Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 17.306
Filtrar
1.
J Vis ; 24(7): 2, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38953860

RESUMO

Bayesian adaptive methods for sensory threshold determination were conceived originally to track a single threshold. When applied to the testing of vision, they do not exploit the spatial patterns that underlie thresholds at different locations in the visual field. Exploiting these patterns has been recognized as key to further improving visual field test efficiency. We present a new approach (TORONTO) that outperforms other existing methods in terms of speed and accuracy. TORONTO generalizes the QUEST/ZEST algorithm to estimate simultaneously multiple thresholds. After each trial, without waiting for a fully determined threshold, the trial-oriented approach updates not only the location currently tested but also all other locations based on patterns in a reference data set. Since the availability of reference data can be limited, techniques are developed to overcome this limitation. TORONTO was evaluated using computer-simulated visual field tests: In the reliable condition (false positive [FP] = false negative [FN] = 3%), the median termination and root mean square error (RMSE) of TORONTO was 153 trials and 2.0 dB, twice as fast with equal accuracy as ZEST. In the FP = FN = 15% condition, TORONTO terminated in 151 trials and was 2.2 times faster than ZEST with better RMSE (2.6 vs. 3.7 dB). In the FP = FN = 30% condition, TORONTO achieved 4.2 dB RMSE in 148 trials, while all other techniques had > 6.5 dB RMSE and terminated much slower. In conclusion, TORONTO is a fast and accurate algorithm for determining multiple thresholds under a wide range of reliability and subject conditions.


Assuntos
Algoritmos , Psicometria , Limiar Sensorial , Humanos , Psicometria/métodos , Psicometria/normas , Limiar Sensorial/fisiologia , Testes de Campo Visual/métodos , Campos Visuais/fisiologia , Teorema de Bayes , Simulação por Computador , Reprodutibilidade dos Testes
2.
J Texture Stud ; 55(4): e12849, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38961563

RESUMO

While taste and smell perception have been thoroughly investigated, our understanding of oral somatosensory perception remains limited. Further, assessing and measuring individual differences in oral somatosensory perception pose notable challenges. This review aimed to evaluate the existing methods to assess oral somatosensory perception by examining and comparing the strengths and limitations of each method. The review highlighted the lack of standardized assessment methods and the various procedures within each method. Tactile sensitivity can be assessed using several methods, but each method measures different tactile dimensions. Further investigations are needed to confirm its correlation with texture sensitivity. In addition, measuring a single textural attribute may not provide an overall representation of texture sensitivity. Thermal sensitivity can be evaluated using thermal-change detection or temperature discrimination tests. The chemesthetic sensitivity tests involve either localized or whole-mouth stimulation tests. The choice of an appropriate method for assessing oral somatosensory sensitivity depends on several factors, including the specific research objectives and the target population. Each method has its unique intended purpose, strengths, and limitations, so no universally superior approach exists. To overcome some of the limitations associated with certain methods, the review offers alternative or complementary approaches that could be considered. Researchers can enhance the comprehensive assessment of oral somatosensory sensitivity by carefully selecting and potentially combining methods. In addition, a standardized protocol remains necessary for each method.


Assuntos
Boca , Percepção do Tato , Humanos , Percepção do Tato/fisiologia , Boca/fisiologia , Individualidade , Percepção Gustatória/fisiologia , Tato/fisiologia , Paladar/fisiologia , Limiar Sensorial/fisiologia , Olfato/fisiologia , Sensação Térmica/fisiologia
3.
J Headache Pain ; 25(1): 111, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38982389

RESUMO

BACKGROUND: Pediatric headache is an increasing medical problem that has adverse effects on children's quality of life, academic performance, and social functioning. Children with primary headaches exhibit enhanced sensory sensitivity compared to their healthy peers. However, comprehensive investigations including multimodal sensory sensitivity assessment are lacking. This study aimed to compare sensory sensitivity of children with primary headaches with their healthy peers across multiple sensory domains. METHODS: The study included 172 participants aged 6 to 17 years (M = 13.09, SD = 3.02 years; 120 girls). Of these 80 participants were patients with migraine, 23 were patients with tension-type headache, and 69 were healthy controls. The following sensory measures were obtained: Mechanical Detection Threshold (MDT), Mechanical Pain Threshold (MPT), Mechanical Pain Sensitivity (MPS), detection and pain threshold for Transcutaneous Electrical Nerve Stimulation (TENS), olfactory and intranasal trigeminal detection threshold, and odor identification ability. Sensory sensitivity was compared between groups with a series of Kruskal-Wallis tests. Binomial regression models were used to compare the relative utility of sensory sensitivity measures in classifying participants into patients and healthy controls, as well as into patients with migraine and tension-type headache. RESULTS: Patients with migraine had lower MPT measured at the forearm than patients with tension-type headaches and healthy controls. MPS was higher in patients with migraine than in healthy controls. All patients with headaches had lower detection threshold of TENS and higher olfactory sensitivity. Healthy controls showed increased intranasal trigeminal sensitivity. Scores in MPS, TENS, and olfactory and trigeminal thresholds were significantly predicting presence of primary headaches. Additionally, scores in MPT, olfactory and trigeminal threshold were positive predictors of type of headache. CONCLUSIONS: Children with primary headaches exhibit different sensory profiles than healthy controls. The obtained results suggest presence of increased overall, multimodal sensitivity in children with primary headaches, what may negatively impact daily functioning and contribute to further pain chronification. TRIAL REGISTRATION: The study was registered in the German Registry of Clinical Trials (DRKS) DRKS00021062.


Assuntos
Transtornos de Enxaqueca , Limiar da Dor , Cefaleia do Tipo Tensional , Humanos , Adolescente , Feminino , Masculino , Criança , Cefaleia do Tipo Tensional/fisiopatologia , Cefaleia do Tipo Tensional/diagnóstico , Transtornos de Enxaqueca/fisiopatologia , Transtornos de Enxaqueca/diagnóstico , Limiar da Dor/fisiologia , Limiar Sensorial/fisiologia , Transtornos da Cefaleia Primários/fisiopatologia , Transtornos da Cefaleia Primários/diagnóstico
4.
BMJ Open ; 14(6): e082193, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38862223

RESUMO

INTRODUCTION: Diabetic neuropathy is frequently underdiagnosed and undertreated. Logistic problems accompany the routine use of the biothesiometer. Hence, we attempted to find a more easily available alternative. RESEARCH DESIGN AND METHODS: 149 patients with diabetes visiting the outpatient endocrinology clinic were assessed for vibration sense using a 128-Hz tuning fork (absolute timing method) and a biothesiometer. A reading of >25 V on the biothesiometer (known as vibration perception threshold or VPT) was taken as the diagnostic criterion for severe neuropathy while >15 V was used as an indicator of the mild form. The sensitivity and specificity were calculated by constructing the receiver operating characteristic curve (ROC). A p value of <0.05 was considered as statistically significant. RESULTS: The timed tuning fork (TTF) test showed a statistically significant correlation with the VPT measurements (r=-0.5, p=0.000). Using the VPT findings as a reference, a timed tuning fork cut-off of 4.8 s was 76% sensitive and 77% specific in diagnosing mild neuropathy while absent tuning fork sensation demonstrated 70% sensitivity and 90% specificity in detecting severe neuropathy. CONCLUSIONS: The tuning fork test demonstrated significant sensitivity and specificity in diagnosing diabetic peripheral neuropathy when compared against the biothesiometer. A cut-off of 4.8 s can be a useful indicator of the early stages of onset of the condition.


Assuntos
Neuropatias Diabéticas , Sensibilidade e Especificidade , Limiar Sensorial , Centros de Atenção Terciária , Vibração , Humanos , Neuropatias Diabéticas/diagnóstico , Neuropatias Diabéticas/fisiopatologia , Estudos Transversais , Índia , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Curva ROC , Programas de Rastreamento/métodos , Programas de Rastreamento/instrumentação
5.
Proc Natl Acad Sci U S A ; 121(25): e2312293121, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38857385

RESUMO

The perception of sensory attributes is often quantified through measurements of sensitivity (the ability to detect small stimulus changes), as well as through direct judgments of appearance or intensity. Despite their ubiquity, the relationship between these two measurements remains controversial and unresolved. Here, we propose a framework in which they arise from different aspects of a common representation. Specifically, we assume that judgments of stimulus intensity (e.g., as measured through rating scales) reflect the mean value of an internal representation, and sensitivity reflects a combination of mean value and noise properties, as quantified by the statistical measure of Fisher information. Unique identification of these internal representation properties can be achieved by combining measurements of sensitivity and judgments of intensity. As a central example, we show that Weber's law of perceptual sensitivity can coexist with Stevens' power-law scaling of intensity ratings (for all exponents), when the noise amplitude increases in proportion to the representational mean. We then extend this result beyond the Weber's law range by incorporating a more general and physiology-inspired form of noise and show that the combination of noise properties and sensitivity measurements accurately predicts intensity ratings across a variety of sensory modalities and attributes. Our framework unifies two primary perceptual measurements-thresholds for sensitivity and rating scales for intensity-and provides a neural interpretation for the underlying representation.


Assuntos
Percepção , Humanos , Percepção/fisiologia , Limiar Sensorial/fisiologia , Sensação/fisiologia , Julgamento/fisiologia
6.
Occup Environ Med ; 81(6): 302-307, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38871449

RESUMO

OBJECTIVE: Examine sensory function of the upper airway in four groups of subjects recruited from the World Trade Centre General Responder Cohort (WTCGRC), with/without obstructive sleep apnoea (OSA), and with/without chronic rhinosinusitis (CRS). METHODS: Upper airway sensory function was determined using 2-point discrimination (2-PD) and vibration threshold (VT) in 163 WTCGRC subjects with both OSA and CRS (cases), OSA or CRS alone and without OSA or CRS (controls). Presence of OSA was determined from clinical sleep studies or home sleep testing. Presence of CRS was determined by nasal symptom questionnaire. The relationship between the presence of OSA and CRS and upper airway sensory impairment was assessed using linear regression analysis with each of 2PD and VT sensory threshold values as the dependent variable; OSA, CRS and their interaction were the independent variables. Age, gender and body mass index were covariates in the statistical model. The primary analysis was comparison of OSA+CRS versus controls (no OSA and no CRS) evaluated by linear contrasts. RESULTS: There were no differences in 2-PD or VT in those with OSA+CRS, OSA and CRS alone or controls. However, both 2-PD and VT were significantly higher in the WTCGRC controls compared with values seen in historical controls using the same methodology (median 2-PD 13.0; CI (11.0 to 13.5) vs 10.5; CI (8 to 11); VT: mean±SEM (9.3±0.6 vs 2.2±0.1)). CONCLUSION: While no differences were found in upper airway sensation between cases of OSA and CRS versus controls in the WTGRC population, there was evidence of impaired upper airway sensation in the WTGRC overall.


Assuntos
Rinite , Ataques Terroristas de 11 de Setembro , Sinusite , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/complicações , Masculino , Sinusite/fisiopatologia , Sinusite/complicações , Feminino , Rinite/fisiopatologia , Rinite/complicações , Pessoa de Meia-Idade , Adulto , Doença Crônica , Socorristas/estatística & dados numéricos , Doenças Profissionais/etiologia , Doenças Profissionais/epidemiologia , Doenças Profissionais/fisiopatologia , Limiar Sensorial/fisiologia , Rinossinusite
7.
Front Endocrinol (Lausanne) ; 15: 1357294, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38872969

RESUMO

Objective: To investigate the correlation between vibration sensory threshold (VPT) and renal function, including glomerulus and renal tubule, in patients with type 2 diabetes mellitus (T2DM). Methods: A total of 1274 patients with T2DM who were enrolled in the Department of Endocrinology of the First Affiliated Hospital of Fujian Medical University between January 2017 and June 2020 were included. Patients were grouped according to VPT levels and divided into three groups, including the normal VPT group (VPT<15V), the mild-moderate elevated VPT group (VPT15~25V), and the severely elevated VPT group (VPT≥25 V). Linear correlation analysis was used to analyze the correlation between VPT and renal functions, including glomerulus markers urine microalbumin (MA) and urinary immunoglobulin G (U-IgG), and renal tubule marker α1-microglobulin (α1-MG). Chronic kidney disease (CKD) was defined according to Kidney Disease Improving Global Outcomes (KDIGO) criteria. The binary logistic regression of the relation between VPT and CKD, eGFR<60 ml/min, and UACR >30 mg/g were expressed. Results: In the mild-moderate and severely elevated VPT group, injury biomarkers of glomerulus (MA and U-IgG), renal tubule (α1-MG), and the incidence of CKD, eGFR<60 ml/min, and UACR > 30 mg/g were gradually increased compared with the normal VPT group. Furthermore, patients with diabetes and severely elevated VPT had significantly higher levels of MA (ß=197.54, p=0.042) and α1-MG (ß=11.69, p=0.023) compared to those with normal VPT. Also, patients with mild-moderate elevated VPT demonstrate significantly higher levels of MA (ß=229.02, p=0.005). Patients in mild-moderate elevated VPT group (OR=1.463, 95% CI 1.005-2.127; OR=1.816, 95% CI 1.212-2.721) and severely elevated VPT group (OR=1.704, 95% CI 1.113-2.611; OR=2.027, 95% CI 1.248-3.294) are at a higher incidence of CKD and elevated levels of UACR>30mg/g compared to those in the VPT normal group. Moreover, the incidence of positive Upro was notably higher in the severely elevated VPT group (OR=1.738, 95% CI 1.182-2.556). However, this phenomenon was not observed in the incidence of eGFR <60 ml/min. Conclusion: A higher VPT is positively associated with the incidence of CKD in patients with T2DM, particularly with elevated UACR. VPT may serve as a marker for glomerulus and renal tubule injury.


Assuntos
Diabetes Mellitus Tipo 2 , Limiar Sensorial , Vibração , Humanos , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/fisiopatologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Limiar Sensorial/fisiologia , Taxa de Filtração Glomerular , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/epidemiologia , Nefropatias Diabéticas/fisiopatologia , Nefropatias Diabéticas/etiologia , Nefropatias Diabéticas/epidemiologia , Adulto , Testes de Função Renal , Túbulos Renais/fisiopatologia , Rim/fisiopatologia
9.
Brain Stimul ; 17(3): 668-675, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38740182

RESUMO

BACKGROUND: Virtually everyone is exposed to power-frequency MF (50/60 Hz), inducing in our body electric fields and currents, potentially modulating brain function. MF-induced electric fields within the central nervous system can generate flickering visual perceptions (magnetophosphenes), which form the basis of international MF exposure guidelines and recommendations protecting workers and the general public. However, magnetophosphene perception thresholds were estimated 40 years ago in a small, unreplicated study with significant uncertainties and leaving open the question of the involved interaction site. METHODS: We used a stimulation modality termed transcranial alternating magnetic stimulation (tAMS), delivering in situ sinusoidal electric fields comparable to transcranial alternating current stimulation (tACS). Magnetophosphene perception was quantified in 81 volunteers exposed to MF (eye or occipital exposure) between 0 and 50 mT at frequencies of 20, 50, 60 and 100 Hz. RESULTS: Reliable magnetophosphene perception was induced with tAMS without any scalp sensation, a major advantage as compared to tACS. Frequency-dependent thresholds were quantified using binary logistic regressions hence allowing to establish condition dependent probabilities of perception. Results support an interaction between induced current density and retinal rod cells. CONCLUSION: Beyond fundamental and immediate implications for international safety guidelines, and for identifying the interaction site underlying phosphene perception (ubiquitous in tACS experiments), our results support exploring the potential of tAMS for the differential diagnosis of retinal disorders and neuromodulation therapy.


Assuntos
Fosfenos , Estimulação Magnética Transcraniana , Percepção Visual , Humanos , Masculino , Adulto , Feminino , Fosfenos/fisiologia , Estimulação Magnética Transcraniana/métodos , Percepção Visual/fisiologia , Adulto Jovem , Limiar Sensorial/fisiologia , Campos Magnéticos , Pessoa de Meia-Idade
10.
Artigo em Inglês | MEDLINE | ID: mdl-38692474

RESUMO

Transcranial magnetic stimulation (TMS) is commonly delivered at an intensity defined by the resting motor threshold (rMT), which is thought to represent cortical excitability, even if the TMS target area falls outside of the motor cortex. This approach rests on the assumption that cortical excitability, as measured through the motor cortex, represents a 'global' measure of excitability. Another common approach to measure cortical excitability relies on the phosphene threshold (PT), measured through the visual cortex of the brain. However, it remains unclear whether either estimate can serve as a singular measure to infer cortical excitability across different brain regions. If PT and rMT can indeed be used to infer cortical excitability across brain regions, they should be correlated. To test this, we systematically identified previous studies that measured PT and rMT to calculate an overall correlation between the two estimates. Our results, based on 16 effect sizes from eight studies, indicated that PT and rMT are correlated (ρ = 0.4), and thus one measure could potentially serve as a measure to infer cortical excitability across brain regions. Three exploratory meta-analyses revealed that the strength of the correlation is affected by different methodologies, and that PT intensities are higher than rMT. Evidence for a PT-rMT correlation remained robust across all analyses. Further research is necessary for an in-depth understanding of how cortical excitability is reflected through TMS.


Assuntos
Córtex Motor , Fosfenos , Estimulação Magnética Transcraniana , Estimulação Magnética Transcraniana/métodos , Humanos , Fosfenos/fisiologia , Córtex Motor/fisiologia , Potencial Evocado Motor/fisiologia , Limiar Sensorial/fisiologia , Excitabilidade Cortical/fisiologia
11.
Mult Scler Relat Disord ; 87: 105690, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38795594

RESUMO

BACKGROUND: Patients with Multiple Sclerosis (PwMS) often experience sensory, balance, and gait problems. Impairment in any sensation may increase imbalance and gait disorder in PwMS. This study aimed to (1) compare foot plantar sensations, knee position sense, balance, and gait in PwMS compared to Healthy Individuals (HI) and (2) examine the relationship between plantar sensations, knee position sense, balance, and gait in PwMS. METHODS: Thirty PwMS with mild disability and 10 HI participated in this study. Light touch threshold, two-point discrimination, vibration duration, and knee position sense were examined on the Dominant Side (DS) and Non-Dominant Side (NDS). Balance and spatio-temporal gait analysis were evaluated in all participants. RESULTS: PwMS had higher postural sway with eyes closed on the foam surface, longer swing phase of DS, longer single support phase of NDS, and shorter double support phase of DS compared to HI (p < 0.05). The results of regression analysis showed that the light touch thresholds of the 1st and 5th toes of the DS were associated with postural sway in different sensory conditions (p < 0.05). In contrast, the light touch thresholds of the 1st and 5th toes, two-point discrimination of the heel, vibration duration of the 1st metatarsal head and knee position sense of the NDS, and light touch threshold in the medial arch of both sides were associated with the gait parameters (p < 0.05). CONCLUSION: PwMS, even with mild disabilities needs neurorehabilitation to improve plantar sensation and knee position sense.


Assuntos
Esclerose Múltipla , Equilíbrio Postural , Humanos , Equilíbrio Postural/fisiologia , Feminino , Masculino , Adulto , Esclerose Múltipla/fisiopatologia , Esclerose Múltipla/complicações , Pessoa de Meia-Idade , Pé/fisiopatologia , Propriocepção/fisiologia , Marcha/fisiologia , Transtornos Neurológicos da Marcha/fisiopatologia , Transtornos Neurológicos da Marcha/etiologia , Joelho/fisiopatologia , Limiar Sensorial/fisiologia , Vibração , Índice de Gravidade de Doença
12.
Vision Res ; 221: 108422, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38718618

RESUMO

We used the psychophysical summation paradigm to reveal some spatial characteristics of the mechanism responsible for detecting a motion-defined visual target in central vision. There has been much previous work on spatial summation for motion detection and direction discrimination, but none has assessed it in terms of the velocity threshold or used velocity noise to provide a measure of the efficiency of the velocity processing mechanism. Motion-defined targets were centered within square fields of randomly selected gray levels. The motion was produced within the disk-shaped target region by shifting the pixels rightwards for 0.2 s. The uniform target motion was perturbed by Gaussian motion noise in horizontal strips of 16 pixels. Independent variables were field size, the diameter of the disk target, and the variance of an independent perturbation added to the (signed) velocity of each 16-pixel strip. The dependent variable was the threshold velocity for target detection. Velocity thresholds formed swoosh-shaped (descending, then ascending) functions of target diameter. Minimum values were obtained when targets subtended approximately 2 degrees of visual angle. The data were fit with a continuum of models, extending from the theoretically ideal observer through various inefficient and noisy refinements thereof. In particular, we introduce the concept of sparse sampling to account for the relative inefficiency of the velocity thresholds. The best fits were obtained from a model observer whose responses were determined by comparing the velocity profile of each stimulus with a limited set of sparsely sampled "DoG" templates, each of which is the product of a random binary array and the difference between two 2-D Gaussian density functions.


Assuntos
Percepção de Movimento , Estimulação Luminosa , Psicofísica , Limiar Sensorial , Humanos , Percepção de Movimento/fisiologia , Limiar Sensorial/fisiologia , Estimulação Luminosa/métodos , Discriminação Psicológica/fisiologia , Percepção Espacial/fisiologia , Adulto
13.
J Vis ; 24(5): 8, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38780934

RESUMO

Perceptual learning is a multifaceted process, encompassing general learning, between-session forgetting or consolidation, and within-session fast relearning and deterioration. The learning curve constructed from threshold estimates in blocks or sessions, based on tens or hundreds of trials, may obscure component processes; high temporal resolution is necessary. We developed two nonparametric inference procedures: a Bayesian inference procedure (BIP) to estimate the posterior distribution of contrast threshold in each learning block for each learner independently and a hierarchical Bayesian model (HBM) that computes the joint posterior distribution of contrast threshold across all learning blocks at the population, subject, and test levels via the covariance of contrast thresholds across blocks. We applied the procedures to the data from two studies that investigated the interaction between feedback and training accuracy in Gabor orientation identification over 1920 trials across six sessions and estimated learning curve with block sizes L = 10, 20, 40, 80, 160, and 320 trials. The HBM generated significantly better fits to the data, smaller standard deviations, and more precise estimates, compared to the BIP across all block sizes. In addition, the HBM generated unbiased estimates, whereas the BIP only generated unbiased estimates with large block sizes but exhibited increased bias with small block sizes. With L = 10, 20, and 40, we were able to consistently identify general learning, between-session forgetting, and rapid relearning and adaptation within sessions. The nonparametric HBM provides a general framework for fine-grained assessment of the learning curve and enables identification of component processes in perceptual learning.


Assuntos
Teorema de Bayes , Aprendizagem , Limiar Sensorial , Humanos , Aprendizagem/fisiologia , Limiar Sensorial/fisiologia , Percepção Visual/fisiologia , Sensibilidades de Contraste/fisiologia , Curva de Aprendizado , Estimulação Luminosa/métodos
14.
Vestn Oftalmol ; 140(2. Vyp. 2): 116-122, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739140

RESUMO

PURPOSE: This study assesses the light sensitivity and its variability in each point of the visual field in patients without glaucoma and with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study involving 500 patients were analyzed. The initial examination of all patients was performed using basic ophthalmological methods, including static perimetry. Retinal light sensitivity and its variability were assessed in 54 points corresponding to the Humphrey 24-2 program. Mean deviation and pattern standard deviation of light sensitivity were calculated for each point. RESULTS: The lowest light sensitivity values in patients with moderate glaucoma were found in the periphery of the nasal sector, at point No. 27 - 14.4 dB, and at points No. 24-26 along the horizontal axis from the nasal side - from 17.7 to 22.7 dB. The maximum variability of light sensitivity was found in the nasal sector on both sides of the horizontal line - from 10.7 to 11.5 dB. The average light sensitivity above the horizontal axis in patients with advanced glaucoma was 10.8 dB, which is 2 dB higher than in the lower half of the visual field - 8.8 dB. The highest light sensitivity values were found at points No. 24 - 17.7 dB and No. 31 - 16.78 dB, the lowest - at point No. 32 - 4.5 dB. The average variability values of light sensitivity in the upper half of the visual field were 9.6 dB, which is 1 dB less than in the lower half of the visual field - 10.6 dB. CONCLUSION: According to our data, points No. 32 and No. 40 are of particular interest in the diagnostic plan. In these loci, the highest light sensitivity values were determined in early and moderate glaucoma. However, the values in these points decrease significantly in advanced glaucoma. It can be assumed that changes in light sensitivity in these loci at the early stages of glaucoma may be a predictor of glaucoma progression.


Assuntos
Glaucoma , Retina , Testes de Campo Visual , Campos Visuais , Humanos , Campos Visuais/fisiologia , Testes de Campo Visual/métodos , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Pessoa de Meia-Idade , Masculino , Feminino , Retina/fisiopatologia , Estudos Prospectivos , Adulto , Luz , Idoso , Limiar Sensorial/fisiologia , Estudos de Casos e Controles , Reprodutibilidade dos Testes
15.
Invest Ophthalmol Vis Sci ; 65(5): 33, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38771569

RESUMO

Purpose: This study explored early (contrast discrimination) and intermediate (global form perception) visual processing in primary subtypes of glaucoma: primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). We aimed to understand early and intermediate visual processing in POAG and PACG, matched for similar visual field defect severity. Methods: Early visual processing was measured using a contrast discrimination task described by Porkorny and Smith (1997), and intermediate processing using a global form perception task using glass pattern coherence thresholds. Thresholds were determined centrally and at a single midperipheral location (12.5°) in a quadrant without visual field defects. Controls were tested in corresponding quadrants to individuals with glaucoma. Results: Sixty participants (20 POAG, 20 PACG, and 20 age-matched controls), aged 50 to 77 years, were included. Visual field defects were matched between POAG and PACG, with mean deviation values of -6.53 ± 4.46 (range: -1.5 to -16.85) dB and -6.2 ± 4.24 (range: -1.37 to -16.42) dB, respectively. Two-Way ANOVA revealed significant differences in thresholds between the glaucoma groups and the control group for both contrast discrimination and global form perception tasks, with higher thresholds in the glaucoma groups. Post hoc analyses showed no significant contrast discrimination difference between POAG and PACG, but POAG had significantly higher thresholds than PACG for form perception. Conclusions: In form perception, POAG showed slightly worse performance than PACG, suggesting that individuals with POAG may experience more severe functional damage than PACG of similar visual field severity.


Assuntos
Sensibilidades de Contraste , Percepção de Forma , Glaucoma de Ângulo Fechado , Glaucoma de Ângulo Aberto , Campos Visuais , Humanos , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Fechado/fisiopatologia , Pessoa de Meia-Idade , Idoso , Masculino , Feminino , Campos Visuais/fisiologia , Sensibilidades de Contraste/fisiologia , Percepção de Forma/fisiologia , Pressão Intraocular/fisiologia , Limiar Sensorial/fisiologia , Testes de Campo Visual
16.
Invest Ophthalmol Vis Sci ; 65(5): 38, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38787547

RESUMO

Purpose: Visual snow is the hallmark of the neurological condition visual snow syndrome (VSS) but the characteristics of the visual snow percept remain poorly defined. This study aimed to quantify its appearance, interobserver variability, and effect on measured visual performance and self-reported visual quality. Methods: Twenty-three participants with VSS estimated their visual snow dot size, separation, luminance, and flicker rate by matching to a simulation. To assess whether visual snow masks vision, we compared pattern discrimination thresholds for textures that were similar in spatial scale to visual snow as well as more coarse than visual snow, in participants with VSS, and with and without external noise simulating visual snow in 23 controls. Results: Mean and 95% confidence intervals for visual snow appearance were: size (6.0, 5.8-6.3 arcseconds), separation (2.0, 1.7-2.3 arcmin), luminance (72.4, 58.1-86.8 cd/m2), and flicker rate (25.8, 18.9-32.8 frames per image at 120 hertz [Hz]). Participants with finer dot spacing estimates also reported greater visibility of their visual snow (τb = -0.41, 95% confidence interval [CI] = -0.62 to -0.13, P = 0.01). In controls, adding simulated fine-scale visual snow to textures increased thresholds for fine but not coarse textures (F(1, 22) = 4.98, P = 0.036, ηp2 = 0.19). In VSS, thresholds for fine and coarse textures were similar (t(22) = 0.54, P = 0.60), suggesting that inherent visual snow does not act like external noise in controls. Conclusions: Our quantitative estimates of visual snow constrain its likely neural origins, may aid differential diagnosis, and inform future investigations of how it affects vision. Methods to quantify visual snow are needed for evaluation of potential treatments.


Assuntos
Acuidade Visual , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Adulto Jovem , Limiar Sensorial/fisiologia , Transtornos da Visão/fisiopatologia , Transtornos da Visão/diagnóstico , Idoso , Percepção Visual/fisiologia , Variações Dependentes do Observador , Reconhecimento Visual de Modelos/fisiologia , Transtornos da Percepção
17.
Laryngoscope ; 134(7): 3277-3285, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38578016

RESUMO

OBJECTIVES: This study aimed to determine the characteristics of patients with qualitative olfactory dysfunction (qualOD) and whether individuals with parosmia exhibit increased olfactory sensitivity to previously reported odorous triggers of parosmia. METHODS: This study included individuals aged ≥18 years, divided into quantitative OD only, parosmia, and phantosmia groups. Data collected included: clinical-demographic data, "Sniffin' Sticks" scores, questionnaires (depression scale, importance of olfaction), and information about parosmia and phantosmia. A proportion of patients underwent trigger odor threshold testing for 2-Furfurylthiol [FFT] found in coffee and 2,6-nonadienal [Nonadienal] found in cucumber. RESULTS: Those with parosmia were typically younger women, with shorter OD duration due to post-viral OD (PVOD), hyposmic/normosmic, and experienced parosmia more severely. Parosmia was 3.5 times more likely in PVOD. Those with phantosmia were older, with longer OD duration due to idiopathic OD, hyposmic/anosmic, and experienced phantosmia less severely. There were no significant differences between FFT and Nonadienal threshold scores in patients with parosmia, phantosmia, or only quantitative OD, but all groups had significantly increased olfactory sensitivity for trigger odors compared to phenyl ethyl alcohol (PEA). CONCLUSION: Parosmia and phantosmia patients have distinct characteristics. This may provide clinicians with a better understanding of possible olfactory outcomes in these patients. The higher olfactory sensitivity of all groups to trigger odors compared to PEA raises interesting points about parosmia triggers and odors in the context of warning for danger, in relation to the pathophysiology of parosmia that may be worth exploring in future studies. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:3277-3285, 2024.


Assuntos
Odorantes , Transtornos do Olfato , Limiar Sensorial , Olfato , Humanos , Feminino , Pessoa de Meia-Idade , Transtornos do Olfato/fisiopatologia , Transtornos do Olfato/etiologia , Adulto , Masculino , Limiar Sensorial/fisiologia , Olfato/fisiologia , Idoso , Aldeídos , Inquéritos e Questionários , Adulto Jovem
18.
Vision Res ; 219: 108394, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38579407

RESUMO

Contour Integration (CI) is the ability to integrate elemental features into objects and is a basic visual process essential for object perception and recognition, and for functioning in visual environments. It is now well documented that people with schizophrenia (SZ), in addition to having cognitive impairments, also have several visual perceptual deficits, including in CI. Here, we retrospectively characterize the performance of both SZ and neurotypical individuals (NT) on a series of contour shapes, made up of Gabor elements, that varied in terms of closure and curvature. Participants in both groups performed a CI training task that included 7 different families of shapes (Lines, Ellipse, Blobs, Squiggles, Spiral, Circle and Letters) for up to 40 sessions. Two parameters were manipulated in the training task: Orientation Jitter (OJ, i.e., orientation deviations of individual Gabor elements from ideal for each shape) and Inducer Number (IN, i.e., number of Gabor elements defining the shape). Results show that both OJ and IN thresholds significantly differed between the groups, with higher (OJ) and lower (IN) thresholds observed in the controls. Furthermore, we found significant effects as a function of the contour shapes, with differences between groups emerging with contours that were considered more complex, e.g., due to having a higher degree of curvature (Blobs, Spiral, Letters). These data can inform future work that aims to characterize visual integration impairments in schizophrenia.


Assuntos
Percepção de Forma , Esquizofrenia , Humanos , Percepção de Forma/fisiologia , Esquizofrenia/fisiopatologia , Adulto , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Limiar Sensorial/fisiologia , Estimulação Luminosa/métodos , Estudos de Casos e Controles , Reconhecimento Visual de Modelos/fisiologia , Adulto Jovem
19.
Neuropsychologia ; 198: 108879, 2024 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-38570111

RESUMO

After stroke, patients can experience visual hypersensitivity, an increase in their sensitivity for visual stimuli as compared to their state prior to the stroke. Candidate behavioural mechanisms for these subjective symptoms are atypical bottom-up sensory processing and impaired selective attention, but empirical evidence is currently lacking. In the current study, we aimed to investigate the relationship between post-stroke visual hypersensitivity and sensory thresholds, sensory processing speed, and selective attention using computational modelling of behavioural data. During a whole/partial report task, participants (51 stroke patients, 76 orthopedic patients, and 77 neurotypical adults) had to correctly identify a single target letter that was presented alone (for 17-100 ms) or along a distractor (for 83ms). Performance on this task was used to estimate the sensory threshold, sensory processing speed, and selective attention abilities of each participant. In the stroke population, both on a group and individual level, there was evidence for impaired selective attention and -to a lesser extent- lower sensory thresholds in patients with post-stroke visual hypersensitivity as compared to neurotypical adults, orthopedic patients, or stroke patients without post-stroke sensory hypersensitivity. These results provide a significant advancement in our comprehension of post-stroke visual hypersensitivity and can serve as a catalyst for further investigations into the underlying mechanisms of sensory hypersensitivity after other types of acquired brain injury as well as post-injury hypersensitivity for other sensory modalities.


Assuntos
Atenção , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/fisiopatologia , Pessoa de Meia-Idade , Atenção/fisiologia , Idoso , Adulto , Limiar Sensorial/fisiologia , Estimulação Luminosa , Percepção Visual/fisiologia
20.
Atten Percept Psychophys ; 86(4): 1417-1434, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38658516

RESUMO

Vestibular perceptual thresholds quantify sensory noise associated with reliable perception of small self-motions. Previous studies have identified substantial variation between even healthy individuals' thresholds. However, it remains unclear if or how an individual's vestibular threshold varies over repeated measures across various time scales (repeated measurements on the same day, across days, weeks, or months). Here, we assessed yaw rotation and roll tilt thresholds in four individuals and compared this intra-individual variability to inter-individual variability of thresholds measured across a large age-matched cohort each measured only once. For analysis, we performed simulations of threshold measurements where there was no underlying variability (or it was manipulated) to compare to that observed empirically. We found remarkable consistency in vestibular thresholds within individuals, for both yaw rotation and roll tilt; this contrasts with substantial inter-individual differences. Thus, we conclude that vestibular perceptual thresholds are an innate characteristic, which validates pooling measures across sessions and potentially serves as a stable clinical diagnostic and/or biomarker.


Assuntos
Limiar Sensorial , Vestíbulo do Labirinto , Humanos , Limiar Sensorial/fisiologia , Masculino , Feminino , Adulto , Vestíbulo do Labirinto/fisiologia , Percepção de Movimento/fisiologia , Rotação , Individualidade , Adulto Jovem , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...