Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
1.
Sci Total Environ ; 939: 173447, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-38788942

RESUMO

Transmission of airborne infectious diseases poses great risk for public health and socio-economic stability, thus, there is a need for an effective control method targeting the spread and transmission of pathogenic aerosols. The existence of chemically-reductive trace air contaminants in animal agriculture may affect the oxidation inactivation process of pathogens. In this study, we report how the presence of such gasses impacts the effectiveness of using non-thermal plasma (NTP) within a packed-bed dielectric barrier discharge reactor to inactivate MS2 bacteriophage. Inactivation of the aerosolized bacteriophage is determined by the combination of viability and polymerase chain reaction assays. Using a plasma power source with a voltage of 20 kV and frequency of 350 Hz, after differentiating and excluding the physical removal effects of viral aerosols potentially caused by plasma, the baseline inactivation of MS2 aerosol in air has been determined based on an overall air flow rate of 200 Liters per minute and plasma discharge power of 1.8 W. When either ammonia or hydrogen sulfide gas is introduced into the airstream at a concentration of 1 part per million, the NTP virus inactivation efficiency is reduced to around 0.5-log from the 1-log baseline inactivation in air alone. Higher concentrations of those gasses will not further inhibit the effectiveness of plasma inactivation.


Assuntos
Microbiologia do Ar , Gases em Plasma , Inativação de Vírus , Inativação de Vírus/efeitos dos fármacos , Aerossóis , Levivirus/efeitos dos fármacos , Poluentes Atmosféricos
2.
Int J Biol Macromol ; 272(Pt 2): 132772, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38821299

RESUMO

Bacteria and virus infections have posed a great threat to public health and personnel safety. For realizing rapid sterilization of the bacteria and virus, electrical stimulation sterilization was adopted to endow cellulose fibers with instantaneous antibacterial and antiviral properties. In the proposed strategy, the fiber is fluffed by mechanical refining, and then by means of the hydrogen bond between hydroxyl and aniline, the polyaniline (PANI) directionally grows vertically along the fine fibers via in-situ oxidative polymerization. Benefiting from the conductive polyaniline nanorod arrays on the fiber stem, the paper made from PANI modified refined fibers (PANI/BCF/P) exhibited excellent antibacterial and antiviral activity, the inhibition rates against S. aureus, E. coli, and bacteriophage MS2 can up to 100 %, 100 %, and 99.89 %, respectively when a weak voltage (2.5 V) was applied within 20 min. This study provides a feasible path for plant fiber to achieve efficient antibacterial and antiviral activity with electrical stimulation, which is of great significance for the preparation of electroactive antibacterial and antiviral green health products.


Assuntos
Compostos de Anilina , Antibacterianos , Celulose , Compostos de Anilina/química , Compostos de Anilina/farmacologia , Celulose/química , Celulose/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Estimulação Elétrica , Esterilização/métodos , Antivirais/química , Antivirais/farmacologia , Escherichia coli/efeitos dos fármacos , Escherichia coli/crescimento & desenvolvimento , Staphylococcus aureus/efeitos dos fármacos , Levivirus/efeitos dos fármacos
3.
Photochem Photobiol Sci ; 23(6): 1179-1194, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38771468

RESUMO

In this study, photostability and photodynamic antimicrobial performance of dye extracts from Hibiscus sabdariffa (HS) calyces, Sorghum bicolor (SB) leaf sheaths, Lawsonia inermis (LI) leaves and Curcuma longa (CL) roots were investigated in Acetate-HCl (AH) Buffer (pH 4.6), Tris Base-HCl (TBH) Buffer (pH 8.6), distilled water (dH2O), and Phosphate Buffer Saline (PBS, pH 7.2) using Bacillus subtilis as model for gram positive bacteria, Escherichia coli as model for gram negative bacteria, phage MS2 as model for non-envelope viruses and phage phi6 as model for envelope viruses including SARS CoV-2 which is the causative agent of COVID-19. Our results showed that the photostability of the dye extracts is in the decreasing order of LI > CL > SB > HS. The dye extract-HS is photostable in dH2O but bleaches in buffers-AH, TBH and PBS. The rate of bleaching is higher in AH compared to in TBH and PBS. The bleaching and buffers affected the photodynamic and non-photodynamic antimicrobial activity of the dye extracts. The photodynamic antibacterial activity of the dye extracts is in the decreasing order of CL > HS > LI > SB while the non-photodynamic antibacterial activity is in the decreasing order of LI > CL > HS > SB. The non-photodynamic antiviral activity pattern observed is the same as that of non-photodynamic antibacterial activity observed. However, the photodynamic antiviral activity of the dye extracts is in the decreasing order of CL > LI > HS > SB. Given their performance, the dye extracts maybe mostly suitable for environmental applications including fresh produce and food disinfection, sanitation of hands and contact surfaces where water can serve as diluent for the extracts and the microenvironment is free of salts.


Assuntos
Extratos Vegetais , Extratos Vegetais/química , Extratos Vegetais/farmacologia , Sorghum/química , Hibiscus/química , Curcuma/química , Escherichia coli/efeitos dos fármacos , Levivirus/efeitos dos fármacos , Fármacos Fotossensibilizantes/farmacologia , Fármacos Fotossensibilizantes/química , Bacillus subtilis/efeitos dos fármacos , Desinfecção , Antibacterianos/farmacologia , Antibacterianos/química , SARS-CoV-2/efeitos dos fármacos , Testes de Sensibilidade Microbiana , Corantes/química , Corantes/farmacologia , COVID-19 , Folhas de Planta/química , Anti-Infecciosos/farmacologia , Anti-Infecciosos/química , Luz
4.
Environ Sci Process Impacts ; 26(5): 824-831, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38323647

RESUMO

The control of viruses in water is critical to preventing the spread of infectious viral diseases. Many oxidants can inactivate viruses, and this study aims to systematically compare the disinfection effects of ozone (O3), peroxymonosulfate (PMS), and hydrogen peroxide (H2O2) on MS2 coliphage. The effects of oxidant dose and contact time on disinfection were explored, as were the disinfection effects of three oxidizing agents in secondary effluent. The 4-log inactivation of MS2 coliphage required 0.05 mM O3, 0.5 mM PMS, or 25 mM H2O2 with a contact time of 30 min. All three oxidants achieved at least 4-log disinfection within 30 min, and O3 required only 0.5 min. In secondary effluent, all three oxidants also achieved 4-log inactivation of MS2 coliphage. Excitation-emission matrix (EEM) results indicate that all three oxidants removed dissolved organic matter synchronously and O3 oxidized dissolved organic matter more thoroughly while maintaining disinfection efficacy. Considering the criteria of oxidant dose, contact time, and disinfection efficacy in secondary effluent, O3 is the best choice for MS2 coliphage disinfection among the three oxidants.


Assuntos
Desinfecção , Peróxido de Hidrogênio , Levivirus , Ozônio , Peróxidos , Purificação da Água , Ozônio/química , Ozônio/farmacologia , Desinfecção/métodos , Levivirus/efeitos dos fármacos , Peróxidos/química , Purificação da Água/métodos , Microbiologia da Água , Desinfetantes/farmacologia , Oxidantes/farmacologia , Oxidantes/química
5.
J Appl Microbiol ; 130(5): 1531-1545, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33025608

RESUMO

AIMS: The efficacy of a novel photochemical method for generating chlorine dioxide (photoClO2 ) was evaluated against human noroviruses (HuNoV) surrogate, bacteriophage MS2, and Clostridium difficile endospores. METHODS AND RESULTS: Chlorine dioxide was generated by mixing 1% sodium chlorite with 10 parts-per-million (ppm) Eosin Y and irradiating with a photo-activator-excitable light. PhotoClO2 efficacy was assessed against bacteriophage MS2 and C. difficile endospores in suspension, on hard surfaces and greenhouse conditions under soiled and unsoiled conditions. The estimated effective photoClO2 produced and consumed was 20·39 ± 0·16 ppm at a rate of 8·16 ppm per min in a 1% sodium chlorite solution. In suspension, MS2 phage was reduced by 3·35 and >5·10 log10 PFU per ml in 120 and 90 min, with and without soil, respectively. At the same time, when dried on stainless steel surface, MS2 phage was reduced by >4·53 log10 PFU per carrier in 30 min under both conditions. On the other hand, C. difficile endospores in suspension were reduced by 2·26 and 3·65 log10 CFU per ml in 120 min with and without soiling, respectively. However, on stainless steel surface, maximal reductions of the C. difficile endospores were 0·8 and 1·5 log10 CFU per carrier with and without soiling, respectively, and a maximal reduction of 2·97 log10 CFU per carrier under greenhouse conditions at 24 h. CONCLUSIONS: Overall, photoClO2 showed promise as a technology to control HuNoV contamination on environmental surfaces but requires further optimization and testing against C. difficile endospores. SIGNIFICANCE AND IMPACT OF THE STUDY: Results from this investigation will serve as a model for how to generate and quantify photoClO2 and how to appropriately evaluate this new class of disinfectants against environmentally resilient pathogens: viruses and bacterial endospores.


Assuntos
Compostos Clorados/farmacologia , Clostridioides difficile/efeitos dos fármacos , Desinfetantes/farmacologia , Contaminação de Equipamentos/prevenção & controle , Levivirus/efeitos dos fármacos , Óxidos/farmacologia , Humanos , Norovirus/efeitos dos fármacos , Fotoquímica , Esporos Bacterianos/efeitos dos fármacos , Aço Inoxidável
6.
Am J Trop Med Hyg ; 103(6): 2584-2590, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33073749

RESUMO

Open defecation remains a common practice in developing countries and leads to high incidence and prevalence of acute gastroenteritis, which is most often caused by human noroviruses (human NoV). Encouraging the use of toilets and pit latrines is one method of improving sanitation; however, it is often hindered by not only cultural traditions but also from a reluctance to use latrines and toilets due to their odor and impression of uncleanliness. In an effort to establish new means to encourage toilet and latrine use, laboratory experiments tested the ability of hypochlorous acid (HOCl) to modify the malodorous compounds identified in the air in latrines in developing countries (indole, p-cresol, dimethyl disulfide (DMDS), dimethyl trisulfide (DMTS), and butyric acid) and inactivate MS2 bacteriophage, a surrogate for human NoV. After 5 minutes, > 94% of indole, p-cresol, DMDS, and DMTS was modified as determined by high-pressure liquid chromatography in the presence of 100 ppm HOCl. A log10 reduction value (LRV) greater than 6 was seen for MS2 bacteriophage after 5 minutes of exposure to 100 ppm HOCl in solution. Sensory studies indicated that there was a significant difference (P ≤ 0.05) between the untreated and HOCl-treated samples for all five malodorous compounds tested. The findings suggest that introduction of HOCl into the headspace air could encourage latrine and toilet use. Optimization of HOCl dosing in air to accomplish both odor control and reduction of infectious hazards is worthy of further study.


Assuntos
Controle de Doenças Transmissíveis/métodos , Ácido Hipocloroso , Odorantes , Oxidantes , Banheiros , Escherichia coli/efeitos dos fármacos , Humanos , Levivirus/efeitos dos fármacos , Saneamento/métodos
7.
J Hazard Mater ; 393: 122266, 2020 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-32126420

RESUMO

Porcine reproductive and respiratory syndrome virus (PRRSv) is one of the most significant airborne viruses impacting the pork industry in the US. Non-thermal plasmas (NTPs) are electrical discharges comprised of reactive radicals and excited species that inactivate viruses and bacteria. Our previous experiments using a packed bed NTP reactor demonstrated effective inactivation of bacteriophage MS2 as a function of applied voltage and power. The present study examined the effectiveness of the same reactor in inactivating aerosolized PRRSv. A PRRSv solution containing ∼105 TCID50/ml of PRRSv VR2332 strain was aerosolized at 3 ml/min by an air-jet nebulizer and introduced into 5 or 12 cfm air flow followed by NTP exposure in the reactor. Twin impingers upstream and downstream of the reactor collected samples of the virus-laden air flow for subsequent TCID50 assay and qPCR analyses. An optical particle sizer measured upstream and downstream aerosol size distributions, giving estimates of aerosol filtration by the reactor. The results showed that PRRSv was inactivated to a similar degree as MS2 at the same conditions, with the maximum 1.3-log inactivation of PRRSv achieved at 20 kV and 12 cfm air flow rate. The results demonstrate the potential of properly optimized NTPs in controlling PRRSv transmission.


Assuntos
Gases em Plasma/farmacologia , Vírus da Síndrome Respiratória e Reprodutiva Suína/efeitos dos fármacos , Aerossóis/química , Microbiologia do Ar , Levivirus/efeitos dos fármacos
8.
Artigo em Inglês | MEDLINE | ID: mdl-31615027

RESUMO

Although metal contact is known to reduce bacterial growth, the effects of physical barriers and electricity need further investigation. This study examined the bacteria-reducing properties of copper and stainless-steel metal plates with an added electrical current and up to three filter layers on the growth of Escherichia coli (bacteria) and MS2 bacteriophages (virus). When used with a stainless-steel plate, electricity increased bacteria reduction by 39.5 ± 2.30% in comparison with no electricity added, whereas a three-layer physical barrier decreased its efficiency. Copper also reduced the growth of bacteria, by 58.2 ± 8.23%, and the addition of electricity reduced it further (79.5 ± 2.34%). Bacteriophages were also affected by the metal contact. Further experiments showed that MS2 was also reduced by copper, to 82.9 ± 4.5% after 24 h at 37 °C.


Assuntos
Cobre/farmacologia , Eletricidade , Escherichia coli/efeitos dos fármacos , Levivirus/efeitos dos fármacos , Aço Inoxidável/farmacologia , Metais/farmacologia
9.
J Appl Microbiol ; 127(5): 1315-1326, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31379024

RESUMO

AIMS: (i) To develop an analytical method for recovery and quantification of bacteriophage MS2-as a surrogate for foot-and-mouth disease virus-from complex porous surfaces, with and without the presence of laboratory-developed agricultural grime; (ii) to evaluate, with a 4-log dynamic range, the virucidal activity of common biocides for their ability to decontaminate surfaces and hence remediate facilities, following a foreign animal disease contamination incident. METHODS AND RESULTS: An analytical method was developed and optimized for MS2 recovery from simulated agricultural surfaces. The addition of Dey-Engley neutralizing broth to an extraction buffer improved MS2 viability in liquid extracts, with optimal analytical holding times determined as <8 to ≤24 h, depending on matrix. The recovery of MS2 from surface materials decreased in the order: nonporous reference material >grimed porous materials >nongrimed porous materials. In disinfectant testing, two spray applications of pAB were effective against MS2 (≥4-log reduction) on all operational-scale materials. Two per cent citric acid had limited effectiveness, with a ≥4-log reduction observed on a selected subset of grimed concrete samples. CONCLUSIONS: Decontamination efficacy test results can be affected by surface characteristics, extraction buffer composition, analytical holding time and surface-specific organism survivability. Efficacy should be evaluated using a test method that reflects the environmental characteristics of the intended application. SIGNIFICANCE AND IMPACT OF THE STUDY: The results of this study demonstrate the importance of analytical method verification tests for disinfectant testing prior to application in complex environments.


Assuntos
Descontaminação/métodos , Desinfetantes/farmacologia , Levivirus/efeitos dos fármacos , Agricultura , Desinfetantes/administração & dosagem , Levivirus/fisiologia , Viabilidade Microbiana/efeitos dos fármacos , Porosidade , Solo
10.
Sci Total Environ ; 670: 1140-1145, 2019 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-31018430

RESUMO

Fate and transport of carbon nanomaterials can be strongly dependent on the interaction with secondary particulates in the aquatic systems. Bio-particulates in water, e.g., viruses with charged and hydrophobic surface moieties, may profoundly influence the interfacial behavior and hence the environmental fate of nanomaterials (and vice versa). This study systematically evaluates the interfacial interaction of acid-functionalized multiwalled carbon nanotubes (MWNTs) with MS2 bacteriophages, or heteroaggregation behavior of these particulates, under mono- and di-valent cations and with Suwannee River humic acid (SRHA). Results indicate that the highest concentration of MS2 (i.e., MWNT:MS2 of 100:1) renders exceptional stability of MWNTs, even in high salinity conditions. However, at lower MS2 concentrations (i.e., MWNT:MS2 of 1000:1 and 10,000:1), the suppression of MWNT heteroaggregation rate is not as significant. The observed enhanced stability is likely caused by the preferential attachment of the MS2 capsids onto MWNT surfaces, which is mediated by electrostatic attraction (between negatively charged oxygen-containing moieties on MWNTs and positively charged amino acid residues on MS2 surfaces) and/or by MS2 capsids with positive hydropathy index (indicating strong hydrophobicity). Presence of SRHA also shows stability enhancement; however, at lower MS2 concentrations, SRHA dominated the heteroaggregation behavior. These results implicate that preferential interaction between virus capsids (i.e., MS2 and may be other waterborne viruses) and carbonaceous nanomaterials may influence environmental transport of both in aquatic environments.


Assuntos
Substâncias Húmicas/análise , Levivirus/efeitos dos fármacos , Nanotubos de Carbono/efeitos adversos , Rios/química , Poluentes Químicos da Água/efeitos adversos , Florida
11.
Chemosphere ; 214: 195-202, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30265926

RESUMO

We determined the potential interference of extracellular algal organic matter (EAOM) and intracellular algal organic matter (IAOM) extracted from Microcystis aeruginosa on MS2 bacteriophage inactivation under UV irradiation at two wavelengths (220 and 254 nm). UV irradiation at 220 nm doubled the inactivation rate of MS2 in water containing EAOM than in organic-free phosphate buffered solution. In contrast, EAOM did not change MS2 inactivation by exposure to UV 254 nm. The presence of IAOM did not significantly influence MS2 inactivation by exposure to either UV 254 or UV 220 nm. To achieve 3 log10 inactivation of MS2, UV254 nm required more than double the dose of UV220 nm (45 mJ/cm2 vs. 20 mJ/cm2). Linear correlations between the reduction in infectivity and the reduction in genome copies detected by reverse transcription quantitative polymerase chain reaction suggested that genomic damage is the main mechanism responsible for MS2 inactivation in water containing algal organic matter (AOM) by exposure to UV irradiation. These findings suggest that the presence of AOM did not negatively influence MS2 inactivation by either 220 or 254 nm irradiation, and that a lower UV dose of 220 nm irradiation can be used to achieve the same level of inactivation in water containing AOM.


Assuntos
Levivirus/efeitos da radiação , Microcystis/química , Raios Ultravioleta , Inativação de Vírus , Relação Dose-Resposta à Radiação , Genoma Viral/efeitos da radiação , Levivirus/efeitos dos fármacos , Purificação da Água/métodos
12.
Int J Food Microbiol ; 291: 67-71, 2019 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-30472396

RESUMO

Foodborne illnesses caused by norovirus contaminated fresh produce remain a food safety concern worldwide. In the present study, the impacts of commercial and home processing conditions of strawberries were evaluated for inactivation of the MS2 bacteriophage. MS2 was used as a surrogate of norovirus and was spot inoculated onto strawberries to achieve 6.6 log PFU/g. The inoculated strawberries were washed with tap water, electrolyzed water, or 50 ppm chlorine for 90 s prior to and after storage. After initial washing, the strawberries were separately stored at -20 °C and -80 °C for 30 days. Change in MS2 populations on strawberries was evaluated by plaque assay method on day 1, 15, and 30 for -20 °C and -80 °C groups. The results showed that washing strawberries prior to storage resulted in a significant decrease (approximately 1 log PFU/g) of MS2 population regardless of the treatment (p < 0.05). Frozen storage had minor effects on inactivating MS2, which resulted in approximately a 0.5 log PFU/g reduction at the end of storage. Washing frozen berries in electrolyzed water or 50 ppm chlorine on day 30 resulted in an additional 1 log PFU/g decrease in MS2 compared to water alone. These results suggest that washing strawberries with a chemical antimicrobial prior to and post frozen storage may enhance microbial safety.


Assuntos
Anti-Infecciosos/farmacologia , Manipulação de Alimentos/métodos , Microbiologia de Alimentos/métodos , Fragaria/virologia , Levivirus/efeitos dos fármacos , Água/química , Cloro/farmacologia , Desinfetantes/farmacologia , Manipulação de Alimentos/normas , Congelamento , Frutas/microbiologia , Levivirus/fisiologia , Viabilidade Microbiana/efeitos dos fármacos , Radioisótopos/farmacologia
13.
Water Environ Res ; 90(7): 623-633, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30188279

RESUMO

A series of full-scale testing was performed at the City of Lathrop Consolidated Treatment Facility to determine the "concentration times time" (Ct) value for free chlorine disinfection of nitrified membrane bioreactor (MBR) effluent to achieve more than 5-log virus inactivation. The full-scale testing consisted of tracer study, chlorine decay study, and virus seeding study. The virus seeding study was performed at a flow rate of 1 million gal/d (3800 m3/min), which corresponded to a theoretical contact time of 117 minutes in the chlorine contact basin. It was found that Ct values as small as 3 mg·min/L were sufficient to achieve 5-log inactivation of MS2 bacteriophage in this study, which is comparable to the results of previous bench- and pilot-scale free chlorine disinfection studies on nitrified MBR effluent (3 to 40 mg·min/L), as well as those of pilot- and full-scale studies on granular media-filtered nitrified effluent (2 to 22 mg·min/L).


Assuntos
Cloro/farmacologia , Desinfecção/métodos , Inativação de Vírus/efeitos dos fármacos , Purificação da Água/métodos , Reatores Biológicos , California , Cloro/química , Levivirus/efeitos dos fármacos , Projetos Piloto , Reciclagem , Microbiologia da Água , Purificação da Água/instrumentação
14.
Int J Hyg Environ Health ; 221(8): 1124-1132, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30098909

RESUMO

New disinfection procedures are being developed and proposed for use in drinking-water production. Authorising their use requires an effective test strategy that can simulate conditions in practice. For this purpose, we developed a test rig working in a flow-through mode similar to the disinfection procedures in waterworks, but under tightly defined conditions, including very short contact times. To quantify the influence of DOC, temperature and pH on the efficacy of two standard disinfectants, chlorine and chlorine dioxide, simulated use tests were systematically performed. This test rig enabled quantitative comparison of the reduction of four test organisms, two viruses and two bacteria, in response to disinfection. Chlorine was substantially more effective against Enterococcus faecium than chlorine dioxide whereas the latter was more effective against the bacteriophage MS2, especially at pH values of >7.5 at which chlorine efficacies already decline. Contrary to expectation, bacteria were not generally reduced more quickly than viruses. Overall, the results confirm a high efficacy of chlorine and chlorine dioxide, validating them as standard disinfectants for assessing the efficacy of new disinfectants. Furthermore, these data demonstrate that the test rig is an appropriate tool for testing new disinfectants as well as disinfection procedures.


Assuntos
Compostos Clorados/farmacologia , Cloro/farmacologia , Desinfetantes/farmacologia , Desinfecção/métodos , Água Potável/microbiologia , Óxidos/farmacologia , Purificação da Água/métodos , Bacteriófago PRD1/efeitos dos fármacos , Bacteriófago PRD1/crescimento & desenvolvimento , Carbono/análise , Enterococcus faecium/efeitos dos fármacos , Enterococcus faecium/crescimento & desenvolvimento , Escherichia coli/efeitos dos fármacos , Escherichia coli/crescimento & desenvolvimento , Concentração de Íons de Hidrogênio , Levivirus/efeitos dos fármacos , Levivirus/crescimento & desenvolvimento , Temperatura
15.
Appl Environ Microbiol ; 84(17)2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29915117

RESUMO

Viruses cause serious pathogenic contamination that severely affects the environment and human health. Cold atmospheric-pressure plasma efficiently inactivates pathogenic bacteria; however, the mechanism of virus inactivation by plasma is not fully understood. In this study, surface plasma in argon mixed with 1% air and plasma-activated water was used to treat water containing bacteriophages. Both agents efficiently inactivated bacteriophages T4, Φ174, and MS2 in a time-dependent manner. Prolonged storage had marginal effects on the antiviral activity of plasma-activated water. DNA and protein analysis revealed that the reactive species generated by plasma damaged both nucleic acids and proteins, consistent with the morphological examination showing that plasma treatment caused the aggregation of bacteriophages. The inactivation of bacteriophages was alleviated by the singlet oxygen scavengers, demonstrating that singlet oxygen played a primary role in this process. Our findings provide a potentially effective disinfecting strategy to combat the environmental viruses using cold atmospheric-pressure plasma and plasma-activated water.IMPORTANCE Contamination with pathogenic and infectious viruses severely threatens human health and animal husbandry. Current methods for disinfection have different disadvantages, such as inconvenience and contamination of disinfection by-products (e.g., chlorine disinfection). In this study, atmospheric surface plasma in argon mixed with air and plasma-activated water was found to efficiently inactivate bacteriophages, and plasma-activated water still had strong antiviral activity after prolonged storage. Furthermore, it was shown that bacteriophage inactivation was associated with damage to nucleic acids and proteins by singlet oxygen. An understanding of the biological effects of plasma-based treatment is useful to inform the development of plasma into a novel disinfecting strategy with convenience and no by-product.


Assuntos
Argônio/farmacologia , Bacteriófago T4/efeitos dos fármacos , Desinfecção/métodos , Levivirus/efeitos dos fármacos , Gases em Plasma/farmacologia , Inativação de Vírus/efeitos dos fármacos , Ácidos Nucleicos/química , Oxigênio Singlete/química , Proteínas Virais/química
16.
FEMS Microbiol Ecol ; 94(8)2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29878194

RESUMO

Enteric viruses and bacteriophages are exposed to various inactivating factors outside their host, and among them chlorine and heat are the most commonly used sanitizer in water industry and treatment in the food industry, respectively. Using MS2 phages as models for enteric viruses, we investigated the impact of free chlorine and heat on their physicochemical properties. Free chlorine was first evaluated alone. No increase in either capsid permeability or hydrophobicity was observed. The negative surface charge slightly increased suggesting molecular changes in the capsid. However, a weakening of the capsid by chlorine was suggested by differential scanning fluorimetry. This phenomenon was confirmed when chlorination was followed by a heat treatment. Indeed, an increase in the inactivation of MS2 phages and the permeability of their capsids to RNases was observed. More interestingly, an increase in the expression of hydrophobic domains at the phage surface was observed, but only for phages remaining infectious. The chlorine-caused weakening of the capsid suggested that, for an optimal use, the oxidant should be followed by heat. The increased permeability to RNases and the expression of hydrophobic domains may contribute to the development or improvement of molecular methods specific for infectious enteric viruses.


Assuntos
Capsídeo/fisiologia , Cloro/farmacologia , Temperatura Alta , Levivirus/efeitos dos fármacos , Levivirus/fisiologia , Fluorometria , Genoma Viral/genética , Halogenação , Interações Hidrofóbicas e Hidrofílicas , Levivirus/genética
17.
Colloids Surf B Biointerfaces ; 165: 293-302, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29501024

RESUMO

An improved hot bubble column evaporator (HBCE) was used to study virus inactivation rates using hot bubble-virus interactions in two different conditions: (1) using the bubble coalescence inhibition phenomenon of monovalent electrolytes and (2) with reducing the electrostatic repulsive forces between virus and bubble, by the addition of divalent electrolytes. It is shown that the continuous flow of (dry) air, even at 150-250 °C, only heats the aqueous solution in the bubble column to about 45°-55 °C and it was also established that viruses are not significantly affected by even long term exposure to this solution temperature, as confirmed separately from water bath experiments. Hence, the effects observed appeared to be caused entirely by collisions between the hot air bubbles and the virus organisms. It was also established that the use of high air inlet temperatures, for short periods of time, can reduce the thermal energy requirement to only about 25% (about 114 kJ/L) of that required for boiling (about 450 kJ/L).


Assuntos
Ar/análise , Cloreto de Cálcio/farmacologia , Levivirus/efeitos dos fármacos , Cloreto de Sódio/farmacologia , Vapor/análise , Inativação de Vírus/efeitos dos fármacos , Eletrólitos/farmacologia , Temperatura Alta , Levivirus/fisiologia , Nebulizadores e Vaporizadores , Eletricidade Estática , Termodinâmica , Volatilização
18.
Am J Infect Control ; 46(5): 507-511, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29305284

RESUMO

BACKGROUND: Past studies have shown that infectious aerosols created during toilet flushing result in surface contamination of the restroom. The goals of this study were to quantify viral contamination of surfaces in restrooms after flushing and the impact of disinfectants added to the toilet bowl prior to flushing on reducing surface contamination. METHODS: The degree of contamination of surfaces in the restroom was assessed with and without the addition of coliphage MS2 to the toilet bowl before flushing. The bowl water and various surfaces in the restroom were subsequently tested for the presence of the virus. RESULTS: The toilet bowl rim, toilet seat top, and toilet seat underside were contaminated in all trials without a disinfectant added to the bowl water before flushing. All disinfectants significantly reduced concentrations on surfaces when the contact time was ≥15 minutes. Hydrogen peroxide resulted in very little reduction of virus in the toilet bowl (<1 log10). Peracetic acid and quaternary ammonium had the greatest log reductions on virus in the organic matter in the toilet. CONCLUSIONS: Toilet flushing resulted in extensive contamination of surfaces within the restroom. Addition of disinfectant to the toilet bowl prior to flushing reduced the level of contamination in the bowl and fomites after flushing.


Assuntos
Aparelho Sanitário , Desinfetantes/farmacologia , Desinfecção/métodos , Microbiologia Ambiental , Levivirus/efeitos dos fármacos , Levivirus/isolamento & purificação , Hospitais , Humanos , Peróxido de Hidrogênio/farmacologia , Ácido Peracético/farmacologia , Compostos de Amônio Quaternário/farmacologia
19.
Colloids Surf B Biointerfaces ; 162: 179-185, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29190469

RESUMO

The inactivation efficacy of bacteriophage MS2 by simulated sunlight irradiation was investigated to understand the effects of MS2 aggregation and adsorption to particles in solutions with different components. Kaolinite and Microcystis aeruginosa were used as model inorganic and organic particles, respectively. Lower pH and di-valent ions (Ca2+) were main factors on the aggregation and inactivation of MS2. In the presence of both particles, there was no significant impact on the MS2 inactivation efficacy by kaolinite (10-200mM) or Microcystis aeruginosa (102-105Cells/mL) in 1mM NaCl at pH 7. However at lower pH 3, MS2 aggregates formed in the particle-free and kaolinite-containing solutions, caused lower inactivation since the outer viruses of aggregation protect the inner viruses. In addition, more MS2 adsorbed on Microcystis aeruginosa at lower pH (3 and 4). Microcystis aeruginosa would act as a potential photosensitizer for ROS production to inactivate the adsorbed MS2, since extracellular organic matter (EOM) of Microcystis aeruginosa was detected in this study, which has been reported to produce ROS under solar irradiation. At pH 7, Na+ had no effect on the inactivation of MS2, because MS2 was stable and dispersed even at 200mM Na+. MS2 aggregated and adsorbed on particles even at 10mM Ca2+ and led to lower inactivation. Kaolinite cannot offer enough protection to adsorbed MS2 as aggregation and Microcystis aeruginosa acts as potential photosensitizer to produce ROS and inactivate the adsorbed MS2 at high concentration of Ca2+. In particle-free solution, SRNOM inhibited MS2 inactivation by shielding the sunlight and coating MS2 to increase its survival.


Assuntos
Levivirus/efeitos dos fármacos , Microcystis/química , Fármacos Fotossensibilizantes/farmacologia , Espécies Reativas de Oxigênio/agonistas , Cloreto de Sódio/farmacologia , Inativação de Vírus/efeitos dos fármacos , Adsorção , Aderência Bacteriana , Cálcio/metabolismo , Concentração de Íons de Hidrogênio , Caulim/química , Levivirus/efeitos da radiação , Microcystis/efeitos da radiação , Fármacos Fotossensibilizantes/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Luz Solar , Inativação de Vírus/efeitos da radiação
20.
Environ Sci Pollut Res Int ; 25(28): 27676-27692, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29255985

RESUMO

Over the last years, the photo-Fenton process has been established as an effective, green alternative to chemical disinfection of waters and wastewaters. Microorganisms' inactivation is the latest success story in the application of this process at near-neutral pH, albeit without clearly elucidated inactivation mechanisms. In this review, the main pathways of the combined photo-Fenton process against the most frequent pathogen models (Escherichia coli for bacteria and MS2 bacteriophage for viruses) are analyzed. Firstly, the action of solar light is described and the specific inactivation mechanisms in bacteria (internal photo-Fenton) and viruses (genome damage) are presented. The contribution of the external pathways due to the potential presence of organic matter in generating reactive oxygen species (ROS) and their effects on microorganism inactivation are discussed. Afterwards, the effects of the gradual addition of Fe and H2O2 are assessed and the differences among bacterial and viral inactivation are highlighted. As a final step, the simultaneous addition of both reagents induces the photo-Fenton in the bulk, focusing on the differences induced by the homogeneous or heterogeneous fraction of the process and the variation among the two respective targets. This work exploits the accumulated evidence on the mechanisms of bacterial inactivation and the scarce ones towards viral targets, aiming to bridge this knowledge gap and make possible the further application of the photo-Fenton process in the field of water/wastewater treatment.


Assuntos
Desinfecção/métodos , Peróxido de Hidrogênio/química , Ferro/química , Luz Solar , Águas Residuárias , Purificação da Água/métodos , Escherichia coli/efeitos dos fármacos , Escherichia coli/efeitos da radiação , Concentração de Íons de Hidrogênio , Levivirus/efeitos dos fármacos , Levivirus/efeitos da radiação , Oxirredução , Águas Residuárias/microbiologia , Águas Residuárias/virologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...