Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Orthop Traumatol Turc ; 54(4): 461-464, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32554366

RESUMO

Delayed hypersensitivity reaction to metal ions is rare and has been mostly documented among patients undergoing total joint arthroplasty with metal-on-metal bearing surfaces. Nonetheless, to our knowledge, only a few cases associated with spinal arthrodesis have been reported in the literature. The aim of this case report was to describe the clinical features of a rare case of delayed-type hypersensitivity reaction to nickel that occurred after an extraordinarily long period of time (approximately 15 years) after spinal arthrodesis. Here, we present a 38-year-old patient who was referred to us with a diagnosis of delayed-type hypersensitivity reaction to nickel that was established by a skin patch test. The chief sign and symptoms of the patient were allergic contact dermatitis along with intractable, generalized itching that started several months ago. The medical history revealed that the patient had undergone spinal arthrodesis using rods and pedicle screws approximately 15 years ago, followed by revision surgery to remove the implants. Radiological examination showed a remnant pedicle screw fragment at the third lumbar vertebra that had broken off during the removal of implants nine years ago. However, the signs and symptoms of metal hypersensitivity started shortly before the patient was referred to our hospital. We decided to remove the screw fragment as allergic contact dermatitis was refractory to medical treatment. On postoperative day one, the itching was completely resolved, although the skin patch test remained positive.


Assuntos
Remoção de Dispositivo , Hipersensibilidade a Drogas , Corpos Estranhos , Hipersensibilidade Tardia , Níquel/efeitos adversos , Fusão Vertebral , Adulto , Hipersensibilidade a Drogas/etiologia , Hipersensibilidade a Drogas/cirurgia , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico , Corpos Estranhos/cirurgia , Humanos , Hipersensibilidade Tardia/induzido quimicamente , Hipersensibilidade Tardia/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Metais/efeitos adversos , Parafusos Pediculares/efeitos adversos , Radiografia/métodos , Reoperação/métodos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Resultado do Tratamento
2.
Ocul Immunol Inflamm ; 26(6): 910-914, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28471252

RESUMO

PURPOSE: Complications associated with gold-weight insertion for lagophthalmos are uncommon, recent reports have provided evidence to suggest that type IV hypersensitivity to gold can cause a persistent inflammatory reaction. METHODS: We present a case of a 46-year-old man who experienced persistent post-operative inflammation, and summarize previously documented cases. This patient underwent uncomplicated insertion of an upper eyelid gold weight for right-sided facial nerve palsy. He had no allergies or implanted metalwork. Post-operatively erythema was noted at seven-weeks and did not resolve. The weight was removed after six-months. RESULTS: The histopathological findings were in keeping with type IV hypersensitivity and similar to previous cases. CONCLUSIONS: Although infrequent, this complication has poor outcomes. The definitive management is removal of the weight. Information regarding implanted gold, and previous reactions should be elicited pre-operatively. Type IV hypersensitivity should be considered in patients with persistent inflammation that do not respond to antibiotic or steroid therapy.


Assuntos
Blefaroplastia/efeitos adversos , Remoção de Dispositivo/métodos , Doenças Palpebrais/cirurgia , Pálpebras/cirurgia , Ouro/efeitos adversos , Hipersensibilidade Tardia/induzido quimicamente , Complicações Pós-Operatórias/induzido quimicamente , Próteses e Implantes/efeitos adversos , Doenças Palpebrais/diagnóstico , Pálpebras/diagnóstico por imagem , Humanos , Hipersensibilidade Tardia/diagnóstico , Hipersensibilidade Tardia/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/cirurgia , Reoperação
4.
J Long Term Eff Med Implants ; 24(1): 25-36, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24941403

RESUMO

Metal hypersensitivity has been an identified problem in orthopedics for nearly half a century, but its implications remain unclear. Establishing which total joint arthroplasty (TJA) candidates may do poorly with conventional implants and which patients would benefit from revision to an allergen-free implant remains challenging. Our systematic search of the MEDLINE database identified 52 articles for inclusion in our review. Case reports revealed that half of patients presented with pain and swelling, while only one-third presented with cutaneous symptoms. All patients were symptomatic within the first post-operative year; 90% were symptomatic within 3 months. Reports of patch testing revealed that patients with TJAs were positive for metal sensitivity more often than patients without TJAs (OR 1.3). Those with poorly functioning arthroplasties and those who had already had revisions tested positive more often than those with well-functioning TJAs (OR 1.7) and those without TJAs (OR 3.1). Lymphocyte transformation testing (LTT) shows promise in diagnosing metal allergy, and components of bone cement are also being recognized as potential allergens. Further work is necessary to delineate which patients should be tested for metal allergy and which patients would benefit from allergen-free implants.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Hipersensibilidade Tardia/diagnóstico , Hipersensibilidade Tardia/cirurgia , Próteses Articulares Metal-Metal/efeitos adversos , Metais/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Cimentos Ósseos/efeitos adversos , Humanos , Hipersensibilidade Tardia/etiologia , Ativação Linfocitária , Metais/imunologia , Testes do Emplastro , Seleção de Pacientes , Reoperação
5.
Scand J Immunol ; 77(4): 238-45, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23421583

RESUMO

The repeated application of antigens results in the induction of tolerance. Lymph nodes are responsible for this reaction by producing suppressor cells. Using an in vivo transplantation model, we showed recently that stromal cells from different lymph nodes induce different cell populations for suppression, which all produce a tolerogenic phenotype. In this study, we were interested in the role of the spleen in these tolerance reactions. Therefore, tolerance was induced via feeding or injecting ovalbumin several times in control and splenectomized mice. The delayed-type hypersensitivity (DTH) was measured as well as the cell subset composition of the spleen. The spleen of peripherally tolerized mice showed higher proliferation activity and a specific antibody production compared with orally tolerized mice, where regulatory T cells were predominantly found. Tolerance induction after removal of the spleen resulted in a reduced DTH response in antigen fed animals, whereas skin tolerance induction failed. In conclusion, the results illustrate that lymph nodes from different areas employ their individual pathways for similar immune reactions, and the spleen is part of this reaction initiated at the peripheral site.


Assuntos
Tolerância Imunológica , Pele/imunologia , Baço/imunologia , Administração Oral , Animais , Antígenos/administração & dosagem , Antígenos/imunologia , Linfócitos B/imunologia , Feminino , Hipersensibilidade Tardia/imunologia , Hipersensibilidade Tardia/cirurgia , Intestinos/imunologia , Linfonodos/imunologia , Ativação Linfocitária/imunologia , Camundongos , Ovalbumina/imunologia , Baço/cirurgia , Esplenectomia
6.
J Plast Reconstr Aesthet Surg ; 65(7): 969-72, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22236477

RESUMO

We present a case of hypersensitivity to a breast implant in a 57-year old female with breast cancer and hypersensitivity to adhesive dressings. A mastectomy, axillary node clearance, latissimus dorsi flap and silicone implant-based reconstruction were performed. The mammary wound dehisced within three weeks and the implant required removal. No pus was present, and cultures were negative. Three years later, a further silicone implant was inserted. Within three weeks from insertion, the patient required readmission with serous discharge from the wound, flu-like symptoms, low-grade pyrexia and painful swelling at the operative site. The implant was removed. Capsule biopsies demonstrated a large lymphoid cell reaction, in keeping with a delayed hypersensitivity reaction. Patch testing to samples of the implant was positive.


Assuntos
Implantes de Mama/efeitos adversos , Hipersensibilidade Tardia/etiologia , Hipersensibilidade Tardia/cirurgia , Silicones/efeitos adversos , Neoplasias da Mama/cirurgia , Remoção de Dispositivo , Feminino , Humanos , Mamoplastia/métodos , Mastectomia , Pessoa de Meia-Idade , Retalhos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS