Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Biomolecules ; 11(10)2021 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-34680169

RESUMO

Scanning Electron Microscopy (SEM) is a powerful, high-resolution imaging technique widely used to analyze the structure of fibrin networks. Currently, structural features, such as fiber diameter, length, density, and porosity, are mostly analyzed manually, which is tedious and may introduce user bias. A reliable, automated structural image analysis method would mitigate these drawbacks. We evaluated the performance of DiameterJ (an ImageJ plug-in) for analyzing fibrin fiber diameter by comparing automated DiameterJ outputs with manual diameter measurements in four SEM data sets with different imaging parameters. We also investigated correlations between biophysical fibrin clot properties and diameter, and between clot permeability and DiameterJ-determined clot porosity. Several of the 24 DiameterJ algorithms returned diameter values that highly correlated with and closely matched the values of the manual measurements. However, optimal performance was dependent on the pixel size of the images-best results were obtained for images with a pixel size of 8-10 nm (13-16 pixels/fiber). Larger or smaller pixels resulted in an over- or underestimation of diameter values, respectively. The correlation between clot permeability and DiameterJ-determined clot porosity was modest, likely because it is difficult to establish the correct image depth of field in this analysis. In conclusion, several DiameterJ algorithms (M6, M5, T3) perform well for diameter determination from SEM images, given the appropriate imaging conditions (13-16 pixels/fiber). Determining fibrin clot porosity via DiameterJ is challenging.


Assuntos
Fibrina/ultraestrutura , Hemorragia/diagnóstico por imagem , Plasma/diagnóstico por imagem , Trombose/diagnóstico , Adulto , Coagulação Sanguínea/genética , Feminino , Fibrina/química , Hemorragia/diagnóstico , Hemorragia/patologia , Humanos , Microscopia Eletrônica de Varredura , Porosidade , Gravidez , Trombose/sangue , Trombose/diagnóstico por imagem , Trombose/patologia
2.
Acta Radiol ; 62(1): 51-57, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32290676

RESUMO

BACKGROUND: Many factors influence the increase in signal intensity (SI) provided by magnetic resonance imaging (MRI) contrast media. PURPOSE: To assess the impact of different gadolinium concentrations and dilutions of three macrocyclic gadolinium-based contrast agents (GBCA) on SI. MATERIAL AND METHODS: This phantom study investigated gadobutrol, gadoteridol, and gadoterate in human plasma of a healthy donor pool at 37 °C. Different molar concentrations served to mimic conditions typically relevant for steady-state imaging; different dilutions served to mimic influence on first-pass bolus imaging. For SI measurement at 1.5T and 3T, we used two Magnetom Scanners (Siemens), applying the T1-weighted sequences Flash 2D/3D and VIBE. Regions of interest were placed on the central slice of the test vials. RESULTS: In the concentration series, gadobutrol showed the highest SI of all three GBCAs up to 2 mM, followed by gadoteridol and gadoterate. No major differences were seen between 1.5T and 3T. In the dilution series, gadobutrol showed the highest SI of all three GBCAs up to 10 mL/L. The highest effect was recorded with Flash 3D and VIBE at 3T. CONCLUSION: SIs measured in phantoms using three macrocyclic GBCAs strongly depend on their relaxivity and on the local concentration. The latter can be influenced-when comparing dilutions-by their initial concentration in their formulation. Furthermore, the pulse sequences and the chosen parameters have essential influence. At steady-state concentrations (≤2 mM) and first-pass bolus dilutions (up to 10 ml/L), gadobutrol showed highest SIs, followed by gadoterate and gadoteridol.


Assuntos
Meios de Contraste , Gadolínio , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Plasma/diagnóstico por imagem , Humanos , Imagens de Fantasmas
3.
Neurol India ; 68(1): 26-34, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32129239

RESUMO

Over the last decade, research has intensified worldwide on the use of low-temperature plasmas in medicine and healthcare. Researchers have discovered many methods of applying plasmas to living tissues to deactivate pathogens; to end the flow of blood without damaging healthy tissue; to sanitize wounds and accelerate its healing; and to selectively kill malignant cancer cells. This review paper presents the latest development of advanced and plasma-based technologies used for applications in neurology in particular. Institute for Plasma Research (IPR), an aided institute of the Department of Atomic Energy (DAE), has also developed various technologies in some of these areas. One of these is an Atmospheric Pressure Plasma Jet (APPJ). This device is being studied to treat skin diseases, for coagulation of blood at faster rates and its interaction with oral, lung, and brain cancer cells. In certain cases, in-vitro studies have yielded encouraging results and limited in-vivo studies have been initiated. Plasma activated water has been produced in the laboratory for microbial disinfection, with potential applications in the health sector. Recently, plasmonic nanoparticle arrays which allow detection of very low concentrations of chemicals is studied in detail to allow early-stage detection of diseases. IPR has also been developing AI-based software called DeepCXR and AIBacilli for automated, high-speed screening and detection of footprints of tuberculosis (TB) in Chest X-ray images and for recognizing single/multiple TB bacilli in sputum smear test images, respectively. Deep Learning systems are increasingly being used around the world for analyzing electroencephalogram (EEG) signals for emotion recognition, mental workload, and seizure detection.


Assuntos
Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia , Tuberculose/diagnóstico por imagem , Tuberculose/cirurgia , Academias e Institutos , Aprendizado Profundo , Humanos , Plasma/diagnóstico por imagem , Análise Espectral Raman/métodos
4.
Biochim Biophys Acta Mol Cell Biol Lipids ; 1864(3): 260-270, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30557627

RESUMO

Intermediate-density lipoproteins (IDLs), the remnants of very-low-density lipoproteins via lipolysis, are rich in cholesteryl ester and are associated with cardiovascular disease. Despite pharmacological interest in IDLs, their three-dimensional (3D) structure is still undetermined due to their variation in size, composition, and dynamic structure. To explore the 3D structure of IDLs, we reconstructed 3D density maps from individual IDL particles using cryo-electron microscopy (cryo-EM) and individual-particle electron tomography (IPET, without averaging from different molecules). 3D reconstructions of IDLs revealed an unexpected polyhedral structure that deviates from the generally assumed spherical shape model (Frias et al., 2007; Olson, 1998; Shen et al., 1977). The polyhedral-shaped IDL contains a high-density shell formed by flat surfaces that are similar to those of very-low-density lipoproteins but have sharper dihedral angles between nearby surfaces. These flat surfaces would be less hydrophobic than the curved surface of mature spherical high-density lipoprotein (HDL), leading to a lower binding affinity of IDL to hydrophobic proteins (such as cholesteryl ester transfer protein) than HDL. This is the first visualization of the IDL 3D structure, which could provide fundamental clues for delineating the role of IDL in lipid metabolism and cardiovascular disease.


Assuntos
Lipoproteínas IDL/química , Lipoproteínas IDL/fisiologia , Imagem Individual de Molécula/métodos , Apolipoproteína A-I/metabolismo , Apolipoproteínas B/metabolismo , Proteínas de Transferência de Ésteres de Colesterol/metabolismo , Ésteres do Colesterol/metabolismo , Microscopia Crioeletrônica/métodos , Tomografia com Microscopia Eletrônica/métodos , Voluntários Saudáveis , Humanos , Imageamento Tridimensional/métodos , Lipólise/fisiologia , Lipoproteínas/metabolismo , Lipoproteínas HDL/metabolismo , Lipoproteínas IDL/metabolismo , Lipoproteínas LDL/metabolismo , Lipoproteínas VLDL/metabolismo , Plasma/diagnóstico por imagem
5.
Curr Neurovasc Res ; 12(1): 31-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25557378

RESUMO

Alzheimer's disease (AD) is a significant source of morbidity and mortality for millions of people worldwide, and multiple potential etiologies have been postulated to contribute to AD. Among these, spontaneous cerebral emboli and increased cerebral and circulating heme oxygenase (Hmox) activity in AD patients are of particular interest, as two of the products of Hmox activity, carbon monoxide (CO) and iron enhance plasmatic coagulation and modify the ultrastructure of thrombi. We hypothesized that patients afflicted with AD would have coagulation kinetics modulated by CO and iron. Using viscoelastic assessments of coagulation, it was determined with a small cohort (n=11) of AD patients that all had enhancement of coagulation by CO, iron, or both. In a complementary fashion, it was determined that a separate cohort (n=12) of AD patients had thrombi with ultrastructural features consistent with iron and CO exposure as assessed with scanning electron microscopy. Further, when stratified by normal or abnormally increased serum ferritin concentrations (which can be increased by Hmox), the AD patients with abnormal ferritin concentrations had significantly thinner fibrin fiber diameters, not unlike that noted when normal plasma is mixed with iron or CO. In sum, AD patients were noted to have plasmatic coagulation kinetic and thrombus ultrastructural changes consistent with exposure to CO and iron. Future investigation of CO and iron in the pathogenesis of Alzheimer's disease is warranted.


Assuntos
Doença de Alzheimer/sangue , Coagulação Sanguínea/efeitos dos fármacos , Monóxido de Carbono/farmacologia , Ferro/farmacologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Ferritinas/metabolismo , Fibrinogênio/metabolismo , Humanos , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Plasma/diagnóstico por imagem , Plasma/metabolismo , Cintilografia , Trombina/metabolismo
6.
Phys Med Biol ; 58(22): 7889-903, 2013 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-24165043

RESUMO

This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3ß-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.


Assuntos
Artérias/diagnóstico por imagem , Plasma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Animais , Limite de Detecção , Masculino , Camundongos , Radioatividade , Ratos , Fatores de Tempo
7.
Neuroimage ; 66: 611-22, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-23108277

RESUMO

Quantitative PET studies with arterial blood sampling usually require the correction of the measured total plasma activity for the presence of metabolites. In particular, if labelled metabolites are found in the plasma in significant amounts their presence has to be accounted for, because it is the concentration of the parent tracer which is required for data quantification. This is achieved by fitting a Parent Plasma fraction (PPf) model to discrete metabolite measurements. The commonly used method is based on an individual approach, i.e. for each subject the PPf model parameters are estimated from its own metabolite samples, which are, in general, sparse and noisy. This fact can compromise the quality of the reconstructed arterial input functions, and, consequently, affect the quantification of tissue kinetic parameters. In this study, we proposed a Non-Linear Mixed Effect Modelling (NLMEM) approach to describe metabolite kinetics. Since NLMEM has been developed to provide robust parameter estimates in the case of sparse and/or noisy data, it has the potential to be a reliable method for plasma metabolite correction. Three different PET datasets were considered: [11C]-(+)-PHNO (54 scans), [11C]-PIB (22 scans) and [11C]-DASB (30 scans). For each tracer both simulated and measured data were considered and NLMEM performance was compared with that provided by individual analysis. Results showed that NLMEM provided improved estimates of the plasma parent input function over the individual approach when the metabolite data were sparse or contained outliers.


Assuntos
Algoritmos , Modelos Teóricos , Plasma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/sangue , Humanos , Dinâmica não Linear
8.
Invest Radiol ; 45(9): 554-8, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20697225

RESUMO

UNLABELLED: PURPOSE/INTRODUCTION: The aim of this study was to determine the T1 relaxivities (r1) of 8 gadolinium (Gd)-based MR contrast agents in human blood plasma at 7 Tesla, compared with 3 Tesla. SUBJECTS AND METHODS: Eight commercially available Gd-based MR contrast agents were diluted in human blood plasma to concentrations of 0, 0.25, 0.5, 1, and 2 mmol/L. In vitro measurements were performed at 37 degrees C, on a 7 Tesla and on a 3 Tesla whole-body magnetic resonance imaging scanner. For the determination of T1 relaxation times, Inversion Recovery Sequences with inversion times from 0 to 3500 ms were used. The relaxivities were calculated. RESULTS: The r1 relaxivities of all agents, diluted in human blood plasma at body temperature, were lower at 7 Tesla than at 3 Tesla. The values at 3 Tesla were comparable to those published earlier. Notably, in some agents, a minor negative correlation of r1 with a concentration of up to 2 mmol/L could be observed. This was most pronounced in the agents with the highest protein-binding capacity. DISCUSSION/CONCLUSION: At 7 Tesla, the in vitro r1 relaxivities of Gd-based contrast agents in human blood plasma are lower than those at 3 Tesla. This work may serve as a basis for the application of Gd-based MR contrast agents at 7 Tesla. Further studies are required to optimize the contrast agent dose in vivo.


Assuntos
Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética/instrumentação , Plasma/diagnóstico por imagem , Meios de Contraste/química , Meios de Contraste/farmacocinética , Estudos de Viabilidade , Gadolínio/química , Gadolínio/farmacocinética , Humanos , Técnicas In Vitro , Imageamento por Ressonância Magnética/métodos , Plasma/química , Cintilografia , Estatística como Assunto
9.
J Nucl Med ; 51(1): 112-20, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20008988

RESUMO

UNLABELLED: We recently demonstrated that (11)C-MePPEP, a PET ligand for CB(1) receptors, has such high uptake in the human brain that it can be imaged for 210 min and that receptor density can be quantified as distribution volume (V(T)) using the gold standard of compartmental modeling. However, (11)C-MePPEP had relatively poor retest and intersubject variabilities, which were likely caused by errors in the measurements of radioligand in plasma at low concentrations by 120 min. We sought to find an analog of (11)C-MePPEP that would provide more accurate plasma measurements. We evaluated several promising analogs in the monkey brain and chose the (18)F-di-deutero fluoromethoxy analog ((18)F-FMPEP-d(2)) to evaluate further in the human brain. METHODS: (11)C-FMePPEP, (18)F-FEPEP, (18)F-FMPEP, and (18)F-FMPEP-d(2) were studied in 5 monkeys with 10 PET scans. We calculated V(T) using compartmental modeling with serial measurements of unchanged parent radioligand in arterial plasma and radioactivity in the brain. Nonspecific binding was determined by administering a receptor-saturating dose of rimonabant, an inverse agonist at the CB(1) receptor. Nine healthy human subjects participated in 17 PET scans using (18)F-FMPEP-d(2), with 8 subjects having 2 PET scans to assess retest variability. To identify sources of error, we compared intersubject and retest variability of brain uptake, arterial plasma measurements, and V(T). RESULTS: (18)F-FMPEP-d(2) had high uptake in the monkey brain, with greater than 80% specific binding, and yielded less radioactivity uptake in bone than did (18)F-FMPEP. High brain uptake with (18)F-FMPEP-d(2) was also observed in humans, in whom V(T) was well identified within approximately 60 min. Retest variability of plasma measurements was good (16%); consequently, V(T) had a good retest variability (14%), intersubject variability (26%), and intraclass correlation coefficient (0.89). V(T) increased after 120 min, suggesting an accumulation of radiometabolites in the brain. Radioactivity accumulated in the skull throughout the entire scan but was thought to be an insignificant source of data contamination. CONCLUSION: Studies in monkeys facilitated our development and selection of (18)F-FMPEP-d(2), compared with (18)F-FMPEP, as a radioligand demonstrating high brain uptake, high percentage of specific binding, and reduced uptake in bone. Retest analysis in human subjects showed that (18)F-FMPEP-d(2) has greater precision and accuracy than (11)C-MePPEP, allowing smaller sample sizes to detect a significant difference between groups.


Assuntos
Encéfalo/diagnóstico por imagem , Fluordesoxiglucose F18 , Pirrolidinonas , Compostos Radiofarmacêuticos , Receptor CB1 de Canabinoide/agonistas , Receptor CB1 de Canabinoide/metabolismo , Adulto , Animais , Área Sob a Curva , Química Encefálica , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Marcação por Isótopo , Macaca mulatta , Masculino , Plasma/diagnóstico por imagem , Cintilografia , Compostos Radiofarmacêuticos/síntese química , Crânio/diagnóstico por imagem , Adulto Jovem
10.
Cell Mol Biol (Noisy-le-grand) ; 55(3): 23-8, 2009 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-20003808

RESUMO

Radionuclides are used in nuclear medicine by variety of diagnostic procedures. The labeling of red blood cells (RBC) with (99m)Tc is a current method applied in clinical nuclear medicine. Drugs can alter this labeling and modify the disposition of the radiopharmaceuticals. The influence of Rochagan on the labeling of blood constituents with (99m)Tc was reported. Samples of blood were incubated with different concentrations of Rochagan (0%; 6.25%; 12.5%; 25%; 50%; 100%). Stannous chloride and (99m)Tc (3.7MBq/mL) were added. Plasma (P) and (RBC) were isolated and precipitated with thricloroacetic acid 5%. The insoluble (IF) and soluble fractions (SF) were separated. The %ATI in RBC, IF-P and IF-RBC were calculated. The %ATI on RBC decreased significantly (p<0.05) from control to all concentrations of Rochagan, respectively: 90.15 + or - 0.14(control) to 70.80 + or - 4.21; to 64.36 + or - 0.33; to 57.30 + or - 1.56; to 50.28 + or - 2.71; to 42.41 + or - 2.24; on IF-RBC, respectively: 84.70 + or - 0.87(control) to 67.16 + or - 4.38; to 63.63 + or - 2.92; to 59.02 + or - 3.17; to 43.75 + or - 1.00; to 24.15 + or - 0.94 and also on IF-P, respectively: 83.46 + or - 1.09(control) to 50.90 + or - 3.36; to 35.46 + or - 4.13; to 35.78 + or - 2.31; to 28.74 + or - 3.09; to 19.66 + or - 1.34. The analyses were performed by T-Student and Mann Whitney tests, p<0.05. This effect was probably due to products present in Rochagan that may complex with ions or have a direct/indirect effect on intracellular stannous ion concentration.


Assuntos
Eritrócitos/diagnóstico por imagem , Nitroimidazóis/metabolismo , Plasma/diagnóstico por imagem , Compostos Radiofarmacêuticos/metabolismo , Tecnécio/metabolismo , Tripanossomicidas/metabolismo , Animais , Humanos , Nitroimidazóis/química , Cintilografia , Compostos Radiofarmacêuticos/química , Ratos , Ratos Wistar , Tecnécio/química , Compostos de Estanho/química , Compostos de Estanho/metabolismo , Tripanossomicidas/química
11.
Bioorg Med Chem Lett ; 19(18): 5436-9, 2009 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-19679469

RESUMO

A series of trans-3-oxospiro[(aza)isobenzofuran-1(3H),1'-cyclohexane]-4'-carboxamide derivatives were synthesized and profiled for NPY Y5 binding affinity, brain and CSF penetrability in rats, and susceptibility to human and mouse P-glycoprotein transporters in order to develop a PET ligand. Compound 12b exhibited an acceptable profile for a PET ligand, and [(11)C]12b was successfully utilized in clinical settings as a Y5 PET ligand.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Ensaio Radioligante/métodos , Receptores de Neuropeptídeo Y/metabolismo , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/metabolismo , Animais , Encéfalo/metabolismo , Linhagem Celular , Líquido Cefalorraquidiano/diagnóstico por imagem , Humanos , Ligantes , Camundongos , Plasma/diagnóstico por imagem , Ligação Proteica , Ratos , Relação Estrutura-Atividade
12.
Nucl Med Biol ; 35(4): 515-21, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18482689

RESUMO

INTRODUCTION: To complement recent studies using the high-affinity (11)C-labeled phosphodiesterase-4 (PDE4) inhibitor (R)-rolipram and the less active enantiomer (S)-[(11)C]rolipram for in vivo quantification of PDE4 levels, we evaluated the presence of radiolabeled metabolites and their potential binding to PDE4 in the rat plasma, brain, heart, pancreas, skeletal muscle and brown adipose tissue. METHODS: A reverse-phase capture and analytical HPLC column-switch method was used to detect (R)-[(11)C]rolipram, (S)-[(11)C]rolipram and their radiolabeled metabolites in rat plasma and tissue extracts. The relative proportion of PDE4-specific binding of the radiotracers and their labeled metabolites was analyzed following co-injections with a saturating dose of unlabeled (R)-rolipram at 45 min post-tracer injection in tissue extracts. RESULTS: Radiolabeled metabolites were found in the plasma (72-75% of total radioactive signal), and in the heart, skeletal muscle, pancreas and brown adipose tissue (44-52%), but not in the brain. In comparison to polar labeled metabolites, the proportion of unchanged (R)-[(11)C]rolipram was reduced in PDE4-rich organs by co-injection of unlabeled (R)-rolipram. Conversely, no changes were obtained in brown adipose tissue, or with (S)-[(11)C]rolipram, suggesting that radiolabeled metabolites of (R)-[(11)C]rolipram display no specific binding to PDE4. CONCLUSIONS: Radiolabeled hydrophilic metabolites are unlikely to compete with (R)-[(11)C]rolipram for PDE4-specific retention. However, due to the high proportion of the radioactive metabolites in the total radioactive signal, any kinetic modeling calculations in the peripheral tissues will need to take into account the presence of labeled metabolites.


Assuntos
Nucleotídeo Cíclico Fosfodiesterase do Tipo 4/análise , Rolipram/análogos & derivados , Rolipram/farmacocinética , Tecido Adiposo Marrom/diagnóstico por imagem , Animais , Ligação Competitiva , Encéfalo/diagnóstico por imagem , Radioisótopos de Carbono/farmacocinética , Cromatografia Líquida de Alta Pressão , Coração/diagnóstico por imagem , Interações Hidrofóbicas e Hidrofílicas , Masculino , Músculo Esquelético/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Inibidores da Fosfodiesterase 4 , Inibidores de Fosfodiesterase/farmacocinética , Plasma/diagnóstico por imagem , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Ratos Sprague-Dawley , Estereoisomerismo , Distribuição Tecidual , Contagem Corporal Total
13.
Acta Physiol Hung ; 95(1): 87-95, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18390001

RESUMO

Blood constituents labeled with technetium-99m (99mTc) have been used in nuclear medicine procedures and drugs are capable to interfere on this labeling. Lantana camara (lantana) has medicinal properties and it has been used in folk medicine. The aim is to verify the effect of a lantana extract on the labeling of blood constituents with 99mTc. Blood of rats was incubated with extract, stannous chloride and 99mTc, as sodium pertechnetate. Plasma (P) and blood cells (BC) were isolated, also precipitated with trichloroacetic acid and soluble (SF) and insoluble fractions (IF) were separated. The % of radioactivity (%ATI) in these samples was calculated. Samples of labeled BC were washed and the %ATI maintained (%ATI-M) in the BC was determined. The results showed that lantana extract decreased significantly (p < 0.05) in the IF-P from 70.24 +/- 2.59 to 11.95 +/- 3.07. This effect was not observed in the BC and IF-BC. The BC-%ATI-M was significantly (p < 0.05) decreased in all concentrations tested when the BC was washed. This fact was not observed in the control. Substances present on the extract should have redoxi action decreasing the concentration of the stannous ion and this condition could justify the effect on the IF-P. The results about the BC-%ATI-M should indicate a possible effect on the transport of ions through the erythrocyte membrane.


Assuntos
Células Sanguíneas/efeitos dos fármacos , Células Sanguíneas/diagnóstico por imagem , Lantana/efeitos adversos , Plasma/efeitos dos fármacos , Plasma/diagnóstico por imagem , Tecnécio/farmacocinética , Animais , Marcação por Isótopo/normas , Masculino , Extratos Vegetais/efeitos adversos , Folhas de Planta/efeitos adversos , Cintilografia , Ratos , Ratos Wistar , Pertecnetato Tc 99m de Sódio/farmacocinética , Compostos de Estanho , Distribuição Tecidual/efeitos dos fármacos
14.
Nucl Med Biol ; 34(6): 681-9, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17707808

RESUMO

[(11)C]MeS-IMPY ([S-methyl-(11)C]N,N-dimethyl-4-(6-(methylthio)imidazo[1,2-a]pyridine-2-yl)aniline) is a potential radioligand for imaging beta-amyloid plaques with positron emission tomography (PET). The aims of this study were to evaluate [(11)C]MeS-IMPY uptake in nonhuman primate brain and to estimate radiation exposure from serial whole-body images. Eight PET studies were performed in rhesus monkeys to measure the brain uptake and washout of [(11)C]MeS-IMPY. Time-activity data were analyzed with one-tissue and two-tissue compartmental models using radiometabolite-corrected plasma input function. In addition, two whole-body PET scans were acquired for 120 min to determine the biodistribution of [(11)C]MeS-IMPY. Tomographic PET images were compressed into a single planar image to identify organs with the highest radiation exposures. Estimates of the absorbed dose of radiation were calculated using OLINDA 1.0. Injection of [(11)C]MeS-IMPY caused little change in pulse rate, blood pressure, respiratory rate and temperature. [(11)C]MeS-IMPY showed high standardized brain uptake values of approximately 500% and 600% between 2 and 3 min in cortical regions and the cerebellum, respectively. The brain uptake of [(11)C]MeS-IMPY was widespread and quite uniform across all cortical regions. Activity rapidly washed out of the brain, with 20% of peak activity remaining at 40 min. Thus, all brain regions showed minimal retention of radioactivity, consistent with these healthy young animals having negligible amyloid plaques. Regional brain activity fitted well into a one-tissue compartment model. The average volume of distribution in all brain regions was 7.66+/-2.14 ml/cm(3) (n=4). The organs with the highest radiation exposure (muSv/MBq) were the gallbladder wall (33.4), urinary bladder (17) and lungs (12.9), with a resulting effective dose of 4.9 microSv/MBq (18 mrem/mCi). The high brain uptake, rapid washout and quantifiable volume of distribution in nonhuman primate brain further support the evaluation of [(11)C]MeS-IMPY. Calculated dosimetry results are comparable with those for other (11)C-labeled brain imaging radioligands.


Assuntos
Compostos de Anilina , Encéfalo/diagnóstico por imagem , Compostos Bicíclicos Heterocíclicos com Pontes , Placa Amiloide/diagnóstico por imagem , Compostos Radiofarmacêuticos , Imagem Corporal Total/métodos , Peptídeos beta-Amiloides/metabolismo , Animais , Artérias/diagnóstico por imagem , Radioisótopos de Carbono , Marcação por Isótopo , Macaca mulatta , Masculino , Placa Amiloide/metabolismo , Plasma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Radiometria
15.
Ultrasound Med Biol ; 32(7): 1055-64, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16829319

RESUMO

The blood coagulation mechanism consists of a series of concatenated chemical reactions, governed by the coagulation factors present in the blood plasma, after the activation of the clot mechanism. The last reaction corresponds to the fibrinogen conversion into fibrin, followed by the fibrin polymerisation and production of a stable fibrin network. During the clotting process, there is a sol-gel transformation of the medium. The subject of the present paper is the measurement of the ultrasonic attenuation coefficient for human blood plasma during the coagulation process, in the frequency range of 8 to 22 MHz. The clot was obtained after the procedure to measure the prothrombin time (approximately 12 s): mixing 150 microL of reconstituted lyophilised normal plasma with 300 microL of reconstituted lyophilised thromboplastin immersed in a water bath with the temperature controlled at 36.5 degrees C. The attenuation coefficient for pure plasma remained constant within the measurement period of 10 s and at frequencies of 8, 9, 10, 15, 20, 21 and 22 MHz. On the other hand, there is a detectable time-decay of the attenuation coefficient for samples of plasma going through the coagulation process and at frequencies of 8, 9, 10 and 15 MHz. The time-decay becomes less and less detectable as the frequency increases and it becomes completely undetectable at 20, 21 and 22 MHz.


Assuntos
Coagulação Sanguínea , Interpretação de Imagem Assistida por Computador , Plasma/diagnóstico por imagem , Ultrassonografia Doppler de Pulso , Fibrina , Humanos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Ultrassonografia Doppler de Pulso/instrumentação
16.
Nucl Med Rev Cent East Eur ; 7(1): 31-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15318308

RESUMO

BACKGROUND: The aim of this study was to present and compare the results of proposed methods for optimal red cell mass and plasma volume (RCM&PV) estimation, and their influence on the interpretation of obtained results. MATERIAL AND METHODS: In 120/280 patients with polycythaemia rubra vera, subjected to RCM&PV determination with autologous erythrocytes in vitro labelled with 51Cr-sodium chromate, optimal volumes were determined using: 1. traditional ml/kg of: --the real body weight method (ml/kg RBW); --the optimal body weight method (ml/kg OBW). 2. the body weight, height, and sex based method (Retzlaff's tables), 3. the method recommended by the International Council for Standardization in Haematology (ICSH), based on body surface area. RESULTS: Different interpretation of the same results of 120 RCM&PV measurements was registered in 48/120 patients (40%). The greatest disagreement existed between ml/kg RBW and ml/kg OBW methods (in 39/120 subjects, 32.5%). In underweight patients the ml/kg RBW method, and in overweight patients the ml/kg OBW method, offered better agreement with ICSH&Retzlaff's methods. The ml/kg RBW method disagreed with ICSH&Retzlaff's methods and ml/kg OBW in 25% and 19.2% of patients respectively. ICSH and Retzlaff's methods disagreed in 10/120 patients (8.3%). The ICSH method yielded significantly lower optimal volumes than Retzlaff's. CONCLUSION: Three methods for optimal RCM&PV estimation lead to different interpretations of the same results of RCM&PV measurements with 51Cr-erythrocytes in 40% of patients. Two ml/kg body weight methods show greater disagreement in comparison with ICSH and Retzlaff's methods, which differ significantly. The ICSH method yields lower optimal values compared to Retzlaff's.


Assuntos
Determinação do Volume Sanguíneo/métodos , Eritrócitos/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Volume Plasmático , Plasma/diagnóstico por imagem , Policitemia Vera/sangue , Policitemia Vera/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Determinação do Volume Sanguíneo/normas , Composição Corporal , Cromatos/sangue , Guias como Assunto , Humanos , Interpretação de Imagem Assistida por Computador/normas , Marcação por Isótopo/métodos , Pessoa de Meia-Idade , Policitemia Vera/fisiopatologia , Cintilografia , Compostos Radiofarmacêuticos/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Compostos de Sódio/sangue
17.
Nucl Med Biol ; 30(1): 61-72, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12493544

RESUMO

Two DNA aptamers directed against two separate exosites on human alpha-thrombin were evaluated for thrombus-imaging potential. Aptamer ODN 1 is directed to the thrombin substrate binding site (exosite 1). Our finding that ODN 1 competes with fibrin for binding to exosite 1 on thrombin suggests that ODN 1 will not be useful for thrombus imaging. Aptamer ODN 2 is directed against the thrombin heparin binding site (exosite 2). ODN 2 bound to model thrombi that were formed either by clotting purified fibrinogen with thrombin, or by recalcifying citrated plasma. As the thrombin content of thrombi was increased the rate of ODN 2 uptake into preformed thrombi increased, whereas the rate of release of ODN 2 out of preformed thrombi decreased. This in vitro data suggested that ODN 2 might be useful for thrombus imaging because it can bind to exosite 2 on fibrin-bound thrombin. However, in a rabbit jugular vein model using thrombus supplemented with human thrombin, ODN 2 uptake was equal to the ovalbumin control, and did not reflect thrombin content. While the in vitro results with ODN 2 were consistent with thrombus imaging, the rapid clearance of ODN 2 from circulation, combined with slow mass transfer in the clot, seem to work against in vivo thrombin-dependent imaging or washout analysis.


Assuntos
Radioisótopos do Iodo/farmacocinética , Oligonucleotídeos/farmacocinética , Trombina/metabolismo , Trombose/diagnóstico por imagem , Trombose/metabolismo , Animais , Anticoagulantes/sangue , Anticoagulantes/farmacocinética , Sequência de Bases , Sítios de Ligação/genética , DNA/sangue , DNA/farmacocinética , Endotélio Vascular/diagnóstico por imagem , Endotélio Vascular/lesões , Endotélio Vascular/metabolismo , Feminino , Fibrinogênio/metabolismo , Fluoroscopia/métodos , Humanos , Radioisótopos do Iodo/sangue , Marcação por Isótopo/métodos , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/metabolismo , Ligantes , Dados de Sequência Molecular , Oligonucleotídeos/sangue , Oligonucleotídeos/classificação , Plasma/diagnóstico por imagem , Plasma/metabolismo , Ligação Proteica , Coelhos , Cintilografia , Compostos Radiofarmacêuticos/sangue , Compostos Radiofarmacêuticos/farmacocinética , Serina Endopeptidases/farmacologia
18.
Ultrasound Med Biol ; 28(3): 377-82, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11978418

RESUMO

Ultrasound (US) accelerates enzymatic fibrinolysis in vitro and in animal models, and may be a useful adjunctive therapy for clinical thrombolysis. Successful clinical application will depend on the selection of appropriate US parameters to optimize fibrinolytic enhancement while limiting adverse effects, including heating. Most studies have been done at megahertz frequencies, but tissue penetration is better and heating less at lower frequencies. We have, therefore, now investigated the effects of continuous-wave and pulsed US on fibrinolysis at midkilohertz frequencies. Fibrinolysis with tissue plasminogen activator (t-PA) was measured by solubilization of radiolabeled fibrin exposed to a calibrated US field in a temperature-controlled water bath. There was significant enhancement of fibrinolysis at frequencies of 27, 40 and 100 kHz, with the greatest effect observed at 27 kHz. The largest effect was observed with continuous-wave US, but significant acceleration was also observed with peak intensities of 1 W/cm(2) duty cycles of 10% and 1%. At a 10% duty cycle, there was approximately 60% of the fibrinolytic enhancement observed with continuous-wave exposure, indicating a clear advantage of pulsing to optimize fibrinolytic effect and limit exposure. We conclude that US in the range of 27 to 100 kHz is effective in accelerating fibrinolysis at intensities and pulsing conditions that minimize the probability of heating and cavitation in clinical applications.


Assuntos
Coagulação Sanguínea/fisiologia , Fibrinólise/fisiologia , Plasma/diagnóstico por imagem , Ultrassom , Análise de Variância , Humanos , Ativador de Plasminogênio Tecidual/fisiologia , Ultrassonografia Doppler de Pulso
19.
Ann Nucl Med ; 16(7): 507-10, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12508846

RESUMO

The effect of rolipram, a selective phosphodiesterase type 4 inhibitor, on the uptake of 18F-fluorodeoxyglucose (18F-FDG) in tumor tissue was examined in mice transplanted with NFSa fibrosarcoma. The uptake indexes of 18F-FDG in the heart, skeletal muscle and brain remarkably decreased after treatment with 3 mg/kg of rolipram (heart: 13%, skeletal muscle: 14%, brain: 31%), but fibrosarcoma tissue showed only a 50% reduction in the uptake index of 18F-FDG. The tumor/muscle ratio of radioactivity 30 min after 18F-FDG injection was consequently enhanced from 1.9 to 6.5 by rolipram. This indicates the possible use of rolipram to enhance the sensitivity of tumor detection, as well as characterization of tumors in 18F-FDG PET.


Assuntos
Fibrossarcoma/diagnóstico por imagem , Fibrossarcoma/metabolismo , Fluordesoxiglucose F18/farmacocinética , Rolipram/farmacologia , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Coração/diagnóstico por imagem , Coração/efeitos dos fármacos , Membro Posterior/cirurgia , Aumento da Imagem/métodos , Masculino , Camundongos , Camundongos Endogâmicos C3H , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/metabolismo , Músculo Esquelético/cirurgia , Miocárdio/metabolismo , Transplante de Neoplasias , Plasma/diagnóstico por imagem , Plasma/metabolismo , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética , Sensibilidade e Especificidade , Distribuição Tecidual
20.
Ultrasound Med Biol ; 26(5): 881-8, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10942835

RESUMO

A technique to efficiently separate plasma from human whole blood is described. Essentially, 3-mL samples are held on the axis of a tubular transducer and exposed for 5.7 min to an ultrasonic standing wave. The cells concentrate into clumps at radial separations of half wavelength. The clumps grow in size and sediment under gravity. A distinct plasma/cell interface forms as the cells sediment. The volume of clarified plasma increases with time. The separation efficiencies of transducers of 29-mm and 23-mm internal diameters driven, by test equipment, at radial resonances of 3.4 and 1.5 MHz, respectively, were compared. The average efficiency of separation was 99.6% at 1.5 MHz and 99.4% with the 3.4-MHz system. The cleared plasma constituted 30% of the sample volume at 1.5 MHz and 25% at 3. 4 MHz. There was no measurable release of haemoglobin or potassium into the suspending phase, indicating that there was no mechanical damage to cells at either frequency. A total of 114 samples from volunteers and patients were subsequently clarified in a 1.5-MHz system driven by an integrated generator. The average efficiency of clarification of blood was 99.76% for the latter samples. The clarification achieved is a significant improvement on that previously reported (98.5%) for whole blood exposed to a planar ultrasonic standing wave field (Peterson et al. 1986). We have, therefore, now achieved a six-fold reduction of cells in plasma compared to previous results.


Assuntos
Sangue/diagnóstico por imagem , Sonicação , Sangue/metabolismo , Contagem de Células Sanguíneas , Análise Química do Sangue , Hemoglobinas/metabolismo , Humanos , Plasma/diagnóstico por imagem , Plasma/metabolismo , Potássio/sangue , Reprodutibilidade dos Testes , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...