Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 64(2): 125-129, mar.-abr. 2020. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-196241

RESUMO

El tratamiento retentivo de material protésico sobreinfectado por gérmenes resistentes es un desafío, especialmente cuando el agente causal es Staphylococcus aureus resistente a meticilina. Presentamos el manejo conservador satisfactorio de material de osteosíntesis implantado por fractura de tobillo a un paciente añoso y que sufrió sobreinfección por el citado microorganismo, en el que el tratamiento antimicrobiano consistió en la combinación de antibioterapia sistémica guiada por antibiograma (tras un primer ciclo empírico ineficaz), junto a irrigaciones tópicas de sevoflurano, aplicación de crema de sulfadiazina de plata y posteriormente cobertura del defecto cutáneo con terapia de presión negativa. Destacamos el novedoso papel del sevoflurano como analgésico y como antimicrobiano tópico (sumado a la crema de sulfadiazina de plata) en la evolución favorable de la herida, especialmente en el período en el que la antibioterapia empírica era ineficaz y todavía no se había comenzado con terapia de presión negativa


Retentive treatment of prosthetic material superinfected by resistant microorganisms is a challenge, especially when the causative agent is a methicillin-resistant Staphylococcus aureus. We present the successful conservative management of osteosynthesis material implanted due to ankle fracture in an elderly patient who suffered superinfection by the aforementioned microorganism, in which the antimicrobial treatment consisted of the combination of antibiotic-guided systemic antibiotics (after a first ineffective empirical cycle), together with topical irrigations of sevoflurane, applications of silver sulfadiazine cream, and subsequently coverage of the skin defect with negative pressure therapy. We highlight the novel role of sevoflurane as an analgesic and as a topical antimicrobial agent (in addition to silver sulfadiazine) in the favourable evolution of the wound, especially in the period in which the empirical antibiotic therapy was ineffective and negative pressure therapy had not yet been applied


Assuntos
Humanos , Masculino , Idoso de 80 Anos ou mais , Placas Ósseas/efeitos adversos , Tratamento Conservador/métodos , Staphylococcus aureus Resistente à Meticilina , Infecções Relacionadas à Prótese/terapia , Infecções Estafilocócicas/terapia , Superinfecção/terapia , Infecção da Ferida Cirúrgica/terapia , Placas Ósseas/microbiologia , Coinfecção/diagnóstico , Coinfecção/microbiologia , Coinfecção/terapia , Terapia Combinada , Fixação Interna de Fraturas/instrumentação , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Superinfecção/diagnóstico , Superinfecção/microbiologia , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/microbiologia
2.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31892471

RESUMO

Retentive treatment of prosthetic material superinfected by resistant microorganisms is a challenge, especially when the causative agent is a methicillin-resistant Staphylococcus aureus. We present the successful conservative management of osteosynthesis material implanted due to ankle fracture in an elderly patient who suffered superinfection by the aforementioned microorganism, in which the antimicrobial treatment consisted of the combination of antibiotic-guided systemic antibiotics (after a first ineffective empirical cycle), together with topical irrigations of sevoflurane, applications of silver sulfadiazine cream, and subsequently coverage of the skin defect with negative pressure therapy. We highlight the novel role of sevoflurane as an analgesic and as a topical antimicrobial agent (in addition to silver sulfadiazine) in the favourable evolution of the wound, especially in the period in which the empirical antibiotic therapy was ineffective and negative pressure therapy had not yet been applied.


Assuntos
Placas Ósseas/efeitos adversos , Tratamento Conservador/métodos , Staphylococcus aureus Resistente à Meticilina , Infecções Relacionadas à Prótese/terapia , Infecções Estafilocócicas/terapia , Superinfecção/terapia , Infecção da Ferida Cirúrgica/terapia , Idoso de 80 Anos ou mais , Placas Ósseas/microbiologia , Coinfecção/diagnóstico , Coinfecção/microbiologia , Coinfecção/terapia , Terapia Combinada , Fixação Interna de Fraturas/instrumentação , Humanos , Masculino , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Superinfecção/diagnóstico , Superinfecção/microbiologia , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/microbiologia
3.
J Med Case Rep ; 13(1): 129, 2019 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-31036083

RESUMO

INTRODUCTION: Pharyngoesophageal diverticulum is an uncommon complication after anterior cervical discectomy and fusion surgery. CASE PRESENTATION: Our patient was a 48-year-old woman with two previous cervical surgeries with fixation of C4-C5 and C5-C6, the last one in 2003. Two years after surgery, she presented with arthralgia, arthritis, chills, and fluctuating rash. In 2007, she presented with dysphagia, halitosis, and sputum production. She was diagnosed with a pharyngoesophageal diverticulum with a fistula to C6 vertebra and secondary spondylitis. She was taken for open surgery with removal of screws and plates, cricopharyngeal myotomy, and esophageal repair. Streptococcus milleri grew in tissue and osteosynthetic material. She received 4 months of amoxicillin and probenecid and had a complete recovery. Since 1991, 19 similar cases have been reported with one fatality. To our knowledge, this is the first reported case of diverticulum complicated with fistula and secondary spondylitis. CONCLUSIONS: In patients with a history of anterior cervical discectomy and fusion complaining of dysphagia, even years after surgery, it is mandatory to perform an esophagogram. This symptom was referred to in 88% of the cases reported in the literature.


Assuntos
Remoção de Dispositivo , Diverticulite/diagnóstico por imagem , Complicações Pós-Operatórias/patologia , Fusão Vertebral/efeitos adversos , Espondilite/diagnóstico por imagem , Infecções Estreptocócicas/diagnóstico , Adjuvantes Farmacêuticos , Amoxicilina , Placas Ósseas/microbiologia , Parafusos Ósseos/microbiologia , Transtornos de Deglutição/diagnóstico por imagem , Diverticulite/terapia , Feminino , Humanos , Pessoa de Meia-Idade , Miotomia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Probenecid , Radiografia , Espondilite/terapia , Infecções Estreptocócicas/tratamento farmacológico , Streptococcus milleri (Grupo)/isolamento & purificação , Resultado do Tratamento
4.
BMC Musculoskelet Disord ; 19(1): 260, 2018 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-30049271

RESUMO

BACKGROUND: Orthopaedic implant infections are difficult to eradicate because bacteria adhering to implant surfaces inhibit the ability of the immune system and antibiotics to combat these infections. Thermal cycling is a temperature modulation process that improves performance and longevity of materials through molecular structural reorientation, thereby increasing surface uniformity. Thermal cycling may change material surface properties that reduce the ability for bacteria to adhere to the surface of orthopaedic implants. This study aims to determine whether thermal cycling of orthopaedic implants can reduce bacterial growth. METHODS: In a randomized, blinded in-vitro study, titanium and stainless steel plates treated with thermal cycling were compared to controls. Twenty-seven treated and twenty-seven untreated plates were covered with 10 ml tryptic soy broth containing ~ 105 colony forming units (CFU)/ml of bioluminescent Staphylococcus aureus (S. aureus)Xen29 and incubated at 37 °C for 14d. Quantity and viability of bacteria were characterized using bioluminescence imaging, live/dead staining and determination of CFUs. RESULTS: Significantly fewer CFUs grow on treated stainless steel plates compared to controls (p = 0.0088). Similar findings were seen in titanium plates (p = 0.0048) following removal of an outlier. No differences were evident in live/dead staining using confocal microscopy, or in metabolic activity determined using bioluminescence imaging (stainless steel plates: p = 0.70; titanium plates: p = 0.26). CONCLUSION: This study shows a reduction in CFUs formation on thermal cycled plates in-vitro. Further in-vivo studies are necessary to investigate the influence of thermal cycling on bacterial adhesion during bone healing. Thermal cycling has demonstrated improved wear and strength, with reductions in fatigue and load to failure. The added ability to reduce bacterial adhesions demonstrates another potential benefit of thermal cycling in orthopaedics, representing an opportunity to reduce complications following fracture fixation or arthroplasty.


Assuntos
Biofilmes/crescimento & desenvolvimento , Placas Ósseas/microbiologia , Temperatura Alta/uso terapêutico , Aço Inoxidável , Staphylococcus aureus/fisiologia , Titânio , Humanos , Procedimentos Ortopédicos/instrumentação , Estudo de Prova de Conceito , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/terapia , Distribuição Aleatória , Método Simples-Cego
5.
Acta Orthop ; 89(5): 580-584, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29947288

RESUMO

Background and purpose - Cutibacterium acnes, formerly known as Propionibacterium acnes, is often isolated from deep tissues of the shoulder. It is recognized as an important causative agent of foreign-material associated infections. However, the incidence and significance of its detection in tissues from patients without clinical evidence for infection is unclear. We assessed the incidence of C. acnes colonization of osteosynthesis material in asymptomatic patients, and evaluated the short-term outcome in relation to the microbiological findings. Patients and methods - We microbiologically analyzed osteosynthesis material of 34 asymptomatic patients after surgery on the clavicle. Material obtained from 19 asymptomatic patients after osteosynthesis of the fibula served as a control group. Patients were clinically followed up for 3-24 months after removal of the osteosynthesis material. Results - Bacteria were recovered from devices in 29 of 34 patients from the clavicle group. 27 of 29 positive samples grew C. acnes. Isolation of C. acnes was more common in male than in female patients. No bacterial growth was observed on foreign material from patients in the fibula group. All patients remained asymptomatic at follow-up. Interpretation - Growth of C. acnes is common on osteosynthesis material of the shoulder, especially in males. Samples were positive irrespective of clinical signs of infection. Therefore, detection of C. acnes in this clinical setting is of questionable clinical significance. The high positivity rate in asymptomatic patients discourages routine sampling of material in cases without clinical evidence for infection.


Assuntos
Placas Ósseas/microbiologia , Fixação Interna de Fraturas/instrumentação , Propionibacterium acnes/isolamento & purificação , Fraturas do Ombro/cirurgia , Articulação do Ombro/microbiologia , Adulto , Idoso , Parafusos Ósseos/microbiologia , Clavícula/lesões , Clavícula/cirurgia , Remoção de Dispositivo , Contaminação de Equipamentos , Feminino , Fíbula/lesões , Fíbula/cirurgia , Seguimentos , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Propionibacterium acnes/crescimento & desenvolvimento , Articulação do Ombro/cirurgia , Adulto Jovem
6.
Int J Pharm ; 547(1-2): 235-243, 2018 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-29864515

RESUMO

The major clinical hindrance of orthopedic implants is the bacterial infection, which can lead to biofilm formation and ultimately results in implant rejection. In this research, layer-by-layer nanocoating consists of vancomycin/PLA/vancomycin-loaded niosomes was designed. Vancomycin-loaded niosomes were formulated by thin film hydration method and the attributes of niosomes in terms of size, zeta potential, drug loading and EE, were assessed. The size was 340.5 ±â€¯2.95 nm with the zeta potential and %EE was 45.4 ±â€¯0.77 mV and 50.47 ±â€¯3.66% respectively. The dip coating technique was used to deposit a thin film, which was characterized morphologically under FE-SEM. Drug release from coated bone plates with and without vancomycin-loaded niosomes was also studied and results suggested that bone plates coated with vancomycin-loaded niosomes have accumulated more vancomycin than the control group and hence aided in the prolonged release up to two weeks. These niosomes-coated bone plates demonstrated superior antibacterial activity for longer time period, without exhibiting any cytotoxic effects towards normal cells (L929). These findings offer a promising approach to control the bacterial colonization and biofilms formation. This thin film nano-coating can also be utilized in coating of other medical devices, which are prone to infections.


Assuntos
Antibacterianos/administração & dosagem , Desenho de Prótese , Infecções Relacionadas à Prótese/prevenção & controle , Vancomicina/administração & dosagem , Animais , Antibacterianos/farmacologia , Antibacterianos/toxicidade , Biofilmes/efeitos dos fármacos , Placas Ósseas/microbiologia , Linhagem Celular , Preparações de Ação Retardada , Liberação Controlada de Fármacos , Lipossomos , Camundongos , Poliésteres/química , Próteses e Implantes/microbiologia , Vancomicina/farmacologia , Vancomicina/toxicidade
7.
BMC Res Notes ; 10(1): 635, 2017 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-29183358

RESUMO

BACKGROUND: The aim of this study is to establish the bacterial epidemiology of chronic osteoarticular infections in adults, to study the susceptibility of the isolated strains to antibiotics and to demonstrate the influence of osteosynthesis material thereon. PATIENTS AND METHODS: This is a retrospective study of 78 months, from January 2006 to June 2012, providing bacteriological samples from patients with osteitis and osteoarthritis in the Mohammed V military teaching hospital of Rabat. Isolation and identification of bacteria were made by bacteriological classical techniques. The antimicrobial susceptibility testing of the isolates was performed by disk diffusion agar method, as recommended by the Committee of the susceptibility of the French Society for Microbiology (CA-SFM). RESULTS: We collected 234 cases, 53% (n = 124) of patients without osteosynthesis material (group A) and 47% (n = 110) patients with osteosynthesis material (group B).We isolated 371 bacteria which 51.49 (n = 191) in group A and 48.51% (n = 180) in group B. Gram-positive cocci were the most frequent (n = 234), followed by the Gram-negative bacilli (n = 114) and the Gram-positive bacilli (n = 19). Our study shows that the rate of resistance to antibiotics in strains obtained from patients with osteosynthesis material is higher compared to those obtained from patients without osteosynthesis material. CONCLUSIONS: Chronic OA infection in adults is difficult to diagnose and treat. Its good management must be multidisciplinary.


Assuntos
Doenças Ósseas Infecciosas/microbiologia , Farmacorresistência Bacteriana , Bactérias Gram-Negativas/isolamento & purificação , Bactérias Gram-Positivas/isolamento & purificação , Fixadores Internos/microbiologia , Osteíte/microbiologia , Osteoartrite/microbiologia , Adulto , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Doenças Ósseas Infecciosas/tratamento farmacológico , Doenças Ósseas Infecciosas/epidemiologia , Pinos Ortopédicos/microbiologia , Placas Ósseas/microbiologia , Parafusos Ósseos/microbiologia , Doença Crônica , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão , Bactérias Gram-Negativas/efeitos dos fármacos , Bactérias Gram-Positivas/efeitos dos fármacos , Humanos , Osteíte/tratamento farmacológico , Osteíte/epidemiologia , Osteoartrite/tratamento farmacológico , Osteoartrite/epidemiologia , Estudos Retrospectivos
9.
Injury ; 47(3): 633-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26830128

RESUMO

INTRODUCTION: Implant-related infection is a challenging complication in musculoskeletal trauma surgery. In the present study, we examined the role of implant material and surface topography as influencing factors on the development of infection in an experimental model of plating osteosynthesis in the rabbit. METHODS: The implants included in this experimental study were composed of: standard Electropolished Stainless Steel (EPSS), standard titanium (Ti-S), roughened stainless steel (RSS) and surface polished titanium (Ti-P). Construct stability and load-to-failure of Ti-P implants was compared to that of Ti-S implants in a rabbit cadaveric model. In an in vivo study, a rabbit humeral fracture model was used. Each rabbit received one of three Staphylococcus aureus inocula, aimed at determining the infection rate at a low, medium and high dose of bacteria. Outcome measures were quantification of bacteria on the implant and in the surrounding tissues, and determination of the infectious dose 50 (ID50). RESULTS: No significant differences were observed between Ti-S and Ti-P regarding stiffness or failure load in the cadaver study. Of the 72 rabbits eventually included in the in vivo study, 50 developed an infection. The ID50 was found to be: EPSS 3.89×10(3) colony forming units (CFU); RSS 8.23×10(3) CFU; Ti-S 5.66×10(3) CFU; Ti-P 3.41×10(3) CFU. Significantly lower bacterial counts were found on the Ti-S implants samples compared with RSS implants (p<0.001) at the high inoculum. Similarly, lower bacterial counts were found in the bone samples of animals in the Ti-S group in comparison with both RSS and EPSS groups, again at the high inoculation dose (p<0.005). CONCLUSION: No significant differences were seen in susceptibility to infection when comparing titanium and steel implants with conventional or modified topographies. Ti-P implants, which have previously been shown in preclinical studies to reduce complications associated with tissue adherence, do not affect infection rate in this preclinical fracture model. Therefore, Ti-P implants are not expected to affect the infection rate, or influence implant stability in the clinical situation.


Assuntos
Placas Ósseas , Fraturas do Úmero/cirurgia , Infecções Relacionadas à Prótese/patologia , Aço Inoxidável , Infecções Estafilocócicas/patologia , Titânio , Animais , Aderência Bacteriana , Placas Ósseas/microbiologia , Cadáver , Modelos Animais de Doenças , Feminino , Fixação Interna de Fraturas , Fraturas do Úmero/microbiologia , Fraturas do Úmero/patologia , Teste de Materiais , Infecções Relacionadas à Prótese/microbiologia , Coelhos , Infecções Estafilocócicas/microbiologia , Propriedades de Superfície
10.
Antimicrob Agents Chemother ; 58(12): 7586-91, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25288077

RESUMO

Periprosthetic infection remains a challenging clinical complication. We investigated the antibacterial properties of pure (99.9%) magnesium (Mg) in vitro and in an in vivo rat model of implant-related infection. Mg was highly effective against methicillin-resistant Staphylococcus aureus-induced osteomyelitis and improved new peri-implant bone formation. Bacterial icaA and agr RNAIII transcription levels were also assessed to characterize the mechanism underlying the antibacterial properties of the Mg implant.


Assuntos
Antibacterianos/farmacologia , Magnésio/farmacologia , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Osteomielite/tratamento farmacológico , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Estafilocócicas/tratamento farmacológico , Animais , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Densidade Óssea/efeitos dos fármacos , Placas Ósseas/microbiologia , Parafusos Ósseos/microbiologia , Modelos Animais de Doenças , Fêmur/efeitos dos fármacos , Fêmur/microbiologia , Fêmur/cirurgia , Staphylococcus aureus Resistente à Meticilina/crescimento & desenvolvimento , Testes de Sensibilidade Microbiana , Osteomielite/microbiologia , Osteomielite/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/cirurgia , Ratos , Ratos Sprague-Dawley , Infecções Estafilocócicas/microbiologia , Infecções Estafilocócicas/cirurgia , Titânio/farmacologia
11.
Plast Reconstr Surg ; 134(3): 412e-419e, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25158718

RESUMO

SUMMARY: Fracture stabilization in the diabetic patient is associated with higher complication rates, particularly infection and impaired wound healing, which can lead to major tissue damage, osteomyelitis, and higher amputation rates. With an increasing prevalence of diabetes and an aging population, the risks of infection of internal fixation devices are expected to grow. Although numerous retrospective clinical studies have identified a relationship between diabetes and infection, currently there are few animal models that have been used to investigate postoperative surgical-site infections associated with internal fixator implantation and diabetes. The authors therefore refined the protocol for inducing hyperglycemia and compared the bacterial burden in controls to pharmacologically induced type 1 diabetic rats after undergoing internal fracture plate fixation and Staphylococcus aureus surgical-site inoculation. Using an initial series of streptozotocin doses, followed by optional additional doses to reach a target blood glucose range of 300 to 600 mg/dl, the authors reliably induced diabetes in 100 percent of the rats (n = 16), in which a narrow hyperglycemic range was maintained 14 days after onset of diabetes (mean ± SEM, 466 ± 16 mg/dl; coefficient of variation, 0.15). With respect to their primary endpoint, the authors quantified a significantly higher infectious burden in inoculated diabetic animals (median, 3.2 × 10 colony-forming units/mg dry tissue) compared with inoculated nondiabetic animals (7.2 × 10 colony-forming units/mg dry tissue). These data support the authors' hypothesis that uncontrolled diabetes adversely affects the immune system's ability to clear Staphylococcus aureus associated with internal hardware.


Assuntos
Diabetes Mellitus Experimental/complicações , Diabetes Mellitus Tipo 1/complicações , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Infecções Estafilocócicas/etiologia , Staphylococcus aureus/crescimento & desenvolvimento , Infecção da Ferida Cirúrgica/etiologia , Animais , Placas Ósseas/microbiologia , Contagem de Colônia Microbiana , Diabetes Mellitus Experimental/induzido quimicamente , Diabetes Mellitus Tipo 1/induzido quimicamente , Fraturas do Fêmur/complicações , Fixação Interna de Fraturas/instrumentação , Masculino , Ratos , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/isolamento & purificação , Estreptozocina , Infecção da Ferida Cirúrgica/microbiologia
12.
J Craniomaxillofac Surg ; 42(7): e372-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24780352

RESUMO

INTRODUCTION: Between 3 and 18% of craniofacial osteosynthesis plates are removed due to chronic infection. Removal of the plate is necessary to manage the chronic infective state i.e. miniplate removal results in resolution of the infection. These observations are suggestive of a biofilm-related infection. The aim of this retrospective study was to characterise the presence of biofilm on the removed miniplates from oral and maxillofacial surgery. MATERIALS AND METHODS: A total of 12 plates and associated screws were recovered from eleven patients suffering from persistent, trauma site infection. The recovered plates plus 1 control plate were imaged using scanning electron microscopy (SEM). One recovered plate was also imaged using confocal microscopy (CM) for comparative purposes. RESULTS: Of the 12 plates, 3 (25%) demonstrated highly localised polymicrobial biofilms, five (42%) demonstrated coccal biofilms, one possessed a filamentous biofilm and one showed attached yeast. Overall, 75% of the plates and 82% of the patients exhibited evidence of biofilm to varying degrees. All of the infections resolved following removal of the plates and antibiotic treatment. CONCLUSION: Microbial biofilms can explain the clinical course of chronic infections associated with miniplates.


Assuntos
Biofilmes , Placas Ósseas/microbiologia , Infecções Relacionadas à Prótese/patologia , Infecção da Ferida Cirúrgica/patologia , Bactérias/classificação , Biofilmes/classificação , Parafusos Ósseos/microbiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Fraturas Mandibulares/cirurgia , Osteotomia Mandibular/instrumentação , Microscopia Confocal , Microscopia Eletrônica de Varredura , Miniaturização , Procedimentos Cirúrgicos Bucais/instrumentação , Osteotomia de Le Fort/instrumentação , Estudos Retrospectivos , Propriedades de Superfície , Deiscência da Ferida Operatória/microbiologia , Fraturas Zigomáticas/cirurgia
13.
Eur Spine J ; 23(4): 838-45, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24121752

RESUMO

OBJECTIVE: This study was designed to identify the presence, type and origin of bacteria adjacent to the metal implant in the infected region in a canine model of pyogenic vertebral osteomyelitis treated with single-stage anterior autogenous bone grafting and instrumentation. METHODS: Dogs with pyogenic spondylodiscitis underwent one-stage debridement, autogenous bone grafting and titanium plate instrumentation and perioperative antibiotic therapy. The implants and adjacent vertebral bones were removed surgically at various postoperative time points (4, 8, 12 and 24 weeks) for bacteria detection. Bacteria were detected from retrieved spinal implants as well as surrounding bones by culture and/or pyrosequencing methods in 17 (85%) of all 20 animals. The positive rate for bacteria presence was 45% by culture and 80% by pyrosequencing method. RESULTS: Radiological or macroscopic examination showed no signs for infection recurrence in any animal regardless of bacteria presence at the surgical site. However, organism identical with the causative bacterium for spinal infection was found in only two of nine culture-positive animals. CONCLUSION: Within the confines of the study, the use of metallic implants in an infected area did not lead to a clinically relevant infection although bacteria may exist at the surgical site. The use of metallic implants in an infected area of the spine is safe. The metallic implants may not be the "culprit" for the persistence or recurrence of infection.


Assuntos
Placas Ósseas/microbiologia , Transplante Ósseo/métodos , Desbridamento/métodos , Discite/cirurgia , Osteomielite/cirurgia , Fusão Vertebral/métodos , Infecções Estafilocócicas/cirurgia , Animais , Discite/microbiologia , Modelos Animais de Doenças , Cães , Escherichia coli/isolamento & purificação , Masculino , Osteomielite/microbiologia , Recidiva , Fusão Vertebral/instrumentação , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/isolamento & purificação , Staphylococcus haemolyticus/isolamento & purificação , Streptococcus agalactiae/isolamento & purificação , Titânio , Transplante Autólogo
14.
Int Orthop ; 37(11): 2253-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24052163

RESUMO

PURPOSE: In contrast to a large amount of epidemiological data regarding the incidence of implant infections after fracture management, surprisingly few have been published concerning the success of their treatment. METHODS: This was a single-centre cohort study at Geneva University Hospitals from 2000 to 2012 investigating the remission rates of orthopaedic implant infections after fracture repair and associated variables. RESULTS: A total of 139 episodes were included: There were 51 women (37%) and 28 immunosuppressed (20%) patients with a median age and American Society of Anaesthesiologists (ASA) score of 51 years and 2 points, respectively. The infected implants were plates (n = 75, 54 %), nails (24, 17%), wires (20), screws (10), cerclage cables or wires (3), hip screws (4) or material for spondylodesis (3). A pathogen was identified in 135 (97%) cases, including Staphylococcus aureus (73, 52%), coagulase-negative staphylococci (20), streptococci (7) and 19 Gram-negative rods. All patients underwent antibiotic treatment, and 128 (92%) remained in remission at a median follow-up time of 2.6 years (range one to 13 years). In multivariate logistic regression analysis, the plate infections were significantly associated with lower remission rates [65/75, 87%, odds ratio (OR) 0.1, 95% confidence interval (CI) 0.01-0.90]. No associations were found for gender, age, immune status, ASA score, additional surgical interventions (OR 0.4, 95% CI 0.1-4.1) or duration of antibiotic treatment (OR 1.0, 95% CI 0.98-1.01). CONCLUSIONS: Among all infected and removed orthopaedic implants, plates were associated with slightly lower remission rates, while the overall treatment success exceeded 90%. The duration of antibiotic therapy did not alter the outcome.


Assuntos
Infecções Bacterianas/tratamento farmacológico , Infecções Bacterianas/epidemiologia , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Fixadores Internos/microbiologia , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/terapia , Adulto , Idoso , Antibacterianos/uso terapêutico , Pinos Ortopédicos/efeitos adversos , Pinos Ortopédicos/microbiologia , Placas Ósseas/efeitos adversos , Placas Ósseas/microbiologia , Parafusos Ósseos/efeitos adversos , Parafusos Ósseos/microbiologia , Fios Ortopédicos/efeitos adversos , Fios Ortopédicos/microbiologia , Estudos de Coortes , Feminino , Seguimentos , Fixação Interna de Fraturas/métodos , Humanos , Incidência , Fixadores Internos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Indução de Remissão , Reoperação , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/microbiologia , Resultado do Tratamento
15.
J Biomed Mater Res B Appl Biomater ; 101(6): 1078-89, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23559470

RESUMO

Biofilm implant-related infections cost the US healthcare system billions of dollars each year. For several decades, device coatings have been developed that actively release antimicrobial compounds in an attempt to prevent these infections from developing. To date, few coatings have been put into clinical use. These have shown limited to no efficacy in clinical trials. Recent data have shown the in vitro and in vivo efficacy of a novel active release coating that may address the limitations of coatings that are used clinically. In this study, the novel active release coating was characterized to gain an understanding of the effects of combining an antimicrobial additive, cationic steroid antimicrobial-13 (CSA-13), to a medical grade polydimethylsiloxane (PDMS) material. Results indicated that the addition of CSA-13 did influence the physical properties of the PDMS, but not with adverse effects to the desired material properties. Furthermore, there was no indication of chemical reactivity. It was shown that CSA-13 was uniformly dispersed as small particles throughout the PDMS matrix. These particles were able to dissolve and elute out of the PDMS within a 30-day period. The results of this work suggested that the PDMS with CSA-13 was thermally, chemically and physically stable when used as a device coating to treat local infection and/or prevent biofilm implant-related infections from developing.


Assuntos
Anti-Infecciosos/administração & dosagem , Anti-Infecciosos/química , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Materiais Revestidos Biocompatíveis/química , Infecções Relacionadas à Prótese/prevenção & controle , Placas Ósseas/efeitos adversos , Placas Ósseas/microbiologia , Dimetilpolisiloxanos/química , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Espectroscopia de Infravermelho com Transformada de Fourier , Esteroides/administração & dosagem , Esteroides/química , Propriedades de Superfície , Resistência à Tração , Termogravimetria
16.
Acta Odontol Scand ; 71(1): 168-74, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22299831

RESUMO

OBJECTIVE: To fabricate the antibiotic-releasing coatings on TiO(2) nanotube surfaces for wide applications of implant and bone plate in medical and dental surgery, the optimal deposition time of amoxicillin/PLGA solution simultaneously performing non-toxicity and a high bactericidal effect for preventing early implant failures was found. MATERIALS AND METHODS: FE-SEM, ESD and FT-IR were used for confirming deposition of amoxicillin/PLGA on the TiO(2) surface. Also, the elution of amoxicillin/PLGA in a TiO(2) nanotube surface was measured by a UV-VIS spectrophotometer. The bactericidal effect of amoxicillin on the TiO(2) nanotube surface was evaluated by using Staphylococcus aureus (S. aureus). The cytotoxicity and cell proliferation were observed by WST assay using MC3T3-E1 osteoblast cells. RESULTS: The results indicated that the TiO(2) nanotube surface controlled by electro-spray deposition time with amoxicillin/PLGA solution could provide a high bactericidal effect against S. aureus by the bactericidal effect of amoxicillin, as well as good osteoblast cell proliferation at the TiO(2) nanotube surface without toxicity. CONCLUSIONS: This study used electro-spray deposition (ESD) methodology to obtain amoxicillin deposition in nanotube structures of TiO(2) and found the optimal deposition time of amoxicillin/PLGA solution simultaneously performing non-toxicity and a high bactericidal effect for preventing early implant failures.


Assuntos
Amoxicilina/administração & dosagem , Antibacterianos/administração & dosagem , Materiais Revestidos Biocompatíveis/administração & dosagem , Implantação Dentária Endóssea/métodos , Implantes Dentários , Ácido Láctico/administração & dosagem , Ácido Poliglicólico/administração & dosagem , Infecções Estafilocócicas/prevenção & controle , Células 3T3 , Amoxicilina/análise , Animais , Antibacterianos/análise , Placas Ósseas/microbiologia , Adesão Celular , Proliferação de Células , Materiais Revestidos Biocompatíveis/análise , Implantes Dentários/microbiologia , Combinação de Medicamentos , Ácido Láctico/análise , Camundongos , Nanotubos , Osteoblastos , Ácido Poliglicólico/análise , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Espectrofotometria , Espectroscopia de Infravermelho com Transformada de Fourier , Staphylococcus aureus/efeitos dos fármacos , Propriedades de Superfície , Titânio
17.
Osteoporos Int ; 24(5): 1765-6, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23229469

RESUMO

We report a case of an 86-year-old woman with an atypical femoral fracture (AFF) who was treated with intramedullary nailing followed by lateral femoral plating. She developed a second femoral shaft fracture distal to the intramedullary nail which required a second operation. Biopsy of the periosteum overlying the site of the initial proximal AFF was sent for pathogen analysis. Using the Ibis T5000 platform and the BAC plate assay, a polymicrobial infection was diagnosed consisting of Bifidobacterium subtile and Pseudomonas mendocina. This raises the possibility that bacterial infections may play some role in atypical fractures of the femur.


Assuntos
Bifidobacterium/fisiologia , Biofilmes , Conservadores da Densidade Óssea/efeitos adversos , Fraturas do Fêmur/etiologia , Pseudomonas mendocina/fisiologia , Idoso de 80 Anos ou mais , Alendronato/efeitos adversos , Infecções por Bifidobacteriales/complicações , Placas Ósseas/microbiologia , Feminino , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas , Humanos , Infecções Relacionadas à Prótese/complicações , Infecções por Pseudomonas/complicações
18.
Injury ; 44(2): 249-52, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23200030

RESUMO

BACKGROUND: Fractures of the tibial plateau present a treatment challenge and are susceptible to both prolonged operative times and high postoperative infection rates. For those fractures treated with open plating, we sought to identify the relationship between surgical site infection and prolonged operative time as well as to identify other surgical risk factors. METHODS: We performed a retrospective controlled analysis of 309 consecutive unicondylar and bicondylar tibial plateau fractures treated with open plate osteosynthesis at our institution's level I trauma centre during a recent 5-year period. We recorded operative times, injury characteristics, surgical treatment, and need for operative debridement due to infection. Operative times of infected cases were compared to uncomplicated surgical cases. Multivariable logistic regression analysis was performed to identify independent risk factors for postoperative infection. RESULTS: Mean operative time in the infection group was 2.8h vs. 2.2h in the non-infected group (p=0.005). 15 fractures (4.9%) underwent four compartment fasciotomies as part of their treatment, with a significantly higher infection rate than those not undergoing fasciotomy (26.7% vs. 6.8%, p=0.01). Open fracture grade was also significantly related to infection rate (closed fractures: 5.3%, grade 1: 14.3%, grade 2: 40%, grade 3: 50%, p<0.0001). In the bicolumnar fracture group, use of dual-incision medial and lateral plating as compared to single incision lateral locked plating had statistically similar infection rates (13.9% vs. 8.7%, p=0.36). Multivariable logistic regression analysis of the entire study group identified longer operative times (OR 1.78, p=0.013) and open fractures (OR 7.02, p<0.001) as independent predictors of surgical site infection. CONCLUSIONS: Operative times approaching 3h and open fractures are related to an increased overall risk for surgical site infection after open plating of the tibial plateau. Dual incision approaches with bicolumnar plating do not appear to expose the patient to increased risk compared to single incision approaches.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Expostas/cirurgia , Duração da Cirurgia , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Fraturas da Tíbia/cirurgia , Placas Ósseas/microbiologia , Desbridamento , Feminino , Fixação Interna de Fraturas/efeitos adversos , Fraturas Expostas/complicações , Fraturas Expostas/microbiologia , Humanos , Incidência , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Fatores de Risco , Fraturas da Tíbia/complicações , Fraturas da Tíbia/microbiologia , Resultado do Tratamento
19.
J Orthop Res ; 30(9): 1384-90, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22354694

RESUMO

Colonization of implant surfaces with bacteria should ideally be prevented right from implantation, as bacteria attaching to the surface will form a biofilm, being then well protected against antibiotic treatment. Therefore, implant coatings should combine antibacterial properties with biocompatibility towards their host tissue. We tested a UV-induced covalent coating procedure with eicosapentaenoic acid (EPA) for smooth titanium (Ti) surfaces for its ability to prevent attachment and proliferation of Staphylococcus epidermidis and to allow mineralization of MC3T3-E1 osteoblasts. Bacterial initial attachment was highest for EPA-coated surfaces, but was reduced by vigorous washing, possibly due to low adhesive strength on those surfaces. We found an increase in the ratio of dead bacteria and in overall biofilm after 16 h on Ti surfaces with covalently bound EPA compared to Ti. The UV-induced EPA coating did not impair the ability of MC3T3-E1 preosteoblasts to mineralize, while a reduction in mineralization could be found for UV-irradiated Ti surfaces and UV-irradiated surfaces washed with ethanol compared to Ti. Although in vivo studies are needed to evaluate the clinical significance, our results indicate that covalent coating of Ti surfaces with EPA by UV irradiation decreases the survival of S. epidermidis and maintains the mineralization ability of osteoblasts.


Assuntos
Biofilmes , Placas Ósseas/microbiologia , Ácido Eicosapentaenoico/administração & dosagem , Staphylococcus epidermidis/efeitos dos fármacos , Titânio/química , Células 3T3 , Animais , Calcificação Fisiológica/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Ácido Eicosapentaenoico/química , Camundongos , Osteoblastos/efeitos dos fármacos , Raios Ultravioleta , Molhabilidade
20.
Ann Thorac Surg ; 92(2): 718-20, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21801927

RESUMO

Sternal wound infections can result in significant morbidity and mortality. Managing these complications is particularly challenging when infected hardware is involved. Traditional thinking mandates removal of infected hardware, yet this hardware is often essential to chest wall stability in the early postoperative period. Here, we present a case of an infected transverse sternotomy wound involving hardware in a lung transplant patient whose treatment included successful hardware preservation. Our experience and other experiences reported in the literature highlight the alternatives in the management of this complication.


Assuntos
Placas Ósseas/microbiologia , Parafusos Ósseos/microbiologia , Desbridamento/métodos , Fibrose Pulmonar Idiopática/cirurgia , Transplante de Pulmão/instrumentação , Infecções Estafilocócicas/cirurgia , Esternotomia/instrumentação , Infecção da Ferida Cirúrgica/cirurgia , Técnicas de Fechamento de Ferimentos/instrumentação , Acetamidas/administração & dosagem , Antibacterianos/administração & dosagem , Daptomicina/administração & dosagem , Humanos , Infusões Intravenosas , Linezolida , Masculino , Pessoa de Meia-Idade , Tratamento de Ferimentos com Pressão Negativa , Oxazolidinonas/administração & dosagem , Cuidados Pós-Operatórios , Infecções Estafilocócicas/microbiologia , Infecção da Ferida Cirúrgica/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...