Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
Mol Genet Metab ; 134(3): 223-234, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34649782

RESUMO

INTRODUCTION: Early recognized manifestations of GSD III include hypoglycemia, hepatomegaly, and elevated liver enzymes. Motor symptoms such as fatigue, muscle weakness, functional impairments, and muscle wasting are typically reported in the 3rd to 4th decade of life. OBJECTIVE: In this study, we investigated the early musculoskeletal findings in children with GSD IIIa, compared to a cohort of adults with GSD IIIa. METHODS: We utilized a comprehensive number of physical therapy outcome measures to cross-sectionally assess strength and gross motor function including the modified Medical Research Council (mMRC) scale, grip and lateral/key pinch, Gross Motor Function Measure (GMFM), Gait, Stairs, Gowers, Chair (GSGC) test, 6 Minute Walk Test (6MWT), and Bruininks-Oseretsky Test of Motor Proficiency Ed. 2 (BOT-2). We also assessed laboratory biomarkers (AST, ALT, CK and urine Glc4) and conducted whole-body magnetic resonance imaging (WBMRI) to evaluate for proton density fat fraction (PDFF) in children with GSD IIIa. Nerve Conduction Studies and Electromyography results were analyzed where available and a thorough literature review was conducted. RESULTS: There were a total of 22 individuals with GSD IIIa evaluated in our study, 17 pediatric patients and 5 adult patients. These pediatric patients demonstrated weakness on manual muscle testing, decreased grip and lateral/key pinch strength, and decreased functional ability compared to non-disease peers on the GMFM, 6MWT, BOT-2, and GSGC. Additionally, all laboratory biomarkers analyzed and PDFF obtained from WBMRI were increased in comparison to non-diseased peers. In comparison to the pediatric cohort, adults demonstrated worse overall performance on functional assessments demonstrating the expected progression of disease phenotype with age. CONCLUSION: These results demonstrate the presence of early musculoskeletal involvement in children with GSD IIIa, most evident on physical therapy assessments, in addition to the more commonly reported hepatic symptoms. Muscular weakness in both children and adults was most significant in proximal and trunk musculature, and intrinsic musculature of the hands. These findings indicate the importance of early assessment of patients with GSD IIIa for detection of muscular weakness and development of treatment approaches that target both the liver and muscle.


Assuntos
Doença de Depósito de Glicogênio Tipo III/diagnóstico por imagem , Imageamento por Ressonância Magnética/estatística & dados numéricos , Modalidades de Fisioterapia/normas , Imagem Corporal Total/estatística & dados numéricos , Adolescente , Adulto , Criança , Pré-Escolar , Estudos de Coortes , Estudos Transversais , Feminino , Humanos , Lactente , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Debilidade Muscular/patologia , Músculo Esquelético/patologia , Imagem Corporal Total/normas , Adulto Jovem
2.
Artigo em Inglês | MEDLINE | ID: mdl-34218886

RESUMO

The goal of developing a PET dedicated to the brain (CareMiBrain) has evolved from its initial approach to diagnosis and monitoring of dementias, to the more ambitious of creating a revolutionary clinical pathway for the knowledge and personalized treatment of multiple neurological diseases. The main innovative feature of CareMiBrain is the use of detectors with continuous crystals, which allow a high resolution determination of the depth of annihilation photons interaction within the thickness of the scintillation crystal. The technical validation phase of the equipment consisted of a pilot, prospective and observational study whose objective was to obtain the first images (40 patients), analyze them and make adjustments in the acquisition, reconstruction and correction parameters, comparing the image quality of the CareMiBrain equipment with that of the whole-body PET/CT. Thanks to the team meetings and the joint analysis of the images, it was possible to detect its weak points and some of its causes. The calibration, acquisition and processing processes, as well as the reconstruction, were optimized, the number of iterations was set to achieve the best signal-to-noise ratio, the random correction was optimized and a post-processing algorithm was included in the reconstruction algorithm. The main technical improvements implemented in this phase of technical validation carried out through collaboration of the Services of Nuclear Medicine and Neurology of the Hospital Clínico San Carlos with the Spanish company Oncovision will be exposed in a project financed with funds from the European Union (Horizon 2020 innovation program, 713323).


Assuntos
Encéfalo/diagnóstico por imagem , Doenças Neurodegenerativas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Melhoria de Qualidade , Adulto , Calibragem , Demência/diagnóstico por imagem , Desenho de Equipamento , Humanos , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/normas , Estudos Prospectivos , Razão Sinal-Ruído , Imagem Corporal Total/métodos , Imagem Corporal Total/normas
3.
Medicine (Baltimore) ; 100(2): e24205, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-33466198

RESUMO

OBJECTIVES: Controversies emerge over routine performances of whole-body computed tomography (WBCT) in patients with blunt polytrauma. The existing randomized and non-randomized evidence is inconclusive, and during observations of non-trauma, incidental findings, detected by WBCT, have left uncertainty regarding their consequences and optimal management. Additionally, previous meta-analyses have failed to address the limitations of primary studies and issues associated with incidental findings. Therefore, we planned a new systematic review to address these points. METHODS: We will search the PubMed, EMBASE, and Cochrane Central databases from inception to December 31, 2020, with no language restriction and perform full-text evaluation of potentially relevant articles. We will include prospective and retrospective studies with a single-gate design that assessed diagnostic accuracy and/or yield of WBCT to detect traumatic injuries, and studies that assessed incidental findings detected by WBCT. Additionally, we will include randomized controlled trials and non-randomized comparative studies that assessed the effectiveness of WBCT against conventional care, including selective computed tomography (CT). Studies of patients of all ages with blunt traumatic injuries, assessed at an emergency department, will be included. Two reviewers will extract data and rate the study validity via standard quality assessment tools. The primary outcome of interest will be reduction in mortality. Our secondary outcomes will include diagnostic accuracy and yield, detection of incidental findings and clinical outcomes associated with these detections, and improvement in other non-mortality clinical outcomes. We will qualitatively assess study, patient, and intervention characteristics and clinical outcomes. If appropriate, we will perform random-effects model meta-analyses to obtain summary estimates. Finally, we will assess the certainty of evidence by the grading the quality of evidence and strength of recommendations. ETHICS AND DISSEMINATION: Ethics approval is not applicable, as this is a secondary analysis of publicly available data. The review results will be submitted for publication in peer-reviewed journals. PROSPERO REGISTRATION: CRD42020187852.


Assuntos
Protocolos Clínicos , Imagem Corporal Total/normas , Ferimentos não Penetrantes/diagnóstico por imagem , Humanos , Metanálise como Assunto , Sensibilidade e Especificidade , Revisões Sistemáticas como Assunto , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Imagem Corporal Total/métodos
6.
Cancer Imaging ; 20(1): 77, 2020 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-33109268

RESUMO

BACKGROUND: The METastasis Reporting and Data System for Prostate Cancer (MET-RADS-P) guidelines are designed to enable reproducible assessment in detecting and quantifying metastatic disease response using whole-body magnetic resonance imaging (WB-MRI) in patients with advanced prostate cancer (APC). The purpose of our study was to evaluate the inter-observer agreement of WB-MRI examination reports produced by readers of different expertise when using the MET-RADS-P guidelines. METHODS: Fifty consecutive paired WB-MRI examinations, performed from December 2016 to February 2018 on 31 patients, were retrospectively examined to compare reports by a Senior Radiologist (9 years of experience in WB-MRI) and Resident Radiologist (after a 6-months training) using MET-RADS-P guidelines, for detection and for primary/dominant and secondary response assessment categories (RAC) scores assigned to metastatic disease in 14 body regions. Inter-observer agreement regarding RAC score was evaluated for each region by using weighted-Cohen's Kappa statistics (K). RESULTS: The number of metastatic regions reported by the Senior Radiologist (249) and Resident Radiologist (251) was comparable. For the primary/dominant RAC pattern, the agreement between readers was excellent for the metastatic findings in cervical, dorsal, and lumbosacral spine, pelvis, limbs, lungs and other sites (K:0.81-1.0), substantial for thorax, retroperitoneal nodes, other nodes and liver (K:0.61-0.80), moderate for pelvic nodes (K:0.56), fair for primary soft tissue and not assessable for skull due to the absence of findings. For the secondary RAC pattern, agreement between readers was excellent for the metastatic findings in cervical spine (K:0.93) and retroperitoneal nodes (K:0.89), substantial for those in dorsal spine, pelvis, thorax, limbs and pelvic nodes (K:0.61-0.80), and moderate for lumbosacral spine (K:0.44). CONCLUSIONS: We found inter-observer agreement between two readers of different expertise levels to be excellent in bone, but mixed in other body regions. Considering the importance of bone metastases in patients with APC, our results favor the use of MET-RADS-P in response to the growing clinical need for monitoring of metastasis in these patients.


Assuntos
Sistemas de Dados , Imageamento por Ressonância Magnética/normas , Neoplasias da Próstata/diagnóstico por imagem , Projetos de Pesquisa/normas , Idoso , Prova Pericial , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Guias de Prática Clínica como Assunto , Radiologistas/normas , Imagem Corporal Total/métodos , Imagem Corporal Total/normas
7.
Ann Hematol ; 99(12): 2869-2880, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32951093

RESUMO

Magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose positron emission tomography-computed tomography (18FDG 18F-FDG PET-CT) are standard procedures for staging multiple myeloma (MM). Diffusion-weighted sequences applied to whole-body MRI (WB-DWI) improve its sensitivity. We compared the number of MM bone focal lesions (FLs) detected by 18F-FDG PET-CT and WB-DWI and evaluated the diagnostic performance of 18F-FDG PET-CT for diffuse infiltration. Thirty newly diagnosed MM patients prospectively underwent 18F-FDG PET-CT and WB-DWI. The criteria for skeletal region positivity were ≥ 1 focal bone lesions (FLs) and/or diffuse disease. MRI with the MY-RADS criteria was used as a reference standard for the diagnosis of diffuse infiltration. 18F-FDG PET-CT and WB-DWI were both interpreted as positive in 28/30 patients with an agreement of 1.00 (95% CI 0.77-1.00) between the two methods. The mean numbers of FLs were 16.7 detected by 18F-FDG PET-CT and 23.9 detected by WB-DWI (P = 0.028). WB-DWI detected more FLs in the skull (P = 0.001) and spine (P = 0.006). Agreement assessed using the prevalence and bias-corrected kappa index was moderate (0.40-0.60) for the spine, sternum-ribs and upper limbs and substantial (0.60-0.80) for the pelvis and lower limbs. As regards the diagnosis of diffuse bone marrow infiltration, the sensitivity, specificity and accuracy of 18F-FDG PET-CT were 0.75, 0.79 and 0.77, respectively. Although WB-DWI detected more FLs than did 18F-FDG PET-CT, there was no difference in the detection of bone disease on a per-patient basis. 18F-FDG PET-CT showed high performance, including for evaluation of diffuse infiltration.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Fluordesoxiglucose F18 , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Imagem Corporal Total/métodos , Adulto , Idoso , Imagem de Difusão por Ressonância Magnética/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Estudos Prospectivos , Imagem Corporal Total/normas
8.
Horm Metab Res ; 52(12): 834-840, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32750721

RESUMO

Initial treatment for differentiated thyroid carcinoma (DTC) often consists of surgery and the administration of radioiodine. In this context, post-treatment Whole-Body Scans (ptWBS) are currently recommended, but data on its diagnostic accuracy are rare. The aim of the study was to evaluate the performance of ptWBS for distant metastasis in DTC patients. We included DTC patients who received radioiodine and underwent ptWBS between 2009-2015. The medical data were independently reviewed by two specialists to evaluate the concordance of positive distant ptWBS uptake and distant metastasis documented by imaging exams (gold standard). We studied 268 DTC patients. The mean age was 46±16 years (82% women), and papillary thyroid carcinoma was diagnosed in 87% of the patients. The median tumor size was 2.7 cm, 40% had lymph node involvement, and 11% had distant metastasis. Twenty-eight patients (10%) had distant ptWBS uptake, and nine of them (32%) were false-positives. In addition, nine false-negative ptWBS uptakes were identified. The overall performance of ptWBS showed 68% sensitivity and 96% specificity with significantly different performance according to the American Thyroid Association (ATA) risk groups. While the ptWBS performance for ATA low-intermediate-risk showed 29% sensitivity, 97% specificity, and Kappa of 0.19, the ATA high-risk group ptWBS displayed high sensitivity (82%), specificity (100%), and good agreement (Kappa 0.74). ptWBS is useful for a subgroup of ATA high-risk DTC patients. The overall poor performance of ptWBS suggests that it should be reconsidered for routine use in ATA at low to intermediate risk: the exam has little value to this subgroup.


Assuntos
Adenocarcinoma Folicular/secundário , Câncer Papilífero da Tireoide/secundário , Neoplasias da Glândula Tireoide/patologia , Tireoidectomia/métodos , Imagem Corporal Total/métodos , Imagem Corporal Total/normas , Adenocarcinoma Folicular/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Câncer Papilífero da Tireoide/cirurgia , Neoplasias da Glândula Tireoide/cirurgia
9.
Cancer Imaging ; 20(1): 48, 2020 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-32665028

RESUMO

BACKGROUND: Whole body magnetic resonance imaging (MRI) is now incorporated into international guidance for imaging patients with multiple myeloma. The aim of this study was to investigate inter-observer agreement of triple reported baseline whole-body MRI in myeloma and highlight potential pitfalls. METHODS: Fifty-seven patients with symptomatic myeloma at first presentation or relapse and planned for autologous stem cell transplant were included. All patients completed baseline whole body MRI within 2 weeks prior to starting treatment. Each scan was reported independently by 3 radiologists using a defined scoring system. Differences in observer scores were compared using analysis of variance (ANOVA) and inter-observer agreement assessed using intra class correlation coefficient (ICC). RESULTS: There was no significant difference in mean observer scores for whole skeleton and ICC demonstrated excellent inter-observer agreement at 0.91. ICC varied between skeletal regions with spine, pelvis and ribs showing good inter-observer agreement, whereas skull and long bones were moderate. Scans with variation in observer scores were re-examined and cause of discrepancies identified. This information was used to describe potential anatomical pitfalls in reporting . CONCLUSION: Whole-body MRI has excellent inter-observer agreement in reporting symptomatic myeloma at baseline. Inter-observer agreement varied between skeletal regions highlighting specific areas of difficulty.


Assuntos
Imageamento por Ressonância Magnética/normas , Mieloma Múltiplo/diagnóstico por imagem , Imagem Corporal Total/normas , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Imagem Corporal Total/métodos
10.
In Vivo ; 33(6): 2255-2263, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31662565

RESUMO

BACKGROUND/AIM: The aim of the study was to prospectively compare I-131 postablation Whole Body scan (WBS) and Single Photon Emission Computerized Tomography/Computerized Tomography (SPECT/CT) scan on thyroid cancer patients. PATIENTS AND METHODS: Overall, 58 patients with papillary thyroid carcinoma were submitted to total thyroidectomy and I-131 remnant ablation. Post-ablation WBS and SPECT/CT scans performed on the same day were compared. Results of SPECT/CT were confirmed by neck and upper mediastinum ultrasound scan and on specific cases by a fully diagnostic CT scan, other tests and definitive histology acting as the gold standard. A total of 36/58 patients were followed-up for 5 years to detect relapse. RESULTS: Mac Nemar Chi square and Fisher's exact tests disclosed statistically significant differences between WBS and SPECT/CT scan, concerning cervical lymphadenopathy detection (p=0.031) and relapse prediction by NM stage (p=0.033), respectively; SPECT/CT was more accurate in both comparisons. CONCLUSION: In papillary thyroid carcinoma I-131 post-ablation SPECT/CT scan detects cervical lymphadenopathy and predicts relapse by NM stage more accurately than WBS.


Assuntos
Radioisótopos do Iodo , Câncer Papilífero da Tireoide/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Imagem Corporal Total , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sensibilidade e Especificidade , Câncer Papilífero da Tireoide/terapia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único/normas , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Imagem Corporal Total/métodos , Imagem Corporal Total/normas
11.
Phys Med Biol ; 64(20): 205013, 2019 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-31631886

RESUMO

Image quality in positron emission tomography (PET) is limited by the number of detected photons. Heavier patients present higher photon attenuation levels, thus increasing image noise. In this work, we propose a new method that uses the combined patient attenuation/system matrix together with a tracer uptake prediction model to optimize scan times for different bed positions in whole body scans. Our main goal is to achieve consistent noise levels across patients and anatomical regions. We propose to optimize scan times for individual bed positions, for patients of any size, based on the scanner sensitivity and patient-specific attenuation. Variable scan times for every bed position were determined by combining the system matrix, derived from the computed tomography (CT) and the scanner-specific geometric sensitivity profiles, and estimations of the global tracer uptake for each patient. The method was validated with anthropomorphic phantoms and whole-body patient 18F-FDG PET/CT scans, where variable and fixed times were compared. Phantom experiments showed that the proposed method was successful in keeping noise level constant for different attenuation setups. In real patients, image noise variability was reduced to less than one-half compared with conventional fixed-time scans at the expense of a four-fold increase in scan times between the biggest and smallest patients. Our method can homogenize image quality not only across patients of different sizes but also across different bed positions of the same patient.


Assuntos
Modelagem Computacional Específica para o Paciente , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Imagem Corporal Total/métodos , Fluordesoxiglucose F18 , Humanos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Compostos Radiofarmacêuticos , Razão Sinal-Ruído , Tempo , Imagem Corporal Total/normas
12.
Injury ; 50(9): 1511-1515, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31399208

RESUMO

BACKGROUND: Increasing global demand for specialized radiological investigations has resulted in delayed or non-reporting of plain trauma radiographs by radiologists. This is particularly true in resource-limited environments, where referring clinicians rely largely on their own radiographic interpretation. A wide accuracy range has been documented for non-radiologist reporting of conventional trauma radiographs. The Lodox Statscan whole-body digital X-ray machine is a relatively new technology that poses unique interpretive challenges. The fracture detection rate of trauma clinicians utilizing this modality has not been determined. OBJECTIVE: An audit of the polytrauma fracture detection rate of clinicians evaluating Lodox Statscan bodygrams in two South African public-sector Trauma Units. METHODS: A retrospective descriptive study of imaging data of Cape Town Level 1-equivalent public-sector Trauma Units during March-April 2015. Statscan bodygrams acquired for adult polytrauma triage were reviewed and correlated with follow-up imaging and patient records. Missed fractures were stratified by body part, mechanism of injury and ventilatory support. The fracture detection rate was determined with 95% confidence. The Generalised Fischer Exact Test assessed any association between the fracture site and failure of detection. Specialist orthopaedic review assessed the potential need for surgical management of missed fractures. RESULTS: 227 patients (male = 193, 85%; mean age: 33 years) were included; 195 fractures were demonstrated on the whole-body triage projections. Lower limb fractures predominated (n = 66, 34%). The fracture detection rate was 89% (95% CI = 86-93%), with the site of fracture associated with failure of detection (p = 0.01). Twelve of 21 undetected fractures (57%) involved the elbow or shoulder girdle. All elbow fractures (n = 3, 100%), more than half the shoulder girdle fractures (9/13,69%) and 12% (15/123) of extremity fractures were undetected. One missed fracture (1/21,4.7%) unequivocally required surgical management, while a further 7 (7/21, 33.3%) could potentially have benefitted from surgery, depending on follow-up imaging findings. CONCLUSION: This is the first analysis of the accuracy of bodygram polytrauma fracture detection by clinicians. Particular review of the shoulder girdle, elbow and extremities for subtle fractures, in addition to standardized limb positioning, are recommended for improved diagnostic accuracy in this setting. These findings can inform clinician training courses in this domain.


Assuntos
Erros de Diagnóstico/estatística & dados numéricos , Fraturas Ósseas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/estatística & dados numéricos , Traumatismo Múltiplo/diagnóstico por imagem , Intensificação de Imagem Radiográfica/normas , Centros de Traumatologia/economia , Imagem Corporal Total/normas , Adulto , Auditoria Clínica , Competência Clínica , Erros de Diagnóstico/economia , Feminino , Fraturas Ósseas/economia , Humanos , Masculino , Traumatismo Múltiplo/economia , Valor Preditivo dos Testes , Setor Público , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , África do Sul/epidemiologia , Tecnologia Radiológica/instrumentação , Tomografia Computadorizada por Raios X , Centros de Traumatologia/normas , Triagem , Imagem Corporal Total/economia
13.
Lancet Gastroenterol Hepatol ; 4(7): 529-537, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31080095

RESUMO

BACKGROUND: Whole-body MRI (WB-MRI) could be an alternative to multimodality staging of colorectal cancer, but its diagnostic accuracy, effect on staging times, number of tests needed, cost, and effect on treatment decisions are unknown. We aimed to prospectively compare the diagnostic accuracy and efficiency of WB-MRI-based staging pathways with standard pathways in colorectal cancer. METHODS: The Streamline C trial was a prospective, multicentre trial done in 16 hospitals in England. Eligible patients were 18 years or older, with newly diagnosed colorectal cancer. Exclusion criteria were severe systemic disease, pregnancy, contraindications to MRI, or polyp cancer. Patients underwent WB-MRI, the result of which was withheld until standard staging investigations were complete and the first treatment decision made. The multidisciplinary team recorded its treatment decision based on standard investigations, then on the WB-MRI staging pathway (WB-MRI plus additional tests generated), and finally on all tests. The primary outcome was difference in per-patient sensitivity for metastases between standard and WB-MRI staging pathways against a consensus reference standard at 12 months, in the per-protocol population. Secondary outcomes were difference in per-patient specificity for metastatic disease detection between standard and WB-MRI staging pathways, differences in treatment decisions, staging efficiency (time taken, test number, and costs), and per-organ sensitivity and specificity for metastases and per-patient agreement for local T and N stage. This trial is registered with the International Standard Randomised Controlled Trial registry, number ISRCTN43958015, and is complete. FINDINGS: Between March 26, 2013, and Aug 19, 2016, 1020 patients were screened for eligibility. 370 patients were recruited, 299 of whom completed the trial; 68 (23%) had metastasis at baseline. Pathway sensitivity was 67% (95% CI 56 to 78) for WB-MRI and 63% (51 to 74) for standard pathways, a difference in sensitivity of 4% (-5 to 13, p=0·51). No adverse events related to imaging were reported. Specificity did not differ between WB-MRI (95% [95% CI 92-97]) and standard pathways (93% [90-96], p=0·48). Agreement with the multidisciplinary team's final treatment decision was 96% for WB-MRI and 95% for the standard pathway. Time to complete staging was shorter for WB-MRI (median, 8 days [IQR 6-9]) than for the standard pathway (13 days [11-15]); a 5-day (3-7) difference. WB-MRI required fewer tests (median, one [95% CI 1 to 1]) than did standard pathways (two [2 to 2]), a difference of one (1 to 1). Mean per-patient staging costs were £216 (95% CI 211-221) for WB-MRI and £285 (260-310) for standard pathways. INTERPRETATION: WB-MRI staging pathways have similar accuracy to standard pathways and reduce the number of tests needed, staging time, and cost. FUNDING: UK National Institute for Health Research.


Assuntos
Neoplasias Colorretais/patologia , Imageamento por Ressonância Magnética/normas , Imagem Corporal Total/normas , Idoso , Procedimentos Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Estadiamento de Neoplasias , Estudos Prospectivos , Padrões de Referência , Sensibilidade e Especificidade
14.
Nuklearmedizin ; 58(3): 228-241, 2019 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-31035298

RESUMO

Version 5 of the procedural guideline for Iodine-131 whole-body scintigraphy (WBS) in differentiated thyroid carcinoma is an update of the version 4, published by the "Deutsche Gesellschaft für Nuklearmedizin" (DGN). This procedural guideline advises on how to best perform I-131 whole body scintigraphy after I-131 therapy or after application of a diagnostic I-131 activity. A representative expert group has discussed and reached consensus on the procedural guideline; the development of this procedural guideline therefore fulfils the criteria for level S1 (first step) within the classification of the German Workgroup of Scientific Medical Societies ("Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften"; AWMF).


Assuntos
Carcinoma/radioterapia , Radioisótopos do Iodo/uso terapêutico , Cintilografia/normas , Neoplasias da Glândula Tireoide/radioterapia , Imagem Corporal Total/normas , Carcinoma/diagnóstico por imagem , Carcinoma/patologia , Medicina Baseada em Evidências , Humanos , Sociedades Médicas , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia
15.
Rofo ; 191(11): 1015-1025, 2019 Nov.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-30999381

RESUMO

PURPOSE: Evaluation of the dose values of a polytrauma whole-body CT examination used in clinical practice with regard to the 2016 updated diagnostic reference levels and reduction of the mean exposure levels using simple optimization steps. MATERIALS AND METHODS: In each case, 100 exposure values before and after dose optimization were compared with the old and new diagnostic reference levels. The grayscale values and the signal-to-noise ratio (SNR) were determined for the lung, the aortic arch and the liver. A visual assessment of the image quality was performed by two radiologists on the basis of a Likert scale (0 - non-diagnostic, 1 - poor visualization, 2 - moderate visualization, 3 - good visualization, 4 - excellent visualization) for CT examinations both before and after optimization. RESULTS: The acquired exposure values after dose optimization were below the old and new diagnostic reference levels (1319.98 ±â€Š463.16 mGy ·â€Šcm) while the mean value of the exposure values before optimization (1774.96 ±â€Š608.78 mGy ·â€Šcm) exceeded the current diagnostic reference levels. The measured grayscale values (HU) were (before versus after optimization): lung - 833 HU vs. - 827 HU (p = 0.43), aortic arch 341 HU vs. 343 HU (p = 0.70) and liver 68 HU vs. 67 HU (p = 0.35). After dose optimization the SNR in the lung was minimally higher, while it was minimally lower in the two other regions than before the optimization. Visual assessment of the image quality showed almost identical values with 3.85 evaluation points before and 3.82 evaluation points after dose optimization (p = 0.57). CONCLUSION: Due to the updating of the diagnostic reference levels, an analysis of the own exposure values is necessary in order to be able to detect high values promptly and to initiate appropriate measures for dose reduction. Appropriate adaptation of the examination parameters with consideration of the necessary image quality allows a significant reduction of the radiation exposure in most cases, also on CT devices of older generations. KEY POINTS: · In many cases a dose reduction below the DRLs is already possible by optimizing the examination technique.. · In order to ensure a diagnostic image quality, the control of the image quality is unavoidable in a dose reduction.. · Through suitable parameter adjustments a compliance with the DRLs is also possible, using CT devices of older generation without iterative image reconstruction.. CITATION FORMAT: · Schäfer SB, Rudolph C, Kolodziej M et al. Optimization of Whole-Body CT Examinations of Polytrauma Patients in Comparison with the Current Diagnostic Reference Levels. Fortschr Röntgenstr 2019; 191: 1015 - 1025.


Assuntos
Traumatismo Múltiplo/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Adulto , Aorta Torácica/efeitos da radiação , Feminino , Alemanha , Humanos , Aumento da Imagem/métodos , Aumento da Imagem/normas , Fígado/efeitos da radiação , Pulmão/efeitos da radiação , Masculino , Doses de Radiação , Exposição à Radiação/prevenção & controle , Exposição à Radiação/normas , Valores de Referência , Tomografia Computadorizada por Raios X/normas , Imagem Corporal Total/normas
16.
Rofo ; 191(4): 289-297, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30818411

RESUMO

Combined PET/MR imaging (PET/MRI) was proposed for patient management in 2006 with first commercial versions of integrated whole-body systems becoming available as of 2010. PET/MRI followed the prior evolution of hybrid imaging as attested by the successful adoption of combined PET/CT and SPECT/CT since the early 2000 s. Today, around 150 whole-body PET/MRI systems have become operational worldwide. One of the main application fields of PET/MRI is oncologic imaging. Despite the increasing use of PET/MRI, little governance regarding standardized PET/MRI protocols has been provided to date. Standardization and harmonization of imaging protocols is, however, mandatory for efficient on-site patient management and multi-center studies. This document summarizes consensus recommendations on key aspects of patient referral and preparation, PET/MRI workflow and imaging protocols, as well as reporting strategies for whole-body [18F]-FDG-PET/MRI. These recommendations were created by early adopters and key experts in the field of PET, MRI and PET/MRI. This document is intended to provide guidance for the harmonization and standardization of PET/MRI today and to support wider clinical adoption of this imaging modality for the benefit of patients. CITATION FORMAT: · Umutlu L, Beyer T, Grueneisen JS et al. Whole-Body [18F]-FDG-PET/MRI for Oncology: A Consensus Recommendation. Fortschr Röntgenstr 2019; 191: 289 - 297.


Assuntos
Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total/métodos , Artefatos , Humanos , Imageamento por Ressonância Magnética/normas , Educação de Pacientes como Assunto/métodos , Tomografia por Emissão de Pósitrons/normas , Controle de Qualidade , Sistemas de Informação em Radiologia , Imagem Corporal Total/normas , Fluxo de Trabalho
17.
Artigo em Inglês | MEDLINE | ID: mdl-30808035

RESUMO

OBJECTIVE: The present study evaluated whole-body radiographs of female rabbits regarding uterine disorders. MATERIAL AND METHODS: Based on radiographs of 143 rabbits, visibility, size, shape and density of the uterus, nutritional status of the animal and possible metastasis in other organs were examined. A suspected diagnosis was deduced. The radiological findings were compared with the results of the histopathological examination. RESULTS: Especially the nutritional status was important regarding the visibility of the genital tract. In 99 of the 130 visible uteri (76.2 %), a pathological alteration was detected. Thereof, endometrial hyperplasia was most frequently seen (63.6 %), followed by neoplasia (altogether 42.4 %, 39.4 % of these with adenocarcinoma), endometritis (35.4 %) and other diseases (18.2 %). Forty-six rabbits showed only one disease, 42 rabbits had two, 10 rabbits three and one rabbit four different diseases. Among 13 of the 143 uteri that were not visible in the radiograph four were altered pathologically. In 31 of the 130 rabbits with a visible uterine region (21.7 %) the uterus was unaltered. Visualising the uterus proved impossible in two of four skinny rabbits (2.8 %), whereas in all 39 obese rabbits the uterus was visible. Only in one of the four skinny rabbits was the uterus without pathological findings and six of the 39 obese rabbits showed no pathological alteration, visibility notwithstanding. Calcification indicated a tumourous occurrence in 23 of 53 cases. Except for one rabbit, the mineralised neoplasia was an adenocarcinoma (n = 22). Five animals with calcification in the uterine region showed no abnormalities. Of these, the calcification of four animals was no longer existent in the radiograph after ovariohysterectomy. Neoplastic changes in the uterus did not always show calcification. In 20 of the 44 patients with uterine neoplasia no calcification was seen. Changes in uterine size occurred in 118 of the 143 rabbits (82.5 %) and alteration of the uterine shape in 109 of the 143 rabbits (67.1 %). CONCLUSION AND CLINICAL RELEVANCE: Thus, the above presented parameters - especially size, shape and mineralisation - are very important regarding uterine diseases.


Assuntos
Coelhos , Doenças Uterinas/veterinária , Imagem Corporal Total/veterinária , Animais , Feminino , Reprodutibilidade dos Testes , Doenças Uterinas/diagnóstico por imagem , Útero/diagnóstico por imagem , Imagem Corporal Total/métodos , Imagem Corporal Total/normas
18.
J Med Imaging Radiat Oncol ; 63(3): 291-299, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30770654

RESUMO

INTRODUCTION: The aim of this work is to report diagnostic reference levels (DRLs) for hybrid positron emission tomography and x-ray computed tomography (PET/CT) exams in Australia (AU) for Queensland (QLD) and Western Australia (WA) (AU QLD/WA) and New Zealand (NZ). METHODS: Two-structured booklets were designed to collect dose information, patient demographics, equipment details and acquisition protocols for fluoride-18 fluorodeoxyglucose (18 F-FDG) PET/CT procedures, and any additional diagnostic CT routinely performed as part of 18 F-FDG whole-body examination. The DRL was reported based on the 75th percentile and achievable dose for 18 F-FDG, CT dose index volume (CTDIvol ) and dose length product (DLP). The effective dose and total effective dose was reported for 18 F-FDG whole-body PET/CT examination. Also, the effective dose was reported separately for identified additional diagnostic CT. RESULTS: The findings of this study show that the current DRL for 18 F-FDG in AU QLD/WA and NZ was 333.75 MBq and 332.87 MBq, respectively. The reported AU QLD/WA CTDIvol and DLP associated with 18 F-FDG whole-body PET/CT examinations from vertex to thigh (VT) was 4.41 mGy and 474 mGy.cm. In NZ, the reported VT CTDIvol and DLP was 13.07 mGy and 1319.05 mGy.cm. The effective dose for 18 F-FDG and CT component was 5.6 mSv and 4.7 mSv for AU QLD/WA. For NZ, the effective dose was 5.7 mSv and 10.9 mSv for 18 F-FDG and CT component. The total effective dose delivered from the 18 F-FDG whole-body scan from the AU QLD/WA PET/CT centres (10.44 mSv) were lower than the radiation doses delivered from the NZ (16.65 mSv). CONCLUSIONS: The current DRLs were proposed for AU QLD/WA and NZ for 18 F-FDG whole-body PET/CT examinations. Variations existed in the current practice of AU QLD/WA and NZ PET/CT examinations. There is a need to optimize the radiation doses delivered from PET/CT examinations.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Imagem Corporal Total/normas , Fluordesoxiglucose F18 , Humanos , Nova Zelândia , Queensland , Doses de Radiação , Compostos Radiofarmacêuticos , Valores de Referência , Inquéritos e Questionários , Austrália Ocidental
19.
Radiology ; 291(1): 5-13, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30806604

RESUMO

Acknowledging the increasingly important role of whole-body MRI for directing patient care in myeloma, a multidisciplinary, international, and expert panel of radiologists, medical physicists, and hematologists with specific expertise in whole-body MRI in myeloma convened to discuss the technical performance standards, merits, and limitations of currently available imaging methods. Following guidance from the International Myeloma Working Group and the National Institute for Clinical Excellence in the United Kingdom, the Myeloma Response Assessment and Diagnosis System (or MY-RADS) imaging recommendations are designed to promote standardization and diminish variations in the acquisition, interpretation, and reporting of whole-body MRI in myeloma and allow response assessment. This consensus proposes a core clinical protocol for whole-body MRI and an extended protocol for advanced assessments. Published under a CC BY 4.0 license. Online supplemental material is available for this article.


Assuntos
Mieloma Múltiplo/diagnóstico , Guias de Prática Clínica como Assunto , Consenso , Coleta de Dados , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Projetos de Pesquisa , Imagem Corporal Total/métodos , Imagem Corporal Total/normas
20.
Emerg Med Australas ; 31(3): 399-404, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30175454

RESUMO

OBJECTIVES: Whole body computed tomography (WBCT) scanning for trauma has gained popularity but its role in low-risk patients is controversial. We aimed to determine the rate of serious axial/truncal injury and emergency intervention in conscious, stable patients undergoing WBCT for blunt trauma in two non-trauma centre EDs in the Victorian trauma system. METHODS: Retrospective cohort study by medical record and radiology report review. Patients were included if they were conscious, haemodynamically stable adults presenting by ambulance and having WBCT scan. Exclusion criteria were age <16 years, no history of trauma, Glasgow Coma Scale <14, systolic blood pressure <90 mmHg and intoxication with alcohol or drugs. Data collected included demographics, clinical findings, results of CT scans and emergency interventions (emergency truncal surgery, transfer to a trauma centre and/or transfusion within 24 h). The outcomes of interest were the rate of defined serious axial/truncal injury and emergency interventions. RESULTS: One hundred and four patients were studied. Median age was 45 years; 67% were men. Median injury severity score (ISS) was 1.5 (interquartile range 0-5); only one patient had an ISS ≥15. Ninety (87%, 78-92%) patients had no defined serious injury. Five (5%) patients had a defined emergency intervention - four trauma centre transfers and one transfusion. Two of these were not trauma-related. CONCLUSION: The rate of serious axial/truncal injury was low. The high rate of normal scans makes it likely that the risk:benefit ratio between injury identification and radiation related cancer risk is unacceptably high. This data supports a selective CT strategy in low-risk trauma patients.


Assuntos
Suporte de Carga/fisiologia , Imagem Corporal Total/normas , Ferimentos e Lesões/diagnóstico , Ferimentos não Penetrantes/diagnóstico por imagem , Adulto , Estudos de Coortes , Feminino , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Vitória/epidemiologia , Imagem Corporal Total/métodos , Imagem Corporal Total/estatística & dados numéricos , Ferimentos e Lesões/diagnóstico por imagem , Ferimentos e Lesões/epidemiologia , Ferimentos não Penetrantes/diagnóstico , Ferimentos não Penetrantes/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...