Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 143: 113-122, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30408634

RESUMO

Positron-emitting 72As is the PET imaging counterpart for beta-emitting 77As. Its parent, no carrier added (n.c.a.) 72Se, was produced for a 72Se/72As generator by irradiating an enriched 7°Ge metal-graphite target via the 70Ge(α, 2 n)72Se reaction. Target dissolution used a fast, environmentally friendly method with 93% radioactivity recovery. Chromatographic parameters of the 72Se/72As generator were evaluated, the eluted n.c.a. 72As was characterized with a phantom imaging study, and the previously reported trithiol and aryl-dithiol ligand systems were radiolabeled with the separated n.c.a. 72As in high yield.


Assuntos
Arsênio/isolamento & purificação , Radioisótopos/isolamento & purificação , Geradores de Radionuclídeos , Compostos Radiofarmacêuticos/isolamento & purificação , Radioisótopos de Selênio/isolamento & purificação , Germânio/química , Germânio/isolamento & purificação , Germânio/efeitos da radiação , Humanos , Isótopos/química , Isótopos/isolamento & purificação , Isótopos/efeitos da radiação , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons , Ensaio Radioligante , Compostos Radiofarmacêuticos/síntese química , Compostos Radiofarmacêuticos/química
2.
Appl Radiat Isot ; 96: 122-128, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25484305

RESUMO

(99)Mo photonuclear yield was measured using high-energy electrons from Laser Plasma Accelerators and natural molybdenum. Spectroscopically resolved electron beams allow comparisons to Monte Carlo calculations using known (100)Mo(γ,n)(99)Mo cross sections. Yields are consistent with published low-energy data, and higher energy data are well predicted from the calculations. The measured yield is (15±2)×10(-5) atoms/electron (0.92±0.11 GBq/µA) for 25 mm targets at 33.7 MeV, rising to (1391±20)×10(-5) atoms/electron (87±2 GBq/µA) for 54 mm/ 1.7 GeV, with peak power-normalized yield at 150 MeV.


Assuntos
Molibdênio/efeitos da radiação , Compostos Radiofarmacêuticos/isolamento & purificação , Tecnécio/isolamento & purificação , Cobre/efeitos da radiação , Radioisótopos de Cobre/efeitos da radiação , Contaminação de Medicamentos , Elétrons , Raios gama , Humanos , Isótopos/efeitos da radiação , Método de Monte Carlo , Nióbio/isolamento & purificação , Radioisótopos/isolamento & purificação
3.
Appl Radiat Isot ; 94: 344-348, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25305527

RESUMO

Proton-induced nuclear reactions for generation of (99)Mo and (99m)Tc radionuclides were investigated using the stacked-foil activation technique on 99.05% enriched (100)Mo targets at energies up to Ep=21MeV. Excitation functions of the reactions (100)Mo(p,x)(99)Mo and (100)Mo(p,2n)(99m)Tc have been measured.


Assuntos
Marcação por Isótopo/métodos , Modelos Químicos , Molibdênio/química , Molibdênio/efeitos da radiação , Tecnécio/química , Tecnécio/efeitos da radiação , Simulação por Computador , Isótopos/química , Isótopos/efeitos da radiação , Teste de Materiais , Molibdênio/isolamento & purificação , Fótons , Tecnécio/isolamento & purificação
4.
Appl Radiat Isot ; 94: 131-140, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25169133

RESUMO

Cross section data for formation of the medically important radionuclide (61)Cu (T½=3.33h) in proton and deuteron induced reactions on enriched (64)Zn and in (3)He- and α-particle induced reactions on (59)Co were analyzed by using the nuclear model calculational codes, EMPIRE and TALYS. A well-defined statistical procedure was then employed to derive the recommended excitation functions, and therefrom to obtain integral yields. A comparison of major production routes of (61)Cu was done.


Assuntos
Isótopos do Cobalto/química , Radioisótopos de Cobre/química , Deutério/química , Hélio/química , Marcação por Isótopo/métodos , Modelos Químicos , Isótopos de Zinco/química , Isótopos do Cobalto/efeitos da radiação , Simulação por Computador , Radioisótopos de Cobre/isolamento & purificação , Radioisótopos de Cobre/efeitos da radiação , Deutério/efeitos da radiação , Hélio/efeitos da radiação , Isótopos/química , Isótopos/efeitos da radiação , Prótons , Doses de Radiação , Isótopos de Zinco/efeitos da radiação
5.
Appl Radiat Isot ; 88: 143-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24485172

RESUMO

In order to measure the spatial distributions of neutrons and gamma rays separately using the imaging plate, the requirement for the converter to enhance specific component was investigated with the PHITS code. Consequently, enhancing fast neutrons using recoil protons from epoxy resin was not effective due to high sensitivity of the imaging plate to gamma rays. However, the converter of epoxy resin doped with (10)B was found to have potential for thermal and epithermal neutrons, and graphite for gamma rays.


Assuntos
Bismuto/química , Terapia por Captura de Nêutron de Boro/instrumentação , Boro/efeitos da radiação , Resinas Epóxi/química , Raios gama , Nêutrons , Radiometria/instrumentação , Materiais Restauradores do Canal Radicular/química , Prata/química , Titânio/química , Bismuto/efeitos da radiação , Boro/química , Resinas Epóxi/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Isótopos/química , Isótopos/efeitos da radiação , Dosagem Radioterapêutica , Materiais Restauradores do Canal Radicular/efeitos da radiação , Espalhamento de Radiação , Prata/efeitos da radiação , Análise Espaço-Temporal , Titânio/efeitos da radiação
6.
Appl Radiat Isot ; 88: 238-42, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24387907

RESUMO

A compact Liquid-Lithium Target (LiLiT) was built and tested with a high-power electron gun at Soreq Nuclear Research Center (SNRC). The target is intended to demonstrate liquid-lithium target capabilities to constitute an accelerator-based intense neutron source for Boron Neutron Capture Therapy (BNCT) in hospitals. The lithium target will produce neutrons through the (7)Li(p,n)(7)Be reaction and it will overcome the major problem of removing the thermal power >5kW generated by high-intensity proton beams, necessary for sufficient therapeutic neutron flux. In preliminary experiments liquid lithium was flown through the target loop and generated a stable jet on the concave supporting wall. Electron beam irradiation demonstrated that the liquid-lithium target can dissipate electron power densities of more than 4kW/cm(2) and volumetric power density around 2MW/cm(3) at a lithium flow of ~4m/s, while maintaining stable temperature and vacuum conditions. These power densities correspond to a narrow (σ=~2mm) 1.91MeV, 3mA proton beam. A high-intensity proton beam irradiation (1.91-2.5MeV, 2mA) is being commissioned at the SARAF (Soreq Applied Research Accelerator Facility) superconducting linear accelerator. In order to determine the conditions of LiLiT proton irradiation for BNCT and to tailor the neutron energy spectrum, a characterization of near threshold (~1.91MeV) (7)Li(p,n) neutrons is in progress based on Monte-Carlo (MCNP and Geant4) simulation and on low-intensity experiments with solid LiF targets. In-phantom dosimetry measurements are performed using special designed dosimeters based on CR-39 track detectors.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Lítio/efeitos da radiação , Modelos Estatísticos , Nêutrons , Aceleradores de Partículas/instrumentação , Radioterapia de Alta Energia/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Isótopos/química , Isótopos/efeitos da radiação , Lítio/química , Radiometria , Dosagem Radioterapêutica , Radioterapia de Alta Energia/métodos , Espalhamento de Radiação , Soluções
7.
Appl Radiat Isot ; 88: 243-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24326311

RESUMO

In this work we review all the available experimental neutron data for the (7)Li(p,n) reaction near threshold which is necessary to obtain an accurate source model for Monte Carlo simulations in Boron Neutron Capture Therapy. Scattered published experimental results such as cross sections, differential neutron yields and total yields were collected and analyzed, exploring the sensitivity of the fitting parameters to the different possible variables and deriving a consistent working set of parameters to evaluate the neutron source near threshold.


Assuntos
Berílio/efeitos da radiação , Terapia por Captura de Nêutron de Boro/instrumentação , Lítio/efeitos da radiação , Modelos Estatísticos , Aceleradores de Partículas/instrumentação , Berílio/química , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Isótopos/química , Isótopos/efeitos da radiação , Lítio/química , Nêutrons , Radiometria , Dosagem Radioterapêutica
8.
Appl Radiat Isot ; 85: 39-44, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24374071

RESUMO

In this study, we discuss producing radioisotopes using linear electron accelerators and address production and separation issues of photoneutron (γ,n) and photoproton (γ,p) reactions. While (γ,n) reactions typically result in greater yields, separating product nuclides from the target is challenging since the chemical properties of both are the same. Yields of (γ,p) reactions are typically lower than (γ,n) ones, however they have the advantage that target and product nuclides belong to different chemical species so their separation is often not such an intricate problem. In this paper we consider two examples, (100)Mo(γ,n)(99)Mo and (68)Zn(γ,p)(67)Cu, of photonuclear reactions. Monte-Carlo simulations of the yields are benchmarked with experimental data obtained at the Idaho Accelerator Center using a 44MeV linear electron accelerator. We propose using a kinematic recoil method for photoneutron production. This technique requires (100)Mo target material to be in the form of nanoparticles coated with a catcher material. During irradiation, (99)Mo atoms recoil and get trapped in the coating layer. After irradiation, the coating is dissolved and (99)Mo is collected. At the same time, (100)Mo nanoparticles can be reused. For the photoproduction method, (67)Cu can be separated from the target nuclides, (68)Zn, using standard exchange chromatography methods. Monte-Carlo simulations were performed and the (99)Mo activity was predicted to be about 7MBq/(g(⁎)kW(⁎)h) while (67)Cu activity was predicted to be about 1MBq/(g(⁎)kW(⁎)h). Experimental data confirm the predicted activity for both cases which proves that photonuclear reactions can be used to produce radioisotopes. Lists of medical isotopes which might be obtained using photonuclear reactions have been compiled and are included as well.


Assuntos
Aceleradores de Partículas , Radioisótopos/isolamento & purificação , Compostos Radiofarmacêuticos/isolamento & purificação , Humanos , Isótopos/química , Isótopos/efeitos da radiação , Nanopartículas Metálicas/química , Nanopartículas Metálicas/efeitos da radiação , Molibdênio/isolamento & purificação , Molibdênio/uso terapêutico , Método de Monte Carlo , Nêutrons , Prótons , Radioisótopos/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico
9.
Appl Radiat Isot ; 88: 233-7, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24345525

RESUMO

Within the framework of accelerator-based BNCT, a project to develop a folded Tandem-ElectroStatic-Quadrupole accelerator is under way at the Atomic Energy Commission of Argentina. The proposed accelerator is conceived to deliver a proton beam of 30mA at about 2.5MeV. In this work we explore a Beam Shaping Assembly (BSA) design based on the (7)Li(p,n)(7)Be neutron production reaction to obtain neutron beams to treat deep seated tumors.


Assuntos
Berílio/efeitos da radiação , Terapia por Captura de Nêutron de Boro/instrumentação , Lítio/efeitos da radiação , Modelos Estatísticos , Aceleradores de Partículas/instrumentação , Berílio/química , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Isótopos/química , Isótopos/efeitos da radiação , Lítio/química , Radiometria , Dosagem Radioterapêutica
10.
Appl Radiat Isot ; 77: 115-29, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23583886

RESUMO

The consistency of the published values for fission averaged cross-sections of threshold reactions induced in a nuclear reactor is analyzed. The influence of the literature data involved in the determination of these cross-sections is discussed. Renormalizations based on cross-sections value for the standard reactions, isotopic abundances of the precursors and radiation emission probabilities of the radionuclide under study and the monitor, are applied to the evaluation of the cross-sections for the reactions: (46)Ti(n,p)(46)Sc; (47)Ti(n,p)(47)Sc; (48)Ti(n,p)(48)Sc; and (64)Zn(n,p)(64)Cu.


Assuntos
Radioisótopos de Cobre/química , Nêutrons , Fissão Nuclear , Radiometria/métodos , Escândio/química , Titânio/química , Radioisótopos de Zinco/química , Radioisótopos de Cobre/efeitos da radiação , Isótopos/química , Isótopos/efeitos da radiação , Doses de Radiação , Escândio/efeitos da radiação , Titânio/efeitos da radiação , Radioisótopos de Zinco/efeitos da radiação
11.
Appl Radiat Isot ; 77: 130-8, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23608597

RESUMO

The characterization of a liquid scintillator incorporating an aqueous solution of enriched lithium chloride to produce a scintillator with 0.40% (6)Li is presented, including the performance of the scintillator in terms of its optical properties and neutron response. The scintillator was incorporated into a fast neutron spectrometer, and the light output spectra from 2.5 MeV, 14.1 MeV, and (252)Cf neutrons were measured using capture-gated coincidence techniques. The spectrometer was operated without coincidence to perform thermal neutron measurements. Possible improvements in spectrometer performance are discussed.


Assuntos
Lítio/química , Lítio/efeitos da radiação , Nêutrons , Compostos Orgânicos/química , Contagem de Cintilação/instrumentação , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Isótopos/química , Isótopos/efeitos da radiação , Doses de Radiação , Soluções
12.
Opt Express ; 21(4): 5107-16, 2013 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-23482045

RESUMO

We have theoretically studied the effect of nuclear mass on electron localization in dissociating H2⁺ and its isotopes subjected to a few-cycle 3-µm pulse. Our results reveal an anomalous isotopic effect in which the degree of electron-directed reactivity can be even higher for heavier isotopes in the intense midinfrared field. We show, for the first time, the pronounced electron localization can be established through the interferences among the multi-photon coupling channels. Due to the relative enhancement of higher-order coupling channels with growing mass, the interference maxima at different kinetic energy of the spectra gradually become in phase, ultimately resulting in the larger dissociation asymmetries of heavier isotopes.


Assuntos
Elétrons , Hidrogênio/química , Raios Infravermelhos , Isótopos/química , Modelos Químicos , Fótons , Anisotropia , Simulação por Computador , Hidrogênio/efeitos da radiação , Isótopos/efeitos da radiação
13.
Appl Radiat Isot ; 70(1): 88-98, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21996672

RESUMO

A theoretical study of the nuclear-reaction cross sections for proton-induced reactions on (63)Cu and (65)Cu was performed in the proton energy range from threshold values up to 50MeV. The produced nuclei were different isotopes of Zn, Cu, Ni, Co and Mn, some of which have important applications. The reaction cross-section calculations were performed using the ALICE-IPPE code, which depends on the pre-equilibrium compound nucleus model. This code is suitable for the studied energy and isotopic mass ranges. Approximately 14 excitation functions for the different reactions have been constructed from the calculated cross-section values. The excitation function curves for the proton reactions with natural copper targets have been constructed from those for enriched targets using the natural abundance of the copper isotopes. Comparisons between the calculated excitation functions with those previously experimentally measured are given whenever the experimental values were available. Some statistical parameters were introduced to control the quality of the fitting between both the experimental and the theoretical calculated cross-section values.


Assuntos
Cobre/química , Cobre/efeitos da radiação , Isótopos/química , Isótopos/efeitos da radiação , Modelos Químicos , Software , Simulação por Computador , Relação Dose-Resposta à Radiação , Doses de Radiação
14.
Appl Radiat Isot ; 68(9): 1760-73, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20338771

RESUMO

Cross-section data for the production of medically important radionuclide (124)I via five proton and deuteron induced reactions on enriched tellurium isotopes were evaluated. The nuclear model codes, STAPRE, EMPIRE and TALYS, were used for consistency checks of the experimental data. Recommended excitation functions were derived using a well-defined statistical procedure. Therefrom integral yields were calculated. The various production routes of (124)I were compared. Presently the (124)Te(p,n)(124)I reaction is the method of choice; however, the (125)Te(p,2n)(124)I reaction also appears to have great potential.


Assuntos
Radioisótopos do Iodo/química , Modelos Químicos , Software , Telúrio/química , Telúrio/efeitos da radiação , Simulação por Computador , Elétrons , Radioisótopos do Iodo/efeitos da radiação , Marcação por Isótopo/métodos , Isótopos/química , Isótopos/isolamento & purificação , Isótopos/efeitos da radiação , Prótons , Telúrio/isolamento & purificação
15.
Appl Radiat Isot ; 68(2): 250-5, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19932028

RESUMO

(167)Tm (T(1/2)=9.25d) is a candidate radioisotope for medical therapy and diagnostics due to its Auger-electron and low-energy X- and gamma-ray emission. Excitation functions of the (167)Er(p,n)(167)Tm reaction and (168)Er(p,n)(168)Tm, (167)Er(p,2n)(166)Tm, (166)Er(p,2n)(165)Tm disturbing reactions were measured up to 15MeV by using the stacked foil irradiation technique and gamma-ray spectroscopy. The measured excitation functions agree well with the results of ALICE-IPPE, EMPIRE-II and TALYS nuclear reaction model codes. The thick target yield of (167)Tm in the 15-8MeV energy range is 6.9MBq/microAh. A short comparison of charged particle production routes of (167)Tm is given.


Assuntos
Érbio/química , Isótopos/química , Modelos Químicos , Compostos Radiofarmacêuticos/síntese química , Túlio/química , Simulação por Computador , Érbio/efeitos da radiação , Isótopos/efeitos da radiação , Fótons , Radioisótopos , Compostos Radiofarmacêuticos/efeitos da radiação , Túlio/efeitos da radiação
16.
Appl Radiat Isot ; 66(10): 1488-91, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18468910

RESUMO

Cross sections for (n, 2n), (n, p) and (n, alpha) reactions on the osmium isotopes were measured in the neutron energies 13.5-14.8 MeV by the activation technique with the monitor reaction (93)Nb(n, 2n)(92 m)Nb. Our measurements were carried out by gamma-detection using a coaxial high-purity germanium (HPGe) detector. Natural high-purity osmium powder (99.9%) was fabricated as the samples. The neutron energies were determined by the cross-section ratios for (93)Nb(n, 2n)(92 m)Nb and (90)Zr(n, 2n)(89 m+g)Zr reactions. The fast neutrons were produced by the T(d, n)(4)He reaction. The results obtained were compared with previous data.


Assuntos
Isótopos/química , Isótopos/efeitos da radiação , Osmio/química , Osmio/efeitos da radiação , Relação Dose-Resposta à Radiação , Nêutrons , Doses de Radiação
17.
Radiat Prot Dosimetry ; 126(1-4): 376-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17616546

RESUMO

Characteristics of a (6)Li-loaded neutron coincidence spectrometer were investigated from both measurements and Monte Carlo simulations. The spectrometer consists of three (6)Li-glass scintillators embedded in a liquid organic scintillator BC-501A, which can detect selectively neutrons that deposit the total energy in the BC-501A using a coincidence signal generated from the capture event of thermalised neutrons in the (6)Li-glass scintillators. The relative efficiency and the energy response were measured using 4.7, 7.2 and 9.0 MeV monoenergetic neutrons. The measured ones were compared with the Monte Carlo calculations performed by combining the neutron transport code PHITS and the scintillator response calculation code SCINFUL. The experimental light output spectra were in good agreement with the calculated ones in shape. The energy dependence of the detection efficiency was reproduced by the calculation. The response matrices for 1-10 MeV neutrons were finally obtained.


Assuntos
Isótopos/efeitos da radiação , Lítio/efeitos da radiação , Nêutrons , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Appl Radiat Isot ; 64(8): 910-4, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16713274

RESUMO

The cross sections for the reactions (115)In(n, p)(115g)Cd, (115)In(n, alpha)(112)Ag, (115)In(n, 2n)(114m)In, (113)In(n, 2n)(112m)In, (115)In(n, n')(115m)In, and (113)In(n, n')(113m)In induced by 14 MeV neutrons have been measured by activation relative to the (27)Al(n, alpha)(24)Na. Measurements were carried out by gamma-detection using a coaxial HPGe detector. As samples, natural indium has been used. The fast neutrons were produced by the T(d, n)(4)He reaction. The results obtained are compared with existing data.


Assuntos
Nêutrons Rápidos , Índio/química , Índio/efeitos da radiação , Radiometria/métodos , Relação Dose-Resposta à Radiação , Isótopos/química , Isótopos/efeitos da radiação , Transferência Linear de Energia , Doses de Radiação
19.
Radiat Prot Dosimetry ; 116(1-4 Pt 2): 585-91, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16604705

RESUMO

The independent and cumulative measured yields of residual products in thin lead and bismuth targets irradiated with 0.04-2.6 GeV protons are compared with results by the LAHET, CEM03, LAQGSM03, INCL+ABLA, CASCADE and YIELDX codes, in order to evaluate the predictive power of the codes in this energy region. We found that the predictive power of the tested codes is different but is satisfactory for most of the nuclides in the spallation region, though none of the codes agree well with the data in the whole-mass region of product nuclides and all should be improved further. On the whole, the predictive power of all codes for the data in the fission and fragmentation product regions and, especially, at the borders between spallation and fission and between fission and fragmentation regions is much worse than in the spallation region; therefore, development of better evaporation/fission/fragmentation models is of first priority.


Assuntos
Bismuto/química , Bismuto/efeitos da radiação , Chumbo/química , Chumbo/efeitos da radiação , Modelos Químicos , Fissão Nuclear , Software , Simulação por Computador , Relação Dose-Resposta à Radiação , Isótopos/química , Isótopos/efeitos da radiação , Doses de Radiação , Validação de Programas de Computador
20.
Radiat Prot Dosimetry ; 110(1-4): 255-61, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15353655

RESUMO

A phoswitch-type detector has been developed for monitoring neutron doses in high-energy accelerator facilities. The detector is composed of a liquid organic scintillator (BC501A) coupled with ZnS(Ag) sheets doped with 6Li. The dose from neutrons with energies above 1 MeV is evaluated from the light output spectrum of the BC501A by applying the G-function, which relates the spectrum to the neutron dose directly. The dose from lower energy neutrons, on the other hand, is estimated from the number of scintillations emitted from the ZnS(Ag) sheets. Characteristics of the phoswitch-type detector were studied experimentally in some neutron fields. It was found from the experiments that the detector has an excellent property of pulse-shape discrimination between the scintillations of BC501A and the ZnS(Ag) sheets. The experimental results also indicate that the detector is capable of reproducing doses from thermal neutrons as well as neutrons with energies from one to several tens of megaelectronvolts (MeV).


Assuntos
Nêutrons , Exposição Ocupacional/análise , Proteção Radiológica/instrumentação , Radioisótopos/análise , Radiometria/instrumentação , Contagem de Cintilação/métodos , Transdutores , Exposição Ambiental/análise , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Isótopos/efeitos da radiação , Transferência Linear de Energia , Lítio/efeitos da radiação , Compostos Orgânicos/efeitos da radiação , Doses de Radiação , Proteção Radiológica/métodos , Radiometria/métodos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Soluções , Sulfetos/efeitos da radiação , Compostos de Zinco/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...