Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46.529
Filtrar
1.
Sci Rep ; 14(1): 12836, 2024 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834660

RESUMO

This study introduces an evaluation methodology tailored for bioreactors, with the aim of assessing the stress experienced by algae due to harmful contaminants released from antifouling (AF) paints. We present an online monitoring system equipped with an ultra-sensitive sensor that conducts non-invasive measurements of algal culture's optical density and physiological stage through chlorophyll fluorescence signals. By coupling the ultra-sensitive sensor with flash-induced chlorophyll fluorescence, we examined the dynamic fluorescence changes in the green microalga Chlamydomonas reinhardtii when exposed to biocides. Over a 24-h observation period, increasing concentrations of biocides led to a decrease in photosynthetic activity. Notably, a substantial reduction in the maximum quantum yield of primary photochemistry (FV/FM) was observed within the first hour of exposure. Subsequently, we detected a partial recovery in FV/FM; however, this recovery remained 50% lower than that of the controls. Integrating the advanced submersible sensor with fluorescence decay kinetics offered a comprehensive perspective on the dynamic alterations in algal cells under the exposure to biocides released from antifouling coatings. The analysis of fluorescence relaxation kinetics revealed a significant shortening of the fast and middle phases,  along with an increase in the duration of the slow phase, for the coating with the highest levels of biocides. Combining automated culturing and measuring methods, this approach has demonstrated its effectiveness as an ultrasensitive and non-invasive tool for monitoring the physiology of photosynthetic cultures. This is particularly valuable in the context of studying microalgae and their early responses to various environmental conditions, as well as the potential to develop an AF system with minimal harm to the environment.


Assuntos
Reatores Biológicos , Chlamydomonas reinhardtii , Chlamydomonas reinhardtii/efeitos dos fármacos , Chlamydomonas reinhardtii/metabolismo , Desinfetantes/farmacologia , Fluorescência , Fotossíntese/efeitos dos fármacos , Clorofila/metabolismo , Poluentes Químicos da Água/análise
2.
Luminescence ; 39(6): e4798, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38825785

RESUMO

Cellular hypoxia is a common pathological process in various diseases. Detecting cellular hypoxia is of great scientific significance for early diagnosis of tumors. The hypoxia fluorescence probe analysis method can efficiently and conveniently evaluate the hypoxia status in tumor cells. These probes are covalently linked by hypoxic recognition groups and organic fluorescent molecules. Currently, the fluorescent molecules used in these probes often exhibit the aggregation-caused quenching effect, which is not conducive to fluorescence imaging in water. Herein, an activatable hypoxia fluorescence probe was constructed by covalently linking aggregation-induced emission luminogens to the hypoxic recognition group azobenzene. It does not emit fluorescence in solution and in solid state under light excitation due to the presence of photosensitive azo bonds. It can be cleaved by intracellular azoreductase into fluorescent amino derivatives with aggregation-induced emission characteristic. As the concentration of oxygen in cells decreases, its fluorescence intensity increases, making it suitable for fluorescence imaging to detect hypoxic environment in live cancer cells. This work broadens the molecular design approach for activatable hypoxia fluorescent probes.


Assuntos
Hipóxia Celular , Corantes Fluorescentes , Imagem Óptica , Corantes Fluorescentes/química , Corantes Fluorescentes/síntese química , Humanos , Estrutura Molecular , Compostos Azo/química , Células HeLa , Fluorescência
3.
Langenbecks Arch Surg ; 409(1): 170, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38822883

RESUMO

PURPOSE: Perioperative decision making for large (> 2 cm) rectal polyps with ambiguous features is complex. The most common intraprocedural assessment is clinician judgement alone while radiological and endoscopic biopsy can provide periprocedural detail. Fluorescence-augmented machine learning (FA-ML) methods may optimise local treatment strategy. METHODS: Surgeons of varying grades, all performing colonoscopies independently, were asked to visually judge endoscopic videos of large benign and early-stage malignant (potentially suitable for local excision) rectal lesions on an interactive video platform (Mindstamp) with results compared with and between final pathology, radiology and a novel FA-ML classifier. Statistical analyses of data used Fleiss Multi-rater Kappa scoring, Spearman Coefficient and Frequency tables. RESULTS: Thirty-two surgeons judged 14 ambiguous polyp videos (7 benign, 7 malignant). In all cancers, initial endoscopic biopsy had yielded false-negative results. Five of each lesion type had had a pre-excision MRI with a 60% false-positive malignancy prediction in benign lesions and a 60% over-staging and 40% equivocal rate in cancers. Average clinical visual cancer judgement accuracy was 49% (with only 'fair' inter-rater agreement), many reporting uncertainty and higher reported decision confidence did not correspond to higher accuracy. This compared to 86% ML accuracy. Size was misjudged visually by a mean of 20% with polyp size underestimated in 4/6 and overestimated in 2/6. Subjective narratives regarding decision-making requested for 7/14 lesions revealed wide rationale variation between participants. CONCLUSION: Current available clinical means of ambiguous rectal lesion assessment is suboptimal with wide inter-observer variation. Fluorescence based AI augmentation may advance this field via objective, explainable ML methods.


Assuntos
Colonoscopia , Neoplasias Retais , Humanos , Neoplasias Retais/patologia , Neoplasias Retais/cirurgia , Neoplasias Retais/diagnóstico por imagem , Pólipos Intestinais/patologia , Pólipos Intestinais/cirurgia , Aprendizado de Máquina , Masculino , Fluorescência , Feminino , Variações Dependentes do Observador
4.
Tech Coloproctol ; 28(1): 64, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844577

RESUMO

BACKGROUND: This study aimed to investigate the safety and feasibility of indocyanine green near-infrared fluorescence (ICG-NIR) fluorescence-guided video-endoscopic inguinal lymphadenectomy (VEIL) for rectal cancer with inguinal lymph node metastasis (ILNM). METHODS: A retrospective analysis was conducted on 11 patients with rectal cancer who underwent ICG-NIR fluorescence-guided VEIL, assessing various parameters such as operation time, intraoperative bleeding, number of harvested lymph nodes, intraoperative and postoperative complications, and follow-up. RESULTS: Regarding surgical procedures for ILNM, unilateral surgery was performed in 7 cases (54.5%) and bilateral surgery in 4 cases (45.5%). Among these 15 ICG-NIR-guided VEIL surgeries in 11 patients, positive fluorescence visualization was achieved in 13 operations (86.7%). The median estimated blood loss was 10 ml, and the median operation time was 90 min. One case (6.7%) required conversion to open surgery. The median duration of the drain tube was 12 days, and the median length of postoperative hospital stay was 20 days. Postoperative complications were observed, including incisional infection in 2 cases (18.2%), lymphatic leakage in 5 cases (45.5%), urinary infection in 1 case (9.1%), and pneumonia in 3 cases (27.3%). Complications such as skin necrosis, lower limb venous thrombosis, lower limb swelling, or impaired movement were observed during the postoperative follow-up period. No cases of primary lesion, groin, or pelvic lymph node recurrence were observed. CONCLUSION: ICG-NIR fluorescence-guided VEIL is a safe and feasible surgical treatment for rectal cancer with ILNM. ICG fluorescence guidance holds promise as a more personalized and precise approach for VEIL in rectal cancer surgery.


Assuntos
Estudos de Viabilidade , Verde de Indocianina , Canal Inguinal , Excisão de Linfonodo , Metástase Linfática , Duração da Cirurgia , Neoplasias Retais , Cirurgia Vídeoassistida , Humanos , Neoplasias Retais/cirurgia , Neoplasias Retais/patologia , Masculino , Excisão de Linfonodo/métodos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Cirurgia Vídeoassistida/métodos , Canal Inguinal/cirurgia , Complicações Pós-Operatórias/etiologia , Adulto , Linfonodos/patologia , Linfonodos/cirurgia , Linfonodos/diagnóstico por imagem , Corantes , Fluorescência
5.
BMC Cancer ; 24(1): 697, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38844894

RESUMO

BACKGROUND: Fluorescence-guided precision cancer surgery may improve survival and minimize patient morbidity. Efficient development of promising interventions is however hindered by a lack of common methodology. This methodology review aimed to synthesize descriptions of technique, governance processes, surgical learning and outcome reporting in studies of fluorescence-guided cancer surgery to provide guidance for the harmonized design of future studies. METHODS: A systematic search of MEDLINE, EMBASE and CENTRAL databases from 2016-2020 identified studies of all designs describing the use of fluorescence in cancer surgery. Dual screening and data extraction was conducted by two independent teams. RESULTS: Of 13,108 screened articles, 426 full text articles were included. The number of publications per year increased from 66 in 2016 to 115 in 2020. Indocyanine green was the most commonly used fluorescence agent (391, 91.8%). The most common reported purpose of fluorescence guided surgery was for lymph node mapping (195, 5%) and non-specific tumour visualization (94, 2%). Reporting about surgical learning and governance processes incomplete. A total of 2,577 verbatim outcomes were identified, with the commonly reported outcome lymph node detection (796, 30%). Measures of recurrence (32, 1.2%), change in operative plan (23, 0.9%), health economics (2, 0.1%), learning curve (2, 0.1%) and quality of life (2, 0.1%) were rarely reported. CONCLUSION: There was evidence of methodological heterogeneity that may hinder efficient evaluation of fluorescence surgery. Harmonization of the design of future studies may streamline innovation.


Assuntos
Neoplasias , Cirurgia Assistida por Computador , Humanos , Neoplasias/cirurgia , Cirurgia Assistida por Computador/métodos , Fluorescência , Verde de Indocianina , Imagem Óptica/métodos
6.
Anal Chim Acta ; 1306: 342586, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692787

RESUMO

BACKGROUND: Early prostatic cancer (PCa) diagnosis significantly improves the chances of successful treatment and enhances patient survival rates. Traditional enzyme cascade-based early cancer detection methods offer efficiency and signal amplification but are limited by cost, complexity, and enzyme dependency, affecting stability and practicality. Meanwhile, sarcosine (Sar) is commonly considered a biomarker for PCa development. It is essential to develop a Sar detection method based on cascade reactions, which should be efficient, low skill requirement, and suitable for on-site testing. RESULTS: To address this, our study introduces the synthesis of organic-inorganic self-assembled nanoflowers to optimize existing detection methods. The Sar oxidase (SOX)-inorganic hybrid nanoflowers (Cu3(PO4)2:Ce@SOX) possess inherent fluorescent properties and excellent peroxidase activity, coupled with efficient enzyme loading. Based on this, we have developed a dual-mode multi-enzyme cascade nanoplatform combining fluorescence and colorimetric methods for the detection of Sar. The encapsulation yield of Cu3(PO4)2:Ce@SOX reaches 84.5 %, exhibiting a remarkable enhancement in catalytic activity by 1.26-1.29 fold compared to free SOX. The present study employing a dual-signal mechanism encompasses 'turn-off' fluorescence signals ranging from 0.5 µM to 60 µM, with a detection limit of 0.226 µM, and 'turn-on' colorimetric signals ranging from 0.18 µM to 60 µM, with a detection limit of 0.120 µM. SIGNIFICANCE: Furthermore, our study developed an intelligent smartphone sensor system utilizing cotton swabs for real-time analysis of Sar without additional instruments. The nano-platform exhibits exceptional repeatability and stability, rendering it well-suited for detecting Sar in authentic human urine samples. This innovation allows for immediate analysis, offering valuable insights for portable and efficient biosensors applicable to Sar and other analytes.


Assuntos
Colorimetria , Oxirredução , Sarcosina , Smartphone , Sarcosina/urina , Sarcosina/análise , Sarcosina/química , Humanos , Nanoestruturas/química , Limite de Detecção , Espectrometria de Fluorescência , Neoplasias da Próstata/diagnóstico , Fluorescência , Técnicas Biossensoriais , Sarcosina Oxidase/química
7.
Luminescence ; 39(5): e4743, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38692854

RESUMO

A unique luminescent lanthanide metal-organic framework (LnMOF)-based fluorescence detection platform was utilized to achieve sensitive detection of vomitoxin (VT) and oxytetracycline hydrochloride (OTC-HCL) without the use of antibodies or biomolecular modifications. The sensor had a fluorescence quenching constant of 9.74 × 106 M-1 and a low detection limit of 0.68 nM for vomitoxin. Notably, this is the first example of a Tb-MOF sensor for fluorescence detection of vomitoxin. We further investigated its response to two mycotoxins, aflatoxin B1 and ochratoxin A, and found that their Stern-Volmer fluorescence quenching constants were lower than those of VT. In addition, the fluorescence sensor realized sensitive detection of OTC-HCL with a detection limit of 0.039 µM. In conclusion, the method has great potential as a sensitive and simple technique to detect VT and OTC-HCL in water.


Assuntos
Estruturas Metalorgânicas , Oxitetraciclina , Térbio , Oxitetraciclina/análise , Oxitetraciclina/química , Térbio/química , Estruturas Metalorgânicas/química , Espectrometria de Fluorescência , Corantes Fluorescentes/química , Limite de Detecção , Água/química , Fluorescência , Poluentes Químicos da Água/análise
8.
Luminescence ; 39(5): e4747, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38716575

RESUMO

Atezolizumab (ATZ) is a human monoclonal antibody, which has been granted multiple approvals from the US Food and Drug Administration (FDA) for the immunotherapy of different types of cancer. This study describes the prototype of a time-resolved fluoroimmunoassay (TRFIA) for the quantitation of ATZ in plasma. The assay involved the non-competitive binding of ATZ to its specific antigen [programmed death-ligand 1 (PD-L1) protein]. The immune complex formed on the inner surface of the assay plate wells was quantified by anti-human secondary antibody labeled with a chelate of europium-ethylenediaminetetraacetic acid. The enhanced fluorescence signal was generated by an enhanced fluorescence solution composed of thenoyltrifluoroacetone, trioctylphosphine oxide, and Triton X-100. The conditions of the TRFIA were refined, and its optimum procedures were established. The assay was validated in accordance with the immunoassay validation guidelines, and all the validation parameters were acceptable. The working range of the assay was 20-1000 pg mL-1, and its limit of quantitation was 20 pg mL-1. The assay was applied to the quantitation of ATZ in plasma samples with satisfactory accuracy and precision. The proposed TRFIA has significant benefits over the existing methodologies for the quantitation of ATZ in clinical settings.


Assuntos
Anticorpos Monoclonais Humanizados , Fluorimunoensaio , Fluorimunoensaio/métodos , Humanos , Anticorpos Monoclonais Humanizados/sangue , Anticorpos Monoclonais Humanizados/química , Anticorpos Monoclonais Humanizados/imunologia , Fluorescência , Fatores de Tempo
9.
BMC Plant Biol ; 24(1): 464, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38802756

RESUMO

Saline-sodic stress can limit the absorption of available zinc in rice, subsequently impacting the normal photosynthesis and carbohydrate metabolism of rice plants. To investigate the impact of exogenous zinc application on photosynthesis and carbohydrate metabolism in rice grown in saline-sodic soil, this study simulated saline-sodic stress conditions using two rice varieties, 'Changbai 9' and 'Tonghe 899', as experimental materials. Rice seedlings at 4 weeks of age underwent various treatments including control (CT), 2 µmol·L-1 zinc treatment alone (Z), 50 mmol·L-1 saline-sodic treatment (S), and 50 mmol·L-1 saline-sodic treatment with 2 µmol·L-1 zinc (Z + S). We utilized JIP-test to analyze the variations in excitation fluorescence and MR820 signal in rice leaves resulting from zinc supplementation under saline-sodic stress, and examined the impact of zinc supplementation on carbohydrate metabolism in both rice leaves and roots under saline-sodic stress. Research shows that zinc increased the chloroplast pigment content, specific energy flow, quantum yield, and performance of active PSII reaction centers (PIABS), as well as the oxidation (VOX) and reduction rate (Vred) of PSI in rice leaves under saline-sodic stress. Additionally, it decreased the relative variable fluorescence (WK and VJ) and quantum energy dissipation yield (φDO) of the rice. Meanwhile, zinc application can reduce the content of soluble sugars and starch in rice leaves and increasing the starch content in the roots. Therefore, the addition of zinc promotes electron and energy transfer in the rice photosystem under saline-sodic stress. It enhances rice carbohydrate metabolism, improving the rice plants' ability to withstand saline-sodic stress and ultimately promoting rice growth and development.


Assuntos
Metabolismo dos Carboidratos , Clorofila , Oryza , Plântula , Zinco , Oryza/metabolismo , Oryza/efeitos dos fármacos , Zinco/metabolismo , Plântula/metabolismo , Plântula/efeitos dos fármacos , Metabolismo dos Carboidratos/efeitos dos fármacos , Clorofila/metabolismo , Fluorescência , Fotossíntese/efeitos dos fármacos , Folhas de Planta/metabolismo , Folhas de Planta/efeitos dos fármacos
10.
Int J Med Robot ; 20(3): e2636, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38757434

RESUMO

BACKGROUND: To assess the feasibility of use of indocyanine green (ICG) in identifying and minimising urinary tract injury during surgical resection of endometriosis through robotic transvaginal natural orifice transluminal endoscopy surgery (RvNOTES). METHODS: We conducted a retrospective case series in two academic tertiary care hospitals. We examined 53 patients who underwent RvNOTES hysterectomy with planned endometriosis resection. RESULTS: The study involved 53 patients undergoing RvNOTES with ICG fluorescence for endometriosis resection. Mean patient age was 37.98 ± 6.65 years. Operative time averaged 181.32 ± 53.94 min, with estimated blood loss at 45.57 ± 33.62 mL. Postoperative stay averaged 0.23 ± 0.47 days. No ICG-related complications occurred. CONCLUSION: No complications occurred with ICG fluorescence in RvNOTES. It appears to be a safe option for ureteral localisation and preservation. ICG fluorescence is widely used in diverse medical specialities for identifying ureters during complex surgeries. Larger studies are needed to firmly establish its advantages in intraoperative ureteral visualisation during RvNOTES for deep infiltrative endometriosis.


Assuntos
Endometriose , Estudos de Viabilidade , Verde de Indocianina , Cirurgia Endoscópica por Orifício Natural , Procedimentos Cirúrgicos Robóticos , Ureter , Humanos , Feminino , Endometriose/cirurgia , Endometriose/diagnóstico por imagem , Procedimentos Cirúrgicos Robóticos/métodos , Adulto , Estudos Retrospectivos , Cirurgia Endoscópica por Orifício Natural/métodos , Ureter/cirurgia , Pessoa de Meia-Idade , Fluorescência , Vagina/cirurgia , Duração da Cirurgia , Histerectomia/métodos
11.
ACS Appl Bio Mater ; 7(5): 3460-3468, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38703374

RESUMO

Trimethylamine N-oxide (TMAO), a molecule produced by the microbiota, has been associated with human health and illness. Its early discovery in body fluids may affect our understanding of the pathophysiology and treatment of many illnesses. Therefore, our knowledge of the pathophysiology and diagnostics of disorders associated with TMAO might be enhanced by the creation of dependable and fast methods for TMAO detection. Therefore, we developed a fluorescent probe for detecting TMAO utilizing an on-off-on strategy. Bovine serum albumin (BSA)@AuNCs luminescence is effectively quenched by Mo4+ because BSA@AuNCs and Mo4+ have a strong binding relationship. Mo4+ ions can substantially decrease the emission intensity of gold nanoclusters by establishing a BSA@AuNCs-Mo system. Then, the luminescence of BSA@AuNCs was restored due to the interaction between Mo4+ and TMAO. A significant linear relationship was seen between the emission intensity and TMAO concentration within the 0-201 µM range, with a detection limit of 1.532 µM. Additionally, the method can measure TMAO in blood and urine samples.


Assuntos
Corantes Fluorescentes , Ouro , Teste de Materiais , Nanopartículas Metálicas , Metilaminas , Tamanho da Partícula , Soroalbumina Bovina , Metilaminas/química , Ouro/química , Soroalbumina Bovina/química , Nanopartículas Metálicas/química , Humanos , Corantes Fluorescentes/química , Materiais Biocompatíveis/química , Bovinos , Animais , Fluorescência , Espectrometria de Fluorescência , Estrutura Molecular
12.
Luminescence ; 39(5): e4778, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38772865

RESUMO

To establish a new method for detecting crystal violet (CV), a harmful dye, herein, a genre of novel biomass carbon dots (CDs) was synthesized via a microwave method and employed as a fluorescent probe, in which water spinach and polyethylene glycol (PEG) performed as raw materials. Based on the inner filter effect (IFE) between the luminescent CDs and CV, the blue emission of this probe at 430 nm could be quenched by CV. Hence, a new strategy was proposed to selectively determine CV in aquaculture ambient. Moreover, under the optimal experiment conditions, this method showed a good linearity between the concentration of CV (c) and fluorescence quenching rate (ΔF/F0) in the concentration range of 4-200 µmol/L with the corresponding correlation coefficient (r) and the detection limit of 0.997 and 710 nmol/L, respectively. With advantages of environmental protectivity, sensitivity, affordability, and user-friendliness, the facilely fabricated CDs could be successfully applied in detecting CV in aquaculture samples, providing a technical foundation for monitoring the pollution of CV and ensuring the quality and safety of aquatic products.


Assuntos
Biomassa , Carbono , Corantes Fluorescentes , Violeta Genciana , Micro-Ondas , Pontos Quânticos , Violeta Genciana/química , Carbono/química , Pontos Quânticos/química , Corantes Fluorescentes/química , Corantes Fluorescentes/síntese química , Espectrometria de Fluorescência , Fluorescência , Polietilenoglicóis/química
13.
Acta Trop ; 255: 107249, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38740319

RESUMO

BACKGROUND: Natural human infections by Plasmodium cynomolgi and P. inui have been reported recently and gain the substantial attention from Southeast Asian countries. Zoonotic transmission of non-human malaria parasites to humans from macaque monkeys occurred through the bites of the infected mosquitoes. The objective of this study is to establish real-time fluorescence loop-mediated isothermal amplification (LAMP) assays for the detection of zoonotic malaria parasites by combining real-time fluorescent technology with the isothermal amplification technique. METHODS: By using 18S rRNA as the target gene, the primers for P. cynomolgi, P. coatneyi and P. inui were newly designed in the present study. Four novel real-time fluorescence LAMP assays were developed for the detection of P. cynomolgi, P. coatneyi, P. inui and P. knowlesi. The entire amplification process was completed in 60 min, with the assays performed at 65 °C. By using SYTO-9 as the nucleic acid intercalating dye, the reaction was monitored via real-time fluorescence signal. RESULTS: There was no observed cross-reactivity among the primers from different species. All 70 field-collected monkey samples were successfully amplified by real-time fluorescence LAMP assays. The detection limit for P. cynomolgi, P. coatneyi and P. knowlesi was 5 × 109 copies/µL. Meanwhile, the detection limit of P. inui was 5 × 1010 copies/µL. CONCLUSION: This is the first report of the detection of four zoonotic malaria parasites by real-time fluorescence LAMP approaches. It is an effective, rapid and simple-to-use technique. This presented platform exhibits considerable potential as an alternative detection for zoonotic malaria parasites.


Assuntos
Malária , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Plasmodium , RNA Ribossômico 18S , Sensibilidade e Especificidade , Zoonoses , Animais , Técnicas de Amplificação de Ácido Nucleico/métodos , Malária/diagnóstico , Malária/parasitologia , Malária/veterinária , RNA Ribossômico 18S/genética , Técnicas de Diagnóstico Molecular/métodos , Plasmodium/genética , Plasmodium/isolamento & purificação , Plasmodium/classificação , Zoonoses/parasitologia , Zoonoses/diagnóstico , Humanos , Primers do DNA/genética , Fluorescência , Macaca/parasitologia , Doenças dos Macacos/parasitologia , Doenças dos Macacos/diagnóstico
14.
Biosensors (Basel) ; 14(5)2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38785694

RESUMO

Detecting low concentrations of biomarkers is essential in clinical laboratories. To improve analytical sensitivity, especially in identifying fluorescently labeled molecules, typical optical detection systems, consisting of a photodetector or camera, utilize time-resolved measurements. Taking a different approach, magnetic modulation biosensing (MMB) is a novel technology that combines fluorescently labeled probes and magnetic particles to create a sandwich assay with the target molecules. By concentrating the target molecules and then using time-resolved measurements, MMB provides the rapid and highly sensitive detection of various biomarkers. Here, we propose a novel signal-processing algorithm that enhances the detection and estimation of target molecules at low concentrations. By incorporating both temporally and spatially resolved measurements using human interleukin-8 as a target molecule, we show that the new algorithm provides a 2-4-fold improvement in the limit of detection and an ~25% gain in quantitative resolution.


Assuntos
Técnicas Biossensoriais , Imunoensaio/métodos , Humanos , Algoritmos , Fluorescência , Interleucina-8/análise , Limite de Detecção , Biomarcadores/análise
15.
Proc Natl Acad Sci U S A ; 121(24): e2318189121, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38814876

RESUMO

Fluorescence, the optical phenomenon whereby short-wavelength light is absorbed and emitted at longer wavelengths, has been widely described in aquatic habitats, in both invertebrates and fish. Recent years have seen a stream of articles reporting fluorescence, ranging from frogs, platypus, to even fully terrestrial organisms such as flying squirrels, often explicitly or implicitly linking the presence of fluorescence with sexual selection and communication. However, many of these studies fail to consider the physiological requirements of evolutionary stable signaling systems, the environmental dependence of perception, or the possible adaptive role of fluorescent coloration in a noncommunicative context. More importantly, the idea that fluorescence may simply constitute an indirect by-product of selection on other traits is often not explored. This is especially true for terrestrial systems where environmental light conditions are often not amenable for fluorescent signaling in contrast to, for example, aquatic habitats in which spectral properties of water promote functional roles for fluorescence. Despite the appeal of previously unknown ways in which coloration may drive evolution, the investigation of a putative role of fluorescence in communication must be tempered by a realistic understanding of its limitations. Here, we not only highlight and discuss the key body of literature but also address the potential pitfalls when reporting fluorescence and how to solve them. In addition, we propose exciting different research avenues to advance the field of tetrapod fluorescence.


Assuntos
Evolução Biológica , Animais , Fluorescência , Vertebrados/fisiologia , Comunicação Animal , Ecossistema
16.
Anal Chim Acta ; 1310: 342716, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811135

RESUMO

BACKGROUND: Assembling framework nucleic acid (FNA) nanoarchitectures and tuning luminescent quantum dots (QDs) for fluorescence assays represent a versatile strategy in analytical territory. Rationally, FNA constructs could offer a preferential orientation to efficiently recognize the target and improve detection sensitivity, meanwhile, regulating size-dependent multicolor emissions of QDs in one analytical setting for ratiometric fluorescence assay would greatly simplify operation procedures. Nonetheless, such FNA/QDs-based ratiometric fluorescence nanoprobes remain rarely explored. RESULTS: We designed a sensitive and signal amplification-free fluorescence aptasensor for lead ions (Pb2+) that potentially cause extensive contamination to environment, cosmetic, food and pharmaceuticals. Red and green emission CdTe quantum dots (rQDs and gQDs) were facilely prepared. Moreover, silica nanosphere encapsulating rQDs served as quantitative internal reference and scaffold to anchor a predesigned FNA and DNA sandwich containing Pb2+ binding aptamer and gQD modified DNA signal reporter. On binding of Pb2+, the gQD-DNA signal reporter was set free, resulting in fluorescence quenching at graphene oxide (GO) interface. Owing to the rigid structure of FNA, the fluorescence signal reporter orderly arranged at the silica nanosphere could sensitively respond to Pb2+ stimulation. The dose-dependent fluorescence signal-off mode enabled ratiometric analysis of Pb2+ without cumbersome signal amplification. Linear relationship was established between fluorescence intensity ratio (I555/I720) and Pb2+ concentration from 10 nM to 2 µM, with detection limit of 1.7 nM (0.43 ppb), well addressing the need for Pb2+ routine monitoring. The designed nanoprobe was applied to detection of Pb2+ in soil, cosmetic, milk, drug, and serum samples, with the sensitivity comparable to conventional ICP-MS technique. SIGNIFICANCE: Given the programmable design of FNA and efficient recognition of target, flexible tuning of QDs emission, and signal amplification-free strategy, the present fluorescence nanoprobe could be a technical criterion for other heavy metal ions detection in a straightforward manner.


Assuntos
DNA , Grafite , Chumbo , Nanosferas , Pontos Quânticos , Dióxido de Silício , Espectrometria de Fluorescência , Pontos Quânticos/química , Chumbo/análise , Chumbo/química , Grafite/química , Dióxido de Silício/química , Nanosferas/química , DNA/química , Compostos de Cádmio/química , Limite de Detecção , Telúrio/química , Aptâmeros de Nucleotídeos/química , Fluorescência , Técnicas Biossensoriais/métodos
17.
Biol Pharm Bull ; 47(5): 1054-1057, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38811191

RESUMO

Glycosaminoglycans (GAGs), such as heparan sulfate (HS), play essential roles in living organisms. Understanding the functionality of HS and its involvement in disease progression necessitates the sensitive and quantitative detection of HS-derived unsaturated disaccharides. Conventionally, fluorescence derivatization precedes the HPLC analysis of these disaccharides. However, the presence of excess unreacted derivatization reagents can inhibit rapid and sensitive analysis in chromatographic determinations. In this study, we describe analytical methods that use dansylhydrazine as a derivatization agent for the detection and determination of HS-derived unsaturated disaccharides using HPLC. In addition, we have developed a straightforward method for removing excess unreacted reagent using a MonoSpin NH2 column. This method may be employed to remove excess pre-labeling reagents, thereby facilitating the analysis of HS-derived unsaturated disaccharides with satisfactory reproducibility.


Assuntos
Compostos de Dansil , Dissacarídeos , Heparitina Sulfato , Cromatografia Líquida de Alta Pressão/métodos , Heparitina Sulfato/química , Heparitina Sulfato/análise , Dissacarídeos/análise , Compostos de Dansil/química , Hidrazinas/química , Espectrometria de Fluorescência/métodos , Fluorescência
18.
Zhongguo Zhong Yao Za Zhi ; 49(7): 1818-1825, 2024 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-38812194

RESUMO

A label-free fluorescence method based on malachite green/aptamer was developed for the detection of ochratoxin A(OTA) in traditional Chinese medicines. Malachite green itself exhibits weak fluorescence. Upon interaction with the aptamer specific to OTA, the G-quadruplex structure of the aptamer provides a protective microenvironment for malachite green, which significantly enhances its fluorescence signal. After OTA is added, preferential binding occurs between the aptamer and OTA, and malachite green will be released from the aptamer, which weakens the fluorescence signal. According to this principle, this paper established a fluorescence method with the aptamer of OTA as the recognition element and malachite green as the fluorescent probe for the detection of OTA in traditional Chinese medicines. The key experimental factors such as the concentrations of metal ions, aptamer, and malachite green were optimized to improve the performance of the method. OTA was detected under the optimal experimental conditions, and the results showed that with the increase in OTA concentration, the fluorescence signal gradually weakened. Within the range of 20-1 000 nmol·L~(-1), the OTA concentration was linearly correlated with the fluorescence signal ratio ΔF/F(ΔF=F_0-F, where F_0 is the fluorescence signal of aptamer/malachite green, and F is the fluorescence signal of OTA/aptamer/malachite green), with R~2 of 0.995. The limit of detection of the established method was 7.1 nmol·L~(-1). Furthermore, three substances structurally similar to OTA and two mycotoxins that may coexist with OTA were selected for experiments, which aimed to examine the cross-reactivity and specificity of the established method. The cross-reactivity experiments demonstrated that the interferers did not significantly affect the fluorescence signal of the detection system. The specificity experiments revealed that when mycotoxins were mixed with OTA, the fluorescence signal generated by the mixture closely resembled that of OTA itself. The results indicated that even in the presence of interferents, the established method remained unaffected and demonstrated excellent specificity. Additionally, this method exhibited remarkable reproducibility and stability. In the case of simple centrifugation and dilution of traditional Chinese medicine samples(Puerariae Lobatae Radix, Sophorae Flavescentis Radix, and Periplocae Cortex), the OTA detection method was applicable, with recovery rates ranging from 91.5% to 121.3%. Notably, this approach does not need complex pretreatment of traditional Chinese medicines while offering simple operation, low detection costs, and short detection time. Furthermore, by incorporating aptamers into the quality evaluation of traditional Chinese medicines, this method expands the application scope of aptamers.


Assuntos
Aptâmeros de Nucleotídeos , Medicamentos de Ervas Chinesas , Ocratoxinas , Corantes de Rosanilina , Corantes de Rosanilina/química , Corantes de Rosanilina/análise , Ocratoxinas/análise , Ocratoxinas/química , Aptâmeros de Nucleotídeos/química , Medicamentos de Ervas Chinesas/química , Medicamentos de Ervas Chinesas/análise , Espectrometria de Fluorescência/métodos , Contaminação de Medicamentos/prevenção & controle , Fluorescência , Medicina Tradicional Chinesa
19.
Environ Sci Technol ; 58(21): 9213-9226, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38748643

RESUMO

The use of optical proxies is essential to the sustained monitoring of dissolved organic carbon (DOC) in estuaries and coastal wetlands, where dynamics occur on subhour time scales. In situ dissolved organic matter (DOM) fluorescence, or FDOM, is now routinely measured along with ancillary water-quality indicators by commercial sondes. However, its reliability as an optical proxy of DOC concentration is often limited by uncertainties caused by in situ interferences and by variability in DOM composition and water matrix (ionic strength, pH) that are typical at the land-ocean interface. Although corrections for in situ interferences already exist, validated strategies to account for changes in the DOM composition and water matrix in these systems are still lacking. The transferability of methods across systems is also poorly known. Here, we used a comprehensive data set of laboratory-based excitation-emission matrix fluorescence and DOC concentration matched to in situ sonde measurements to develop and compare approaches that leverage ancillary water-quality indicators to improve estimates of DOC concentration from FDOM. Our analyses demonstrated the validity of in situ interference correction schemes, the importance of ancillary water-quality indicators to account for DOM composition and water matrix change, and the good transferability of the proposed methods.


Assuntos
Carbono , Monitoramento Ambiental , Estuários , Áreas Alagadas , Monitoramento Ambiental/métodos , Fluorescência
20.
Int J Mol Sci ; 25(10)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38791347

RESUMO

IR-783, a commercially available near-infrared (NIR) heptamethine cyanine dye, has been used for selective tumor imaging in breast, prostate, cervical, and brain cancers in vitro and in vivo. Although the molecular mechanism behind the structure-inherent tumor targeting of IR-783 has not been well-demonstrated, IR-783 has unique properties such as a good water solubility and low cytotoxicity compared with other commercial heptamethine cyanine dyes. The goal of this study is to evaluate the phototherapeutic efficacy of IR-783 as a tumor-targeted photothermal agent in human colorectal cancer xenografts. The results demonstrate that IR-783 shows both the subcellular localization in HT-29 cancer cells and preferential accumulation in HT-29 xenografted tumors 24 h after its intravenous administration. Furthermore, the IR-783 dye reveals the superior capability to convert NIR light into heat energy under 808 nm NIR laser irradiation in vitro and in vivo, thereby inducing cancer cell death. Taken together, these findings suggest that water-soluble anionic IR-783 can be used as a bifunctional phototherapeutic agent for the targeted imaging and photothermal therapy (PTT) of colorectal cancer. Therefore, this work provides a simple and effective approach to develop biocompatible, hydrophilic, and tumor-targetable PTT agents for targeted cancer phototherapy.


Assuntos
Terapia Fototérmica , Humanos , Terapia Fototérmica/métodos , Animais , Camundongos , Ensaios Antitumorais Modelo de Xenoenxerto , Células HT29 , Carbocianinas/química , Camundongos Nus , Raios Infravermelhos , Neoplasias Colorretais/terapia , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/tratamento farmacológico , Corantes Fluorescentes/química , Fluorescência , Camundongos Endogâmicos BALB C
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...