Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.270
Filtrar
1.
J Appl Oral Sci ; 32: e20230458, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38922241

RESUMO

OBJECTIVE: This study compared three protocols for developing artificial white spot lesions (WSL) using biofilm models. METHODOLOGY: In total, 45 human enamel specimens were sterilized and allocated into three groups based on the biofilm model: Streptococcus sobrinus and Lactobacillus casei (Ss+Lc), Streptococcus sobrinus (Ss), or Streptococcus mutans (Sm). Specimens were incubated in filter-sterilized human saliva to form the acquired pellicle and then subjected to the biofilm challenge consisting of three days of incubation with bacteria (for demineralization) and one day of remineralization, which was performed once for Ss+Lc (four days total), four times for Ss (16 days total), and three times for Sm (12 days total). After WSL creation, the lesion fluorescence, depth, and chemical composition were assessed using Quantitative Light-induced Fluorescence (QLF), Polarized Light Microscopy (PLM), and Raman Spectroscopy, respectively. Statistical analysis consisted of two-way ANOVA followed by Tukey's post hoc test (α=0.05). WSL created using the Ss+Lc protocol presented statistically significant higher fluorescence loss (ΔF) and integrated fluorescence (ΔQ) in comparison to the other two protocols (p<0.001). RESULTS: In addition, Ss+Lc resulted in significantly deeper WSL (137.5 µm), followed by Ss (84.1 µm) and Sm (54.9 µm) (p<0.001). While high mineral content was observed in sound enamel surrounding the WSL, lesions created with the Ss+Lc protocol showed the highest demineralization level and changes in the mineral content among the three protocols. CONCLUSION: The biofilm model using S. sobrinus and L. casei for four days was the most appropriate and simplified protocol for developing artificial active WSL with lower fluorescence, higher demineralization, and greater depth.


Assuntos
Biofilmes , Cárie Dentária , Esmalte Dentário , Lacticaseibacillus casei , Streptococcus mutans , Humanos , Streptococcus mutans/fisiologia , Cárie Dentária/microbiologia , Cárie Dentária/terapia , Esmalte Dentário/microbiologia , Esmalte Dentário/química , Lacticaseibacillus casei/fisiologia , Fatores de Tempo , Reprodutibilidade dos Testes , Streptococcus sobrinus/fisiologia , Análise Espectral Raman , Análise de Variância , Microscopia de Polarização , Estatísticas não Paramétricas , Remineralização Dentária/métodos , Valores de Referência , Saliva/microbiologia , Saliva/química , Desmineralização do Dente/microbiologia , Fluorescência
2.
Dent Med Probl ; 61(3): 345-352, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38860839

RESUMO

BACKGROUND: Salvadora persica (miswak) is known to exert antibacterial, antifungal, antioxidant, and anticariogenic effects by elevating the pH of plaque after the consumption of sucrose. OBJECTIVES: The study aimed to compare the effectiveness of S. persica and probiotic yogurt in the remineralization of tooth enamel on artificially produced enamel lesions. MATERIAL AND METHODS: A total of 40 intact human premolars were collected and each tooth was sectioned longitudinally into 2 identical halves in a buccolingual direction. The buccal halves were selected for inclusion in this study, and standardized windows (5 mm × 3 mm) were isolated on the buccal surface of the enamel. The samples were incubated in a demineralizing solution at 37°C for 96 h. Subsequently, they were randomly selected for treatment with one of the experimental remineralizing solutions (S. persica or probiotic yogurt). After treatment, the samples were examined using scanning electron microscopy (SEM), energy dispersive X-ray (EDX) and polarized light microscopy at baseline, after demineralization and after remineralization. RESULTS: The remineralizing effect of S. persica was found to be greater than that of probiotic yogurt. With regard to mineral content, S. persica exhibited the highest calcium and phosphorus levels among all groups. No significant differences were observed between the samples treated with S. persica and normal enamel. CONCLUSIONS: Salvadora persica extract has been demonstrated to effectively reduce the demineralization of enamel in experimental conditions. Furthermore, it has the potential to restore the mineral content to its original level.


Assuntos
Esmalte Dentário , Probióticos , Salvadoraceae , Remineralização Dentária , Iogurte , Probióticos/uso terapêutico , Humanos , Iogurte/microbiologia , Esmalte Dentário/efeitos dos fármacos , Microscopia Eletrônica de Varredura , Desmineralização do Dente , Microscopia de Polarização
3.
Opt Lett ; 49(12): 3356-3359, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38875619

RESUMO

Mueller matrix microscopy can provide comprehensive polarization-related optical and structural information of biomedical samples label-freely. Thus, it is regarded as an emerging powerful tool for pathological diagnosis. However, the staining dyes have different optical properties and staining mechanisms, which can put influence on Mueller matrix microscopic measurement. In this Letter, we quantitatively analyze the polarization enhancement mechanism from hematoxylin and eosin (H&E) staining in multispectral Mueller matrix microscopy. We examine the influence of hematoxylin and eosin dyes on Mueller matrix-derived polarization characteristics of fibrous tissue structures. Combined with Monte Carlo simulations, we explain how the dyes enhance diattenuation and linear retardance as the illumination wavelength changed. In addition, it is demonstrated that by choosing an appropriate incident wavelength, more visual Mueller matrix polarimetric information can be observed of the H&E stained tissue sample. The findings can lay the foundation for the future Mueller matrix-assisted digital pathology.


Assuntos
Coloração e Rotulagem , Microscopia de Polarização/métodos , Amarelo de Eosina-(YS)/química , Método de Monte Carlo , Hematoxilina , Humanos
4.
Lasers Med Sci ; 39(1): 123, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38703302

RESUMO

Interaction of polarized light with healthy and abnormal regions of tissue reveals structural information associated with its pathological condition. Even a slight variation in structural alignment can induce a change in polarization property, which can play a crucial role in the early detection of abnormal tissue morphology. We propose a transmission-based Stokes-Mueller microscope for quantitative analysis of the microstructural properties of the tissue specimen. The Stokes-Mueller based polarization microscopy provides significant structural information of tissue through various polarization parameters such as degree of polarization (DOP), degree of linear polarization (DOLP), and degree of circular polarization (DOCP), anisotropy (r) and Mueller decomposition parameters such as diattenuation, retardance and depolarization. Further, by applying a suitable image processing technique such as Machine learning (ML) output images were analysed effectively. The support vector machine image classification model achieved 95.78% validation accuracy and 94.81% testing accuracy with polarization parameter dataset. The study's findings demonstrate the potential of Stokes-Mueller polarimetry in tissue characterization and diagnosis, providing a valuable tool for biomedical applications.


Assuntos
Neoplasias da Mama , Aprendizado de Máquina , Microscopia de Polarização , Humanos , Microscopia de Polarização/métodos , Neoplasias da Mama/patologia , Feminino , Máquina de Vetores de Suporte , Processamento de Imagem Assistida por Computador/métodos , Carcinoma Ductal de Mama/patologia , Carcinoma Ductal de Mama/classificação , Carcinoma Ductal de Mama/diagnóstico por imagem
5.
J Biomed Opt ; 29(6): 065002, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38812963

RESUMO

Significance: Preparation of a recipient cytoplast by oocyte enucleation is an essential task for animal cloning and assisted reproductive technologies in humans. The femtosecond laser is a precise and low-invasive tool for oocyte enucleation, and it should be an appropriate alternative to traditional enucleation by a microneedle aspiration. However, until recently, the laser enucleation was performed only with applying a fluorescent dye. Aim: This work is aimed to (1) achieve femtosecond laser oocyte enucleation without applying a fluorescent dye and (2) to study the effect of laser destruction of chromosomes on the structure and dynamics of the spindle. Approach: We applied polarized light microscopy for spindle visualization and performed stain-free mouse and human oocyte enucleation with a 1033 nm femtosecond laser. Also, we studied transformation of a spindle after metaphase plate elimination by a confocal microscopy. Results: We demonstrated a fundamental possibility of inactivating the metaphase plate in mouse and human oocytes by 1033 nm femtosecond laser radiation without applying a fluorescent dye. Irradiation of the spindle area, visualized by polarized light microscopy, resulted in partly or complete metaphase plate destruction but avoided the microtubules impairment. After the metaphase plate elimination, the spindle reorganized, however, it was not a complete depolymerization. Conclusions: This method of recipient cytoplast preparation is expected to be useful for animal cloning and assisted reproductive technologies.


Assuntos
Oócitos , Animais , Camundongos , Oócitos/citologia , Humanos , Feminino , Lasers , Fuso Acromático , Microscopia Confocal/métodos , Metáfase , Microscopia de Polarização/métodos
6.
Invest Ophthalmol Vis Sci ; 65(4): 35, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38648038

RESUMO

Purpose: The lamina cribrosa (LC) depends on the sclera for support. The support must be provided through the LC insertions. Although a continuous insertion over the whole LC periphery is often assumed, LC insertions are actually discrete locations where LC collagenous beams meet the sclera. We hypothesized that LC insertions vary in number, size, and shape by quadrant and depth. Methods: Coronal cryosections through the full LCs from six healthy monkey eyes were imaged using instant polarized light microscopy. The images were registered into a stack, on which we manually marked LC insertion outlines, nothing their position in-depth and quadrant (inferior, superior, nasal, or temporal). From the marks, we determined the insertion number, width, angle to the canal wall (90 degrees = perpendicular), and insertion ratio (fraction of LC periphery represented by insertions). Using linear mixed effect models, we determined if the insertion characteristics were associated with depth or quadrant. Results: Insertions in the anterior LC were sparser, narrower, and more slanted than those in deeper LC (P values < 0.001). There were more insertions spanning a larger ratio of the canal wall in the middle LC than in the anterior and posterior (P values < 0.001). In the nasal quadrant, the insertion angles were significantly smaller (P < 0.001). Conclusions: LC insertions vary substantially and significantly over the canal. The sparser, narrower, and more slanted insertions of the anterior-most LC may not provide the robust support afforded by insertions of the middle and posterior LC. These variations may contribute to the progressive deepening of the LC and regional susceptibility to glaucoma.


Assuntos
Disco Óptico , Esclera , Esclera/anatomia & histologia , Animais , Disco Óptico/anatomia & histologia , Disco Óptico/diagnóstico por imagem , Microscopia de Polarização , Macaca mulatta , Masculino
7.
Photodiagnosis Photodyn Ther ; 46: 104094, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38642728

RESUMO

OBJECTIVE: Oral cancer is a leading cause of mortality globally, particularly affecting developing regions where oral hygiene is often overlooked. The optical properties of tissues are vital for diagnostics, with polarization imaging emerging as a label-free, contrast-enhancing technique widely employed in medical and scientific research over past few decades. MATERIALS AND METHODS: We present a novel polarization sensitive quantitative phase imaging of biological tissues by incorporating the conventional polarization microscope and transport of intensity equation-based phase retrieval algorithm. This integration provides access to the birefringence mapping of biological tissues. The inherent optical anisotropy in biological tissues induces the polarization dependent refractive index variations which can provide the detailed insights into the birefringence characteristics of their extracellular constituents. Experimental investigations were conducted on both normal and cancerous oral tissue samples by recording a set of three polarization intensity images for each case with a step size of 2 µm. RESULTS: A noteworthy increment in birefringence quantification was observed in cancerous as compared to the normal tissues, attributed to the proliferation of abnormal cells during cancer progression. The mean birefringence values were calculated for both normal and cancerous tissues, revealing a significant increase in birefringence of cancerous tissues (2.1 ± 0.2) × 10-2 compared to normal tissues (0.8 ± 0.2) × 10-2. Data were collected from 8 patients in each group under identical experimental conditions. CONCLUSION: This polarization sensitive non-interferometric optical approach demonstrated effective discrimination between cancerous and normal tissues, with various parameters indicating elevated values in cancerous tissues.


Assuntos
Microscopia de Polarização , Neoplasias Bucais , Birrefringência , Humanos , Microscopia de Polarização/métodos , Neoplasias Bucais/diagnóstico por imagem , Algoritmos , Refratometria/métodos , Imageamento Quantitativo de Fase
8.
Int Orthod ; 22(2): 100865, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38457899

RESUMO

AIM: Fluoride-Amorphous Calcium Phosphate and Biomimetic Nano-Hydroxyapatite for Enamel Remineralization; An In-Vitro Study of Surface Microhardness and Composition. MATERIAL AND METHODS: Ninety-six extracted human premolars with sound buccal surface were divided using a randomization computer-generating software into four groups; Group I (control) sound untreated enamel, Group II (demineralized) demineralized to create white spot lesions, Group III (biom-n-HA) demineralized and then treated with biomimetic nanohydroxyapatite cream, and Group IV (F-ACP) demineralized and then treated using Fluoride-Amorphous Calcium Phosphate varnish. Each group was divided into two subgroups; subgroup "A" evaluated for mineral content using energy dispersive x-ray spectroscopy (EDX) and for surface microhardness using the Vickers microhardness test and Subgroup "B" evaluated for white spot lesion depth using a polarized light microscope (PLM). RESULTS: The highest microhardness (VHN) was found in the (F-ACP) group (mean=428.61±54.43) and then in the (Biom-n-HA) group (mean=408.11±70.16) followed by the (Control) group (mean=402.13±53.40) with no significant difference between them and finally in the significantly different (Demineralized) group (mean=256.99±45.83). The weight percentage of Ca (30.29±1.04 and 33.44±1.07) and Ca/P ratio (1.87±0.06 and 2.03±0.05) were significantly different between Group III and Group IV respectively. PLM measurements in Group II (198.83µm), Group III (60.17µm), and Group IV (26.33µm) were significantly different. CONCLUSIONS: Both the (Biom-n-HA) cream and the (F-ACP) varnish showed promising results for enamel remineralization. The increased enamel surface microhardness was consistent with the mineral content and the changes in the birefringence.


Assuntos
Fosfatos de Cálcio , Esmalte Dentário , Durapatita , Fluoretos , Dureza , Remineralização Dentária , Humanos , Remineralização Dentária/métodos , Esmalte Dentário/efeitos dos fármacos , Durapatita/química , Fosfatos de Cálcio/farmacologia , Fluoretos/química , Cariostáticos/farmacologia , Desmineralização do Dente , Espectrometria por Raios X , Dente Pré-Molar , Microscopia de Polarização , Técnicas In Vitro , Materiais Biomiméticos/química , Fluoretos Tópicos , Propriedades de Superfície
9.
Sensors (Basel) ; 24(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38475128

RESUMO

Our work uses a polarization matrix formalism to analyze and algorithmically represent optical anisotropy by open dehydration of blood plasma films. Analytical relations for Jones matrix reconstruction of optical birefringence maps of protein crystal networks of dehydrated biofluid films are found. A technique for 3D step-by-step measurement of the distributions of the elements of the Jones matrix or Jones matrix images (JMI) of the optically birefringent structure of blood plasma films (BPF) has been created. Correlation between JMI maps and corresponding birefringence images of dehydrated BPF and saliva films (SF) obtained from donors and prostate cancer patients was determined. Within the framework of statistical analysis of layer-by-layer optical birefringence maps, the parameters most sensitive to pathological changes in the structure of dehydrated films were found to be the central statistical moments of the 1st to 4th orders. We physically substantiated and experimentally determined the sensitivity of the method of 3D polarization scanning technique of BPF and SF preparations in the diagnosis of endometriosis of uterine tissue.


Assuntos
Dispositivos Ópticos , Feminino , Humanos , Anisotropia , Microscopia de Polarização/métodos , Birrefringência , Proteínas
10.
J Biomed Opt ; 29(1): 016008, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38269081

RESUMO

Significance: The molecular mechanisms driving the progression from nonalcoholic fatty liver (NAFL) to fibrosing steatohepatitis (NASH) are insufficiently understood. Techniques enabling the characterization of different lipid species with both chemical and spatial information can provide valuable insights into their contributions to the disease progression. Aim: We extend the utility of stimulated Raman scattering (SRS) microscopy to characterize and quantify lipid species in liver tissue sections from patients with NAFL and NASH. Approach: We applied a dual-band hyperspectral SRS microscopy system for imaging tissue sections in both the C-H stretching and fingerprint regions. The same sections were imaged with polarization microscopy for detecting birefringent liquid crystals in the tissues. Results: Our imaging and analysis pipeline provides accurate classification and quantification of free cholesterol, saturated cholesteryl esters (CEs), unsaturated CE, and triglycerides in liver tissue sections. The subcellular resolution enables investigations of the heterogeneous distribution of saturated CE, which has been under-examined in previous studies. We also discovered that the birefringent crystals, previously found to be associated with NASH development, are predominantly composed of saturated CE. Conclusions: Our method allows for a detailed characterization of lipid composition in human liver tissues and enables further investigation into the potential mechanism of NASH progression.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Microscopia Óptica não Linear , Microscopia de Polarização , Lipídeos
11.
J Biomed Opt ; 29(5): 052917, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38223746

RESUMO

Significance: Breast cancer ranks second in the world in terms of the number of women diagnosed. Effective methods for its early-stage detection are critical for facilitating timely intervention and lowering the mortality rate. Aim: Polarimetry provides much useful information on the structural properties of breast cancer tissue samples and is a valuable diagnostic tool. The present study classifies human breast tissue samples as healthy or cancerous utilizing a surface-illuminated backscatter polarization imaging technique. Approach: The viability of the proposed approach is demonstrated using 95 breast tissue samples, including 35 healthy samples, 20 benign cancer samples, 20 grade-2 malignant samples, and 20 grade-3 malignant samples. Results: The observation results reveal that element m23 in the Mueller matrix of the healthy samples has a deeper color and greater intensity than that in the breast cancer samples. Conversely, element m32 shows a lighter color and reduced intensity. Finally, element m44 has a darker color in the healthy samples than in the cancer samples. The analysis of variance test results and frequency distribution histograms confirm that elements m23, m32, and m44 provide an effective means of detecting and classifying human breast tissue samples. Conclusions: Overall, the results indicate that surface-illuminated backscatter polarization imaging has significant potential as an assistive tool for breast cancer diagnosis and classification.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Análise Espectral/métodos , Refração Ocular , Microscopia de Polarização/métodos
12.
Acta Biomater ; 173: 135-147, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37967694

RESUMO

Collagen is the main load-bearing component of the peripapillary sclera (PPS) and lamina cribrosa (LC) in the eye. Whilst it has been shown that uncrimping and recruitment of the PPS and LC collagen fibers underlies the macro-scale nonlinear stiffening of both tissues with increased intraocular pressure (IOP), the uncrimping and recruitment as a function of local stretch have not been directly measured. This knowledge is crucial to understanding their functions in bearing loads and maintaining tissue integrity. In this project we measured local stretch-induced collagen fiber bundle uncrimping and recruitment curves of the PPS and LC. Thin coronal samples of PPS and LC of sheep eyes were mounted and stretched biaxially quasi-statically using a custom system. At each step, we imaged the PPS and LC with instant polarized light microscopy and quantified pixel-level (1.5 µm/pixel) collagen fiber orientations. We used digital image correlation to measure the local stretch and quantified collagen crimp by the circular standard deviation of fiber orientations, or waviness. Local stretch-recruitment curves of PPS and LC approximated sigmoid functions. PPS recruited more fibers than the LC at the low levels of stretch. At 10% stretch the curves crossed with 75% bundles recruited. The PPS had higher uncrimping rate and waviness remaining after recruitment than the LC: 0.9º vs. 0.6º and 3.1º vs. 2.7º. Altogether our findings support describing fiber recruitment of both PPS and LC with sigmoid curves, with the PPS recruiting faster and at lower stretch than the LC, consistent with a stiffer tissue. STATEMENT OF SIGNIFICANCE: Peripapillary sclera (PPS) and lamina cribrosa (LC) collagen recruitment behaviors are central to the nonlinear mechanical behavior of the posterior pole of the eye. How PPS and LC collagen fibers recruit under stretch is crucial to develop constitutive models of the tissues but remains unclear. We used image-based stretch testing to characterize PPS and LC collagen fiber bundle recruitment under local stretch. We found that fiber-level stretch-recruitment curves of PPS and LC approximated sigmoid functions. PPS recruited more fibers at a low stretch, but at 10% bundle stretch the two curves crossed with 75% bundles recruited. We also found that PPS and LC fibers had different uncrimping rates and non-zero waviness's when recruited.


Assuntos
Colágeno , Glaucoma , Animais , Ovinos , Esclera , Matriz Extracelular , Microscopia de Polarização , Fenômenos Biomecânicos
13.
J Biophotonics ; 17(2): e202300236, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37789505

RESUMO

Many optical techniques have been used in various diagnostics and biomedical applications since a decade and polarization imaging is one of the non-invasive and label free optical technique to investigate biological samples making it an important tool in diagnostics, biomedical applications. We report a multispectral polarization-based imaging of oral tissue by utilizing a polarization microscope system with a broadband-light source. Experiments were performed on oral tissue samples and multispectral Stokes mapping was done by recording a set of intensity images. Polarization-based parameters like degree of polarization, angle of fast axis, retardation and linear birefringence have been retrieved. The statistical moments of these polarization components have also been reported at multiples wavelengths. The polarimetric properties of oral tissue at different stages of cancer have been analyzed and significant changes from normal to pre-cancerous lesions to the cancerous are observed in linear birefringence quantification as (1.7 ± 0.1) × 10-3 , (2.5 ± 0.2) × 10-3 and (3.3 ± 0.2) × 10-3 respectively.


Assuntos
Diagnóstico por Imagem , Humanos , Microscopia de Polarização/métodos , Birrefringência , Análise Espectral
14.
J Biomed Opt ; 28(12): 125003, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38094709

RESUMO

Significance: Articular cartilage exhibits a zonal architecture, comprising three distinct zones: superficial, middle, and deep. Collagen fibers, being the main solid constituent of articular cartilage, exhibit unique angular and size distribution in articular cartilage zones. There is a gap in knowledge on how the unique properties of collagen fibers across articular cartilage zones affect the scattering properties of the tissue. Aim: This study hypothesizes that the structural properties of articular cartilage zones affect its scattering parameters. We provide scattering coefficient and scattering anisotropy factor of articular cartilage zones in the spectral band of 400 to 1400 nm. We enumerate the differences and similarities of the scattering properties of articular cartilage zones and provide reasoning for these observations. Approach: We utilized collimated transmittance and integrating sphere measurements to estimate the scattering coefficients of bovine articular cartilage zones and bulk tissue. We used the relationship between the scattering coefficients to estimate the scattering anisotropy factor. Polarized light microscopy was applied to estimate the depth-wise angular distribution of collagen fibers in bovine articular cartilage. Results: We report that the Rayleigh scatterers contribution to the scattering coefficients, the intensity of the light scattered by the Rayleigh and Mie scatterers, and the angular distribution of collagen fibers across tissue depth are the key parameters that affect the scattering properties of articular cartilage zones and bulk tissue. Our results indicate that in the short visible region, the superficial and middle zones of articular cartilage affect the scattering properties of the tissue, whereas in the far visible and near-infrared regions, the articular cartilage deep zone determines articular cartilage scattering properties. Conclusion: This study provides scattering properties of articular cartilage zones. Such findings support future research to utilize optical simulation to estimate the penetration depth, depth-origin, and pathlength of light in articular cartilage for optical diagnosis of the tissue.


Assuntos
Cartilagem Articular , Colágeno , Animais , Bovinos , Colágeno/química , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/química , Matriz Extracelular/química , Microscopia de Polarização , Anisotropia
15.
Exp Eye Res ; 237: 109701, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37898229

RESUMO

The collagen fibers of the corneoscleral shell play a central role in the eye mechanical behavior. Although it is well-known that these fibers form a complex three-dimensional interwoven structure, biomechanical and microstructural studies often assume that the fibers are aligned in-plane with the tissues. This is convenient as it removes the out-of-plane components and allows focusing on the 2D maps of in-plane fiber organization that are often quite complex. The simplification, however, risks missing potentially important aspects of the tissue architecture and mechanics. In the cornea, for instance, fibers with high in-depth inclination have been shown to be mechanically important. Outside the cornea, the in-depth fiber orientations have not been characterized, preventing a deeper understanding of their potential roles. Our goal was to characterize in-depth collagen fiber organization over the whole corneoscleral shell. Seven sheep whole-globe axial sections from eyes fixed at an IOP of 50 mmHg were imaged using polarized light microscopy to measure collagen fiber orientations and density. In-depth fiber orientation distributions and anisotropy (degree of fiber alignment) accounting for fiber density were quantified over the whole sclera and in 15 regions: central cornea, peripheral cornea, limbus, anterior equator, equator, posterior equator, posterior sclera and peripapillary sclera on both nasal and temporal sides. Orientation distributions were fitted using a combination of a uniform distribution and a sum of π-periodic von Mises distributions, each with three parameters: primary orientation µ, fiber concentration factor k, and weighting factor a. To study the features of fibers that are not in-plane, i.e., fiber inclination, we quantified the percentage of inclined fibers and the range of inclination angles (half width at half maximum of inclination angle distribution). Our measurements showed that the fibers were not uniformly in-plane but exhibited instead a wide range of in-depth orientations, with fibers significantly more aligned in-plane in the anterior parts of the globe. We found that fitting the orientation distributions required between one and three π-periodic von Mises distributions with different primary orientations and fiber concentration factors. Regions of the posterior globe, particularly on the temporal side, had a larger percentage of inclined fibers and a larger range of inclination angles than anterior and equatorial regions. Variations of orientation distributions and anisotropies may imply varying out-of-plane tissue mechanical properties around the eye globe. Out-of-plane fibers could indicate fiber interweaving, not necessarily long, inclined fibers. Effects of small-scale fiber undulations, or crimp, were minimized by using tissues from eyes at high IOPs. These fiber features also play a role in tissue stiffness and stability and are therefore also important experimental information.


Assuntos
Colágeno , Córnea , Animais , Ovinos , Colágeno/química , Matriz Extracelular , Esclera , Microscopia de Polarização , Fenômenos Biomecânicos
16.
J Biomed Opt ; 28(10): 102909, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37786544

RESUMO

Significance: For microscopic polarization imaging of tissue slices, two types of samples are often prepared: one unstained tissue section for polarization imaging to avoid possible influence from staining dyes quantitatively and one hematoxylin-eosin (H&E) stained adjacent tissue section for histological diagnosis and structural feature identification. However, this sample preparation strategy requires high-quality adjacent tissue sections, and labeling the structural features on unstained tissue sections is impossible. With the fast development of data driven-based polarimetric analysis, which requires a large amount of pixel labeled images, a possible method is to directly use H&E stained slices, which are standard samples archived in clinical hospitals for polarization measurement. Aim: We aim to study the influence of hematoxylin and eosin staining on the linear birefringence measurement of fibrous tissue structures. Approach: We examine the linear birefringence properties of four pieces of adjacent bone tissue slices with abundant collagen fibers that are unstained, H&E stained, hematoxylin (H) stained, and eosin (E) stained. After obtaining the spatial maps of linear retardance values for the four tissue samples, we carry out a comparative study using a frequency distribution histogram and similarity analysis based on the Bhattacharyya coefficient to investigate how H&E staining affects the linear birefringence measurement of bone tissues. Results: Linear retardance increased after H&E, H, or E staining (41.7%, 40.8%, and 72.5% increase, respectively). However, there is no significant change in the imaging contrast of linear retardance in bone tissues. Conclusions: The linear retardance values induced by birefringent collagen fibers can be enhanced after H&E, H, or E staining. However, the structural imaging contrasts based on linear retardance did not change significantly or the staining did not generate linear birefringence on the sample area without collagen. Therefore, it can be acceptable to prepare H&E stained slices for clinical applications of polarimetry based on such a mapping relationship.


Assuntos
Colágeno , Hematoxilina , Amarelo de Eosina-(YS) , Microscopia de Polarização/métodos , Birrefringência , Coloração e Rotulagem
17.
Sci Rep ; 13(1): 16596, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37789192

RESUMO

Terahertz (THz) technology offers a variety of applications in label-free medical diagnosis and therapy, majority of which rely on the effective medium theory that assumes biological tissues to be optically isotropic and homogeneous at the scale posed by the THz wavelengths. Meanwhile, most recent research discovered mesoscale ([Formula: see text]) heterogeneities of tissues; [Formula: see text] is a wavelength. This posed a problem of studying the related scattering and polarization effects of THz-wave-tissue interactions, while there is still a lack of appropriate tools and instruments for such studies. To address this challenge, in this paper, quantitative polarization-sensitive reflection-mode THz solid immersion (SI) microscope is developed, that comprises a silicon hemisphere-based SI lens, metal-wire-grid polarizer and analyzer, a continuous-wave 0.6 THz ([Formula: see text] µm) backward-wave oscillator (BWO), and a Golay detector. It makes possible the study of local polarization-dependent THz response of mesoscale tissue elements with the resolution as high as [Formula: see text]. It is applied to retrieve the refractive index distributions over the freshly-excised rat brain for the two orthogonal linear polarizations of the THz beam, aimed at uncovering the THz birefringence (structural optical anisotropy) of tissues. The most pronounced birefringence is observed for the Corpus callosum, formed by well-oriented and densely-packed axons bridging the cerebral hemispheres. The observed results are verified by the THz pulsed spectroscopy of the porcine brain, which confirms higher refractive index of the Corpus callosum when the THz beam is polarized along axons. Our findings highlight a potential of the quantitative polarization THz microscopy in biophotonics and medical imaging.


Assuntos
Imersão , Refratometria , Animais , Suínos , Birrefringência , Microscopia de Polarização , Encéfalo/diagnóstico por imagem
18.
Sci Rep ; 13(1): 13424, 2023 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-37591987

RESUMO

The peri-tumoural stroma has been explored as a useful source of prognostic information in colorectal cancer. Using Mueller matrix (MM) polarized light microscopy for quantification of unstained histology slides, the current study assesses the prognostic potential of polarimetric characteristics of peri-tumoural collagenous stroma architecture in 38 human stage III colorectal cancer (CRC) patient samples. Specifically, Mueller matrix transformation and polar decomposition parameters were tested for association with 5-year patient local recurrence outcomes. The results show that some of these polarimetric parameters were significantly different (p value < 0.05) for the recurrence versus the no-recurrence patient cohorts (Mann-Whitney U test). MM parameters may thus be prognostically valuable towards improving clinical management/treatment stratification in CRC patients.


Assuntos
Neoplasias Colorretais , Humanos , Técnicas Histológicas , Microscopia de Polarização , Pacientes , Refração Ocular
19.
Joint Bone Spine ; 90(6): 105611, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37442334

RESUMO

OBJECTIVES: We studied the performance of Raman spectroscopy integrated with polarized light microscopy (iRPolM) as a next-generation technique for synovial fluid analysis in gout. METHODS: This is a prospective study, including consecutive synovial fluid samples drawn from any peripheral swollen joint. Diagnostic accuracy was compared to the 2015 ACR/EULAR Gout classification criteria as a reference test and to polarized light microscopy (PLM) analysis by a rheumatologist. Synovial fluid was analysed with iRPolM after unblinding the PLM results. RESULTS: Two hundred unselected consecutive patient samples were included in this study. Validation against clinical criteria: 67 patients were classified as gout according to 2015 ACR/EULAR classification criteria. Compared to the 2015 ACR/EULAR gout classification criteria, iRPolM had a sensitivity of 77.6% (95% CI: 65.8-86.9), specificity of 97.7% (95% CI: 93.5-99.5), positive predictive value (PPV) of 94.5% (95% CI: 84.9-98.2), negative predictive value (NPV) of 89.7% (95% CI: 84.7-93.1), an accuracy of 91.0% (95% CI: 86.2-94.6), a positive likelihood ratio of 34.4 (95% CI: 11.16-106.10) and a negative likelihood ratio of 0.23 (95% CI: 0.15-0.36). Validation against PLM: 55 samples were positive for MSU according to PLM. The interrater agreement between PLM and iRPolM was near perfect (к=0.90). The sensitivity of iRPolM to identify MSU in PLM-positive samples was 91.2% (95% CI: 80.7-97.1), the specificity was 97.6% (95% CI: 93.0-99.5), the PPV was 94.6% (95% CI: 85.0-98.2), NPV was 96.0% (95% CI: 91.2-98.2) and the accuracy was 95.6% (95% CI: 91.4-98.2). The positive likelihood ratio was 37.4 (95% CI: 12.20-114.71), and the negative likelihood ratio was 0.09 (95% CI: 0.04-0.21). CONCLUSION: iRPolM is a promising next-generation diagnostic tool for rheumatology by diagnosing gout with high specificity, increased objectivity, and a sensitivity comparable to PLM.


Assuntos
Artrite Gotosa , Gota , Humanos , Artrite Gotosa/diagnóstico , Microscopia de Polarização , Estudos Prospectivos , Análise Espectral Raman , Ácido Úrico/análise , Sensibilidade e Especificidade , Gota/diagnóstico
20.
Sci Rep ; 13(1): 7505, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-37160946

RESUMO

Conventional polarized light microscopy has been widely used to detect gouty crystals, but its limited sensitivity increases the risk of misidentification. In this study, a number of methods were investigated to improve the sensitivity of polarized light microscopy for the detection of monosodium urate monohydrate (MSUM) and calcium pyrophosphate dihydrate (CPPD) crystals. We found that coating glass slides with poly-L-lysine, a positively charged polymer, improved the attachment of crystals to the glass surface, resulting in clearer crystal images compared to non-coated slides. Additionally, the sensitivity of detection was further enhanced by selective dissolution, in which 40% v/v formalin phosphate buffer was employed to dissolve MSUM crystals but not CPPD while 10% ethylenediamine tetraacetic acid (EDTA) was employed to dissolved CPPD but not MSUM. The other possible interferences were dissolved in both EDTA and formalin solution. These methods were successfully applied to detect gouty crystals in biological milieu, including spiked porcine synovial fluid and inflamed rat subcutaneous air pouch tissues.


Assuntos
Gota , Animais , Ratos , Suínos , Ácido Edético , Microscopia de Polarização , Solubilidade , Gota/diagnóstico , Formaldeído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...