Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
1.
Int Ophthalmol ; 44(1): 240, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38904711

RESUMO

PURPOSE: To clarify the characteristics of intraocular lens (IOL) dislocation requiring IOL suture or intraocular scleral fixation. METHODS: This retrospective consecutive case series included 21 eyes (21 patients) who required sutured or sutureless intrascleral IOL fixation following IOL extraction owing to IOL dislocation at the outpatient clinic in the Department of Ophthalmology, Saitama Red Cross Hospital, Japan, between January and December 2019. Medical records were retrospectively reviewed for background diseases, location of the dislocated IOL (intracapsular/extracapsular), insertion of a capsular tension ring (CTR), and the period from IOL insertion to dislocation. RESULTS: We included 21 eyes of 21 patients who required IOL suture or intrascleral fixation for IOL dislocation at our clinic from January to December 2019 were included. The most common background disease was pseudoexfoliation syndrome (four cases), followed by atopic dermatitis, dysplasia/dehiscence of the zonule, post-retinal detachment surgery, high myopia, and uveitis (three cases each). At the time of dislocation, the IOLs were either intracapsular (16 cases, including 3 cases with CTR insertion) or extracapsular (5 cases). The time from IOL insertion to IOL dislocation was 13.7 ± 8.1 years (maximum: 31.3 years, minimum: 1.7 years). CONCLUSIONS: In this study, all 21 cases represented late IOL dislocations occurring after 3 months postoperatively. Among these late IOL dislocation cases, IOL dislocation occurred in a short-medium period of time, especially in those with CTR insertion and weakness/dehiscence of the zonule, with an average of 3 to 5 years postoperatively. We propose referring to these cases as intermediate-term IOL dislocation.


Assuntos
Migração do Implante de Lente Intraocular , Lentes Intraoculares , Humanos , Estudos Retrospectivos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Migração do Implante de Lente Intraocular/cirurgia , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/diagnóstico , Lentes Intraoculares/efeitos adversos , Idoso de 80 Anos ou mais , Fatores de Tempo , Acuidade Visual , Adulto , Esclera/cirurgia , Técnicas de Sutura , Seguimentos , Implante de Lente Intraocular/métodos , Implante de Lente Intraocular/efeitos adversos , Complicações Pós-Operatórias
2.
Int Ophthalmol ; 44(1): 203, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671195

RESUMO

PURPOSE: This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. METHODS: This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively. RESULTS: All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively (P = 0.37 and P = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian (P = 0.11 and P = 0.22, respectively). CONCLUSIONS: The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. TRIAL REGISTRATION: The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155).


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares Multifocais , Acuidade Visual , Humanos , Masculino , Feminino , Estudos Prospectivos , Catarata/complicações , Catarata/fisiopatologia , Pré-Escolar , Criança , Extração de Catarata/métodos , Extração de Catarata/efeitos adversos , Seguimentos , Desenho de Prótese , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/fisiopatologia , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/cirurgia , Implante de Lente Intraocular/métodos , Lactente
3.
Int Ophthalmol ; 44(1): 194, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656707

RESUMO

PURPOSE: To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS. METHODS: 94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration. RESULTS: The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001). CONCLUSION: Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.


Assuntos
Segmento Anterior do Olho , Facoemulsificação , Tomografia de Coerência Óptica , Humanos , Facoemulsificação/efeitos adversos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Idoso , Segmento Anterior do Olho/diagnóstico por imagem , Lentes Intraoculares/efeitos adversos , Pessoa de Meia-Idade , Acuidade Visual , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Implante de Lente Intraocular/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Cristalino/diagnóstico por imagem , Estudos Prospectivos
4.
J Cataract Refract Surg ; 50(6): 611-617, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350154

RESUMO

PURPOSE: To explore lens capsule pathological characteristics in intraocular lens (IOL) dislocation after cataract surgery in patients with atopic dermatitis (AD). SETTING: University hospital department of ophthalmology. DESIGN: Case series with clinicopathological correlations. METHODS: Lens capsules and surrounding tissues excised during surgery from eyes with AD (AD group) and eyes without AD (non-AD group) with IOL dislocation were histologically evaluated. Hematoxylin and eosin staining was used to assess abnormal changes in lens epithelial cells (LECs). Masson trichrome staining distinguished the fibrous metaplasia around the lens capsule into high-density and low-density fibrosis. Capsular splitting (thinning) was identified in both stained preparations. RESULTS: The IOL dislocation morphology in the AD group (10 eyes of 10 patients) included 7 cases of capsular bag dislocation (CBD) and 3 cases of dead bag syndrome (DBS), with an average duration to IOL dislocation of 11.5 ± 5.6 years. All patients in the non-AD group (12 eyes of 12 patients) had CBD, averaging 10.2 ± 5.7 years to dislocation. Abnormal LECs, low-density fibrosis, and capsular splitting were observed in 9 (90), 9 (90), and 6 (60) of the patients in the AD group compared with 6 (50), 3 (25), and 2 (18), respectively, in the non-AD group (total n [%]). CONCLUSIONS: Compared with the non-AD group, the AD group exhibited higher frequencies of morphological changes in LECs, low-density fibrosis around the lens capsule, and capsular splitting characteristics of DBS. These results suggest LEC degeneration and increased lens capsule fragility occurred in patients with AD.


Assuntos
Dermatite Atópica , Cápsula do Cristalino , Humanos , Cápsula do Cristalino/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Dermatite Atópica/complicações , Adulto , Migração do Implante de Lente Intraocular/etiologia , Idoso , Implante de Lente Intraocular , Facoemulsificação , Fibrose , Células Epiteliais/patologia , Lentes Intraoculares , Estudos Retrospectivos , Extração de Catarata
5.
Acta Ophthalmol ; 102(5): e805-e812, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38292001

RESUMO

PURPOSE: The purpose of this study was to compare the tilt and decentration of one-piece anti-vaulting haptic intraocular lenses (IOL) and three-piece C-loop haptic IOLs in paediatric eyes undergoing secondary IOL implantation into the ciliary sulcus. METHODS: Paediatric aphakic patients receiving either one-piece anti-vaulting haptic or three-piece C-loop haptic IOL implants into the ciliary sulcus were enrolled in this prospective non-randomized interventional study and followed up for 3 years. IOL decentration and tilt were measured using Scheimpflug images. Preoperative and postoperative information, including demographic data and ocular biometric parameters and complications, were collected and analysed. RESULTS: Among 123 eyes of 79 paediatric patients, there were 72 eyes (58.54%) in the anti-vaulting haptic IOL group and 51 eyes (41.46%) in the C-loop haptic group. The anti-vaulting haptic IOL group had a lower incidence of clinically significant vertical IOL decentration than the C-loop haptic IOL group (23.88% vs. 43.14%, p = 0.037). No intergroup differences were observed in vertical or horizontal tilt or in horizontal decentration (all p > 0.05). One-piece anti-vaulting haptic IOL implantation was associated with a lower risk of clinically significant vertical decentration than three-piece C-loop haptic IOL implantation (odds ratio: 0.42, p = 0.037). There was a higher incidence of IOL dislocation in the C-loop haptic IOL group (15.22% vs. 4.17%, p = 0.046). CONCLUSIONS: In paediatric aphakic eyes undergoing secondary IOL implantation into the ciliary sulcus, one-piece anti-vaulting haptic IOLs can reduce the risk of clinically significant vertical IOL decentration compared with three-piece C-loop haptic IOLs and may favour long-term IOL positional stability.


Assuntos
Corpo Ciliar , Implante de Lente Intraocular , Lentes Intraoculares , Desenho de Prótese , Acuidade Visual , Humanos , Estudos Prospectivos , Masculino , Feminino , Lentes Intraoculares/efeitos adversos , Pré-Escolar , Seguimentos , Corpo Ciliar/cirurgia , Implante de Lente Intraocular/métodos , Criança , Afacia Pós-Catarata/fisiopatologia , Afacia Pós-Catarata/cirurgia , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/prevenção & controle , Migração do Implante de Lente Intraocular/fisiopatologia , Lactente , Refração Ocular/fisiologia , Complicações Pós-Operatórias/epidemiologia , Fatores de Tempo
6.
Am J Ophthalmol ; 242: 88-95, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35594914

RESUMO

PURPOSE: To identify risk factors associated with intraocular lens (IOL) decentration after uneventful phacoemulsification with IOL implantation. DESIGN: A prospective cohort study. METHODS: All patients underwent a general ophthalmologic examination. One month postoperatively, the magnitude and orientation of IOL decentration relative to the visual axis center were assessed using an OPD-Scan III aberrometer, and the vertical and horizontal decentration values were determined. Univariate and multivariate linear regression analyses were performed to evaluate the association between the IOL decentration and ocular biometric parameters. RESULTS: In total, 143 eyes of 143 patients were enrolled. The mean decentration magnitude was 0.27 ± 0.15 mm, and the decentration axis appeared at any orientation, with no orientation tendency. The horizontal and vertical decentration were -0.02 ± 0.22 mm and 0.01 ± 0.22 mm, respectively. Multivariate regression analysis showed that the white-to-white distance and the magnitude of angle α were positively associated with the decentration magnitude (P < .001, adj. R2 = 0.121), the horizontal angle κ and horizontal angle α were positively associated with the horizontal decentration (P < .001, adj. R2 = 0.209), and the anterior chamber depth and vertical angle κ were positively associated with the vertical decentration (P < .001, adj. R2 = 0.152). CONCLUSIONS: The IOL decentration magnitude was greater in patients with a larger white-to-white distance and a larger angle α, the horizontal decentration was greater in patients with a larger horizontal angle κ and a larger horizontal angle α, and the vertical decentration was greater in patients with a deeper anterior chamber depth and a larger vertical angle κ. In these patients, premium IOLs should be implanted cautiously.


Assuntos
Migração do Implante de Lente Intraocular , Catarata , Lentes Intraoculares , Facoemulsificação , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Catarata/complicações , Humanos , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares/efeitos adversos , Facoemulsificação/efeitos adversos , Estudos Prospectivos , Refração Ocular , Fatores de Risco , Acuidade Visual
7.
Retina ; 41(10): 2035-2040, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34543241

RESUMO

PURPOSE: To assess the incidence of cystoid macular edema (CME) associated with 4-point Gore-Tex suture intraocular lens (IOL) scleral fixation, before and after institution of routine intravitreal triamcinolone acetonide prophylaxis and long-term topical nonsteroidal anti-inflammatory drug usage. METHODS: Consecutive patients were included after IOL implantation with concurrent pars plana vitrectomy for spontaneous IOL dislocation due to pseudoexfoliation syndrome. We compared short-term prophylactic nonsteroidal anti-inflammatory drugs only (Group A) to prophylactic intravitreal triamcinolone acetonide and long-term nonsteroidal anti-inflammatory drugs (Group B). RESULTS: Twenty-six eyes of 26 patients with pseudoexfoliation syndrome and spontaneous IOL dislocation were studied. Mean logMAR visual acuity improved from 1.27 ± 0.80 (20/375 Snellen equivalent) preoperatively to 0.46 ± 0.39 (Snellen 20/43) postoperatively (P < 0.001). Visual outcomes were similar for Groups A and B. In Group A, 10/16 eyes had CME, 4/16 had chronic CME longer than 6 months, and 1 longer than 12 months. In Group B, 1/10 had CME (which was both chronic and refractory). CONCLUSION: In eyes with pseudoexfoliation syndrome and spontaneous IOL dislocation, 4-point Gore-Tex suture IOL ab externo fixation yielded good visual outcomes, although CME was observed more than reported elsewhere. Prophylactic intravitreal triamcinolone acetonide and long-term nonsteroidal anti-inflammatory drugs seem to reduce the risk of postoperative CME.


Assuntos
Implante de Lente Intraocular/efeitos adversos , Edema Macular/etiologia , Esclera/cirurgia , Idoso , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/cirurgia , Síndrome de Exfoliação/etiologia , Feminino , Humanos , Incidência , Edema Macular/epidemiologia , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Estudos Retrospectivos , Técnicas de Sutura , Suturas , Acuidade Visual/fisiologia , Vitrectomia
8.
Digit J Ophthalmol ; 26(2): 7-16, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33867876

RESUMO

We report a case of late breakage of a 9-0 polypropylene transscleral suture used for fixation of a dislocated capsular bag-intraocular lens-modified capsular tension ring complex in a 52-year-old woman with Marfan syndrome. Breakage occurred despite use of a cow-hitch technique for external and internal fixation. We believe breakage was caused by the suture chafing on the sharp edges of the modified capsular tension ring eyelet. Cross-sectional analysis of Malyugin-modified capsular tension rings from two different manufacturers revealed a difference with respect to radius of curvature. Suturing intraocular implants with relatively sharp edges may cause suture breakage; further studies are needed to identify the critical parameters for the surface quality of sutured intraocular implants.


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Lentes Intraoculares/efeitos adversos , Polipropilenos , Complicações Pós-Operatórias , Esclera/cirurgia , Técnicas de Sutura/efeitos adversos , Suturas/efeitos adversos , Migração do Implante de Lente Intraocular/cirurgia , Falha de Equipamento , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Reoperação/métodos , Fatores de Tempo
9.
Ocul Immunol Inflamm ; 29(7-8): 1553-1558, 2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-32643989

RESUMO

Purpose: To describe practical approaches to the management of subluxed or dislocated intraocular lenses (IOL) in patients with uveitis.Patients and methods: Retrospective case series from a specialist uveitis clinicResults: Fifteen IOLs in 13 patients were subluxed inferiorly (12) or dislocated into anterior chamber (2) or vitreous (1) at a mean delay of 12 years after cataract surgery. Six eyes required vitrectomy and seven IOL explantation. A dislocated IOL was repositioned by scleral fixation in one, and a new IOL was implanted in three (two scleral-sutured, one iris-claw). Eight were observed without surgery and 7 were left functionally aphakic (4 corrected with contact lens). The mean final best-corrected visual acuity was 0.6 LogMAR.Conclusions: There are several management choices for IOL dislocation which should take into account the degree of uveitis, patient age and expectations. We present a pragmatic approach: surgery can often be avoided in this high-risk group.


Assuntos
Migração do Implante de Lente Intraocular/cirurgia , Complicações Pós-Operatórias/cirurgia , Uveíte/complicações , Adulto , Idoso , Migração do Implante de Lente Intraocular/etiologia , Remoção de Dispositivo , Feminino , Seguimentos , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Acuidade Visual/fisiologia , Adulto Jovem
10.
Am J Ophthalmol ; 221: 273-278, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32777376

RESUMO

OBJECTIVE: To report clinical features and visual outcomes following eyelet fractures of scleral-sutured enVista MX60 (Bausch + Lomb) intraocular lenses (IOL). DESIGN: Retrospective, multi-center, multi-surgeon, observational case series. METHODS: Study Population: Patients with scleral-sutured enVista MX60 IOLs that experienced either an intraoperative or post-operative eyelet fracture associated with dislocation or subluxation. PROCEDURES: All records were reviewed for patients with a dislocated or subluxed scleral-sutured enVista MX60 IOL. Clinical features and outcomes were gathered. Main Outcome Measures: Clinical setting, surgical technique, complications, and visual acuity. RESULTS: A total of 25 scleral-sutured enVista MX60 IOLs displacements secondary to eyelet fractures in 23 eyes of 23 patients were included. There were 20 IOLs that sustained a postoperative fracture and 5 IOLs that sustained an intraoperative fracture. Of the postoperative fractures, 7 were dislocated and 13 were subluxed. Gore-Tex was the suture of choice for 19 of the postoperative fractures and all 5 of the intraoperative fractures, and Prolene was used for 1 postoperative fracture. The mean time until postoperative fracture was 96 ± 125 days, and the median time was 61 (IQR 48-144) days. Of the postoperative fractures, new MX60s were sutured in 10 patients, and 2 of them experienced repeat displacements due to a new eyelet fracture. In the intraoperative fracture group, new MX60s were sutured in 4 patients and an Akreos AO60 lens was placed in the 5th patient. The mean preoperative best-corrected logMAR visual acuity for all patients improved from 1.2 ± 0.8 (20/317 Snellen equivalent) to 0.5 ± 0.5 (20/63 Snellen equivalent) at most recent follow-up after lens replacement. CONCLUSIONS: Scleral-sutured MX60 intraocular lenses can experience intraoperative or postoperative eyelet fractures, resulting in lens subluxation or dislocation. Surgeons should be aware of this complication when evaluating secondary intraocular lens options.


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Complicações Intraoperatórias , Implante de Lente Intraocular/métodos , Complicações Pós-Operatórias , Falha de Prótese/etiologia , Esclera/cirurgia , Técnicas de Sutura , Adulto , Idoso , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Retrospectivos , Fatores de Tempo , Acuidade Visual/fisiologia , Vitrectomia
11.
J Fr Ophtalmol ; 43(10): 1062-1068, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32811657

RESUMO

PURPOSE: To evaluate the predisposing factors, management and visual prognosis of intraocular Lens (IOL) dislocation into the posterior segment. METHODS: The cases of posterior IOL dislocation from January 2012 to May 2017 at 2 centers were reviewed. Only eyes with dislocations requiring IOL explantation or repositioning were included. Predisposing factors, interval between cataract surgery and IOL dislocation, circumstances of onset, management, and postoperative complications are reported. RESULTS: 72 eyes of 72 patients were included. The mean age was 67.6 years. 47 patients (68%) were men. The mean time interval from cataract surgery to IOL dislocation was significantly shorter in the out-of-the bag group than the in-the-bag IOL dislocation group (3.8 months vs 132 months, P=0.002). Predisposing factors for out-of-the-bag IOL dislocation were mainly capsular rupture and/or zonular dehiscence (83%) after complicated cataract surgery. The predisposing factors for in-the-bag IOL dislocation were high myopia (40%), pseudoexfoliation syndrome (40%), previous vitrectomy (38%), or Marfan syndrome (3%) with uneventful cataract surgery. The type of luxated implant was mainly a 3-piece foldable IOL (50%), followed by foldable one-piece IOL (28%) and a rigid one-piece IOL (17%). Most cases of posterior chamber IOL dislocation occurred spontaneously (80%) without a trigger event. Management consisted of a posterior approach in 24 cases (33%) or an anterior approach in 48 cases (67%), associated with IOL repositioning in 20 eyes (28%), and IOL replacement in 34 eyes (47%). Finally, 18 eyes (25%) were left aphakic. Postoperative complications occurred in 7 cases (9.7%). CONCLUSIONS: Predisposing factors and time from cataract surgery to IOL dislocation were different for out-of-the bag versus in-the-bag IOL dislocation. Management of IOL dislocation varied considerably, depending on surgeon preference and experience. Surgery for IOL dislocation significantly improved best corrected visual acuity and was associated with a low complication rate.


Assuntos
Migração do Implante de Lente Intraocular , Remoção de Dispositivo , Falha de Prótese/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/epidemiologia , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/cirurgia , Remoção de Dispositivo/métodos , Remoção de Dispositivo/estatística & dados numéricos , Síndrome de Exfoliação/complicações , Síndrome de Exfoliação/diagnóstico , Síndrome de Exfoliação/epidemiologia , Síndrome de Exfoliação/cirurgia , Feminino , Humanos , Cápsula do Cristalino/patologia , Cápsula do Cristalino/cirurgia , Implante de Lente Intraocular/efeitos adversos , Implante de Lente Intraocular/estatística & dados numéricos , Subluxação do Cristalino/diagnóstico , Subluxação do Cristalino/epidemiologia , Subluxação do Cristalino/etiologia , Subluxação do Cristalino/cirurgia , Lentes Intraoculares/efeitos adversos , Masculino , Pessoa de Meia-Idade , Miopia/complicações , Miopia/diagnóstico , Miopia/epidemiologia , Miopia/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Prognóstico , Reoperação/métodos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Vitrectomia/efeitos adversos , Vitrectomia/métodos , Vitrectomia/estatística & dados numéricos
12.
J Cataract Refract Surg ; 46(2): 320-324, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32126051

RESUMO

A 45-year-old man was originally referred for management of spontaneous subluxation of the inferior haptic of a 3-piece intraocular lens (IOL) into the anterior chamber of the right eye (). He had a significant past ocular history of laser-assisted laser in situ keratomileusis (LASIK) in both eyes, pars plana vitrectomy/scleral buckle for retinal detachment repair in the right eye, and pseudophakia in both eyes. The corrected distance visual acuity was 20/200 in the right eye and 20/20 in the left eye. Of note, he had severe iridodonesis, a 2+ pigmented cell in the anterior chamber without significant pseudophacodonesis and the posterior capsule was intact with striae. The referring physician attempted a refixation surgery that failed, and the patient was ultimately left aphakic.Next, a secondary 3-piece posterior chamber (PC) IOL (CT Lucia 602, Carl Zeiss Meditec AG) was fixated with the Yamane flanged intrascleral haptic fixation technique (ISHF). A surgical peripheral iridotomy (PI) was made with the vitrector to avoid pupillary capture postoperatively.On postoperative day 1 the patient had a well-centered PC IOL and uncorrected distance visual acuity (UCVA) of 20/30. However, on postoperative day 14 the patient complained of decreased vision as the UCVA dropped to 20/100 and pupillary capture of the optic was noted. In addition, there was a 3+ pigmented cell in the anterior chamber, pigment dusting on the anterior surface of the PC IOL, and an intraocular pressure (IOP) of 32 mm Hg ().What additional testing would you consider? How would you manage this patient's problem?


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares Multifocais , Transtornos da Visão/etiologia , Transtornos da Visão/reabilitação , Humanos , Iridectomia , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia
13.
Eur J Ophthalmol ; 30(5): NP79-NP81, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30897947

RESUMO

PURPOSE: Fracture of a three-piece polyimide-elastimide intraocular lens at the optic-haptic junction following blunt trauma is a possible complication after cataract surgery. We report a case of an isolated posterior chamber intraocular lens fracture caused by direct ocular blunt trauma. CASE: A 51-year-old patient underwent blunt orbital trauma caused by a raw chicken egg that was thrown at him, as he was walking. The posterior chamber intraocular lens was found in the anterior chamber, with a broken optic-haptic junction. The intraocular lens was exchanged, followed by iris fixation and pupilloplasty, with satisfactory postoperative anatomical and optical outcomes. DISCUSSION: The three-piece polyimide-elastimide intraocular lens was fractured at the optic-haptic junction. Although the fractured intraocular lens surface had a regular appearance, it has been previously reported that the polyimide haptic's durability is probably inferior to that of polymethylmethacrylate. Therefore, it is highly susceptible to shear stress induced by a blunt trauma. CONCLUSION: To our knowledge, this is an uncommon report of an implanted posterior chamber polyimide-elastimide intraocular lens fracture following blunt orbital trauma. Intraocular lens exchange and fixation had successful optical and anatomical results.


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Traumatismos Oculares/etiologia , Lentes Intraoculares , Falha de Prótese/etiologia , Ferimentos não Penetrantes/etiologia , Câmara Anterior/cirurgia , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/cirurgia , Humanos , Implante de Lente Intraocular , Edema Macular/diagnóstico por imagem , Edema Macular/etiologia , Edema Macular/cirurgia , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Reoperação , Resinas Sintéticas , Tomografia de Coerência Óptica
14.
Eur J Ophthalmol ; 30(3): 538-542, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-30789069

RESUMO

PURPOSE: The aim of this article is to describe the safety and efficacy of trans-iris suture fixation for the management of late dislocation of in-the-capsular-bag intraocular lenses following uncomplicated cataract surgery. PATIENTS AND METHODS: Eleven eyes of 11 patients with late in-the-capsular-bag intraocular lens dislocation following uneventful phacoemulsification cataract surgery were recruited in the study. The dislocated intraocular lens-capsular bag complex was sutured to the iris at two points 180° apart using 9-0 polypropylene sutures on long needles. RESULTS: Mean patient age was 67 ± 6 years. Seven eyes had pseudoexfoliation syndrome, one eye had Marfan syndrome, and another eye had a traumatic cataract; no risk factor was identified for intraocular lens dislocation in two eyes. A capsular tension ring had been implanted during cataract surgery in four eyes. In six eyes, the posterior chamber intraocular lenses were one-piece foldable while the remaining were three-piece intraocular lenses. Compared to the preoperative value, corrected distance visual acuity was significantly improved postoperatively (p < 0.005). Intraoperative hyphema occurred in two eyes. Pupil ovalization was observed in all eyes. Mean endothelial cell count decreased by 4 ± 1.7% after intraocular lens fixation. The capsular bag-intraocular lens complex was stable and well-centered in the pupillary area in all eyes at the final follow-up examination which was performed 16 ± 4 months postoperatively. CONCLUSION: Trans-iris fixation is a simple and effective procedure for management of late intraocular lenses-capsular bag complex dislocation, without major complications.


Assuntos
Migração do Implante de Lente Intraocular/cirurgia , Iris/cirurgia , Implante de Lente Intraocular/métodos , Complicações Pós-Operatórias , Técnicas de Sutura , Idoso , Migração do Implante de Lente Intraocular/etiologia , Catarata/etiologia , Síndrome de Exfoliação/complicações , Traumatismos Oculares/etiologia , Feminino , Seguimentos , Humanos , Pressão Intraocular/fisiologia , Cristalino/lesões , Masculino , Síndrome de Marfan/complicações , Pessoa de Meia-Idade , Facoemulsificação , Complicações Pós-Operatórias/cirurgia , Microscopia com Lâmpada de Fenda , Acuidade Visual/fisiologia
15.
J Cataract Refract Surg ; 45(11): 1637-1644, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31706518

RESUMO

PURPOSE: To compare intraocular lens (IOL) tilt and decentration after Nd:YAG laser posterior capsulotomy in eyes that had femtosecond laser-assisted capsulotomy versus manual capsulorhexis. SETTING: Ekol Eye Hospital, Izmir, Turkey. DESIGN: Retrospective case series. METHODS: Intraocular lens decentration and angle of tilt were measured using a Scheimpflug camera before and 1 month after Nd:YAG capsulotomy. RESULTS: Eighteen eyes had a femtosecond laser-assisted capsulotomy and 25 eyes a manual capsulorhexis. The mean age was 58.2 years ± 10.2 (SD) (range 44 to 69 years) and 60.6 ± 8.3 years (range 45 to 70 years), respectively. Before capsulotomy, the angle of tilt and decentration at both meridians did not differ significantly between the 2 groups (P > .05). After capsulotomy, the angle of tilt was significantly decreased in both groups (femtosecond: vertical 1.5 degrees and horizontal 1.2 degrees; manual: vertical 1.1 degrees and horizontal) and decentration was significantly increased (femtosecond: vertical 0.085 mm and horizontal 0.096 mm; manual: vertical 0.2 mm and horizontal 0.2 mm) at both meridians (P < .05). After capsulotomy, all tilt and decentration parameters were significantly different between the 2 groups (P < .05) except decentration on the horizontal meridian (P = .669). CONCLUSIONS: Nd:YAG posterior capsulotomy performed after femtosecond laser-assisted capsulotomy resulted in better mechanical stability of the IOL. This suggests that a femtosecond laser-created capsulotomy better maintains a proper IOL position. Although the differences were statistically significant, the tilt and decentration values were small and might not be clinically significant.


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Capsulorrexe/métodos , Capsulotomia Posterior/efeitos adversos , Adulto , Idoso , Migração do Implante de Lente Intraocular/diagnóstico , Feminino , Humanos , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Refração Ocular/fisiologia , Estudos Retrospectivos , Acuidade Visual/fisiologia
18.
J Cataract Refract Surg ; 45(4): 394-397, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30713019

RESUMO

We describe a technique for repositioning an encapsulated, posteriorly dislocated silicone plate-haptic toric intraocular lens (IOL) while preventing further dislocation into the vitreous cavity. Sutures of 10-0 polypropylene were used to ensure safe retrieval of the dislocated IOL. An anterior vitrectomy was then performed to remove the contracted capsular bag around the IOL. The IOL fixation hole was temporarily externalized to allow quick and secure IOL fixation, eliminating the risk for losing the slippery silicone IOL into the vitreous cavity. Using this technique, the IOL was successfully placed in the proper position and resulted in good vision for the patient while avoiding the trauma of lens exchange.


Assuntos
Migração do Implante de Lente Intraocular/cirurgia , Polipropilenos , Elastômeros de Silicone , Técnicas de Sutura , Suturas , Vitrectomia , Idoso , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Humanos , Masculino , Reoperação , Microscopia com Lâmpada de Fenda , Acuidade Visual/fisiologia
19.
Br J Ophthalmol ; 103(2): 186-190, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29666120

RESUMO

BACKGROUND: To evaluate rotation and its influencing factors of an aspheric one-piece hydrophobic acrylic intraocular lens (IOL) Vivinex XY1 during 6 months after operation. METHODS: In this institutional trial, 122 eyes of 66 patients were implanted with a non-toric aspheric IOL Vivinex XY1 (Hoya Corporation, Tokyo, Japan). IOL alignment was assessed at the end of surgery, 1 hour, 1 week, 1 month and 6 months after implantation. Confounding factors such as axial length, presence of anterior fibrosis and randomised implantation in four different intended axes (0°, 45°, 90°, 135°) were evaluated. Decentration and tilt were measured using a Purkinje metre. RESULTS: Assessment of rotational stability was possible for 103 of 122 implanted IOLs 6 months after eye surgery. The median absolute rotation was 1.1° (range: 0°-5°). Rotation was significantly increased within the first hour after operation compared with later time-points (p<0.001). No correlation was found with axial length and rotation (Spearman's r=0.048, p=0.63). No significant difference was observed regarding different implantation axes (p=0.75). Rotation was not influenced by the presence of anterior fibrosis (p=0.98). CONCLUSION: Assessing the true IOL position at the end of surgery is crucial for the evaluation of rotational stability of IOLs. No IOL rotation exceeding 5° could be detected 6 months after surgery.


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Lentes Intraoculares , Facoemulsificação , Rotação , Idoso , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Feminino , Seguimentos , Humanos , Interações Hidrofóbicas e Hidrofílicas , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
20.
Graefes Arch Clin Exp Ophthalmol ; 256(12): 2361-2367, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30276468

RESUMO

BACKGROUND: To evaluate long-term intraocular lens (IOL) decentration and tilt in eyes with pseudoexfoliation syndrome (PES) following cataract surgery using Visante anterior segment OCT and iTrace Visual Function Analyzer. METHODS: Sixty-four eyes following cataract surgery from 2009 to 2012 were included, 34 eyes had PES and 30 eyes did not show PES. A standard phacoemulsification procedure followed by IOL implantation was performed and patients were followed 4-6 years after surgery (mean = 69 months). Best-corrected visual acuity (BCVA), capsulorhexis size, and intraocular pressure (IOP) were measured. IOL decentration and IOL tilt were evaluated using Visante Omni anterior segment OCT (Carl Zeiss Jena GmBH, Germany). The iTrace VFA (Visual Function Analyzer, Hoya surgical optics) was used to measure corneal, internal, and total optical aberrations. RESULTS: Measurements with iTrace showed that horizontal coma was significantly different between PES and control eyes (p = 0.037). Horizontal as well as vertical tilt showed a significant difference between PES and control eyes (p = 0.035 and p = 0.039). Tilt correlated with capsulorhexis size in PES patients (p = 0.011). This indicates a forward tilt of the superior edge of the IOL in eyes with PES. CONCLUSIONS: Patients affected by PES seem to have a higher risk for long-term complications and changes in visual perception due to IOL tilt and decentration after cataract surgery.


Assuntos
Migração do Implante de Lente Intraocular/diagnóstico , Extração de Catarata/efeitos adversos , Síndrome de Exfoliação/cirurgia , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias , Refração Ocular/fisiologia , Medição de Risco , Idoso , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/epidemiologia , Migração do Implante de Lente Intraocular/etiologia , Áustria/epidemiologia , Síndrome de Exfoliação/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pupila , Estudos Retrospectivos , Fatores de Risco , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...