Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.163
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 474, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38880911

RESUMO

BACKGROUND: The treatment of infected bone defects remains a clinical challenge. With the development of three-dimensional printing technology, three-dimensional printed implants have been used for defect reconstruction. The aim of this study was to investigate the clinical outcomes of three-dimensional printed porous prosthesis in the treatment of femoral defects caused by osteomyelitis. METHODS: Eleven patients with femoral bone defects following osteomyelitis who were treated with 3D-printed porous prosthesis at our institution between May 2017 and July 2021, were included. Eight patients were diagnosed with critical-sized defects, and the other three patients were diagnosed with shape-structural defects. A two-stage procedure was performed for all patients, and the infection was eradicated and bone defects were occupied by polymethylmethacrylate spacer during the first stage. The 3D-printed prosthesis was designed and used for the reconstruction of femoral defects in the second stage. Position of the reconstructed prostheses and bone growth were measured using radiography. The union rate, complications, and functional outcomes at the final follow-up were assessed. RESULTS: The mean length of the bone defect was 14.0 cm, union was achieved in 10 (91%) patients. All patients showed good functional performance at the most recent follow-up. In the critical-sized defect group, one patient developed a deep infection that required additional procedures. Two patients had prosthetic dislocations. Radiography demonstrated good osseous integration of the implant-bone interface in 10 patients. CONCLUSION: The 3D printed prostheses enable rapid anatomical and mechanically stable reconstruction of extreme femur bone defects, effectively shortens treatment time, and achieves satisfactory clinical outcomes.


Assuntos
Fêmur , Osteomielite , Impressão Tridimensional , Desenho de Prótese , Titânio , Humanos , Osteomielite/cirurgia , Osteomielite/etiologia , Osteomielite/diagnóstico por imagem , Masculino , Feminino , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Pessoa de Meia-Idade , Adulto , Porosidade , Resultado do Tratamento , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Idoso , Adulto Jovem , Procedimentos de Cirurgia Plástica/métodos , Procedimentos de Cirurgia Plástica/instrumentação
2.
Methodist Debakey Cardiovasc J ; 20(3): 49-56, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38765211

RESUMO

For patients with existing venous thromboembolisms (VTEs), anticoagulation remains the standard of care recommended across multiple professional organizations. However, for patients who developed a deep venous thrombosis (DVT) and/or a pulmonary embolism and cannot tolerate anticoagulation, inferior vena cava (IVC) filters must be considered among other alternative treatments. Although placement of a filter is considered a low-risk intervention, there are important factors and techniques that surgeons and interventionalists should be aware of and prepared to discuss. This overview covers the basics regarding the history of filters, indications for placement, associated risks, and techniques for difficult removal.


Assuntos
Remoção de Dispositivo , Desenho de Prótese , Implantação de Prótese , Embolia Pulmonar , Filtros de Veia Cava , Trombose Venosa , Humanos , Embolia Pulmonar/prevenção & controle , Trombose Venosa/prevenção & controle , Trombose Venosa/terapia , Fatores de Risco , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Resultado do Tratamento , Tromboembolia Venosa/prevenção & controle , Tromboembolia Venosa/diagnóstico , Veia Cava Inferior/diagnóstico por imagem , Medição de Risco , Anticoagulantes/uso terapêutico , Anticoagulantes/efeitos adversos
3.
Int J Cardiol ; 407: 132113, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38697398

RESUMO

BACKGROUND: Axillary vein puncture (AVP) is a valid alternative to Subclavan vein puncture for leads insertion in cardiac implantable electronic device implantation, that may reduce acute and delayed complications. Very few data are available about ICD recipients. A simplified AVP technique is described. METHODS: All the patients who consecutively underwent "de novo" ICD implantation, from March 2006 to December 2020 at the University of Verona, were considered. Leads insertion was routinely performed through an AVP, according to a simplified technique. Outcome and complications have been retrospectively analyzed. RESULTS: The study population consisted of 1711 consecutive patients. Out of 1711 patients, 38 (2.2%) were excluded because they were implanted with Medtronic Sprint Fidelis lead. Out of 1673 ICD implantations, 963 (57.6%) were ICD plus cardiac resynchronization therapy, 434 (25.9%) were dual-chamber defibrillators, and 276 (16.5%) were single-chamber defibrillators, for a total of 3879 implanted leads. The AVP success rate was 99.4%. Acute complications occurred in 7/1673 (0.42%) patients. Lead failure (LF) occurred in 20/1673 (1.19%) patients. Comparing the group of patients with lead failure with the group without LF, the presence of three leads inside the vein was significantly associated with LF, and the multivariate analysis confirmed three leads in place as an independent predictor of LF. CONCLUSION: AVP, according to our simplified technique, is safe, effective, has a high success rate, and a very low complication rate. The incidence of LF was exceptionally low. The advantages of AVP are maintained over time in a population of ICD recipients.


Assuntos
Veia Axilar , Desfibriladores Implantáveis , Punções , Humanos , Desfibriladores Implantáveis/efeitos adversos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Veia Axilar/diagnóstico por imagem , Implantação de Prótese/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Resultado do Tratamento , Fatores de Tempo
4.
Am J Otolaryngol ; 45(4): 104328, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38733715

RESUMO

PURPOSE: To evaluate outcomes following explantation of percutaneous or transcutaneous bone conduction implants (pBCIs or tBCIs) and subsequent implantation of transcutaneous active bone conduction hearing devices (BCHDs); to provide guidance regarding staging of surgery and adjunctive procedures. MATERIALS AND METHODS: Retrospective chart review of eight adult subjects (ten ears) with pBCIs or tBCIs who underwent explantation of their device and subsequent implantation with a BCHD [MED-EL BONEBRIDGE™ (n = 7, 70 %) or Cochlear™ Osia® (n = 3, 30 %)]. RESULTS: Reasons for pBCI or tBCI explantation were pain (60 %, 6/10), infection (60 %, 6/10), skin overgrowth (50 %, 5/10), and inability to obtain new processors (20 %, 2/10). Median time between pBCI or tBCI removal and BCHD staged implant was 4.7 (IQR 2.2-8.1) months. Two subjects developed complications following BCHD implantation. One had a persistent wound overlying the osseointegrated screw after removal of the pBCI abutment, requiring removal and temporalis rotational flap. Staged Osia® implantation was performed, but ultimately wound dehiscence developed over the device. The second subject experienced an infection after BONEBRIDGE™ implantation (32 days after pBCI explant), necessitating washout and treatment with intravenous antibiotics. There was subsequent device failure. CONCLUSION: The transition from a pBCI or tBCI to a novel transcutaneous device is nuanced. Staged pBCI or tBCI explantation and novel BCHD implantation with sufficient time for wound healing is vital. Adjunctive procedures to augment soft tissue in cases of prior attenuation may be required to avoid complications with larger internal devices.


Assuntos
Condução Óssea , Remoção de Dispositivo , Auxiliares de Audição , Humanos , Auxiliares de Audição/efeitos adversos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Resultado do Tratamento , Idoso , Prótese Ancorada no Osso , Implantação de Prótese/métodos , Implantação de Prótese/efeitos adversos , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva/etiologia
5.
Catheter Cardiovasc Interv ; 103(6): 909-916, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584525

RESUMO

BACKGROUND: Utilization of right ventricular mechanical circulatory support (RV-MCS) devices has been limited by a lack of recognition of RV failure as well as a lack of availability and experience with RV-MCS. AIMS: We report a single-center experience with the use of percutaneous RV-MCS and report predictors of adverse outcomes. METHODS: This was a single-center retrospective cohort study. Data from consecutive patients who received RV-MCS for any indication between June 2015 and January 2022 were included. Data on baseline comorbidities, hemodynamics, and laboratory values were collected. The primary outcome was in-hospital mortality analyzed as a logistic outcome in a multivariable model. These variables were further ranked by their predictive value. RESULTS: Among 58 consecutive patients enrolled, the median age was 66 years, 31% were female and 53% were white. The majority of the patients (48%) were hospitalized for acute on chronic heart failure. The majority of the patients were SCAI SHOCK Stage D (67%) and 34 (64%) patients had MCS placed within 24 h of the onset of shock. Before placement of RV-MCS, median central venous pressure (CVP) and RV stroke work index were 20 mmHg and 8.9 g m/m2, respectively. Median serum lactate was 3.5 (1.6, 6.2) mmol/L. Impella RP was implanted in 50% and ProtekDuo in the remaining 50%. Left ventricular MCS was concomitantly used in 66% of patients. Twenty-eight patients (48.3%) died. In these patients, median serum lactate was significantly higher (4.1 [2.3, 13.0] vs. 2.2 [1.4, 4.0] mmol/L, p = 0.007) and a trend toward higher median CVP (24 [18, 31] vs. 19 [14, 24] mmHg, p = 0.052). In the multivariable logistic model, both serum lactate and CVP before RV-MCS placement were independent predictors of in-hospital mortality. Serum lactate had the highest predictive value. CONCLUSION: In our real-world cohort, 52% of patients treated with RV-MCS survived their index hospitalization. Serum lactate at presentation and CVP were the strongest predictors of in-hospital mortality.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Mortalidade Hospitalar , Recuperação de Função Fisiológica , Disfunção Ventricular Direita , Função Ventricular Direita , Humanos , Feminino , Masculino , Estudos Retrospectivos , Idoso , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/diagnóstico , Resultado do Tratamento , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/mortalidade , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/terapia , Disfunção Ventricular Direita/diagnóstico por imagem , Medição de Risco , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Implantação de Prótese/mortalidade , Biomarcadores/sangue
6.
J Cardiovasc Electrophysiol ; 35(6): 1196-1202, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38590268

RESUMO

INTRODUCTION: Ventricular tachycardia storm or electrical storm (ES) is a common complication following left ventricular assist device (LVAD) implantation. The factors contributing to ES and outcomes are less studied. The study aimed to determine the factors associated with ES and the probability of survival in patients undergoing LVAD in three tertiary centers over a span of 15 years. METHODS: We performed a retrospective cohort study on all patients who underwent LVAD implantation at the Mayo Clinic (Rochester, Phoenix, and Jacksonville) from January 1, 2006 to December 31, 2020. ES was defined as ≥3 episodes of sustained ventricular tachycardia over a period of 24 h with no identifiable reversible cause. Detailed chart reviews of the electronic health records within the Mayo Clinic and outside medical records were performed. RESULTS: A total of 883 patients who underwent LVAD implantation were included in our study. ES occurred in 7% (n = 61) of patients with a median of 13 days (interquartile range [IQR]: 5-297 days) following surgery. We found 57% of patients (n = 35) developed ES within 30 days, while 43% (n = 26) patients developed ES at a median of 545  (IQR 152-1032) days after surgery. Following ES, 26% of patients died within 1 year. Patients with ES had a significant association with a history of ventricular arrhythmias and implantable cardioverter defibrillator (ICD) shocks before the procedure. ES was significantly associated with reduced survival compared to patients without ES (hazards ratio [HR]: 1.92, 95% CI: 1.39-2.64, p < .001). CONCLUSION: Following LVAD implantation, the rate of ES was 7% with majority of ES occurring within 30 days of LVAD. Risk factors for ES included pre-implant history of ventricular arrhythmias and ICD shock. ES was significantly associated with reduced survival compared to patients without ES.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Implantação de Prótese , Taquicardia Ventricular , Função Ventricular Esquerda , Humanos , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/etiologia , Resultado do Tratamento , Idoso , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/mortalidade , Medição de Risco , Potenciais de Ação , Frequência Cardíaca , Adulto
7.
J Cardiovasc Electrophysiol ; 35(6): 1212-1216, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38650520

RESUMO

BACKGROUND: Early guidance recommended a bolus of intravenous heparin at the beginning of leadless pacemaker (LP) implantation procedures. However, due to concern about bleeding complications, more recent practice has tended toward omitting the bolus and only running a continuous heparin infusion through the introducer sheath. The impact of omitting the heparin bolus on procedural outcomes is not clear. METHODS: We reviewed all Medtronic Micra LP implants at our institution from 9/2014 to 9/2022. The decision to bolus with heparin was at operator discretion. RESULTS: Among 621 LP implants, 326 received an intravenous heparin bolus, 243 did not, and 52 patients were excluded because heparin bolus status could not be confirmed. There was a trend toward more frequent omission of the heparin bolus with more recent implants. Median follow-up after LP implant was 14.3 (interquartile range [IQR]: 8.4-27.9) months. There was no difference between heparin bolus and no bolus groups in the number of device deployments/recaptures (1.42 ± 0.81 vs. 1.31 ± 0.66, p = .15). Implant-related adverse events were also similar between heparin bolus and no bolus groups: access-site hematoma requiring intervention (7 vs. 5, p = .99), pseudoaneurysm (1 vs. 1, p = .99), cardiac perforation (1 vs. 1, p = .99), intraprocedural device thrombus formation (2 vs. 4, p = .41), 30-day rehospitalization (21 vs. 15, p = .98), and 30-day all-cause mortality (16 vs. 14, p = .70). There was one additional nonfatal cardiac perforation in a patient who was excluded due to unknown heparin bolus status. Regarding device electrical parameters between heparin bolus and no bolus groups, there were no significant differences at the time of implant: pacing capture threshold 0.5 ± 0.4 vs. 0.5 ± 0.3, p = .10; pacing impedance 739.9 ± 226.4 vs. 719.1 ± 215.4, p = .52; R wave sensing 11.7 ± 5.7 vs. 12.0 ± 5.4, p = .34). Long-term device performance was also similar between groups. CONCLUSION: Omission of the systemic heparin bolus at the time of LP implantation appears safe in appropriately selected patients. Heparin bolus may still be considered in long cases requiring multiple device deployments or in patients at high risk for thrombotic complications.


Assuntos
Anticoagulantes , Estimulação Cardíaca Artificial , Heparina , Marca-Passo Artificial , Humanos , Heparina/administração & dosagem , Heparina/efeitos adversos , Masculino , Idoso , Feminino , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Tempo , Fatores de Risco , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Esquema de Medicação , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Desenho de Prótese
8.
J Cardiovasc Electrophysiol ; 35(5): 1041-1045, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38462703

RESUMO

INTRODUCTION: Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. METHODS AND RESULTS: Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same-day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. CONCLUSIONS: We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.


Assuntos
Estimulação Cardíaca Artificial , Veias Jugulares , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Veias Jugulares/cirurgia , Feminino , Idoso , Resultado do Tratamento , Desenho de Equipamento , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos
9.
Arq Bras Oftalmol ; 87(3): e20230033, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537046

RESUMO

PURPOSE: This study aims to compare the initial ocular discomfort symptoms resulting from trabeculectomy and Ahmed glaucoma valve implantation surgeries. METHODS: A prospective comparative study was conducted. The evaluation of ocular discomfort employed a questionnaire designed to identify the frequency and severity of distinct symptoms: ocular pain, general discomfort, tearing, foreign body sensation, and burning. This questionnaire was administered prior to surgery as a baseline, and subsequently at 7, 30, and 90 days post-surgery. Simultaneously, the Ocular Surface Disease Index (OSDI) was applied at these same time intervals. RESULTS: The study encompassed a total of 17 patients (9 undergoing trabeculectomy and 8 undergoing Ahmed glaucoma valve implantation). The Ahmed glaucoma valve implantation group exhibited higher tearing levels at baseline (p=0.038). However, no statistically significant differences in symptoms were observed between the two surgeries at 7 and 30 days post-surgery. At the 90-day mark following surgery, patients who had undergone trabeculectomy reported a significantly higher foreign body sensation (p=0.004). Although OSDI scores did not differ between groups at baseline, the trabeculectomy group showed significantly higher OSDI scores than the Ahmed glaucoma valve implantation group at 7, 30, and 90 days after surgery (p<0.05). CONCLUSION: Post-surgery, patients who had undergone trabeculectomy experienced increased foreign body sensation. Trabeculectomy appears to cause greater early postoperative ocular discomfort compared to the Ahmed glaucoma valve implantation group.


Assuntos
Corpos Estranhos , Implantes para Drenagem de Glaucoma , Glaucoma , Trabeculectomia , Humanos , Trabeculectomia/efeitos adversos , Estudos Prospectivos , Pressão Intraocular , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/etiologia , Implantação de Prótese/efeitos adversos , Corpos Estranhos/complicações , Corpos Estranhos/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
10.
Pacing Clin Electrophysiol ; 47(4): 496-502, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38462721

RESUMO

BACKGROUND: Inappropriate shock (IAS) caused by subcutaneous air entrapment (AE) in an early period after subcutaneous implantable cardioverter defibrillator (S-ICD) implantation has been reported, however, no detailed data on air volume are available. We evaluated the subcutaneous air volume after implantation and its absorption rate one week after implantation. METHODS: Patients who underwent S-ICD implantation in our hospital received chest CT scans immediately after implantation and followed up 1 week later. The total subcutaneous air volume, air around the generator, the distal electrode, and the proximal electrode within 3 cm were calculated using a three-dimensional workstation. Fat areas at the level of the lower edge of the generator were also analyzed. RESULT: Fifteen patients received CT immediately after implantation. The mean age was 45.6 ± 17.9 (66.7% of men), and the mean body mass index was 24.3 ± 3.3. The three-incision technique was applied in seven patients and two-incision technique was in the latter eight patients. The mean total subcutaneous air volume was 18.54 ± 7.50 mL. Air volume around the generator, the distal electrode, and the proximal electrode were 11.05 ± 5.12, 0.72 ± 0.72, and 0.88 ± 0.87 mL, respectively. Twelve patients received a follow-up CT 1 week later. The mean total subcutaneous air was 0.25 ± 0.45 mL, showing a 98.7% absorption rate. CONCLUSION: Although subcutaneous air was observed in all patients after S-ICD implantation, most of the air was absorbed within 1 week, suggesting a low occurrence of AE-related IAS after a week postoperation.


Assuntos
Desfibriladores Implantáveis , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Tomografia Computadorizada por Raios X , Tomografia , Resultado do Tratamento
11.
Rev. argent. coloproctología ; 35(1): 40-44, mar. 2024. ilus
Artigo em Espanhol | LILACS | ID: biblio-1551683

RESUMO

En este reporte presentamos tres pacientes en quienes ocurrieron condiciones inflamatorias perianales tardías, luego de la administración de sustancias modeladoras no identificadas en los glúteos. El diagnóstico inicial y supuesto no fue correcto, ya que no se investigó durante la evaluación preliminar el antecedente de la administración de elementos modeladores. Recomendamos que los pacientes con patologías inflamatorias del ano, sobre todo aquellos cuyo curso es extraño, se les pregunte acerca de la administración de agentes modeladores en los glúteos. Esta práctica puede contribuir a la eficacia del diagnóstico de manifestaciones perianales caracterizadas por flogosis, que se presentan de forma inusual. (AU)


In this report we present three patients in which late perianal inflammatory conditions occurred after administration of unidentified modeling agents to the buttocks. The initial diagnosis was not correct because of the administration of modeling agents was not investigated during the initial eval-uation. We recommend inquiring patients with inflammatory pathologies of the anus, especially those whose course is unusual, about the adminis-tration of modeling agents to the buttocks. This approach can contribute to the efficiency of the diagnosis of perianal complaints characterized by inflammation, but rare in its appearance. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Doenças do Ânus/cirurgia , Doenças do Ânus/etiologia , Biopolímeros/efeitos adversos , Nádegas/cirurgia , Doenças do Ânus/diagnóstico , Técnicas Cosméticas , Migração de Corpo Estranho , Implantação de Prótese/efeitos adversos
12.
Auris Nasus Larynx ; 51(3): 433-436, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38520973

RESUMO

Acquired tracheobronchomalacia (ATBM) is a condition in which the tracheobronchial wall and cartilage progressively lose their rigidity, resulting in dynamic collapse during exhalation. In this report, we present a case of ATBM that developed following voice prosthesis implantation. To the best of our knowledge, this is the first documented case of such a condition in the medical English literature based on a PubMed search. A 63-year-old man was referred to National Kyushu Cancer Center in Japan with complaints of pharyngeal pain and a laryngeal tumor. The tumor was diagnosed as laryngeal cancer, and the patient underwent laryngectomy. Three months after the surgery, we implanted a voice prosthesis through a tracheoesophageal puncture. Two months after implantation, the patient experienced dyspnea. This condition was subsequently diagnosed as ATBM through computed tomography and bronchofiberscope examinations. After the removal of the voice prosthesis, there has been no progression of ATBM for over five years. While ATBM may not be a common occurrence in the practice of head and neck surgeons, it should be considered as a potential complication when patients report dyspnea following voice prosthesis implantation.


Assuntos
Neoplasias Laríngeas , Laringectomia , Laringe Artificial , Traqueobroncomalácia , Humanos , Masculino , Pessoa de Meia-Idade , Laringe Artificial/efeitos adversos , Neoplasias Laríngeas/cirurgia , Laringectomia/efeitos adversos , Traqueobroncomalácia/etiologia , Traqueobroncomalácia/cirurgia , Dispneia/etiologia , Tomografia Computadorizada por Raios X , Implantação de Prótese/efeitos adversos , Complicações Pós-Operatórias/etiologia , Carcinoma de Células Escamosas/cirurgia
13.
Artif Organs ; 48(6): 655-664, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38459775

RESUMO

OBJECTIVES: Right ventricular failure following implantation of a durable left ventricular assist device (LVAD) is a major driver of mortality. Reported survival following biventricular (BiVAD) or total artificial heart (TAH) implantation remains substantially inferior to LVAD alone. We report our outcomes with LVAD and BiVAD HeartMate 3 (HM3). METHODS: Consecutive patients undergoing implantation of an HM3 LVAD between November 2014 and December 2021, at The Alfred, Australia were included in the study. Comparison was made between the BiVAD and LVAD alone groups. RESULTS: A total of 86 patients, 65 patients with LVAD alone and 21 in a BiVAD configuration underwent implantation. The median age of the LVAD and BiVAD groups was 56 years (Interquartile range 46-62) and 49 years (Interquartile range 37-55), respectively. By 4 years after implantation, 54% of LVAD patients and 43% of BiVAD patients had undergone cardiac transplantation. The incidence of stroke in the entire experience was 3.5% and pump thrombosis 5% (all in the RVAD). There were 14 deaths in the LVAD group and 1 in the BiVAD group. The actuarial survival for LVAD patients at 1 year was 85% and BiVAD patients at 1 year was 95%. CONCLUSIONS: The application of HM 3 BiVAD support in selected patients appears to offer a satisfactory solution to patients requiring biventricular support.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Adulto , Estudos Retrospectivos , Resultado do Tratamento , Transplante de Coração/métodos , Austrália/epidemiologia , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos
14.
Int J Implant Dent ; 10(1): 4, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38315326

RESUMO

PURPOSE: The aim of this study was to assess implant survival and complications rate of modern subperiosteal implants (CAD designed and additively manufactured). METHODS: A systematic review was conducted using three electronic databases; Medline (Pubmed), Cochrane library, and SCOPUS, following the PRISMA statement recommendations to answer the PICO question: "In patients with bone atrophy (P), do additively manufactured subperiosteal implants (I), compared to subperiosteal implants manufactured following traditional approaches (c), present satisfactory implant survival and complication rates (O)? The study was pre-registered in PROSPERO (CRD42023424211). Included articles quality was assessed using the "NIH quality assessment tools". RESULTS: Thirteen articles were finally selected (5 cohort studies and 8 case series), including 227 patients (121 female / 106 male; weighted mean age 62.4 years) and 227 implants. After a weighted mean follow-up time of 21.4 months, 97.8% of implants were in function (5 failures reported), 58 implants (25.6%) presented partial exposure, 12 patients (5.3%) suffered soft tissue or persistent infection. Fracture of the interim prosthesis was reported in 8 of the155 patients (5.2%) in which the use of a provisional prosthesis was reported. A great heterogeneity was found in terms of study design and methodological aspects. For this reason, a quantitative analysis followed by meta-analysis was not possible. CONCLUSIONS: Within the limitations of this study, modern additively manufactured subperiosteal implants presented a good survival in the short-time, but a noticeable number of soft-tissue related complications were reported. Further studies are needed to assess the clinical behavior in the medium- and long-term.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Falha de Restauração Dentária , Implantação de Prótese/efeitos adversos , Perda do Osso Alveolar/etiologia , Prótese Dentária Fixada por Implante/efeitos adversos
15.
J Shoulder Elbow Surg ; 33(5): 1104-1115, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38360351

RESUMO

BACKGROUND: Distal humerus replacement (DHR) is a modular endoprosthesis mainly used for bone reconstruction after resection of primary or metastatic bone lesions. Studies on DHR failure rates and postoperative functional outcomes are scarce. We sought to assess implant survival, modes of failure, and functional outcomes in patients undergoing DHR for oncologic indications. METHODS: A systematic review of the PubMed and Embase databases was performed. PRISMA guidelines were followed for this manuscript. Our study was registered on PROSPERO (457,260). Quality appraisal of included studies was conducted using the STROBE checklist. Prosthetic failure was assessed using the Henderson classification for megaprosthetic failures. We additionally performed a retrospective review of patients treated with a DHR for oncologic indications at a large tertiary care academic center. Weighted means were calculated to pool data. RESULTS: Eleven studies with a total of 162 patients met the inclusion criteria. Mean follow-up was 3.7 years (range, 1.66-8 years). Henderson type 2 failures (aseptic loosening) were the most common mode of failure, occurring in 12% of cases (range, 0%-33%). Five-year implant survival was 72% (range, 49%-93.7%). Mean postoperative Musculoskeletal Tumor Society (MSTS) score was 81.1 (range, 74-84.3). In our institutional case series, 2 out of 5 patients had DHR revision for periprosthetic fracture and aseptic loosening at 16 and 27 months after surgery, respectively. CONCLUSIONS: Distal humerus replacement is a successful reconstruction strategy for tumors of the distal humerus, with high implant survival and good to excellent functional outcomes.


Assuntos
Neoplasias Ósseas , Cotovelo , Humanos , Cotovelo/cirurgia , Neoplasias Ósseas/cirurgia , Neoplasias Ósseas/patologia , Resultado do Tratamento , Implantação de Prótese/efeitos adversos , Úmero/patologia , Estudos Retrospectivos , Falha de Prótese
16.
J Cardiovasc Transl Res ; 17(2): 252-264, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38300356

RESUMO

This study aims to associate the incidence of postoperative vasoplegia and short-term survival to the implantation of various left ventricular assist devices differing in hemocompatibility and flow profiles. The overall incidence of vasoplegia was 25.3% (73/289 patients) and 30.3% (37/122), 25.0% (18/72), and 18.9% (18/95) in the axial flow (AXF), centrifugal flow (CF), and centrifugal flow with artificial pulse (CFAP) group, respectively. Vasoplegia was associated with longer intensive care (ICU) and hospital length of stay (LOS) and mortality. ICU and in-hospital LOS and 1-year mortality were the lowest in the CFAP group. Post hoc analysis resulted in a p-value of 0.43 between AXF and CF; 0.35 between CF and CFAP; and 0.06 between AXF and CFAP. Although there is a trend in diminished incidence of vasoplegia, pooled logistic regression using flow profile and variables that remained after feature selection showed that flow profile was not an independent predictor for postoperative vasoplegia.


Assuntos
Coração Auxiliar , Tempo de Internação , Desenho de Prótese , Vasoplegia , Função Ventricular Esquerda , Humanos , Vasoplegia/fisiopatologia , Vasoplegia/etiologia , Vasoplegia/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Incidência , Fatores de Risco , Adulto , Idoso , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Implantação de Prótese/mortalidade , Estudos Retrospectivos , Mortalidade Hospitalar , Medição de Risco
17.
Artif Organs ; 48(4): 408-417, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38380771

RESUMO

BACKGROUND: Mechanical cardiac support is currently an effective strategy to reduce morbidity and mortality in pediatric patients. However, solid evidence regarding the feasibility of intracorporeal devices in children still needs to be provided. We report our 10-year experience with intracorporeal left ventricular assist devices (LVAD) in children. MATERIALS AND METHODS: We included all patients undergoing intracorporeal, continuous-flow LVAD implantation between 2012 and 2022. Baseline and postoperative data were collected from the institutional database. RESULTS: Seven HeartWare and 4 HeartMate3 were implanted in 11 patients (median age 13.9 years, median body surface area - BSA - 1.42 m2, IQR 1.06-1.68). The most frequent indication to LVAD implant was dilated cardiomyopathy (72.7%). All candidates underwent a thorough preoperative advanced imaging. Three-dimensional reconstructions and implant fit simulation were performed when BSA was <1.2 m2, weight <30 kg, or internal transverse thoracic diameter <20 cm. There was no operative death. The most common postoperative complication was surgical re-exploration due to bleeding (27.3%). One patient died of severe neurological complications after about 3 months of hospitalization. No late deaths or unplanned re-hospitalizations occurred in the remaining 10, 6 of whom were discharged home. There were no major complications at the follow-up. All survivors underwent successful heart transplantation. CONCLUSIONS: Intracorporeal LVAD implantation proved to be a potentially feasible and safe option in young teenagers and children whose BSA was >1.0 m2. In borderline cases, the 3D reconstruction with implant fit simulation can effectively help to identify those patients who can safely undergo intrathoracic LVAD implantation.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adolescente , Humanos , Criança , Insuficiência Cardíaca/cirurgia , Implantação de Prótese/efeitos adversos , Complicações Pós-Operatórias , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
18.
Vasc Endovascular Surg ; 58(5): 559-566, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38196287

RESUMO

INTRODUCTION AND IMPORTANCE: Long-term mechanical complications after inferior vena cava (IVC) filter placement include embedded or tilted filters, erosion of the vena cava, filter thrombosis. In the setting of caval thrombosis, patients may subsequently develop venous hypertension and post-thrombotic syndrome (PTS). Here we present three unique cases of IVC filter complications and surgical management. CASE PRESENTATION: A 30-year-old female presented with acute abdominal pain, revealing a duodenal perforation caused by an IVC filter eroding into her duodenum. A 42-year-old female with an IVC filter in place for 20 years due to a prior pulmonary embolism underwent laser-assisted retrieval of the filter due to concerns of caval adherence. A 48-year-old male with a history of DVT, venous stasis ulcer, and an IVC filter presented for filter retrieval. CLINICAL FINDINGS AND INVESTIGATIONS: The surgical techniques described in this report include complicated IVC filter retrieval, performed in cases of filter complications including migration, fracture, duodenal perforation and IVC thrombosis resulting in PTS. One case, requiring open retrieval, is explained and the surgical technique is provided. There are images and videos of these procedures to enrich the learning experience. INTERVENTION AND OUTCOMES: The surgical techniques described in this report include complicated inferior vena cava filter retrieval, performed in cases of filter complications including migration, fracture, duodenal perforation and IVC thrombosis. One case, requiring open retrieval, is explained and the surgical technique is provided. There are images and videos of these procedures to enrich the learning experience. RELEVANCE AND IMPACT: Endovascular retrieval of long-term complicated IVC filters is challenging, but it can be a safely performed in many patients. However, open surgery may be necessary in selected patients.


Assuntos
Remoção de Dispositivo , Migração de Corpo Estranho , Filtros de Veia Cava , Veia Cava Inferior , Trombose Venosa , Humanos , Filtros de Veia Cava/efeitos adversos , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Resultado do Tratamento , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/cirurgia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/lesões , Veia Cava Inferior/cirurgia , Trombose Venosa/etiologia , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/terapia , Perfuração Intestinal/etiologia , Perfuração Intestinal/cirurgia , Perfuração Intestinal/diagnóstico por imagem , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Fatores de Tempo , Desenho de Prótese , Flebografia
19.
Perfusion ; 39(3): 514-524, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36602044

RESUMO

OBJECTIVES: In patients at risk of developing right ventricular failure after cardiac surgery, right ventricular support with a ventricular assist device may be a promising strategy to reduce mortality. We present our experience with intraoperative right ventricular assist device implantation as a prevention strategy of right ventricular failure after cardiac surgery. METHODS: Between 2016 and 2022, we implanted four right ventricular assist devices prophylactically in a series of patients with surgical indication for valvular heart disease and high risk of postoperative right ventricular failure. Indications for the right ventricular assist device were suprasystemic pulmonary hypertension or severe right ventricular dysfunction. RESULTS: Externalization of the device cannulas through intercostal spaces was performed in three patients, allowing early mobilization and withdrawal without resternotomy. Removal of the device ocurred on the eighth postoperative day. ICU and hospital length of stay was 12 (±1.6) and 23 days (±4.2) respectively. Hospital mortality was null. No patient died during follow-up, mean follow-up was 32.5 months [1-72]. Patients improved their NYHA functional class up to grade II during follow-up. CONCLUSIONS: Acute right ventricular failure after cardiac surgery remains a significant cause of morbidity and mortality. Prophylactic strategies to prevent postoperative right ventricular dysfunction may decrease the incidence of refractory postoperative right ventricular failure. We propose a novel approach to prevent right failure after cardiac surgery with prophylactic intraoperative ventricular assist device implantation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Humanos , Coração Auxiliar/efeitos adversos , Implantação de Prótese/efeitos adversos , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/prevenção & controle , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência Cardíaca/prevenção & controle , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos
20.
Eur Urol ; 85(2): 139-145, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37914580

RESUMO

BACKGROUND: Periprostatic artificial urinary sphincter implantation (pAUSi) is a rare yet relevant indication for male neurogenic stress urinary incontinence (SUI). OBJECTIVE: To describe the surgical technique of robot-assisted pAUSi (RApAUSi) and compare the long-term functional results with the open pAUSi (OpAUSi). DESIGN, SETTING, AND PARTICIPANTS: Data of 65 consecutive men with neurogenic SUI undergoing pAUSi between 2000 and 2022 in a tertiary centre were collected retrospectively. SURGICAL PROCEDURE: Thirty-three patients underwent OpAUSi and 32 underwent RApAUSi. OpAUSi cases were performed by a single surgeon, experienced in functional urology and prosthetic surgery. RApAUSi cases were performed by the same surgeon together with a second surgeon, experienced in robotic surgery. MEASUREMENTS: Outcome measures were achievement of complete urinary continence, intra- and postoperative complications, and surgical revision-free survival (SRFS). RESULTS AND LIMITATIONS: RApAUSi showed superior results to OpAUSi in terms of median (interquartile range) operative time (RApAUSi: 170 [150-210] min vs OpAUSi: 245 [228-300] min; p < 0.001), estimated blood loss (RApAUSi: 20 [0-50] ml vs OpAUSi: 500 [350-700] ml; p < 0.001), and median length of hospital stay (LOS; RApAUSi: 5 [4-6] d vs OpAUSi: 11 [10-14] d; p < 0.001). Clavien-Dindo grade ≥3a complications occurred more frequently after OpAUSi (RApAUSi: 1/32 [3%] vs OpAUSi: 10/33 [30%]; p = 0.014). Achievement of complete urinary continence (zero pads) was comparable between the groups (RApAUSi: 24/32 [75%] vs OpAUSi: 24/33 [73%]; p = 0.500). The median follow-up periods were 118 (50-183) and 56 (25-84) mo for OpAUSi and RApAUSi, respectively (p < 0.001). A tendency towards longer SRFS was observed in the RApAUSi group (p = 0.076). The main study limitation was its retrospective nature. CONCLUSIONS: RApAUSi is an efficient alternative to OpAUSi, resulting in shorter operative times, less blood loss, fewer severe complications, and a shorter LOS with similar functional results and need for revision surgery. PATIENT SUMMARY: Compared with open periprostatic artificial urinary sphincter implantation (pAUSi), robot-assisted pAUSi leads to faster recovery and similar functional results, with fewer postoperative complications.


Assuntos
Robótica , Incontinência Urinária por Estresse , Esfíncter Urinário Artificial , Humanos , Masculino , Incontinência Urinária por Estresse/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Esfíncter Urinário Artificial/efeitos adversos , Procedimentos Cirúrgicos Urológicos/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Complicações Pós-Operatórias/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...