Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96.919
Filtrar
1.
Radiol Med ; 129(7): 989-998, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38987501

RESUMO

PURPOSE: Contrast-enhanced mammography (CEM) is an innovative imaging tool for breast cancer detection, involving intravenous injection of a contrast medium and the assessment of lesion enhancement in two phases: early and delayed. The aim of the study was to analyze the topographic concordance of lesions detected in the early- versus delayed phase acquisitions. MATERIALS AND METHODS: Approved by the Ethics Committee (No. 118/20), this prospective study included 100 women with histopathological confirmed breast neoplasia (B6) at the Radiodiagnostics Department of the Maggiore della Carità Hospital of Novara, Italy from May 1, 2021, to October 17, 2022. Participants underwent CEM examinations using a complete protocol, encompassing both early- and delayed image acquisitions. Three experienced radiologists blindly analyzed the CEM images for contrast enhancement to determine the topographic concordance of the identified lesions. Two readers assessed the complete study (protocol A), while one reader assessed the protocol without the delayed phase (protocol B). The average glandular dose (AGD) of the entire procedure was also evaluated. RESULTS: The analysis demonstrated high concordance among the three readers in the topographical identification of lesions within individual quadrants of both breasts, with a Cohen's κ > 0.75, except for the lower inner quadrant of the right breast and the retro-areolar region of the left breast. The mean whole AGD was 29.2 mGy. The mean AGD due to CEM amounted to 73% of the whole AGD (21.2 mGy). The AGD attributable to the delayed phase of CEM contributed to 36% of the whole AGD (10.5 mGy). CONCLUSIONS: As we found no significant discrepancy between the readings of the two protocols, we conclude that delayed-phase image acquisition in CEM does not provide essential diagnostic benefits for effective disease management. Instead, it contributes to unnecessary radiation exposure.


Assuntos
Neoplasias da Mama , Meios de Contraste , Mamografia , Estadiamento de Neoplasias , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mamografia/métodos , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos
2.
Theranostics ; 14(10): 4076-4089, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38994029

RESUMO

Metastatic tumours in the brain now represent one of the leading causes of death from cancer. Current treatments are largely ineffective owing to the combination of late diagnosis and poor delivery of therapies across the blood-brain barrier (BBB). Conjugating magnetic resonance imaging (MRI) contrast agents with a monoclonal antibody for VCAM-1 (anti-VCAM1) has been shown to enable detection of micrometastases, two to three orders of magnitude smaller in volume than those currently detectable clinically. The aim of this study was to exploit this targeting approach to enable localised and temporary BBB opening at the site of early-stage metastases using functionalised microbubbles and ultrasound. Methods: Microbubbles functionalised with anti-VCAM1 were synthesised and shown to bind to VCAM-1-expressing cells in vitro. Experiments were then conducted in vivo in a unilateral breast cancer brain metastasis mouse model using Gadolinium-DTPA (Gd-DTPA) enhanced MRI to detect BBB opening. Following injection of Gd-DTPA and targeted microbubbles, the whole brain volume was simultaneously exposed to ultrasound (0.5 MHz, 10% duty cycle, 0.7 MPa peak negative pressure, 2 min treatment time). T1-weighted MRI was then performed to identify BBB opening, followed by histological confirmation via immunoglobulin G (IgG) immunohistochemistry. Results: In mice treated with targeted microbubbles and ultrasound, statistically significantly greater extravasation of Gd-DTPA and IgG was observed in the left tumour-bearing hemisphere compared to the right hemisphere 5 min after treatment. No acute adverse effects were observed. There was no investigation of longer term bioeffects owing to the nature of the study. Conclusion: The results demonstrate the feasibility of using targeted microbubbles in combination with low intensity ultrasound to localise opening of the BBB to metastatic sites in the brain. This approach has potential application in the treatment of metastatic tumours whose location cannot be established a priori with conventional imaging methods.


Assuntos
Barreira Hematoencefálica , Neoplasias Encefálicas , Imageamento por Ressonância Magnética , Microbolhas , Molécula 1 de Adesão de Célula Vascular , Animais , Barreira Hematoencefálica/metabolismo , Barreira Hematoencefálica/diagnóstico por imagem , Camundongos , Neoplasias Encefálicas/diagnóstico por imagem , Molécula 1 de Adesão de Célula Vascular/metabolismo , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Feminino , Modelos Animais de Doenças , Ultrassonografia/métodos , Linhagem Celular Tumoral , Gadolínio DTPA/administração & dosagem , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/metabolismo
3.
Radiol Cardiothorac Imaging ; 6(4): e230338, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39023374

RESUMO

Purpose To investigate whether infarct-to-remote myocardial contrast can be optimized by replacing generic fitting algorithms used to obtain native T1 maps with a data-driven machine learning pixel-wise approach in chronic reperfused infarct in a canine model. Materials and Methods A controlled large animal model (24 canines, equal male and female animals) of chronic myocardial infarction with histologic evidence of heterogeneous infarct tissue composition was studied. Unsupervised clustering techniques using self-organizing maps and t-distributed stochastic neighbor embedding were used to analyze and visualize native T1-weighted pixel-intensity patterns. Deep neural network models were trained to map pixel-intensity patterns from native T1-weighted image series to corresponding pixels on late gadolinium enhancement (LGE) images, yielding visually enhanced noncontrast maps, a process referred to as data-driven native mapping (DNM). Pearson correlation coefficients and Bland-Altman analyses were used to compare findings from the DNM approach against standard T1 maps. Results Native T1-weighted images exhibited distinct pixel-intensity patterns between infarcted and remote territories. Granular pattern visualization revealed higher infarct-to-remote cluster separability with LGE labeling as compared with native T1 maps. Apparent contrast-to-noise ratio from DNM (mean, 15.01 ± 2.88 [SD]) was significantly different from native T1 maps (5.64 ± 1.58; P < .001) but similar to LGE contrast-to-noise ratio (15.51 ± 2.43; P = .40). Infarcted areas based on LGE were more strongly correlated with DNM compared with native T1 maps (R2 = 0.71 for native T1 maps vs LGE; R2 = 0.85 for DNM vs LGE; P < .001). Conclusion Native T1-weighted pixels carry information that can be extracted with the proposed DNM approach to maximize image contrast between infarct and remote territories for enhanced visualization of chronic infarct territories. Keywords: Chronic Myocardial Infarction, Cardiac MRI, Data-Driven Native Contrast Mapping Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Meios de Contraste , Infarto do Miocárdio , Animais , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Feminino , Masculino , Cães , Modelos Animais de Doenças , Imageamento por Ressonância Magnética/métodos , Doença Crônica , Reprodutibilidade dos Testes , Algoritmos
4.
Radiol Cardiothorac Imaging ; 6(4): e230328, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39023373

RESUMO

Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Doença da Artéria Coronariana , Imagens de Fantasmas , Placa Aterosclerótica , Humanos , Masculino , Feminino , Estudos Prospectivos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Idoso , Fótons , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Angiografia Coronária/métodos , Meios de Contraste
5.
Langenbecks Arch Surg ; 409(1): 219, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023574

RESUMO

PURPOSE: This study aims to evaluate the efficacy of admission contrast-enhanced CT scans in formulating strategies for performing early laparoscopic cholecystectomy in cases of acute gallstone pancreatitis. METHODS: Patients diagnosed with acute gallstone pancreatitis underwent a CT scan upon admission (after at least 24 h from symptom onset) to confirm diagnosis and assess peripancreatic fluid, collections, gallstones, and common bile duct stones. Patients with mild acute gallstone pancreatitis, following the Atlanta classification and Baltazar score A or B, were identified as candidates for early cholecystectomy (within 72 h of admission). RESULTS: Within the analyzed period, 272 patients were diagnosed with mild acute gallstone pancreatitis according to the Atlanta Guidelines. A total of 33 patients (12.1%) were excluded: 17 (6.25%) due to SIRS, 10 (3.6%) due to local complications identified in CT (Balthazar D/E), and 6 (2.2%) due to severe comorbidities. Enhanced CT scans accurately detected gallstones, common bile duct stones, pancreatic enlargement, inflammation, pancreatic collections, and peripancreatic fluid. Among the cohort, 239 patients were selected for early laparoscopic cholecystectomy. Routine intraoperative cholangiogram was conducted in all cases, and where choledocholithiasis was present, successful treatment occurred through common bile duct exploration. Only one case required conversion from laparoscopic to open surgery. There were no observed severe complications or mortality. CONCLUSION: Admission CT scans are instrumental in identifying clinically stable patients with local tomographic complications that contraindicate early surgery. Patients meeting the criteria for mild acute gallstone pancreatitis, as per Atlanta guidelines, without SIRS or local complications (Baltazar D/E), can safely undergo early cholecystectomy within the initial 72 h of admission.


Assuntos
Colecistectomia Laparoscópica , Meios de Contraste , Cálculos Biliares , Pancreatite , Tomografia Computadorizada por Raios X , Humanos , Cálculos Biliares/cirurgia , Cálculos Biliares/diagnóstico por imagem , Cálculos Biliares/complicações , Feminino , Masculino , Pancreatite/diagnóstico por imagem , Pancreatite/cirurgia , Pancreatite/complicações , Pessoa de Meia-Idade , Adulto , Idoso , Doença Aguda , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Índice de Gravidade de Doença , Resultado do Tratamento
6.
J Cancer Res Ther ; 20(3): 793-801, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-39023585

RESUMO

BACKGROUND AND AIM: Accurate interpretation of post-treatment imaging in head and neck malignancies poses a challenge due to treatment sequelae. Magnetic resonance (MR) perfusion helps in this scenario by evaluating the hemodynamic characteristics of lesions. This study aimed to elucidate the diagnostic efficacy of dynamic contrast-enhanced (DCE)-MR perfusion imaging in detecting recurrence in patients after they underwent definitive treatment for head and neck tumors. MATERIALS AND METHODS: Thirty patients who had received definitive curative-intent treatment for histopathology-proven malignant head and neck tumors and in whom recurrent tumor was detected on precontrast MR imaging (MRI) were accrued in the study. Patients underwent DCE-MR perfusion imaging. Time to peak (TTP), relative maximum enhancement (RME), and relative washout (RWO) ratio were calculated by using time-intensity curve (TIC). The diagnostic accuracy was compared with histopathology. RESULTS: A cut-off value of ≥125.3 for RME showed a sensitivity of 76.2% and specificity of 66.7% for differentiating post-radiation changes and recurrence. The optimal cut-off for RWO ratio was ≥-6.24 with a sensitivity of 76.2% and specificity of 55.6%. The optimal cut-off of TTP was ≤45.8 s with a sensitivity of 61.9% and specificity of 77.8%. Diagnostic accuracies of RME, RWO, and TTP were 73.3%, 70%, and 66.7%, respectively. CONCLUSIONS: DCE-MRI had significant diagnostic accuracy in detecting and differentiating recurrences. TIC analysis of high-temporal resolution DCE-MRI can provide information regarding microcirculation of tumors, and hence can be considered as an imaging modality of choice for assessment of early local tumor recurrence in head and neck tumors.


Assuntos
Meios de Contraste , Neoplasias de Cabeça e Pescoço , Recidiva Local de Neoplasia , Humanos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/terapia , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adulto , Imageamento por Ressonância Magnética/métodos , Curva ROC , Angiografia por Ressonância Magnética/métodos , Imagem de Perfusão/métodos
7.
BMC Nephrol ; 25(1): 226, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39009991

RESUMO

BACKGROUND: Contrast-induced acute kidney injury (CI-AKI) is an acute renal complication that occurs after intravascular contrast agent administration. Sodium selenite (SS) is an inorganic source of Se and has potent antioxidant properties. This study intends to examine its anti-inflammatory and antioxidant effects in CI-AKI. METHODS: A rat CI-AKI model was established with the pretreatment of SS (0.35 mg/kg). Hematoxylin-eosin staining was employed for histopathological analysis of rat kidney specimens. Biochemical analysis was conducted for renal function detection. Tissue levels of oxidative stress-related markers were estimated. Reverse transcription-quantitative polymerase chain reaction revealed the mRNA levels of proinflammatory cytokines. Western blotting showed the Nrf2 signaling-related protein expression in the rat kidney. RESULTS: SS administration alleviated the renal pathological changes and reduced the serum levels of serum creatinine, blood urea nitrogen, neutrophil gelatinase-associated lipocalin, cystatin C, and urinary level of kidney injury molecule-1 in CI-AKI rats. SS attenuated oxidative stress and inflammatory response in CI-AKI rat kidney tissues. SS activated the Nrf2 signaling transduction in the renal tissues of rats with CI-AKI. CONCLUSION: SS ameliorates CI-AKI in rats by reducing oxidative stress and inflammation via the Nrf2 signaling.


Assuntos
Injúria Renal Aguda , Meios de Contraste , Fator 2 Relacionado a NF-E2 , Estresse Oxidativo , Ratos Sprague-Dawley , Transdução de Sinais , Selenito de Sódio , Animais , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/metabolismo , Injúria Renal Aguda/prevenção & controle , Injúria Renal Aguda/patologia , Estresse Oxidativo/efeitos dos fármacos , Fator 2 Relacionado a NF-E2/metabolismo , Ratos , Masculino , Meios de Contraste/efeitos adversos , Transdução de Sinais/efeitos dos fármacos , Selenito de Sódio/farmacologia , Selenito de Sódio/uso terapêutico , Elementos de Resposta Antioxidante , Inflamação/metabolismo , Antioxidantes/farmacologia , Antioxidantes/uso terapêutico , Creatinina/sangue
8.
Front Endocrinol (Lausanne) ; 15: 1417449, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38952390

RESUMO

Contrast-enhanced ultrasonography (CEUS) has been established as a diagnostic tool for assessing microvascularization, essential for understanding angiogenesis in neoplastic development. AIM: This study assesses the effectiveness of CEUS as a supplementary tool to TIRADS in enhancing the ultrasound-based diagnosis of thyroid cancer. METHODS AND MATERIALS: Over one year, 157 nodules in 133 patients, with predominantly solid thyroid nodules, were examined using ultrasound and CEUS and underwent thyroidectomy, allowing for a comparison of ultrasound findings with pathological reports. RESULTS: Thyroid cancer was identified in 31.21% (49/157) of cases. Significant CEUS high-risk features included inhomogeneous enhancement, enhancement defects, and complete hypoenhancement (AUC 0.818, 0.767, 0.864 respectively). Nodules exhibiting any of these features were classified as high-risk in CEUS. The diagnostic performance of TIRADS improved when combined with CEUS, with AUC increasing from 0.707 to 0.840 and improved sensitivity. CONCLUSION: The integration of CEUS with TIRADS significantly enhances the diagnostic accuracy and specificity in identifying thyroid cancer. This combination proves to be a more effective method for risk stratification and diagnosis, highlighting the value of CEUS as an adjunctive tool in thyroid cancer evaluation.


Assuntos
Meios de Contraste , Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Ultrassonografia , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Masculino , Feminino , Ultrassonografia/métodos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/patologia , Pessoa de Meia-Idade , Adulto , Idoso , Tireoidectomia
9.
Can J Gastroenterol Hepatol ; 2024: 6623848, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38947874

RESUMO

Purpose: To use hepatic uptake index (HUI) of liver lobes on gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) to discriminate between patients with hepatitis B-related cirrhosis in compensated and decompensated statuses. Methods: Forty-four consecutive patients with hepatitis B-related cirrhosis who underwent Gd-EOB-DTPA-enhanced MRI were divided into compensated and decompensated statuses based on clinical evaluation. Volume and signal intensity of individual lobes were retrospectively measured to calculate HUI of the right liver lobe (RHUI), medial (MHUI) and lateral (LHUI) left liver lobes, and caudate lobe (CHUI). Spearman's rank correlation analyses were performed to evaluate relationships of lobe-based HUI with Child-Pugh and model for end-stage liver disease (MELD) scoring system scores in compensated and decompensated statuses. The Mann-Whitney U-test was used to compare the lobe-based HUI between compensated and decompensated statuses. The performance of lobe-based HUI in distinguishing cirrhosis was evaluated using receiver operating characteristic (ROC) analysis, and the area under the ROC curve (AUC) was calculated as a measure of accuracy. Delong's method was used for statistical analysis to elucidate which HUI is optimal. Results: Compensated and decompensated liver cirrhosis were confirmed in 25 (56.82%) and 19 (43.18%) patients, respectively. According to Spearman's rank correlation analysis, RHUI, MHUI, LHUI, and CHUI were all significantly associated with Child-Pugh and MELD scores (all P values <0.05). Receiver operating characteristic analysis demonstrated that among all lobe-based HUI parameters, RHUI could best perform the previous discrimination with a cut-off of 485.73 and obtain an AUC of 0.867. The AUC of RHUI improved and was significantly different from that of MHUI, LHUI, and CHUI (P = 0.03, P = 0.007, and P < 0.001, respectively, Delong's test). Conclusions: The RHUI could help quantitatively discriminate hepatitis B-related cirrhosis between compensated and decompensated statuses.


Assuntos
Meios de Contraste , Gadolínio DTPA , Cirrose Hepática , Fígado , Imageamento por Ressonância Magnética , Humanos , Gadolínio DTPA/farmacocinética , Gadolínio DTPA/administração & dosagem , Cirrose Hepática/diagnóstico por imagem , Feminino , Masculino , Meios de Contraste/farmacocinética , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Adulto , Curva ROC , Idoso , Índice de Gravidade de Doença , Hepatite B/complicações , Hepatite B/diagnóstico por imagem
10.
Front Endocrinol (Lausanne) ; 15: 1390868, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38957440

RESUMO

Purpose: Both glucose and albumin are associated with chronic inflammation, which plays a vital role in post-contrast acute kidney injury (PC-AKI). To explore the relationship between random glucose to albumin ratio (RAR) and the incidence of PC-AKI after percutaneous coronary intervention (PCI) in patients with ST-elevation myocardial infarction (STEMI). Patients and methods: STEMI patients who underwent PCI were consecutively enrolled from January, 01, 2010 to February, 28, 2020. All patients were categorized into T1, T2, and T3 groups, respectively, based on RAR value (RAR < 3.377; 3.377 ≤ RAR ≤ 4.579; RAR > 4.579). The primary outcome was the incidence of PC-AKI, and the incidence of major adverse clinical events (MACE) was the second endpoint. The association between RAR and PC-AKI was assessed by multivariable logistic regression analysis. Results: A total of 2,924 patients with STEMI undergoing PCI were finally included. The incidence of PC-AKI increased with the increasing tertile of RAR (3.2% vs 4.8% vs 10.6%, P<0.001). Multivariable regression analysis demonstrated that RAR (as a continuous variable) was associated with the incidence of PC-AKI (adjusted odds ratio (OR) =1.10, 95% confidence interval (CI) =1.04 - 1.16, P<0.001) and in-hospital MACE (OR=1.07, 95% CI=1.02 - 1.14, P=0.012); RAR, as a categorical variable, was significantly associated with PC-AKI (T3 vs. T1, OR=1.70, 95% CI=1.08 - 2.67, P=0.021) and in-hospital MACE (T3 vs. T1, OR=1.63, 95% CI=1.02 - 2.60, P=0.041) in multivariable regression analyses. Receiver operating characteristic curve analysis showed that RAR exhibited a predictive value for PC-AKI (area under the curve (AUC)=0.666, 95% CI=0.625 - 0.708), and in-hospital MACE (AUC= 0.662, 95% CI =0.619 - 0.706). Conclusions: The high value of RAR was significantly associated with the increasing risk of PC-AKI and in-hospital MACE after PCI in STEMI patients, and RAR offers a good predictive value for those outcomes.


Assuntos
Injúria Renal Aguda , Meios de Contraste , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/sangue , Feminino , Masculino , Infarto do Miocárdio com Supradesnível do Segmento ST/sangue , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Pessoa de Meia-Idade , Meios de Contraste/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Idoso , Glicemia/análise , Incidência , Albumina Sérica/análise , Albumina Sérica/metabolismo , Estudos Retrospectivos , Fatores de Risco , Prognóstico
11.
Pharmacol Res Perspect ; 12(4): e1228, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38956898

RESUMO

Contrast-induced nephropathy (CIN) is a serious complication that occurs subsequent to the administration of contrast media for therapeutic angiographic interventions. As of present, no effective therapy exists to prevent its occurrence. This single-center double-blind randomized controlled trial aimed to evaluate the effect of edaravone, an antioxidant, in a group of high-risk patients undergoing coronary angiography. Ninety eligible patients with chronic kidney disease Stages 3-4 were randomly assigned to either the control group (n = 45) or the intervention group (n = 45). In the intervention group, one dosage of edaravone (60 mg) in 1 L of normal saline was infused via a peripheral vein 1 h prior to femoral artery-directed coronary angiography. Patients in the control group received an equal amount of infusion in their last hour before angiography. Both groups received intravenous hydration with 0.9% sodium 1 mL/kg/h starting 12 h before and continuing for 24 h after angiography. The primary outcome measure was the onset of CIN, defined as a 25% increase in serum creatinine levels 120 h after administration of contrast media. The occurrence of CIN was observed in 5.5% (n = 5) of the studied population: 2.2% of patients in the intervention group (n = 1) and 8.9% of controls (n = 4). However, this difference was not statistically significant. Administration of a single dosage of edaravone 1 h prior to infusion of contrast media led to a reduction in the incidence of CIN. Further investigations, employing larger sample sizes, are warranted to gain a comprehensive understanding of its efficacy.


Assuntos
Meios de Contraste , Angiografia Coronária , Edaravone , Humanos , Edaravone/uso terapêutico , Edaravone/administração & dosagem , Método Duplo-Cego , Meios de Contraste/efeitos adversos , Masculino , Feminino , Angiografia Coronária/efeitos adversos , Pessoa de Meia-Idade , Idoso , Sequestradores de Radicais Livres/uso terapêutico , Sequestradores de Radicais Livres/administração & dosagem , Creatinina/sangue , Nefropatias/induzido quimicamente , Nefropatias/prevenção & controle , Antipirina/análogos & derivados , Antipirina/uso terapêutico , Resultado do Tratamento
12.
Nihon Shokakibyo Gakkai Zasshi ; 121(7): 605-614, 2024.
Artigo em Japonês | MEDLINE | ID: mdl-38987171

RESUMO

A man in his 60s with hyperamylasemia underwent contrast-enhanced computed tomography, which revealed masses in his pelvic cavity on the right side and in the left axilla. Hence, a detailed examination was performed. Upon performing Sonazoid® (perfluorobutane) contrast-enhanced ultrasound, it was discovered that the right-sided pelvic cavity mass exhibited centripetal contrast-enhancement right from the early stage. Subsequently, the contrast material disappeared from the center and was washed out in the postvascular phase. The mass was suspected to be caused by vascular malformations. The right-sided pelvic cavity mass was excised, and upon histopathological examination, it was detected to be composed of capillary malformations. Thus, it was found that Sonazoid® contrast-enhanced ultrasound examination could aid in diagnosing retroperitoneal masses.


Assuntos
Meios de Contraste , Compostos Férricos , Ferro , Óxidos , Ultrassonografia , Humanos , Masculino , Fluorocarbonos , Espaço Retroperitoneal/diagnóstico por imagem , Capilares/diagnóstico por imagem , Capilares/anormalidades , Capilares/patologia , Malformações Vasculares/diagnóstico por imagem , Pessoa de Meia-Idade
13.
Sci Rep ; 14(1): 15861, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38982273

RESUMO

The purpose of this study was to investigate the relationship between Inflammatory Prognostic Index (IPI) levels and Contrast-Induced Nephropathy (CIN) risk and postoperative clinical outcomes in patients undergoing coronary angiography (CAG) and/or percutaneous coronary intervention (PCI). A total of 3,340 consecutive patients who underwent CAG and/or PCI between May 2017 and December 2022 were enrolled in this study. Based on their baseline IPI levels, patients were categorized into four groups. Clinical characteristics and postoperative outcomes were compared among these groups. In-hospital outcomes focused on CIN risk, repeated revascularization, major bleeding, and major adverse cardiovascular events (MACEs), while the long-term outcome examined the all-cause readmission rate. Quartile analysis found a significant link between IPI levels and CIN risk, notably in the highest quartile (P < 0.001). Even after adjusting for baseline factors, this association remained significant, with an adjusted Odds Ratio (aOR) of 2.33 (95%CI 1.50-3.64; P = 0.001). Notably, baseline IPI level emerged as an independent predictor of severe arrhythmia, with aOR of 0.50 (95%CI 0.35-0.69; P < 0.001), particularly driven by the highest quartile. Furthermore, a significant correlation between IPI and acute myocardial infarction was observed (P < 0.001), which remained significant post-adjustment. For patients undergoing CAG and/or PCI, baseline IPI levels can independently predict clinical prognosis. As a comprehensive inflammation indicator, IPI effectively identifies high-risk patients post-procedure. This study underscores IPI's potential to assist medical professionals in making more precise clinical decisions, ultimately reducing mortality and readmission rates linked to cardiovascular disease (CVD).


Assuntos
Meios de Contraste , Angiografia Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Masculino , Feminino , Angiografia Coronária/efeitos adversos , Meios de Contraste/efeitos adversos , Idoso , Prognóstico , Pessoa de Meia-Idade , Inflamação , Nefropatias/induzido quimicamente , Fatores de Risco , Valor Preditivo dos Testes , Estudos Retrospectivos
14.
Nat Commun ; 15(1): 5832, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38992020

RESUMO

While second near-infrared (NIR-II) fluorescence imaging is a promising tool for real-time surveillance of surgical operations, the previously reported organic NIR-II luminescent materials for in vivo imaging are predominantly activated by expensive lasers or X-ray with high power and poor illumination homogeneity, which significantly limits their clinical applications. Here we report a white-light activatable NIR-II organic imaging agent by taking advantages of the strong intramolecular/intermolecular D-A interactions of conjugated Y6CT molecules in nanoparticles (Y6CT-NPs), with the brightness of as high as 13315.1, which is over two times that of the brightest laser-activated NIR-II organic contrast agents reported thus far. Upon white-light activation, Y6CT-NPs can achieve not only in vivo imaging of hepatic ischemia reperfusion, but also real-time monitoring of kidney transplantation surgery. During the surgery, identification of the renal vasculature, post-reconstruction assessment of renal allograft vascular integrity, and blood supply analysis of the ureter can be vividly depicted by using Y6CT-NPs with high signal-to-noise ratios upon clinical laparoscopic LED white-light activation. Our work provides efficient molecular design guidelines towards white-light activatable imaging agent and highlights an opportunity for precision imaging theranostics.


Assuntos
Imagem Óptica , Cirurgia Assistida por Computador , Animais , Cirurgia Assistida por Computador/métodos , Camundongos , Imagem Óptica/métodos , Luz , Nanoestruturas/química , Transplante de Rim/métodos , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Nanopartículas/química , Raios Infravermelhos , Luminescência , Rim/diagnóstico por imagem , Rim/cirurgia , Masculino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Meios de Contraste/química
15.
Cancer Imaging ; 24(1): 93, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38992707

RESUMO

BACKGROUND: Dynamic contrast-enhanced-MRI (DCE-MRI) is able to study bone marrow angiogenesis in patients with multiple myeloma (MM) and asymptomatic precursor diseases but its role in the management of MM has not yet been established. The aims of this prospective study was to compare DCE-MRI-based parameters between all monoclonal plasma cell disease stages in order to find out discriminatory parameters and to seek correlations with other diffusion-weighted MRI and positron emission tomography (PET)-based biomarkers in a hybrid simultaneous whole-body-2-[18F]fluorodeoxyglucose (FDG)-PET/MRI (WB-2-[18F]FDG-PET/MRI) imaging approach. METHODS: Patients with newly diagnosed Monoclonal gammopathy of undetermined significance (MGUS), smoldering multiple myeloma (SMM) or symptomatic MM according to international myeloma working group and underwent WB-2-[18F]FDG-PET/MRI imaging including bone marrow DCE sequences at the Nantes University Hospital were prospectively enrolled in this study before receiving treatment. RESULTS: One hundred and sixty-seven patients (N = 167, mean age: 64 years ± 11 [Standard deviation], 66 males) were considered for the analysis. DCE-MRI-based Peak Enhancement Intensity (PEI), Time to PEI (TPEI) and their maximum intensity time ratio (MITR: PEI/TPEI) values were significantly different between the different monoclonal plasma cell disease stages, PEI values increasing and TPEI values decreasing progressively along the spectrum of plasma cell disorders, from MGUS stage to symptomatic multiple myeloma. PEI values were significantly higher in patients with diffuse bone marrow involvement (either in PET or in MRI images) than in those without diffuse bone marrow involvement, unlike TPEI values. PEI and TPEI values were not significantly different between patients with or without focal bone lesions. CONCLUSION: Different DCE-MRI-based parameters (PEI, TPEI, MITR) could significantly differentiate all monoclonal plasma cell disease stages and complemented conventional MRI and PET-based biomarkers.


Assuntos
Imagem de Difusão por Ressonância Magnética , Fluordesoxiglucose F18 , Mieloma Múltiplo , Tomografia por Emissão de Pósitrons , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Mieloma Múltiplo/diagnóstico por imagem , Estudos Prospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Gamopatia Monoclonal de Significância Indeterminada/diagnóstico por imagem , Meios de Contraste , Imagem Multimodal/métodos , Compostos Radiofarmacêuticos , Imagem Corporal Total/métodos , Idoso de 80 Anos ou mais , Medula Óssea/diagnóstico por imagem , Medula Óssea/patologia
16.
Sci Adv ; 10(28): eado2483, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38996017

RESUMO

Noninvasive tracking of biochemical processes in the body is paramount in diagnostic medicine. Among the leading techniques is spectroscopic magnetic resonance imaging (MRI), which tracks metabolites with an amplified (hyperpolarized) magnetization signal injected into the subject just before scanning. Traditionally, the brief enhanced magnetization period of these agents limited clinical imaging. We propose a solution based on amalgamating two materials-one having diagnostic-metabolic activity and the other characterized by robust magnetization retention. This combination slows the magnetization decay in the diagnostic metabolic probe, which receives continuously replenished magnetization from the companion material. Thus, it extends the magnetization lifetime in some of our measurements to beyond 4 min, with net magnetization enhanced by more than four orders of magnitude. This could allow the metabolic probes to remain magnetized from injection until they reach the targeted organ, improving tissue signatures in clinical imaging. Upon validation, this metabolic MRI technique promises wide-ranging clinical applications, including diagnostic imaging, therapeutic monitoring, and posttreatment surveillance.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Meios de Contraste/química , Humanos , Animais , Magnetismo
17.
Int J Mol Sci ; 25(13)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-39000268

RESUMO

Current clinical diagnostic imaging methods for lung metastases are sensitive only to large tumours (1-2 mm cross-sectional diameter), and early detection can dramatically improve treatment. We have previously demonstrated that an antibody-targeted MRI contrast agent based on microparticles of iron oxide (MPIO; 1 µm diameter) enables the imaging of endothelial vascular cell adhesion molecule-1 (VCAM-1). Using a mouse model of lung metastasis, upregulation of endothelial VCAM-1 expression was demonstrated in micrometastasis-associated vessels but not in normal lung tissue, and binding of VCAM-MPIO to these vessels was evident histologically. Owing to the lack of proton MRI signals in the lungs, we modified the VCAM-MPIO to include zirconium-89 (89Zr, t1/2 = 78.4 h) in order to allow the in vivo detection of lung metastases by positron emission tomography (PET). Using this new agent (89Zr-DFO-VCAM-MPIO), it was possible to detect the presence of micrometastases within the lung in vivo from ca. 140 µm in diameter. Histological analysis combined with autoradiography confirmed the specific binding of the agent to the VCAM-1 expressing vasculature at the sites of pulmonary micrometastases. By retaining the original VCAM-MPIO as the basis for this new molecular contrast agent, we have created a dual-modality (PET/MRI) agent for the concurrent detection of lung and brain micrometastases.


Assuntos
Meios de Contraste , Neoplasias Pulmonares , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Molécula 1 de Adesão de Célula Vascular , Zircônio , Animais , Molécula 1 de Adesão de Célula Vascular/metabolismo , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/metabolismo , Imageamento por Ressonância Magnética/métodos , Camundongos , Tomografia por Emissão de Pósitrons/métodos , Micrometástase de Neoplasia/diagnóstico por imagem , Compostos Férricos/química , Humanos , Linhagem Celular Tumoral , Radioisótopos
18.
Echocardiography ; 41(8): e15886, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39007877

RESUMO

BACKGROUND: Due to insufficient near-field resolution and artifacts, it is challenging to evaluate the left ventricular apical perfusion with phased-array probes. By combining high-frequency linear probe and contrast-enhanced ultrasound (CEUS), imaging of apical myocardial perfusion could be improved. The study aims to evaluate the preliminary application of CEUS by high-frequency linear probes to assess the apical perfusion. METHODS: The study enrolled retrospectively 91 patients to test the feasibility of the novel method. In protocol 1, patients were stratified into a group with left anterior descending artery (LAD) stenosis (N = 40) and a group without LAD stenosis or coronary artery disease (N = 41) based on the degree of coronary artery narrowing, quantified by >50% stenosis in coronary angiography. Receiver operating characteristics (ROC) analysis was performed to test the diagnostic value of perfusion parameters. In protocol 2, the reproducibility of high-frequency linear probe in apical perfusion analysis was compared with the conventional phased-array probe in 30 patients. RESULTS: (1) The novel method is feasible in 81(89.01%) patients. (2) In protocol 1, to detect LAD stenosis, the best cut-off of ß, T, A, and MBF were 10.32, 3.28, 9.39, and 4.99, respectively. Area under the curve of ß, T, A, and MBF were .880, .881, .761, and .880, respectively. (3) In protocol 2, compared with phased-array probe, the quantitative analysis of high-frequency linear probe is of high reproducibility and could get good curve fitting (R2 = .29 vs. R2 = .71, P < .01). CONCLUSION: Observation of apical perfusion using this method is feasible and quantitative analysis allows an accurate and convenient identification of LAD stenosis. This method provides an alternative for patients who have difficulties in visualizing the apical region with a phased-array probe.


Assuntos
Meios de Contraste , Estudos de Viabilidade , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Ecocardiografia/métodos , Aumento da Imagem/métodos , Idoso , Sensibilidade e Especificidade , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Desenho de Equipamento
19.
PLoS One ; 19(7): e0303957, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38950083

RESUMO

BACKGROUND: The placenta is a transient organ critical for fetal development. Disruptions of normal placental functions can impact health throughout an individual's entire life. Although being recognized by the NIH Human Placenta Project as an important organ, the placenta remains understudied, partly because of a lack of non-invasive tools for longitudinally evaluation for key aspects of placental functionalities. OBJECTIVE: Our goal is to create a non-invasive preclinical imaging pipeline that can longitudinally probe murine placental health in vivo. We use advanced imaging processing schemes to establish functional biomarkers for non-invasive longitudinal evaluation of placental development. METHODOLOGY: We implement dynamic contrast enhancement magnetic resonance imaging (DCE-MRI) and analysis pipeline to quantify uterine contraction and placental perfusion dynamics. We use optic flow and time-frequency analysis to quantify and characterize contraction-related placental motion. Our novel imaging and analysis pipeline uses subcutaneous administration of gadolinium for steepest slope-based perfusion evaluation, enabling non-invasive longitudinal monitoring. RESULTS: We demonstrate that the placenta exhibits spatially asymmetric contractile motion that develops from E14.5 to E17.5. Additionally, we see that placental perfusion, perfusion delivery rate, and substrate delivery all increase from E14.5 to E17.5, with the High Perfusion Chamber (HPC) leading the placental changes that occur from E14.5 to E17.5. DISCUSSION: We advance the placental perfusion chamber paradigm with a novel, physiologically based threshold model for chamber localization and demonstrate spatially varying placental chambers using multiple functional metrics that assess mouse placental development and remodeling throughout gestation. CONCLUSION: Our pipeline enables the non-invasive, longitudinal assessment of multiple placenta functions from a single imaging session. Our pipeline serves as a key toolbox for advancing research in mouse models of placental disease and disorder.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Placenta , Contração Uterina , Animais , Feminino , Gravidez , Imageamento por Ressonância Magnética/métodos , Camundongos , Placenta/diagnóstico por imagem , Placenta/irrigação sanguínea , Contração Uterina/fisiologia , Camundongos Endogâmicos C57BL
20.
Sci Rep ; 14(1): 16126, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38997313

RESUMO

Microbubble contrast agents in ultrasound/echocardiography are used to increase the echogenicity of the target tissues, thereby raising the contrast resolution of the resultant image. Recently, the trend has shifted toward the development of phase-convertible nanodroplets as ultrasound contrast agents due to their promising theragnostic potential by switching capability at the active site. Herein, we fabricated pre-PGS- perfluoropentane phase convertible nanodroplets and checked their in vitro and in vivo enhancement and safety profile. For this, we performed experiments on 20 male Wistar rats and 2 dogs. Biochemical assays of both rats and dogs included complete blood profiles, liver function tests, and renal function tests. For rat vitals, monitoring and histopathological analysis were also performed. Converted nanodroplets showed excellent contrast enhancement, better than Sonovue upon in vitro testing, with an enhancement time of up to 14 min. In vivo, experiments showed comparable opacification of the ventricles of both rats and dogs. All biochemical assays remained within the normal range during the study period. The histopathological analysis did not show any signs of drug-induced toxicity, showing the safety of these nanodroplets. Pre-PGS-PFP nanodroplets hold great potential for use in echocardiography and abdominal imaging in both human and veterinary applications after clinical trials.


Assuntos
Meios de Contraste , Ratos Wistar , Ultrassonografia , Animais , Cães , Meios de Contraste/química , Masculino , Ratos , Ultrassonografia/métodos , Nanopartículas/química , Microbolhas , Ecocardiografia/métodos , Fluorocarbonos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...