1.
Optom Vis Sci ; 98(5): 437-439, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33973909

RESUMO

SIGNIFICANCE: We report the use of anterior segment optical coherence tomography (AS-OCT) as a valuable tool for capsular block syndrome diagnosis and follow-up. PURPOSE: The purposes of this study are to report a case of late-onset capsular block syndrome or lacteocrumenasia and to describe differential diagnosis with other more common phacoemulsification complications such as intraocular lens (IOL) or posterior capsule opacification. CASE REPORT: We report the case of a 56-year-old man with a clinical history of cataract surgery in his left eye. Five years after cataract surgery, he complained of blurred vision and was referred for IOL removal to our hospital. After careful slit-lamp examination, we found that the lens was clear, and opacity belonged to the accumulation of a whitish material in the capsular bag behind the lens. AS-OCT gave the definite diagnosis of capsular block syndrome. Intraocular lens removal had been wrongly indicated, and we treated our patient by YAG laser posterior capsulotomy. AS-OCT confirmed the absence of a further accumulated material, so no other interventions were needed. After treatment, best-corrected visual acuity improved from 0.48 to 0.1 logMAR. CONCLUSIONS: Capsular block syndrome is a rare late-onset complication of cataract surgery causing a deep visual acuity decay. A precise slit-lamp examination and AS-OCT, together, avoid misdiagnosis and unnecessary surgical treatment, which may be needed in case of IOL opacity or fibrotic-like lacteocrumenasia. AS-OCT also helps in determining the treatment outcome. Immediate best-corrected visual acuity improvement is reached after a successful intervention.


Assuntos
Opacificação da Cápsula/diagnóstico por imagem , Cápsula Posterior do Cristalino/diagnóstico por imagem , Complicações Pós-Operatórias , Tomografia de Coerência Óptica , Opacificação da Cápsula/etiologia , Opacificação da Cápsula/fisiopatologia , Opacificação da Cápsula/cirurgia , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Cápsula Posterior do Cristalino/fisiopatologia , Cápsula Posterior do Cristalino/cirurgia , Capsulotomia Posterior , Tomografia de Coerência Óptica/métodos , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia
2.
Exp Eye Res ; 205: 108487, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33571531

RESUMO

Intraocular lenses (IOLs) are implanted during cataract surgery. For optimum results, stable positioning of the IOL in the capsular bag is important. Wound-healing events following cataract surgery lead to modification of the capsular bag and secondary visual loss due to posterior capsule opacification. At present, it is unclear how these biological events can affect stability of the IOL within the capsular bag. In the present study, a human in vitro graded culture capsular bag model was the experimental system. Capsulorhexis and lens extraction performed on human donor eyes generated suspended capsular bags (5 match-paired experiments). Preparations were secured by pinning the ciliary body to a silicone ring and maintained in 6 mL of medium for 84 days using a graded culture system: days 1-3, 5% human serum and 10 ng/mL transforming growth factor ß (TGFß2); days 4-7, 2% human serum and 1 ng/mL TGFß2; days 8-14, 1% human serum and 0.1 ng/mL TGFß2; days 15-84, serum-free Eagle's minimum essential medium (EMEM). A CT LUCIA 611PY IOL was implanted in all preparations. Quantitative measures were determined from whole bag images captured weekly. Images were registered using FIJI and analysed in ImageJ to determine capsular bag area; distortion; angle of contact; haptic stability; capsulorhexis area; and a fusion footprint associated with connection between the anterior and posterior capsules. Cell coverage and light scatter were quantified at end-point. The transdifferentiation marker, α-SMA was assessed by immunocytochemistry. Immediately following surgery, distortion of the capsular bag was evident, such that a long axis is generated between haptics relative to the non-haptic regions (short axis). The angle of contact between the haptics and the peripheral bag appeared inversely correlated to capsular bag area. Growth on the peripheral posterior capsule was observed 1 week after surgery and beneath the IOL within 1 month. As coverage of the posterior capsule progressed this was associated with matrix contraction/wrinkles of both the central posterior capsule and peripheral capsular bag. Cells on the central posterior capsule expressed αSMA. Fusion footprints formed in non-haptic regions of the peripheral bag and progressively increased over the culture period. Within and at the edge of the fusion footprint, refractive structures resembling lens fibre cells and Elschnig's pearls were observed. Cell attachment to the IOL was limited. An impression in the posterior capsule associated with the CT LUCIA 611PY optic edge was evident; cell density was much greater peripheral to this indent. Wound-healing events following surgery reduced capsular bag area. This was associated with the long/short axis ratio and angle of contact increasing with time. In summary, we have developed a human capsular bag model that exhibits features of fibrotic and regenerative PCO. The model permits biomechanical information to be obtained that enables better understanding of IOL characteristics in a clinically relevant biological system. Throughout culture the CT LUCIA 611PY appeared stable in its position and capsular bag modifications did not change this. We propose that the CT LUCIA 611PY optic edge shows an enhanced barrier function, which is likely to provide better PCO management in patients.


Assuntos
Opacificação da Cápsula/fisiopatologia , Extração de Catarata , Elasticidade/fisiologia , Cápsula do Cristalino/fisiologia , Implante de Lente Intraocular , Lentes Intraoculares , Cápsula Posterior do Cristalino/fisiopatologia , Actinas/metabolismo , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Opacificação da Cápsula/metabolismo , Capsulorrexe , Feminino , Fibronectinas/metabolismo , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Técnicas de Cultura de Órgãos , Cápsula Posterior do Cristalino/metabolismo
3.
Am J Ophthalmol ; 225: 27-37, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33412122

RESUMO

PURPOSE: To evaluate stability and performance of a new monofocal anterior capsulotomy-fixated intraocular lens (IOL) (FEMTIS; Teleon Surgical B.V., Spankeren, Netherlands) after femtosecond laser-assisted cataract surgery (FLACS). DESIGN: Prospective, multicenter, interventional, noncomparative case series. METHODS: FLACS with FEMTIS IOL was performed in 336 eyes of 183 cataract patients with fixation of the IOL to the anterior capsulotomy followed up for 12 months. Examination included uncorrected distance visual acuity (UDVA), best-corrected visual acuity (CDVA), subjective refraction, IOL centration, posterior capsule opacification (PCO), and investigators' satisfaction questionnaire. RESULTS: At 12 months, mean IOL rotation was 1.50 ± 1.76 degrees and decentration 0.14 ± 0.14 mm from baseline (day of surgery). Mean horizontal IOL tilt was 0.70 ± 0.60 degrees and vertical 1.15 ± 1.06 degrees relative to the baseline (crystalline lens). Mean distance between IOL and iris was 0.32 mm to 0.36 mm for all measured meridians. Mean UDVA was 0.12 ± 0.14 logMAR (range -0.20 to 0.54 logMAR), mean CDVA -0.01 ± 0.09 logMAR (range -0.30 to 0.20 logMAR). Mean spherical equivalent was 0.35 ± 0.53 diopter (D) and 98% of eyes (n = 235) were within ±1.0 D. Median PCO score was 1 with an Nd:YAG laser rate of 3.1% after 12 months. Most surgeons were very satisfied (median score: 1) with surgery and implanted IOL. CONCLUSIONS: Implantation of FEMTIS IOL provided excellent visual and stable refractive outcomes. IOL decentration was very low compared to other published studies and showed an exceptional high in-the-bag stability over a 12-month period. This lens benefits from femtosecond laser capsulotomies. It can be positioned very predictably and offers an optimal platform for toric and multifocal IOL optics.


Assuntos
Cápsula Anterior do Cristalino/cirurgia , Migração do Implante de Lente Intraocular/fisiopatologia , Extração de Catarata , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Acuidade Visual/fisiologia , Idoso , Idoso de 80 Anos ou mais , Opacificação da Cápsula/fisiopatologia , Topografia da Córnea , Feminino , Humanos , Terapia a Laser , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Estudos Prospectivos , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Resultado do Tratamento
4.
Ophthalmology ; 127(9): 1220-1226, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32312636

RESUMO

PURPOSE: Appropriate correction of aphakia is key to good outcomes. There may be clinical settings where and populations in whom accessing or managing aphakic contact lenses is challenging. Strategies to target the increased risk of visual axis opacity (VAO) after primary intraocular lens (IOL) implantation in infancy are necessary. We describe the predictors of VAO after primary IOL implantation for unilateral or bilateral congenital or infantile cataract in children younger than 2 years of age. DESIGN: Population-based (United Kingdom and Ireland), prospective, inception cohort study undertaken through a national clinical network. PARTICIPANTS: A total of 105 children (57 with bilateral cataract, 48 with unilateral cataract, total 162 eyes) undergoing primary IOL implantation in the first 2 years of life between January 2009 and December 2010. METHODS: Observational longitudinal study with multilevel, multivariable modeling to investigate associations between outcome of interest and child- and treatment-specific factors, including age, axial length, socioeconomic status, IOL model, and postoperative steroid use. MAIN OUTCOME MEASURES: Postoperative proliferative or inflammatory visual axis opacity (VAO) requiring surgical correction. RESULTS: Visual axis opacity occurred in 67 eyes (45%), typically within the first postoperative year. Use of a 3-piece IOL model (odds ratio [OR], 0.3; 95% confidence interval [CI], 0.09-0.99, P = 0.03) and increasing age at surgery (OR, 0.97, 95% CI, 0.95-0.99, P = 0.02) were each independently protective against the development of proliferative VAO. Inflammatory VAO was independently associated with socioeconomic deprivation (OR, 5.39; 95% CI, 1.46-19.89; P = 0.01). CONCLUSIONS: Visual axis opacification is common after IOL implantation in early childhood. The findings of this prospective cohort study suggest that the use of 3-piece IOL models may reduce the risk of pseudophakic VAO in children younger than 2 years of age.


Assuntos
Opacificação da Cápsula/etiologia , Extração de Catarata , Implante de Lente Intraocular , Complicações Pós-Operatórias , Pseudofacia/etiologia , Acuidade Visual/fisiologia , Opacificação da Cápsula/fisiopatologia , Catarata/congênito , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Estudos Longitudinais , Masculino , Estudos Prospectivos , Pseudofacia/fisiopatologia , Reino Unido
5.
Arq. bras. oftalmol ; 82(3): 189-194, May-June 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001312

RESUMO

ABSTRACT Purpose: The purpose of this study was to objectively assess the optical vision quality of patients before and after Nd:YAG capsulotomy for posterior capsular opacification using a double-pass retinal imaging system. Methods: We retrospectively analyzed the data from 26 pseudophakic eyes with posterior capsular opacification that underwent Nd:YAG capsulotomy. The objective scatter indices, modulation transfer function cutoff frequencies, Strehl ratios, and logMAR corrected distance visual acuities were assessed before and after YAG capsulotomy with a double-pass retinal imaging system (OQAS II, Visiometrics, Spain). We also analyzed data from a subgroup of 10 patients with pre-YAG corrected distance visual acuity of 0.10 logMAR (20/25) or better. Results: Vision quality indices improved in all 26 eyes, resulting in a statistically significant improvement in the corrected distance visual acuity (p=0.007), objective scatter index (p=0.001), modulation transfer function cutoff frequency (p=0.001), and Strehl ratio (p=0.020). The overall mean improvements included 0.12 ± 0.04 logMAR for corrected distance visual acuity, 2.84 ± 0.76 for objective scatter index, 12.29 ± 2.77 for modulation transfer function cutoff frequency, and 0.06 ± 0.03 for Strehl ratio. Our sub-analysis of 10 eyes with 0.10 logMAR (20/25) corrected distance visual acuity or better also showed a statistically significant improvement in the mean objective scatter index (0.76 ± 16; p=0.001), resulting in approximately 35% decrease in intraocular light scatter. Conclusions: The objective vision quality measurements as assessed by the double-pass retinal imaging system showed a significant improvement after YAG capsulotomy. This suggests that the objective scatter index improves after YAG capsulotomy, even in eyes with pre-YAG 0.10 logMAR (Snellen 20/25) corrected distance visual acuity or better.


RESUMO Objetivo: Avaliar objetivamente a qualidade da visão óptica antes e depois da capsulotomia com Nd: YAG, obtida por imagem pelo metodo de dupla passagem de luz em pacientes com opacificação capsular posterior. Método: Análise retrospectiva de 26 olhos pseudofácicos com opacificação capsular posterior visualmente significativa, que foram submetidos à capsulotomia de Nd: YAG. O índice de dispersão objetiva, a função de transferência de modulação, a relação de Strehl e a acuidade visual à distância corrigida foram avaliados antes e após a capsulotomia com YAG usando o dupla passagem de luz (OQAS II, Visiometrics, Espanha). Também foi analisado um subgrupo de pacientes com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (20/25) ou melhor. Resultados: Os índices de qualidade da visão melhoraram em todos os 26 olhos, resultando em uma melhora estatisticamente significativa na acuidade visual à distância corrigida (p=0,007), índice de dispersão objetiva (p=0,001), função de transferência de modulação (p=0,001) e relação de Strehl (p=0,020). A melhora média na acuidade visual à distância corrigida foi de 0,12 ± 0,04 logMAR, no índice de dispersão objetiva foi de 2,84 ± 0,76, no função de transferência de modulação foi de 12,29 ± 2,77 e na razão de Strehl foi de 0,06 ± 0,03 em todos os olhos. Sub-análise de 10 olhos com 0.10 logMAR (20/25) acuidade visual à distância corrigida ou melhor também mostrou uma melhora estatisticamente significativa no índice de dispersão objetiva (p=0,001). A melhora média no OSI foi de 0,76 ± 16, uma diminuição de 35% na dispersão da luz intraocular. Conclusões: A qualidade da visão avaliada pelo dupla passagem de luz mostra uma melhora significativa nas medidas objetivas da qualidade da visão após a capsulotomia do YAG. O índice de dispersão objetiva melhora após a capsulotomia YAG, mesmo em olhos com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (Snellen 20/25) ou melhor.


Assuntos
Humanos , Masculino , Feminino , Idoso , Acuidade Visual/fisiologia , Pseudofacia/fisiopatologia , Opacificação da Cápsula/fisiopatologia , Capsulotomia Posterior/reabilitação , Valores de Referência , Retina/fisiopatologia , Retina/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento , Pseudofacia/diagnóstico por imagem , Lasers de Estado Sólido/uso terapêutico , Opacificação da Cápsula/diagnóstico por imagem , Capsulotomia Posterior/métodos
6.
Arq Bras Oftalmol ; 82(3): 189-194, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30810615

RESUMO

PURPOSE: The purpose of this study was to objectively assess the optical vision quality of patients before and after Nd:YAG capsulotomy for posterior capsular opacification using a double-pass retinal imaging system. METHODS: We retrospectively analyzed the data from 26 pseudophakic eyes with posterior capsular opacification that underwent Nd:YAG capsulotomy. The objective scatter indices, modulation transfer function cutoff frequencies, Strehl ratios, and logMAR corrected distance visual acuities were assessed before and after YAG capsulotomy with a double-pass retinal imaging system (OQAS II, Visiometrics, Spain). We also analyzed data from a subgroup of 10 patients with pre-YAG corrected distance visual acuity of 0.10 logMAR (20/25) or better. RESULTS: Vision quality indices improved in all 26 eyes, resulting in a statistically significant improvement in the corrected distance visual acuity (p=0.007), objective scatter index (p=0.001), modulation transfer function cutoff frequency (p=0.001), and Strehl ratio (p=0.020). The overall mean improvements included 0.12 ± 0.04 logMAR for corrected distance visual acuity, 2.84 ± 0.76 for objective scatter index, 12.29 ± 2.77 for modulation transfer function cutoff frequency, and 0.06 ± 0.03 for Strehl ratio. Our sub-analysis of 10 eyes with 0.10 logMAR (20/25) corrected distance visual acuity or better also showed a statistically significant improvement in the mean objective scatter index (0.76 ± 16; p=0.001), resulting in approximately 35% decrease in intraocular light scatter. CONCLUSIONS: The objective vision quality measurements as assessed by the double-pass retinal imaging system showed a significant improvement after YAG capsulotomy. This suggests that the objective scatter index improves after YAG capsulotomy, even in eyes with pre-YAG 0.10 logMAR (Snellen 20/25) corrected distance visual acuity or better.


Assuntos
Opacificação da Cápsula/fisiopatologia , Capsulotomia Posterior/reabilitação , Pseudofacia/fisiopatologia , Acuidade Visual/fisiologia , Idoso , Opacificação da Cápsula/diagnóstico por imagem , Feminino , Humanos , Lasers de Estado Sólido/uso terapêutico , Masculino , Capsulotomia Posterior/métodos , Pseudofacia/diagnóstico por imagem , Valores de Referência , Retina/diagnóstico por imagem , Retina/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento
7.
BMC Ophthalmol ; 19(1): 40, 2019 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-30717688

RESUMO

BACKGROUND: To compare the influence of posterior capsule opacification (PCO) morphology and severity on intraocular stray light and visual function with different levels of contrast. METHODS: Forty-five patients diagnosed with PCO were included in this prospective consecutive case series. The Optical Quality Analysis System II (OQAS II) was adopted to assess the objective visual function including objective scatter index (OSI) and optical quality analysis system values (OVs) with 100, 20, and 9% contrast. RTVue-100 OCT was used to evaluate the PCO morphology and severity. Comparisons among visual function, morphology, and severity between pear type and fibrosis PCO were performed. The correlations among the PCO morphology, severity, OSI, and OVs were also determined. RESULTS: There was a significant correlation between increased OSI and decreased visual acuity in PCO patients before laser capsulotomy. The changes of OSI were also correlated with the PCO area for the 3 mm IOL optic region (r = 0.43, p = 0.02). The OSI was significantly higher in pear type PCO when compared with fibrosis PCO (Z = - 4.06, p ≤ 0.001). In addition, the increased OSI in pear type PCO was significantly correlated with the 100% OVs and the 20% OVs but not with the 9% OVs. In fibrosis PCO, OSI was only correlated with the 100% OVs and the 20% OVs pre-YAG. CONCLUSIONS: OSI and OVs could objectively indicate the visual function impairment in PCO patients. Effects of PCO on light scattering and on objective visual function might be explained by the variations of morphology and severity.


Assuntos
Opacificação da Cápsula/fisiopatologia , Cápsula Posterior do Cristalino/patologia , Adulto , Idoso , Sensibilidades de Contraste/fisiologia , Feminino , Humanos , Implante de Lente Intraocular , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
8.
Cesk Slov Oftalmol ; 72(3): 66-70, 2016.
Artigo em Tcheco | MEDLINE | ID: mdl-27658973

RESUMO

PURPOSE: To prospectively compare postoperative results of two premium intraocular lenses EnVISTA (Bausch and Lomb) and AcrySof IQ (Alcon), focussing on glistenings and posterior capsule opacification. The evaluation of glistenings was done using Image J software and posterior capsule opacifications were quantified with OSCA system. METHODS: Twenty patients (7 men and 13 women) with bilateral cataract were included. EnVista intraocular lens (IOL) was implanted in one eye and AcrySof IQ IOL in the second eye of each patient. Objective evaluation methods were used for assessment. Glistenings was quantified with ImageJ software and PCO using the Open-Access Systematic Capsule Assessment (OSCA) system (Devised by Aslam TM, Edinburgh, United Kingdom). Complete ophthtalmological evaluation including evaluation after pupil dilatation was done and digital images of intraocular lenses were obtained. The results of 2-, 4-, 6- and 12-month follow-up were compared. RESULTS: Twenty patients were analyzed 2 months, 16 patients 4 months, 14 patients 6 months and 13 patients 12 months after cataract surgery. There was only minimal difference in best corrected visual acuity between EnVista and AcrySof group. The glistenings in the EnVista IOLs was objectively lower than in the AcrySof IOLs during whole follow-up period. In contrast to PCO, in eyes with AcrySof IOL was lower PCO score. CONCLUSION: Development of new materials and techniques of cataract surgery is the topic of ophthtalmologists worldwide. Reduction of glistenings and PCO is one of the main aims, objective measurements is important part of assessment of postoperative results after cataract surgery. KEY WORDS: glistenings, posterior capsule opacification, EnVista, AcrySof IQ, Image J software, OSCA system.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação/métodos , Pseudofacia/fisiopatologia , Acuidade Visual/fisiologia , Resinas Acrílicas , Idoso , Opacificação da Cápsula/fisiopatologia , Extração de Catarata , Feminino , Seguimentos , Humanos , Masculino , Período Pós-Operatório , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
9.
PLoS One ; 11(2): e0148553, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26840405

RESUMO

PURPOSE: To establish an optical section-assisted in vivo rabbit model for capsular bend and posterior capsule opacification (PCO) investigation. METHODS: A total of 10 rabbits underwent phacoemulsification surgery and intraocular lens (IOL) implantation. On the basis of the relationship between the anterior capsule and IOL, the rabbits were divided into complete overlap and incomplete overlap groups, in which six and four rabbits were included, respectively. The capsular bend optical sections were assessed using ultra-long scan depth optical coherence tomography (UL-OCT), and posterior capsule opacification was evaluated with slit lamp on postoperative day 3, 7, 14, and 28. In addition, histopathological section was used to verify the accuracy of capsular bend type captured by OCT in three rabbits. RESULTS: Based on the special animal model, six capsular bend types were observed, namely, anterior (A), middle (M), posterior (P), detachment (D), funnel (Fun) and furcate adhesion (Fur). On day 3, capsular bend began to form. On 14 days, the capsular bends were comprised of A, M and D types, which were almost maintained until day 28. Histopathological section findings were consistent with optical sectioning results. In the incomplete and complete groups, the earliest PCO within the optical zone were on day 7 and 28, respectively. The incomplete group exhibited higher incidence and faster PCO on day 7 (p = 0.038) and 14 (p = 0.002). CONCLUSIONS: This animal model not only mimics capsular bend evolution and PCO processes but also produces OCT optical section images equivalent to and more repeatable than histopathology, thereby providing a promising method for the further investigations of PCO.


Assuntos
Opacificação da Cápsula/patologia , Cristalino/patologia , Tomografia de Coerência Óptica , Animais , Opacificação da Cápsula/fisiopatologia , Modelos Animais de Doenças , Cristalino/fisiopatologia , Coelhos
10.
Eye (Lond) ; 30(1): 95-101, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26493036

RESUMO

PurposeTo evaluate the effect of mild posterior capsule opacity (PCO) on visual acuity (VA) in eyes implanted with a diffractive multifocal intraocular lens (IOL) compared with a monofocal IOL, and the effect of posterior continuous curvilinear capsulorhexis (PCCC) combined with diffractive multifocal IOL implantation.MethodsFor the initial evaluation, we compared charge-coupled device (CCD) camera photographs taken through both a monofocal IOL-loaded model eye and a diffractive IOL-loaded model eye under the conditions of both with and without an opaque filter for the simulation of mild PCO. The clinical evaluation involved 20 patients who underwent bilateral implantation of the same diffractive multifocal IOL. In all 20 cases, PCCC was performed in 1 eye (PCCC group) and not performed in the fellow eye (NCCC group). Postoperative clinical results were then compared between the two groups.ResultsThe CCD photographs revealed that the diffractive IOL-loaded eye was more strongly affected by the simulated PCO than was the monofocal IOL-loaded eye. In the clinical setting, the PCCC group registered better results than NCCC group in distance and near VA, low-contrast VA, and contrast sensitivity testing.ConclusionsDiffractive multifocal IOLs tend to be more influenced by mild PCO than do monofocal IOLs, and PCCC prior to IOL implantation can contribute to the avoidance of this effect.


Assuntos
Opacificação da Cápsula/fisiopatologia , Capsulorrexe/métodos , Implante de Lente Intraocular , Lentes Intraoculares , Cápsula Posterior do Cristalino/fisiopatologia , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia , Adulto , Idoso , Sensibilidades de Contraste/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fotografação
11.
Br J Ophthalmol ; 100(2): 263-8, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26089212

RESUMO

PURPOSE: To investigate the 1-year rotational stability of AcrySof Toric intraocular lenses (IOLs) and factors influencing their stability. METHODS: This retrospective study enrolled 75 patients who underwent phacoemulsification, and were implanted with an AcrySof Toric IOL for 1 year. Their preoperative clinical data were reviewed. The 1-year clinical outcomes included uncorrected visual acuity, best-corrected visual acuity and residual astigmatism. Rotation of the IOL and the grade of anterior capsular opacification (ACO; graded from 0=none to 3=severe) were evaluated after mydriasis. RESULTS: Of the 75 eyes analysed, 29.33% had high myopia. Residual astigmatism at 1 year (-0.76±0.47 dioptre(D)) was significantly reduced compared with the preoperative corneal astigmatism (2.08±0.71 D). The mean absolute rotation of the IOL was 8.83±5.26°. Toric IOL rotation was significantly and positively correlated with the degree of residual astigmatism in the T3 (Pearson's r=0.552, p<0.001) and T4 groups (Pearson's r=0.622, p=0.003). Regarding factors associated with IOL rotation, toric IOL rotation was positively correlated with axial length (AXL; Pearson's r=0.335, p=0.003) and negatively correlated with ACO grade (Spearman's r=-0.541, p<0.001). On multiple linear regression analysis, only AXL (B=0.889, p=0.031) and ACO grade (B=-3.216, p<0.001) were predictors of toric IOL rotation (R(2)=0.397). CONCLUSIONS: Long AXL is a risk factor for toric IOL rotation, while higher ACO grade may decrease toric IOL rotation, indicating that reducing the polishing of anterior capsule may improve the rotational stability of a toric IOL. TRIAL REGISTRATION NUMBER: NCT02182921.


Assuntos
Migração do Implante de Lente Intraocular/fisiopatologia , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Rotação , Adulto , Idoso , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Migração do Implante de Lente Intraocular/etiologia , Astigmatismo/fisiopatologia , Comprimento Axial do Olho/fisiopatologia , Opacificação da Cápsula/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Acuidade Visual/fisiologia
12.
Exp Eye Res ; 142: 92-101, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26003864

RESUMO

Cataract is a common age-related condition that is caused by progressive clouding of the normally clear lens. Cataract can be effectively treated by surgery; however, like any surgery, there can be complications and the development of a secondary cataract, known as posterior capsule opacification (PCO), is the most common. PCO is caused by aberrant growth of lens epithelial cells that are left behind in the capsular bag after surgical removal of the fiber mass. An epithelial-to-mesenchymal transition (EMT) is central to fibrotic PCO and forms of fibrotic cataract, including anterior/posterior polar cataracts. Transforming growth factor ß (TGFß) has been shown to induce lens EMT and consequently research has focused on identifying ways of blocking its action. Intriguingly, recent studies in animal models have shown that EMT and cataract developed when a class of negative-feedback regulators, Sprouty (Spry)1 and Spry2, were conditionally deleted from the lens. Members of the Spry family act as general antagonists of the receptor tyrosine kinase (RTK)-mediated MAPK signaling pathway that is involved in many physiological and developmental processes. As the ERK/MAPK signaling pathway is a well established target of Spry proteins, and overexpression of Spry can block aberrant TGFß-Smad signaling responsible for EMT and anterior subcapsular cataract, this indicates a role for the ERK/MAPK pathway in TGFß-induced EMT. Given this and other supporting evidence, a case is made for focusing on RTK antagonists, such as Spry, for cataract prevention. In addition, and looking to the future, this review also looks at possibilities for supplanting EMT with normal fiber differentiation and thereby promoting lens regenerative processes after cataract surgery. Whilst it is now known that the epithelial to fiber differentiation process is driven by FGF, little is known about factors that coordinate the precise assembly of fibers into a functional lens. However, recent research provides key insights into an FGF-activated mechanism intrinsic to the lens that involves interactions between the Wnt-Frizzled and Jagged/Notch signaling pathways. This reciprocal epithelial-fiber cell interaction appears to be critical for the assembly and maintenance of the highly ordered three-dimensional architecture that is central to lens function. This information is fundamental to defining the specific conditions and stimuli needed to recapitulate developmental programs and promote regeneration of lens structure and function after cataract surgery.


Assuntos
Opacificação da Cápsula/fisiopatologia , Transição Epitelial-Mesenquimal/fisiologia , Fibrose/fisiopatologia , Peptídeos e Proteínas de Sinalização Intracelular/fisiologia , Cristalino/fisiopatologia , Transdução de Sinais/fisiologia , Fator de Crescimento Transformador beta/fisiologia , Extração de Catarata/efeitos adversos , Diferenciação Celular , Proliferação de Células , Humanos , Cristalino/metabolismo , Sistema de Sinalização das MAP Quinases/fisiologia , Receptores Proteína Tirosina Quinases/metabolismo , Via de Sinalização Wnt/fisiologia
13.
Klin Oczna ; 118(3): 191-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-30088382

RESUMO

The aim: To evaluate the effect of selected perioperative factors and concomitant diseases on glistening of acrylic hydrophobic intraocular lens after phacoemulsification in a prospective study. Material and methods: 252 consecutive patients undergoing phacoemulsification with IOLs AcrySof IQ implantation were enrolled. The relationship between glistening and such factors as time of the surgery, the mean power and time of ultrasound energy, temperature of infusion fluids, type of cartridge, mean power of intraocular lens, trypan blue staining as well as some concomitant systemic and local diseases were analysed. The aforementioned factors were assessed a month 1. and 6. as well as after 1 and 2 years postoperatively. Results: Glistening incidence and severity increased significantly at each follow up. The use of cartridge D during intraocular lens implantation was related with significantly higher incidence of glistening as compared to using cartridge C. Higher refractive power of intraocular lens was related with increased incidence of glistening. Significantly higher intensity of the glistening was assessed in patients who suffered from diabetes. In turn, patients with uveitis presented with statistically lower severity of glistening. There was no association between other analysed factors and glistening. Conclusion: Glistening commonly occurs in patients after phacoemulsification and acrylic hydrophobic intraocular lenses (AcrySof Alcon Labs) implantation. Some intraoperative factors such as refractive power of the lens and smaller diameter of the cartridge were assessed to be significantly correlated. It might indicate that potential damage to the intraocular lens may play a role in development of glistening. Significantly higher severity of glistening was shown in patients with diabetes, which may imply the role of breakdown of physiological intraocular barriers. It is further supported by the demonstrated lower intensity of glistening in patients uveitis receiving high intensity steroid therapy.


Assuntos
Resinas Acrílicas/efeitos adversos , Interações Hidrofóbicas e Hidrofílicas , Implante de Lente Intraocular/efeitos adversos , Lentes Intraoculares/efeitos adversos , Acuidade Visual/fisiologia , Adulto , Opacificação da Cápsula/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
14.
Br J Ophthalmol ; 99(8): 1137-42, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25829488

RESUMO

PURPOSE: We define the ideal anterior capsulotomy through consideration of capsular histology and biomechanics. Desirable qualities include preventing posterior capsular opacification (PCO), maintaining effective lens position (ELP) and optimising capsular strength. METHODS: Laboratory study of capsular biomechanics and literature review of histology and published clinical results. RESULTS: Parameters of ideal capsulotomy construction include complete overlap of the intraocular lens to prevent PCO, centration on the clinical approximation of the optical axis of the lens to ensure concentricity with the capsule equator, and maximal capsular thickness at the capsulotomy edge to maintain integrity. CONCLUSIONS: Constructing the capsulotomy centred on the clinical approximation of the optical axis of the lens with diameter 5.25 mm optimises prevention of PCO, consistency of ELP and capsular strength.


Assuntos
Cápsula Anterior do Cristalino/cirurgia , Opacificação da Cápsula/prevenção & controle , Capsulorrexe/métodos , Terapia a Laser/métodos , Animais , Fenômenos Biomecânicos , Opacificação da Cápsula/fisiopatologia , Cápsula do Cristalino/fisiopatologia , Suínos , Resistência à Tração
15.
Exp Eye Res ; 134: 148-54, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25704214

RESUMO

Accommodation may be restored to presbyopic lenses by refilling the lens capsular bag with a soft polymer. After this accommodative lens refilling prevention of capsular opacification is a requirement, since capsular opacification leads to a decreased clarity of the refilled lens. It has been hypothesized that capsular fibrosis causing the capsular opacification results in increased stiffness of the lens capsular bag, therewith contributing to a decrease in accommodative amplitude of the lens. However, the change in viscoelastic properties of refilled lenses due to capsular fibrosis has never been measured directly. In this study we examined natural lenses from enucleated porcine eyes and refilled lenses directly after refilling and after three months of culturing, when capsular fibrosis had developed, and determined their viscoelastic properties with a low load compression tester. Control refilled lenses were included in which capsular opacification was prevented by treatment with actinomycin D. We related lens stiffening to the degree of capsular opacification, as derived from the microscopic images taken with a confocal laser scanning microscope. Overall, the refilled lenses directly after refilling were softer than refilled lenses after three months of culturing, and refilled lenses treated with actinomycin D were softer compared with untreated refilled lenses. The degree of capsular opacification as assessed by microscopy corresponds to an increase in lens stiffness. This indicates that the viscoelastic properties of the refilled lens are influenced by capsular fibrosis and modulated by treatment of the lens epithelium. In conclusion, this study shows that the development of capsular fibrosis negatively affects the viscoelastic properties of isolated, cultured refilled lenses.


Assuntos
Acomodação Ocular , Opacificação da Cápsula/fisiopatologia , Elasticidade/fisiologia , Cristalino/fisiologia , Cápsula Posterior do Cristalino/efeitos dos fármacos , Elastômeros de Silicone/administração & dosagem , Animais , Opacificação da Cápsula/etiologia , Opacificação da Cápsula/prevenção & controle , Capsulorrexe , Dactinomicina/farmacologia , Modelos Animais de Doenças , Técnicas de Imagem por Elasticidade , Fibrose , Técnicas de Cultura de Órgãos , Cápsula Posterior do Cristalino/patologia , Inibidores da Síntese de Proteínas/farmacologia , Sus scrofa
16.
J Cataract Refract Surg ; 41(1): 90-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25454363

RESUMO

PURPOSE: To compare parameters after 1-piece and 3-piece intraocular lens (IOL) implantation. SETTING: Moorfields West End Clinic, London, United Kingdom, and Hanusch Hospital, Vienna, Austria. DESIGN: Prospective randomized controlled trial. METHODS: Each eye of patients having bilateral surgery for age-related cataract was randomized to have implantation of a 1-piece IOL (Tecnis ZCB00) or a 3-piece IOL (Tecnis ZA9003). Changes in visual acuity, refraction, and anterior chamber depth (ACD) were evaluated during a 2-year follow-up. Intraocular lens tilt and decentration were evaluated using a Purkinje meter. Regeneratory posterior capsule opacification (PCO) was analyzed using retroillumination photographs in Automated Quantification of After-Cataract image-analysis software. RESULTS: This study comprised 100 eyes of 50 patients. No statistically significant differences were found in IOL tilt or decentration between groups (P≥.06). Minimal but statistically significant changes were observed in the vertical tilt component 12 months postoperatively in the 3-piece IOL group (P<.01). The tilt and decentration components did not correlate with changes in sphere or the regeneratory PCO score (r = 0.38, P≥.06). The ACD decreased significantly between 1 day and 1 month postoperatively in both groups (P<.01), with no significant changes afterward (P≥.22). The anterior chamber was significantly deeper in the 1-piece group at all follow-up visits (P<.01). CONCLUSIONS: Both the 1-piece IOL and the 3-piece IOL showed excellent positional stability in the capsular bag, resulting in good clinical outcomes. Regeneratory PCO levels were low and comparable between the IOLs. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Opacificação da Cápsula/fisiopatologia , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Cápsula Posterior do Cristalino/fisiopatologia , Pseudofacia/fisiopatologia , Resinas Acrílicas , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/patologia , Materiais Biocompatíveis , Método Duplo-Cego , Feminino , Humanos , Interações Hidrofóbicas e Hidrofílicas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
17.
Arch Soc Esp Oftalmol ; 88(11): 415-22, 2013 Nov.
Artigo em Espanhol | MEDLINE | ID: mdl-24157319

RESUMO

OBJECTIVE: To determine the effect of posterior capsulotomy on macular thickness, intraocular pressure and endothelial cell loss in pseudophakic patients with posterior capsule opacification using the other eye of every patient as a control. METHODS: An observational prospective study was conducted on 31 pseudophakic patients with posterior capsular opacification in one eye, using the other eye as a control. Patients did not suffer any other ocular pathology. All patients were treated by posterior capsular opacification with Nd:YAG capsulotomy, and followed up for a three-month period. The ocular examination included, best corrected visual acuity (BCVA), intraocular pressure (IOP), macular optical coherence tomography (OCT), and endothelial cell assessment (including densitometry, cell size and coefficient of variation, hexagonal cell percentage and pachymetry), which were determined in both eyes before treatment, and one week, one month and 3 months after capsulotomy. RESULTS: Generalized estimating equations (GEE) were used to assess the capsulotomy effect adjusted by corresponding baseline measurements and time. No association was found between capsulotomy and IOP (P=.597), macular thickness (P=.085) or ECA (densitometry (P=.422), average size of cells (P=.299), variation coefficient (P=.495), hexagonal cell percent (P=.093) and corneal pachymetry (P=.423). A significant increase of 0.15 Snellen units in BCVA was found during the 3-month follow-up period (P<.001). CONCLUSION: This study shows that after Nd:YAG capsulotomy, BCVA improves significantly without any IOP, OCT or ECA changes during the three-month follow-up. Nd:YAG capsulotomy is a safe procedure in pseudophakic patients without any other ocular pathology.


Assuntos
Opacificação da Cápsula/cirurgia , Lasers de Estado Sólido/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Opacificação da Cápsula/etiologia , Opacificação da Cápsula/patologia , Opacificação da Cápsula/fisiopatologia , Células Endoteliais/patologia , Feminino , Fóvea Central/patologia , Humanos , Pressão Intraocular , Masculino , Neodímio , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Procedimentos Cirúrgicos Oftalmológicos/métodos , Estudos Prospectivos , Pseudofacia/complicações , Tomografia de Coerência Óptica
18.
Eye (Lond) ; 27(12): 1388-90, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24037236

RESUMO

PURPOSE: To report the incidence of anterior capsule contraction syndrome (ACCS) and to present a novel minimally invasive bimanual technique for anterior segment revision surgery associated with ACCS with anterior flexion of the intraocular lens haptics. METHODS: A consecutive cohort of 268 eyes of 161 patients undergoing phacoemulsification and implantation of the same type of hydrophilic acrylic aspheric intraocular lens cohort were analysed and a novel technique of minimally invasive bimanual technique for anterior segment revision surgery is described. RESULTS: We identified four eyes (1.5%) of three patients with advanced ACCS. Successful restoration of a clear visual axis with minimal induction of astigmatism and rapid visual rehabilitation was achieved in all four cases. CONCLUSION: This technique is a safe and minimally invasive alternative to laser or vitrector-cut capsulotomy to restore a clear visual axis. In cases of advanced ACCS, it offers the option for haptic reposition or amputation.


Assuntos
Cápsula Anterior do Cristalino/cirurgia , Opacificação da Cápsula/cirurgia , Contratura/cirurgia , Lentes Intraoculares/efeitos adversos , Facoemulsificação/efeitos adversos , Complicações Pós-Operatórias , Idoso , Cápsula Anterior do Cristalino/patologia , Opacificação da Cápsula/etiologia , Opacificação da Cápsula/fisiopatologia , Contratura/etiologia , Contratura/fisiopatologia , Fibrose , Humanos , Implante de Lente Intraocular , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Refração Ocular/fisiologia , Reoperação , Estudos Retrospectivos , Síndrome , Acuidade Visual/fisiologia
19.
J Cataract Refract Surg ; 39(7): 1107-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23809946

RESUMO

UNLABELLED: It has been suggested that a clear anterior nasal capsule contributes to negative dysphotopsia and that symptoms may resolve with opacification of the capsule. We describe a case in which negative dysphotopsia occurred despite a translucent anterior peripheral capsule and resolved following laser removal of the anterior nasal capsule. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Cápsula Anterior do Cristalino/cirurgia , Opacificação da Cápsula/fisiopatologia , Lasers de Estado Sólido/uso terapêutico , Implante de Lente Intraocular , Facoemulsificação , Complicações Pós-Operatórias , Transtornos da Visão/fisiopatologia , Idoso , Cápsula Anterior do Cristalino/patologia , Opacificação da Cápsula/etiologia , Fibrose , Humanos , Masculino , Transtornos da Visão/etiologia , Acuidade Visual/fisiologia
20.
Arch Soc Esp Oftalmol ; 88(8): 291-7, 2013 Aug.
Artigo em Espanhol | MEDLINE | ID: mdl-23886359

RESUMO

PURPOSE: To study the relationship between refraction after cataract surgery and the use of spectacles in patients older than 65 years. METHODS: Retrospective case control study. The study included 40 retired subjects older than 65 years-old who fulfilled our inclusion criteria. Clinical ophthalmic and optical information was collected, and patients were requested to complete a validated questionnaire of visual function (VF14) and a test of independence of spectacles. The difference between VF14 test results with and without glasses (difVF14) was calculated. RESULTS: The study included 16 men and 24 women, with a mean age of 74 years. There was a significant correlation between difVF14 and postoperative refraction, with lower difVF14 values associated with postsurgical refraction in the range -0.50 to -1.00 D (OD 0.479 [95% CI; 0.286-0.804]). The questionnaire of independency of lenses did not show significant correlation with postoperative refraction. CONCLUSIONS: Patients with postsurgical refraction between -0.50 and -1.00 diopters displayed better visual function without glasses than those with refraction out of that range. Neutral distant refraction and positive lenses for near vision might not be the ideal solution for every patient. Postsurgical refraction should be individualized for each patient according to their personal preferences, in order to achieve the best visual function and the best vision-related quality of life.


Assuntos
Opacificação da Cápsula/fisiopatologia , Extração de Catarata , Acuidade Visual , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Estudos Retrospectivos , Inquéritos e Questionários