1.
Biologicals ; 58: 1-6, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30639575

RESUMO

The present study was aimed to establish the First National Reference Standard (NRS) for Insulin lispro to allow stakeholders including manufacturer's laboratories, drug testing laboratories, drug regulatory authorities and academic institutions to demonstrate accuracy of the test results and to enable comparison and validation of analytical methods. The candidate standard for Insulin lispro was evaluated in a collaborative study to assign the vial content in order to serve it as NRS to support the Indian Pharmacopoeia (IP) monograph. The candidate standard was calibrated against the Ph. Eur. Insulin lispro reference standard by each of six participant laboratories in India using HPLC assay method as per the requirements of IP monograph. The results indicate that the candidate standard has an average content of 5.79 mg per vial with purity of 99.87%. Based on the study results the candidate standard was judged suitable to serve as the first NRS for Insulin lispro.


Assuntos
Insulina Lispro/química , Insulina Lispro/normas , Europa (Continente) , Humanos , Índia , Padrões de Referência