J Refract Surg ; 40(7): e438-e444, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007810

RESUMO

PURPOSE: To assess the influence of ocular biometric parameters on intraocular lens (IOL) tilt and decentration after cataract surgery. METHODS: Patients scheduled for cataract surgery were screened for inclusion in this prospective cohort study. Tilt and decentration of the crystalline lens and IOL were measured using the CASIA2 (Tomey). Anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were preoperatively measured by the IOLMaster 700 (Carl Zeiss Meditec AG). Multivariate regression analysis was performed to assess the influence of ocular biometric parameters on IOL tilt and decentration after cataract surgery. RESULTS: In total, 191 eyes of 120 patients were included. Age was positively correlated with IOL tilt, whereas ACD and AL were negatively correlated with IOL tilt. A strong positive correlation was found between preoperative crystalline lenses and postoperative IOLs in tilt magnitude (r = 0.769, P < .001) and tilt direction (r = 0.688, P < .001). A positive correlation was found between preoperative and postoperative lens decentration magnitude and decentration direction. Greater postoperative IOL tilt and decentration were significantly associated with greater preoperative crystalline lens tilt (P < .001) and decentration (P = .027). CONCLUSIONS: IOL tilt was greater in older patients. Shorter AL and shallower ACD contributed to greater IOL tilt. The tilt and decentration of the IOL will be greater in patients with greater tilt and decentration of the crystalline lens. [J Refract Surg. 2024;40(7):e438-e444.].


Assuntos
Comprimento Axial do Olho , Biometria , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Humanos , Estudos Prospectivos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Comprimento Axial do Olho/patologia , Idoso de 80 Anos ou mais , Câmara Anterior/patologia , Migração do Implante de Lente Intraocular/fisiopatologia , Cristalino , Acuidade Visual/fisiologia , Adulto , Pseudofacia/fisiopatologia
3.
J Refract Surg ; 40(7): e499-e505, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39007813

RESUMO

PURPOSE: To assess the effects of intraocular lens (IOL) decentration and tilt, as well as age, on postoperative visual function (corrected distance visual acuity [CDVA] and contrast sensitivity) by comparing an extended depth-of-focus IOL using higher order aspheric optics against a monofocal IOL from the same platform. METHODS: This retrospective observational study targeted patients without other eye diseases who underwent surgery to implant the Tecnis Eyhance OptiBlue or the monofocal IOL Tecnis OptiBlue 1-Piece (J&J Vision) during cataract surgery from November 2021 to December 2022. The effects of age, axial length, IOL decentration, tilt, and corneal higher order aberrations (HOAs) on the postoperative 5 m CDVA and area under log contrast sensitivity function (AULCSF) under photopic and scotopic conditions were evaluated within 3 months of surgery. RESULTS: No significant difference was found in postoperative CDVA between the Tecnis Eyhance OptiBlue group (n = 61 eyes) and the Tecnis OptiBlue 1-Piece group (n = 35 eyes), but AULCSF was significantly better in the Tecnis Eyhance OptiBlue group for photopic (1.58 ± 0.13 vs 1.46 ± 0.18; P = .002) and scotopic (1.71 ± 0.11 vs 1.59 ± 0.19; P = .002) eyes. Multivariate analysis showed a negative correlation between AULCSF and IOL decentration and age in the Tecnis Eyhance OptiBlue group (P < .01), with no significant correlation with tilt, axial length, and corneal HOAs. CONCLUSIONS: The Tecnis Eyhance OptiBlue yielded significantly better contrast sensitivity under photopic and scotopic conditions than the Tecnis OptiBlue 1-Piece. However, it is important to consider the effects of IOL decentration and age when evaluating the contrast sensitivity of the Tecnis Eyhance OptiBlue. [J Refract Surg. 2024;40(7):e499-e505.].


Assuntos
Sensibilidades de Contraste , Percepção de Profundidade , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Desenho de Prótese , Pseudofacia , Acuidade Visual , Humanos , Estudos Retrospectivos , Acuidade Visual/fisiologia , Masculino , Feminino , Sensibilidades de Contraste/fisiologia , Idoso , Pessoa de Meia-Idade , Pseudofacia/fisiopatologia , Percepção de Profundidade/fisiologia , Refração Ocular/fisiologia , Migração do Implante de Lente Intraocular/fisiopatologia , Idoso de 80 Anos ou mais , Período Pós-Operatório , Comprimento Axial do Olho , Aberrações de Frente de Onda da Córnea/fisiopatologia
4.
Int Ophthalmol ; 44(1): 203, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671195

RESUMO

PURPOSE: This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery. METHODS: This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingdao Eye Hospital. Tilt and decentration of IOL was measured using Scheimpflug system (Pentacam) at 1 month and 2 years postoperatively. RESULTS: All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± 0.950° in the vertical plane and 2.399° ± 0.898° in the horizontal plane at 1 month postoperatively, and the mean length of the decentration was 0.207 ± 0.081 mm in vertical plane and 0.211 ± 0.090 mm in the horizontal plane. Compared with 1 month after surgery, the angle of tilt decreased by a mean of 0.192° and decentration increased by a mean of 0.014 mm at the vertical meridian at 2 years postoperatively (P = 0.37 and P = 0.27, respectively), meanwhile, tilt increased by 0.265° and decentration increased by 0.012 mm at the horizontal meridian (P = 0.11 and P = 0.22, respectively). CONCLUSIONS: The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in children above the age of 5. TRIAL REGISTRATION: The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155).


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares Multifocais , Acuidade Visual , Humanos , Masculino , Feminino , Estudos Prospectivos , Catarata/complicações , Catarata/fisiopatologia , Pré-Escolar , Criança , Extração de Catarata/métodos , Extração de Catarata/efeitos adversos , Seguimentos , Desenho de Prótese , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/fisiopatologia , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/cirurgia , Implante de Lente Intraocular/métodos , Lactente
5.
Graefes Arch Clin Exp Ophthalmol ; 262(8): 2541-2550, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38526773

RESUMO

PURPOSE: This study aimed to investigate the in vitro tolerance to decentration of biaspheric intraocular lens (IOLs) with refractive phase-ring extended depth-of-focus (EDOF) and diffractive trifocal designs. METHODS: This experimental study was carried out at the Department of Optics and Optometry and Vision Science, University of Valencia, Spain. The modulation transfer function (MTF) of the ETLIO130C EDOF and the TFLIO130C trifocal IOLs (AST Products Inc., Billerica, MA, USA) were determined at different levels of decentration for a given wavelength and pupil diameter using the PMTF optical bench (Lambda-X Ophthalmics, Nivelles, Belgium). The modulation transfer function (MTF) curves, the through-focus MTF curves, and the Strehl ratios were measured at 3-mm pupil aperture for 0.25-, 0.50- and 0.75-mm decentration. RESULTS: The optical design of the trifocal TFLIO130C IOL is robust to small decentrations, with virtually no change in MTF response for 0.25 mm decentration. For greater decentration levels, the MTF response is slightly reduced with increasing decentration. The ETLIO130C EDOF design is robust to decentration, as the MTF response is only minimally affected when increasing the decentration up to 0.75 mm. CONCLUSIONS: MTF responses are slightly reduced with greater levels of decentration, but the range of focus provided by both trifocal and EDOF designs are preserved. The effects for average levels of decentration reported in the literature are minimum for both IOL designs.


Assuntos
Desenho de Prótese , Refração Ocular , Refração Ocular/fisiologia , Humanos , Óptica e Fotônica , Percepção de Profundidade/fisiologia , Lentes Intraoculares , Acuidade Visual/fisiologia , Lentes Intraoculares Multifocais , Migração do Implante de Lente Intraocular/fisiopatologia
6.
J Cataract Refract Surg ; 50(8): 805-809, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38529959

RESUMO

PURPOSE: To use a combination of partial least squares regression and a machine learning approach to predict intraocular lens (IOL) tilt using preoperative biometry data. SETTING: Kepler University Clinic Linz, Linz, Austria. DESIGN: Prospective single-center study. METHODS: Optical coherence tomography, autorefraction, and subjective refraction were performed at baseline and 8 weeks after cataract surgery. In analysis I, only 1 eye per patient was included and a tilt prediction model was generated. In analysis II, a pairwise comparison between right and left eyes was performed. RESULTS: In analysis I, 50 eyes of 50 patients were analyzed. Difference in amount, orientation, and vector from preoperative to postoperative lens tilt was -0.13 degrees, 2.14 degrees, and 1.20 degrees, respectively. A high predictive power (variable importance for projection [VIP]) for postoperative tilt prediction was found for preoperative tilt (VIP = 2.2), pupil decentration (VIP = 1.5), lens thickness (VIP = 1.1), axial eye length (VIP = 0.9), and preoperative lens decentration (VIP = 0.8). These variables were applied to a machine learning algorithm resulting in an out of bag score of 0.92 degrees. In analysis II, 76 eyes of 38 patients were included. The difference of preoperative to postoperative IOL tilt of right and left eyes of the same individual was statistically relevant. CONCLUSIONS: Postoperative IOL tilt showed excellent predictability using preoperative biometry data and a combination of partial least squares regression and a machine learning algorithm. Preoperative lens tilt, pupil decentration, lens thickness, axial eye length, and preoperative lens decentration were found to be the most relevant parameters for this prediction model.


Assuntos
Biometria , Implante de Lente Intraocular , Lentes Intraoculares , Aprendizado de Máquina , Facoemulsificação , Refração Ocular , Tomografia de Coerência Óptica , Humanos , Estudos Prospectivos , Biometria/métodos , Masculino , Refração Ocular/fisiologia , Feminino , Tomografia de Coerência Óptica/métodos , Idoso , Pessoa de Meia-Idade , Migração do Implante de Lente Intraocular/fisiopatologia , Pseudofacia/fisiopatologia , Acuidade Visual/fisiologia
7.
Am J Ophthalmol ; 262: 206-212, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38373583

RESUMO

PURPOSE: To report and evaluate a multicenter series of 18 cases of severe, spontaneous IOL tilt involving the flanged intrascleral haptic fixation technique (FISHF). DESIGN: Clinical study with historical controls. METHODS: We report a cross-sectional study of 46 FISHF cases using the CT Lucia 602 IOL at a single academic center over a period of 24 weeks to determine the incidence of severe rotisserie-style rotational tilt. These rates were then compared with the same time-frame the prior year to help determine if this is a new phenomenon. Additional cases of severe tilt were solicited from another 4 academic centers. RESULTS: Among 46 FISHF cases at a single center, 5 developed severe tilt. No clear pattern in surgical technique, ocular history, or ocular anatomy was evident in these cases compared with controls, although the involved IOLs clustered within a narrow diopter range, indicative of a batch effect. In the same 24-week interval the year before, 33 FISHF cases were performed, none of which exhibited severe rotational tilt. In our multicenter dataset, 18 cases of tilt were identified. Surgeons included fellow and early-career physicians as well as surgeons with multiple years of experience with the Yamane technique. A variety of surgical approaches for FISHF were represented. In at least 8 of the cases, haptic rotation and/or dehiscence at the optic-haptic junction were documented. CONCLUSIONS: The identification of haptic rotation and dehiscence intraoperatively in several cases may reflect a new stability issue involving the optic-haptic junction.


Assuntos
Migração do Implante de Lente Intraocular , Implante de Lente Intraocular , Lentes Intraoculares , Esclera , Humanos , Esclera/cirurgia , Estudos Transversais , Implante de Lente Intraocular/métodos , Feminino , Masculino , Idoso , Migração do Implante de Lente Intraocular/cirurgia , Migração do Implante de Lente Intraocular/fisiopatologia , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Idoso de 80 Anos ou mais , Facoemulsificação
8.
Acta Ophthalmol ; 102(5): e805-e812, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38292001

RESUMO

PURPOSE: The purpose of this study was to compare the tilt and decentration of one-piece anti-vaulting haptic intraocular lenses (IOL) and three-piece C-loop haptic IOLs in paediatric eyes undergoing secondary IOL implantation into the ciliary sulcus. METHODS: Paediatric aphakic patients receiving either one-piece anti-vaulting haptic or three-piece C-loop haptic IOL implants into the ciliary sulcus were enrolled in this prospective non-randomized interventional study and followed up for 3 years. IOL decentration and tilt were measured using Scheimpflug images. Preoperative and postoperative information, including demographic data and ocular biometric parameters and complications, were collected and analysed. RESULTS: Among 123 eyes of 79 paediatric patients, there were 72 eyes (58.54%) in the anti-vaulting haptic IOL group and 51 eyes (41.46%) in the C-loop haptic group. The anti-vaulting haptic IOL group had a lower incidence of clinically significant vertical IOL decentration than the C-loop haptic IOL group (23.88% vs. 43.14%, p = 0.037). No intergroup differences were observed in vertical or horizontal tilt or in horizontal decentration (all p > 0.05). One-piece anti-vaulting haptic IOL implantation was associated with a lower risk of clinically significant vertical decentration than three-piece C-loop haptic IOL implantation (odds ratio: 0.42, p = 0.037). There was a higher incidence of IOL dislocation in the C-loop haptic IOL group (15.22% vs. 4.17%, p = 0.046). CONCLUSIONS: In paediatric aphakic eyes undergoing secondary IOL implantation into the ciliary sulcus, one-piece anti-vaulting haptic IOLs can reduce the risk of clinically significant vertical IOL decentration compared with three-piece C-loop haptic IOLs and may favour long-term IOL positional stability.


Assuntos
Corpo Ciliar , Implante de Lente Intraocular , Lentes Intraoculares , Desenho de Prótese , Acuidade Visual , Humanos , Estudos Prospectivos , Masculino , Feminino , Lentes Intraoculares/efeitos adversos , Pré-Escolar , Seguimentos , Corpo Ciliar/cirurgia , Implante de Lente Intraocular/métodos , Criança , Afacia Pós-Catarata/fisiopatologia , Afacia Pós-Catarata/cirurgia , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/prevenção & controle , Migração do Implante de Lente Intraocular/fisiopatologia , Lactente , Refração Ocular/fisiologia , Complicações Pós-Operatórias/epidemiologia , Fatores de Tempo
9.
Appl Opt ; 60(20): 5917-5924, 2021 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-34263818

RESUMO

Intraocular lens (IOL) misalignment and angle κ have had significant negative impact on post-operative quality of vision. ZEMAX software has been used to imitate the optical performance of pseudophakic eyes with different IOL surface designs at different orientations of IOL misalignment (decentration of 0.4 mm and tilt of 7°, and with the existence of 0.5 mm angle κ). We found that an aspheric balanced curve optic surface maintained better optical performance via inducing less coma aberration. Coma aberration played an unexpectedly important role in the optical performance. With angle κ, the impact of IOL misalignment on visual quality was associated with the orientation of decentration and tilt, indicating that the coma compensation also took effect in pseudophakic eyes. Due to the high incidence of post-operative IOL misalignment, our results provide evidence of the importance of considering personalized angle κ before cataract surgery for patients.


Assuntos
Segmento Anterior do Olho/fisiopatologia , Migração do Implante de Lente Intraocular/fisiopatologia , Lentes Intraoculares , Pseudofacia/fisiopatologia , Acuidade Visual/fisiologia , Humanos , Implante de Lente Intraocular , Modelos Teóricos , Facoemulsificação , Desenho de Prótese
10.
Curr Eye Res ; 46(11): 1673-1680, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34121551

RESUMO

Purpose: To evaluate rotational stability, tilt and decentration of a new monofocal IOL with a 7.0 mm optic and frame haptics.Methods: Prospective post-market clinical follow-up study at the Kepler University Hospital Linz, Austria. An Aspira-aXA (HumanOptics, Germany) was implanted in 74 eyes of 42 cataract patients. The lens was manufactured with toric markings. IOL rotational stability was evaluated by comparing its position at the end of surgery (EoS) versus 1 day, 1 week, 1 month and 4 months postoperatively. IOL tilt and decentration were measured using a Scheimpflug camera at 1 week, 1 month and 4 months.Results: Median absolute IOL rotation was 1.42 degrees (n = 52; mean = 2.18 ± 2.23°) within 1 day after surgery and was significantly higher compared to all later intervals (median <1.0 degree; P = .001). At the 4 months follow-up, IOL rotation was within 5.0 degrees in 85% of the eyes (n = 40) and within 10.0 degrees in 98% (n = 46) of the eyes. The only eye with an IOL rotation of ≥ 10.ty0 degrees (EoS vs. 1 day) had an AL of 26.45 mm. At the last follow-up, the IOL vertical and horizontal tilt referenced to the pupillary axis was in average less than 1.5 degrees in both eyes (n = 54; maximum 5.85°). Decentration in both meridians was on average less than 0.10 mm in both eyes (maximum 0.30 mm).Conclusion: The one-piece Aspira-aXA IOL showed good and stable positioning within the capsular bag over a 4 months period.


Assuntos
Migração do Implante de Lente Intraocular/fisiopatologia , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Pseudofacia/fisiopatologia , Rotação , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Fotografação/instrumentação , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Refração Ocular/fisiologia
11.
Am J Ophthalmol ; 225: 27-37, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33412122

RESUMO

PURPOSE: To evaluate stability and performance of a new monofocal anterior capsulotomy-fixated intraocular lens (IOL) (FEMTIS; Teleon Surgical B.V., Spankeren, Netherlands) after femtosecond laser-assisted cataract surgery (FLACS). DESIGN: Prospective, multicenter, interventional, noncomparative case series. METHODS: FLACS with FEMTIS IOL was performed in 336 eyes of 183 cataract patients with fixation of the IOL to the anterior capsulotomy followed up for 12 months. Examination included uncorrected distance visual acuity (UDVA), best-corrected visual acuity (CDVA), subjective refraction, IOL centration, posterior capsule opacification (PCO), and investigators' satisfaction questionnaire. RESULTS: At 12 months, mean IOL rotation was 1.50 ± 1.76 degrees and decentration 0.14 ± 0.14 mm from baseline (day of surgery). Mean horizontal IOL tilt was 0.70 ± 0.60 degrees and vertical 1.15 ± 1.06 degrees relative to the baseline (crystalline lens). Mean distance between IOL and iris was 0.32 mm to 0.36 mm for all measured meridians. Mean UDVA was 0.12 ± 0.14 logMAR (range -0.20 to 0.54 logMAR), mean CDVA -0.01 ± 0.09 logMAR (range -0.30 to 0.20 logMAR). Mean spherical equivalent was 0.35 ± 0.53 diopter (D) and 98% of eyes (n = 235) were within ±1.0 D. Median PCO score was 1 with an Nd:YAG laser rate of 3.1% after 12 months. Most surgeons were very satisfied (median score: 1) with surgery and implanted IOL. CONCLUSIONS: Implantation of FEMTIS IOL provided excellent visual and stable refractive outcomes. IOL decentration was very low compared to other published studies and showed an exceptional high in-the-bag stability over a 12-month period. This lens benefits from femtosecond laser capsulotomies. It can be positioned very predictably and offers an optimal platform for toric and multifocal IOL optics.


Assuntos
Cápsula Anterior do Cristalino/cirurgia , Migração do Implante de Lente Intraocular/fisiopatologia , Extração de Catarata , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Acuidade Visual/fisiologia , Idoso , Idoso de 80 Anos ou mais , Opacificação da Cápsula/fisiopatologia , Topografia da Córnea , Feminino , Humanos , Terapia a Laser , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Estudos Prospectivos , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Resultado do Tratamento
12.
Am J Ophthalmol ; 224: 150-157, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33309811

RESUMO

PURPOSE: The study was performed to evaluate the refractive and visual outcome of patients with misaligned toric intraocular lenses (IOLs) after operative realignment, with and without back-calculation of the toric axis after implantation of the IOL. DESIGN: Institutional, retrospective case-control study. METHODS: This is a retrospective case series of 39 patients who underwent a second operation to realign a misaligned toric IOL from August 2013 to December 2019 at the Department of Ophthalmology, Goethe University, Frankfurt, Germany. Ideal toric axis was calculated using the back-calculator astigmatismfix.com. RESULTS: The study consists of 39 treated eyes (20 [51%] right eyes). The toric IOLs showed a postoperative misalignment of 25.69 ± 26.06°. Postrotational, uncorrected distance visual acuity (UDVA) improved from 0.39 ± 0.29 logMAR to 0.27 ± 0.18 logMAR. Refractive outcome showed a reduction of residual sphere and cylinder. The postoperative UDVA when performing alignment to the preoperative calculated axis (51%) was 0.24 ± 0.16 logMAR with a cylinder of 0.90 ± 0.90 diopter (D). In the group with alignment to a back-calculated axis (49%), the UDVA was 0.32 ± 0.20 logMAR with a cylinder of 0.76 ± 0.72 D. High cylinder power IOLs (≥2 D) showed a higher decrease in residual cylinder when back-calculation was performed than low cylinder power IOLs (<2 D) (27% vs 9%). The mean spherical equivalent prediction error of the back-calculator was 0.54 ± 0.55 D. CONCLUSION: Realignment of misaligned toric IOLs improves visual acuity and reduces residual refractive errors. Especially for high cylinder power IOLs, better refractive outcome can be seen when performing a back-calculation before realignment.


Assuntos
Migração do Implante de Lente Intraocular/fisiopatologia , Astigmatismo/fisiopatologia , Implante de Lente Intraocular , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Idoso , Migração do Implante de Lente Intraocular/cirurgia , Astigmatismo/cirurgia , Biometria , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
13.
Am J Ophthalmol ; 219: 253-260, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32621898

RESUMO

PURPOSE: We compared rates of intraocular lens (IOL) decentration, neodymium-doped yttrium aluminum garnet capsulotomy for posterior capsule opacification (PCO), and visual acuity (VA) in eyes with and without pseudoexfoliation (PEX) 5 years after undergoing cataract surgery. DESIGN: Prospective comparative interventional study. METHODS: This multicenter study population included 1 eye of both 930 cataract patients with and 470 cataract patients without uncomplicated PEX (no small pupils or phacodonesis) all undergoing phacoemulsification by experienced Aravind Eye Care System surgeons. Eyes were randomized to either 1- or 3-piece intraocular lenses (IOLs). PEX eyes were also randomized to either receive or not receive a capsule tension ring. The main outcome measures included IOL decentration and PCO. Secondary outcomes included postoperative best-corrected VA. RESULTS: Follow-up was 86.2% in the PEX group and 86.7% in the control group at 5 years. The PEX group was older (P < .001) and had more men (P = .01). IOL decentration at 5 years was equally prevalent in PEX and control eyes (1.0% vs 1.1%, respectively, P = .8). Neodymium-doped yttrium aluminum garnet posterior capsulotomy rates for PCO were similar in the PEX group when compared with control subejcts (5.3% compared with 3.2%, respectively, P = .07). Best corrected VA was better at baseline and years 2 and 3 in the control group (P = .0001, P = .0005, and P = .02); however, there was no difference in BCVA at years 1, 4, and 5 between the PEX and control groups (P = .09, P = .29, and P = .5). CONCLUSION: In a large-scale, long-term, prospective comparative study of cataract surgery in eyes with uncomplicated PEX, the risks of IOL decentration and PCO were low and comparable to that in control subjects. When approaching cataract surgery in eyes with relatively uncomplicated PEX, neither IOL choice (1- vs 3-piece acrylic IOL) nor the presence/absence of a capsule tension ring affects outcomes at 5 years.


Assuntos
Migração do Implante de Lente Intraocular/epidemiologia , Opacificação da Cápsula/epidemiologia , Síndrome de Exfoliação/complicações , Lasers de Estado Sólido/uso terapêutico , Lentes Intraoculares , Capsulotomia Posterior/estatística & dados numéricos , Próteses e Implantes , Adulto , Idoso , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/fisiopatologia , Opacificação da Cápsula/cirurgia , Síndrome de Exfoliação/fisiopatologia , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Índia/epidemiologia , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Prospectivos , Desenho de Prótese , Acuidade Visual/fisiologia , Adulto Jovem
14.
Am J Ophthalmol ; 219: 295-302, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32622670

RESUMO

PURPOSE: To evaluate the in vivo durability of the surface and optical properties of the implantable Collamer lens (ICL). DESIGN: Retrospective case series. METHODS: We included patients who developed cataracts after having undergone ICL implantation from March 2003 to May 2014 and underwent ICL explantation followed by cataract surgery from March 2017 to December 2019 at the Nagoya Eye Clinic. ICL explants were submitted to Chukyo Medical Co, Ltd (Nagoya City, Japan) for laboratory analysis using ultraviolet-visible light spectroscopy, light microscopy (LM), and scanning electron microscopy. Patients' demographic and clinical data were collected and reviewed. RESULTS: Thirteen eyes from 10 patients were studied. The average age at ICL explantation was 50.5 ± 8.5 years (range, 34.5-66.3 years). The average length of ICL stay in the eye (from implantation to explantation) was 10.5 ± 2.7 years (range, 4.4-13.7 years). No opacification or coloring of the ICL explants was observed by LM. The ICL explants showed almost the same light transmittance as that of unused ICLs. Scanning electron microscopy revealed no irregularities at the surface of the center and periphery of the optic and haptic footplate. The positioning holes did not show any deposition. CONCLUSION: The ICLs remained in-eye for >10 years without any deterioration in the surface and optical properties of the ICL, despite their contact with the ciliary body and iris tissues and the continuous interaction with the aqueous humor components. The present study shows long-term in vivo stability of the ICL.


Assuntos
Migração do Implante de Lente Intraocular/fisiopatologia , Implante de Lente Intraocular , Luz , Miopia/cirurgia , Óptica e Fotônica , Lentes Intraoculares Fácicas , Adulto , Idoso , Catarata/etiologia , Remoção de Dispositivo , Feminino , Seguimentos , Humanos , Masculino , Microscopia , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Estudos Retrospectivos , Espectrofotometria Ultravioleta
15.
BMC Ophthalmol ; 20(1): 204, 2020 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-32450828

RESUMO

BACKGROUND: A major focus of toric intraocular lens (IOL) implantation is the rotational stability, especially in the patients with long axial length (AL). In this study, we aimed to evaluate the clinical outcomes after implantation of TECNIS toric IOL in eyes with long AL and identify factors influencing their early-stage stability with preoperative corneal astigmatism. METHODS: The study population consisted of 64 eyes from 52 cataract patients, and these patients had preoperative corneal astigmatism between 1.0 and 3.7 diopters (D) and underwent phacoemulsification and TECNIS toric IOL implantation. Ophthalmic biological measurements were carried out preoperatively, including AL, anterior chamber depth (ACD), lens thickness (LT), vitreous length (VL), anterior chamber volume (ACV), sulcus-to-sulcus (STS) and keratometric value (K). Clinical examinations, including visual acuity, manifest refraction, keratometry, digital anterior segment photographs with pupillary dilation, were performed at 1 and 3 months after surgery. RESULTS: The mean best corrected distance visual acuity (BCDVA) was improved from 0.93 ± 0.35 logarithms of the minimal angle of resolution (logMAR) preoperatively to 0.07 ± 0.10 logMAR postoperatively at 3 months after surgery. The mean residual astigmatism (RAS) was 0.91 ± 0.74D at 3 months, which was significantly decreased compared with the preoperative corneal astigmatism of 1.71 ± 0.55 D. The mean absolute rotation of TECNIS toric IOL at 1 and 3 months was 7.42 ± 11.32 degree (°) (0-79°) and 7.48 ± 11.19°(0-79°), respectively. The mean area of capsulorhexis and the overlapped area between capsulorhexis and IOL optic intraoperatively was 21.04 ± 3.30 mm2 and 7.40 ± 2.87 mm2.A positive correlation was found between IOL rotation and the area of capsulorhexis (p = 0.017) at 3 months after surgery. No correlation was found between IOL rotation and AL (p = 0.876), ACD (p = 0.387), LT (p = 0.523), VL (p = 0.546), ACV (p = 0.480), STS (p = 0.884), K1 (p = 0.429), K2 (p = 0.644), average of K1 and K2 (p = 0.520), intraoperative IOL axial direction (p = 0.396), preoperative corneal astigmatism (p = 0.269) or the overlapped area between capsulorhexis and IOL optic intraoperatively (p = 0.131) . CONCLUSIONS: The large CCC was a risk factor for toric IOL rotation. An appropriately smaller sized CCC was conducive to increase the rotational stability of TECNIS toric IOL implantation in cataract cases with long AL.


Assuntos
Migração do Implante de Lente Intraocular/fisiopatologia , Comprimento Axial do Olho/patologia , Catarata/complicações , Implante de Lente Intraocular , Facoemulsificação , Rotação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/patologia , Astigmatismo/fisiopatologia , Capsulorrexe , Feminino , Humanos , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Refração Ocular/fisiologia , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
16.
J Cataract Refract Surg ; 46(2): 179-187, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32126029

RESUMO

PURPOSE: To examine the 6-month outcomes of visual performance and positional stability of a capsule-fixated intraocular lens (IOL), FEMTIS Comfort MF15, extended depth-focus (EDOF) version, after cataract surgery performed using femtosecond laser-assisted cataract surgery capsulotomy. SETTING: Vision Eye Institute, Sydney, Australia. DESIGN: Prospective open-label postregistration data collection. METHODS: Three-month and 6-month outcomes were measured including visual function, stability of IOL position, and quantitative measurement of glare and halo. Subjective patient satisfaction and spectacle independence rates were documented with a subjective questionnaire. A computer simulator was used to quantify the incidence and severity of unwanted visual phenomena allowing comparison with other EDOF and multifocal IOLs. RESULTS: Forty-four eyes of 25 patients were included in the study. There were 19 bilateral cases. The median shift in IOL position over 6 months (from surgery to 6 months) was 0.095 ± 0.09 mm. There was a marked improvement in uncorrected and corrected distance visual acuity from the preoperative to the 6-month mark. Patient satisfaction and spectacle independence levels were high. There was no IOL enclevation, negative dysphotopsia, decentration, or capsular phimosis. CONCLUSIONS: To the authors' knowledge, this is the first study to report outcomes after insertion of the FEMTIS capsulorhexis-fixated EDOF IOL. This IOL offers excellent refractive predictability, functional range of vision, and minimal unwanted visual phenomena. The attachment to the anterior capsulorhexis is shown to be stable over time with no significant shift in the position or capsular phimosis. There was high patient satisfaction with spectacle independence.


Assuntos
Capsulorrexe/métodos , Percepção de Profundidade/fisiologia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Acuidade Visual/fisiologia , Idoso , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/fisiopatologia , Biometria , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Facoemulsificação , Estudos Prospectivos , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Inquéritos e Questionários
17.
Jpn J Ophthalmol ; 64(4): 359-366, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32200517

RESUMO

PURPOSE: To evaluate the impact of vitrectomy and air tamponade on aspheric intraocular lens (IOL) tilt and decentration and postoperative internal higher-order aberrations (HOAs) in combined cataract surgery and vitrectomy (phacovitrectomy). STUDY DESIGN: Prospective comparative observational study. METHODS: Forty-five eyes that underwent phacovitrectomy using aspheric IOLs and 18 eyes that only underwent cataract surgery also using aspheric IOLs were prospectively evaluated. The subjects were divided into three groups: phacovitrectomy without fluid-air exchange (F/Ax) or with F/Ax and cataract surgery alone (Groups A, B, and C, respectively) Surgery-induced changes in lens tilt and decentration and internal HOAs were compared between each pair of groups. Subgroup analysis was conducted for cases with largely tilted (> 7°) or decentered (> 0.40 mm) IOLs 1 month postoperatively. RESULTS: Surgery-induced changes in lens tilt in Group B were significantly more pronounced than those in Group C at 1 week, 1 month, and 3 months postoperatively (P = 0.007, 0.009, and 0.043, respectively), while there was no significant difference in surgery-induced changes in lens decentration among the groups. IOLs in Group B were tilted and decentered toward the inferonasal direction. In contrast, there was no significant difference in internal HOAs among the groups at any postoperative visit. Only Group B included cases with largely decentered IOLs, and the internal total HOAs in these cases were significantly larger than those in the others (P = 0.015). CONCLUSION: Although largely decentered IOLs were occasionally found in Group B, aspheric IOLs could be effectively used in phacovitrectomy.


Assuntos
Migração do Implante de Lente Intraocular/fisiopatologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Tamponamento Interno , Implante de Lente Intraocular , Facoemulsificação , Vitrectomia , Idoso , Ar , Extração de Catarata , Feminino , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Estudos Prospectivos , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Microscopia com Lâmpada de Fenda , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
18.
Am J Ophthalmol ; 218: 314-319, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32222364

RESUMO

PURPOSE: To evaluate the outcome and viability of a modified self-sealing scleral pocket technique for scleral fixation of an intraocular lens (IOL). DESIGN: Retrospective interventional case series. METHODS: A retrospective, interventional case series in which 81 eyes underwent this modified technique, performed in the previous 4 years. Cases included a dislocated IOL and an absent posterior capsule or subluxated cataract. Two diagonally opposed paralimbal, curved self-sealing scleral pockets were made 3 mm away from the limbus along with a vitrectomy. A multipiece IOL was used, and the haptics were fixed under the scleral pockets inside a linear scleral tunnel underneath the superficial scleral flap. The conjunctiva was opposed by using cautery. Postoperatively, anterior segment optical coherence tomography (AS-OCT) was performed in order to detect intrascleral hyper-reflective cross-section of the haptics and optic tilt. The optic position was re-evaluated using ultrasound biomicroscopy (UBM). Main outcomes were mean pre- and postoperative best corrected visual acuity (BCVA), postoperative astigmatism. Postoperative AS-OCT was performed to detect the position of the haptics and optics. UBM was done to recheck any optic tilt. RESULTS: Mean pre- and postoperative BCVA were LogMAR 1.2 ± 0.59 and LogMAR 0.47 ± 0.3 (P < 0.001). Mean postoperative astigmatism was 1.27 ± 1.02 Dcyl. In AS-OCT, an intrascleral hyper-reflective shadow signified stable haptics without any optic tilt. UBM also showed a stable position of the IOL optic without any tilt. CONCLUSIONS: This modified, simple way of scleral fixation of an IOL decreases the duration of surgery with minimal complication.


Assuntos
Implante de Lente Intraocular/métodos , Esclera/cirurgia , Adolescente , Adulto , Idoso , Afacia Pós-Catarata/fisiopatologia , Afacia Pós-Catarata/cirurgia , Migração do Implante de Lente Intraocular/fisiopatologia , Migração do Implante de Lente Intraocular/cirurgia , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Retalhos Cirúrgicos , Procedimentos Cirúrgicos sem Sutura , Adesivos Teciduais , Acuidade Visual/fisiologia , Vitrectomia
19.
Ophthalmic Res ; 63(2): 165-173, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31846979

RESUMO

PURPOSE: To evaluate which ocular axis, the corneal topographic axis (CTA), pupillary axis (PA) or line of sight (LOS), for measuring the tilt and decentration of intraocular lens (IOL) is most relevant to correct distance visual acuity (CDVA). METHODS: A Scheimpflug device (Pentacam HR) was prospectively used to determine the tilt and decentration of IOLs in vivo 3 months after cataract surgery. A new method was developed to reliably measure PA and LOS. We further evaluated CTA and then used Spearman correlation coefficient and linear regression to assess the correlation between CDVA and IOL displacement based on the data of three different ocular axes. RESULTS: Forty-six eyes from 46 patients were evaluated. The majority of decentration and tilt of IOL with reference to CTA, PA and LOS were towards the subtemporal direction. We found that the horizontal meridian data measured using CTA and PA were statistically significantly different (p = 0.011 for tilt; p = 0.005 for decentration). The correlation between CDVA and the distance of decentration temporally (r = -0.344, p = 0.035) and inferiorly (r = -0.336, p = 0.042) of the IOL with regard to CTA was significant. PA and LOS measurements had no correlation with any indices. CONCLUSION: Assessment of tilt and decentration of the IOL with reference to different ocular axes was markedly different. IOL tilt and decentration measured by CTA were significantly correlated with CDVA.


Assuntos
Migração do Implante de Lente Intraocular/fisiopatologia , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares/efeitos adversos , Refração Ocular/fisiologia , Acuidade Visual , Idoso , Idoso de 80 Anos ou mais , Córnea/patologia , Topografia da Córnea , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
20.
Retin Cases Brief Rep ; 14(4): 321-323, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-29443805

RESUMO

BACKGROUND/PURPOSE: To describe a novel use of the flexible nitinol loop membrane scraper (FINESSE Flex loop; Alcon, Fort Worth, TX) for rescue and refixation of a dislocated intraocular lens (IOL). METHODS: A 27-gauge nitinol flex loop was used to lasso each haptic of a dislocated 3-piece IOL. By retracting the loop, the haptic could be effectively locked to the instrument and externalized through a scleral tunnel, thereby fixating it to the sclera in a sutureless fashion. RESULTS: A 50-year-old man presented with a posteriorly dislocated Sensar AR40e IOL (Abbott Medical Optics, Inc; Santa Barbara, CA) and retained lens material after a complicated cataract surgery in the left eye. His visual acuity was counting fingers at face. The patient underwent 27-gauge pars plana vitrectomy with successful rescue and refixation of the IOL using the nitinol flex loop. One week postoperatively, his visual acuity had improved to 20/40. CONCLUSION: The nitinol flex loop may be used to lasso the haptics of a dislocated IOL and refixate it using a sutureless intrascleral fixation technique. This instrument may be a safer alternative compared with forceps for retrieving posteriorly dislocated IOLs that are sitting on the retinal surface.


Assuntos
Ligas , Migração do Implante de Lente Intraocular/cirurgia , Implante de Lente Intraocular/instrumentação , Lentes Intraoculares , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/fisiopatologia , Humanos , Implante de Lente Intraocular/métodos , Masculino , Pessoa de Meia-Idade , Pseudofacia/fisiopatologia , Estudos Retrospectivos , Retalhos Cirúrgicos , Procedimentos Cirúrgicos sem Sutura , Acuidade Visual/fisiologia , Vitrectomia