Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
1.
Anal Chim Acta ; 1309: 342671, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38772664

RESUMO

Electrochemical biosensors, known for their low cost, sensitivity, selectivity, and miniaturization capabilities, are ideal for point-of-care devices. The magnetic metal-organic framework (MMOF), synthesized using the in-situ growth method, consists of ferric salt, magnetic nanoparticles, histidine, and benzene tetracarboxylic acid. MMOF was sequentially modified with aptamer-biotin and streptavidin-horseradish peroxidase, serving as a detector for spike protein and a transducer converting electrochemical signals using H2O2-hydroquinone on a screen-printed electrode. MMOF facilitates easy washing and homogeneous deposition on the working electrode with a magnet, enhancing sensitivity and reducing noise. The physical and electrochemical properties of the modified MMOFs were thoroughly characterized using various analytical techniques. The aptasensors' performance achieved a detection limit of 6 pM for voltammetry and 5.12 pM for impedance spectroscopy in human serum samples. This cost-effective, portable MMOF platform is suitable for rapid point-of-care testing for SARS-CoV-2 spike proteins.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Eletroquímicas , Limite de Detecção , Estruturas Metalorgânicas , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Estruturas Metalorgânicas/química , Glicoproteína da Espícula de Coronavírus/análise , Aptâmeros de Nucleotídeos/química , Humanos , Técnicas Biossensoriais/métodos , SARS-CoV-2/isolamento & purificação , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , COVID-19/diagnóstico , COVID-19/virologia , Nanopartículas de Magnetita/química , Eletrodos
2.
Anal Chem ; 96(21): 8830-8836, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38693713

RESUMO

Microbial surface transmission has aroused great attention since the pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Developing a simple in situ detection method for viruses on solid surfaces is of great significance for timely public health surveillance. Taking advantage of the natural structure of SARS-CoV-2, we reported the assembly of Au@AgNPs on the surface of a single virus by the specific aptamer-spike protein interaction. Multiple hotspots can be created between the neighboring Au@AgNPs for the highly sensitive surface-enhanced Raman scattering (SERS) detection of SARS-CoV-2. Using two different aptamers labeled with Cy3 and Au@AgNPs, in situ SERS detection of pseudotyped SARS-CoV-2 (PSV) on packaging surfaces was achieved within 20 min, with a detection limit of 5.26 TCID50/mL. For the blind testing of 20 PSV-contaminated packaging samples, this SERS aptasensor had a sensitivity of 100% and an accuracy of 100%. This assay has been successfully applied to in situ detection of PSV on the surfaces of different packaging materials, suggesting its potential applicability.


Assuntos
Aptâmeros de Nucleotídeos , COVID-19 , Ouro , Limite de Detecção , Nanopartículas Metálicas , SARS-CoV-2 , Prata , Análise Espectral Raman , SARS-CoV-2/isolamento & purificação , Análise Espectral Raman/métodos , Ouro/química , Nanopartículas Metálicas/química , COVID-19/diagnóstico , COVID-19/virologia , Prata/química , Aptâmeros de Nucleotídeos/química , Humanos , Glicoproteína da Espícula de Coronavírus/análise , Propriedades de Superfície
3.
J Nanobiotechnology ; 22(1): 239, 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38735951

RESUMO

Widespread distribution of porcine epidemic diarrhea virus (PEDV) has led to catastrophic losses to the global pig farming industry. As a result, there is an urgent need for rapid, sensitive and accurate tests for PEDV to enable timely and effective interventions. In the present study, we develop and validate a floating gate carbon nanotubes field-effect transistor (FG CNT-FET)-based portable immunosensor for rapid identification of PEDV in a sensitive and accurate manner. To improve the affinity, a unique PEDV spike protein-specific monoclonal antibody is prepared by purification, and subsequently modified on FG CNT-FET sensor to recognize PEDV. The developed FET biosensor enables highly sensitive detection (LoD: 8.1 fg/mL and 100.14 TCID50/mL for recombinant spike proteins and PEDV, respectively), as well as satisfactory specificity. Notably, an integrated portable platform consisting of a pluggable FG CNT-FET chip and a portable device can discriminate PEDV positive from negative samples and even identify PEDV and porcine deltacoronavirus within 1 min with 100% accuracy. The portable sensing platform offers the capability to quickly, sensitively and accurately identify PEDV, which further points to a possibility of point of care (POC) applications of large-scale surveillance in pig breeding facilities.


Assuntos
Técnicas Biossensoriais , Nanotubos de Carbono , Vírus da Diarreia Epidêmica Suína , Vírus da Diarreia Epidêmica Suína/isolamento & purificação , Animais , Suínos , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Nanotubos de Carbono/química , Limite de Detecção , Imunoensaio/métodos , Imunoensaio/instrumentação , Anticorpos Monoclonais/imunologia , Transistores Eletrônicos , Doenças dos Suínos/diagnóstico , Doenças dos Suínos/virologia , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/análise , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/veterinária , Infecções por Coronavirus/virologia , Anticorpos Antivirais/imunologia , Desenho de Equipamento
4.
Talanta ; 276: 126293, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38788383

RESUMO

In this work we present the development of an electrochemiluminescence aptasensor based on electrografting molybdenum disulphide nanosheets functionalized with diazonium salt (MoS2-N2+) upon screen-printed electrodes of graphene (SPEs GPH) for viral proteins detection. In brief, this aptasensor consists of SPEs GPH electrografted with MoS2-N2+ and modified with a thiolated aptamer, which can specifically recognize the target protein analyte. In this case, we have used SARS-CoV-2 spike protein as model protein. Electrochemiluminescence detection was performed by using the [Ru(bpy)3]2+/TPRA (tripropylamine) system, which allows the specific detection of the SARS-CoV-2 spike protein easily and rapidly with a detection limit of 9.74 fg/mL and a linear range from 32.5 fg/mL to 50.0 pg/mL. Moreover, the applicability of the aptasensor has been confirmed by the detection of the protein directly in human saliva samples. Comparing our device with a traditional saliva antigen test, our aptasensor can detect the spike protein even when the saliva antigen test gives a negative result.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Dissulfetos , Técnicas Eletroquímicas , Grafite , Medições Luminescentes , Molibdênio , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Grafite/química , Dissulfetos/química , Molibdênio/química , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/imunologia , Humanos , Medições Luminescentes/métodos , Glicoproteína da Espícula de Coronavírus/análise , Limite de Detecção , COVID-19/diagnóstico , COVID-19/virologia , Eletrodos , Saliva/química , Saliva/virologia
5.
ACS Appl Mater Interfaces ; 16(23): 30196-30208, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38814245

RESUMO

Rapid and reliable immunosensing is undoubtedly one of the priorities in the efficient management and combat against a pandemic, as society has experienced with the SARS-CoV-2 outbreak; simple and cost-effective sensing strategies are at the forefront of these efforts. In this regard, 2D-layered MXenes hold great potential for electrochemical biosensing due to their attractive physicochemical properties. Herein, we present a V2CTx MXene-based sensing layer as an integral part of a label-free immunosensor for sensitive and selective detection of the SARS-CoV-2 spike protein. The sensor was fabricated on a supporting screen-printed carbon electrode using Nafion as an immobilizing agent for MXene and glutaraldehyde, the latter enabling effective binding of protein A for further site-oriented immobilization of anti-SARS-CoV-2 antibodies. A thorough structural analysis of the sensor architecture was carried out, and several key parameters affecting the fabrication and analytical performance of the immunosensor were investigated and optimized. The immunosensor showed excellent electroanalytical performance in combination with an impedimetric approach and exhibited a low detection limit of only 45 fM SARS-CoV-2 spike protein. Its practical applicability was successfully demonstrated by measuring the spike protein in a spiked artificial nasopharyngeal fluid sample.


Assuntos
Técnicas Biossensoriais , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/análise , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/imunologia , Técnicas Biossensoriais/métodos , Humanos , Imunoensaio/métodos , Limite de Detecção , COVID-19/diagnóstico , COVID-19/virologia , Técnicas Eletroquímicas/métodos , Eletrodos
6.
Bioelectrochemistry ; 158: 108722, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38697015

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) diagnosis is the need of the hour, as cases are persistently increasing, and new variants are constantly emerging. The ever-changing nature of the virus leading to multiple variants, has brought an imminent need for early, accurate and rapid detection methods. Herein, we have reported the design and fabrication of Screen-Printed Electrodes (SPEs) with graphene oxide (GO) as working electrode and modified with specific antibodies for SARS-CoV-2 Receptor Binding Domain (RBD). Flexibility of design, and portable nature has made SPEs the superior choice for electrochemical analysis. The developed immunosensor can detect RBD as low as 0.83 fM with long-term storage capacity. The fabricated SPEs immunosensor was tested using a miniaturized portable device and potentiostat on 100 patient nasopharyngeal samples and corroborated with RT-PCR data, displayed 94 % sensitivity. Additionally, the in-house developed polyclonal antibodies detected RBD antigen of the mutated Omicron variant of SARS-CoV-2 successfully. We have not observed any cross-reactivity/binding of the fabricated immunosensor with MERS (cross-reactive antigen) and Influenza A H1N1 (antigen sharing common symptoms). Hence, the developed SPEs sensor may be applied for bedside point-of-care diagnosis of SARS-CoV-2 using miniaturized portable device, in clinical samples.


Assuntos
Técnicas Biossensoriais , COVID-19 , Eletrodos , Grafite , SARS-CoV-2 , Grafite/química , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Imunoensaio/instrumentação , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/análise , Limite de Detecção
7.
Biosens Bioelectron ; 257: 116171, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38636317

RESUMO

The COVID-19 pandemic has highlighted the need for rapid and sensitive detection of SARS-CoV-2. Here, we report an ultrasensitive SARS-CoV-2 immunosensor by integration of an AlGaN/GaN high-electron-mobility transistor (HEMT) and anti-SARS-CoV-2 spike protein antibody. The AlGaN/GaN HEMT immunosensor has demonstrated the capability to detect SARS-CoV-2 spike proteins at an impressively low concentration of 10-22 M. The sensor was also applied to pseudoviruses and SARS-CoV-2 ΔN virions that display the Spike proteins with a single virion particle sensitivity. These features validate the potential of AlGaN/GaN HEMT biosensors for point of care tests targeting SARS-CoV-2. This research not only provides the first HEMT biosensing platform for ultrasensitive and label-free detection of SARS-CoV-2.


Assuntos
Técnicas Biossensoriais , COVID-19 , Gálio , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Transistores Eletrônicos , Vírion , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/imunologia , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/análise , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Gálio/química , Vírion/isolamento & purificação , Vírion/química , Limite de Detecção , Compostos de Alumínio/química , Desenho de Equipamento , Imunoensaio/instrumentação , Imunoensaio/métodos , Anticorpos Imobilizados/química , Anticorpos Antivirais
8.
Talanta ; 274: 125986, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38537348

RESUMO

The outbreak of novel coronavirus pneumonia (COVID-19) in 2019 has garnered widespread attention. The virus exhibits high contagiousness, and in certain cases, it can lead to recurrent infections. Therefore, it is imperative to develop portable, sensitive, and accurate sensors to promptly detect infected individuals, control the virus's transmission, and determine suitable treatment strategies. In this study, we proposed a magnetically-assisted method employing CFO@CS-Au MNP as the substrate material, which was functionalized with human angiotensin-converting enzyme (ACE2) for efficient capture of SARS-CoV-2 spike protein in solution. Subsequently, the captured protein was sensitively detected through differential pulse voltammetry (DPV) electrical analysis. The linear detection range of the labeled GCE/MNP/GA/ACE2/BSA electrochemical sensor is from 1 pg/mL to 10 µg/mL, with a minimum detection limit of 0.15 pg/mL. Furthermore, the fabricated GCE/MNP/GA/ACE2/BSA sensor achieved satisfactory recoveries of SARS-CoV-2 spike protein in saliva and nasal swab samples within 10 min. These results indicate that this magnetically-assisted biosensor has established a solid foundation for the swift on-site detection of COVID-19.


Assuntos
Técnicas Biossensoriais , COVID-19 , Técnicas Eletroquímicas , Limite de Detecção , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Glicoproteína da Espícula de Coronavírus/análise , Técnicas Biossensoriais/métodos , Humanos , SARS-CoV-2/isolamento & purificação , Técnicas Eletroquímicas/métodos , COVID-19/diagnóstico , COVID-19/virologia , Enzima de Conversão de Angiotensina 2/metabolismo , Cobalto/química , Saliva/virologia , Saliva/química , Compostos Férricos/química , Nanoestruturas/química
9.
Front Immunol ; 14: 1111644, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36911726

RESUMO

Development and validation of rapid and easy-to-perform diagnostics continue to be a high priority during the current COVID-19 pandemic. Although vaccines are now widely available, early detection and consistent transmission control provide ideal means to mitigate the spread of SARS-CoV-2. Nucleic acid-based real-time PCR tests are widely acknowledged as the gold standard for reliable diagnosis of COVID-19 infection. These tests are based on detecting viable or nonviable viral nucleic acids. SARS-CoV-2 spike protein is an alternative and ideal target for SARS-CoV-2 diagnosis in the early phase of infection, but point-of-care kits to detect the SARS-CoV-2 spike protein are limited. Here we describe a rapid and convenient method based on Lateral Flow Immunoassay (LFIA) to detect SARS-CoV-2 spike proteins, including SARS-CoV-2 variants (A.23.1, B.1.1.1, 1.617.2, B.1.1.7, B.1.351, P.1, N501Y, R.1, P681H, P3, UK, and South African) within 5 to 10 minutes. We generated highly specific monoclonal antibodies (mAbs) against rationally designed SARS-CoV-2 spike protein. Matched pair mAbs were selected by epitope mapping and employed as antigen capture reagents by spotting onto a nitrocellulose membrane and as detector reagents by conjugation with colloidal gold nanoparticles. We evaluated the performance of the LFIA using recombinant spike proteins of SARS-CoV-2 and several SARS-CoV-2 variants. The specificity of the LFIA was assessed using heat-inactivated SARS-CoV-2 and related human coronaviruses (HCoV-OC43, HCoV-229E, HCoV-HKU1, and HCoV-NL63) and an FDA-approved respiratory pathogens (RP) panel. The assay exhibited 98% specificity and acceptable performance with respect to the minimum limit of detection (25 ng/test) in validation tests. This new LFIA provides improved performance for the early diagnosis of SARS-CoV-2, particularly for home monitoring and in situations with limited access to molecular methods.


Assuntos
COVID-19 , Nanopartículas Metálicas , Humanos , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/análise , Teste para COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito , Pandemias , Ouro , Sensibilidade e Especificidade , Imunoensaio/métodos
10.
ACS Appl Mater Interfaces ; 14(39): 44713-44723, 2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-36083630

RESUMO

Early and reliable detection of an infectious viral disease is critical to accurately monitor outbreaks and to provide individuals and health care professionals the opportunity to treat patients at the early stages of a disease. The accuracy of such information is essential to define appropriate actions to protect the population and to reduce the likelihood of a possible pandemic. Here, we show the fabrication of freestanding laser-induced graphene (FLIG) flakes that are highly sensitive sensors for high-fidelity viral detection. As a case study, we show the detection of SARS-CoV-2 spike proteins. FLIG flakes are nonembedded porous graphene foams ca. 30 µm thick that are generated using laser irradiation of polyimide and can be fabricated in seconds at a low cost. Larger pieces of FLIG were cut forming a cantilever, used as suspended resonators, and characterized for their electromechanics behavior. Thermomechanical analysis showed FLIG stiffness comparable to other porous materials such as boron nitride foam, and electrostatic excitation showed amplification of the vibrations at frequencies in the range of several kilo-hertz. We developed a protocol for aqueous biological sensing by characterizing the wetting dynamic response of the sensor in buffer solution and in water, and devices functionalized with COVID-19 antibodies specifically detected SARS-CoV-2 spike protein binding, while not detecting other viruses such as MS2. The FLIG sensors showed a clear mass-dependent frequency response shift of ∼1 Hz/pg, and low nanomolar concentrations could be detected. Ultimately, the sensors demonstrated an outstanding limit of detection of 2.63 pg, which is equivalent to as few as ∼5000 SARS-CoV-2 viruses. Thus, the FLIG platform technology can be utilized to develop portable and highly accurate sensors, including biological applications where the fast and reliable protein or infectious particle detection is critical.


Assuntos
COVID-19 , Grafite , COVID-19/diagnóstico , Grafite/química , Humanos , Lasers , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/análise , Água
11.
J Clin Virol ; 155: 105269, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36029637

RESUMO

BACKGROUND: The concentration of antibodies against the SARS-CoV-2 spike protein is frequently being measured for clinical and epidemiological purposes. The aim of this study was to examine whether the results of different quantitative SARS-CoV-2 spike antibody assays are comparable. MATERIAL AND METHODS: The Siemens SARS-CoV-2 IgG, Abbott SARS-CoV-2 IgG II Quant, Roche ElecsysT Anti-SARS-CoV-2 S, and Euroimmun Anti-SARS-CoV-2-QuantiVac assay were compared with 110 sera from patients 6-9 months after SARS-CoV-2 infection and the WHO First International SARS-CoV-2 antibody standard 20/136. The antibody values were converted into WHO binding antibody units (BAU)/ml. The diagnostic sensitivity of the assays was determined and the antibody values were compared. RESULTS: The diagnostic sensitivity ranged from 57.3% (Euroimmun) to 100% (Roche). The antibody concentration values of different assays correlated with Pearson coefficients of correlation between 0.729 and 0.953. The geometric mean antibody values of the Abbott, Siemens and Euroimmun assay varied by a factor of 1.1-1.2. The geometric mean antibody values of the Roche assay were 2.4-2.8 times higher than those from the other assays. The assays yielded varying results with the WHO International antibody standard. CONCLUSIONS: The quantitative SARS-CoV-2 antibody assays from Abbott, Siemens, Roche and Euroimmun correlate strongly but differ in the antibody concentrations. Therefore, the same assay should be used when testing patients repeatedly. In addition, the name of the assay used and the manufacturer should be indicated along with the test results.


Assuntos
COVID-19 , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Anticorpos Antivirais , COVID-19/diagnóstico , Humanos , Imunoglobulina G , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus/análise , Glicoproteína da Espícula de Coronavírus/química
12.
Orv Hetil ; 163(25): 975-983, 2022 Jun 19.
Artigo em Húngaro | MEDLINE | ID: mdl-35895554

RESUMO

Introduction: The COVID-19 (coronavirus disease 2019) caused by SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) is associated with high mortality rates worldwide. Polymerase chain reaction (PCR) is extensively used for virus detection in both infected patients and deceased persons. PCR, however, gives no information about the localization of the virus in cells and tissues. Detection of spike and nucleocapsid proteins and viral ribonucleic acid (RNA) of the SARS-CoV-2 in situ might provide more information and aid in the discovery of the pathomechanism of cellular damage. There are several commercially available anti-spike and anti-nucleocapsid antibodies used to detect immunohistochemical reactions, though each gives different results. Objective: The goal of the present study was to compare the intensity and specificity of several anti-spike and antinucleocapsid antibodies in different dilutions in four Hungarian university departments. Method: Immunohistochemical reactions were performed on coded slides taken from infected lungs of 3 deceased and placenta samples with appropriate negative controls of formalin-fixed paraffin-embedded tissues, scanned, evaluated unanimously and analysed statistically by the assessors. Results: By comparing the intensity, dilution, background and reproducibility of the different primary antibodies, it was possible to select the antibodies with the best results. Conclusion: The antibodies selected with established dilutions can be used in further studies to detect SARS-CoV-2 proteins in surgical materials and in samples obtained during autopsy.


Assuntos
Teste para COVID-19 , COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , COVID-19/diagnóstico , Teste para COVID-19/métodos , Feminino , Humanos , Proteínas do Nucleocapsídeo/análise , Gravidez , Reprodutibilidade dos Testes , SARS-CoV-2/isolamento & purificação , Glicoproteína da Espícula de Coronavírus/análise
13.
Chemosphere ; 306: 135578, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35798154

RESUMO

Overexpression of proteins/antigens and other gene-related sequences in the bodies could lead to significant mutations and refractory diseases. Detection and identification of assorted trace concentrations of such proteins/antigens and/or gene-related sequences remain challenging, affecting different pathogens and making viruses stronger. Correspondingly, coronavirus (SARS-CoV-2) mutations/alterations and spread could lead to overexpression of ssDNA and the related antigens in the population and brisk activity in gene-editing technologies in the treatment/detection may lead to the presence of pCRISPR in the blood. Therefore, the detection and evaluation of their trace concentrations are of critical importance. CaZnO-based nanoghosts (NGs) were synthesized with the assistance of a high-gravity technique at a 1,800 MHz field, capitalizing on the use of Rosmarinus officinalis leaf extract as the templating agent. A complete chemical, physical and biological investigation revealed that the synthesized NGs presented similar morphological features to the mesenchymal stem cells (MSCs), resulting in excellent biocompatibility, interaction with ssDNA- and/or pCRISPR-surface, through various chemical and physical mechanisms. This comprise the unprecedented synthesis of a fully inorganic nanostructure with behavior that is similar to MSCs. Furthermore, the endowed exceptional ability of inorganic NGs for detective sensing/folding of ssDNA and pCRISPR and recombinant SARS-CoV-2 spike antigen (RSCSA), along with in-situ hydrogen peroxide detection on the HEK-293 and HeLa cell lines, was discerned. On average, they displayed a high drug loading capacity of 55%, and the acceptable internalizations inside the HT-29 cell lines affirmed the anticipated MSCs-like behavior of these inorganic-NGs.


Assuntos
DNA de Cadeia Simples , Doxorrubicina , Sistemas de Liberação de Fármacos por Nanopartículas , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Cálcio , DNA de Cadeia Simples/análise , Doxorrubicina/administração & dosagem , Células HEK293 , Células HeLa , Humanos , Glicoproteína da Espícula de Coronavírus/análise , Glicoproteína da Espícula de Coronavírus/genética , Óxido de Zinco
14.
Biosensors (Basel) ; 12(6)2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35735573

RESUMO

An IoT-WiFi smart and portable electrochemical immunosensor for the quantification of SARS-CoV-2 spike protein was developed with integrated machine learning features. The immunoenzymatic sensor is based on the immobilization of monoclonal antibodies directed at the SARS-CoV-2 S1 subunit on Screen-Printed Electrodes functionalized with gold nanoparticles. The analytical protocol involves a single-step sample incubation. Immunosensor performance was validated in a viral transfer medium which is commonly used for the desorption of nasopharyngeal swabs. Remarkable specificity of the response was demonstrated by testing H1N1 Hemagglutinin from swine-origin influenza A virus and Spike Protein S1 from Middle East respiratory syndrome coronavirus. Machine learning was successfully used for data processing and analysis. Different support vector machine classifiers were evaluated, proving that algorithms affect the classifier accuracy. The test accuracy of the best classification model in terms of true positive/true negative sample classification was 97.3%. In addition, the ML algorithm can be easily integrated into cloud-based portable Wi-Fi devices. Finally, the immunosensor was successfully tested using a third generation replicating incompetent lentiviral vector pseudotyped with SARS-CoV-2 spike glycoprotein, thus proving the applicability of the immunosensor to whole virus detection.


Assuntos
Técnicas Biossensoriais , COVID-19 , Vírus da Influenza A Subtipo H1N1 , Nanopartículas Metálicas , COVID-19/diagnóstico , Ouro , Humanos , Imunoensaio/métodos , Aprendizado de Máquina , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/análise
15.
Biosens Bioelectron ; 212: 114406, 2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-35635976

RESUMO

Coronavirus Disease 2019 (COVID-19) pandemic has shown the need for early diagnosis to manage infectious disease outbreaks. Here, we report a label free electrochemical Fluorine-Doped Tin Oxide (FTO) Immunosensor coupled with gold nanorods (GNRs) as an electron carrier for ultrasensitive detection of the Receptor Binding Domain (RBD) of SARS CoV-2 Spike protein. The RBD gene was cloned, and expressed in-house with confirmed molecular weight of ∼31 kDa via Sodium Dodecyl Sulphate-Polyacrylamide Gel Electrophoresis (SDS-PAGE) and Matrix-Assisted Laser Desorption/Ionization-Time of Flight (MALDI-TOF). RBD antibodies (Ab) were generated to be used as a bioreceptor for sensor fabrication, and characterized using SDS-PAGE, Western Blot, and Enzyme-Linked Immunosorbent Assay (ELISA). GNRs were fabricated on the electrode surface, followed by immobilization of RBD Ab. The conjugation steps were confirmed by UV-Vis Spectroscopy, Dynamic Light Scattering (DLS), Atomic Force Microscopy (AFM), Transmission Electron Microscopy (TEM), Cyclic Voltammetry (CV), and Differential Pulse Voltammetry (DPV). The fabricated electrode was further optimized for maximum efficiency and output. The detection limit of the developed electrode was determined as 0.73 fM for RBD antigen (Ag). Furthermore, the patient nasopharyngeal samples were collected in Viral Transport Media (VTM), and tested on the sensor surface that resulted in detection of SARS CoV-2 within 30 s, which was further validated via Reverse Transcription-Polymerase Chain Reaction (RT-PCR). Moreover, the immunosensor showed good repeatability, storage stability, and minimal cross reactivity against Middle East Respiratory Syndrome (MERS) spike protein. Along with ease of fabrication, the electrodes show future miniaturization potential for extensive and rapid screening of populations for COVID-19.


Assuntos
Técnicas Biossensoriais , COVID-19 , Nanotubos , Técnicas Biossensoriais/métodos , COVID-19/diagnóstico , Proteínas de Transporte , Ouro , Humanos , Imunoensaio/métodos , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/análise
16.
J Vis Exp ; (182)2022 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-35532236

RESUMO

The development of new technologies for cellular fluorescence microscopy has facilitated high-throughput screening methods for drug discovery. Quantum dots are fluorescent nanoparticles with excellent photophysical properties imbued with bright and stable photoluminescence as well as narrow emission bands. Quantum dots are spherical in shape, and with the proper modification of the surface chemistry, can be used to conjugate biomolecules for cellular applications. These optical properties, combined with the ability to functionalize them with biomolecules, make them an excellent tool for investigating receptor-ligand interactions and cellular trafficking. Here, we present a method that uses quantum dots to track the binding and endocytosis of SARS-CoV-2 spike protein. This protocol can be used as a guide for experimentalists looking to utilize quantum dots to study protein-protein interactions and trafficking in the context of cellular physiology.


Assuntos
Endocitose , Pontos Quânticos , Glicoproteína da Espícula de Coronavírus , Células HEK293 , Humanos , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/análise
17.
Biosensors (Basel) ; 12(4)2022 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-35448292

RESUMO

Simple, timely, and precise detection of SARS-CoV-2 in clinical samples and contaminated surfaces aids in lowering attendant morbidity/mortality related to this infectious virus. Currently applied diagnostic techniques depend on a timely laboratory report following PCR testing. However, the application of these tests is associated with inherent shortcomings due to the need for trained personnel, long-time centralized laboratories, and expensive instruments. Therefore, there is an interest in developing biosensing diagnostic frontiers that can help in eliminating these shortcomings with a relatively economical, easy-to-use, well-timed, precise and sensitive technology. This study reports the development of fabricated Q-tips designed to qualitatively and semi-quantitatively detect SARS-CoV-2 in clinical samples and contaminated non-absorbable surfaces. This colorimetric sensor is engineered to sandwich SARS-CoV-2 spike protein between the lactoferrin general capturing agent and the complementary ACE2-labeled receptor. The ACE2 receptor is decorated with an orange-colored polymeric nanoparticle to generate an optical visual signal upon pairing with the SARS-CoV-2 spike protein. This colorimetric change of the Q-tip testing zone from white to orange confirms a positive result. The visual detection limit of the COVID-19 engineered colorimetric Q-tip sensor was 100 pfu/mL within a relatively short turnaround time of 5 min. The linear working range of quantitation was 103-108 pfu/mL. The engineered sensor selectively targeted SARS-CoV-2 spike protein and did not bind to another coronavirus such as MERS-CoV, Flu A, or Flu B present on the contaminated surface. This novel detection tool is relatively cheap to produce and suitable for onsite detection of COVID-19 infection.


Assuntos
COVID-19 , SARS-CoV-2 , Enzima de Conversão de Angiotensina 2 , COVID-19/diagnóstico , Humanos , Glicoproteína da Espícula de Coronavírus/análise
18.
Mod Pathol ; 35(9): 1175-1180, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35361888

RESUMO

Current public health initiatives to contain the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) global pandemic focus on expanding vaccination efforts to include vulnerable populations such as pregnant people. Vaccines using messenger ribonucleic acid (mRNA) technology rely on translation by immune cells, primarily at the injection site. Hesitancy remains among the general population regarding the safety of mRNA vaccines during gestation, and it remains unknown whether the SARS-CoV-2 Spike protein (the product of mRNA vaccines available) accumulates in the placenta after vaccination. Objective: To determine whether Spike protein translation and accumulation occurs in placental tissue in the context of recent mRNA SARC-CoV-2 vaccination during pregnancy. We identified 48 patients receiving one or two doses of mRNA SARS-CoV-2 vaccine during gestation and used immunohistochemistry against SARS-CoV-2 Spike protein in formalin-fixed, paraffin-embedded placental tissue. One placenta, positive for SARS-CoV-2 RNA by in situ hybridization (ISH) was used as positive control. Seven term placentas collected prior to the emergence of SARS-CoV-2 served as negative controls. Eighty one percent of patients in the study group underwent third-trimester delivery; remaining had a first-trimester spontaneous abortion or elective second-trimester termination. Patients received two (52%) or one (48%) vaccine doses during pregnancy, with a median interval between latest dose and delivery of 13 days (range 2-79 days). Most (63%) cases had their latest dose within 15 days prior to delivery. All the placentas in the study and negative control groups were negative for SARS-CoV-2 immunohistochemistry. Six study cases with short vaccine-delivery intervals (2-7 days) were subjected to SARS-CoV-2 ISH and were negative. Our findings suggest that mRNA vaccines do not reach significant concentrations in the placenta given the absence of definitive SARS-CoV-2 Spike protein accumulation in placental tissue. This observation provides evidence supporting the safety of mRNA vaccines to the placental-fetal unit.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Placenta , Complicações Infecciosas na Gravidez , Glicoproteína da Espícula de Coronavírus , COVID-19/prevenção & controle , Vacinas contra COVID-19/administração & dosagem , Feminino , Humanos , Placenta/virologia , Gravidez , Complicações Infecciosas na Gravidez/prevenção & controle , Complicações Infecciosas na Gravidez/virologia , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus/análise , Vacinação
19.
Anal Biochem ; 645: 114633, 2022 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-35247355

RESUMO

The rapid spread of SARS-CoV-2 infection throughout the world led to a global public health and economic crisis triggering an urgent need for the development of low-cost vaccines, therapies and high-throughput detection assays. In this work, we used a combination of Ideal-Filter Capillary Electrophoresis SELEX (IFCE-SELEX), Next Generation Sequencing (NGS) and binding assays to isolate and validate single-stranded DNA aptamers that can specifically recognize the SARS-CoV-2 Spike glycoprotein. Two selected non-competing DNA aptamers, C7 and C9 were successfully used as sensitive and specific biological recognition elements for the development of electrochemical and fluorescent aptasensors for the SARS-CoV-2 Spike glycoprotein with detection limits of 0.07 fM and 41.87 nM, respectively.


Assuntos
Aptâmeros de Nucleotídeos , COVID-19 , Aptâmeros de Nucleotídeos/genética , COVID-19/diagnóstico , Humanos , SARS-CoV-2/genética , Técnica de Seleção de Aptâmeros , Glicoproteína da Espícula de Coronavírus/análise , Glicoproteína da Espícula de Coronavírus/genética , Glicoproteína da Espícula de Coronavírus/metabolismo
20.
Microbiol Spectr ; 10(1): e0256321, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35196819

RESUMO

We have previously used composite reference standards and latent class analysis (LCA) to evaluate the performance of laboratory assays in the presence of tarnished gold standards. Here, we apply these techniques to repeated, cross-sectional study of Canadian blood donors, whose sera underwent parallel testing with four separate SARS-CoV-2 antibody assays. We designed a repeated cross-sectional design with random cross-sectional sampling of all available retention samples (n = 1500/month) for a 12 -month period from April 2020 until March 2021. Each sample was evaluated for SARS-CoV-2 IgG antibodies using four assays an Abbott Architect assay targeting the nucleocapsid antigen (Abbott-NP, Abbott, Chicago IL) and three in-house IgG ELISAs recognizing distinct recombinant viral antigens: full-length spike glycoprotein (Spike), spike glycoprotein receptor binding domain (RBD) and nucleocapsid (NP). We used two analytic approaches to estimate SAR-CoV-2 seroprevalence: a composite reference standard and LCA. Using LCA to estimate true seropositivity status based on the results of the four antibody tests, we estimated that seroprevalence increased from 0.8% (95% CI: 0.5-1.4%) in April 2020 to 6.3% (95% CI: 5.1-7.6%) in March 2021. Our study provides further support for the use of LCA in upcoming public health crises, epidemics, and pandemics when a gold standard assay may not be available or identifiable. IMPORTANCE Here, we describe an approach to estimating seroprevalence in a low prevalence setting when multiple assays are available and yet no known gold standard exists. Because serological studies identify cases through both diagnostic testing and surveillance, and otherwise silent, unrecognized infections, serological data can be used to estimate the true infection fatality ratio of a disease. However, seroprevalence studies rely on assays with imperfect sensitivity and specificity. Seroreversion (loss of antibody response) also occurs over time, and with the advent of vaccination, distinction of antibody response resulting from vaccination as opposed to antibody response due to infection has posed an additional challenge. Our approach indicates that seroprevalence on Canadian blood donors by the end of March 2021was less than 10%. Our study supports the use of latent class analysis in upcoming public health crises, epidemics, and pandemics when a gold standard assay may not be available or identifiable.


Assuntos
Anticorpos Antivirais/sangue , Doadores de Sangue/estatística & dados numéricos , COVID-19/sangue , SARS-CoV-2/imunologia , Adulto , Idoso , COVID-19/epidemiologia , COVID-19/virologia , Canadá/epidemiologia , Proteínas do Nucleocapsídeo de Coronavírus/análise , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Estudos Transversais , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/genética , Estudos Soroepidemiológicos , Glicoproteína da Espícula de Coronavírus/análise , Glicoproteína da Espícula de Coronavírus/imunologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...