Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Assoc Nurse Pract ; 31(6): 337-343, 2019 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-30681650

RESUMO

BACKGROUND AND PURPOSE: Prosthetic joint infection (PJI) is a serious complication resulting from total knee arthroplasty (TKA) or total hip arthroplasty (THA). In this study, patients with a PJI are compared with patients with an uncomplicated postoperative course to identify relevant risk factors for PJI. METHODS: A matched case-control study was performed with patients undergoing fast-track, elective unilateral TKA or THA. The following data were collected: demographics, surgery-related characteristics (perioperative blood loss, use of cement, body temperature), and postoperative characteristics (hematoma formation, wound leakage, blood transfusion, length of stay [LOS]). CONCLUSIONS: When the PJI group was compared with the control group, there was significantly more wound leakage during hospital stay (88% vs. 36%, p = .001) and early wound dressing changes in the first 3 days after surgery (88% vs. 40%, p = .002). Hematoma formation was observed more in the PJI patients group (44% vs. 10%, p = .005). A trend test revealed a significant association between the total number of wound dressing changes and development of PJI (p < .001); 72% of PJI patients had a length of stay of ≥4 days compared with 34% of controls (odds ratio 10.5; 95% CI [2.1-52.3]; p = .004). IMPLICATIONS FOR PRACTICE: Early postoperative wound drainage and hematoma formation directly correlate with PJI. This resulted in a significantly higher number of dressing changes and longer LOS. The nurse practitioner has a central role in postoperative care and is the first to recognize signs of an adverse postoperative clinical course.


Assuntos
Membros Artificiais/normas , Drenagem/efeitos adversos , Infecção dos Ferimentos/diagnóstico , Ferimentos e Lesões/microbiologia , Idoso , Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/estatística & dados numéricos , Membros Artificiais/microbiologia , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Fatores de Risco , Infecção dos Ferimentos/fisiopatologia , Ferimentos e Lesões/fisiopatologia
2.
Clin Orthop Relat Res ; 468(10): 2781-8, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20473597

RESUMO

BACKGROUND: The concept of osseointegration involves direct contact between titanium implant and bone. This transcutaneous prosthetic system for amputees is intended to assure stable long-term fixation. Most metal transcutaneous implants have failed, primarily owing to infection. QUESTIONS/PURPOSES: We determined the frequency and describe the presentation of infectious complications with this novel method. We also evaluated the bacterial flora at the skin-penetration area and its relation to the development of local and implant-related infection. PATIENTS AND METHODS: We prospectively followed 39 patients with arm and leg amputations fitted with transcutaneous osseointegrated titanium implants a mean of 56 months earlier (range, 132-133 months). There were 33 femoral, one tibial, four ulnar, four radial, and three humeral implants. Patients were selected during a 6-month period in 2005 and identically reevaluated after 3 years. Implant infection was defined as definite, probable, or possible based on clinical, radiologic, and microbiologic evidence. RESULTS: The frequency of implant infection was 5% at inclusion and 18% at followup. One patient with infection recovered owing to antibiotic treatment and another patient had the implant removed. Most implant infections had low infectious activity, and in five of the seven patients with infections, prosthetic use was not affected. The most common bacteria in superficial and deep cultures were Staphylococcus aureus and coagulase-negative staphylococci. CONCLUSIONS: Despite frequent colonization around the skin-implant interface by potentially virulent bacteria such as Staphylococcus aureus and bacteria associated with biomedical device infections such as coagulase-negative staphylococci, this titanium implant system for bone-anchored prostheses caused few infections leading to disability or implant removal. LEVEL OF EVIDENCE: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Amputação Cirúrgica , Membros Artificiais/microbiologia , Osseointegração , Infecções Relacionadas à Prótese/microbiologia , Infecção da Ferida Cirúrgica/microbiologia , Titânio , Adulto , Idoso , Antibacterianos/uso terapêutico , Remoção de Dispositivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/terapia , Radiografia , Reoperação , Pele/microbiologia , Infecção da Ferida Cirúrgica/diagnóstico por imagem , Infecção da Ferida Cirúrgica/terapia , Suécia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...