Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.915
Filtrar
1.
Acta Odontol Scand ; 83: 392-403, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38895776

RESUMO

OBJECTIVES: To evaluate the current evidence of digital workflow feasibility based on the data acquisition methods and the software tools used to fabricate intraoral prostheses for patients with partial or total maxillary and mandibular defects. MATERIALS AND METHODS: An electronic search was performed in PubMed, SCOPUS, and Web of Science using a combination of relevant keywords: digital workflow, digital designing, computer-assisted design-computer aided manufacturing, 3D printing, maxillectomy, and mandibulectomy. The Joanna Briggs Institute Critical Appraisal Tool was used to assess the quality of evidence in the studies reviewed. RESULTS: From a total of 542 references, 33 articles were selected, including 25 on maxillary prostheses and 8 on mandibular prostheses. The use of digital workflows was limited to one or two steps of the fabrication of the prostheses, and only four studies described a complete digital workflow. The most preferred method for data acquisition was intraoral scanning with or without a cone beam computed tomography combination. CONCLUSION: Currently, the fabrication process of maxillofacial prostheses requires combining digital and conventional methods. Simplifying the data acquisition methods and providing user-friendly and affordable software may encourage clinicians to use the digital workflow more frequently for patients requiring maxillofacial prostheses.


Assuntos
Prótese Maxilofacial , Fluxo de Trabalho , Humanos , Desenho Assistido por Computador , Estudos de Viabilidade , Impressão Tridimensional , Software , Desenho de Prótese
2.
Int J Pharm ; 657: 124181, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38697583

RESUMO

Maxillofacial defects, arising from trauma, oncological disease or congenital abnormalities, detrimentally affect daily life. Prosthetic repair offers the aesthetic and functional reconstruction with the help of materials mimicking natural tissues. 3D polymer printing enables the design of patient-specific prostheses with high structural complexity, as well as rapid and low-cost fabrication on-demand. However, 3D printing for prosthetics is still in the early stage of development and faces various challenges for widespread use. This is because the most suitable polymers for maxillofacial restoration are soft materials that do not have the required printability, mechanical strength of the printed parts, as well as functionality. This review focuses on the challenges and opportunities of 3D printing techniques for production of polymer maxillofacial prostheses using computer-aided design and modeling software. Review discusses the widely used polymers, as well as their blends and composites, which meet the most important assessment criteria, such as the physicochemical, biological, aesthetic properties and processability in 3D printing. In addition, strategies for improving the polymer properties, such as their printability, mechanical strength, and their ability to print multimaterial and architectural structures are highlighted. The current state of the prosthetic retention system is presented with a focus on actively used polymer adhesives and the recently implemented prosthesis-supporting osseointegrated implants, with an emphasis on their creation from 3D-printed polymers. The successful prosthetics is discussed in terms of the specificity of polymer materials at the restoration site. The approaches and technological prospects are also explored through the examples of the nasal, auricle and ocular prostheses, ranging from prototypes to end-use products.


Assuntos
Prótese Maxilofacial , Polímeros , Impressão Tridimensional , Humanos , Polímeros/química , Desenho de Prótese , Desenho Assistido por Computador , Animais , Retenção da Prótese/métodos
3.
J Prosthet Dent ; 131(6): 1253.e1-1253.e34, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38744560

RESUMO

STATEMENT OF PROBLEM: Maxillofacial prosthodontists were advanced digital technology (ADT) adopters early in the new Millennium. The past two decades saw a range of digital enablers emerge including digital imaging (internal and surface), digital surgical planning, digital functional assessment, subtractive and additive manufacturing, navigation, and robotics among others. Artificial Intelligence (AI) is the latest ADT arrival that will be a challenging disruptive technology. ADT has served as a profound change agent in maxillofacial prosthodontics. The intent was to explore the process and level of ADT engagement in maxillofacial prosthodontics. PURPOSE: The purpose was twofold. Firstly, to explore maxillofacial prosthodontic engagement of ADT. Secondly, to develop a discussion document to assist the American Academy of Maxillofacial Prosthetics (AAMP) with establishing a collective awareness and considered opinion on the future of maxillofacial prosthodontics in the digital era. MATERIAL AND METHODS: AAMP member interest in ADT was assessed through analysis of AAMP annual congress programs and publications in the Journal of Prosthetic Dentistry (JPD). The history of the maxillofacial prosthodontic journey to the digital era was undertaken with a selective literature review. The perceptions maxillofacial prosthodontists hold on ADT engagement was assessed through a survey of AAMP members. Developing an understanding of the influence AI was conducted with a review of pertinent literature. RESULTS: From 2011-2020, an annual mean of 38% of papers published in the JPD involved clinical use of ADT. From 2017-2019, 44% of invited presentations at AAMP annual congresses included clinical use of ADT. The journey to the digital era distinguished three periods with formative and consolidation periods influencing the innovation digital era. The AAMP member survey had a 59% response rate and studied 10 domains through 31 questions. Of the respondents, 89% thought ADT important to the future of maxillofacial prosthodontics. CONCLUSIONS: The discussion document will assist the AAMP in developing a collective consciousness and considered opinion on ADT in the future of maxillofacial prosthodontics. Members of the AAMP have a developed interest in clinical applications of ADT. A great challenge is that no formal education, training, or clinical competency requirements for ADT could be identified. Clinical competency requirements are important to prepare maxillofacial prosthodontics for the inevitability of a digital era future. The discussion document poses the fundamental question of whether maxillofacial prosthodontists will remain as passive end users of ADT and AI or will they become engaged knowledge workers that have determined clinical competency in ADT and AI in patient care. Without this knowledge worker role, maxillofacial prosthodontists may experience difficulty being part of the inevitable ADT-AI driven future.


Assuntos
Inteligência Artificial , Prostodontia , Humanos , América do Norte , Tecnologia Digital , Prótese Maxilofacial , Previsões , Desenho Assistido por Computador
4.
Facial Plast Surg Clin North Am ; 32(2): 327-337, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38575290

RESUMO

Prosthetic nasal reconstruction provides a restorative option for patients with nasal defects, and these can be retained with a variety of methods including adhesives and implants. These prostheses can significantly improve appearance, self-esteem, and quality of life for patients and they restore many functions of the external nose. Traditional fabrication methods are often used by the skilled professionals who make these custom prostheses, but digital technology is improving the workflow for design and fabrication of silicone nasal prostheses. Nasal prosthetic reconstruction requires multidisciplinary coordination between surgeons, maxillofacial prosthodontists, anaplastologists, and other members of the healthcare team. Prosthetic treatment can be considered as an alternative to, or an addition to treatment with surgical reconstruction.


Assuntos
Prótese Maxilofacial , Neoplasias Nasais , Humanos , Nariz/cirurgia , Desenho de Prótese , Qualidade de Vida , Próteses e Implantes , Neoplasias Nasais/cirurgia
5.
Rev. Odontol. Araçatuba (Impr.) ; 45(1): 59-64, jan.-abr. 2024. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1553266

RESUMO

Introdução: O tratamento de tumores malignos ou benignos, podem resultar em procedimentos cirúrgicos, como a maxilectomia parcial ou total, gerando comunicação bucosinusal nos pacientes. Uma forma de resolver estas alterações maxilofaciais é através do tratamento reabilitador com próteses obturadoras a fim de restabelecer a função mastigatória, estética, fonética e psicológica. Objetivo: o objetivo deste trabalho foi relatar o caso clínico de um paciente oncológico que foi reabilitado com prótese obturadora devido à maxilectomia por neoplasia maligna de seio maxilar. Relato de caso: Paciente de 62 anos, sexo masculino, procurou atendimento odontológico no Centro de Oncologia Bucal da Universidade Estadual Paulista "Júlio de Mesquita Filho" (UNESP) de Araçatuba ­ SP após a realização de uma maxilectomia parcial com comunicação bucosinusal e foi encaminhado para o Curso de Especialização em Prótese Dentária da Faculdade de Odontologia ­ Unesp/Araçatuba-SP para a reabilitação. Foi proposto, primeiramente a realização da prótese obturadora para fechar a comunicação bucosinusal e uma prótese total inferior para o arco antagonista e, posteriormente, a realização de uma prótese facial. Conclusão: O tratamento reabilitador com próteses obturadoras possui um bom resultado estético e funcional, favorecendo uma melhor função mastigatória e fonética, e melhorando consideravelmente a condição psicológica que é muito afetada nos pacientes submetidos a maxilectomia total ou parcial, sendo necessário uma boa interação com toda a equipe multiprofissional envolvida para que haja um melhor tratamento integrado para a reabilitação e melhora da qualidade de vida(AU)


Introduction: The treatment of malignant or benign tumors can result in surgical procedures, such as partial or total maxillectomy, generating oral communication in patients. One way to resolve these maxillofacial changes is through rehabilitative treatment with obturator prostheses in order to reestablish masticatory, aesthetic, phonetic and psychological function. Objective: the objective of this work was to report the clinical case of a cancer patient who was rehabilitated with an obturator prosthesis due to maxillectomy for malignant neoplasia of the maxillary sinus. Case report: A 62-year-old male patient sought dental care at the Oral Oncology Center of the Universidade Estadual Paulista "Júlio de Mesquita Filho" (UNESP) in Araçatuba ­ SP after undergoing a partial maxillectomy with oral cavity and was referred for the Specialization Course in Dental Prosthesis at the Faculty of Dentistry ­ Unesp/Araçatuba-SP for rehabilitation. It was proposed, firstly, to create an obturator prosthesis to close the bucosinusal communication and a total lower prosthesis for the antagonistic arch and, later, to create a facial prosthesis. Conclusion: Rehabilitative treatment with obturator prostheses has a good aesthetic and functional result, favoring better chewing and phonetic function, and considerably improving the psychological condition that is greatly affected in patients undergoing total or partial maxillectomy, requiring good interaction with the entire the multidisciplinary team involved so that there is better integrated treatment for rehabilitation and improved quality of life


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Obturadores Palatinos , Neoplasias Bucais , Prótese Maxilofacial , Reabilitação Bucal , Procedimentos Cirúrgicos Bucais , Maxila/cirurgia
6.
J Oral Sci ; 66(2): 116-119, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38447982

RESUMO

PURPOSE: This study investigated the color stability of different commercially available silicone materials for facial prostheses upon exposure to everyday beverages. It was hypothesized that the beverages would not alter the color of the silicone under conditions simulating daily exposure. METHODS: Sixty specimens were fabricated using two materials - VST-50 and Silfy - and exposed to commercially available cold mineral water, tea, or coffee. Specimen color was evaluated on days 1 and 15. The color was measured with a spectrophotometer based on CIELab system and color differences were calculated as ΔE. Statistical analysis was performed using the Kruskal-Wallis test and Mann-Whitney U test. RESULTS: The mean ΔE values after 15 days of exposure to mineral water, cold green tea, and coffee were 1.016, 3.480, and 3.636 for VST-50 and 0.440, 0.798, and 1.425 for Silfy, respectively. Both materials showed significant differences in color, and VST-50 showed a greater color change than Silfy, especially for coffee. CONCLUSION: Pigmented silicone elastomers have low color stability, leading to an overall color change in silicone prostheses when exposed to pigmented beverages. Color changes in such prostheses can be mitigated by selecting materials with better color stability to extend their longevity.


Assuntos
Prótese Maxilofacial , Águas Minerais , Elastômeros de Silicone , Cor , Café , Pigmentação em Prótese , Teste de Materiais , Bebidas
7.
J Prosthet Dent ; 131(5): 980.e1-980.e8, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38448355

RESUMO

STATEMENT OF PROBLEM: The choice of cleaning method is an important consideration for lengthening the serviceable time of facial prostheses as microbial organisms and biofilms could degrade facial prostheses and cause skin irritation. Whether microwave disinfection is a suitable cleaning method without degradation of the properties of a prosthesis is unclear. PURPOSE: The purpose of this in vitro study was to measure the color stability of 6 commonly used facial silicone elastomers after microwave disinfection over a simulated 1.5-year period. MATERIAL AND METHODS: Six different facial silicone elastomers: MDX4-4210, MDX4-4210/Type A, M511, A-2186, VST-50, and A-2000 were mixed with intrinsic silicone white opacifier (except for the control group) and subsequently combined with 4 silicone intrinsic pigment color groups: red (R), yellow (Y), burnt sienna (B), and a mixture of R+Y+B (M). The control group was a silicone elastomer without opacifier or pigment. Each of the 30 experimental groups consisted of 5 specimens (N=150). Five specimens were placed in a 250-mL Erlenmeyer flask filled with 160 mL of tap water. Seven flasks were then placed in a 660-W microwave oven. An exposure of 6 minutes was used according to the antimicrobial efficacy of microwave disinfection protocol on facial silicone prostheses with a final water temperature of 60 °C for 18 times (simulating 1.5 years of microwave disinfection with one 6-minute exposure monthly). A spectrophotometer was used to measure reflectance color change values (∆E). Color differences were calculated following CIELab (∆E*ab) and CIEDE2000 (∆E00) formulae. ∆E*ab and ∆E00 were statistically analyzed by a linear mixed effects model with 3 factors (silicone type, color shade, and time) using the R Statistical software program (α=.05). RESULTS: Both ∆E*ab and ∆E00 of all silicone elastomers studied were less than the visual perceptibility thresholds (∆E*ab<1.1 and E00<0.7) and were considered clinically acceptable (∆E*ab<3.0 and E00<2.1) after the 1.5-year simulation of microwave disinfection. Yellow and blue pigments had more effect on MDX4-4210 and M511, while red pigment had more effect on MDX4-4210, MDX4-4210/Type A, and M511 (P<.05). Nevertheless, the values were still below the perceptibility threshold (∆E*ab≤1.0 and E00<0.6). CONCLUSIONS: All 6 facial silicone elastomers maintained clinically acceptable color after 18 months of exposure to microwave disinfection.


Assuntos
Cor , Desinfecção , Prótese Maxilofacial , Micro-Ondas , Elastômeros de Silicone , Micro-Ondas/uso terapêutico , Desinfecção/métodos , Elastômeros de Silicone/química , Pigmentação em Prótese , Humanos , Técnicas In Vitro , Teste de Materiais , Dimetilpolisiloxanos
8.
BMC Oral Health ; 24(1): 403, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553697

RESUMO

BACKGROUND: Implantology, as a recognized therapeutic approach, is gaining prominence. The decision-making process and success of implant therapy are closely linked to patient knowledge and expectations. This study aims to explore the association between age and knowledge regarding oral implants. METHODS: Participants were categorized into three age groups (ag): ag 1 (35-44 years), ag 2 (65-74 years), and ag 3 (75 years and older). A total of 400 participants per age group were randomly selected using data from the residents' registration office of Berlin, Germany. Structured telephone interviews were conducted between 2016 and 2017, employing a 67-item questionnaire covering awareness, information level, cost estimation, attitudes, and experiences with oral implants. RESULTS: Despite a low overall knowledge level across all age groups, there was no significant correlation between age and knowledge about oral implants. Awareness increased with age. Information sources varied, with friends, acquaintances, and dentists playing key roles. Participants expressed diverse opinions on implants, with durability and stability identified as crucial characteristics. Significant differences in knowledge were observed between age groups regarding awareness, information sources, and perceptions of dentists offering implants. CONCLUSIONS: The study suggests a need for targeted educational programs, emphasizing age-appropriate information sources to enhance health literacy in oral implantology, particularly among older individuals. Educating physicians on oral implant basics is also crucial. Implementing these measures could empower individuals to make informed decisions about oral implant treatment, thereby contributing to improved oral health outcomes.


Assuntos
Implantes Dentários , Letramento em Saúde , Prótese Maxilofacial , Humanos , Conhecimentos, Atitudes e Prática em Saúde , Inquéritos e Questionários , Adulto , Pessoa de Meia-Idade , Idoso , Distribuição Aleatória
9.
J Long Term Eff Med Implants ; 34(3): 43-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38505893

RESUMO

The aim of this systematic review was to identify and analyze the findings of various studies that analyzed the changes in the color stability of maxillofacial prosthetic materials after the addition of various colorants and nanoparticles and assess the change in color after being subjected to either natural or artificial accelerated aging as well as outdoor aging. This systematic review was conducted in accordance with the guidelines of transparent reporting of systematic reviews and meta-analysis (PRISMA Statement). The primary objective of this systematic review was to evaluate the color stability of maxillofacial prosthesis. The secondary objective was to assess the effect of various colorants; pigments; opacifiers; UV absorbers-such as inorganic colorants (dry earth pigments); metal oxides; and organic colorants. The time period of the included studies extended from 2013 to 2023. Electronic database search identified a total of 217 studies. Ten studies were included to meet the research question. All 10 included studies analyzed the effect of various colorants and their exposure to various aging and weathering conditions. It was found that various pigments and nanoparticles had an effect on the color stability. Also weathering and aging conditions had a direct effect on the color stability as well. In terms of disinfection, although there was not much color difference observed, highest change in color stability was observed when rubbing or brushing of the prosthesis was carried out. In conclusion, the color stability of maxillofacial prosthetics is a critical factor that influences both patient satisfaction and the overall cosmetic look. The potential of pigments and nanoparticles to enhance the color stability of silicone-based maxillofacial prosthesis has received much research. By avoiding color fading and discoloration brought on by environmental variables including UV radiation, aging, and chemical exposure, the inclusion of various pigments and nanoparticles has been demonstrated to improve the color stability of silicone maxillofacial prostheses.


Assuntos
Prótese Maxilofacial , Pigmentação em Prótese , Humanos , Elastômeros de Silicone , Cor , Próteses e Implantes , Teste de Materiais
11.
J Prosthet Dent ; 131(2): 340.e1-340.e6, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38212157

RESUMO

STATEMENT OF PROBLEM: Part 1 of this 2-part study determined that microwave disinfection did not degrade the color stability of facial silicone prostheses. However, investigations on the effects of microwave disinfection on the mechanical properties of different silicone elastomers are lacking. PURPOSE: The purpose of this in vitro study was to examine the mechanical properties of commonly used colored facial silicone elastomers before and after microwave disinfection over a simulated 1.5-year period. MATERIAL AND METHODS: Six commonly used facial silicone elastomers: MDX4-4210, MDX4-4210/Type A, M511, A-2186, VST-50, and A-2000 were combined with functional intrinsic silicone pigments and opacifier (red, yellow, blue, and white). A total of 288 specimens were fabricated (n=12). Half of the specimens were tested for mechanical properties as the baseline, while the other specimens were tested after microwave disinfection. Microwave disinfection was performed with 660 W, 6 minutes of exposure time, and microwaved for 18 cycles to simulate 1.5 years of usage (one 6-minute exposure monthly). For mechanical property testing, all specimens were tested for tensile strength and percentage elongation (ASTM D412), tear strength (ASTM D624), and hardness (ASTM D2240). For each property, a 2-way ANOVA (silicone type and microwave disinfection factors) and Tukey multiple comparison test were performed using the R statistical software program (α=.05). RESULTS: Following microwave disinfection, tensile strength and percentage elongation of A-2000 increased significantly (P<.05). MDX4-4210, MDX4-4210/Type A, and A-2000 showed significant increases in their hardness (P<.001). Tear strength also increased significantly for MDX4-4210 and VST-50 (P<.05). Among the materials tested (ranked from highest to lowest value,=not statistically significant different), for tensile strength, VST-50>A-2186=A-2000>MDX4-4210/Type A=M511=MDX4-4210 (P<.05). For percentage elongation, VST-50>MDX4-4210/Type A>A-2186>M511=A-2000=MDX4-4210=M511 (P<.05). For hardness, A-2000=A-2186>M511=VST-50>MDX4-4210>MDX4-4210/Type A (P<.05). For tear strength, VST-50>A-2186>A-2000>M511>MDX4-4210/Type A=MDX4-4210 (P<.05). CONCLUSIONS: Overall, the mechanical properties of all the silicones tested were not adversely affected by microwave disinfection. VST-50 showed the best mechanical properties among the materials tested both before and after microwave disinfection. Microwave energy is a safe method of disinfecting the silicone elastomers tested in this study.


Assuntos
Implantes Dentários , Dimetilpolisiloxanos , Prótese Maxilofacial , Elastômeros de Silicone , Desinfecção , Teste de Materiais , Micro-Ondas/uso terapêutico , Resistência à Tração
12.
Braz. j. oral sci ; 23: e249184, 2024. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1553451

RESUMO

Aim: This study aimed to review the scientific literature to describe the main care and hygiene protocols for different types of maxillofacial prostheses (MFP). Methods: A bibliographic search on the PubMed / Medline database using the following keywords: ["maxillofacial prosthesis" OR "ocular prostheses" OR "palatal obturators"] AND ["Cleaning" OR "disinfection"] AND ["care"] AND ["color stability"] OR ["denture cleansers" OR "cleansing agents"]. Articles addressing materials, cleaning and disinfection protocols, and care related to MFP were included. The following exclusion criteria were applied: no adequate methodology, incompatibility with the area of interest, and unavailability for reading in full. Results: The papers were grouped into the following topics: facial prostheses, ocular prostheses, maxillofacial intraoral prostheses, and retention systems. Conclusion: Despite the MFP changes over time, its degradation decreases upon following the recommendations and post-adaptation care. The guidelines for cleaning and disinfection must be individualized to guarantee the longevity of the prosthesis and the patient health


Assuntos
Obturadores Palatinos , Prótese Ossicular , Desinfecção , Higiene , Implante de Prótese Maxilofacial , Prótese Maxilofacial
13.
J Prosthet Dent ; 131(2): 332-339, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38161076

RESUMO

STATEMENT OF PROBLEM: Color matching and marginal integrity are major challenges when providing extraoral maxillofacial prostheses. Which of the color and marginal harmony features are more important for the extraoral prostheses to be inconspicuous is unclear. Studies on the perception of these prostheses with objective evaluation criteria are lacking. PURPOSE: The purpose of this observational study was to investigate the significance of color mismatch and conspicuous marginal adaptation in the perception of extraoral maxillofacial prostheses using eye-tracking technology. The secondary aim was to evaluate the perception of extraoral maxillofacial prostheses with regard to the observers' sex. MATERIAL AND METHODS: Twenty-seven face images, in 3 groups, representing well-fitting orbital prostheses with a color mismatch (IC), prostheses with a good color match but distinct marginal adaptation (IM), and symmetrical face images, were viewed for 5 seconds by 52 laypeople. Time to first fixation (TFF), fixation duration (FD), and fixation count (FC) at defined areas of interest were recorded and analyzed by an eye-tracking device. Because of the nested structure of data, a sex- and age-adjusted random intercept linear mixed effects model was used to assess the difference between IC, IM, and SI. Bonferroni corrected P values were used for pairwise comparisons. The difference between observers' sex was evaluated with random intercept mixed model by adjusting for age for each image. For repeated measurement analysis, the lm4, lmerTest, and emmeans libraries in R version 4.3.1 (R Foundation for Statistical Computing) were used (α=.05 for all tests). RESULTS: Significant differences were found between the symmetrical image group and other study groups at the facial prosthesis region in all parameters (each P<.001). Observers first focused on the facial prostheses in IC (0.72 seconds) and in IM (0.789 seconds). Longer fixation durations, 1.909, 1.989 seconds for IC and IM (PIC<.001, PIM<.001), respectively, and a higher fixation count for IC (5.28) (P<.001) and for IM (5.45) (P<.001) were recorded on facial prostheses compared with other areas of interest. Women were more focused on the prosthesis than men in the IC and IM groups considering FD (PIC=.003, PIM<.001) and FC values (PIC=.016, PIM<.001, PSI<.001). Fixation duration for women and men was 2.097 seconds and 1.739 seconds in the IC group, 2.219 seconds and 1.78 seconds in the IM group, and 1.364 seconds and 1.222 seconds in the SI group, respectively. CONCLUSIONS: Since the color mismatch and distinct marginal adaptation of maxillofacial prostheses were recognized using eye-tracking technology, both features appeared to be equally significant to be considered in fabrication procedures.


Assuntos
Implantes Dentários , Prótese Maxilofacial , Masculino , Humanos , Feminino , Tecnologia de Rastreamento Ocular , Face , Percepção
15.
Stomatologiia (Mosk) ; 102(6): 62-67, 2023.
Artigo em Russo | MEDLINE | ID: mdl-37997315

RESUMO

This review presents an analysis of domestic and foreign literature on the issues of fixation of facial epitheses and combined maxillofacial prostheses, such as the use of craniofacial implants installed in the zygomatic bone, brow arches, orbital walls, mastoid process of the temporal bone with beam or magnetic beam fixation systems. The advantages and disadvantages of such fastening systems are described. The analysis and systematization of available data on medical adhesive compositions that can be used in maxillofacial prosthetics to hold facial epitheses has been carried out. Much attention is paid to the chemical composition of pressure-sensitive adhesives, water-based and silicone-based. Examples of such compositions are given. The physicochemical properties of medical adhesive systems that cause adhesive-cohesive interaction are described. This review presents the results of comparative studies to assess the fixing properties of various adhesives, as well as to study the formation of biofilm on the surfaces of prostheses and skin when using different adhesives.


Assuntos
Implantes Dentários , Prótese Maxilofacial , Humanos , Cimentos Dentários , Face/cirurgia , Silicones , Adesivos/química
16.
J Indian Prosthodont Soc ; 23(4): 401-404, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37861619

RESUMO

Acid attack is a form of violent assault involving the act of throwing acid or any corrosive substance such as sulfuric acid, nitric acid, and hydrochloric acid with the intention to disfigure, maim, torture, or kill. A combination of surgical intervention along with prosthetic management using maxillofacial prosthesis serves a good treatment modality for rehabilitation in such cases. The advent of technological advancements has made the rehabilitation procedure easier, faster, and comfortable both for the patient and prosthodontist.


Assuntos
Cicatriz , Prótese Maxilofacial , Humanos , Queimaduras Químicas , Ácidos , Estereolitografia , Silicones
17.
Int J Oral Maxillofac Implants ; 38(suppl): 37-45, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37436948

RESUMO

Purpose: To quantify the cumulative oral implant survival rates and changes in radiographic bone levels based on the configuration of the implant-abutment connection type over time. Materials and Methods: An electronic literature search was conducted in four databases (PubMed/MEDLINE, Cochrane Library, Web of Science, and Embase), and records were refereed by two independent reviewers based on the inclusion criteria. Data from included articles were grouped by implant-abutment connection type into four categories ([1] external hex; [2] bone level, internal, narrow cone < 45 degrees; [3] bone level, internal wide cone ≥ 45 degrees or flat; and [4] tissue level) and duration of follow-up (short-term 1 to 2 years, mid-term 2 to 5 years, and long-term > 5 years). Meta-analyses were performed for cumulative survival rate (CSR) and changes in marginal bone level (ΔMBL) from baseline (loading) to last reported follow-up. Studies were split or merged as appropriate based on the implants and follow-up duration in the study and trial design. The study was compiled under PRISMA 2020 guidelines and registered in the PROSPERO database. Results: A total of 3,082 articles were screened. Full-text review of 465 articles resulted in a total of 270 articles (representing 16,448 subjects with 45,347 implants) included for quantitative synthesis and analysis. Mean ΔMBL (95% CI) was as follows: short-term external hex = 0.68 mm (0.57, 0.79); short-term bone level, internal, narrow cone < 45 degrees = 0.34 mm (0.25, 0.43); short-term bone level, internal wide cone ≥ 45 degrees = 0.63 mm (0.52, 0.74); short-term tissue level = 0.42 mm (0.27, 0.56); mid-term external hex = 1.03 mm (0.72, 1.34); mid-term bone level, internal, narrow cone < 45 degrees = 0.45 mm (0.34, 0.56); mid-term bone level, internal wide cone ≥ 45 degrees = 0.73 mm (0.58, 0.88); mid-term tissue level = 0.4 mm (0.21, 0.61); long-term external hex = 0.98 mm, 0.70, 1.25); long-term bone level, internal, narrow cone < 45 degrees = 0.44 mm (0.31, 0.57); long-term bone level, internal wide cone ≥ 45 degrees = 0.95 mm (0.68, 1.22); and long-term tissue level = 0.43 mm (0.24, 0.61). CSRs (95% CI) were: short-term external hex = 97% (96%, 98%); short-term bone level, internal, narrow cone < 45 degrees = 99% (99%, 99%); short-term bone level, internal wide cone ≥ 45 degrees = 98% (98%, 99%); short-term tissue level = 99% (98%, 100%); mid-term external hex = 97% (96%, 98%); mid-term bone level, internal, narrow cone < 45 degrees = 98% (98%, 99%); mid-term bone level, internal wide cone ≥ 45 degrees = 99% (98%, 99%); mid-term tissue level = 98% (97%, 99%); long-term external hex = 96% (95%, 98%); long-term bone level, internal, narrow cone < 45 degrees = 98% (98%, 99%); long-term bone level, internal wide cone ≥ 45 degrees = 99% (98%, 100%); and long-term tissue level = 99% (98%, 100%). Conclusion: The configuration of the implant-abutment interface has a measurable effect on the ΔMBL over time. These changes can be observed over a period of at least 3 to 5 years. At all measured time intervals, similar ΔMBL was noted for external hex and internal wide cone ≥ 45-degree connections, as were internal, narrow cone < 45-degree and tissue-level connections.


Assuntos
Implantes Dentários , Prótese Maxilofacial , Humanos , Taxa de Sobrevida
18.
J Prosthodont ; 32(7): 553-559, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37038304

RESUMO

Gunshot wounds in the maxillofacial region may cause serious defects that result in functional and esthetic disabilities. A 14-year-old male patient was referred to the prosthodontics clinic for provisional prosthetic restoration 5 months after an injury involving the midline midfacial region. An interim extraoral silicone maxillofacial prosthesis (MFP), also known as an epithesis, replacing the nose and upper lip, was fabricated to enhance appearance and speech intelligibility. The effect of the prosthesis insertion on speech outcome was assessed over 6 months. Blood pulse oxygen saturation levels and heart rate were monitored to assess ventilation following the prosthesis insertion. Results of the Assessment of Articulation Subtest revealed the patient produced the target speech sounds of 31 more words correctly at 6 months follow-up. Bilabial, labiodental, and postalveolar speech sounds in the phonetic inventory improved. Fabrication of an extraoral silicone MFP, modifying substructure design, and prosthesis usage over time contributed to the significant enhancement of speech intelligibility and did not significantly change the blood pulse oxygen saturation levels and heart rate. It led to an improvement in overall aesthetic outcomes and was a useful tool for the patient's social integration.


Assuntos
Implantes Dentários , Prótese Maxilofacial , Ferimentos por Arma de Fogo , Masculino , Humanos , Adolescente , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/cirurgia , Estética Dentária , Inteligibilidade da Fala , Silicones , Desenho de Prótese
19.
Rev. Odontol. Araçatuba (Impr.) ; 44(1): 47-52, jan.-abr. 2023.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1427917

RESUMO

A odontologia reabilitadora tem como um dos seus ramos a especialidade de Prótese Bucomaxilofacial (PBMF), que visa restaurar ou substituir estruturas perdidas na região facial e no sistema estomatognático artificialmente, podendo ser ou não removidos pelo paciente. O presente trabalho objetiva revisar a leitura a respeito da reabilitação com PBMF e a sua aplicabilidade na clínica odontológica. Os indivíduos com alguma perda de estrutura na região de cabeça e pescoço, devido a traumas físicos e/ou químicos, defeitos congênitos, doenças autoimunes, neoplasias, infecções e parasitas, são pacientes para os quais há a indicação da reposição da parte ausente. As reconstruções podem ser perdas intraorais (área da maxila, mandíbula), extraorais (oculopalpebral, ocular, nasal, facial extensa e auricular) ou conjugadas. Esse é um trabalho multidisciplinar, com especialistas de áreas abrangentes e todos os especialistas trabalham de forma conjunta. Pode-se concluir que, embora seja uma das especialidades mais nobres da odontologia, ainda é muito desconhecida por parte dos estudantes e profissionais das áreas da saúde e são próteses absolutamente fundamentais para a reabilitação e qualidade de vida dos indivíduos que tem a necessidade do uso da prótese PBMF(AU)


Rehabilitating dentistry has as one of its branches the specialty of Oral and Maxillofacial Prosthesis (PBMF), which aims to restore or replace structures lost in the facial region and in the stomatognathic system artificially, which may or may not be removed by the patient. The present study aims to review the reading about rehabilitation with PBMF and its applicability in dental clinic. Individuals with some loss of structure in the head and neck region, due to physical and/or chemical trauma, birth defects, autoimmune diseases, neoplasms, infections and parasites, are patients in whom there is an indication for replacement of the absent part. Reconstructions can be intraoral (maximal area, mandible), extraoral (oculopalpebral, ocular, nasal, extensive facial and auricular) or conjugated losses. It is a multidisciplinary work, with specialists from the comprehensive areas and that all specialists work together. It can be concluded that although it is one of the noblest specialties of dentistry, it is still very unknown to students and health professionals, and they are absolutely fundamental prostheses for the rehabilitation and quality of life of individuals who need the use the PBMFprosthesis(AU)


Assuntos
Cabeça/anormalidades , Prótese Maxilofacial , Pescoço/anormalidades , Qualidade de Vida , Reabilitação , Doenças Autoimunes , Anormalidades Congênitas , Sistema Estomatognático/lesões , Reconstrução Mandibular , Cirurgiões Bucomaxilofaciais , Neoplasias
20.
Bull Tokyo Dent Coll ; 64(1): 31-37, 2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36792151

RESUMO

This report describes the case of a 68-year-old man who visited our department complaining of poor denture retention and difficulty masticating due to damage to the retainer of a maxillary obturator. The patient had never been satisfied with the fit of this prosthesis, which had been placed two years earlier. The obturator and the mucosal surface of the denture base were incompatible, which had caused the retainer to detach. The maxillary defect was categorized as H3S0D0T0 according to the HS classification. The diagnosis was a masticatory disorder due to a damaged retainer and an incompatible denture base. Optical impressions and occlusal records were taken and a maxillary obturator fabricated using a CAD/CAM system. Dental CAD software was used to design and complete the tooth arrangement. The CAM system was used to mill a polyetherketoneketone disc based on the obtained data and composite resin used to face the teeth and gingiva. The maxillary obturator was placed after only three visits, spanning from impression taking to denture completion. The use of digital data allowed the time to denture completion to be shortened in addition to the number of hospital visits to be reduced. Compared to conventional impression taking, optical impressions also prevent discomfort, decreasing stress for the patient.


Assuntos
Implantes Dentários , Prótese Maxilofacial , Masculino , Humanos , Idoso , Polímeros , Benzofenonas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...