Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Zhejiang Da Xue Xue Bao Yi Xue Ban ; 46(1): 59-65, 2017 01 25.
Artigo em Chinês | MEDLINE | ID: mdl-28436632

RESUMO

Objective: To establish a fetal biparietal diameter (BPD)-gestational age formula based on the data of pregnant women from Xiaoshan District of Hangzhou, and to evaluate its application in prenatal screening. Methods: Data of 3500 pregnant women with gestational age between 15 weeks and 19 weeks+6 receiving prenatal screening in Xiaoshan Hospital during May 2014 and May 2015 were collected. BPDs were used to establish a localized BPD-gestational age formula. The localized formula was used to evaluate the prenatal screening risks in 1759 pregnant women with irregular menstrual cycles or uncertain last menstrual period (LMP) in Xiaoshan District, and the results were compared with those calculated using formula in LifeCycle 4.0. Results: With localized formula, the total positive rate of Down syndrome, trisomy 18 syndrome and deformity of neural tube was decreased from 6.96% to 5.85% ( P<0.05), in which the positive rate of Down syndrome decreased ( P<0.05), that of deformity of neural tube increased ( P<0.05), and that of trisomy 18 syndrome remained the same ( P>0.05). The median MoMs of free-hCG ß and α-fetoprotein calculated using localized formula were significantly different from those calculated using the formula in LifeCycle 4.0 (all P<0.05), and the former ones were more closer to 1. For women of fetus diagnosed with the above diseases, the positive rate calculated using localized formula was almost the same as that calculated using the formula in LifeCycle 4.0. Conclusion: BPD-gestational age formula should be localized based on the statistical analysis of the local population, which will help to reduce the false positive rate, and make the results more accurate and reliable in prenatal screening.


Assuntos
Pesos e Medidas Corporais/normas , Cefalometria/estatística & dados numéricos , Cefalometria/normas , Idade Gestacional , Cabeça/embriologia , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Diagnóstico Pré-Natal/estatística & dados numéricos , Diagnóstico Pré-Natal/normas , Adulto , Gonadotropina Coriônica Humana Subunidade beta/sangue , Gonadotropina Coriônica Humana Subunidade beta/normas , Cromossomos Humanos Par 18 , Síndrome de Down/diagnóstico , Síndrome de Down/embriologia , Medidas em Epidemiologia , Feminino , Desenvolvimento Fetal , Humanos , Programas de Rastreamento/estatística & dados numéricos , Ciclo Menstrual , Defeitos do Tubo Neural/diagnóstico , Defeitos do Tubo Neural/embriologia , Gravidez , Diagnóstico Pré-Natal/métodos , Valores de Referência , Trissomia/diagnóstico , Síndrome da Trissomía do Cromossomo 18 , alfa-Fetoproteínas/análise , alfa-Fetoproteínas/normas
2.
Clin Chim Acta ; 439: 61-7, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25283872

RESUMO

BACKGROUND: Beckman Coulter recently released the first commercially available hCG reagent calibrated against the 5th International Standard (IS) for hCG (total ßhCG (5th IS)). We performed a comprehensive analytical validation of this reagent. METHODS: Precision experiments were completed using 3 concentrations of commercial quality control material. Linearity, sample stability, and analytical sensitivity were evaluated using pools of human serum. Reportable range was assessed by comparing manual dilutions to those performed by the instrument. Male and female reference intervals were established using residual serum specimens submitted for routine testing. Inter-lot variability of hCG assay reagent was assessed by analyzing serum specimens with detectable hCG using 2 different reagent lots. Inter-assay variability was established using 203 serum specimens analyzed for hCG on 6 different reagent platforms. RESULTS: Inter-day precision showed a CV of <6.0% for all concentrations of QC material. LOB, LOD, and LOQ were determined to be 0.3, 0.4, and 0.6 U/l, respectively. The Access (5th IS) reagent has an average positive bias of approximately 20% when compared to most platforms and the previous generation Beckman hCG assay. Results were consistent between lots. Female reference intervals varied by age: <1.0 U/l (<41 y), <6.0 U/l (41-50 y), and <8.0 U/l (>50 y). Male reference intervals were <2.0 U/l. CONCLUSIONS: The analytical performance of the total ßhCG (5th IS) was established. Care should be taken to re-baseline patients needing serial monitoring and/or notify physicians when transitioning to the total ßhCG (5th IS) reagent.


Assuntos
Gonadotropina Coriônica Humana Subunidade beta/sangue , Imunoensaio , Adulto , Gonadotropina Coriônica Humana Subunidade beta/normas , Feminino , Humanos , Imunoensaio/normas , Masculino , Pessoa de Meia-Idade , Valores de Referência
5.
Clin Biochem ; 40(16-17): 1259-65, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17884034

RESUMO

OBJECTIVES: The principal objective of this study was to compare the analytical performance of the Elecsys2010 (Roche Diagnostics) system with the IMx (Abbott laboratories) system for beta-hCG assay in order to assess its possible utility as a confirmation test for the quantitative measurement of beta-hCG in urine for doping control purposes. DESIGN AND METHODS: Urine samples with spiked standard known concentrations of beta-hCG and different urine samples from athletes were used in order to determine the calibration curve stability and linearity, detection limit, total, within-run and between-run precision, and method comparison for the IMx and Elecsys2010 systems for beta-hCG assay, along with the stability of samples, at room temperature and at 4 degrees C. RESULTS: The IMx assay was linear up to 500 IU/L, whereas the Elecsys2010 assay was linear up to 1000 IU/L. The detection limit for the IMx and Elecsys2010 systems were 0.75 IU/L and 0.25 IU/L, respectively. The total precision of the IMx and Elecsys2010 systems were

Assuntos
Gonadotropina Coriônica Humana Subunidade beta/urina , Testes de Química Clínica/instrumentação , Dopagem Esportivo/prevenção & controle , Calibragem , Gonadotropina Coriônica Humana Subunidade beta/normas , Testes de Química Clínica/métodos , Humanos , Padrões de Referência , Análise de Regressão , Reprodutibilidade dos Testes
6.
J Immunol Methods ; 205(2): 169-75, 1997 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-9294599

RESUMO

Using time-resolved fluorometry, a simple one-step dual-label immunometric assay has been developed, which allows simultaneous determination of pregnancy-associated plasma protein A (PAPP-A) and free beta-subunit of human chorionic gonadotrophin (beta-hCG) in first-trimester maternal serum samples. Two monoclonal antibodies were biotinylated and immobilized onto the surface of streptavidin-coated microtitration plates, and used to capture PAPP-A and beta-hCG. respectively. Europium (Eu) and Samarium (Sm) chelates were conjugated to two additional monoclonal antibodies acting as detection antibodies for PAPP-A and beta-hCG. The assay was performed using a 4-h one-step format. The within-run precision with buffer-based calibrators was below 8% over the working range of PAPP-A (40-10000 mIU/l) and beta-hCG (7.3-525 micrograms/l) and no hook effect was observed. The intra- and inter-assay coefficients of variation were below 7.1% for serum samples. PAPP-A and beta-hCG concentrations measured by the dual assay in 39 first-trimester serum samples correlated excellently with those obtained by DELFIA single-label PAPP-A (r = 0.997) and the beta-hCG part (r = 0.993) of the DELFIA AFP/beta hCG dual-label assay.


Assuntos
Gonadotropina Coriônica Humana Subunidade beta/sangue , Fluorimunoensaio/métodos , Proteína Plasmática A Associada à Gravidez/análise , Gravidez/sangue , Anticorpos Monoclonais , Biotina , Gonadotropina Coriônica Humana Subunidade beta/imunologia , Gonadotropina Coriônica Humana Subunidade beta/normas , Estudos de Avaliação como Assunto , Feminino , Fluorimunoensaio/normas , Fluorimunoensaio/estatística & dados numéricos , Humanos , Cinética , Primeiro Trimestre da Gravidez , Proteína Plasmática A Associada à Gravidez/imunologia , Proteína Plasmática A Associada à Gravidez/normas , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS