Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.230
Filtrar
1.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38814808

RESUMO

OBJECTIVES: The aim of this study was to evaluate the outcomes of transposition of the omentum into the mediastinum to support the replacement of infected aortic grafts or to cover infected aortic grafts that are not amenable for surgical replacement. METHODS: All patients with thoracic aortic graft infections who underwent mediastinal transposition of the omentum at our institution between 2005 and 2023 were included in this study. Mediastinal transposition of the omentum was performed either after replacement of the infected graft ('curative concept') or solely as bailout procedure by wrapping the infected graft ('palliative concept'). The diagnosis, including computed tomography scans during follow-up, was made according to the criteria of the Management of Aortic Graft Infection Collaboration. RESULTS: The patient cohort consisted of 31 patients. Both in-hospital and 1-year mortality were 0% (n = 0) for the curative concept (n = 9) compared to 23% (n = 5) and 41% (n = 9) for the palliative concept (n = 22), respectively. There was no graft infection-associated death or recurrence of infection after 3 years in the curative group. Survival was 52% at 3 years in the palliative group, with freedom of infection in 59% of the patients (n = 13). CONCLUSIONS: Transposition of the omentum and wrapping of the infected aortic prosthetic graft is a useful bailout strategy for patients who are ineligible for replacement of an infected aortic graft. However, mortality stays high. For radical treatment of aortic graft infections, it may prove an effective supportive therapy and represents an important tool in the armamentarium of cardiac surgeons.


Assuntos
Aorta Torácica , Aorta , Prótese Vascular , Mediastino , Omento , Infecções Relacionadas à Prótese , Humanos , Omento/transplante , Omento/cirurgia , Masculino , Feminino , Infecções Relacionadas à Prótese/cirurgia , Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Aorta/cirurgia , Mediastino/cirurgia , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Adulto , Tomografia Computadorizada por Raios X
2.
Ugeskr Laeger ; 186(15)2024 Apr 08.
Artigo em Dinamarquês | MEDLINE | ID: mdl-38708698

RESUMO

Due to degeneration, homografts were since the 1950s only used strictly for replacement of complex arterial segments and lesions incl. the aortic valve, replacement of infected arterial prostheses, and vascular access for patients on haemodialysis. During the 1990s, rate-differentiated freezing methods and anti-crystallization agents proved to prevent crystallisation, and more widespread use with expanded indications incl. coronary and lower limb bypasses began justified by promising midterm results. In 2021, the first Scandinavian homograft biobank was founded in Odense in Denmark. This review summarises the history and the experiences from this biobank.


Assuntos
Criopreservação , Humanos , Aloenxertos , Prótese Vascular/efeitos adversos , Dinamarca
3.
Expert Rev Med Devices ; 21(5): 391-398, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38629872

RESUMO

INTRODUCTION: Endovascular treatment of type B aortic dissections (TBAD) has currently acquired a primary therapeutic role when anatomically feasible. The main issue with thoracic endovascular aortic repair (TEVAR) for aortic dissection is the actual nature of the aortic wall, which is structurally compromised and more fragile. Indeed, a wealth of data have shown that TEVAR for TBAD will lead, in a substantial proportion of cases, to a device-related adverse event named distal stent-graft induced new entry (dSINE). AREAS COVERED: Currently available aortic stent-grafts have not been specifically devised for the treatment of aortic dissection. A novel dissection specific stent-graft (DSSG) was developed, which is a custom-made device based on the Zenith Alpha Thoracic platform (Cook Medical). The DSSG has several unique properties that, in principle, make its use optimal in TBAD patients. EXPERT OPINION: TEVAR in the setting of aortic dissections remains technically challenging. The occurrence of dSINE represents a unique complication in this scenario and may lead to high rates of aortic-related adverse events and need for secondary interventions. The use of a novel custom-made DSSG in the setting of chronic TBAD has been proven to be safe, feasible and effective. However, even this approach may fail to completely prevent dSINE formation.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Procedimentos Endovasculares , Stents , Humanos , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Animais , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos
4.
Clin Infect Dis ; 78(6): 1391-1392, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38635420

RESUMO

Vascular graft infection (VGI) is one of the most serious complications following arterial reconstructive surgery. VGI has received increasing attention over the past decade, but many questions remain regarding its diagnosis and management. In this review, we describe our approach to VGI through multidisciplinary collaboration and discuss decision-making for challenging presentations. This document will concentrate on VGI that impacts both aneurysms and pseudoaneurysms excluding the ascending thoracic aorta.


Assuntos
Procedimentos de Cirurgia Plástica , Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Procedimentos de Cirurgia Plástica/efeitos adversos , Prótese Vascular/efeitos adversos , Equipe de Assistência ao Paciente , Enxerto Vascular/efeitos adversos
5.
Clin Infect Dis ; 78(6): e69-e80, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38656065

RESUMO

Vascular graft infection (VGI) is one of the most serious complications following arterial reconstructive surgery. VGI has received increasing attention over the past decade, but many questions remain regarding its diagnosis and management. In this review, we describe our approach to VGI through multidisciplinary collaboration and discuss decision making for challenging presentations. This review will concentrate on VGI that impacts both aneurysms and pseudoaneurysms excluding the ascending thoracic aorta.


Assuntos
Procedimentos de Cirurgia Plástica , Infecções Relacionadas à Prótese , Humanos , Procedimentos de Cirurgia Plástica/métodos , Procedimentos de Cirurgia Plástica/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Prótese Vascular/efeitos adversos , Equipe de Assistência ao Paciente , Falso Aneurisma/cirurgia , Falso Aneurisma/etiologia , Artérias/cirurgia
6.
Kyobu Geka ; 77(2): 136-139, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459863

RESUMO

A 67-year-old male was admitted to our hospital for sudden onset chest pain and hoarseness. He underwent 2-debranching thoracic endovascular aortic repair for a ruptured aortic arch aneurysm four years prior. However, computed tomography (CT) revealed an aneurysmal rerupture due to a typeⅠa endoleak. We performed partial arch replacement with uncovered stent removal under intermittent hypothermic circulatory arrest. We needed to be more careful than usual open heart surgery because a non-anatomical bypass procedure was performed. The surgery was successful without any major complications, and the patient was discharged on the 23th postoperative day. Reinterventions post-endovascular repair are sometimes difficult;thus, open surgery could be useful for arch replacement.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Correção Endovascular de Aneurisma , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Resultado do Tratamento , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Estudos Retrospectivos
7.
BMC Cardiovasc Disord ; 24(1): 182, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532333

RESUMO

OBJECTIVE: To evaluate the early and mid-term outcomes of open repair in patients with thoracoabdominal aortic aneurysm (TAAA) after thoracic endovascular aortic repair (TEVAR). METHODS: This was a retrospective single center study. Data were retrospectively collected and analyzed for consecutive patients undergoing open TAAA repair (TAAAR) after TEVAR from November 2016 to June 2021. Indications for TAAAR included aneurysm progression due to endoleak, persisted false lumen perfusion, proximal/distal disease progression, and aorta rupture. The risk factor of operative mortality was analyzed by multivariable logistic regression model and the survival was evaluated by Kaplan-Meier. RESULTS: Sixty-three patients who met the inclusion criteria for the study were identified. The mean age at TAAAR was 41 ± 12 years and 43 (68.3%) were male. Marfan syndrome (MFS) was presented in 39 patients (61.9%). 60 (95.2%) patients presented with post-dissection aneurysm and 3 (4.8%) patients with degenerative aneurysm. The extent of TAAA was Crawford I in 9 (14.3%), II in 22 (34.9%), III in 23 (36.5%), and IV in 9 (14.3%). Emergent TAAAR was done in 10 (15.9%) patients, and deep hypothermic circulatory arrest was used in 22 (34.6%). Endograft was explanted in 31 (49.2%). Operative mortality was 11 (17.5%). Stroke, paraplegia, and acute kidney failure occurred in 5 (7.9%), 7 (11.1%), and 6 (9.5%) patients, respectively. Pulmonary complications occurred in 19 (30.2%) patients. The estimated survival was 74.8 ± 4.9% at 5 years. Late reoperations were performed in 2 patients at 2.5 years and 1.3 years, respectively. CONCLUSIONS: In this series of TAAA after TEVAR, TAAAR was related with a high risk of operative mortality and morbidity and the midterm outcomes represented a durable treatment and were respectable.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Feminino , Correção Endovascular de Aneurisma , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Aneurisma da Aorta Torácica/cirurgia , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias
9.
Eur J Vasc Endovasc Surg ; 67(6): 997-1005, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38341175

RESUMO

OBJECTIVE: This study examines outcome and durability of physician made bovine pericardial tube grafts in aortic infections in all anatomical locations. METHODS: This was a retrospective and prospective international multicentre study. Peri-operative and long term outcomes of patients undergoing in situ aortic reconstruction for native or graft infections with physician made bovine pericardial tube grafts between January 2008 and December 2020 in four European tertiary referral centres were analysed. The primary endpoint was recurrent aortic infection. Secondary endpoints were persistent infection, aortic re-operation for infection, graft related complications, and death. RESULTS: One hundred and sixty eight patients (77% male, mean age 67 ± 11 years) were identified: 38 (23%) with native and 130 (77%) with aortic graft infection. The thirty day mortality rate was 15% (n = 26) overall, 11% (n = 4), and 17% (n = 22) for native and aortic graft infections, respectively (p = .45). Median follow up was 26 months (interquartile range [IQR] 10, 51). Estimated survival at one, two, three, and five years was 64%, 60%, 57%, and 50%, and significantly better for native (81%, 77%, 77%, and 69%) than for graft infections (58%, 55%, 51%, and 44%; p = .011). Nine patients (5.3%) had persistent infection and 10 patients (6%) had aortic re-infection after a median of 10 months (IQR 5, 22), resulting in an estimated freedom from re-infection at one, two, three, and five years of 94%, 92%, 90%, and 86%. Estimated freedom from graft complications at one, two, three, and five years was 91%, 89%, 87%, and 87%. CONCLUSION: This multicentre study demonstrates low re-infection rates when using physician made bovine pericardial tube grafts, comparable to those of other biological grafts. The rate of graft complications, mainly anastomotic aneurysms and stenoses, was low, while graft degeneration was absent. Physician made bovine pericardial tube grafts are an excellent tool for in situ reconstruction in the setting of native aortic infection or aortic graft infection.


Assuntos
Bioprótese , Implante de Prótese Vascular , Prótese Vascular , Pericárdio , Infecções Relacionadas à Prótese , Reoperação , Humanos , Masculino , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/microbiologia , Idoso , Feminino , Prótese Vascular/efeitos adversos , Bovinos , Pericárdio/transplante , Estudos Retrospectivos , Pessoa de Meia-Idade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Europa (Continente) , Bioprótese/efeitos adversos , Reoperação/estatística & dados numéricos , Estudos Prospectivos , Animais , Resultado do Tratamento , Recidiva , Desenho de Prótese , Aorta/cirurgia , Fatores de Tempo
10.
Int Angiol ; 43(2): 255-261, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38345547

RESUMO

BACKGROUND: In this study, the early and mid-term outcomes of Omniflow® II (LeMaitre Vascular, Inc., Burlington, MA, USA) biosynthetic graft in redo surgery in patients with critical limb-threatening ischemia (CLTI) with no available autologous vein material were investigated with the aim to compare the outcomes obtained in "de novo" surgery versus redo surgery. METHODS: From January 2018 until December 2022, data of CLTI patients from 18 centers in Italy with no autologous vein material underwent infrainguinal bypass with Omniflow® II biosynthetic graft were collected. Thirty-day outcome measures including intraoperative technical success, major morbidity, mortality, and graft patency were assessed and compared. At two-year follow-up, estimated outcomes of survival, primary patency, primary assisted patency, secondary patency, freedom from reintervention, and amputation-free survival were analyzed using Kaplan-Meier curves and compared between groups using the log-rank test. RESULTS: In the study period 119 CLTI patients had an infrainguinal bypass with Omniflow® II biosynthetic graft. Seventy-seven patients (64.7%) underwent bypass as "de novo" treatment (group de novo), whilst in the remaining 42 patients (35.3%) the procedure was performed as redo surgery due to occlusion and/or infection of a previous bypass graft (group redo). Two groups were homogeneous in terms of demographic, clinical, and morphological data. In group redo explantation of an infected prosthetic graft was needed in 4 cases (9.5%). Intraoperative technical success was achieved in all cases in both groups. At 30 days, the overall patency rate did not differ between the two groups (69/77, 89.6%, group de novo vs. 35/42, 83.3%, group redo; P=0.24), whilst in group redo limb loss was higher with a statistically significant different 30-day major amputation rate between the two groups (11.9% group redo vs. 1.3% group de novo; P<0.001). Overall median duration of follow-up was eight months (IQR 6-13). At two-year follow-up there were no differences between the two groups in terms of survival (67.7% group de novo vs. 55.8% group redo, P=0.53), primary patency (34.4% group de novo vs. 26.8% group redo, P=0.25), primary assisted patency (43.6% group de novo vs. 28.8% group redo, P=0.12), freedom from reintervention (64.1% group de novo vs. 68.8% group redo, P=0.98), and amputation-free survival (67.8% group de novo vs. 60% group redo, P=0.12). Secondary patency was significantly higher in group de novo (53.7% vs. 32.3%, P=0.05). During the follow-up, the overall rates of graft infection and aneurysmal degeneration were 3.4%, and 0.8%, respectively. CONCLUSIONS: Nevertheless, poorer early outcomes in terms of limb salvage, Omniflow® II biosynthetic graft offers acceptable ywo-year outcomes in redo surgery in CLTI patients with no available autologous vein material. Further studies with larger population sizes are needed to validate these outcomes.


Assuntos
Amputação Cirúrgica , Implante de Prótese Vascular , Prótese Vascular , Isquemia , Salvamento de Membro , Reoperação , Grau de Desobstrução Vascular , Humanos , Masculino , Feminino , Idoso , Isquemia/cirurgia , Isquemia/fisiopatologia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Estudos Retrospectivos , Itália , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Fatores de Tempo , Resultado do Tratamento , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/fisiopatologia , Oclusão de Enxerto Vascular/cirurgia , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Veias/transplante , Veias/cirurgia , Estado Terminal , Fatores de Risco , Desenho de Prótese
11.
Infection ; 52(3): 1153-1158, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38329687

RESUMO

PURPOSE: We aimed to assess risk factors of candida-related Vascular Graft Infections (VGIs). METHODS: We did a case-control study (1:4) matched by age and year of infection, nested in a cohort of patient with a history of VGIs. Cases were defined by a positive culture for Candida spp. in biological samples and controls were defined by a positive culture for bacterial strains only in biological samples. Risk factors for Candida-related VGIs were investigated using multivariate logistic regression. Mortality were compared using survival analysis. RESULTS: 16 Candida-related VGIs were matched to 64 bacterial-related VGIs. The two groups were comparable regarding medical history and clinical presentation. Candida-related VGIs were associated with bacterial strains in 88% (14/16). Gas/fluid-containing collection on abdominal CT scan and the presence of an aortic endoprosthesis were risk factors for Candida spp.-related VGIs [RRa 10.43 [1.81-60.21] p = 0.009 RRa and 6.46 [1.17-35.73] p = 0.03, respectively]. Candida-related VGIs were associated with a higher mortality when compared to bacterial-related VGIs (p = 0.002). CONCLUSIONS: Candida-related VGIs are severe. Early markers of Candida spp. infection are needed to improve their outcome. The suspicion of aortic endoprosthesis infection may necessitate probabilistic treatment with antifungal agents.


Assuntos
Candidíase , Infecções Relacionadas à Prótese , Humanos , Estudos de Casos e Controles , Masculino , Idoso , Feminino , Fatores de Risco , Pessoa de Meia-Idade , Candidíase/microbiologia , Candidíase/tratamento farmacológico , Candidíase/epidemiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/tratamento farmacológico , Candida/isolamento & purificação , Prótese Vascular/efeitos adversos , Prótese Vascular/microbiologia , Idoso de 80 Anos ou mais
12.
BMC Cardiovasc Disord ; 24(1): 124, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38408908

RESUMO

BACKGROUND: This study aims to compare the clinical effects of two distinct surgical approaches, namely 3D printing-assisted extracorporeal pre-fenestration and Castor integrated branch stent techniques, in treating patients with Stanford type B aortic dissections (TBAD) characterized by inadequate proximal landing zones. METHODS: A retrospective analysis was conducted on 84 patients with type B aortic dissection (TBAD) who underwent thoracic endovascular aortic repair (TEVAR) with left subclavian artery (LSA) reconstruction at our center from January 2022 to July 2023. Based on the different surgical approaches, the patients were divided into two groups: the group assisted by 3D printing for extracorporeal pre-fenestration (n = 44) and the group using the castor integrated branch stent (n = 40). Clinical indicators: including general patient information, operative time, surgical success rate, intraoperative and postoperative complication rates, re-intervention rate, and mortality, as well as postoperative aortic remodeling, were compared between the two groups. The endpoint of this study is the post-TEVAR mortality rate in patients. RESULTS: The surgical success rate and device deployment success rate were 100% in both groups, with no statistically significant difference (P > 0.05). However, the group assisted by 3D printing for extracorporeal pre-fenestration had a significantly longer operative time (184.20 ± 54.857 min) compared to the group using the castor integrated branch stent (152.75 ± 33.068 min), with a statistically significant difference (t = 3.215, p = 0.002, P < 0.05). Moreover, the incidence of postoperative cerebral infarction and beak sign was significantly lower in the group assisted by 3D printing for extracorporeal pre-fenestration compared to the castor-integrated branch stent group, demonstrating statistical significance. There were no significant differences between the two groups in terms of other postoperative complication rates and aortic remodeling (P > 0.05). Notably, computed tomography angiography images revealed the expansion of the vascular true lumen and the reduction of the false lumen at three specified levels of the thoracic aorta. The follow-up duration did not show any statistically significant difference between the two groups (10.59 ± 4.52 vs. 9.08 ± 4.35 months, t = 1.561, p = 0.122 > 0.05). Throughout the follow-up period, neither group experienced new endoleaks, spinal cord injuries, nor limb ischemia. In the castor-integrated branch stent group, one patient developed a new distal dissection, prompting further follow-up. Additionally, there was one case of mortality due to COVID-19 in each group. There were no statistically significant differences between the two groups in terms of re-intervention rate and survival rate (P > 0.05). CONCLUSION: Both 3D printing-assisted extracorporeal pre-fenestration TEVAR and castor-integrated branch stent techniques demonstrate good safety and efficacy in treating Stanford type B aortic dissection with inadequate proximal anchoring. The 3D printing-assisted extracorporeal pre-fenestration TEVAR technique has a lower incidence of postoperative cerebral infarction and beak sign, while the castor-integrated branch stent technique has advantages in operative time.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Fatores de Tempo , Stents/efeitos adversos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Complicações Pós-Operatórias/terapia , Aortografia/métodos , Infarto Cerebral/complicações
13.
J Surg Res ; 296: 516-522, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38330677

RESUMO

INTRODUCTION: Recent data suggests that infrarenal abdominal aortic aneurysm (AAA) endovascular repair (EVAR) with large diameter grafts (LGs) may have a higher risk of endoleak and reintervention. However, this has not been studied extensively for fenestrated endovascular aneurysm repair (fEVAR). We, therefore, sought to evaluate the outcomes of patients undergoing fEVAR with large-diameter endografts. METHODS: Patients from the national Vascular Quality Initiative registry who underwent fEVAR for intact juxtarenal AAA were identified. Patients with genetic causes for aneurysms, those with prior aortic surgery, and those undergoing repair for symptomatic or ruptured aneurysms were excluded. Rates of endoleaks and reintervention at periprocedural and long-term follow-up timepoints (9-22 mo) were analyzed in grafts 32 mm or larger (LG) and were compared to those smaller than 32 mm (small diameter graft). RESULTS: A total of 693 patients (22.8% LG) were identified. Overall, demographic variables were comparable except LG exhibited a more frequent history of coronary artery disease (32.9% versus 25.4%, P = 0.037). There were no significant differences in the rates of endoleak at procedural completion. Overall survival at 5 y was no different. The rate of reintervention at 1 y was also no different (log-rank P = 0.86). CONCLUSIONS: While graft size appears to have an association with outcomes in infrarenal aneurysm repair, the same does not appear to be true for fEVAR. Further studies should evaluate the long-term outcomes associated with LG which could alter the approach to repair of AAA with large neck diameters traditionally treated with standard infrarenal EVAR.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Endoleak/cirurgia , Resultado do Tratamento , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese
14.
J Vasc Surg ; 79(6): 1379-1389, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38280686

RESUMO

OBJECTIVE: Infected native aneurysms (INAs) of the abdominal aorta and iliac arteries are uncommon, but potentially fatal. Endovascular aneurysm repair (EVAR) has recently been introduced as a durable treatment option, with outcomes comparable to those yielded by conventional open repair. However, owing to the rarity of the disease, the strengths and limitations of each treatment remain uncertain. The present study aimed to separately assess post-open repair and post-EVAR outcomes and to clarify factors affecting the short-term and late prognosis after each treatment. METHODS: Using a nationwide clinical registry, we investigated 600 patients treated with open repair and 226 patients treated with EVAR for INAs of the abdominal aorta and/or common iliac artery. The relationships between preoperative or operative factors and postoperative outcomes, including 90-day and 3-year mortality and persistent or recurrent aneurysm-related infection, were examined. RESULTS: Prosthetic grafts were used in >90% of patients treated with open repair, and in situ and extra-anatomic arterial reconstruction was performed in 539 and 57 patients, respectively. Preoperative anemia and imaging findings suggestive of aneurysm-enteric fistula were independently associated with poor outcomes in terms of both 3-year mortality (hazard ratio [HR], 1.62; 95% confidence interval [CI], 1.01-2.62; P = .046, and HR, 2.24; 95% CI, 1.12-4.46; P = .022, respectively) and persistent or recurrent infection (odds ratio [OR], 2.16; 95% CI, 1.04-4.49; P = .039, and OR, 4.96; 95% CI, 1.81-13.55; P = .002, respectively) after open repair, whereas omental wrapping or packing and antibiotic impregnation of the prosthetic graft for in situ reconstruction contributed to improved 3-year survival (HR, 0.60; 95% CI, 0.39-0.92; P = .019, and HR, 0.53; 95% CI, 0.32-0.88; P = .014, respectively). Among patients treated with EVAR, abscess formation adjacent to the aneurysm was significantly associated with the occurrence of persistent or recurrent infection (OR, 2.24; 95% CI, 1.06-4.72; P = .034), whereas an elevated preoperative white blood cell count was predictive of 3-year mortality (HR, 1.77; 95% CI, 1.00-3.13; P = .048). CONCLUSIONS: Profiles of prognostic factors differed between open repair and EVAR in the treatment of INAs of the abdominal aorta and common iliac artery. Open repair may be more suitable than EVAR for patients with concurrent abscess formation.


Assuntos
Aneurisma Infectado , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Sistema de Registros , Humanos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Procedimentos Endovasculares/instrumentação , Masculino , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Feminino , Idoso , Aneurisma Ilíaco/cirurgia , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/microbiologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Implante de Prótese Vascular/instrumentação , Aneurisma Infectado/cirurgia , Aneurisma Infectado/microbiologia , Aneurisma Infectado/mortalidade , Aneurisma Infectado/diagnóstico por imagem , Resultado do Tratamento , Fatores de Risco , Fatores de Tempo , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Prótese Vascular/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/diagnóstico , Recidiva , Medição de Risco
16.
J Vasc Surg ; 79(4): 973-981.e4, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37619915

RESUMO

OBJECTIVE: The aim of this study was to evaluate the outcomes after semi-conversion (open conversion with graft preservation) after failed endovascular aneurysm repair (EVAR). The primary outcomes were 30-day mortality and semi-conversion failure. Secondary outcomes were 30-day major systemic complications, endoleak recurrence, reinterventions, and overall survival. METHODS: The review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The protocol was prospectively registered on PROSPERO (CRD42023421153). All studies reporting the outcomes of semi-conversions for failed EVAR were eligible for inclusion. Quality assessment was performed using the Methodological Index for Non-Randomized Studies (MINORS) tool. A random effects meta-regression of proportions was conducted using the double arcsine-Tukey transformation, given the frequent zero event rate in the primary outcome. Heterogeneity was assessed with the I2 statistic. RESULTS: Eight studies were included in the review after full text screening. A total of 196 patients underwent semi-conversion at a mean time from EVAR of 47.4 months, 68.9% in an elective setting. Mean age at conversion was 78.1 years, and the main indication was isolated endoleak type II (70.1% of cases). Aortic clamping was not necessary in 92.3% of semi-conversions; the aortic sac was opened in 96.1% of cases; in 93.3% of cases, ligation/suture of one or more culprit arteries were performed; and aortic neck banding was executed in 29.2%. At 30 days from surgery, the pooled mortality and the major systemic complications rates were 5.3% (I2 = 24.9%) and 13.4% (I2 = 54.3%), respectively. At follow-up, endoleak recurred after 12.6% semi-conversions (I2 = 83.2%), and the rate of reinterventions was 7% (I2 = 50.1%); the semi-conversion failure rate was 5.5% (I2 = 54.1%), and the overall survival was 84.6% (I2 = 33.3%). CONCLUSIONS: Semi-conversions have acceptable 30-day mortality rates, but the early and mid-term risks of complications, reinterventions, ruptures, and infections are not negligible. This procedure might be an alternative to complete or partial graft explant in patients whom aortic cross-clamping is not ideal.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Correção Endovascular de Aneurisma , Resultado do Tratamento , Aorta Abdominal/cirurgia , Fatores de Risco , Estudos Retrospectivos , Prótese Vascular/efeitos adversos
17.
J Neurosurg ; 140(1): 144-152, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37439478

RESUMO

OBJECTIVE: Histopathological studies of aneurysms after coil embolization showed that thrombus formation during the first month after endovascular treatment (EVT) played an important role in the healing process. The authors hypothesized that dedicated T1-weighted imaging may be used to predict stable aneurysms by visualizing the thrombus status within coil-treated aneurysms. Therefore, this study investigated the relationship between the signal intensity (SI) of the intraaneurysmal sac after coil embolization and aneurysm stability. METHODS: The study population included 82 patients with 86 aneurysms who underwent T1-weighted 3D black-blood fast spin-echo (T1 CUBE) imaging within 1 month after coil embolization between 2019 and 2022. The relative SI of a coil-treated aneurysm (RSIcoiled) was calculated as follows: the mean SI of the intraaneurysmal sac/the mean SI of the genu of the corpus callosum. Aneurysms with enlarged remnants on MR angiography (MRA) within 6 months after EVT were defined as recurrence, while a decrease of intraaneurysmal flow on MRA was defined as improved embolization status. Stable aneurysms were defined as improvement or no change in embolization status 6 months after coil embolization. The volume embolization ratio (VER) was calculated as the ratio of the packed coil volume to the aneurysm volume. Differences between stable and recurrent aneurysms were examined. All aneurysms were divided into high and low RSIcoiled groups based on the cutoff value of RSIcoiled, and differences between the two groups were also evaluated. RESULTS: Recurrence was confirmed for 26 of 86 aneurysms. A univariable analysis showed that small aneurysms, high VER, and high RSIcoiled were associated with aneurysm stability. In the receiver operating characteristic curve analysis, the optimal cutoff value for RSIcoiled to differentiate stable from recurrent aneurysms was 0.54. The cutoff value for RSIcoiled was selected as 0.50 (sensitivity 0.77, specificity 0.70) because it was half the value of the SI of the corpus callosum and close to the optimal cutoff value. In a multivariable analysis, RSIcoiled > 0.50 (OR 8.1, 95% CI 2.5-27) remained a significant factor for aneurysm stability. The high RSIcoiled group showed a higher rate of an improved embolization status (26% vs 6.1%, p = 0.022) and stable aneurysms (85% vs 15%, p = 0.0002). CONCLUSIONS: RSIcoiled was associated with postcoiling aneurysm stability. High RSIcoiled might imply intraaneurysmal thrombus formation associated with the healing process of coil-treated aneurysms.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Trombose , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/etiologia , Prótese Vascular/efeitos adversos , Angiografia por Ressonância Magnética , Embolização Terapêutica/métodos , Resultado do Tratamento , Estudos Retrospectivos
18.
J Neurointerv Surg ; 16(4): 385-391, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-37197932

RESUMO

BACKGROUND: The Pipeline Flex embolization device with Shield technology (PED Shield) is the first flow diverter for brain aneurysm treatment approved in the United States using surface-modified technology. The effect of PED Shield on decreasing perioperative diffusion-weighted imaging positive (DWI+) hits, as a marker for in-human decrease thrombogenicity, is unclear. OBJECTIVE: To determine if the number of periprocedural DWI+ lesions differs between patients with an aneurysm treated with PED Flex and PED Shield. METHODS: This retrospective study compares the outcomes of consecutive patients with an aneurysm treated with PED Flex and PED Shield. The primary outcome of interest was the occurrence of DWI+ lesions. We also assessed potential predictors of DWI+ lesions and compared the outcomes between on-label and off-label treatment indications. RESULTS: 89 patients were included, 48 (54%) treated with PED Flex and 41 (46%) with PED Shield. After matching, the incidence of DWI+ lesions was 61% and 62% for the PED Flex and PED Shield groups, respectively. Results were consistent across each model with no significant differences in DWI+ lesions between treatment groups, and effect sizes ranging from OR=1.08 (95% CI 0.41 to 2.89) after propensity score matching to OR=1.84 (95% CI 0.65 to 5.47) after multivariable regression. Multivariable models demonstrated reduced DWI+ lesions with balloon-assisted therapies and posterior circulation treatment, while a significant linear relationship was encountered with fluoroscopy time. CONCLUSION: There was no significant difference in the incidence of perioperative DWI+ lesions between patients with an aneurysm treated with PED Flex and PED Shield. Larger cohorts are likely needed to demonstrate differences between the devices.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Estudos Retrospectivos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/etiologia , Resultado do Tratamento , Embolização Terapêutica/métodos , Prótese Vascular/efeitos adversos
19.
Thorac Cardiovasc Surg ; 72(2): 142-145, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37257506

RESUMO

BACKGROUND: Endovascular thoracic aortic treatment frequently requires extending the proximal landing zone up into the aortic arch with consecutive covering of the left subclavian artery orifice. Our aim was to report on our outcome of left subclavian artery revascularization using carotid-subclavian bypass via lateral access to the subclavian artery. METHODS: Patients' charts in our aortic center were screened for all those who had undergone carotid-subclavian bypass during endovascular thoracic aortic repair procedures. We analyzed perioperative complications such as cervical plexus nerve or phrenic nerve injury, bleeding, and primary and follow-up graft patency. RESULTS: Between 2001 and 2020, 118 patients underwent carotid-subclavian bypass implantation. Postoperative complications included left-sided stroke in 3% and axillary, phrenic, and recurrent laryngeal nerve palsy in 3, 2, and 3%, respectively. Carotid-subclavian bypass-related death rate was 0%. Bypass patency was 92 ± 7% at 5 years. We documented nine (8%) bypass late occlusions with one left upper extremity ischemia and one late stroke due to an embolized thrombus formed at the bypass anastomosis. All others were asymptomatic. CONCLUSION: Carotid-subclavian bypass surgery is associated with very low risk of death, stroke, or any nerve palsy. Lateral access to the left subclavian artery reduces the risk of phrenic nerve injury.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Estudos Retrospectivos , Prótese Vascular/efeitos adversos , Stents/efeitos adversos
20.
J Vasc Interv Radiol ; 35(1): 25-31, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37776993

RESUMO

PURPOSE: To assess the safety and effectiveness of a rotational mechanical atherothrombectomy device in patients with symptomatic iliac limb occlusion after abdominal endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: A retrospective analysis was conducted on patients who underwent rotational mechanical thrombectomy using the Rotarex S device for symptomatic acute, subacute, or chronic graft limb thrombosis at 5 vascular centers between 2017 and 2021. This study comprised 23 male patients with a mean age of 74.5 years (SD ± 7.2) at the time of the procedure. The clinical presentation of the patients varied, with 1 patient experiencing acute limb ischemia and 11 patients (47.8%) experiencing disabling intermittent claudication. The remaining patients developed chronic limb-threatening ischemia after iliac limb occlusion. Early outcomes included technical success, postprocedural complications, and periprocedural mortality. Follow-up evaluations encompassed primary patency, patient survival, freedom from reintervention, and the need for surgical conversion. RESULTS: Technical success was achieved in all cases, with no occurrences of distal embolization during or after the procedure, and no periprocedural deaths were reported. Endograft relining was performed in 82.6% of patients to establish a new, nonthrombogenic surface within the graft. Over a median follow-up period of 8 months (interquartile range, 3-16 months), 2 patients experienced iliac limb reocclusion. No deaths or other reinterventions occurred during the observational follow-up period. CONCLUSIONS: Rotational mechanical thrombectomy for iliac limb occlusion after EVAR appears to be both safe and effective. This technique may uncover intraluminal defects contributing to graft occlusion and enable their resolution within the same procedure.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Estudos Retrospectivos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/cirurgia , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese , Stents/efeitos adversos , Trombectomia/efeitos adversos , Itália
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...