance of early detection and intervention for vascular complications. Although debated, we suggest tourniquet deflation before closure to facilitate identification and management of vascular issues. This report contributes valuable insights into managing pseudoaneurysms following ACLR.


Assuntos
Falso Aneurisma , Reconstrução do Ligamento Cruzado Anterior , Humanos , Falso Aneurisma/etiologia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Feminino , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Reconstrução do Ligamento Cruzado Anterior/métodos , Adulto , Artroscopia/efeitos adversos , Artroscopia/métodos , Complicações Pós-Operatórias , Trombina/administração & dosagem , Lesões do Ligamento Cruzado Anterior/cirurgia
5.
Cir Cir ; 92(3): 399-402, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38862120

RESUMO

Massive bleeding due to rupture of hypogastric artery pseudoaneurysm is an exceptional complication of colorectal anastomotic leakage. A 41-year-old woman with history of rectal cancer surgery, who debuted with massive rectorrhagia and hypovolemic shock due to rupture of a hypogastric artery pseudoaneurysm as a late complication of a colorectal anastomosis leak. The ruptured hypogastric artery pseudoaneurysm should be taken into account in the differential diagnosis of patients with massive rectorrhagia and history of colorectal anastomosis leak. Endovascular embolization is considered the first-line treatment.


La hemorragia masiva por rotura de un pseudoaneurisma de la arteria hipogástrica es una complicación muy rara de la fuga anastomótica colorrectal. Mujer de 41 años con antecedentes de cirugía por cáncer de recto, que debutó con un cuadro de rectorragias masivo y shock hipovolémico secundario a la rotura de un pseudoaneurisma de la arteria hipogástrica como complicación tardía de una fuga de la anastomosis colorrectal. La rotura de un pseudoaneurisma de la arteria hipogástrica se debe tener presente en el diagnostico diferencial de pacientes con rectorragia masiva y antecedentes de dehiscencia de anastomosis colorrectal. La embolización endovascular es actualmente el tratamiento de elección.


Assuntos
Fístula Anastomótica , Falso Aneurisma , Choque Hemorrágico , Humanos , Falso Aneurisma/etiologia , Feminino , Adulto , Fístula Anastomótica/etiologia , Choque Hemorrágico/etiologia , Aneurisma Roto/cirurgia , Reto/cirurgia , Neoplasias Retais/cirurgia , Colo/cirurgia , Colo/irrigação sanguínea , Anastomose Cirúrgica
6.
J Emerg Med ; 66(6): e723-e724, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38777708

RESUMO

A 49-year-old male with history of intravenous drug use presented to the Emergency Department with localized right arm swelling that has been slowly growing for months. On physical exam, there was a golf ball sized mass in the right antecubital fossa without overlying skin changes and no neurovascular deficits in the distal extremity. Point-of-care ultrasound (POCUS) was performed utilizing a water bath with visualization of bidirectional swirling in a round cavity adjacent to the brachial artery. Aneurysms are abnormal focal dilations that result from vascular wall defects. Ultrasound has been reported to have 94% sensitivity and 97% specificity for diagnosis of pseudoaneurysms. On color doppler ultrasound, pseudoaneurysm is characterized by the pathognomonic "yin-yang" sign. In the case of the 49-year-old male with a right antecubital mass and history of IVDU, the proposed mechanism of injury was trauma to the arterial wall secondary to auto-injection. POCUS has been found to improve identification of abscesses and its incorporation in patient evaluation can guide clinical management, prevent unwanted iatrogenic exsanguination, and determine whether there is a need for urgent vascular surgery intervention, particularly in high-risk patients.


Assuntos
Falso Aneurisma , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Masculino , Pessoa de Meia-Idade , Falso Aneurisma/diagnóstico por imagem , Ultrassonografia/métodos , Serviço Hospitalar de Emergência/organização & administração , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/lesões
7.
J Med Case Rep ; 18(1): 253, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38764047

RESUMO

BACKGROUND: Splenic artery pseudoaneurysm is a rare complication of recurrent pancreatitis usually presenting as an incidental finding on abdominal computed tomography. CASE PRESENTATION: We present the case of a 66-year-old north African male with a known history of previous pancreatitis who presented with upper gastrointestinal bleeding along with recurrent epigastric pain for 3 days. Investigations did not reveal any particular pancreatitis etiology. Computed tomography of the abdomen with contrast showed splenic artery pseudoaneurysm along with findings suggestive of acute pancreatitis. Upper and lower endoscopies failed to identify gastrointestinal the bleed source. The patient underwent intervention radiology embolization of the aneurysm sac with multiple coils via right retrograde common femoral artery-celiac access. The patient was discharged with a plan for capsule endoscopy in outpatient setting. CONCLUSION: Splenic artery pseudoaneurysm is a life-threatening complication and carries a high mortality rate if left untreated. Prompt identification through various imaging modalities, followed by urgent intervention, is crucial to avoid adverse outcomes.


Assuntos
Falso Aneurisma , Embolização Terapêutica , Artéria Esplênica , Tomografia Computadorizada por Raios X , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/terapia , Masculino , Artéria Esplênica/diagnóstico por imagem , Idoso , Pancreatite/complicações , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Dor Abdominal/etiologia , Resultado do Tratamento
8.
J Am Coll Cardiol ; 83(19): 1902-1916, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38719370

RESUMO

Postinfarction ventricular free-wall rupture is a rare mechanical complication, accounting for <0.01% to 0.02% of cases. As an often-catastrophic event, death typically ensues within minutes due to sudden massive hemopericardium resulting in cardiac tamponade. Early recognition is pivotal, and may allow for pericardial drainage and open surgical repair as the only emergent life-saving procedure. In cases of contained rupture with pseudo-aneurysm (PSA) formation, hospitalization with subsequent early surgical intervention is warranted. Not uncommonly, PSA may go unrecognized in asymptomatic patients and diagnosed late during subsequent cardiac imaging. In these patients, the unsettling risk of complete rupture demands early surgical repair. Novel developments, in the field of transcatheter-based therapies and multimodality imaging, have enabled percutaneous PSA repair as a feasible alternate strategy for patients at high or prohibitive surgical risk. Contemporary advancements in the diagnosis and treatment of postmyocardial infarction ventricular free-wall rupture and PSA are provided in this review.


Assuntos
Falso Aneurisma , Ruptura Cardíaca Pós-Infarto , Infarto do Miocárdio , Humanos , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Infarto do Miocárdio/complicações , Ruptura Cardíaca Pós-Infarto/etiologia , Ruptura Cardíaca Pós-Infarto/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Aneurisma Cardíaco/cirurgia
9.
Medicine (Baltimore) ; 103(19): e38111, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38728493

RESUMO

BACKGROUND: Arteriovenous fistula stenosis can directly lead to the formation of autologous arteriovenous fistula aneurysms (AVFAs), but the coexistence of true and pseudoaneurysms is relatively rare. The coexistence of true and pseudoaneurysms increases the risk of rupture of the arteriovenous fistula and complicates subsequent surgical intervention, potentially posing a threat to the patient's life, and thus requires significant attention. CASE PRESENTATION: The patient presented with arteriovenous fistula (AVF) after hemodialysis 6 years ago. 2 years ago, the patient presented with a mass that had formed near the left forearm arteriovenous fistula and gradually increased in size. Preoperatively, the AVF stenosis was identified as the cause of the mass formation, and the patient was operated on. First, the blood flow was controlled to reduce the pressure at the aneurysm, and then the incision was enlarged to separate the AVF anastomosis from the mass area. The stenotic segment of the true and pseudo aneurysms and cephalic vein was removed and the over-dilated proximal cephalic vein was locally narrowed and subsequently anastomosed with the proximal radial artery to create AVF. The patient was dialyzed with an internal fistula the next day and showed no clinical manifestations related to end-limb ischemia. CONCLUSION: We removed a true pseudoaneurysm in AVF and secured the patient's vascular access. This report provides an effective strategy to manage this condition.


Assuntos
Falso Aneurisma , Derivação Arteriovenosa Cirúrgica , Diálise Renal , Humanos , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Constrição Patológica , Masculino , Pessoa de Meia-Idade , Falência Renal Crônica/terapia , Falência Renal Crônica/complicações , Antebraço/irrigação sanguínea
10.
Medicina (Kaunas) ; 60(5)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38792887

RESUMO

Background and Objectives: Transarterial chemoembolization (TACE) is a widely accepted treatment for hepatocellular carcinoma (HCC). Regarding TACE, arterial injuries, such as hepatic artery spasm or dissection, can also occur, although pseudoaneurysms are rare. We report a case of pseudoaneurysm following TACE. Materials and Methods: A 78-year-old man had been undergoing TACE for HCC in segment 8 of the liver for the past 5 years, with the most recent TACE procedure performed approximately 1 month prior. He presented to the emergency department with melena that persisted for 5 days. Computed tomography revealed a pseudoaneurysm in the S8 hepatic artery with hemobilia. Results: the pseudoaneurysm was successfully treated by N-Butyl-cyanoacrylate glue embolization. Conclusions: In patients that have undergone TACE presenting with melena and hemobilia identified on CT, consideration of hepatic artery pseudoaneurysm is crucial. Such cases can be safely and effectively treated with endovascular managements.


Assuntos
Falso Aneurisma , Carcinoma Hepatocelular , Quimioembolização Terapêutica , Artéria Hepática , Neoplasias Hepáticas , Humanos , Falso Aneurisma/terapia , Falso Aneurisma/etiologia , Masculino , Idoso , Quimioembolização Terapêutica/métodos , Quimioembolização Terapêutica/efeitos adversos , Neoplasias Hepáticas/terapia , Carcinoma Hepatocelular/terapia , Tomografia Computadorizada por Raios X , Procedimentos Endovasculares/métodos , Embolização Terapêutica/métodos , Resultado do Tratamento , Hemobilia/etiologia , Hemobilia/terapia
11.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38792897

RESUMO

The occurrence of the pseudoaneurysm of visceral arteries in the field of chronic pancreatitis is a very rare complication that represents a life-threatening condition. The higher frequency of this complication is in the necrotic form of pancreatic inflammation, especially in patients with formed peripancreatic necrotic collections. The degradation of the arterial wall leads to bleeding and transforms these necrotic collections into a pseudoaneurysm. Urgent endovascular angioembolization is the first choice in the therapeutic approach as a valid minimally invasive solution with very satisfactory immediate and long-term outcomes. This successfully avoids open surgery, which is associated with a high mortality rate in these patients, especially in acute-on-chronic pancreatitis.


Assuntos
Falso Aneurisma , Pancreatite Crônica , Humanos , Falso Aneurisma/terapia , Falso Aneurisma/etiologia , Pancreatite Crônica/complicações , Pancreatite Crônica/terapia , Masculino , Diagnóstico Precoce , Embolização Terapêutica/métodos , Pessoa de Meia-Idade , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
12.
World J Urol ; 42(1): 280, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693433

RESUMO

OBJECTIVE: To perform a comprehensive narrative review that will examine the risk factors and treatment outcomes of arterial pseudoaneurysm following laser flexible ureteroscopy (F-URS). METHODS: A retrospective case series and a review of literature was performed. Clinical records from three patients treated for postoperative arterial pseudoaneurysm from January of 2021 to November 2023 were identified. A comprehensive literature review was also performed. The MEDLINE and Scopus databases were searched. The analysis was made by a narrative synthesis. RESULTS: Three cases of postoperative arterial pseudoaneurysm were included, one from our center, one from Dubai, UAE, and one from Barcelona. The literature review identified six case reports, two after endocorporeal laser lithotripsy with thulium fiber laser (TFL) and four with Ho:YAG laser. All cases, from our series and literature review, presented with macroscopic hematuria and used high-power laser settings. All cases were treated by selective embolization. CONCLUSION: Ho:YAG or TFL lasers are both capable of causing arterial pseudoaneurysms following F-URS if high-power settings are used. Selective artery embolization continues to be the treatment of choice with good outcomes.


Assuntos
Falso Aneurisma , Litotripsia a Laser , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Litotripsia a Laser/efeitos adversos , Litotripsia a Laser/métodos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Ureteroscopia/efeitos adversos , Adulto
13.
Kyobu Geka ; 77(5): 364-368, 2024 May.
Artigo em Japonês | MEDLINE | ID: mdl-38720606

RESUMO

A 59-year-old man was admitted to our hospital with left hemiplegia. A computed tomography( CT) scan and echocardiography revealed a cerebral infarction in the right middle cerebral artery's territory, as well as a large pseudoaneurysm (4×3 cm) of the lateral left ventricular wall. The patient agreed to undergo cardiac surgery because of the high risk of rupture and recurrent cerebral infarctions. Owing to the high probability of damaging the posterior papillary muscle and coronary arteries, an extracardiac approach was used, and the pseudoaneurysm cavity was closed using double-patch repair. The patient was discharged from the hospital on the 12th postoperative day without any complications. Both postoperative CT and echocardiography showed closure of the cavity.


Assuntos
Falso Aneurisma , Infarto Cerebral , Ventrículos do Coração , Humanos , Masculino , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Falso Aneurisma/etiologia , Pessoa de Meia-Idade , Infarto Cerebral/etiologia , Infarto Cerebral/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/cirurgia , Aneurisma Cardíaco/etiologia
14.
J Ultrasound ; 27(2): 393-396, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38632171

RESUMO

One of the principles of managing trauma patients is that of their continuous re-evaluation over the hours and days. Even if the execution of the computed tomography method is classically recommended, especially in the most serious cases and in polytraumas with major dynamics, the clinician can use or request an ultrasound examination, especially in subsequent re-evaluations. Here we report a clinical case demonstrating how an ultrasound re-evaluation after the acute event can lead to a correct diagnosis of a rare complication of thoracic trauma. The findings were suggestive for a pseudoaneurysm of the internal right mammary artery. Subsequently, an ultrasound-guided injection of thrombin was carried out until complete interruption of the flow within the formation. At subsequent follow-up, no arterial or venous blush was highlighted.


Assuntos
Falso Aneurisma , Artéria Torácica Interna , Humanos , Falso Aneurisma/diagnóstico por imagem , Artéria Torácica Interna/diagnóstico por imagem , Masculino , Ultrassonografia/métodos , Adulto , Traumatismos Torácicos/diagnóstico por imagem , Traumatismos Torácicos/complicações
15.
Clin Infect Dis ; 78(6): e69-e80, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38656065

RESUMO

Vascular graft infection (VGI) is one of the most serious complications following arterial reconstructive surgery. VGI has received increasing attention over the past decade, but many questions remain regarding its diagnosis and management. In this review, we describe our approach to VGI through multidisciplinary collaboration and discuss decision making for challenging presentations. This review will concentrate on VGI that impacts both aneurysms and pseudoaneurysms excluding the ascending thoracic aorta.


Assuntos
Procedimentos de Cirurgia Plástica , Infecções Relacionadas à Prótese , Humanos , Procedimentos de Cirurgia Plástica/métodos , Procedimentos de Cirurgia Plástica/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Prótese Vascular/efeitos adversos , Equipe de Assistência ao Paciente , Falso Aneurisma/cirurgia , Falso Aneurisma/etiologia , Artérias/cirurgia
16.
J Craniofac Surg ; 35(4): 1258-1260, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38687036

RESUMO

OBJECTIVE: Report on a case of pseudoaneurysm which was caused by injury of the internal carotid artery (ICA) during endoscopic endonasal surgery (EES), which was followed by rebleeding after treatment with a Willis covered stent. METHODS: A woman, aged 68, underwent EES for the treatment of a pituitary adenoma. During the surgery, the right ICA was injured, and successfully hemostasis by packed with cottonoid and gelatin sponge. Besides, cerebral angiography was performed in the interventional operating room for the purpose of discovering the formation of a pseudoaneurysm in the cavernous sinus segment of ICA, which was treated with a covered stent. After successfully placing the covered stent, the patient was promptly transferred to the general operating room for the removal of the cottonoid and to address the bleeding once again. The authors employ crushed muscles and cottonoid to locally compress and stop bleeding. Owing to concerns about the risk of rebleeding in the patient, after stent implantation, the patient did not utilize antiplatelet drugs. After the surgery, the patient developed occlusion of the right ICA and massive cerebral infarction in the right hemisphere. Dehydration, anti-infection, rehabilitation, hyperbaric oxygen, as well as related treatments, were given. The cottonoid was removed in EES 2 months postsurgery, and no instances of bleeding were observed. Six months after surgery, the patient had clear consciousness and hemiplegia in the left limb, with a Glasgow Outcome Scale score of 4. RESULTS: The ICA was injured during EES, which resulted in the formation of a pseudoaneurysm, the Willis stent was adopted for treatment, and there was a risk of rebleeding after the nasal packing (cottonoid, crushed muscles) was removed immediately. CONCLUSIONS: The ICA was injured during EES after bleeding was controlled by packing with cottonoid, crushed muscles, etc, subsequently, the patient was given intravascular treatment, it is advised to make thorough preparations and, after a suitable period, remove nasal packing in the hybrid operating room to address unexpected situations and unforeseen circumstances.


Assuntos
Lesões das Artérias Carótidas , Artéria Carótida Interna , Neoplasias Hipofisárias , Stents , Humanos , Feminino , Lesões das Artérias Carótidas/etiologia , Lesões das Artérias Carótidas/cirurgia , Lesões das Artérias Carótidas/terapia , Neoplasias Hipofisárias/cirurgia , Idoso , Artéria Carótida Interna/cirurgia , Adenoma/cirurgia , Endoscopia/métodos , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Falso Aneurisma/terapia , Falso Aneurisma/diagnóstico por imagem , Angiografia Cerebral , Recidiva , Complicações Intraoperatórias/etiologia
17.
Digit J Ophthalmol ; 30(1): 19-21, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38601898

RESUMO

Pseudoaneurysm of the internal carotid artery caused by skull base osteomyelitis (SBO) is a lethal condition seen in immunocompromised patients, predominantly those with diabetes mellitus. Cranial nerve involvement is a common complication and generally indicates a poor prognosis. We report the case of a 62-year-old diabetic patient who presented with isolated sixth cranial nerve palsy. She had uncontrolled blood sugar levels and high erythrocyte sedimentation rate, and she suffered from pyelonephritis. Neuroimaging detected SBO with multiple secondary mycotic pseudoaneurysms prominent at the petrocavernous junction. Ischemia is the most common etiology for an isolated abducens nerve palsy, but in certain cases neuroimaging is warranted to prevent life-threatening complications. This case highlights the importance and urgency of identifying and managing such conditions.


Assuntos
Doenças do Nervo Abducente , Falso Aneurisma , Micoses , Osteomielite , Feminino , Humanos , Pessoa de Meia-Idade , Falso Aneurisma/complicações , Falso Aneurisma/diagnóstico , Doenças do Nervo Abducente/etiologia , Doenças do Nervo Abducente/complicações , Base do Crânio , Osteomielite/complicações , Neuroimagem/efeitos adversos , Micoses/complicações
18.
Am J Case Rep ; 25: e942746, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38566390

RESUMO

BACKGROUND RARP is an established procedure in treatment of localized prostate cancer. Hemorrhagic complications in the postoperative period are rare, but sometimes life-threatening. Adequate monitoring and prompt intervention in these unusual scenarios rely on clinical judgement and blood and imaging studies. Prostatic fossa pseudoaneurysm formation after RARP is very rare and its etiology is not well known; it may be related to small vessel trauma. It becomes apparent with the development of hematuria 1-6 weeks after surgery. CASE REPORT A 58-year-old man underwent RARP with extended lymph node dissection for intermediate-risk prostate cancer, with bilateral preservation of neurovascular bundles and puboprostatic ligaments. He was discharged on day 2 without complications. In the following 4 weeks he came to the Emergency Department 3 times with hematuria and acute urinary retention. Four weeks after surgery, a pelvic CT angiogram showed a 20-mm pseudoaneurysm in the prostatic fossa, which was embolized by percutaneous angiography, with resolution of symptoms. He was discharged soon thereafter. CONCLUSIONS This case study describes a patient with prostatic fossa pseudoaneurysm after RARP. It was diagnosed 1 month after surgery and effectively managed by percutaneous embolization. Despite being a very rare condition, it must be kept in mind, especially when postoperative hematuria develops 1-6 weeks after surgery. Use of a management algorithm including serial blood tests, CT angiogram, and percutaneous angiography can lead to early detection and avoid life-threatening hemorrhage and overall postoperative morbidity.


Assuntos
Falso Aneurisma , Neoplasias da Próstata , Robótica , Masculino , Humanos , Pessoa de Meia-Idade , Hematúria/etiologia , Hematúria/cirurgia , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Prostatectomia/efeitos adversos , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Resultado do Tratamento
19.
J Cardiothorac Surg ; 19(1): 212, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38616278

RESUMO

BACKGROUND: A ruptured thoracoabdominal aortic aneurysm (rTAAA) represents a considerable challenge for surgeons. To date, endovascular procedures have not been able to completely replace open repair when debranching is required. CASE PRESENTATION: A 73-year-old man was admitted to our hospital after complaining of left lateral abdominal pain. Enhanced computed tomography revealed a left retroperitoneal hematoma and a large, ruptured Crawford type IV TAAA. We first performed emergency resuscitative surgery to close the lacerated foramen. A graft replacement was performed 1 month after the initial surgery when the patient had stabilized. At 5 years postoperatively, neither occlusion nor anastomotic pseudoaneurysm was noted on computed tomography. CONCLUSIONS: We provide an update on the perioperative management of patients undergoing open rTAAA repair. This procedure can be considered to ensure complete repair of an rTAAA.


Assuntos
Falso Aneurisma , Aneurisma da Aorta Toracoabdominal , Ruptura Aórtica , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Anastomose Cirúrgica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...