Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.113
Filtrar
1.
J Chromatogr A ; 1728: 464995, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-38805895

RESUMO

Fluorescently labeled antibodies are widely used to visualize the adsorption process in protein chromatography using confocal laser scanning microscopy (CLSM), but also as a tracer for determination of residence time distribution (RTD) in continuous chromatography. It is assumed that the labeled protein is inert and representative of the unlabeled antibody, ignoring the fact that labeling with a fluorescent dye can change the characteristics of the original molecule. It became evident that the fluorescently labeled antibody has a higher affinity toward protein A resins such as MabSelect Sure. This can be due to slight differences in hydrophobicity and net charge, which are caused by the addition of the fluorescent dye. However, this difference is eliminated when using high salt concentrations in the adsorption studies. In this work, the site occupancy of two labeled antibodies, MAb1 (IgG1 subclass) and MAb2 (IgG2 subclass) conjugated with the fluorescent dye Alexa Fluor™ 488 was elucidated by intact mass spectrometry (MS) and peptide mapping LC-MS/MS, employing a sequential cleavage with Endoproteinase Lys-C and trypsin and in parallel with chymotrypsin alone. It was shown that the main binding site for the dye was a specific lysine in the heavy chains of the MAb1 and MAb2 molecules, in positions 188 and 189 respectively. Other lysine residues distributed throughout the protein sequence were labeled to a lot lesser extent. The labeled antibody had a slightly different affinity to MabSelect Sure although its primary binding site (to Protein A) was not affected by labeling, despite the secondary region responsible for binding to the protein A was partly labeled. Overall, the fluorescent-labeled antibodies are a good compromise as an inert tracer in residence time distribution and chromatography studies because they are much cheaper than isotope-labeled antibodies; However, the differences between the labeled and unlabeled antibodies should be considered.


Assuntos
Anticorpos Monoclonais , Corantes Fluorescentes , Proteína Estafilocócica A , Corantes Fluorescentes/química , Proteína Estafilocócica A/química , Proteína Estafilocócica A/metabolismo , Anticorpos Monoclonais/química , Anticorpos Monoclonais/metabolismo , Cromatografia de Afinidade/métodos , Sítios de Ligação , Imunoglobulina G/química , Imunoglobulina G/metabolismo , Espectrometria de Massas em Tandem/métodos , Mapeamento de Peptídeos/métodos , Animais
2.
MAbs ; 16(1): 2341641, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38652517

RESUMO

Peptide mapping with mass spectrometry (MS) is an important tool for protein characterization in the biopharmaceutical industry. Historically, peptide mapping monitors post-translational modifications (PTMs) of protein products and process intermediates during development. Multi-attribute monitoring (MAM) methods have been used previously in commercial release and stability testing panels to ensure control of selected critical quality attributes (CQAs). Our goal is to use MAM methods as part of an overall analytical testing strategy specifically focused on CQAs, while removing or replacing historical separation methods that do not effectively distinguish CQAs from non-CQAs due to co-elution. For example, in this study, we developed a strategy to replace a profile-based ion-exchange chromatography (IEC) method using a MAM method in combination with traditional purity methods to ensure control of charge variant CQAs for a commercial antibody (mAb) drug product (DP). To support this change in commercial testing strategy, the charge variant CQAs were identified and characterized during development by high-resolution LC-MS and LC-MS/MS. The charge variant CQAs included PTMs, high molecular weight species, and low molecular weight species. Thus, removal of the IEC method from the DP specification was achieved using a validated LC-MS MAM method on a QDa system to directly measure the charge variant PTM CQAs in combination with size exclusion chromatography (SE-HPLC) and capillary electrophoresis (CE-SDS) to measure the non-PTM charge variant CQAs. Bridging data between the MAM, IEC, and SE-HPLC methods were included in the commercial marketing application to justify removing IEC from the DP specification. We have also used this MAM method as a test for identity to reduce the number of QC assays. This strategy has received approvals from several health authorities.


Assuntos
Anticorpos Monoclonais , Mapeamento de Peptídeos , Cromatografia por Troca Iônica/métodos , Anticorpos Monoclonais/química , Mapeamento de Peptídeos/métodos , Humanos , Processamento de Proteína Pós-Traducional , Espectrometria de Massas em Tandem/métodos , Controle de Qualidade
3.
J Pharm Biomed Anal ; 243: 116124, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38520959

RESUMO

Peptide mapping is the key method for characterization of primary structure of biotherapeutic proteins. This method relies on digestion of proteins into peptides that are then analyzed for amino acid sequence and post-translational modifications. Owing to its high activity and cleavage specificity, trypsin is the protease of choice for peptide mapping. In this study, we investigated critical requirements of peptide mapping and how trypsin affects these requirements. We found that the commonly used MS-grade trypsins contained non-specific, chymotryptic-like cleavage activity causing generation of semi-tryptic peptides and degradation of tryptic-specific peptides. Furthermore, MS-grade trypsins contained pre-existing autoproteolytic peptides and, moreover, additional autoproteolytic peptides were resulting from prominent autoproteolysis during digestion. In our long-standing quest to improve trypsin performance, we developed novel recombinant trypsin and evaluated whether it could address major trypsin drawbacks in peptide mapping. The study showed that the novel trypsin was free of detectable non-specific cleavage activity, had negligible level of autoproteolysis and maintained high activity over the course of digestion reaction. Taking advantage of the novel trypsin advanced properties, especially high cleavage specificity, we established the application for use of large trypsin quantities to digest proteolytically resistant protein sites without negative side effects. We also tested trypsin/Lys-C mix comprising the novel trypsin and showed elimination of non-specific cleavages observed in the digests with the commonly used trypsins. In addition, the improved features of the novel trypsin allowed us to establish the method for accurate and efficient non-enzymatic PTM analysis in biotherapeutic proteins.


Assuntos
Fragmentos de Peptídeos , Proteínas , Mapeamento de Peptídeos/métodos , Tripsina/química , Fragmentos de Peptídeos/química , Peptídeos/análise
4.
Anal Biochem ; 688: 115475, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38336012

RESUMO

Biosimilars are a cost-effective alternative to biopharmaceuticals, necessitating rigorous analytical methods for consistency and compliance. Liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) is a versatile tool for assessing key attributes, encompassing molecular mass, primary structure, and post-translational modifications (PTMs). Adhering to ICH Q2R1, we validated an LC-HRMS based peptide mapping method using NISTmab as a reference. The method validation parameters, covering system suitability, specificity, accuracy, precision, robustness, and carryover, were comprehensively assessed. The method effectively differentiated the NISTmab from similar counterparts as well as from artificially introduced spiked conditions. Notably, the accuracy of mass error for NISTmab specific complementarity determining region peptides was within a maximum of 2.42 parts per million (ppm) from theoretical and the highest percent relative standard deviation (%RSD) observed for precision was 0.000219 %. It demonstrates precision in sequence coverage and PTM detection, with a visual inspection of total ion chromatogram approach for variability assessment. The method maintains robustness when subjected to diverse storage conditions, encompassing variations in column temperature and mobile phase composition. Negligible carryover was noted during the carryover analysis. In summary, this method serves as a versatile platform for multiple biosimilar development by effectively characterizing and identifying monoclonal antibodies, ultimately ensuring product quality.


Assuntos
Medicamentos Biossimilares , Medicamentos Biossimilares/análise , Medicamentos Biossimilares/química , Anticorpos Monoclonais/química , Espectrometria de Massa com Cromatografia Líquida , Mapeamento de Peptídeos/métodos , Peptídeos
5.
Nat Nanotechnol ; 19(5): 652-659, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38351230

RESUMO

Proteins are the primary functional actors of the cell. While proteoform diversity is known to be highly biologically relevant, current protein analysis methods are of limited use for distinguishing proteoforms. Mass spectrometric methods, in particular, often provide only ambiguous information on post-translational modification sites, and sequences of co-existing modifications may not be resolved. Here we demonstrate fluorescence resonance energy transfer (FRET)-based single-molecule protein fingerprinting to map the location of individual amino acids and post-translational modifications within single full-length protein molecules. Our data show that both intrinsically disordered proteins and folded globular proteins can be fingerprinted with a subnanometer resolution, achieved by probing the amino acids one by one using single-molecule FRET via DNA exchange. This capability was demonstrated through the analysis of alpha-synuclein, an intrinsically disordered protein, by accurately quantifying isoforms in mixtures using a machine learning classifier, and by determining the locations of two O-GlcNAc moieties. Furthermore, we demonstrate fingerprinting of the globular proteins Bcl-2-like protein 1, procalcitonin and S100A9. We anticipate that our ability to perform proteoform identification with the ultimate sensitivity may unlock exciting new venues in proteomics research and biomarker-based diagnosis.


Assuntos
Transferência Ressonante de Energia de Fluorescência , Transferência Ressonante de Energia de Fluorescência/métodos , Humanos , alfa-Sinucleína/química , alfa-Sinucleína/metabolismo , Processamento de Proteína Pós-Traducional , Proteínas Intrinsicamente Desordenadas/química , Imagem Individual de Molécula/métodos , Aprendizado de Máquina , Mapeamento de Peptídeos/métodos
6.
J Pharm Sci ; 113(6): 1498-1505, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38342339

RESUMO

Stop codon readthroughs were examined in 48 recombinant therapeutic protein candidates produced from multiple clones of Chinese hamster ovary cells, using peptide mapping with LC-MS/MS detection. We found that stop codon readthrough is a common phenomenon occurring in most of these candidates, with levels varying from below the detection limit of ∼0.001 % to ∼1 %. The readthrough propensity depends on the stop codon being used, as well as the nucleotides surrounding it. The amino acids misincorporated into the stop position can be well-predicted by a third-base wobble mismatch and a first-base U/G mismatch during codon recognition, i.e., tyrosine or glutamine insertion for the UAA and UAG stop codons, and tryptophan, cysteine or arginine insertion for the UGA stop codon. Data shown in this report demonstrate the importance of optimizing the DNA sequence near the stop codon, and the importance of detecting stop codon readthroughs during the development of a therapeutic product.


Assuntos
Códon de Terminação , Cricetulus , Proteínas Recombinantes , Células CHO , Animais , Códon de Terminação/genética , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Espectrometria de Massas em Tandem , Cricetinae , Mapeamento de Peptídeos/métodos , Biossíntese de Proteínas/genética
7.
J AOAC Int ; 107(1): 177-188, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-37606972

RESUMO

BACKGROUND: Biologics are essential in cancer treatment because they stimulate the body's natural response to fight cancer, but they are expensive. Biosimilars are more affordable compared to patent biologicals, but it must be verified that they are as effective as their innovators. Characterization of biosimilars and assessment of interchangeability requires many data points for verification. OBJECTIVE: The proposed study provides a quality assessment of two new bevacizumab (BVZ) biosimilars, produced by Amgen and Biocad, Inc., through the development and greenness assessment of an orthogonal testing protocol and purity indicating assay, including size-exclusion (SE-HPLC), reversed-phase (RP-HPLC), and cation exchange chromatography (CEX-HPLC) in addition to dynamic light scattering (DLS) and sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). METHODS: SE-HPLC method was performed and validated to screen the BVZ monomer and its aggregates and/or fragments. Peak purity and system suitability parameters were calculated. Results indicate that the orthogonal protocol is a useful tool for assessing monoclonal antibody stability. It is a key criterion for biosimilarity assessment. DLS and SDS-PAGE results were compared to each other to reveal close retention times and banding patterns between BVZ innovator and its biosimilars. These results showed that Avastin® and the investigated biosimilars have the same profile in terms of peak area of related compounds within the acceptance limit and apparent molecular weight, and the SDS-PAGE technique was found to be the most eco-friendly technique among others. CONCLUSIONS: The results obtained highlighted the importance of assessing similarities and differences in ensuring the biosimilarity and interchangeability of the studied products. HIGHLIGHTS: BVZ is one of the essential monoclonal antibodies in the treatment of colorectal cancer (CRC). BVZ biosimilars were evaluated by developing an orthogonal testing protocol and a purity-indicating assay. The size-exclusion (SE)-HPLC method was applied and validated to monitor the BVZ monomer and its aggregates. The results demonstrated the importance of assessing the stability and biosimilarity of BVZ.


Assuntos
Anticorpos Monoclonais , Medicamentos Biossimilares , Anticorpos Monoclonais/química , Bevacizumab , Mapeamento de Peptídeos/métodos , Análise de Componente Principal
8.
Anal Chem ; 95(42): 15514-15521, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37816151

RESUMO

LC-MS based peptide mapping, i.e., proteolytic digestion followed by LC-MS/MS analysis, is the method of choice for protein primary structural characterization. Manual proteolytic digestion is usually a labor-intensive procedure. In this work, a novel method was developed for fully automated online protein digestion and LC-MS peptide mapping. The method generates LC-MS data from undigested protein samples without user intervention by utilizing the same HPLC system that performs the chromatographic separation with some additional modules. Each sample is rapidly digested immediately prior to its LC-MS analysis, minimizing artifacts that can grow over longer digestion times or digest storage times as in manual or automated offline digestion methods. In this report, we implemented the method on an Agilent 1290 Infinity II LC system equipped with a Multisampler. The system performs a complete digestion workflow including denaturation, disulfide reduction, cysteine alkylation, buffer exchange, and tryptic digestion. We demonstrated that the system is capable of digesting monoclonal antibodies and other proteins with excellent efficiency and is robust and reproducible and produces fewer artifacts than manually prepared digests. In addition, it consumes only a few micrograms of material as most of the digested sample protein is subjected to LC-MS analysis.


Assuntos
Peptídeo Hidrolases , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Mapeamento de Peptídeos/métodos , Proteólise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos
9.
Artigo em Inglês | MEDLINE | ID: mdl-37776677

RESUMO

The antiangiogenic drug bevacizumab is a blockbuster therapeutic pharmaceutical product that is used to treat many different types of cancer including kidney, colon, rectum, lung, and breast cancer. As a result, multiple biosimilars have been approved across the various regulatory jurisdictions in India (>20 in number till date). The rapidly growing market and acceptance of biosimilars was the motivation to perform comparability study of bevacizumab biosimilars that are presently available in the Indian market. A comprehensive analytical and functional biosimilarity assessment has been performed to examine and compare innovator product of bevacizumab (Avastin-innovator product, Roche Products (India) Pvt Ltd) and six biosimilars that are being marketed in India (Abevmy from Mylan Pharmaceuticals Pvt Ltd, Bevazza from Lupin Ltd, Bryxta from Zydus Cadila, Krabeva from Biocon, Ivzumab from RPG Life Sciences Ltd, and Advamab from Alkem Laboratories Ltd). Physiochemical characterization of drug products was performed with respect to their primary structure (intact mass, reduced mass, peptide mapping by LC-MS), higher order structure (secondary structure by FTIR, Far-UV-CD, and tertiary structure by Near-UV-CD, intrinsic fluorescence spectroscopy), impurity profile (SE-HPLC, SEC-MALS, extrinsic fluorescence: size heterogenicity, degradation, stability; DLS: hydrodynamic radius; WCX-HPLC: charge variants analysis) and post-translational modifications by measuring reduced glycans through fluorescence dye analysis. Functional characterization was performed by SPR and cell proliferation assay. Further, chemometrics based quantitative evaluation of biosimilarity has been performed by combining the data obtained from analytical characterization platform. The analysis of the analytical, functional and chemometric results revealed significant levels of similarity, with biosimilar4 being the sole exception. Despite being within product specifications, Biosimilar4 displayed significant deviations with respect to critical quality attributes, including a lower proportion of monomer content, a larger percentage of basic charge variant species, and a lower proportion of aglycosylated glycoform.


Assuntos
Medicamentos Biossimilares , Bevacizumab , Medicamentos Biossimilares/análise , Processamento de Proteína Pós-Traducional , Inibidores da Angiogênese , Mapeamento de Peptídeos/métodos
10.
J Am Soc Mass Spectrom ; 34(9): 1837-1846, 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37478497

RESUMO

LC-MS analysis of therapeutic antibodies and other biotherapeutics from in-life studies (e.g., serum/plasma) has evolved from simple peptide digestion to peptide mapping and intact mass monitoring. From more advanced analytical approaches, a deeper understanding as to the fate of the biotherapeutic in vivo is gained. Here, we examine the next generation of approaches to facilitate the most comprehensive understanding of large molecule drug fate in circulation. Three case studies are presented: (1) use of relative and absolute calibration curves for biotherapeutic quantitation from the same sample set; (2) top-down mass spectrometry applied to bioanalytical assays; (3) biotherapeutic protein complexes from serum analyzed by native protein MS. We anticipate that these approaches will be further adapted and applied by other research groups.


Assuntos
Proteínas , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Proteínas/análise , Peptídeos , Mapeamento de Peptídeos/métodos
11.
Sci Rep ; 13(1): 9038, 2023 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-37270636

RESUMO

Oligonucleotide mapping via liquid chromatography with UV detection coupled to tandem mass spectrometry (LC-UV-MS/MS) was recently developed to support development of Comirnaty, the world's first commercial mRNA vaccine which immunizes against the SARS-CoV-2 virus. Analogous to peptide mapping of therapeutic protein modalities, oligonucleotide mapping described here provides direct primary structure characterization of mRNA, through enzymatic digestion, accurate mass determinations, and optimized collisionally-induced fragmentation. Sample preparation for oligonucleotide mapping is a rapid, one-pot, one-enzyme digestion. The digest is analyzed via LC-MS/MS with an extended gradient and resulting data analysis employs semi-automated software. In a single method, oligonucleotide mapping readouts include a highly reproducible and completely annotated UV chromatogram with 100% maximum sequence coverage, and a microheterogeneity assessment of 5' terminus capping and 3' terminus poly(A)-tail length. Oligonucleotide mapping was pivotal to ensure the quality, safety, and efficacy of mRNA vaccines by providing: confirmation of construct identity and primary structure and assessment of product comparability following manufacturing process changes. More broadly, this technique may be used to directly interrogate the primary structure of RNA molecules in general.


Assuntos
COVID-19 , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , SARS-CoV-2/genética , Vacinas contra COVID-19 , Oligonucleotídeos/genética , COVID-19/prevenção & controle , Vacinas de mRNA , Mapeamento de Peptídeos/métodos , RNA Mensageiro/genética
12.
Anal Biochem ; 674: 115211, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37302778

RESUMO

LC-MS based multi-attribute methods (MAM) have drawn substantial attention due to their capability of simultaneously monitoring a large number of quality attributes of a biopharmaceutical product. For successful implementation of MAM, it is usually considered a requirement that the method is capable of detecting any new or missing peaks in the sample when compared to a control. Comparing a sample to a control for rare differences is also commonly practiced in many fields for investigational purpose. Because MS signal variability differs greatly between signals of different intensities, this type of comparison is often challenging, especially when the comparison is made without enough replicates. In this report we describe a statistical method for detecting rare differences between two very similar samples without replicate analyses. The method assumes that an overwhelming majority of components have equivalent abundance between the two samples, and signals with similar intensities have similar relative variability. By analyzing several monoclonal antibody peptide mapping datasets, we demonstrated that the method is suitable for new-peak detection for MAM as well as for other applications when rare differences between two samples need to be detected. The method greatly reduced false positive rate without a significant increase of false negative rate.


Assuntos
Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Mapeamento de Peptídeos/métodos
13.
J Pharm Biomed Anal ; 234: 115527, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37364451

RESUMO

Establishing analytical and functional comparability serves as the foundation of biosimilar development. A critical part of this exercise is sequence similarity search and categorization of post-translational modifications (PTMs), often by peptide mapping using liquid chromatography-mass spectrometry (LC-MS). When performing bottom-up proteomic sample preparation, efficient digestion of the protein and extraction of peptides for subsequent mass spectrometric analysis can be a challenge. Conventional sample preparation strategies face the risk of allowing interference of chemicals which are essential for extraction but are likely to interfere with digestion, resulting in complex chromatographic profiles due to semi-cleavages, insufficient peptide cleavages, and other unwanted reactions. Further, peptide cleanup through commonly used immobilized C-18 pipette tips can cause significant peptide loss as well as variability in individual peptide yields, thereby causing artifacts of various product-related modifications. In this study, we proposed a simple enzymatic digestion technique by incorporating different molecular weight filters and protein precipitation, with the objective to minimize interference of denaturing, reducing, and alkylating agents throughout overnight digestion. As a result, the need for peptide cleanup is significantly reduced and results in higher peptide yield. The proposed FAPP approach outperformed the conventional method across multiple metrics including, 30% more peptides, 8.19% more fully digested peptides, 14% higher sequence coverage rate, and 11.82% more site-specific alterations. Quantitative and qualitative repeatability of the proposed approach have been demonstrated. It can be concluded that the filter-assisted protein precipitation (FAPP) protocol proposed in this study offers an effective substitute for the traditional approach.


Assuntos
Medicamentos Biossimilares , Cromatografia Líquida/métodos , Mapeamento de Peptídeos/métodos , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos , Tripsina/química , Peptídeos/química
14.
Artigo em Inglês | MEDLINE | ID: mdl-37235786

RESUMO

Enzymes are mainly extracted from the culture broth of microorganisms. Various commercially available enzyme preparations (EPs) are derived from different microorganisms, and the source of the EP should be the same as that mentioned in the manufacture's information. The development of analytical methods that can determine the origin of the final products is important for ensuring that the EPs are nontoxic, especially when used as food additives. In this study, various EPs were subjected to SDS-PAGE, and the main protein bands were excised. After in-gel digestion, the generated peptides were analysed using MALDI-TOF MS, and protein identification was performed by searching the set of peptide masses against protein databases. In total, 36 EPs including amylase, ß-galactosidase, cellulase, hemicellulase and protease were analysed, and the information about the enzyme sources was obtained for 30 EPs. Among these, the biological sources determined for 25 EPs were consistent with the manufacturer's information; for the remaining five, enzymes produced by closely-related species were shown as matching proteins due to high sequence similarity. Six enzymes derived from four microorganisms could not be identified because their protein sequences were not registered in the database. As these databases are expanded, this approach of using SDS-PAGE and peptide mass fingerprinting (PMF) can determine the biological origin of enzymes rapidly and contribute to ensuring the safety of EPs.


Assuntos
Peptídeos , Proteínas , Peptídeos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Mapeamento de Peptídeos/métodos , Eletroforese em Gel de Poliacrilamida
15.
Molecules ; 28(6)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36985827

RESUMO

In the quest to market increasingly safer and more potent biotherapeutic proteins, the concept of the multi-attribute method (MAM) has emerged from biopharmaceutical companies to boost the quality-by-design process development. MAM strategies rely on state-of-the-art analytical workflows based on liquid chromatography coupled to mass spectrometry (LC-MS) to identify and quantify a selected series of critical quality attributes (CQA) in a single assay. Here, we aimed at evaluating the repeatability and robustness of a benchtop LC-MS platform along with bioinformatics data treatment pipelines for peptide mapping-based MAM studies using standardized LC-MS methods, with the objective to benchmark MAM methods across laboratories, taking nivolumab as a case study. Our results evidence strong interlaboratory consistency across LC-MS platforms for all CQAs (i.e., deamidation, oxidation, lysine clipping and glycosylation). In addition, our work uniquely highlights the crucial role of bioinformatics postprocessing in MAM studies, especially for low-abundant species quantification. Altogether, we believe that MAM has fostered the development of routine, robust, easy-to-use LC-MS platforms for high-throughput determination of major CQAs in a regulated environment.


Assuntos
Anticorpos Monoclonais , Anticorpos Monoclonais/química , Espectrometria de Massas/métodos , Cromatografia Líquida/métodos , Glicosilação , Mapeamento de Peptídeos/métodos
16.
J Am Soc Mass Spectrom ; 34(3): 401-408, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36705517

RESUMO

Recombinant therapeutic proteins have become the major class of drugs to treat various human diseases in recent years. Low levels of protein sequence variants (SVs) have been reported to be present in recombinant therapeutic proteins. The consequences of potential unwanted immune response from SVs of recombinant therapeutic proteins have increasingly drawn attention from regulatory authorities and the biopharmaceutical industry. It is highly desirable to detect low-level SVs during clone selection and early process development as part of the control strategy. Peptide mapping with LC-MS/MS analysis has been applied as a powerful tool to characterize post-translation modifications of therapeutic proteins. Despite the recent advancements in mass spectrometry hardware and software, it is still quite challenging and time-consuming to detect and identify low-level SVs. In this study, we present an optimized approach using new peak detection to detect and identify low level SVs with high confidence and high speed. The new approach makes sequence variants analysis by LC-MS/MS broadly applicable and practical in bioprocess development of therapeutic proteins.


Assuntos
Processamento de Proteína Pós-Traducional , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Mapeamento de Peptídeos/métodos , Sequência de Aminoácidos , Proteínas Recombinantes/genética , Proteínas Recombinantes/química
17.
Anal Chem ; 94(49): 17195-17204, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36346901

RESUMO

Peptide mapping by liquid chromatography mass spectrometry (LC-MS) and the related multi-attribute method (MAM) are well-established analytical tools for verification of the primary structure and mapping/quantitation of co- and post-translational modifications (PTMs) or product quality attributes in biopharmaceutical development. Proteolytic digestion is a key step in peptide mapping workflows, which traditionally is labor-intensive, involving multiple manual steps. Recently, simple high-temperature workflows with automatic digestion were introduced, which facilitate robustness and reproducibility across laboratories. Here, a modified workflow with an automatic digestion step is presented, which includes a two-step digestion at high and low temperatures, as opposed to the original one-step digestion at a high temperature. The new automatic digestion workflow significantly reduces the number of missed cleavages, obtaining a more complete digestion profile. In addition, we describe how chromatographic peak tailing and carry-over is dramatically reduced for hydrophobic peptides by switching from the traditional C18 reversed-phase (RP) column chemistry used for peptide mapping to a less retentive C4 column chemistry. No negative impact is observed on MS/MS-derived sequence coverage when switching to a C4 column chemistry. Overall, the new peptide mapping workflow significantly reduces the number of missed cleavages, yielding more robust and simple data interpretation, while providing dramatically reduced tailing and carry-over of hydrophobic peptides.


Assuntos
Peptídeos , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Cromatografia Líquida/métodos , Mapeamento de Peptídeos/métodos , Peptídeos/química , Fluxo de Trabalho
18.
J Am Soc Mass Spectrom ; 33(9): 1659-1677, 2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-36018776

RESUMO

The multi-attribute method (MAM) was conceived as a single assay to potentially replace multiple single-attribute assays that have long been used in process development and quality control (QC) for protein therapeutics. MAM is rooted in traditional peptide mapping methods; it leverages mass spectrometry (MS) detection for confident identification and quantitation of many types of protein attributes that may be targeted for monitoring. While MAM has been widely explored across the industry, it has yet to gain a strong foothold within QC laboratories as a replacement method for established orthogonal platforms. Members of the MAM consortium recently undertook an interlaboratory study to evaluate the industry-wide status of MAM. Here we present the results of this study as they pertain to the targeted attribute analytics component of MAM, including investigation into the sources of variability between laboratories and comparison of MAM data to orthogonal methods. These results are made available with an eye toward aiding the community in further optimizing the method to enable its more frequent use in the QC environment.


Assuntos
Benchmarking , Proteínas , Espectrometria de Massas/métodos , Mapeamento de Peptídeos/métodos , Controle de Qualidade
19.
Anal Chem ; 94(24): 8580-8587, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35678765

RESUMO

Additive manufacturing (3D printing) has greatly revolutionized the way researchers approach certain technical challenges. Despite its outstanding print quality and resolution, stereolithography (SLA) printing is cost-effective and relatively accessible. However, applications involving mass spectrometry (MS) are few due to residual oligomers and additives leaching from SLA-printed devices that interfere with MS analyses. We identified the crosslinking agent urethane dimethacrylate as the main contaminant derived from SLA prints. A stringent washing and post-curing protocol mitigated sample contamination and rendered SLA prints suitable for MS hyphenation. Thereafter, SLA printing was used to produce 360 µm I.D. microcolumn chips with excellent structural properties. By packing the column with polystyrene microspheres and covalently immobilizing pepsin, an exceptionally effective microscale immobilized enzyme reactor (µIMER) was created. Implemented in an online liquid chromatography-MS/MS setup, the protease microcolumn enabled reproducible protein digestion and peptide mapping with 100% sequence coverage obtained for three different recombinant proteins. Additionally, when assessing the µIMER digestion efficiency for complex proteome samples, it delivered a 144-fold faster and significantly more efficient protein digestion compared to 24 h for bulk digestion. The 3D-printed µIMER withstands remarkably high pressures above 130 bar and retains its activity for several weeks. This versatile platform will enable researchers to produce tailored polymer-based enzyme reactors for various applications in analytical chemistry and beyond.


Assuntos
Enzimas Imobilizadas , Espectrometria de Massas em Tandem , Cromatografia Líquida , Enzimas Imobilizadas/química , Mapeamento de Peptídeos/métodos , Impressão Tridimensional
20.
J Sep Sci ; 45(15): 2887-2900, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35670633

RESUMO

Peptide mapping by liquid chromatography-mass spectrometry is the gold standard to characterize post-translational modifications (PTMs) and disulfide bonds. The structural integrity, heterogeneity, and quality of biotherapeutic proteins are evaluated via reduced and non-reduced peptide mapping methods. However, non-enzymatic artifacts are often induced during sample preparation when alkaline pH conditions are used. To minimize these artifacts, methods using various acidic pH conditions have been developed by multiple researchers. However, these may lead to missed and non-specific cleavages during the analysis. In this study, an improved reduced and non-reduced peptide mapping method has been proposed to characterize endogenous chemical modifications and native disulfide bonds of monoclonal antibody-based products. Solubilization has been carried out at acidic pH conditions under high temperature, followed by the addition of tris (2-carboxyethyl) phosphine as a reducing agent and a low alkylating agent. It was observed that the non-enzymatic PTMs and non-native disulfide scrambled peptides significantly reduced under trypsin plus endoproteinase Lys-C digestion conditions at acidic pH as compared to the traditional methods. The results demonstrate that the proposed reduced and non-reduced peptide mapping method using trypsin plus Lys-C could identify and quantify various chemical and disulfide heterogeneities with minimal artifacts.


Assuntos
Anticorpos Monoclonais , Dissulfetos , Anticorpos Monoclonais/química , Dissulfetos/química , Mapeamento de Peptídeos/métodos , Rituximab , Tripsina/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...