Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
2.
J Cardiovasc Med (Hagerstown) ; 9(11): 1169-72, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18852597

RESUMO

We describe the case of a 30-year-old pregnant woman who underwent pacemaker implantation for recurrent syncope caused by sinus arrest. In order to minimize radiation exposure, which may potentially have teratogenic effects, we decided to perform pacemaker implantation by means of a hybrid technique involving the evaluation of electrophysiologic signals and transthoracic echocardiographic imaging to guide lead positioning within the right ventricle. After the procedure, the patient was always asymptomatic and had no recurrences of syncope. Six months later, she experienced uncomplicated natural labor, and the newborn was absolutely healthy. On a 10-month follow-up examination, the lead position was still optimal, and ventricular sensing and pacing thresholds were good. Our case demonstrates that pacemaker implantation under the guidance of electrophysiologic signals and transthoracic echocardiographic imaging, with only a short view by pulsed fluoroscopy in order to verify the correct lead position, is an effective and well-tolerated procedure in pregnant women.


Assuntos
Estimulação Cardíaca Artificial , Eletrocardiografia , Marca-Passo Artificial , Complicações Cardiovasculares na Gravidez/terapia , Parada Sinusal Cardíaca/terapia , Síncope/terapia , Ultrassonografia de Intervenção , Adulto , Feminino , Fluoroscopia/efeitos adversos , Humanos , Nascido Vivo , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem , Doses de Radiação , Recidiva , Parada Sinusal Cardíaca/complicações , Parada Sinusal Cardíaca/diagnóstico por imagem , Síncope/diagnóstico por imagem , Síncope/etiologia , Resultado do Tratamento
3.
Yonsei Med J ; 48(5): 810-7, 2007 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-17963339

RESUMO

PURPOSE: A maximum P-wave duration (Pmax) of > or = 110 msec and a P-wave dispersion (PWD) > or = 40 msec are accepted indicators of a disturbance in interatrial conduction and an inhomogeneous propagation of the sinus impulse, respectively. The left atrial (LA) volume has been reported to be strongly associated with a systolic and diastolic dysfunction and is considered to be an index of atrial remodeling. We aimed to investigate the relationship between LA volume and Pmax or PWD in patients with congestive heart failure (CHF). PATIENTS AND METHODS: Sixty-one patients with CHF were enrolled in this study. The study population was classified into four groups: two groups were divided according to the Pmax (> or = 110 msec or < 110 ms), and the other two groups were formed based on the PWD (> or = 40 msec or < 40 msec). The left atrial volume index (LAVi) was measured by three-dimensional (3-D) transthoracic echocardiography. The Pmax and PWD were measured from a 12-lead electrocardiogram. RESULTS: There were significant differences in the ejection fraction (EF), diastolic function, and LAVi between patients with a Pmax > or = 110 ms or a PWD > or = 40 ms and those with a Pmax < 110 ms or a PWD < 40 ms. The LAVi was independently associated with a disturbance in interatrial conduction and an inhomogeneous propagation of the sinus impulse. The LAVi can be used to identify patients with a disturbance in interatrial conduction and an inhomogeneous propagation of the sinus impulse with reasonably good accuracy. CONCLUSION: We concluded that a disturbance in interatrial conduction and an inhomogeneous propagation of the sinus impulse in patients with CHF is associated with an increase in the LA volume and a deleterious systolic and diastolic dysfunction.


Assuntos
Função do Átrio Esquerdo , Volume Cardíaco , Eletrocardiografia , Insuficiência Cardíaca/fisiopatologia , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Parada Sinusal Cardíaca/diagnóstico por imagem
4.
Yonsei Medical Journal ; : 810-817, 2007.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-175319

RESUMO

PURPOSE: A maximum P-wave duration (Pmax) of > or = 110msec and a P-wave dispersion (PWD) > or = 40msec are accepted indicators of a disturbance in interatrial conduction and an inhomogeneous propagation of the sinus impulse, respectively. The left atrial (LA) volume has been reported to be strongly associated with a systolic and diastolic dysfunction and is considered to be an index of atrial remodeling. We aimed to investigate the relationship between LA volume and Pmax or PWD in patients with congestive heart failure (CHF). PATIENTS AND METHODS: Sixty-one patients with CHF were enrolled in this study. The study population was classified into four groups: two groups were divided according to the Pmax (> or = 110msec or or = 40msec or or = 110ms or a PWD > or = 40ms and those with a Pmax < 110ms or a PWD < 40ms. The LAVi was independently associated with a disturbance in interatrial conduction and an inhomogeneous propagation of the sinus impulse. The LAVi can be used to identify patients with a disturbance in interatrial conduction and an inhomogeneous propagation of the sinus impulse with reasonably good accuracy. CONCLUSION: We concluded that a disturbance in interatrial conduction and an inhomogenous propagation of the sinus impulse in patients with CHF is associated with an increase in the LA volume and a deleterious systolic and diastolic dysfunction.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Função do Átrio Esquerdo , Volume Cardíaco , Ecocardiografia , Eletrocardiografia , Insuficiência Cardíaca/fisiopatologia , Parada Sinusal Cardíaca/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...