Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.516
Filtrar
1.
Anal Chem ; 96(28): 11172-11180, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-38946102

RESUMO

Improving separation efficiency in capillary electrophoresis (CE) requires systematic study of the influence of the electric field (or solute linear velocity) on plate height for a better understanding of the critical parameters controlling peak broadening. Even for poly(diallyldimethylammonium chloride) (PDADMAC)/poly(sodium styrenesulfonate) (PSS) successive multiple ionic-polymer layer (SMIL) coatings, which lead to efficient and reproducible separations of proteins, plate height increases with migration velocity, limiting the use of high electric fields in CE. Solute adsorption onto the capillary wall was generally considered as the main source of peak dispersion, explaining this plate height increase. However, experiments done with Taylor dispersion analysis and CE in the same conditions indicate that other phenomena may come into play. Protein adsorption with slow kinetics and few adsorption sites was established as a source of peak broadening for specific proteins. Surface charge inhomogeneity was also identified as a contribution to plate height due to local electroosmotic fluctuations. A model was proposed and applied to partial PDADMAC/poly(ethylene oxide) capillary coatings as well as PDADMAC/PSS SMIL coatings. Atomic force microscopy with topography and recognition imaging enabled the determination of roughness and charge distribution of the PDADMAC/PSS SMIL surface.


Assuntos
Eletro-Osmose , Eletroforese Capilar , Polietilenos , Eletroforese Capilar/métodos , Adsorção , Polietilenos/química , Proteínas/isolamento & purificação , Proteínas/química , Proteínas/análise , Compostos de Amônio Quaternário/química , Animais , Propriedades de Superfície
2.
J Oleo Sci ; 73(7): 953-961, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38945924

RESUMO

Handwashing represents an important personal hygiene measure for preventing infection. Herein, we report the persistence of antibacterial and antiviral effects after handwashing with fatty acid salt-based hand soap. To this end, we developed a new in vitro test method to measure persistence, utilizing coacervation formed by anionic surfactants and cationic polymers to retain highly effective soap components against each bacterium and virus on the skin. Coacervation with fatty acid salts and poly diallyldimethylammonium chloride (PDADMAC) as a cationic polymer allowed the persistence of antibacterial and antiviral effects against E. coli, S. aureus, and influenza virus even 4 h after handwashing. Furthermore, we confirmed an increase in the number of residual components effective against each bacterium and virus on the skin. In summary, the current findings describe an effective approach for enhancing the protective effects of handwashing.


Assuntos
Antibacterianos , Antivirais , Escherichia coli , Desinfecção das Mãos , Polietilenos , Compostos de Amônio Quaternário , Pele , Sabões , Staphylococcus aureus , Tensoativos , Sabões/farmacologia , Escherichia coli/efeitos dos fármacos , Desinfecção das Mãos/métodos , Compostos de Amônio Quaternário/farmacologia , Antibacterianos/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Antivirais/farmacologia , Pele/efeitos dos fármacos , Pele/microbiologia , Tensoativos/farmacologia , Humanos , Ácidos Graxos/farmacologia , Ácidos Graxos/análise , Fatores de Tempo , Orthomyxoviridae/efeitos dos fármacos
3.
Biomed Phys Eng Express ; 10(5)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38906123

RESUMO

In this study tissue equivalency of the polymeric materials was investigated by comparing with ICRP 110 Male Adult Computational Phantom tissues. For this purpose, radiological properties of polyamide (PA), high density polyethylene (HDPE), ultra-high molecular weight polyethylene (UHMWPE), polypropylene (PP), polyvinyl chloride (PVC), polytetrafluoroethylene (PTFE), polyethylene terephthalate (PET), polyoxymethylene (POM) and polyurethane foam (PU FOAM) were evaluated in the diagnostic energy range (15-150 keV). The radiological properties of the materials and ICRP 110 Male and Female Adult Computational Phantom tissues were calculated with Phy-X/PSD software. No major differences were seen except for sex-specific organs, and comparisons were made using an adult male phantom. To confirm the results experimentally, a chest phantom was designed with the polymeric materials. The phantom was scanned by Siemens SOMATOM Edge CT device with tube voltage of 120 kVp and Hounsfield Unit (HU) values were measured. In addition, HU values were calculated using theoretical relationships and significant agreement was obtained between measured and calculated HUs. It was determined that PA, PP, UHMWPE and HDPE were equivalent to muscle and adipose tissue, PVC and PTFE were equivalent to mineral bone, PET and POM were equivalent to spongiosa bone and PU FOAM was equivalent to lung tissue.


Assuntos
Imagens de Fantasmas , Polímeros , Humanos , Masculino , Polímeros/química , Feminino , Adulto , Tomografia Computadorizada por Raios X/métodos , Teste de Materiais , Polietilenos/química
4.
BMC Oral Health ; 24(1): 696, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38879492

RESUMO

BACKGROUND: An optimum restoration for reconstructing endodontically treated teeth should provide excellent marginal adaptation, high fracture resistance as well as maximum tooth structure conservation. The purpose of this study was to evaluate the marginal adaptation and fatigue resistance of different coronal restorations in endodontically treated premolars. METHODS: Thirty sound maxillary first premolars were endodontically treated and received MOD cavities. Teeth were randomly allocated into three groups (n = 10) according to the type of coronal restoration: Group R: polyethylene fibers (ribbond), fibers-reinforced composite (everX posterior) and final layer of nano-hybrid composite. Group O: indirect lithium disilicate overlay and Group C: fiber-post, resin composite restoration, and lithium disilicate crown. Marginal gap assessment was performed before and after thermocycling (5000 cycles) using stereomicroscope. Samples were subjected to stepwise-stress loading starting at 200 N, and increased by 100 N in each step until failure occurred. Statistical analysis was done by One-way ANOVA followed Tukey`s Post Hoc test for multiple comparison. Paired t test was used to compare the marginal adaptation before and after thermocycling. Survival probability was evaluated by Life table survival analysis. Failure mode analysis was performed with Chi-square test. RESULTS: Marginal gap was significantly the lowest in group R (37.49 ± 5.05) and (42.68 ± 2.38), while being the highest in group C (59.78 ± 5.67) and (71.52 ± 5.18) in before and after thermocycling respectively (P < 0.0001). Fatigue resistance was the highest for group O (1310.8 ± 196.7), and the lowest for group R (905.4 ± 170.51) with a significant difference between groups (P < 0.0001). Crown group had the highest percentage (80%) of catastrophic failure, while, overlay group exhibited the lowest (20%). CONCLUSIONS: Direct restoration without cuspal coverage using ribbon fibers with short FRC provided better marginal adaptation than indirect overlays and crowns, but fatigue resistance wasn't significantly improved. Adhesive ceramic overlays showed the best fatigue performance and the least catastrophic failure rate compared to both direct fiber-reinforced composite and indirect ceramic full coverage restorations. CLINICAL SIGNIFICANCE: Indirect adhesive overlays are a suitable, more conservative restorative option for endodontically treated teeth than full coverage restorations, especially when tooth structure is severely compromised.


Assuntos
Dente Pré-Molar , Resinas Compostas , Coroas , Adaptação Marginal Dentária , Técnica para Retentor Intrarradicular , Dente não Vital , Humanos , Resinas Compostas/química , Técnicas In Vitro , Restauração Dentária Permanente/métodos , Porcelana Dentária/química , Análise do Estresse Dentário , Polietilenos/química , Falha de Restauração Dentária , Teste de Materiais , Materiais Dentários/química
5.
ACS Appl Mater Interfaces ; 16(23): 29805-29822, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38830200

RESUMO

Periprosthetic osteolysis induced by the ultrahigh-molecular-weight polyethylene (UHMWPE) wear particles is a major complication associated with the sustained service of artificial joint prostheses and often necessitates revision surgery. Therefore, a smart implant with direct prevention and repair abilities is urgently developed to avoid painful revision surgery. Herein, we fabricate a phosphatidylserine- and polyethylenimine-engineered niobium carbide (Nb2C) MXenzyme-coated micro/nanostructured titanium implant (PPN@MNTi) that inhibits UHMWPE particle-induced periprosthetic osteolysis. The specific mechanism by which PPN@MNTi operates involves the bioresponsive release of nanosheets from the MNTi substrate within an osteolysis microenvironment, initiated by the cleavage of a thioketal-dopamine molecule sensitive to reactive oxygen species (ROS). Subsequently, functionalized Nb2C MXenzyme could target macrophages and escape from lysosomes, effectively scavenging intracellular ROS through its antioxidant nanozyme-mimicking activities. This further achieves the suppression of osteoclastogenesis by inhibiting NF-κB/MAPK and autophagy signaling pathways. Simultaneously, based on the synergistic effect of MXenzyme-integrated coatings and micro/nanostructured topography, the designed implant promotes the osteogenic differentiation of bone mesenchymal stem cells to regulate bone homeostasis, further achieving advanced osseointegration and alleviable periprosthetic osteolysis in vivo. This study provides a precise prevention and repair strategy of periprosthetic osteolysis, offering a paradigm for the development of smart orthopedic implants.


Assuntos
Nióbio , Osteogênese , Osteólise , Osteogênese/efeitos dos fármacos , Osteólise/patologia , Osteólise/prevenção & controle , Osteólise/metabolismo , Nióbio/química , Camundongos , Animais , Polietilenos/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Titânio/química , Células RAW 264.7 , Espécies Reativas de Oxigênio/metabolismo , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Osteoclastos/efeitos dos fármacos , Osteoclastos/metabolismo
6.
Talanta ; 277: 126433, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38901195

RESUMO

Analysis of real objects based on surface-enhanced Raman spectroscopy (SERS) often utilizes new SERS substrates and/or complex analysis procedures, and they are optimized for only the determination of a single analyte. Moreover, analysis simplicity and selectivity are often sacrificed for maximum (sometimes unnecessary) sensitivity. Consequently, this trend limits the versatility of SERS analysis and complicates its practical implementation. Thus, we have developed a universal, but simple SERS assay suitable for the determination of structurally related antibiotics (five representatives of the sulfanilamide class) in complex objects (human urine and saliva). The assay involves only mixing of acidified analyzed solution with co-activating agent (polydiallyldimethylammonium chloride - PDDA) and SERS substrate (standard colloidal silver nanoparticles). Acidification promotes the generation of SERS spectra with maximum similarity and intensity, which is explained by the favorable enhancement of the protonated sulfanilamide moiety (a structurally similar part of the studied antibiotics) as a result of its strong electrostatic interaction with the SERS-active surface. Meanwhile, the addition of PDDA improves analysis selectivity by reducing background signal from body fluids, enabling to simplify sample pretreatment (dilution for urine; mucin removal and dilution for saliva). Therefore, the assay allows for rapid (≤10 min), precise, and accurate class-specific determination of sulfanilamides within concentration ranges suitable for non-invasive therapeutic drug monitoring in urine (40-600 µM) and saliva (10-30 µM). We also believe that thorough investigation of structurally related analytes and accompanying effects (e.g., high spectral similarity) is a promising direction to improve the understanding of SERS in general and expand its capabilities as an analytical tool.


Assuntos
Antibacterianos , Compostos de Amônio Quaternário , Saliva , Análise Espectral Raman , Sulfanilamidas , Análise Espectral Raman/métodos , Humanos , Antibacterianos/análise , Antibacterianos/urina , Sulfanilamidas/química , Sulfanilamidas/análise , Compostos de Amônio Quaternário/química , Saliva/química , Prata/química , Polietilenos/química , Sulfanilamida/química , Nanopartículas Metálicas/química
7.
Talanta ; 276: 126290, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38805755

RESUMO

A very sensitive electrochemical biosensor, with haemoglobin (Hb) as its basis, has been created to quantify hydrogen peroxide (H2O2), an essential marker in environmental monitoring, food safety, and medical diagnosis. The sensor uses a simple, eco-friendly preparation method. Hb was immobilised on manganese dioxide nanostructure/gold nanoparticles/poly-diallydimethylammonium chloride-functionalised multiwalled carbon nanotubes (PDDA-MWCNT/AuNP/MnO2), characterised using various techniques: amperometry, voltammetry, X-ray diffraction (XRD), and transmission electron microscopy (TEM). Nafion was used as a binder membrane to preserve the biological and electrochemical properties of the protein on the modified electrode. In comparison to earlier research, the novel biosensor had a lower detection limit (1.83 µM) and a limit of quantification (6.11 µM) (S/N = 3) for H2O2. It also exhibited notable reproducibility, long-term stability, and repeatability. It was effectively used to measure the amount of H2O2 in cow milk and orange juice, yielding recoveries in the order of 98.90-99.53 % with RSDs less than 5.0 %, which makes it a promising biosensor for food control.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Ouro , Hemoglobinas , Peróxido de Hidrogênio , Compostos de Manganês , Nanopartículas Metálicas , Leite , Nanotubos de Carbono , Óxidos , Compostos de Amônio Quaternário , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Ouro/química , Hemoglobinas/análise , Hemoglobinas/química , Técnicas Biossensoriais/métodos , Compostos de Manganês/química , Nanopartículas Metálicas/química , Compostos de Amônio Quaternário/química , Nanotubos de Carbono/química , Óxidos/química , Técnicas Eletroquímicas/métodos , Leite/química , Animais , Polietilenos/química , Bovinos , Sucos de Frutas e Vegetais/análise , Limite de Detecção , Eletrodos
8.
APMIS ; 132(8): 553-563, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38741279

RESUMO

The use of highly crosslinked ultra-high molecular weight polyethylene (XLPE) has significantly reduced the volumetric wear of acetabular liners, thereby reducing the incidence of osteolysis. However, contemporary components tend to generate smaller wear particles, which can no longer be identified using conventional histology. This technical limitation can result in imprecise diagnosis. Here, we report on two uncemented total hip arthroplasty cases (~7 years in situ) revised for periprosthetic fracture of the femur and femoral loosening, respectively. Both liners exhibited prominent wear. The retrieved pseudocapsular tissue exhibited a strong macrophage infiltration without microscopically identifiable polyethylene particles. Yet, using Fourier-transform infrared micro-spectroscopic imaging (FTIR-I), we demonstrated the prominent intracellular accumulation of polyethylene debris in both cases. This study shows that particle induced osteolysis can still occur with XLPE liners, even under 10 years in situ. Furthermore, we demonstrate the difficulty of determining the presence of polyethylene debris within periprosthetic tissue. Considering the potentially increased bioactivity of finer particles from XLPE compared to conventional liners, an accurate detection method is required, and new histopathological hallmarks of particle induced osteolysis are needed. FTIR-I is a great tool to that end and can help the accurate determination of foreign body tissue responses.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Falha de Prótese , Humanos , Artroplastia de Quadril/efeitos adversos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Prótese de Quadril/efeitos adversos , Feminino , Polietilenos/química , Osteólise/etiologia , Osteólise/patologia , Osteólise/diagnóstico , Idoso , Masculino , Reoperação , Polietileno/química , Polietileno/efeitos adversos , Pessoa de Meia-Idade
9.
Anal Chem ; 96(18): 7014-7021, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38659215

RESUMO

Membrane-based lateral flow immunoassays (LFAs) have been employed as early point-of-care (POC) testing tools in clinical settings. However, the varying membrane properties, uncontrollable sample transport in LFAs, visual readout, and required large sample volumes have been major limiting factors in realizing needed sensitivity and desirable precise quantification. Addressing these challenges, we designed a membrane-free system in which the desirable three-dimensional (3D) structure of the detection zone is imitated and used a small pump for fluid flow and fluorescence as readout, all the while maintaining a one-step assay protocol. A hydrogel-like protein-polyelectrolyte complex (PPC) within a polyelectrolyte multilayer (PEM) was developed as the test line by complexing polystreptavidin (pSA) with poly(diallyldimethylammonium chloride) (PDDA), which in turn was layered with poly(acrylic acid) (PAA) resulting in a superior 3D streptavidin-rich test line. Since the remainder of the microchannel remains material-free, good flow control is achieved, and with the total volume of 20 µL, 7.5-fold smaller sample volumes can be used in comparison to conventional LFAs. High sensitivity with desirable reproducibility and a 20 min total assay time were achieved for the detection of NT-proBNP in plasma with a dynamic range of 60-9000 pg·mL-1 and a limit of detection of 56 pg·mL-1 using probe antibody-modified fluorescence nanoparticles. While instrument-free visual detection is no longer possible, the developed lateral flow channel platform has the potential to dramatically expand the LFA applicability, as it overcomes the limitations of membrane-based immunoassays, ultimately improving the accuracy and reducing the sample volume so that finger-prick analyses can easily be done in a one-step assay for analytes present at very low concentrations.


Assuntos
Biomarcadores , Compostos de Amônio Quaternário , Humanos , Imunoensaio/métodos , Biomarcadores/análise , Biomarcadores/sangue , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/análise , Limite de Detecção , Resinas Acrílicas/química , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/sangue , Polietilenos/química , Poliestirenos/química
10.
Int J Nanomedicine ; 19: 3697-3714, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38681091

RESUMO

Introduction: Over 75% of clinical microbiological infections are caused by bacterial biofilms that grow on wounds or implantable medical devices. This work describes the development of a new poly(diallyldimethylammonium chloride) (PDADMAC)/alginate-coated gold nanorod (GNR/Alg/PDADMAC) that effectively disintegrates the biofilms of Staphylococcus aureus (S. aureus), a prominent pathogen responsible for hospital-acquired infections. Methods: GNR was synthesised via seed-mediated growth method, and the resulting nanoparticles were coated first with Alg and then PDADMAC. FTIR, zeta potential, transmission electron microscopy, and UV-Vis spectrophotometry analysis were performed to characterise the nanoparticles. The efficacy and speed of the non-coated GNR and GNR/Alg/PDADMAC in disintegrating S. aureus-preformed biofilms, as well as their in vitro biocompatibility (L929 murine fibroblast) were then studied. Results: The synthesised GNR/Alg/PDADMAC (mean length: 55.71 ± 1.15 nm, mean width: 23.70 ± 1.13 nm, aspect ratio: 2.35) was biocompatible and potent in eradicating preformed biofilms of methicillin-resistant (MRSA) and methicillin-susceptible S. aureus (MSSA) when compared to triclosan, an antiseptic used for disinfecting S. aureus colonisation on abiotic surfaces in the hospital. The minimum biofilm eradication concentrations of GNR/Alg/PDADMAC (MBEC50 for MRSA biofilm = 0.029 nM; MBEC50 for MSSA biofilm = 0.032 nM) were significantly lower than those of triclosan (MBEC50 for MRSA biofilm = 10,784 nM; MBEC50 for MRSA biofilm 5967 nM). Moreover, GNR/Alg/PDADMAC was effective in eradicating 50% of MRSA and MSSA biofilms within 17 min when used at a low concentration (0.15 nM), similar to triclosan at a much higher concentration (50 µM). Disintegration of MRSA and MSSA biofilms was confirmed by field emission scanning electron microscopy and confocal laser scanning microscopy. Conclusion: These findings support the potential application of GNR/Alg/PDADMAC as an alternative agent to conventional antiseptics and antibiotics for the eradication of medically important MRSA and MSSA biofilms.


Assuntos
Alginatos , Antibacterianos , Biofilmes , Ouro , Nanotubos , Polietilenos , Compostos de Amônio Quaternário , Staphylococcus aureus , Biofilmes/efeitos dos fármacos , Ouro/química , Ouro/farmacologia , Compostos de Amônio Quaternário/química , Compostos de Amônio Quaternário/farmacologia , Alginatos/química , Alginatos/farmacologia , Nanotubos/química , Animais , Camundongos , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/fisiologia , Antibacterianos/farmacologia , Antibacterianos/química , Polietilenos/química , Polietilenos/farmacologia , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Staphylococcus aureus Resistente à Meticilina/fisiologia , Linhagem Celular , Testes de Sensibilidade Microbiana , Nanopartículas Metálicas/química
11.
J Orthop Surg Res ; 19(1): 259, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659060

RESUMO

PURPOSE: The purpose of the study was to describe a novel growth guidance system, which can avoid metal debris and reduce the sliding friction forces, and test the durability and glidability of the system by in vitro test. METHOD: Two major modifications were made to the traditional Shilla system, including the use of ultra-high molecular weight polyethylene (UHMWPE) gaskets to avoid direct contact between the screw and rod, and polishing the surface of the sliding part of the rod. We tested the durability of the system by a fatigue test, which the samples were test on the MTS system for a 10 million cycle of a constant displacement. Pre and post-testing involved weighing the UHMWPE gaskets and observing the wear conditions. The sliding ability were measured by a sliding displacement test. The maximum sliding displacement of the system was measured after a 300 cycles of dynamic compressive loads in a sinusoidal waveform. RESULTS: After the fatigue test, all the UHMWPE gaskets samples showed some of the fretting on the edge of the inner sides, but its still isolated and avoided the friction between the screws and rods. There was no production of metallic fretting around the sliding screws and rods. The average wear mass of the UHMWPE gaskets was 0.002 ± 0.001 g, less than 1.7% of the original mass. In the sliding test, the novel growth guidance system demonstrated the best sliding ability, with an average maximum sliding distance(AMSD) of 35.75 ± 5.73 mm, significantly better than the group of the traditional Shilla technique(AMSD 3.65 ± 0.46 mm, P < 0.0001). CONCLUSION: In conclusion, we modified the Shilla technique and designed a novel growth guidance system by changing the friction interface of sliding screw and rod, which may significantly reduce the metallic debris and promote spine growth. The fatigue test and sliding dislocation test demonstrated the better durability and glidability of the system. An in vivo animal experiment should be performed to further verify the system.


Assuntos
Teste de Materiais , Polietilenos , Escoliose , Humanos , Teste de Materiais/métodos , Fricção , Parafusos Ósseos , Técnicas In Vitro
12.
Biofabrication ; 16(3)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38574552

RESUMO

The advent of 3D bioprinting technologies in tissue engineering has unlocked the potential to fabricatein vitrotissue models, overcoming the constraints associated with the shape limitations of preformed scaffolds. However, achieving an accurate mimicry of complex tissue microenvironments, encompassing cellular and biochemical components, and orchestrating their supramolecular assembly to form hierarchical structures while maintaining control over tissue formation, is crucial for gaining deeper insights into tissue repair and regeneration. Building upon our expertise in developing competent three-dimensional tissue equivalents (e.g. skin, gut, cervix), we established a two-step bottom-up approach involving the dynamic assembly of microtissue precursors (µTPs) to generate macroscopic functional tissue composed of cell-secreted extracellular matrix (ECM). To enhance precision and scalability, we integrated extrusion-based bioprinting technology into our established paradigm to automate, control and guide the coherent assembly ofµTPs into predefined shapes. Compared to cell-aggregated bioink, ourµTPs represent a functional unit where cells are embedded in their specific ECM.µTPs were derived from human dermal fibroblasts dynamically seeded onto gelatin-based microbeads. After 9 days,µTPs were suspended (50% v/v) in Pluronic-F127 (30% w/v) (µTP:P30), and the obtained formulation was loaded as bioink into the syringe of the Dr.INVIVO-4D6 extrusion based bioprinter.µTP:P30 bioink showed shear-thinning behavior and temperature-dependent viscosity (gel atT> 30 °C), ensuringµTPs homogenous dispersion within the gel and optimal printability. The bioprinting involved extruding several geometries (line, circle, and square) into Pluronic-F127 (40% w/v) (P40) support bath, leveraging its shear-recovery property. P40 effectively held the bioink throughout and after the bioprinting procedure, untilµTPs fused into a continuous connective tissue.µTPs fusion dynamics was studied over 8 days of culture, while the resulting endogenous construct underwent 28 days culture. Histological, immunofluorescence analysis, and second harmonic generation reconstruction revealed an increase in endogenous collagen and fibronectin production within the bioprinted construct, closely resembling the composition of the native connective tissues.


Assuntos
Bioimpressão , Polietilenos , Polipropilenos , Alicerces Teciduais , Humanos , Alicerces Teciduais/química , Bioimpressão/métodos , Poloxâmero , Uridina Trifosfato , Engenharia Tecidual/métodos , Impressão Tridimensional
13.
Mol Med ; 30(1): 52, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641575

RESUMO

BACKGROUND: Skin fibrosis affects the normal function of the skin. TGF-ß1 is a key cytokine that affects organ fibrosis. The latency-associated peptide (LAP) is essential for TGF-ß1 activation. We previously constructed and prepared truncated LAP (tLAP), and confirmed that tLAP inhibited liver fibrosis by affecting TGF-ß1. SPACE peptide has both transdermal and transmembrane functions. SPACE promotes the delivery of macromolecules through the stratum corneum into the dermis. This study aimed to alleviate skin fibrosis through the delivery of tLAP by SPACE. METHODS: The SPACE-tLAP (SE-tLAP) recombinant plasmid was constructed. SE-tLAP was purified by nickel affinity chromatography. The effects of SE-tLAP on the proliferation, migration, and expression of fibrosis-related and inflammatory factors were evaluated in TGF-ß1-induced NIH-3T3 cells. F127-SE-tLAP hydrogel was constructed by using F127 as a carrier to load SE-tLAP polypeptide. The degradation, drug release, and biocompatibility of F127-SE-tLAP were evaluated. Bleomycin was used to induce skin fibrosis in mice. HE, Masson, and immunohistochemistry were used to observe the skin histological characteristics. RESULTS: SE-tLAP inhibited the proliferation, migration, and expression of fibrosis-related and inflammatory factors in NIH-3T3 cells. F127-SE-tLAP significantly reduced ECM production, collagen deposition, and fibrotic pathological changes, thereby alleviating skin fibrosis. CONCLUSION: F127-SE-tLAP could increase the transdermal delivery of LAP, reduce the production and deposition of ECM, inhibit the formation of dermal collagen fibers, and alleviate the progression of skin fibrosis. It may provide a new idea for the therapy of skin fibrosis.


Assuntos
Polietilenos , Polipropilenos , Dermatopatias , Fator de Crescimento Transformador beta , Animais , Camundongos , Bleomicina/efeitos adversos , Colágeno/metabolismo , Fibrose/tratamento farmacológico , Hidrogéis/química , Hidrogéis/farmacologia , Polietilenos/farmacologia , Polipropilenos/farmacologia , Transdução de Sinais , Fator de Crescimento Transformador beta/metabolismo , Fator de Crescimento Transformador beta1/metabolismo , Dermatopatias/induzido quimicamente , Dermatopatias/tratamento farmacológico , Dermatopatias/metabolismo , Proteínas Smad/efeitos dos fármacos , Proteínas Smad/metabolismo , Pele/efeitos dos fármacos , Pele/metabolismo , Pele/patologia
14.
Anal Methods ; 16(19): 3030-3038, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38682263

RESUMO

In this work, a sensitive colorimetric bioassay method based on a poly(adenine) aptamer (polyA apt) and gold nanoparticles (AuNPs) was developed for the determination of aflatoxin B1 (AFB1). The polyA apt, adsorbed on the AuNPs, especially can bind to the analyte while deterring non-specific interactions. This nano aptasensor uses cationic polymer poly(diallyl dimethyl ammonium chloride) (PDDA), as an aggregating agent, to aggregate gold nanoparticles. PolyA apt-decorated gold nanoparticles (AuNPs/polyA apt) show resistance to PDDA-induced aggregation and maintains their dispersed state (red color) with the optical absorbance signal at λ = 520 nm. However, in the presence of AFB1 in the assay solution, the specific aptamer reacts with high affinity and folds into its three-dimensional form. Aggregation of AuNPs induced by PDDA caused their optical signal shift to λ = 620 nm (blue color). AFB1 concentration in the bioassay solution determines the amount of optical signal shift. Therefore, optical density ratio in two wavelengths (A620/520) can be used as a sturdy colorimetric signal to detect the concentration of aflatoxin B1. AFB1 was linearly detected between 0.5 and 20 ng mL-1, with a detection limit of 0.09 ng mL-1 (S/N = 3). The fabricated aptasensor was applied to the detection of AFB1 in real corn samples.


Assuntos
Aflatoxina B1 , Aptâmeros de Nucleotídeos , Colorimetria , Ouro , Nanopartículas Metálicas , Zea mays , Aflatoxina B1/análise , Aflatoxina B1/química , Ouro/química , Colorimetria/métodos , Zea mays/química , Nanopartículas Metálicas/química , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Poli A/química , Limite de Detecção , Contaminação de Alimentos/análise , Compostos de Amônio Quaternário/química , Polietilenos
15.
Mikrochim Acta ; 191(5): 265, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625451

RESUMO

Sleep deprivation (SD) is highly prevalent in the modern technological world. Emerging evidence shows that sleep deprivation is associated with oxidative stress. At the organelle level, the Golgi apparatus actively participates in the stress response. In this study, to determine whether SD and Golgi apparatus stress are correlated, we rationally designed and fabricated a novel Golgi apparatus-targeted ratiometric nanoprobe called Golgi dots for O2·- detection. This probe exhibits high sensitivity and selectivity in cells and brain slices of sleep-deprived mice. Golgi dots can be readily synthesized by coprecipitation of Golgi-F127, an amphiphilic polymer F127 modified with a Golgi apparatus targeting moiety, caffeic acid (CA), the responsive unit for O2·-, and red emissive carbon nanodots (CDs), which act as the reference signal. The fluorescence emission spectrum of the developed nanoprobe showed an intense peak at 674 nm, accompanied by a shoulder peak at 485 nm. As O2·- was gradually added, the fluorescence at 485 nm continuously increased; in contrast, the emission intensity at 674 nm assigned to the CDs remained constant, resulting in the ratiometric sensing of O2·-. The present ratiometric nanoprobe showed high selectivity for O2·- monitoring due to the specific recognition of O2·- by CA. Moreover, the Golgi dots exhibited good linearity with respect to the O2·- concentration within 5 to 40 µM, and the limit of detection (LOD) was ~ 0.13 µM. Additionally, the Golgi dots showed low cytotoxicity and an ability to target the Golgi apparatus. Inspired by these excellent properties, we then applied the Golgi dots to successfully monitor exogenous and endogenous O2·- levels within the Golgi apparatus. Importantly, with the help of Golgi dots, we determined that SD substantially elevated O2·- levels in the brain.


Assuntos
Encéfalo , Ácidos Cafeicos , Polietilenos , Polipropilenos , Privação do Sono , Animais , Camundongos , Complexo de Golgi , Suplementos Nutricionais
16.
Nanoscale Horiz ; 9(5): 863-872, 2024 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-38533738

RESUMO

The behavior of polyelectrolytes in confined spaces has direct relevance to the protein mediated ion transport in living organisms. In this paper, we govern lithium chloride transport by the interface provided by polyelectrolytes, polycation, poly(diallyldimethylammonium chloride) (PDDA) and, polyanion, double stranded deoxyribonucleic acid (dsDNA), in confined graphene oxide (GO) membranes. Polyelectrolyte-GO interfaces demonstrate neuromorphic functions that were successfully applied with nanochannel ion interactions contributed, resulting in ion memory effects. Excitatory and inhibitory post-synaptic currents were tuned continuously as the number of pulses applied increased accordingly, increasing decay times. Furthermore, we demonstrated the short-term memory of a trained vs untrained device in computation. On account of its simple and safe production along with its robustness and stability, we anticipate our device to be a low dimensional building block for arrays to embed artificial neural networks in hardware for neuromorphic computing. Additionally, incorporating such devices with sensing and actuating parts for a complete feedback loop produces robotics with its own ability to learn by modifying actuation based on sensing data.


Assuntos
DNA , Grafite , Polietilenos , Compostos de Amônio Quaternário , Grafite/química , DNA/química , Compostos de Amônio Quaternário/química , Polietilenos/química , Redes Neurais de Computação , Membranas Artificiais , Óxidos/química
17.
ACS Biomater Sci Eng ; 10(5): 3029-3040, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38551901

RESUMO

Polycationic polymers are widely studied antiseptics, and their efficacy is usually quantified by the solution concentration required to kill a fraction of a population of cells (e.g., by Minimum Bactericidal Concentration (MBC)). Here we describe how the response to a polycationic antimicrobial varies greatly among members of even a monoclonal population of bacteria bathed in a single common antimicrobial concentration. We use fluorescence microscopy to measure the adsorption of a labeled cationic polymer, polydiallyldimethylammmonium chloride (PDADMAC, Mw ≈ 4 × 105 g mol-1) and the time course of cell response via a cell permeability indicator for each member of an ensemble of either Escherichia coli, Staphylococcus aureus, or Pseudomonas aeruginosa cells. This is a departure from traditional methods of evaluating synthetic antimicrobials, which typically measure the overall response of a collection of cells at a particular time and therefore do not assess the diversity within a population. Cells typically die after they reach a threshold adsorption of PDADMAC, but not always. There is a substantial time lag of about 5-10 min between adsorption and death, and the time to die of an individual cell is well correlated with the rate of adsorption. The amount adsorbed and the time-to-die differ among species but follow a trend of more adsorption on more negatively charged species, as expected for a cationic polymer. The study of individual cells via time-lapse microscopy reveals additional details that are lost when measuring ensemble properties at a particular time.


Assuntos
Escherichia coli , Pseudomonas aeruginosa , Staphylococcus aureus , Escherichia coli/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Pseudomonas aeruginosa/efeitos dos fármacos , Polietilenos/química , Polietilenos/farmacologia , Compostos de Amônio Quaternário/farmacologia , Compostos de Amônio Quaternário/química , Polieletrólitos/química , Polieletrólitos/farmacologia , Testes de Sensibilidade Microbiana , Antibacterianos/farmacologia , Antibacterianos/química , Antibacterianos/síntese química , Polímeros/farmacologia , Polímeros/química , Microscopia de Fluorescência , Adsorção
18.
Biomacromolecules ; 25(4): 2312-2322, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38456765

RESUMO

Local delivery of pain medication can be a beneficial strategy to address pain management after joint replacement, as it can decrease systemic opioid usage, leading to less side and long-term effects. In this study, we used ultrahigh molecular weight polyethylene (UHMWPE), commonly employed as a bearing material for joint implants, to deliver a wide set of analgesics and the nonsteroidal anti-inflammatory drug tolfenamic acid. We blended the drugs with UHMWPE and processed the blend by compression molding and sterilization by low-dose gamma irradiation. We studied the chemical stability of the eluted drugs, drug elution, tensile properties, and wear resistance of the polymer blends before and after sterilization. The incorporation of bupivacaine hydrochloride and tolfenamic acid in UHMWPE resulted in either single- or dual-drug loaded materials that can be sterilized by gamma irradiation. These compositions were found to be promising for the development of clinically relevant drug-eluting implants for joint replacement.


Assuntos
Artroplastia de Substituição , ortoaminobenzoatos , Teste de Materiais , Polietilenos/química , Analgésicos , Anti-Inflamatórios não Esteroides
19.
Proc Inst Mech Eng H ; 238(4): 438-443, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38439747

RESUMO

With low wear rates shown by contemporary bearing materials of total hip prostheses, the standard deviation of wear rate is relatively high. Therefore, large sample sizes are needed for an adequate power of test. Because wear tests take a long time, it is practical to test several samples simultaneously. A new high-capacity, multidirectional wear test device, called the SuperCTPOD-200, was introduced. A 3 million-cycle wear test with an unprecedented sample size of 200 was performed for VEXLPE. The duration of the test was 6 weeks. The wear factor was normally distributed with a mean ± SD of 1.64 × 10-7 mm3/Nm ± 0.22 × 10-7 mm3/Nm (n = 200). The observation that SD was 13.1% of the mean can be useful in power analyses of future tests with other highly cross-linked polyethylenes. Burnishing was the most typical feature on the worn pins, which was in agreement with clinical findings on retrieved acetabular liners. The present study emphasizes statistics that often plays a minor role only in wear studies.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Teste de Materiais , Óxido de Alumínio , Polietilenos , Falha de Prótese
20.
Water Res ; 254: 121397, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38461599

RESUMO

Municipal wastewater treatment plants (WWTPs) play a crucial role in the collection and redistribution of plastic particles from both households and industries, contributing to their presence in the environment. Previous studies investigating the levels of plastics in WWTPs, and their removal rates have primarily focused on polymer type, size, shape, colour, and particle count, while comprehensive understanding of the mass concentration of plastic particles, particularly those <1 µm (nanoplastics), remains unclear and lacking. In this study, pyrolysis gas chromatography-mass spectrometry was used to simultaneously determine the mass concentration of nine selected polymers (i.e., polyethylene (PE), polypropylene (PP), polystyrene (PS), poly(ethylene terephthalate) (PET), nylon 6, nylon 66, polyvinylchloride (PVC), poly(methyl methacrylate) (PMMA) and polycarbonate (PC)) below 1 µm in size across the treatment processes or stages of three WWTPs in Australia. All the targeted nanoplastics were detected at concentrations between 0.04 and 7.3 µg/L. Nylon 66 (0.2-7.3 µg/L), PE (0.1-6.6 µg/L), PP (0.1-4.5 µg/L), Nylon 6 (0.1-3.6 µg/L) and PET (0.1-2.2 µg/L), were the predominant polymers in the samples. The mass concentration of the total nanoplastics decreased from 27.7, 18 and 9.1 µg/L in the influent to 1, 1.4 and 0.8 µg/L in the effluent, with approximate removal rates of 96 %, 92 % and 91 % in plants A, B and C, respectively. Based on annual wastewater effluent discharge, it is estimated that approximately 24, 2 and 0.7 kg of nanoplastics are released into the environment per year for WWTPs A, B and C, respectively. This study investigated the mass concentrations and removal rates of nanoplastics with a size range of 0.01-1 µm in wastewater, providing important insight into the pollution levels and distribution patterns of nanoplastics in Australian WWTPs.


Assuntos
Caprolactama/análogos & derivados , Polímeros , Poluentes Químicos da Água , Purificação da Água , Águas Residuárias , Microplásticos , Nylons , Pirólise , Cromatografia Gasosa-Espectrometria de Massas , Austrália , Plásticos/análise , Polipropilenos/análise , Polimetil Metacrilato , Polietilenos , Poluentes Químicos da Água/química , Monitoramento Ambiental
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...