Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.190
Filtrar
1.
Early Hum Dev ; 194: 106047, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38851106

RESUMO

BACKGROUND: Neonatal chest-Xray (CXR)s are commonly performed as a first line investigation for the evaluation of respiratory complications. Although lung area derived from CXRs correlates well with functional assessments of the neonatal lung, it is not currently utilised in clinical practice, partly due to the lack of reference ranges for CXR-derived lung area in healthy neonates. Advanced MR techniques now enable direct evaluation of both fetal pulmonary volume and area. This study therefore aims to generate reference ranges for pulmonary volume and area in uncomplicated pregnancies, evaluate the correlation between prenatal pulmonary volume and area, as well as to assess the agreement between antenatal MRI-derived and neonatal CXR-derived pulmonary area in a cohort of fetuses that delivered shortly after the antenatal MRI investigation. METHODS: Fetal MRI datasets were retrospectively analysed from uncomplicated term pregnancies and a preterm cohort that delivered within 72 h of the fetal MRI. All examinations included T2 weighted single-shot turbo spin echo images in multiple planes. In-house pipelines were applied to correct for fetal motion using deformable slice-to-volume reconstruction. An MRI-derived lung area was manually segmented from the average intensity projection (AIP) images generated. Postnatal lung area in the preterm cohort was measured from neonatal CXRs within 24 h of delivery. Pearson correlation coefficient was used to correlate MRI-derived lung volume and area. A two-way absolute agreement was performed between the MRI-derived AIP lung area and CXR-derived lung area. RESULTS: Datasets from 180 controls and 10 preterm fetuses were suitable for analysis. Mean gestational age at MRI was 28.6 ± 4.2 weeks for controls and 28.7 ± 2.7 weeks for preterm neonates. MRI-derived lung area correlated strongly with lung volumes (p < 0.001). MRI-derived lung area had good agreement with the neonatal CXR-derived lung area in the preterm cohort [both lungs = 0.982]. CONCLUSION: MRI-derived pulmonary area correlates well with absolute pulmonary volume and there is good correlation between MRI-derived pulmonary area and postnatal CXR-derived lung area when delivery occurs within a few days of the MRI examination. This may indicate that fetal MRI derived lung area may prove to be useful reference ranges for pulmonary areas derived from CXRs obtained in the perinatal period.


Assuntos
Pulmão , Imageamento por Ressonância Magnética , Humanos , Pulmão/diagnóstico por imagem , Pulmão/embriologia , Imageamento por Ressonância Magnética/métodos , Feminino , Gravidez , Recém-Nascido , Medidas de Volume Pulmonar/métodos , Estudos Retrospectivos
2.
Sci Rep ; 14(1): 10594, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719953

RESUMO

Colorectal liver metastases (CRLM) are the predominant factor limiting survival in patients with colorectal cancer and liver resection with complete tumor removal is the best treatment option for these patients. This study examines the predictive ability of three-dimensional lung volumetry (3DLV) based on preoperative computerized tomography (CT), to predict postoperative pulmonary complications in patients undergoing major liver resection for CRLM. Patients undergoing major curative liver resection for CRLM between 2010 and 2021 with a preoperative CT scan of the thorax within 6 weeks of surgery, were included. Total lung volume (TLV) was calculated using volumetry software 3D-Slicer version 4.11.20210226 including Chest Imaging Platform extension ( http://www.slicer.org ). The area under the curve (AUC) of a receiver-operating characteristic analysis was used to define a cut-off value of TLV, for predicting the occurrence of postoperative respiratory complications. Differences between patients with TLV below and above the cut-off were examined with Chi-square or Fisher's exact test and Mann-Whitney U tests and logistic regression was used to determine independent risk factors for the development of respiratory complications. A total of 123 patients were included, of which 35 (29%) developed respiratory complications. A predictive ability of TLV regarding respiratory complications was shown (AUC 0.62, p = 0.036) and a cut-off value of 4500 cm3 was defined. Patients with TLV < 4500 cm3 were shown to suffer from significantly higher rates of respiratory complications (44% vs. 21%, p = 0.007) compared to the rest. Logistic regression analysis identified TLV < 4500 cm3 as an independent predictor for the occurrence of respiratory complications (odds ratio 3.777, 95% confidence intervals 1.488-9.588, p = 0.005). Preoperative 3DLV is a viable technique for prediction of postoperative pulmonary complications in patients undergoing major liver resection for CRLM. More studies in larger cohorts are necessary to further evaluate this technique.


Assuntos
Neoplasias Colorretais , Hepatectomia , Neoplasias Hepáticas , Complicações Pós-Operatórias , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Pessoa de Meia-Idade , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/secundário , Idoso , Hepatectomia/efeitos adversos , Hepatectomia/métodos , Complicações Pós-Operatórias/etiologia , Pulmão/patologia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Estudos Retrospectivos , Imageamento Tridimensional , Medidas de Volume Pulmonar , Fatores de Risco , Período Pré-Operatório
4.
BMJ Open Respir Res ; 11(1)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38663888

RESUMO

OBJECTIVE: This study aimed to investigate the utility of CT quantification of lung volume for predicting critical outcomes in COVID-19 patients. METHODS: This retrospective cohort study included 1200 hospitalised patients with COVID-19 from 4 hospitals. Lung fields were extracted using artificial intelligence-based segmentation, and the percentage of the predicted (%pred) total lung volume (TLC (%pred)) was calculated. The incidence of critical outcomes and posthospitalisation complications was compared between patients with low and high CT lung volumes classified based on the median percentage of predicted TLCct (n=600 for each). Prognostic factors for residual lung volume loss were investigated in 208 patients with COVID-19 via a follow-up CT after 3 months. RESULTS: The incidence of critical outcomes was higher in the low TLCct (%pred) group than in the high TLCct (%pred) group (14.2% vs 3.3%, p<0.0001). Multivariable analysis of previously reported factors (age, sex, body mass index and comorbidities) demonstrated that CT-derived lung volume was significantly associated with critical outcomes. The low TLCct (%pred) group exhibited a higher incidence of bacterial infection, heart failure, thromboembolism, liver dysfunction and renal dysfunction than the high TLCct (%pred) group. TLCct (%pred) at 3 months was similarly divided into two groups at the median (71.8%). Among patients with follow-up CT scans, lung volumes showed a recovery trend from the time of admission to 3 months but remained lower in critical cases at 3 months. CONCLUSION: Lower CT lung volume was associated with critical outcomes, posthospitalisation complications and slower improvement of clinical conditions in COVID-19 patients.


Assuntos
COVID-19 , Medidas de Volume Pulmonar , Pulmão , SARS-CoV-2 , Tomografia Computadorizada por Raios X , Humanos , COVID-19/diagnóstico por imagem , COVID-19/epidemiologia , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Japão/epidemiologia , Medidas de Volume Pulmonar/métodos , Pulmão/diagnóstico por imagem , Prognóstico , Estudos de Coortes , Idoso de 80 Anos ou mais
5.
Crit Care ; 28(1): 142, 2024 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-38689313

RESUMO

RATIONALE: End-expiratory lung volume (EELV) is reduced in mechanically ventilated patients, especially in pathologic conditions. The resulting heterogeneous distribution of ventilation increases the risk for ventilation induced lung injury. Clinical measurement of EELV however, remains difficult. OBJECTIVE: Validation of a novel continuous capnodynamic method based on expired carbon dioxide (CO2) kinetics for measuring EELV in mechanically ventilated critically-ill patients. METHODS: Prospective study of mechanically ventilated patients scheduled for a diagnostic computed tomography exploration. Comparisons were made between absolute and corrected EELVCO2 values, the latter accounting for the amount of CO2 dissolved in lung tissue, with the reference EELV measured by computed tomography (EELVCT). Uncorrected and corrected EELVCO2 was compared with total CT volume (density compartments between - 1000 and 0 Hounsfield units (HU) and functional CT volume, including density compartments of - 1000 to - 200HU eliminating regions of increased shunt. We used comparative statistics including correlations and measurement of accuracy and precision by the Bland Altman method. MEASUREMENTS AND MAIN RESULTS: Of the 46 patients included in the final analysis, 25 had a diagnosis of ARDS (24 of which COVID-19). Both EELVCT and EELVCO2 were significantly reduced (39 and 40% respectively) when compared with theoretical values of functional residual capacity (p < 0.0001). Uncorrected EELVCO2 tended to overestimate EELVCT with a correlation r2 0.58; Bias - 285 and limits of agreement (LoA) (+ 513 to - 1083; 95% CI) ml. Agreement improved for the corrected EELVCO2 to a Bias of - 23 and LoA of (+ 763 to - 716; 95% CI) ml. The best agreement of the method was obtained by comparison of corrected EELVCO2 with functional EELVCT with a r2 of 0.59; Bias - 2.75 (+ 755 to - 761; 95% CI) ml. We did not observe major differences in the performance of the method between ARDS (most of them COVID related) and non-ARDS patients. CONCLUSION: In this first validation in critically ill patients, the capnodynamic method provided good estimates of both total and functional EELV. Bias improved after correcting EELVCO2 for extra-alveolar CO2 content when compared with CT estimated volume. If confirmed in further validations EELVCO2 may become an attractive monitoring option for continuously monitor EELV in critically ill mechanically ventilated patients. TRIAL REGISTRATION: clinicaltrials.gov (NCT04045262).


Assuntos
Capnografia , Estado Terminal , Medidas de Volume Pulmonar , Humanos , Masculino , Feminino , Estado Terminal/terapia , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Medidas de Volume Pulmonar/métodos , Capnografia/métodos , Respiração Artificial/métodos , COVID-19 , Tomografia Computadorizada por Raios X/métodos , Adulto
6.
J Pediatr Orthop ; 44(6): 366-372, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38595095

RESUMO

OBJECTIVE: Severe spinal deformity results in restrictive pulmonary disease from thoracic distortions and lung-volume limitations. Though spirometry and body plethysmography are widely accepted tests for pulmonary function tests (PFTs), they are time-consuming and require patient compliance. This study investigates whether surface topographic [surface topography (ST)] measurements of body volume difference (BVD) and torso volume difference between maximum inhale and exhale correlate to values determined on PFTs. METHODS: This study included patients with idiopathic scoliosis and thoracic/thoracolumbar curves ≥40 degrees. Patients received ST scans, clinical examinations, and EOS biplanar radiographs on the same day. PFTs were performed within 3 months of ST/radiographic analysis. Univariate linear regression analysis was used to examine relationships between BVD, PFT values, and mean curves. RESULTS: Sixteen patients (14.6 ± 2.2 y, 69% females) with idiopathic scoliosis and mean thoracic/thoracolumbar curves of 62 degrees ± 15˚ degrees (45 degrees to 93 degrees) were assessed. BVD displayed statistically high-positive positive correlations with forced vital capacity ( R = 0.863, P < 0.0001), forced expiratory volume in 1 second ( R = 0.870, P < 0.001), vital capacity ( R = 0.802, P < 0.0001), and TLC ( R = 0.831, P < 0.0001. Torso volume difference showed similarly high positive correlations to forced vital capacity, forced expiratory volume in 1 second, vital capacity, and TLC, but not residual volume. No correlations emerged between the mean thoracic/thoracolumbar curve and BVD or PFT values. CONCLUSION: This study strongly endorses further investigation into ST scanning as an alternative to traditional PFTs for assessing pulmonary volumes. The noncontact and noninvasive nature of ST scanning presents a valuable alternative method for analyzing thoracic volume, particularly beneficial for patients unable to cooperate with standard PFTs. LEVEL OF EVIDENCE: Level II-prognostic.


Assuntos
Medidas de Volume Pulmonar , Testes de Função Respiratória , Escoliose , Humanos , Escoliose/fisiopatologia , Escoliose/diagnóstico por imagem , Feminino , Masculino , Adolescente , Criança , Medidas de Volume Pulmonar/métodos , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem , Espirometria/métodos
7.
Clin Physiol Funct Imaging ; 44(4): 340-348, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38576112

RESUMO

BACKGROUND: Computed tomography (CT) offers pulmonary volumetric quantification but is not commonly used in healthy individuals due to radiation concerns. Chronic airflow limitation (CAL) is one of the diagnostic criteria for chronic obstructive pulmonary disease (COPD), where early diagnosis is important. Our aim was to present reference values for chest CT volumetric and radiodensity measurements and explore their potential in detecting early signs of CAL. METHODS: From the population-based Swedish CArdioPulmonarybioImage Study (SCAPIS), 294 participants aged 50-64, were categorized into non-CAL (n = 258) and CAL (n = 36) groups based on spirometry. From inspiratory and expiratory CT images we compared lung volumes, mean lung density (MLD), percentage of low attenuation volume (LAV%) and LAV cluster volume between groups, and against reference values from static pulmonary function test (PFT). RESULTS: The CAL group exhibited larger lung volumes, higher LAV%, increased LAV cluster volume and lower MLD compared to the non-CAL group. Lung volumes significantly deviated from PFT values. Expiratory measurements yielded more reliable results for identifying CAL compared to inspiratory. Using a cut-off value of 0.6 for expiratory LAV%, we achieved sensitivity, specificity and positive/negative predictive values of 72%, 85% and 40%/96%, respectively. CONCLUSION: We present volumetric reference values from inspiratory and expiratory chest CT images for a middle-aged healthy cohort. These results are not directly comparable to those from PFTs. Measures of MLD and LAV can be valuable in the evaluation of suspected CAL. Further validation and refinement are necessary to demonstrate its potential as a decision support tool for early detection of COPD.


Assuntos
Medidas de Volume Pulmonar , Pulmão , Valor Preditivo dos Testes , Doença Pulmonar Obstrutiva Crônica , Espirometria , Humanos , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Masculino , Feminino , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Medidas de Volume Pulmonar/métodos , Reprodutibilidade dos Testes , Suécia , Tomografia Computadorizada por Raios X/métodos , Volume Expiratório Forçado , Diagnóstico Precoce
9.
Respir Res ; 25(1): 155, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570835

RESUMO

BACKGROUND: Reference values for lung volumes are necessary to identify and diagnose restrictive lung diseases and hyperinflation, but the values have to be validated in the relevant population. Our aim was to investigate the Global Lung Function Initiative (GLI) reference equations in a representative healthy Austrian population and create population-derived reference equations if poor fit was observed. METHODS: We analysed spirometry and body plethysmography data from 5371 respiratory healthy subjects (6-80 years) from the Austrian LEAD Study. Fit with the GLI equations was examined using z-scores and distributions within the limits of normality. LEAD reference equations were then created using the LMS method and the generalized additive model of location shape and scale package according to GLI models. RESULTS: Good fit, defined as mean z-scores between + 0.5 and -0.5,was not observed for the GLI static lung volume equations, with mean z-scores > 0.5 for residual volume (RV), RV/TLC (total lung capacity) and TLC in both sexes, and for expiratory reserve volume (ERV) and inspiratory capacity in females. Distribution within the limits of normality were shifted to the upper limit except for ERV. Population-derived reference equations from the LEAD cohort showed superior fit for lung volumes and provided reproducible results. CONCLUSION: GLI lung volume reference equations demonstrated a poor fit for our cohort, especially in females. Therefore a new set of Austrian reference equations for static lung volumes was developed, that can be applied to both children and adults (6-80 years of age).


Assuntos
Pulmão , Masculino , Adulto , Criança , Feminino , Humanos , Áustria/epidemiologia , Valores de Referência , Medidas de Volume Pulmonar/métodos , Capacidade Pulmonar Total , Espirometria/métodos , Volume Expiratório Forçado , Capacidade Vital
10.
Medicina (B Aires) ; 84(2): 359-363, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38683525

RESUMO

The apnea test, employed for brain death assessment, aims to demonstrate the absence of respiratory drive due to hypercapnia. The tracheal oxygen insufflation apnea test mode (I-AT) involves disconnecting the patient from invasive mechanical ventilation (iMV) for approximately 8 minutes while maintaining oxygenation. This test supports the diagnosis of brain death based on a specified increase in PaCO2. Common complications include hypoxemia and hemodynamic instability, and lung collapse-induced reduction in end-expiratory lung volume (EELV). In our case series utilizing electrical impedance tomography (EIT), we observed that continuous positive airway pressure during the apnea test (CPAP-AT) effectively mitigated lung collapse. This resulted in improved pulmonary strain compared to the disconnection of iMV. These findings suggest the potential benefits of routine CPAP-AT, particularly for potential lung donors, emphasizing the relevance of our study in providing quantitative insights into EELV loss and its association with pulmonary strain and potential lung injury.


La prueba de apnea es una técnica diagnóstica ampliamente utilizada para la evaluación de la muerte cerebral, con el objetivo de demostrar la ausencia de impulso respiratorio debido a la hipercapnia. La variante de la prueba de apnea con insuflación de oxígeno traqueal (I-AT) implica desconectar al paciente de la ventilación mecánica invasiva (iVM) durante aproximadamente 8 minutos, manteniendo la oxigenación mediante un catéter de insuflación. Esta prueba respalda el diagnóstico de muerte cerebral cuando se determina un aumento de la PaCO 2 superior a 20 mmHg en comparación con el valor inicial o un nivel de PaCO 2 superior a 60 mmHg al final de la prueba. En nuestra serie de casos, la implementación de la tomografía de impedancia eléctrica (EIT) reveló que la prueba de apnea con presión positiva continua (CPAPAT) mitiga eficazmente el colapso pulmonar. Este enfoque resulta en una mejora en la tensión pulmonar en comparación con la desconexión de iMV, demostrando su relevancia en el contexto de potenciales donantes de pulmones.


Assuntos
Impedância Elétrica , Medidas de Volume Pulmonar , Humanos , Masculino , Feminino , Medidas de Volume Pulmonar/métodos , Pessoa de Meia-Idade , Apneia/fisiopatologia , Morte Encefálica/fisiopatologia , Morte Encefálica/diagnóstico , Morte Encefálica/diagnóstico por imagem , Adulto , Tomografia/métodos , Pressão Positiva Contínua nas Vias Aéreas , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Idoso
11.
Sci Rep ; 14(1): 8119, 2024 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582758

RESUMO

Breathing difficulties and exertional dyspnea are frequently reported in hypermobile Ehlers-Danlos syndrome (hEDS); however, they are not clearly explained. An impaired proprioception or the addition of a cognitive task could influence ventilatory control. How can the perception of lung volume be measured? Is lung volume perception impaired in hEDS patients? Is the breathing control impaired during a cognitive task in hEDS patients? A device was developed to assess the accuracy of lung volume perception in patients with hEDS and matched control subjects. In the second step, ventilation was recorded in both groups with and without a cognitive task. Two groups of 19 subjects were included. The accuracy of lung volume perception was significantly (P < 0.01) lower at 30% of inspired vital capacity in patients with hEDS in comparison to the control group, and they showed erratic ventilation (based on spatial and temporal criteria) when performing a cognitive task. These data support the influence of the proprioceptive deficit on ventilatory control in hEDS patients. These elements may help to understand the respiratory manifestations found in hEDS. Future research should focus on this relationship between lung volume perception and ventilation, and could contribute to our understanding of other pathologies or exercise physiology.Trial registration number: ClinicalTrials.gov, NCT05000151.


Assuntos
Síndrome de Ehlers-Danlos , Humanos , Síndrome de Ehlers-Danlos/patologia , Pulmão/patologia , Dispneia , Medidas de Volume Pulmonar , Percepção
13.
Kyobu Geka ; 77(2): 83-86, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459855

RESUMO

A 59-year-old male patient was referred to our hospital for further examinations and treatment due to an abnormal shadow detected in his left lower lung lobe on computed tomography. The patient was diagnosed with intralobar pulmonary sequestration and scheduled for an operation. During the surgery, after resection of the aberrant artery, indocyanine green was intravenously injected, and the border between normal lung and sequestrated lung was clearly identified by an infrared thoracoscope. Subsequently, wedge resection was performed, and the patient was discharged on postoperative day 5. Spirometry performed 6 months after the surgery indicated that the patient's lung function was well-preserved compared to the preoperative status.


Assuntos
Sequestro Broncopulmonar , Procedimentos Cirúrgicos Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Sequestro Broncopulmonar/diagnóstico por imagem , Sequestro Broncopulmonar/cirurgia , Toracoscópios , Pulmão , Medidas de Volume Pulmonar
14.
Respir Care ; 69(3): 366-375, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38416659

RESUMO

BACKGROUND: Lung hyperinflation is a typical clinical feature of patients with COPD. Given the association between breathing at elevated lung volumes and the manifestation of severe debilitating symptoms, therapeutic interventions such as positive expiratory pressure (PEP) therapy and its variations (temporary, oscillatory) have been devised to mitigate lung hyperinflation. However, the efficacy of these interventions remains to be conclusively demonstrated. METHODS: A systematic review with meta-analysis of randomized trials was conducted following the PRISMA guidelines. Seven databases were screened with no date or language restriction. Two authors independently applied eligibility criteria and assessed the risk of bias of included studies using the Cochrane risk-of-bias tool. Outcomes were lung hyperinflation measures detected through changes in inspiratory capacity (IC), functional residual capacity (FRC), total lung capacity (TLC), and residual volume (RV), as well as FEV1, FVC, dyspnea, and physical capacity. Pooled standardized mean differences (SMDs) or mean differences (MDs) and 95% CI were calculated using a random-effects model. RESULTS: Seven trials, all with a high risk of bias, were included. Compared to control group, RV significantly decreased (4 studies, n = 231; SMD -0.42 [95% CI -0.77 to -0.08], P = .02), dyspnea improved (n = 321, SMD -1.17 [95% CI -1.68 to -0.66], P < .001), and physical capacity increased (5 studies, n = 311; MD 30.1 [95% CI 19.2-41.0] m, P < .001) with PEP therapy. There was no significant difference between PEP therapy and the control group in TLC, FVC, or FEV1. Only one study reported changes in inspiratory capacity as well as FRC. CONCLUSIONS: In patients with COPD, the effect of PEP therapy on lung hyperinflation is unclear owing to the non-consistent change in lung hyperinflation outcomes, insufficient data, and lack of high-quality trials. Dyspnea and physical capacity might improve with PEP therapy.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Medidas de Volume Pulmonar , Capacidade Pulmonar Total , Volume Residual , Dispneia/etiologia , Dispneia/terapia , Dispneia/diagnóstico , Volume Expiratório Forçado
15.
Respirology ; 29(5): 387-395, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38320863

RESUMO

BACKGROUND AND OBJECTIVE: The identification of progression in patients with fibrosing non-idiopathic pulmonary fibrosis (IPF) interstitial lung diseases (ILDs) represents an ongoing clinical challenge. Lung function decline alone may have significant limitations in the detection of clinically significant progression. We hypothesized that longitudinal changes of 6-min walk distance (6MWD) from baseline, simultaneously considered with measures of lung function, may independently predict survival and identifying clinically significant progression of disease. METHODS: Forced vital capacity (FVC), diffusing lung capacity (DLCO) and 6MWD were considered both at baseline and at 1 year in a discovery cohort (n = 105) and in a validation cohort (n = 138) from different centres. The primary endpoint was lung transplant (LTx)-free survival. RESULTS: Average follow-up was 3 years in both cohorts. Combined incidence of deaths and LTx was 29% and 21%, respectively. No collinearity and no strong correlations were observed among FVC, DLCO and 6MWD longitudinal changes. While age, gender and BMI were not significant, 6MWD decline ≥24 m predicted LTx-free-survival significantly and independently from FVC and DLCO declines, with high sensitivity and specificity, in both the discovery and the validation cohorts. Although FVC and DLCO declines remained significant predictors of LTx-free survival, 6MWD decline was more accurate than the proposed ATS/ERS/JRS/ALAT functional criteria. Results were confirmed after stratifying patients by baseline FVC. CONCLUSION: Longitudinal declines of 6MWD are associated with poor survival in fibrosing ILDs across a wide range of baseline severity, with high accuracy. 6MWD longitudinal decline is largely independent from lung function decline and may be integrated into the routine assessment of progression.


Assuntos
Doenças Pulmonares Intersticiais , Transplante de Pulmão , Humanos , Pulmão/cirurgia , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/cirurgia , Doenças Pulmonares Intersticiais/etiologia , Capacidade Vital , Medidas de Volume Pulmonar , Transplante de Pulmão/efeitos adversos , Progressão da Doença
16.
Adv Physiol Educ ; 48(2): 279-283, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38299212

RESUMO

Here we demonstrate how data from the clinical pulmonary function lab can help students learn about the principle of airway-parenchymal interdependence. We examined the relationship between airway conductance (Gaw) and lung volume (thoracic gas volume, TGV) in 48 patients: 17 healthy; 20 with emphysema, expected to have reduced airway-parenchymal interdependence; and 11 with pulmonary fibrosis, expected to have increased airway-parenchymal interdependence. Our findings support these expectations, with the slope of Gaw vs. TGV being steeper among those with pulmonary fibrosis and flatter among those with emphysema, compared to the slope of the healthy group. This type of analytic approach, using real-world patient data readily available from any pulmonary function laboratory, can be used to explore other fundamental principles of respiratory physiology.NEW & NOTEWORTHY This report demonstrates how common data obtained from the clinical pulmonary function testing laboratory can be used to illustrate important principles of respiratory physiology. Here we show how the relationship between airway conductance and lung volume across different disease states reflects intrinsic differences in airway-parenchymal interdependence.


Assuntos
Enfisema , Fibrose Pulmonar , Humanos , Pulmão/fisiologia , Medidas de Volume Pulmonar , Fenômenos Fisiológicos Respiratórios
17.
Int J Sports Physiol Perform ; 19(5): 463-470, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38412852

RESUMO

PURPOSE: To investigate the effects of repeated-sprint training with voluntary hypoventilation at low (RSH-VHL) and high (RS-VHH) lung volume on repeated-sprint ability (RSA) in female athletes. METHODS: Over a 6-week period, 24 female soccer players completed 12 sessions of repeated 30-m running sprints with end-expiratory breath holding (RSH-VHL, n = 8), end-inspiratory breath holding (RS-VHH, n = 8), or unrestricted breathing (RS-URB, n = 8). Before and after training, a running RSA test consisting of performing 30-m all-out sprints until exhaustion was implemented. RESULTS: From before to after training, the number of sprints completed during the RSA test was increased in both RSH-VHL (19.3 [0.9] vs 22.6 [0.9]; P < .01) and RS-VHH (19.3 [1.5] vs 20.5 [1.7]; P < .01) but not in RS-URB (19.4 [1.3] vs 19.5 [1.7]; P = .67). The mean velocity and the percentage decrement score calculated over sprints 1 to 17 were, respectively, higher (82.2% [1.8%] vs 84.6% [2.1%] of maximal velocity) and lower (23.7% [3.1%] vs 19.4% [3.2%]) in RSH-VHL (P < .01), whereas they remained unchanged in RS-VHH and RS-URB. The mean arterial oxygen saturation recorded during training at the end of the sprints was lower in RSH-VHL (92.1% [0.4%]) than in RS-VHH (97.3% [0.1%]) and RS-URB (97.8% [0.1%]). CONCLUSIONS: This study shows that female athletes can benefit from the RSH-VHL intervention to improve RSA. The performance gains may have been limited by the short sprinting distance with end-expiratory breath holding, which provoked only moderate hypoxemia. The increase in the number of sprints in RS-VHH seems to show that factors other than hypoxia may have played a role in RSA improvement.


Assuntos
Desempenho Atlético , Suspensão da Respiração , Condicionamento Físico Humano , Corrida , Futebol , Humanos , Feminino , Futebol/fisiologia , Desempenho Atlético/fisiologia , Corrida/fisiologia , Condicionamento Físico Humano/métodos , Adulto Jovem , Hipoventilação , Consumo de Oxigênio , Medidas de Volume Pulmonar
18.
Chest ; 165(6): 1406-1414, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38295948

RESUMO

BACKGROUND: Reconnection to the ventilator for 1 h following a successful spontaneous breathing trial (SBT) may reduce reintubation rates compared with direct extubation. However, the physiologic mechanisms leading to this effect are unclear. RESEARCH QUESTION: Does reconnection to the ventilator for 1 h reverse alveolar derecruitment induced by SBT, and is alveolar derecruitment more pronounced with a T-piece than with pressure-support ventilation (PSV)? STUDY DESIGN AND METHODS: This is an ancillary study of a randomized clinical trial comparing SBT performed with a T-piece or with PSV. Alveolar recruitment was assessed by using measurement of end-expiratory lung volume (EELV). RESULTS: Of the 25 patients analyzed following successful SBT, 11 underwent SBT with a T-piece and 14 with PSV. At the end of the SBT, EELV decreased by -30% (95% CI, -37 to -23) compared with baseline prior to the SBT. This reduction was greater with a T-piece than with PSV: -43% (95% CI, -51 to -35) vs -20% (95% CI, -26 to -13); P < .001. Following reconnection to the ventilator for 1 h, EELV accounted for 96% (95% CI, 92 to 101) of baseline EELV and did not significantly differ from prior to the SBT (P = .104). Following 10 min of reconnection to the ventilator, EELV wasted at the end of the SBT was completely recovered using PSV (P = .574), whereas it remained lower than prior to the SBT using a T-piece (P = .010). INTERPRETATION: Significant alveolar derecruitment was observed at the end of an SBT and was markedly more pronounced with a T-piece than with PSV. Reconnection to the ventilator for 1 h allowed complete recovery of alveolar derecruitment. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT04227639; URL: www. CLINICALTRIALS: gov.


Assuntos
Desmame do Respirador , Humanos , Masculino , Feminino , Desmame do Respirador/métodos , Pessoa de Meia-Idade , Idoso , Fatores de Tempo , Extubação/métodos , Respiração com Pressão Positiva/métodos , Respiração com Pressão Positiva/instrumentação , Respiração Artificial/métodos , Respiração Artificial/instrumentação , Medidas de Volume Pulmonar
19.
Anesthesiology ; 140(4): 752-764, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38207290

RESUMO

BACKGROUND: Lower fractional inspired oxygen tension (Fio2) during general anesthesia can reduce lung atelectasis. The objectives are to evaluate the effect of two Fio2 (0.4 and 1) during low positive end-expiratory pressure (PEEP) ventilation over lung perfusion distribution, volume, and regional ventilation. These variables were evaluated at two PEEP levels and unilateral lung atelectasis. METHODS: In this exploratory study, 10 healthy female piglets (32.3 ± 3.4 kg) underwent mechanical ventilation in two atelectasis models: (1) bilateral gravitational atelectasis (n = 6), induced by changes in PEEP and Fio2 in three combinations: high PEEP with low Fio2 (Fio2 = 0.4), zero PEEP (PEEP0) with low Fio2 (Fio2 = 0.4), and PEEP0 with high Fio2 (Fio2 = 1); and (2) unilateral atelectasis (n = 6), induced by left bronchial occlusion, with the left lung aerated (Fio2 = 0.21) and low aerated (Fio2 = 1; n = 5 for this step). Measurements were conducted after 10 min in each step, encompassing assessment of respiratory mechanics, oxygenation, and hemodynamics; lung ventilation and perfusion by electrical impedance tomography; and lung aeration and perfusion by computed tomography. RESULTS: During bilateral gravitational atelectasis, PEEP reduction increased atelectasis in dorsal regions, decreased respiratory compliance, and distributed lung ventilation to ventral regions with a parallel shift of perfusion to the same areas. With PEEP0, there were no differences between low and high Fio2 in respiratory compliance (23.9 ± 6.5 ml/cm H2O vs. 21.9 ± 5.0; P = 0.441), regional ventilation, and regional perfusion, despite higher lung collapse (18.6 ± 7.6% vs. 32.7 ± 14.5%; P = 0.045) with high Fio2. During unilateral lung atelectasis, the deaerated lung had a lower shunt (19.3 ± 3.6% vs. 25.3 ± 5.5%; P = 0.045) and lower computed tomography perfusion to the left lung (8.8 ± 1.8% vs. 23.8 ± 7.1%; P = 0.007). CONCLUSIONS: PEEP0 with low Fio2, compared with high Fio2, did not produce significant changes in respiratory system compliance, regional lung ventilation, and perfusion despite significantly lower lung collapse. After left bronchial occlusion, the shrinkage of the parenchyma with Fio2 = 1 enhanced hypoxic pulmonary vasoconstriction, reducing intrapulmonary shunt and perfusion of the nonventilated areas.


Assuntos
Atelectasia Pulmonar , Respiração Artificial , Animais , Feminino , Suínos , Respiração Artificial/métodos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Atelectasia Pulmonar/diagnóstico por imagem , Atelectasia Pulmonar/terapia , Perfusão , Oxigênio
20.
J Clin Monit Comput ; 38(2): 539-551, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38238635

RESUMO

Tidal volume (TV) monitoring breath-by-breath is not available at bedside in non-intubated patients. However, TV monitoring may be useful to evaluate the work of breathing. A non-invasive device based on bioimpedance provides continuous and real-time volumetric tidal estimation during spontaneous breathing. We performed a prospective study in healthy volunteers aimed at evaluating the accuracy, the precision and the trending ability of measurements of ExSpiron®Xi as compared with the gold standard (i.e. spirometry). Further, we explored whether the differences between the 2 devices would be improved by the calibration of ExSpiron®Xi with a pre-determined tidal volume. Analysis accounted for the repeated nature of measurements within each subject. We enrolled 13 healthy volunteers, including 5 men and 8 women. Tidal volume, TV/ideal body weight (IBW) and respiratory rate (RR) measured with spirometer (TVSpirometer) and with ExSpiron®Xi (TVExSpiron) showed a robust correlation, while minute ventilation (MV) showed a weak correlation, in both non/calibrated and calibrated steps. The analysis of the agreement showed that non-calibrated TVExSpiron underestimated TVspirometer, while in the calibrated steps, TVExSpiron overestimated TVspirometer. The calibration procedure did not reduce the average absolute difference (error) between TVSpirometer and TVExSpiron. This happened similarly for TV/IBW and MV, while RR showed high accuracy and precision. The trending ability was excellent for TV, TV/IBW and RR. The concordance rate (CR) was >95% in both calibrated and non-calibrated measurements. The trending ability of minute ventilation was limited. Absolute error for both calibrated and not calibrated values of TV, TV/IBW and MV accounting for repeated measurements was variably associated with BMI, height and smoking status. Conclusions: Non-invasive TV, TV/IBW and RR estimation by ExSpiron®Xi was strongly correlated with tidal ventilation according to the gold standard spirometer technique. This data was not confirmed for MV. The calibration of the device did not improve its performance. Although the accuracy of ExSpiron®Xi was mild and the precision was limited for TV, TV/IBW and MV, the trending ability of the device was strong specifically for TV, TV/IBW and RR. This makes ExSpiron®Xi a non-invasive monitoring system that may detect real-time tidal volume ventilation changes and then suggest the need to better optimize the patient ventilatory support.


Assuntos
Respiração , Masculino , Humanos , Feminino , Estudos Prospectivos , Voluntários Saudáveis , Volume de Ventilação Pulmonar , Medidas de Volume Pulmonar/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...