Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.364
Filtrar
1.
Sci Rep ; 14(1): 12604, 2024 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824230

RESUMO

Pulse wave encephalopathy (PWE) is hypothesised to initiate many forms of dementia, motivating its identification and risk assessment. As candidate pulsatility based biomarkers for PWE, pulsatility index and pulsatility damping have been studied and, currently, do not adequately stratify risk due to variability in pulsatility and spatial bias. Here, we propose a locus-independent pulsatility transmission coefficient computed by spatially tracking pulsatility along vessels to characterise the brain pulse dynamics at a whole-organ level. Our preliminary analyses in a cohort of 20 subjects indicate that this measurement agrees with clinical observations relating blood pulsatility with age, heart rate, and sex, making it a suitable candidate to study the risk of PWE. We identified transmission differences between vascular regions perfused by the basilar and internal carotid arteries attributed to the identified dependence on cerebral blood flow, and some participants presented differences between the internal carotid perfused regions that were not related to flow or pulsatility burden, suggesting underlying mechanical differences. Large populational studies would benefit from retrospective pulsatility transmission analyses, providing a new comprehensive arterial description of the hemodynamic state in the brain. We provide a publicly available implementation of our tools to derive this coefficient, built into pre-existing open-source software.


Assuntos
Circulação Cerebrovascular , Imageamento por Ressonância Magnética , Fluxo Pulsátil , Humanos , Feminino , Masculino , Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos , Idoso , Pessoa de Meia-Idade , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Encéfalo/irrigação sanguínea , Análise de Onda de Pulso/métodos , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/fisiologia , Artéria Basilar/diagnóstico por imagem , Artéria Basilar/fisiologia , Adulto
2.
Brain Behav ; 14(5): e3526, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38783554

RESUMO

OBJECTIVE: This study investigated the correlation between the pulsatility index (PI) of the middle cerebral artery with the total burden of cerebral small vessel disease and cognitive impairment. METHOD: Information on patients hospitalized in the Department of Neurology was collected retrospectively. These patients had complete clinical and laboratory data. The middle cerebral artery PI was measured using transcranial Doppler, a Mini-Mental State Examination (MMSE) was used to assess cognitive function, and the total cerebral small vessel disease burden was assessed using magnetic resonance imaging. Patients were grouped according to their scores for total imaging burden of cerebral small vessel disease and cognitive function. Logistic regression analysis assessed the association between the PI, total imaging burden, and cognitive impairment. Spearman analysis was used to evaluate the correlation between the PI and total imaging burden and cognitive impairment, and receiver operating characteristic (ROC) curves were used to determine the predictive value of the PI for cognitive function. RESULTS: The PI was higher in the cognitive impairment (CI) group than in the no-CI group. Binary logistic regression analysis showed that increased PI was an independent risk factor for CI (OR = 1.582; 95% CI: 1.043-2.401; p = .031) and total imaging burden (OR = 1.842; 95% CI: 1.274-2.663; p = .001). Spearman analysis found that the PI correlated negatively with the MMSE score (r = -.627, p < .001). ROC curve analysis showed the PI predicted CI with an area under the curve of 0.784. The PI combined with the total imaging burden predicted CI in cerebral small vessel disease with an area under the curve of 0.832. CONCLUSION: An increased PI was associated with CI and a high imaging burden in cerebral small vessel disease patients. The PI combined with the total burden score shows a high predictive value for CI.


Assuntos
Doenças de Pequenos Vasos Cerebrais , Disfunção Cognitiva , Imageamento por Ressonância Magnética , Artéria Cerebral Média , Fluxo Pulsátil , Ultrassonografia Doppler Transcraniana , Humanos , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Doenças de Pequenos Vasos Cerebrais/fisiopatologia , Masculino , Feminino , Disfunção Cognitiva/fisiopatologia , Disfunção Cognitiva/diagnóstico por imagem , Disfunção Cognitiva/etiologia , Idoso , Pessoa de Meia-Idade , Estudos Retrospectivos , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/fisiopatologia , Fluxo Pulsátil/fisiologia , Testes de Estado Mental e Demência
3.
Front Endocrinol (Lausanne) ; 15: 1278504, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38686203

RESUMO

Objective: The objective was to analyze the impact of the uterine artery pulsatility index (PI) on pregnancy outcomes by measuring uterine artery blood flow on the day of endometrial transformation in patients undergoing frozen-thawed embryo transfer (FET). Methods: This was a case-control study. In total, 2,036 patients who underwent FET at the Third Affiliated Hospital of Zhengzhou University from October 2019 to September 2020 were included. The patients were divided into a clinical pregnancy group and a nonclinical pregnancy group according to pregnancy outcome. A multivariate logistic regression model was used to analyze the factors affecting the clinical pregnancy rate. The receiver operating characteristic (ROC) curve was used to determine the optimal mean PI cutoff value of 1.75. After 1:1 propensity score matching (PSM), 562 patients were included. For statistical description and analysis, the patients were divided into two groups: a group with a mean PI > 1.75 and a group with a mean PI ≤ 1.75. Results: The clinical pregnancy group included 1,218 cycles, and the nonclinical pregnancy group included 818 cycles. There were significant differences in female age (P<0.01), infertility type (P=0.04), baseline follicle-stimulating hormone level (P=0.04), anti-Müllerian hormone (AMH) level (P<0.01), antral follicle count (P<0.01), number of transferred embryos (P=0.045) and type of transferred embryo (P<0.01). There was no significant difference in the mean bilateral PI (1.98 ± 0.34 vs. 1.95 ± 0.35, P=0.10). The multivariate analysis results showed that maternal age (AOR=0.95, 95% CI=0.93-0.98, P<0.01), AMH level (AOR=1.00, 95% CI=1.00-1.01, P=0.045), number of transferred embryos (AOR=1.98, 95% CI=1.47-2.70, P<0.01), and type of transferred embryo (AOR=3.10, 95% CI=2.27-4.23, P<0.01) were independent factors influencing the clinical pregnancy rate. The mean PI (AOR=0.85, 95% CI=0.70-1.05; P=0.13) was not an independent factor influencing the clinical pregnancy rate. Participants were divided into two groups according to the mean PI cutoff value of 1.75, and there was no significant difference between the two groups (P > 0.05). Conclusion: In this study, we found that the uterine artery PI on the day of endometrial transformation in patients undergoing FET is not a good predictor of pregnancy outcomes.


Assuntos
Criopreservação , Transferência Embrionária , Endométrio , Resultado da Gravidez , Taxa de Gravidez , Fluxo Pulsátil , Artéria Uterina , Humanos , Feminino , Gravidez , Transferência Embrionária/métodos , Adulto , Artéria Uterina/diagnóstico por imagem , Artéria Uterina/fisiologia , Estudos de Casos e Controles , Fluxo Pulsátil/fisiologia , Endométrio/irrigação sanguínea , Endométrio/diagnóstico por imagem , Fertilização in vitro/métodos , Estudos Retrospectivos
4.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(2): 351-359, 2024 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-38686417

RESUMO

In this work, we investigated the influence of the bifurcation geometry of the iliac artery on the propagation properties of the pulse wave, and applied software to establish the straight bifurcation and curved bifurcation bi-directional fluid-solid coupling finite element analysis models based on the iliac artery, and compared and analyzed the influence of the bifurcation angle of the blood vessel on the propagation characteristics of the pulse wave. It was found that the bifurcation geometry had a significant effect on the pulse wave propagation in the iliac arteries, and the pressure and velocity pulse wave amplitudes predicted by these two models had a good agreement with that before the vessel bifurcation in a cardiac cycle. The curvilinear bifurcation model predicted the pulse wave amplitude to be lower and the pressure drop to be smaller after the bifurcation, which was more in line with the actual situation of the human body. In addition, the bifurcation point is accompanied by the stress concentration phenomenon in the vessel wall, and there is a transient increase in the velocity pulse waveform amplitude, which was consistent with the fact that the bifurcation site is prone to phenomena such as arterial stenosis and hardening. The preliminary results of this paper will provide some reference for the use of pulse waveforms in the diagnosis of arterial diseases.


Assuntos
Análise de Elementos Finitos , Artéria Ilíaca , Modelos Cardiovasculares , Análise de Onda de Pulso , Humanos , Artéria Ilíaca/fisiologia , Pressão Sanguínea/fisiologia , Fluxo Pulsátil/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Simulação por Computador
5.
J Biomech Eng ; 146(10)2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38683061

RESUMO

Computational fluid dynamics (CFD) simulations are widely used to develop and analyze blood-contacting medical devices such as left ventricular assist devices (LVADs). This work presents an analysis of the transient behavior of two centrifugal LVADs with different designs: HeartWare VAD and HeartMate3. A scale-resolving methodology is followed through Large Eddy Simulations, which allows for the visualization of turbulent structures. The three-dimensional (3D) LVAD models are coupled to a zero-dimensional (0D) 2-element Windkessel model, which accounts for the vascular resistance and compliance of the arterial system downstream of the device. Furthermore, both continuous- and pulsatile-flow operation modes are analyzed. For the pulsatile conditions, the artificial pulse of HeartMate3 is imposed, leading to a larger variation of performance variables in HeartWare VAD than in HeartMate3. Moreover, CFD results of pulsatile-flow simulations are compared to those obtained by accessing the quasi-steady maps of the pumps. The quasi-steady approach is a predictive tool used to provide a preliminary approximation of the pulsatile evolution of flow rate, pressure head, and power, by only imposing a speed pulse and vascular parameters. This preliminary quasi-steady solution can be useful for deciding the characteristics of the pulsatile speed law before running a transient CFD simulation, as the former entails a significant reduction in computational cost in comparison to the latter.


Assuntos
Coração Auxiliar , Hidrodinâmica , Fluxo Pulsátil , Modelos Cardiovasculares , Simulação por Computador , Centrifugação , Humanos
6.
J Exp Biol ; 227(20)2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38644758

RESUMO

In bivalves and gastropods, ventricle contraction causes a negative pressure in the auricles and increases venous return from the afferent oblique vein (AOV): the constant-volume (CV) mechanism. The flow in the AOV should be a pulsative flow synchronized with the ventricular contraction. The flow in the heart and adjacent vessels of Mytilus galloprovincialis were measured by magnetic resonance imaging to confirm this hypothesis. Under a regular heartbeat, pulsative flows in the AOV and branchial vessels (BVs) were almost completely synchronized with the flow in the aorta, while filling of the ventricle was in the opposite phase. Flows in the BVs were directed to the posterior direction, and a pair of BVs in the gill axes (the efferent BVs) were connected to the AOV. Based on the images of the whole pathway of the AOV in an oblique slice, we confirmed that haemolymph flow was evoked from the efferent BVs and flow into the ventricle via the auricle was completed in a single heartbeat. Therefore, the walls of the AOV and BVs could resist negative transmural pressure caused by the ventricular contraction. In conclusion, the auricle, the AOV and the BVs, including the gill filaments, act as a suction pump. The pulsative venous return is driven by the negative pressure of the AOV as in the CV mechanism, and the negative pressure in the efferent BVs could draw haemolymph from the sinus via the gill and the afferent BVs. Therefore, Mytilus can start and stop its heartbeat as necessary.


Assuntos
Mytilus , Animais , Mytilus/fisiologia , Coração/fisiologia , Veias/fisiologia , Brânquias/fisiologia , Imageamento por Ressonância Magnética , Região Branquial/fisiologia , Hemolinfa/fisiologia , Fluxo Pulsátil/fisiologia
7.
J Appl Physiol (1985) ; 136(6): 1376-1387, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38601998

RESUMO

Mechanisms behind the protective effects of aerobic exercise on brain health remain elusive but may be vascular in origin and relate to cerebral pulsatility. This pilot study investigated the effects of 12-wk aerobic exercise training on cerebral pulsatility and its vascular contributors (large artery stiffness, characteristic impedance) in at-risk middle-aged adults. Twenty-eight inactive middle-aged adults with elevated blood pressure or stage 1 hypertension were assigned to either moderate/vigorous aerobic exercise training (AET) for 3 days/wk or no-exercise control (CON) group. Middle cerebral artery (MCA) pulsatility index (PI), large artery (i.e., aorta, carotid) stiffness, and characteristic impedance were assessed via Doppler and tonometry at baseline, 6, and 12 wk, whereas cardiorespiratory fitness (V̇o2peak) was assessed via incremental exercise test and cognitive function via computerized battery at baseline and 12 wk. V̇o2peak increased 6% in AET and decreased 4% in CON (P < 0.05). Proximal aortic compliance increased (P = 0.04, partial η2 = 0.14) and aortic characteristic impedance decreased (P = 0.02, partial η2 = 0.17) with AET but not CON. Cerebral pulsatility showed a medium-to-large effect size increase with AET, although not statistically significant (P = 0.07, partial η2 = 0.11) compared with CON. Working memory reaction time improved with AET but not CON (P = 0.02, partial η2 = 0.20). Our data suggest 12-wk AET elicited improvements in central vascular hemodynamics (e.g., proximal aortic compliance and characteristic impedance) along with apparent, paradoxical increases in cerebral pulsatile hemodynamics.NEW & NOTEWORTHY We identify differential central versus cerebrovascular responses to 12 wk of aerobic exercise training in middle-aged adults. Although proximal aortic compliance and characteristic impedance improved after 12 wk of exercise, cerebral pulsatility tended to unexpectedly increase. These data suggest short-term aerobic exercise training may lead to more immediate benefits in the central vasculature, whereas longer duration exercise training may be required for beneficial changes in pulsatility within the cerebrovasculature.


Assuntos
Circulação Cerebrovascular , Exercício Físico , Hemodinâmica , Hipertensão , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Exercício Físico/fisiologia , Circulação Cerebrovascular/fisiologia , Hipertensão/fisiopatologia , Hemodinâmica/fisiologia , Rigidez Vascular/fisiologia , Fluxo Pulsátil/fisiologia , Adulto , Aptidão Cardiorrespiratória/fisiologia , Pressão Sanguínea/fisiologia , Projetos Piloto , Artéria Cerebral Média/fisiopatologia , Artéria Cerebral Média/fisiologia , Artéria Cerebral Média/diagnóstico por imagem , Cognição/fisiologia , Terapia por Exercício/métodos
8.
Lab Chip ; 24(9): 2428-2439, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38625094

RESUMO

Rotary blood pumps (RBPs) operating at a constant speed generate non-physiologic blood pressure and flow rate, which can cause endothelial dysfunction, leading to adverse clinical events in peripheral blood vessels and other organs. Notably, pulsatile working modes of the RBP can increase vascular pulsatility to improve arterial endothelial function. However, the laws and related mechanisms of differentially regulating arterial endothelial function under different pulsatile working modes are still unclear. This knowledge gap hinders the optimal selection of the RBP working modes. To address these issues, this study developed a multi-element in vitro endothelial cell culture system (ECCS), which could realize in vitro cell culture effectively and accurately reproduce blood pressure, shear stress, and circumferential strain in the arterial endothelial microenvironment. Performance of this proposed ECCS was validated with numerical simulation and flow experiments. Subsequently, this study investigated the effects of four different pulsation frequency modes that change once every 1-4-fold cardiac cycles (80, 40, 80/3, and 20 cycles per min, respectively) of the RBP on the expression of nitric oxide (NO) and reactive oxygen species (ROS) in endothelial cells. Results indicated that the 2-fold and 3-fold cardiac cycles significantly increased the production of NO and prevented the excessive generation of ROS, potentially minimizing the occurrence of endothelial dysfunction and related adverse events during the RBP support, and were consistent with animal study findings. In general, this study may provide a scientific basis for the optimal selection of the RBP working modes and potential treatment options for heart failure.


Assuntos
Técnicas de Cultura de Células , Fluxo Pulsátil , Humanos , Técnicas de Cultura de Células/instrumentação , Hemodinâmica , Espécies Reativas de Oxigênio/metabolismo , Óxido Nítrico/metabolismo , Coração Auxiliar , Células Endoteliais/citologia , Células Endoteliais/metabolismo , Dispositivos Lab-On-A-Chip , Desenho de Equipamento , Células Endoteliais da Veia Umbilical Humana/metabolismo , Técnicas Analíticas Microfluídicas/instrumentação , Células Cultivadas
10.
J Cardiothorac Vasc Anesth ; 38(6): 1361-1368, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38555215

RESUMO

OBJECTIVES: The aim of this study was to evaluate if the presence of a pulsatile femoral vein pattern is an indicator of venous congestion in the intensive care unit (ICU). DESIGN: Retrospective observational study. SETTING: Three medico-surgical university-affiliated ICUs. PARTICIPANTS: Adult patients who had an ultrasound evaluation at several time points during their ICU stay: at baseline (within 24 hours of admission to ICU), daily during their ICU stay, and within 24 hours before ICU discharge. INTERVENTIONS: At each time point, the hemodynamic, respiratory, and cardiac ultrasound parameters were recorded. The common femoral vein was studied with pulsed-wave Doppler at the level of the femoral trigonum, with high frequency (5-13 MHz) linear array vascular probe and venous vascular mode, in supine patients. MEASUREMENTS AND MAIN RESULTS: One hundred eight patients who underwent 400 ultrasound evaluations (3.7 ± 1 ultrasound evaluations per patient) during their ICU stay were included. Seventy-nine of 108 patients (73%) had a pulsatile femoral vein pattern at least at 1 time point. The multivariable mixed effects logistic regression model demonstrated an association among pulsatile femoral vein pattern, body mass index (OR: 0.91[95% CI 0.85-0.96], p = 0.002), inferior vena cava mean diameter (OR: 2.35 [95% CI 1.18-4.66], p = 0.014), portal vein pulsatility (OR: 2.3 [95% CI 1.2-4.4], p = 0.012), and congestive renal vein flow pattern (OR: 4.02 [95% CI 2.01-8.03], p < 0.001). The results were confirmed by principal component analysis. CONCLUSION: In the ICU, a pulsatile femoral vein pattern is associated with parameters of venous congestion, independently of the patient's volume status, and ventilatory treatment. These results suggest the femoral vein Doppler pulsatility as a parameter of congestion in ICU patients.


Assuntos
Veia Femoral , Unidades de Terapia Intensiva , Fluxo Pulsátil , Humanos , Feminino , Masculino , Estudos Retrospectivos , Veia Femoral/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Fluxo Pulsátil/fisiologia , Hiperemia/diagnóstico por imagem , Hiperemia/fisiopatologia , Adulto , Cuidados Críticos/métodos
11.
Magn Reson Med ; 92(2): 605-617, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38440807

RESUMO

PURPOSE: Directly imaging the function of cerebral perforating arteries could provide valuable insight into the pathology of cerebral small vessel diseases (cSVD). Arterial pulsatility has been identified as a useful biomarker for assessing vascular dysfunction. In this study, we investigate the feasibility and reliability of using dual velocity encoding (VENC) phase-contrast MRI (PC-MRI) to measure the pulsatility of cerebral perforating arteries at 7 T. METHODS: Twenty participants, including 12 young volunteers and 8 elder adults, underwent high-resolution 2D PC-MRI scans with VENCs of 20 cm/s and 40 cm/s at 7T. The sensitivity of perforator detection and the reliability of pulsatility measurement of cerebral perforating arteries using dual-VENC PC-MRI were evaluated by comparison with the single-VENC data. The effects of temporal resolution in the PC-MRI acquisition and aging on the pulsatility measurements were investigated. RESULTS: Compared to the single VENCs, dual-VENC PC-MRI provided improved sensitivity of perforator detection and more reliable pulsatility measurements. Temporal resolution impacted the pulsatility measurements, as decreasing temporal resolution led to an underestimation of pulsatility. Elderly adults had elevated pulsatility in cerebral perforating arteries compared to young adults, but there was no difference in the number of detected perforators between the two age groups. CONCLUSION: Dual-VENC PC-MRI is a reliable imaging method for the assessment of pulsatility of cerebral perforating arteries, which could be useful as a potential imaging biomarker of aging and cSVD.


Assuntos
Artérias Cerebrais , Imageamento por Ressonância Magnética , Fluxo Pulsátil , Humanos , Feminino , Masculino , Adulto , Idoso , Reprodutibilidade dos Testes , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/fisiologia , Fluxo Pulsátil/fisiologia , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Adulto Jovem , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
12.
Magn Reson Med ; 92(1): 332-345, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38469983

RESUMO

PURPOSE: The delay alternating with nutation for tailored excitation (DANTE)-sampling perfection with application-optimized contrasts (SPACE) sequence facilitates 3D intracranial vessel wall imaging with simultaneous suppression of blood and CSF. However, the achieved image contrast depends closely on the selected sequence parameters, and the clinical use of the sequence is limited in vivo by observed signal variations in the vessel wall, CSF, and blood. This paper introduces a comprehensive DANTE-SPACE simulation framework, with the aim of providing a better understanding of the underlying contrast mechanisms and facilitating improved parameter selection and contrast optimization. METHODS: An extended phase graph formalism was developed for efficient spin ensemble simulation of the DANTE-SPACE sequence. Physiological processes such as pulsatile flow velocity variation, varying flow directions, intravoxel velocity variation, diffusion, and B 1 + $$ {\mathrm{B}}_1^{+} $$ effects were included in the framework to represent the mechanisms behind the achieved signal levels accurately. RESULTS: Intravoxel velocity variation improved temporal stability and robustness against small velocity changes. Time-varying pulsatile velocity variation affected CSF simulations, introducing periods of near-zero velocity and partial rephasing. Inclusion of diffusion effects was found to substantially reduce the CSF signal. Blood flow trajectory variations had minor effects, but B 1 + $$ {\mathrm{B}}_1^{+} $$ differences along the trajectory reduced DANTE efficiency in low- B 1 + $$ {\mathrm{B}}_1^{+} $$ areas. Introducing low-velocity pulsatility of both CSF and vessel wall helped explain the in vivo observed signal heterogeneity in both tissue types. CONCLUSION: The presented simulation framework facilitates a more comprehensive optimization of DANTE-SPACE sequence parameters. Furthermore, the simulation framework helps to explain observed contrasts in acquired data.


Assuntos
Algoritmos , Encéfalo , Simulação por Computador , Imageamento Tridimensional , Humanos , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Imageamento Tridimensional/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Fluxo Pulsátil/fisiologia , Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos
13.
Int J Cardiol ; 405: 131969, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38490269

RESUMO

BACKGROUND: Functional abnormalities of the ascending aorta (AA) have been mainly reported in young patients who underwent arterial switch operation (ASO) for transposition of the great arteries (TGA). OBJECTIVES: To compare systolic, diastolic brachial and central blood pressures (bSBP, bDBP, cSBP, cDBP), aortic biomechanical parameters, and left ventricular (LV) afterload criteria in adult ASO patients with healthy controls and to assess their relationships with LV remodeling and aortic size. MATERIALS AND METHODS: Forty-one prospectively enrolled patients (16.8 to 35.8 years) and 41 age- and sex-matched healthy volunteers underwent cardiac MRI to assess LV remodeling with simultaneous brachial BP estimation. After MRI, carotid-femoral tonometry was performed to measure pulse wave velocity (cfPWV), cSBP and cDBP for further calculation of pulse pressure (cPP), AA distensibility (AAD), and AA and LV elastance (AAE, LVE). RESULTS: bSBP, bDBP, cSBP,cDBP and cPP were all significantly higher in ASO group than in controls: cSBP (116.5 ± 13.8 vs 106.1 ± 12.0, p < 0.001), cDBP (72.5 ± 6.9 vs 67.1 ± 9.4, p = 0.002), cPP (44.0 ± 12.1 vs 39.1 ± 8.9, p = 0.003) and not related to aortic size. AAD were decreased in ASO patients vs controls (4.70 ± 2.72 vs 6.69 ± 2.16, p < 0.001). LV mass was correlated with bSBP, cSBP, cPP (ρ = 0.48; p < 0.001), while concentric LV remodeling was correlated with AAE (ρ = 0.60, p < 0.001) and LVE (ρ = 0.32, p = 0.04), but not with distensibility. CONCLUSION: Even without reaching arterial hypertension, aortic sBP and PP are increased in the adult TGA population after ASO, altering the pulsatile components of afterload and contributing to LV concentric remodeling.


Assuntos
Transposição das Grandes Artérias , Transposição dos Grandes Vasos , Remodelação Ventricular , Humanos , Transposição dos Grandes Vasos/cirurgia , Transposição dos Grandes Vasos/fisiopatologia , Transposição dos Grandes Vasos/diagnóstico por imagem , Masculino , Feminino , Adulto , Remodelação Ventricular/fisiologia , Adulto Jovem , Estudos Prospectivos , Adolescente , Pressão Arterial/fisiologia , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Análise de Onda de Pulso , Imagem Cinética por Ressonância Magnética/métodos , Fluxo Pulsátil/fisiologia
15.
Eur J Obstet Gynecol Reprod Biol ; 295: 18-24, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38325239

RESUMO

BACKGROUND: The evidence-based management of human labor includes the antepartum identification of patients at risk for intrapartum hypoxia. However, available evidence has shown that most of the hypoxic-related complications occur among pregnancies classified at low-risk for intrapartum hypoxia, thus suggesting that the current strategy to identify the pregnancies at risk for intrapartum fetal hypoxia has limited accuracy. OBJECTIVE: To evaluate the role of the combined assessment of the cerebroplacental ratio (CPR) and uterine arteries (UtA) Doppler in the prediction of obstetric intervention (OI) for suspected intrapartum fetal compromise (IFC) within a cohort of low-risk singleton term pregnancies in early labor. METHODS: Prospective multicentre observational study conducted across four tertiary Maternity Units between January 2016 and September 2019. Low-risk term pregnancies with spontaneous onset of labor were included. A two-step multivariable model was developed to assess the risk of OI for suspected IFC. The baseline model included antenatal and intrapartum characteristics, while the combined model included antenatal and intrapartum characteristics plus Doppler anomalies such as CPR MoM < 10th percentile and mean UtA Doppler PI MoM ≥ 95th percentile. Predictive performance was determined by receiver-operating characteristics curve analysis. RESULTS: 804 women were included. At logistic regression analysis, CPR MoM < 10th percentile (aOR 1.269, 95 % CI 1.188-1.356, P < 0.001), mean UtA PI MoM ≥ 95th percentile (aOR 1.012, 95 % CI 1.001-1.022, P = 0.04) were independently associated with OI for suspected IFC. At ROC curve analysis, the combined model including antenatal characteristics plus abnormal CPR and mean UtA PI yielded an AUC of 0.78, 95 %CI(0.71-0.85), p < 0.001, which was significantly higher than the baseline model (AUC 0.61, 95 %CI(0.54-0.69), p = 0.007) (p < 0.001). The combined model was associated with a 0.78 (95 % CI 0.67-0.89) sensitivity, 0.68 (95 % CI 0.65-0.72) specificity, 0.15 (95 % CI 0.11-0.19) PPV, and 0.98 (0.96-0.99) NPV, 2.48 (95 % CI 2.07-2.97) LR + and 0.32 (95 % CI 0.19-0.53) LR- for OI due to suspected IFC. CONCLUSIONS: A predictive model including antenatal and intrapartum characteristics combined with abnormal CPR and mean UtA PI has a good capacity to rule out and a moderate capacity to rule in OI due to IFC, albeit with poor predictive value.


Assuntos
Trabalho de Parto , Artéria Uterina , Feminino , Humanos , Recém-Nascido , Gravidez , Hipóxia , Artéria Cerebral Média/diagnóstico por imagem , Valor Preditivo dos Testes , Resultado da Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Fluxo Pulsátil , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Artérias Umbilicais/diagnóstico por imagem , Artéria Uterina/diagnóstico por imagem
16.
Pediatr Nephrol ; 39(7): 2235-2243, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38416215

RESUMO

BACKGROUND: Acute kidney injury (AKI) is a common condition in critically ill children and is associated with increased morbidity and mortality. This study aimed to assess the performance of point-of-care ultrasonography to predict AKI in children undergoing cardiac surgery. METHODS: In this prospective study, consecutive children underwent kidney Doppler ultrasound examination within 24 h following cardiac surgery, and an experienced operator obtained both renal resistive index (RRI) and renal pulsatility index (RPI). AKI was defined by the Kidney Disease Improving Global Outcome (KDIGO) criteria. The primary outcome was the diagnosis of severe AKI (KDIGO stage 2 or 3) on day 3. RESULTS: A total of 58 patients were included. Median age and weight were 12.9 months (IQR 6.0-37.9) and 7.36 kg (IQR 5.19-11.40), respectively. On day 3, 13 patients were classified as having AKI, of which 11 were severe. RRI could effectively predict AKI (area under the ROC curve [AUC] 0.83, 95% CI 0.71-0.92; p < 0.001) as well as RPI (AUC 0.81, 95% CI 0.69-0.90; p < 0.001). The optimal cutoff value for RRI was 0.85 (sensitivity, 73%; specificity, 83%; positive predictive value [PPV], 50%; and negative predictive value [NPV], 93%), while for RPI was 1.95 (sensitivity, 73%; specificity, 78%; PPV, 44%; and NPV, 92%). Similar results were found in the analysis for prediction on day 5. Significant correlations were found between Doppler-based variables and estimated GFR and furosemide dose on day 3. CONCLUSIONS: Kidney Doppler ultrasound may be a promising tool for predicting AKI in children undergoing cardiac surgery.


Assuntos
Injúria Renal Aguda , Procedimentos Cirúrgicos Cardíacos , Valor Preditivo dos Testes , Ultrassonografia Doppler , Humanos , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/diagnóstico por imagem , Masculino , Feminino , Lactente , Estudos Prospectivos , Ultrassonografia Doppler/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Pré-Escolar , Rim/diagnóstico por imagem , Rim/irrigação sanguínea , Rim/fisiopatologia , Artéria Renal/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Fluxo Pulsátil
17.
J Biomech Eng ; 146(8)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38376443

RESUMO

Average-sized microfluidic artificial lungs consisting of rows and columns of fiber bundles with different column to row aspect ratios (AR) are numerically analyzed for flow characteristics, maximum gas transfer performance, minimum pressure drop, and proper wall shear stress (WSS) values in terms of biocompatibility. The flow is fully laminar and assumed to be incompressible and Newtonian. The transport analysis is performed using a combined convection-diffusion model, and the numerical simulations are carried out with the finite element method. The inlet volumetric flow is modeled as a sinusoidal wave function to simulate the cardiac cycle and its effect on the device performance. The model is first validated with experimental studies in steady-state condition and compared with existing correlations for transient conditions. Then, the validated model is used for a parametric study in both steady and pulsatile flow conditions. The results show that increasing the aspect ratio in fiber configuration leads to converging gas transfer, higher pressure drop, and higher WSS. While determining the optimum configuration, the acceptable shear stress levels play a decisive role to ensure biocompatibility. Also, it is observed that the steady analysis underestimates the gas transfer for higher aspect ratios.


Assuntos
Coração , Microfluídica , Fluxo Pulsátil , Pulmão , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Estresse Mecânico , Simulação por Computador
18.
J Clin Ultrasound ; 52(4): 394-404, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38353146

RESUMO

AIM: This study aims to determine whether second-trimester uterine artery (UtA) Doppler combined with first-trimester abnormal pregnancy-associated plasma protein-A (PAPP-A) and ß-human chorionic gonadotropin (ß-Hcg) levels predicts adverse obstetric and neonatal outcomes. MATERIALS AND METHODS: This study of 289 pregnant women included 196 with normal PAPP-A and free ß-HCG values (control group) and 93 with abnormal values (study group) in the first-trimester screening test. Second-trimester UtA Doppler sonography was done in these pregnancies. The perinatal prediction and screening potential of UtA Doppler pulsatility index (PI) parameters were examined in the study group. RESULTS: UtA PI >95 percentile increased birth before the 37th week by 4.46 times, birth before the 34th week by 7.44 times, preeclampsia risk by 3.25 times, fetal growth restriction (FGR) risk by 4.89 times, and neonatal intensive care unit (NICU) admission rates by 3.66 times in the study group (p < 0.05 for all). UtA PI >95 percentile had 49.2% sensitivity and 82.1% specificity for birth before 37 weeks. For birth before 34 weeks, sensitivity was 80.0% and specificity 65.0%. FGR has 70.5% sensitivity and 67.1% specificity. Screening for preeclampsia has 66.6% sensitivity and 61.9% specificity. CONCLUSION: Adding UtA Doppler in the second trimester to pregnancies with abnormal PAPP-A and/or free ß-Hcg values in the first trimester may be a useful screening method for adverse outcomes.


Assuntos
Gonadotropina Coriônica Humana Subunidade beta , Valor Preditivo dos Testes , Resultado da Gravidez , Primeiro Trimestre da Gravidez , Segundo Trimestre da Gravidez , Proteína Plasmática A Associada à Gravidez , Ultrassonografia Doppler , Ultrassonografia Pré-Natal , Artéria Uterina , Humanos , Feminino , Gravidez , Artéria Uterina/diagnóstico por imagem , Proteína Plasmática A Associada à Gravidez/análise , Gonadotropina Coriônica Humana Subunidade beta/sangue , Adulto , Ultrassonografia Pré-Natal/métodos , Segundo Trimestre da Gravidez/sangue , Ultrassonografia Doppler/métodos , Primeiro Trimestre da Gravidez/sangue , Recém-Nascido , Biomarcadores/sangue , Fluxo Pulsátil
19.
Ultrasound Obstet Gynecol ; 63(2): 230-236, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37616530

RESUMO

OBJECTIVE: To validate and extend a model incorporating maternal ophthalmic artery Doppler at 35-37 weeks' gestation in the prediction of subsequent development of pre-eclampsia (PE). METHODS: This was a prospective validation study of screening for PE (defined according to the 2019 American College of Obstetricians and Gynecologists criteria) by maternal ophthalmic artery peak systolic velocity (PSV) ratio in 6746 singleton pregnancies undergoing routine care at 35 + 0 to 36 + 6 weeks' gestation (validation dataset). Additionally, the data from the validation dataset were combined with those of 2287 pregnancies that were previously used for development of the model (training dataset), and the combined data were used to update the original model parameters. The competing-risks model was used to estimate the individual patient-specific risk of delivery with PE at any time and within 3 weeks from assessment by a combination of maternal demographic characteristics and medical history with PSV ratio alone and in combination with the established PE biomarkers of mean arterial pressure (MAP), uterine artery pulsatility index (UtA-PI), serum placental growth factor (PlGF) and serum soluble fms-like tyrosine kinase-1 (sFlt-1). We evaluated the predictive performance of the model by examining, first, the ability to discriminate between the PE and non-PE groups using the area under the receiver-operating-characteristics curve and the detection rate (DR) at fixed screen-positive (SPR) and false-positive rates of 10% and, second, calibration by measuring the calibration slope and calibration-in-the-large. McNemar's test was used to compare the performance of screening by a biophysical test (maternal factors, MAP, UtA-PI and PSV ratio) vs a biochemical test (maternal factors, PlGF and sFlt-1), low PlGF concentration (< 10th percentile) or high sFlt-1/PlGF concentration ratio (> 90th percentile). RESULTS: In the validation dataset, the performance of screening by maternal factors and PSV ratio for delivery with PE within 3 weeks and at any time after assessment was consistent with that in the training dataset, and there was good agreement between the predicted and observed incidence of PE. In the combined data from the training and validation datasets, good prediction for PE was achieved in screening by a combination of maternal factors, MAP, UtA-PI, PlGF, sFlt-1 and PSV ratio, with a DR, at a 10% SPR, of 85.0% (95% CI, 76.5-91.4%) for delivery with PE within 3 weeks and 65.7% (95% CI, 59.2-71.7%) for delivery with PE at any time after assessment. The performance of a biophysical test was superior to that of screening by low PlGF concentration or high sFlt-1/PlGF concentration ratio but not significantly different from the performance of a biochemical test combining maternal factors with PlGF and sFlt-1 for both PE within 3 weeks and PE at any time after assessment. CONCLUSION: Maternal ophthalmic artery PSV ratio at 35-37 weeks' gestation in combination with other biomarkers provides effective prediction of subsequent development of PE. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Pré-Eclâmpsia , Gravidez , Feminino , Humanos , Pré-Eclâmpsia/diagnóstico por imagem , Fator de Crescimento Placentário , Terceiro Trimestre da Gravidez , Artéria Oftálmica/diagnóstico por imagem , Biomarcadores , Artéria Uterina/diagnóstico por imagem , Fluxo Pulsátil , Receptor 1 de Fatores de Crescimento do Endotélio Vascular , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...