Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.937
Filtrar
1.
J Opt Soc Am A Opt Image Sci Vis ; 41(6): 1128-1139, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38856427

RESUMO

Photoacoustic (PA) spectroscopy is considered to be one of the most effective ways to measure the levels of hematocrit (H) and oxygenation saturation (S O 2) of blood, which are essential for diagnosing blood-related illnesses. This simulation study aims to investigate the impact of individual optical parameters, i.e., optical absorption coefficient (µ a), scattering coefficient (µ s), and anisotropy factor (g), on the accuracy of this technique in estimating the blood properties. We first performed the Monte Carlo simulations, using realistic optical parameters, to obtain the fluence maps for various samples. The wavelengths of the incident light were chosen to be 532, 700, 1000, and 1064 nm. Thereafter, the k-Wave simulations were executed, incorporating those fluence maps to generate the PA signals. The blood properties were obtained using the PA signals. We introduced variations in µ a, µ s, and g ranging from -10% to +10%, -10% to +10%, and -5% to +1%, respectively, at 700 and 1000 nm wavelengths. One parameter, at both wavelengths, was changed at a time, keeping others fixed. Subsequently, we examined how accurately the blood parameters could be determined at physiological hematocrit levels. A 10% variation in µ a induces a 10% change in H estimation but no change in S O 2 determination. Almost no change has been seen for µ s variation. However, a 5% (-5% to 0%) variation in the g factor resulted in approximately 160% and 115% changes in the PA signal amplitudes at 700 and 1000 nm, respectively, leading to ≈125% error in hematocrit estimation and ≈14% deviation in S O 2 assessment when nominal S O 2=70%. It is clear from this study that the scattering anisotropy factor is a very sensitive parameter and a small change in its value can result in large errors in the PA estimation of blood properties. In the future, in vitro experiments with pathological blood (inducing variation in the g parameter) will be performed, and accordingly, the accuracy of the PA technique in quantifying blood H and S O 2 will be evaluated.


Assuntos
Método de Monte Carlo , Saturação de Oxigênio , Técnicas Fotoacústicas , Hematócrito , Técnicas Fotoacústicas/métodos , Humanos , Oxigênio/metabolismo , Oxigênio/sangue , Fenômenos Ópticos
2.
Proc Jpn Acad Ser B Phys Biol Sci ; 100(6): 320-334, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38866479

RESUMO

Carbon nanotubes are a telecom band emitter compatible with silicon photonics, and when coupled to microcavities, they present opportunities for exploiting quantum electrodynamical effects. Microdisk resonators demonstrate the feasibility of integration into the silicon platform. Efficient coupling is achieved using photonic crystal air-mode nanobeam cavities. The molecular screening effect on nanotube emission allows for spectral tuning of the coupling. The Purcell effect of the coupled cavity-exciton system reveals near-unity radiative quantum efficiencies of the excitons in carbon nanotubes.


Assuntos
Nanotubos de Carbono , Silício , Nanotubos de Carbono/química , Silício/química , Ar , Fenômenos Ópticos
3.
J Mech Behav Biomed Mater ; 155: 106580, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38759588

RESUMO

OBJECTIVES: To investigate the influence of the zirconia and sintering parameters on the optical and mechanical properties. METHODS: Three zirconia materials (3/4Y-TZP, 4Y-TZP, 3Y-TZP) were high-speed (HSS), speed (SS) or conventionally (CS) sintered. Disc-shaped specimens nested in 4 vertical layers of the blank were examined for grain size (GS), crystal phases (c/t'/t/m-phase), translucency (T), and biaxial flexural strength. Fracture load (FL) of three-unit fixed dental prostheses was determined initially and after thermomechanical aging. Fracture types were classified, and data statistically analyzed. RESULTS: 4Y-TZP showed a higher amount of c + t'-phase and lower amount of t-phase, and higher optical and lower mechanical properties than 3Y-TZP. In all materials, T declined from Layer 1 to 4. 3/4Y-TZP showed the highest FL, followed by 3Y-TZP, while 4Y-TZP showed the lowest. In 4Y-TZP, the sintering parameters exercised a direct impact on GS and T, while mechanical properties were largely unaffected. The sintering parameters showed a varying influence on 3Y-TZP. Thermomechanical aging resulted in comparable or higher FL. CONCLUSION: 3/4Y-TZP presenting the highest FL underscores the principle of using strength-gradient multi-layer blanks to profit from high optical properties in the incisal area, while ensuring high mechanical properties in the lower areas subject to tensile forces. With all groups exceeding maximum bite forces, the examined three-unit FDPs showed promising long-term mechanical properties.


Assuntos
Resistência à Flexão , Teste de Materiais , Zircônio , Zircônio/química , Fenômenos Mecânicos , Tamanho da Partícula , Estresse Mecânico , Fenômenos Ópticos
4.
Med Eng Phys ; 128: 104175, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38789219

RESUMO

OBJECTIVE: To record and extract features of fetal cardiac activities with a semi-rigid prototype optically-pumped magnetometers (OPM) sensor array. METHODS: Fetal magnetocardiography (fMCG) data were collected from 15 pregnant women between 28 and 40 weeks gestation. Mothers were lying flat in a customized bed with sensors touching their abdomen from below using a prototype grid. fMCG was extracted to perform standard fetal heart rate variability (FHRV) analysis. RESULTS: fMCG was observed in 13 of the 15 pregnant women. OPM FHRV indicators were in the range of previous SQUID studies. CONCLUSION: Semi-rigid prototype OPM system has the ability to record quality fMCG. fMCG is capable of identifying lethal cardiac rhythm disturbances in the fetus. Our novel application of OPM technology may lower costs and increase maternal comfort, thus expanding fMCG's generalizability.


Assuntos
Magnetocardiografia , Humanos , Magnetocardiografia/instrumentação , Magnetocardiografia/métodos , Feminino , Gravidez , Adulto , Frequência Cardíaca Fetal , Feto/fisiologia , Fenômenos Ópticos , Dispositivos Ópticos
5.
Phys Med Biol ; 69(12)2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38815615

RESUMO

Objective. Time-of-flight (TOF) is an important factor that directly affects the image quality of PET systems, and various attempts have been made to improve the coincidence resolving time (CRT) of PET detectors. For independent readout detectors, the timing is acquired for each silicon photomultiplier (SiPM), so they are less sensitive to diffused scintillation light, resulting in a better CRT. Further improvement can be expected if the light can be focused on a single SiPM. However, existing SiPM arrays have a thin protective cover on the SiPM and the gap between the SiPMs is filled with either air or the protective cover, so the light must diffuse through the cover. In this work, we investigated optical crosstalk in the protective cover to improve the CRT.Approach. We used 3.1 × 3.1 × 20 mm3fast LGSO crystals and 3 mm square 8 × 8 multi pixel photon counter (MPPC) arrays. Pitch of the MPPCs was 3.2 mm and thickness of the protective cover on them was 150µm. To reduce diffusion of scintillation light in the protective cover, the part of the inactive areas on the MPPC array were optically separated using reflective material. Specifically, 50, 100, 150, and 350µm deep grid-shaped slits were made along the inactive area of the MPPCs and they were filled with BaSO4powder as the reflective material.Main results. Coincidence counts were measured with a pair of TOF detectors, and the CRT was shorter with a deeper slit depth. The CRT before improvement was 235 ps, and using the cover having the 350µm deep slits filled with reflective material lowered the CRT to 211 ps.Significance. Up to 10% of the scintillation light was diffused to other MPPCs by the protective cover, and the CRT was degraded by 10% due to optical crosstalk of the cover. The proposed method promises to improve the CRT of the TOF detector.


Assuntos
Tomografia por Emissão de Pósitrons , Tomografia por Emissão de Pósitrons/instrumentação , Fenômenos Ópticos , Contagem de Cintilação/instrumentação , Fatores de Tempo , Fótons
6.
J Dent ; 146: 105031, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38710315

RESUMO

OBJECTIVES: To investigate and compare the chemical and optical stability of four restorative composite materials: two injectable resins, one flowable resin and one compomer. METHODS: Two injectable nano-filled composite resins: G-aenial Universal (GU) and Beautifil Injectable XSL (BI), a flowable composite resin: Filtek Supreme Flowable (FS) and a compomer: Dyract Flow (DF), in A2 shade were tested and compared. Water sorption and solubility were conducted according to ISO4049:2019 standard; ICP-OES and F-ion selective electrode were used to test the elemental release; Degree of conversion (DC) was obtained by using FTIR; water contact angle was obtained by static sessile drop method, and a spectrophotometer was used for optical properties (ΔE⁎, ΔL⁎ and TP). SPSS 28.0 was used for statistical analysis and the significant level was pre-set as α = 0.05. RESULTS: GU performed the best in water sorption and solubility, FS had the lowest elemental release, the best colour stability, and the highest DCIM and DC24-h. DF, the compomer had the lowest, and GU and BI, the injectable composites had the largest water contact angle, respectively. Correlations were found between water sorption and water solubility. CONCLUSIONS: The four composite restorative materials showed different chemical and optical behaviours. Overall, composite resins performed better than compomer, while additional laboratory and in vivo tests are necessary to obtain a more comprehensive comparison between injectable and flowable composite resins. Wsp and Wsl are influenced by many common factors, and the values are highly positively related. CLINICAL SIGNIFICANCE: A comprehensive understanding of materials is crucial before selecting materials for clinical practice. Composite resins rather than compomers are recommended because of their exceptional properties, which make them eligible for a wide range of clinical applications and an elongated lifespan.


Assuntos
Cor , Compômeros , Resinas Compostas , Materiais Dentários , Teste de Materiais , Solubilidade , Água , Resinas Compostas/química , Materiais Dentários/química , Água/química , Compômeros/química , Humanos , Restauração Dentária Permanente/métodos , Espectrofotometria , Espectroscopia de Infravermelho com Transformada de Fourier , Metacrilatos/química , Injeções , Poliuretanos/química , Nanocompostos/química , Propriedades de Superfície , Fenômenos Ópticos , Bis-Fenol A-Glicidil Metacrilato
7.
Talanta ; 275: 126131, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38663064

RESUMO

The development of an ultra-sensitive detection method for carbohydrate antigen 19-9 (CA19-9) is very important for the early diagnosis of pancreatic cancer. In this work, we developed a new strategy to achieve a variety of Au-Ag hybrid nanoparticles from janus to core-satellite which is controlled by the volume of AgNO3 and the concentration of benzimidazolecarboxylic acid (MBIA). With the volume of AgNO3 increased, Au-Ag hybrid nanoparticles changed from janus to core-satellite and the characteristic absorption peak showed two opposite trends. The size and number of Ag islands were determined by the concentration of MBIA. Au-Ag core-satellites nanoparticles with a large number of small-sized Ag have the highest SERS intensity. Then we used them as SERS nanotags and Au-Polystyrene nanospheres modified by captured anti-CA19-9 antibody as solid substrates to realize the ultra-sensitive detection of CA19-9 with a low limit of detection of 1.25 × 10-6 IU/mL and a wide linear range of 1.00 × 10-5 -1.00 × 104 IU/mL. This work not only demonstrates that MBIA and AgNO3 were the key factors in the growth of Au-Ag hybrid nanoparticles from 2D to 3D structure but also supplies an ultra-sensitive detection method for CA19-9 which has a potential practicability in the clinical early diagnoses of pancreatic cancer.


Assuntos
Antígeno CA-19-9 , Ouro , Nanopartículas Metálicas , Prata , Análise Espectral Raman , Ouro/química , Prata/química , Análise Espectral Raman/métodos , Nanopartículas Metálicas/química , Imunoensaio/métodos , Humanos , Antígeno CA-19-9/sangue , Limite de Detecção , Neoplasias Pancreáticas/diagnóstico , Fenômenos Ópticos
8.
J Biophotonics ; 17(6): e202300536, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38616109

RESUMO

Information about tissue oxygen saturation (StO2) and other related important physiological parameters can be extracted from diffuse reflectance spectra measured through non-contact imaging. Three analytical optical reflectance models for homogeneous, semi-infinite, tissue have been proposed (Modified Beer-Lambert, Jacques 1999, Yudovsky 2009) but these have not been directly compared for tissue parameter extraction purposes. We compare these analytical models using Monte Carlo (MC) simulated diffuse reflectance spectra and controlled gelatin-based phantoms with measured diffuse reflectance spectra and known ground truth composition parameters. The Yudovsky model performed best against MC simulations and measured spectra of tissue phantoms in terms of goodness of fit and parameter extraction accuracy followed closely by Jacques' model. In this study, Yudovsky's model appeared most robust; however, our results demonstrated that both Yudovsky and Jacques models are suitable for modeling tissue that can be approximated as a single, homogeneous, semi-infinite slab.


Assuntos
Gelatina , Método de Monte Carlo , Imagens de Fantasmas , Gelatina/química , Modelos Biológicos , Difusão , Fenômenos Ópticos
9.
Med Phys ; 51(6): 4044-4055, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38682574

RESUMO

BACKGROUND: High-resolution brain positron emission tomography (PET) scanner is emerging as a significant and transformative non-invasive neuroimaging tool to advance neuroscience research as well as improve diagnosis and treatment in neurology and psychiatry. Time-of-flight (TOF) and depth-of-interaction (DOI) information provide markedly higher PET imaging performance by increasing image signal-to-noise ratio and mitigating spatial resolution degradation due to parallax error, respectively. PET detector modules that utilize light sharing can inherently carry DOI information from the multiple timestamps that are generated per gamma event. The difference between two timestamps that are triggered by scintillation photons traveling in opposite directions signifies the event's depth-dependent optical photon TOF (oTOF). However, light leak at the crystal-readout interface substantially degrades the resolution of this oTOF-based depth encoding. PURPOSE: We demonstrate the feasibility of oTOF-based depth encoding by mitigating light leak in single-ended-readout Prism-PET detector modules using tapered crystals. Minimizing light leak also improved both energy-based DOI and coincidence timing resolutions. METHODS: The tapered Prism-PET module consists of a 16  × $\times$  16 array of 1.5  × $\times$  1.5  × $\times$  20  mm 3 ${\rm {mm}}^3$ lutetium yttrium oxyorthosillicate (LYSO) crystals, which are tapered down to 1.2  × $\times$  1.2  mm 2 ${\rm {mm}}^2$ at the crystal-readout interface. The LYSO array couples 4-to-1 to an 8  × $\times$  8 array of 3  × $\times$  3  mm 2 ${\rm {mm}}^2$ silicon photomultiplier (SiPM) pixels on the tapered end and to a segmented prismatoid light guide array on the opposite end. Performance of tapered and non-tapered Prism-PET detectors was experimentally characterized and evaluated by measuring flood histogram, energy resolution, energy-, and oTOF-based DOI resolutions, and coincidence timing resolution. Sensitivities of scanners using different Prism-PET detector designs were simulated using Geant4 application for tomographic emission (GATE). RESULTS: For the tapered (non-tapered) Prism-PET module, the measured full width at half maximum (FWHM) energy, timing, energy-based DOI, and oTOF-based DOI resolutions were 8.88 (11.18)%, 243 (286) ps, 2.35 (3.18) mm, and 5.42 (13.87) mm, respectively. The scanner sensitivities using non-tapered and tapered crystals, and 10 rings of detector modules, were simulated to be 30.9 and 29.5 kcps/MBq, respectively. CONCLUSIONS: The tapered Prism-PET module with minimized light leak enabled the first experimental report of oTOF-based depth encoding at the detector module level. It also enabled the utilization of thinner (i.e., 0.1 mm) inter-crystal spacing with barium sulfate as the reflector while also improving energy-based DOI and timing resolutions.


Assuntos
Fótons , Tomografia por Emissão de Pósitrons , Tomografia por Emissão de Pósitrons/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Fenômenos Ópticos
10.
Colloids Surf B Biointerfaces ; 238: 113878, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38565007

RESUMO

Nitrogen-doped carbon dots (NCD) were synthesized using a simple and fast hydrothermal route, employing citric acid and urea as precursors. The resulting NCDs were non-covalently functionalized (conjugated) with aromatic amino acids, namely phenylalanine (Phe) and tryptophan (Trp). Atomic force microscopy revealed that the NCDs exhibit a disk-like morphology with an average diameter of approximately 60 nm and an average height of about 0.5 nm. Following conjugation, the particle height increased to around 3 nm. UV-vis spectroscopy analysis indicated successful conjugation of the amino acids to the NCD nanostructures. Additionally, DFT numerical calculations based on three differently N-doped clusters were performed to elucidate the nature of the non-covalent interactions between NCDs and the corresponding amino acids. Photoluminescent spectra demonstrated a stable and strong fluorescence signal for both hybrids in the UV region. The most significant changes were observed in the case of Trp-conjugation. In contrast to phenylalanine, the non-covalent bonding of tryptophan to NCDs strongly influenced the visible emission (around 500 nm) originating from surface states of the dots.


Assuntos
Aminoácidos Aromáticos , Carbono , Nanoestruturas , Nitrogênio , Carbono/química , Nitrogênio/química , Aminoácidos Aromáticos/química , Nanoestruturas/química , Pontos Quânticos/química , Propriedades de Superfície , Fenilalanina/química , Tamanho da Partícula , Triptofano/química , Microscopia de Força Atômica , Fenômenos Ópticos , Teoria da Densidade Funcional
11.
Biosensors (Basel) ; 13(4)2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37185514

RESUMO

The global need for accurate and efficient cancer cell detection in biomedicine and clinical diagnosis has driven extensive research and technological development in the field. Precision, high-throughput, non-invasive separation, detection, and classification of individual cells are critical requirements for successful technology. Lab-on-a-chip devices offer enormous potential for solving biological and medical problems and have become a priority research area for microanalysis and manipulating cells. This paper reviews recent developments in the detection of cancer cells using the microfluidics-based lab-on-a-chip method, focusing on describing and explaining techniques that use optical phenomena and a plethora of probes for sensing, amplification, and immobilization. The paper describes how optics are applied in each experimental method, highlighting their advantages and disadvantages. The discussion includes a summary of current challenges and prospects for cancer diagnosis.


Assuntos
Técnicas Biossensoriais , Neoplasias , Dispositivos Lab-On-A-Chip , Óptica e Fotônica , Fenômenos Ópticos , Análise Espectral Raman , Técnicas Biossensoriais/métodos , Neoplasias/diagnóstico
12.
Sci Rep ; 13(1): 4494, 2023 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-36934126

RESUMO

Many image processing operations involve the modification of the spatial frequency content of images. Here we demonstrate object-plane spatial frequency filtering utilizing the angular sensitivity of a commercial spectral bandstop filter. This approach to all-optical image processing is shown to generate real-time pseudo-3D images of transparent biological and other samples, such as human cervical cancer cells. This work demonstrates the potential of non-local, non-interferometric approaches to image processing for uses in label-free biological cell imaging and dynamical monitoring.


Assuntos
Processamento de Imagem Assistida por Computador , Fenômenos Ópticos , Humanos , Processamento de Imagem Assistida por Computador/métodos
15.
Biophys Chem ; 292: 106935, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36410107

RESUMO

We developed the new IR super-resolution microscope by using a 4-wave mixing (4-wave), which is a third-order nonlinear optical process, and carried out the IR super-resolution imaging of the cross section of the rachis of an avian feather. We clearly observed strong signals in the entire region of the rachis at the amide I vibration of ß-keratin in both of the XXYY and YYXX polarization combination. These results are different from images detected by using the vibrational sum-frequency generation (VSFG) method. While the VSFG imaging detects molecules only from the interface, the 4-wave method enables us to observe the signal from the bulk area. We concluded that the four repeating units of ß-keratins in the bulk area which are suggested by X-ray diffraction studies are visualized in the 4-wave detected method. We also applied two IR super-resolution microscopies for the barb and discuss the site dependence of the orientation, distribution and concentration of ß-keratin.


Assuntos
beta-Queratinas , Animais , Plumas , Fenômenos Ópticos , Microscopia , Vibração
16.
In. Cárdenas Díaz, Taimi. Óptica y optometría. Principios y aplicación clínica. Volumen 1. La Habana, Editorial Ciencias Médicas, 2023. , ilus, tab.
Monografia em Espanhol | CUMED | ID: cum-79159
17.
In. Cárdenas Díaz, Taimi. Óptica y optometría. Principios y aplicación clínica. Volumen 1. La Habana, Editorial Ciencias Médicas, 2023. , ilus, tab.
Monografia em Espanhol | CUMED | ID: cum-79158
18.
In. Cárdenas Díaz, Taimi. Óptica y optometría. Principios y aplicación clínica. Volumen 1. La Habana, Editorial Ciencias Médicas, 2023. , ilus.
Monografia em Espanhol | CUMED | ID: cum-79157
19.
Science ; 378(6626): 1315-1320, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36548427

RESUMO

Transparency in animals is a complex form of camouflage involving mechanisms that reduce light scattering and absorption throughout the organism. In vertebrates, attaining transparency is difficult because their circulatory system is full of red blood cells (RBCs) that strongly attenuate light. Here, we document how glassfrogs overcome this challenge by concealing these cells from view. Using photoacoustic imaging to track RBCs in vivo, we show that resting glassfrogs increase transparency two- to threefold by removing ~89% of their RBCs from circulation and packing them within their liver. Vertebrate transparency thus requires both see-through tissues and active mechanisms that "clear" respiratory pigments from these tissues. Furthermore, glassfrogs' ability to regulate the location, density, and packing of RBCs without clotting offers insight in metabolic, hemodynamic, and blood-clot research.


Assuntos
Anuros , Mimetismo Biológico , Coagulação Sanguínea , Eritrócitos , Fígado , Animais , Eritrócitos/citologia , Eritrócitos/fisiologia , Hemodinâmica , Fígado/fisiologia , Anuros/anatomia & histologia , Anuros/sangue , Anuros/fisiologia , Mimetismo Biológico/fisiologia , Fenômenos Ópticos , Contagem de Eritrócitos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...