Carbohydr Polym ; 337: 122137, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38710567

RESUMO

Xylans' unique properties make it attractive for a variety of industries, including paper, food, and biochemical production. While for some applications the preservation of its natural structure is crucial, for others the degradation into monosaccharides is essential. For the complete breakdown, the use of several enzymes is required, due to its structural complexity. In fact, the specificity of enzymatically-catalyzed reactions is guided by the surface, limiting or regulating accessibility and serving structurally encoded input guiding the actions of the enzymes. Here, we investigate enzymes at surfaces rich in xylan using surface plasmon resonance spectroscopy. The influence of diffusion and changes in substrate morphology is studied via enzyme surface kinetics simulations, yielding reaction rates and constants. We propose kinetic models, which can be applied to the degradation of multilayer biopolymer films. The most advanced model was verified by its successful application to the degradation of a thin film of polyhydroxybutyrate treated with a polyhydroxybutyrate-depolymerase. The herein derived models can be employed to quantify the degradation kinetics of various enzymes on biopolymers in heterogeneous environments, often prevalent in industrial processes. The identification of key factors influencing reaction rates such as inhibition will contribute to the quantification of intricate dynamics in complex systems.


Assuntos
Ressonância de Plasmônio de Superfície , Xilanos , Xilanos/química , Xilanos/metabolismo , Ressonância de Plasmônio de Superfície/métodos , Cinética , Propriedades de Superfície
2.
Clin Oral Investig ; 28(6): 305, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722356

RESUMO

OBJECTIVE: To evaluate the ability of the water glass treatment to penetrate zirconia and improve the bond strength of resin cement. MATERIAL AND METHODS: Water glass was applied to zirconia specimens, which were then sintered. The specimens were divided into water-glass-treated and untreated zirconia (control) groups. The surface properties of the water-glass-treated specimens were evaluated using surface roughness and electron probe micro-analyser (EPMA) analysis. A resin cement was used to evaluate the tensile bond strength, with2 and without a silane-containing primer. After 24 h in water storage at 37 °C and thermal cycling, the bond strengths were statistically evaluated with t-test, and the fracture surfaces were observed using SEM. RESULTS: The water glass treatment slightly increased the surface roughness of the zirconia specimens, and the EPMA analysis detected the water glass penetration to be 50 µm below the zirconia surface. The application of primer improved the tensile bond strength in all groups. After 24 h, the water-glass-treated zirconia exhibited a tensile strength of 24.8 ± 5.5 MPa, which was significantly higher than that of the control zirconia (17.6 ± 3.5 MPa) (p < 0.05). After thermal cycling, the water-glass-treated zirconia showed significantly higher tensile strength than the control zirconia. The fracture surface morphology was mainly an adhesive pattern, whereas resin cement residue was occasionally detected on the water-glass-treated zirconia surfaces. CONCLUSION: The water glass treatment resulted in the formation of a stable silica phase on the zirconia surface. This process enabled silane coupling to the zirconia and improved the adhesion of the resin cement.


Assuntos
Colagem Dentária , Vidro , Teste de Materiais , Cimentos de Resina , Silanos , Propriedades de Superfície , Resistência à Tração , Água , Zircônio , Zircônio/química , Cimentos de Resina/química , Silanos/química , Água/química , Colagem Dentária/métodos , Vidro/química , Microscopia Eletrônica de Varredura , Análise do Estresse Dentário
3.
Skin Res Technol ; 30(5): e13740, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38720488

RESUMO

BACKGROUND: The human nail has a three-layered structure. Although it would be useful to quantitatively evaluate the changes in deformability of the nail due to various surface treatments, few studies have been conducted. METHODS: The effects of two types of surface treatment-a chemically acting nail softener and a physically acting nail strengthener-on the deformability of human fingernails were investigated. The Young's modulus of each plate of the nail samples before and after softening treatment was determined by nanoindentation. The Young's modulus of the strengthener was determined by conducting a three-point bending test on a polyethylene sheet coated with the strengthener. RESULTS: Young's modulus decreased in order from the top plate against the softening treatment time, and the structural elasticity for bending deformation (SEB) of the nail sample, which expresses the deformability against bending deformation independent of its external dimensions, decreased to 60% after 6 h of treatment. The Young's modulus of the nail strengthener was 244.5 MPa, which is less than 10% of the SEB of the nail. When the nail strengthener was applied to the nail surface, the SEB decreased to 73%, whereas the flexural rigidity increased to 117%. CONCLUSION: Changes in nail deformability caused by various surface treatments for softening and hardening were quantitatively evaluated successfully.


Assuntos
Módulo de Elasticidade , Unhas , Propriedades de Superfície , Humanos , Módulo de Elasticidade/fisiologia , Unhas/fisiologia , Feminino , Elasticidade/fisiologia , Adulto
4.
Int J Nanomedicine ; 19: 4515-4531, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38803996

RESUMO

Introduction: There is an ongoing need for improved healing response and expedited osseointegration on the Ti implants in acetabular fracture sites. To achieve adequate bonding and mechanical stability between the implant surface and the acetabular fracture, a new coating technology must be developed to promote bone integration and prevent bacterial growth. Methods: A cylindrical Ti substrate mounted on a rotating specimen holder was used to implant Ca2+, P2+, and Sr2+ ions at energies of 100 KeV, 75 KeV and 180 KeV, respectively, using a low-energy accelerator to synthesize strontium-substituted hydroxyapatite at varying conditions. Ag2+ ions of energy 100 KeV were subsequently implanted on the as-formed surface at the near-surface region to provide anti-bacterial properties to the as-formed specimen. Results: The properties of the as-formed ion-implanted specimen were compared with the SrHA-Ag synthesized specimens by cathodic deposition and low-temperature high-speed collision technique. The adhesion strength of the ion-implanted specimen was 43 ± 2.3 MPa, which is well above the ASTM standard for Ca-P coating on Ti. Live/dead cell analysis showed higher osteoblast activity on the ion-implanted specimen than the other two. Ag in the SrHA implanted Ti by ion implantation process showed superior antibacterial activity. Discussion: In the ion implantation technique, nano-topography patterned surfaces are not concealed after implantation, and their efficacy in interacting with the osteoblasts is retained. Although all three studies examined the antibacterial effects of Ag2+ ions and the ability to promote bone tissue formation by MC3T3-E1 cells on SrHA-Ag/Ti surfaces, ion implantation techniques demonstrated superior ability. The synthesized specimen can be used as an effective implant in acetabular fracture sites based on their mechanical and biological properties.


Assuntos
Acetábulo , Antibacterianos , Prata , Estrôncio , Titânio , Titânio/química , Titânio/farmacologia , Prata/química , Prata/farmacologia , Estrôncio/química , Estrôncio/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Acetábulo/lesões , Animais , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Osseointegração/efeitos dos fármacos , Camundongos , Propriedades de Superfície , Fraturas Ósseas/terapia , Durapatita/química , Durapatita/farmacologia , Osteoblastos/efeitos dos fármacos , Hidroxiapatitas/química , Hidroxiapatitas/farmacologia , Próteses e Implantes , Íons/química , Íons/farmacologia , Humanos , Linhagem Celular
5.
Clin Oral Investig ; 28(6): 345, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809289

RESUMO

OBJECTIVES: This study aimed to evaluate the effect of restorations made with a glass-hybrid restorative system (GHRS), a high-viscosity glass ionomer restorative material (HVGIC), a high-viscosity bulk-fill composite resin (HVB), a flowable bulk-fill composite resin (FB), and a nanohybrid composite resin (NH), which are commonly preferred in clinical applications on the fracture resistance of teeth in-vitro. MATERIALS AND METHODS: One hundred intact human premolar teeth were included in the study. The teeth were randomly divided into ten groups (n = 10). No treatment was applied to the teeth in Control group. Class II cavities were prepared on the mesial surfaces of the remaining ninety teeth in other groups. For restoration of the teeth, a GHRS, a HVGIC, a HVB, a FB, and a NH were used. Additionally, in four groups, teeth were restored using NH, GHRS, and HVGIC with open and closed-sandwich techniques. After 24 h, fracture resistance testing was performed. One-way ANOVA and Tukey HDS tests were used for statistical analysis of the data. RESULTS: The fracture resistance values of Control group were statistically significantly higher than those of GHRS, HVGIC, FB, NH, HVGIC-CS, GHRS-OS, and HVGIC-OS groups(p < 0.05). There was no statistically significant difference observed between the fracture resistance values of Control, HVB, and GHRS-CS groups (p > 0.05). CONCLUSION: It can be concluded that the use of HVB and the application of GHRS with a closed-sandwich technique may have a positive effect on the fracture resistance of teeth in the restoration of wide Class II cavities. CLINICAL RELEVANCE: The use of high-viscosity bulk-fill composite resin and the application of glass-hybrid restorative system with the closed-sandwich technique in the restoration of teeth with wide Class II cavities could increase the fracture resistance of the teeth.


Assuntos
Dente Pré-Molar , Resinas Compostas , Restauração Dentária Permanente , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro , Teste de Materiais , Fraturas dos Dentes , Resinas Compostas/química , Humanos , Técnicas In Vitro , Restauração Dentária Permanente/métodos , Cimentos de Ionômeros de Vidro/química , Fraturas dos Dentes/prevenção & controle , Viscosidade , Propriedades de Superfície , Preparo da Cavidade Dentária/métodos , Resinas Acrílicas/química
6.
BMC Oral Health ; 24(1): 618, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807102

RESUMO

PURPOSE: This study aimed to investigate the effects of new and used burs on CAD-CAM PMMA resin color changes following thermocycling. MATERIALS AND METHODS: Twenty disk-shaped specimens (10 × 2 mm) were made using a single brand of CAD-CAM polymethyl methacrylate resin (Polident) for the color test. Group N consisted of half of the specimens that were machined using the new tungsten carbide bur set, and Group U consisted of the specimens that were milled using the used bur set (500 machining time). A color test was performed on the specimens both before and after thermocycling. For the statistical analysis, the Kruskal-Wallis and Dunn Pairwise Comparison tests were employed. RESULTS: The ∆E* value of specimens (2.057) milled with the used bur was higher than those of specimens milled with the new bur (0.340), but this value is within clinically acceptable limits. After thermocycling, specimens milled with the utilized burs had the greatest L* (93.850) and b* (5.000) values. After thermocycling, statistically significant differences were discovered between Group N and Group U as well as between specimens milled with the utilized bur before and after thermocycling. CONCLUSION: Thermocycling process have an effect on the mean ∆E values of specimens milled with the used carbide bur, but these ∆E* values were not statistically significant. CLINICAL SIGNIFICANCE: The color and clinical performance of CAD-CAM restorations may be affected by variations in CAD-CAM milling bur properties, particularly those related to their frequent use.


Assuntos
Cor , Desenho Assistido por Computador , Polimetil Metacrilato , Polimetil Metacrilato/química , Teste de Materiais , Materiais Dentários/química , Propriedades de Superfície , Humanos
7.
BMC Oral Health ; 24(1): 620, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807109

RESUMO

BACKGROUND: The mechanical properties of fully crystallized lithium aluminosilicate ceramics may be influenced by intraoral temperature variations and postmilling surface treatment. The purpose of this study is to explore the interplay among glazing, thermocycling, and the mechanical characteristics (namely, fracture toughness and hardness) of fully crystallized lithium aluminosilicate ceramics. METHODS: Bending bars (n = 40) cut from LisiCAD blocks (GC, Japan) were randomly assigned to glazed or unglazed groups (n = 20) and subjected to the single edge v-notch beam method to create notches. A glazing firing cycle was applied to the glazed group, while the unglazed group was not subjected to glazing. Half of the specimens (n = 10) from both groups underwent thermocycling before fracture toughness testing. The fracture toughness (KIC) was evaluated at 23 ± 1 °C using a universal testing machine configured for three-point bending, and the crack length was measured via light microscopy. Seven specimens per group were selected for the hardness test. Hardness was assessed using a Vickers microhardness tester with a 1 kg load for 20 s, and each specimen underwent five indentations following ISO 14705:2016. The Shapiro-Wilk and Kolmogorov-Smirnov tests were used to evaluate the normality of the data and a two-way ANOVA was utilized for statistical analysis. The significance level was set at (α = 0.05). RESULTS: Regardless of the thermocycling conditions, the glazed specimens exhibited significantly greater fracture toughness than did their unglazed counterparts (P < 0.001). Thermocycling had no significant impact on the fracture toughness of either the glazed or unglazed specimens. Furthermore, statistical analysis revealed no significant effects on hardness with thermocycling in either group, and glazing alone did not substantially affect hardness. CONCLUSIONS: The impact of glazing on the fracture toughness of LiSiCAD restorations is noteworthy, but it has no significant influence on their hardness. Furthermore, within the parameters of this study, thermocycling was found to exert negligible effects on both fracture toughness and hardness.


Assuntos
Silicatos de Alumínio , Cerâmica , Desenho Assistido por Computador , Dureza , Teste de Materiais , Cerâmica/química , Silicatos de Alumínio/química , Análise do Estresse Dentário , Propriedades de Superfície , Cristalização
8.
Proc Natl Acad Sci U S A ; 121(22): e2403013121, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38781207

RESUMO

Biomolecular condensates are cellular compartments that concentrate biomolecules without an encapsulating membrane. In recent years, significant advances have been made in the understanding of condensates through biochemical reconstitution and microscopic detection of these structures. Quantitative visualization and biochemical assays of biomolecular condensates rely on surface passivation to minimize background and artifacts due to condensate adhesion. However, the challenge of undesired interactions between condensates and glass surfaces, which can alter material properties and impair observational accuracy, remains a critical hurdle. Here, we introduce an efficient, broadly applicable, and simple passivation method employing self-assembly of the surfactant Pluronic F127 (PF127). The method greatly reduces nonspecific binding across a range of condensates systems for both phase-separated droplets and biomolecules in dilute phase. Additionally, by integrating PF127 passivation with the Biotin-NeutrAvidin system, we achieve controlled multipoint attachment of condensates to surfaces. This not only preserves condensate properties but also facilitates long-time fluorescence recovery after photobleaching imaging and high-precision single-molecule analyses. Using this method, we have explored the dynamics of polySIM molecules within polySUMO/polySIM condensates at the single-molecule level. Our observations suggest a potential heterogeneity in the distribution of available polySIM-binding sites within the condensates.


Assuntos
Avidina , Condensados Biomoleculares , Biotina , Poloxâmero , Condensados Biomoleculares/química , Condensados Biomoleculares/metabolismo , Poloxâmero/química , Biotina/química , Biotina/metabolismo , Avidina/química , Avidina/metabolismo , Recuperação de Fluorescência Após Fotodegradação/métodos , Propriedades de Superfície , Tensoativos/química , Tensoativos/metabolismo , Imagem Individual de Molécula/métodos
9.
Biomolecules ; 14(5)2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38786012

RESUMO

BACKGROUND: Enamel plays an essential role in protecting the underlying layers of the human tooth; therefore, preserving it is vital. This experimental study aimed to evaluate the potential ability of L. brevis to counteract the action of a demineralizing agent on dental enamel morphology and mineral composition in vitro. METHODS: The sample consisted of 12 healthy human posterior teeth. The coronal portion of each tooth was subdivided into two equal parts longitudinally. The specimens were randomly divided into four groups: artificial saliva, L. brevis suspension, demineralizing agent (DA), and DA plus L. brevis. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) were used to evaluate the surface micromorphology and the mineral content, respectively. The statistical analysis was conducted using a one-way ANOVA, followed by Tukey's post hoc test. RESULTS: SEM analysis did not highlight significant changes in the enamel microstructure of L. brevis-treated specimens compared to the control. DA-induced damage to the enamel structure was drastically reduced when the specimens were contextually exposed to the probiotic. The treatment with DA substantially reduced the weight % of crucial enamel minerals, i.e., Ca and P. Notably, the probiotic was able to reverse the demineralization process, bringing Ca and P weight % back to basal levels, including the Ca/P ratio. CONCLUSIONS: The findings indicate that L. brevis is able to efficiently protect the dental enamel surface from the damage caused by DA and increase the enamel resistance to demineralization. Overall, L. brevis confirms its efficacy in preventing or counteracting the action of carious lesions through a novel mechanism that protects the tooth surface under a chemical challenge that mimics the caries process.


Assuntos
Esmalte Dentário , Probióticos , Desmineralização do Dente , Humanos , Esmalte Dentário/efeitos dos fármacos , Desmineralização do Dente/prevenção & controle , Microscopia Eletrônica de Varredura , Espectrometria por Raios X , Propriedades de Superfície , Técnicas In Vitro
10.
J Appl Oral Sci ; 32: e20230440, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775557

RESUMO

This study aimed to compare the quality of root canal obturation (ratio of area occupied by gutta-percha (G), sealer (S), and presence of voids (V)) in different anatomical irregularities (intercanal communications, lateral irregularities, and accessory canals) located at different thirds of the root canal system of mandibular molar replicas. Sixty-seven 3D printed replicas of an accessed mandibular molar were prepared using ProGlider and ProTaper Gold rotatory systems. Three specimens were randomly selected to be used as controls and did not receive further treatment. The rest were randomly distributed in 4 experimental groups to be obturated using either cold lateral compaction (LC), continuous wave of condensation (CW), and core-carrier obturation (ThermafilPlus (TH) or GuttaCore (GC)) (n=16 per group). AHPlus® sealer was used in all groups. The three controls and a specimen from each experimental group were scanned using micro-computed tomography. The rest of the replicas were sectioned at the sites of anatomical irregularities and examined at 30× magnification. The G, S, and V ratios were calculated dividing the area occupied with each element by the total root canal area and then compared among groups using the Kruskal-Wallis test. Voids were present in all obturation techniques with ratios from 0.01 to 0.15. CW obtained a significantly higher G ratio in the irregularity located in the coronal third (0.882) than LC (0.681), TH (0.773), and GC (0.801) (p<0.05). TH and GC achieved significantly higher G ratios in those located in the apical third (p<0.05). The worst quality of obturation was observed in the loop accessory canal with all obturation techniques. Whitin the limitations of this study, it can be concluded that CW and core-carrier obturation are respectively the most effective techniques for obturating anatomical irregularities located in the coronal and the apical third.


Assuntos
Cavidade Pulpar , Guta-Percha , Teste de Materiais , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular , Microtomografia por Raio-X , Obturação do Canal Radicular/métodos , Materiais Restauradores do Canal Radicular/química , Microtomografia por Raio-X/métodos , Guta-Percha/química , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Valores de Referência , Dente Molar/anatomia & histologia , Resinas Epóxi/química , Impressão Tridimensional , Propriedades de Superfície , Estatísticas não Paramétricas , Distribuição Aleatória
11.
ACS Appl Bio Mater ; 7(5): 3096-3109, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38764432

RESUMO

Wire arc additive manufacturing (WAAM) holds promise for producing medium to large industrial components. Application of WAAM in the manufacturing of biomedical materials has not yet been evaluated. The current study addresses two key research questions: first, the suitability of the WAAMed Ti6Al4V alloy for biomedical applications, and second, the effect of Ti6Al4V's constituents (α and ß phases) on the cell viability. The WAAMed Ti6Al4V alloy was fabricated (as-deposited: AD) using a metal inert gas (MIG)-based wire arc system using an in-house designed shielding chamber filled with argon. Subsequently, samples were subjected to solution treatment (950 °C for 1 h), followed by aging at 480 °C (T1), 530 °C (T2), and 580 °C (T3) for 8 h and subsequent normalization to ambient conditions. Microstructural analysis revealed ∼45.45% of α'-Ti colonies in the as-deposited samples, reducing to 23.26% postaging at 580 °C (T3). The α-lath thickness and interstitial oxygen content in the sample were observed to be proportional to the aging temperature, peaking at 580 °C (T3). Remarkably, during tribocorrosion analysis in simulated body fluid, the 580 °C-aged T3 sample displayed the lowest corrosion rate (7.9 µm/year) and the highest coefficient of friction (CoF) at 0.58, showing the effect of increasing oxygen content in the alloy matrix. Cell studies showed significant growth at 530 and 580 °C by day 7, correlated with higher oxygen content, while other samples had declining cell density. Additionally, optimal metallurgical property ranges were identified to enhance the Ti6Al4V alloy's biocompatibility, providing crucial insights for biomedical implant development.


Assuntos
Ligas , Materiais Biocompatíveis , Sobrevivência Celular , Temperatura Alta , Teste de Materiais , Titânio , Titânio/química , Ligas/química , Sobrevivência Celular/efeitos dos fármacos , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Animais , Tamanho da Partícula , Camundongos , Propriedades de Superfície
12.
Eur Rev Med Pharmacol Sci ; 28(9): 3391-3402, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766802

RESUMO

OBJECTIVE: Although pure titanium (PT) and its alloys exhibit excellent mechanical properties, they lack biological activity as implants. The purpose of this study was to improve the biological activity of titanium implants through surface modification. MATERIALS AND METHODS: Titanium was processed into titanium discs, where the titanium discs served as anodes and stainless steel served as cathodes, and a copper- and cobalt-doped porous coating [pure titanium model (PTM)] was prepared on the surface of titanium via plasma electrolytic oxidation. The surface characteristics of the coating were evaluated using field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and profilometry. The corrosion resistance of PTM was evaluated with an electrochemical workstation. The biocompatibility and bioactivity of coated bone marrow mesenchymal stem cells (BMSCs) were evaluated through in vitro cell experiments. RESULTS: A copper- and cobalt-doped porous coating was successfully prepared on the surface of titanium, and the doping of copper and cobalt did not change the surface topography of the coating. The porous coating increased the surface roughness of titanium and improved its resistance to corrosion. In addition, the porous coating doped with copper and cobalt promoted the adhesion and spreading of BMSCs. CONCLUSIONS: A porous coating doped with copper and cobalt was prepared on the surface of titanium through plasma electrolytic oxidation. The coating not only improved the roughness and corrosion resistance of titanium but also exhibited good biological activity.


Assuntos
Materiais Revestidos Biocompatíveis , Cobalto , Cobre , Células-Tronco Mesenquimais , Propriedades de Superfície , Titânio , Titânio/química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Cobre/química , Porosidade , Cobalto/química , Animais , Corrosão , Teste de Materiais , Células Cultivadas , Próteses e Implantes
13.
Clin Exp Dent Res ; 10(3): e901, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38770577

RESUMO

OBJECTIVES: The study aimed to evaluate the debonding resistance of three different endocrown designs on molar teeth, using three different zirconia surface pretreatments. MATERIAL AND METHOD: Ninety human mandibular first molars were divided into three main groups: endocrowns without ferrule, with 1 mm ferrule, and with 2 mm ferrule. The subgroups were defined by their surface pretreatment method used (n = 15): 50 µm alumina air-particle abrasion, silica coating using 30 µm Cojet™ particles, and Zircos-E® etching. The endocrowns were fabricated using multilayer zirconia ceramic, cemented with self-adhesive resin cement, and subjected to 5000 thermocycles (5-55°C) before debonding. The data obtained were analyzed using a two-way ANOVA. RESULTS: All test specimens survived the thermocyclic aging. The results indicated that both the preparation design and the surface treatment had a significant impact on the resistance to debonding of the endocrowns (p < .001). The 2 mm ferrule followed by the 1 mm ferrule designs exhibited the highest debonding resistance, both were superior to the endocrown without ferrule. Zircos-E® etching and silica coating yielded comparable debonding resistance, which were significantly higher than alumina air-particle abrasion. All endocrowns demonstrated a favorable failure mode. CONCLUSIONS: All designs and surface treatments showed high debonding resistance for a single restoration. However, ferrule designs with Zircos-E® etching or silica coating may represent better clinical options compared to the nonferrule design or alumina airborne-particle abrasion. Nonetheless, further research, including fatigue testing and evaluations with different luting agents is recommended.


Assuntos
Óxido de Alumínio , Dióxido de Silício , Propriedades de Superfície , Zircônio , Óxido de Alumínio/química , Humanos , Dióxido de Silício/química , Zircônio/química , Dente Molar , Teste de Materiais , Abrasão Dental por Ar/métodos , Cimentos de Resina/química , Corrosão Dentária/métodos , Análise do Estresse Dentário , Planejamento de Prótese Dentária
14.
Sheng Wu Gong Cheng Xue Bao ; 40(5): 1448-1468, 2024 May 25.
Artigo em Chinês | MEDLINE | ID: mdl-38783808

RESUMO

Nanoparticles, as a novel material, have a wide range of applications in the food and biomedical fields. Nanoparticles spontaneously adsorb proteins in the biological environment, and tens or even hundreds of proteins can form protein corona on the surface of nanoparticles. The formation of protein corona on the surface of nanoparticles is one of the key factors affecting the stability, biocompatibility, targeting, and drug release properties of nanoparticles. The formation mechanism of protein corona is affected by a variety of factors, including the surface chemical properties, sizes, and shapes of nanoparticles and the types, concentrations, and pH of proteins. Studies have shown that the protein structure is associated with protein distribution on the nanoparticle surface, while the protein conformation affects the binding mode and stability of the protein on the nanoparticle surface. Since the mechanism of the formation of protein corona on the surface of nanoparticles is complex, the roles of multiple factors need to be considered comprehensively. Understanding the mechanisms and influencing factors of the formation of protein corona will help us to understand the process of protein corona formation and control the formation of protein corona for specific needs. In this paper, we summarize the recent studies on the mechanisms and influencing factors of the formation of protein corona on the surface of nanoparticles, with a view to providing a theoretical basis for in-depth research on protein corona.


Assuntos
Nanopartículas , Coroa de Proteína , Propriedades de Superfície , Coroa de Proteína/química , Coroa de Proteína/metabolismo , Nanopartículas/química , Adsorção , Conformação Proteica , Humanos
16.
Int J Prosthodont ; 37(7): 165-173, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38787581

RESUMO

PURPOSE: To investigate the impact of printing layer thickness on the optical properties and surface roughness of various 3D-printed resins manufactured by digital light processing (DLP) and indicated for provisional and definitive restorations. MATERIALS AND METHODS: A total of 240 specimens from four different 3D-printing resins-VarseoSmile Crown Plus (Bego; VS), Crowntec (Saremco Dental; CR), GC Temp PRINT (GC Dental; TG), and NextDent C&B MFH (NextDent; ND)-were divided into four groups (n = 60 per group). Each group was further divided into three subgroups (n = 20) according to printing layer thickness (25, 50, and 100 µm). All specimens were subjected to thermocycling with coffee before measurements were taken with a spectroradiometer to calculate color differences. The Kubelka-Munk (K-M) absorption (K) and scattering coefficients (S), translucency parameters (TP), and surface roughness (Ra) values were calculated for each printing layer thickness and compared with those of the 2M2 shade tab (target). The data were analyzed using Mann-Whitney U test, the variance accounted for (VAF) coefficient by Cauchy-Schwarz, and post hoc comparisons using Tukey test (α ≤ .05). RESULTS: S (79% ≤ VAF ≤ 100%) and K (40.45% ≤ VAF ≤ 100%) spectral distribution depended on the wavelength. A 25-µm layer thickness resulted in no significant differences from the 2M2 shade for S (P > .230) and K (P > .200). VS showed significantly different S (P = .004) and K (P = .003) values from those of the shade tab with 50-µm layering thickness, whereas other materials did not show significant differences from the 2M2 shade for S (P > .280) and K (P > .301). The 100-µm layer thickness specimens had significantly different S and K values compared to the 2M2 shade tab (P < .004). TP values of resins with 100-µm layer thickness were significantly lower than resins in 25- and 50-µm layer thicknesses (P < .001). The Ra values of resins increased significantly with 100-µm layer thickness (P ≤ .001). CONCLUSIONS: All tested materials, except for VS, showed color properties similar to the target shade when 25- and 50-µm printing layer thicknesses were used. The translucency of resins tended toward an inverse relationship with printing layer thickness. The surface roughness of resins increased significantly with 100-µm layer thickness. However, all resins with a printing thickness of 25 µm showed better color properties and surface roughness.


Assuntos
Impressão Tridimensional , Propriedades de Superfície , Teste de Materiais , Técnicas In Vitro , Resinas Compostas/química , Resinas Sintéticas/química
17.
Int J Prosthodont ; 37(7): 175-185, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38787582

RESUMO

PURPOSE: To assess the manufacturing accuracy, intaglio surface adaptation, and survival of resin-based CAD/CAM definitive crowns created via additive manufacturing (AM) or subtractive manufacturing (SM). MATERIALS AND METHODS: A maxillary right first molar crown was digitally designed and manufactured using AM hybrid resin composite (VarseoSmile Crown Plus, Bego [AM-HRC]), AM glass filler-reinforced resin composite (Crowntec, Saremco Dental [AM-RC]), and SM polymer-infiltrated ceramic (Vita Enamic, VITA Zahnfabrik [SM-PICN]). Manufacturing accuracy (trueness and precision) was assessed by computing the root mean square (RMS) error (in µm; n = 15 per material). Intaglio surface adaptation was assessed by calculating the average gap distance (µm). Ten crowns from each group were cemented on fiberglass-reinforced epoxy resin dies and cyclically loaded to simulate 5 years of functional loading. One-way ANOVA, post hoc Bonferroni comparison tests, and Levene's test were used to analyze the data (α = .05). RESULTS: AM-RC had higher overall trueness than AM-HRC and SM-PICN (P ≤ .05), whereas the trueness of AM-RC on the external surface was similar to that of SM-PICN (P = .99) and higher than AM-HRC (P = .001). SM-PICN had lower precision than AM-RC and AM-HRC overall and at internal occlusal surfaces (P ≤ .05). Overall intaglio surface adaptation was similar between all groups (P = .531). However, for the axial intaglio surface, AM-RC and AM-HRC had higher adaptation than SM-PICN (P ≤ .05). All tested crowns survived the cyclic loading simulation of 5 years clinical use. CONCLUSIONS: AM-RC showed high manufacturing accuracy and adaptation. The tested resin-based CAD/CAM materials demonstrated clinically acceptable manufacturing accuracy and simulated medium-term durability, justifying the initiation of clinical investigations to determine their potential implementation in daily clinical practice.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária , Técnicas In Vitro , Resinas Compostas/química , Humanos , Adaptação Marginal Dentária , Propriedades de Superfície , Teste de Materiais , Análise do Estresse Dentário , Cerâmica/química , Dente Molar
18.
Int J Prosthodont ; 37(7): 187-193, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38787583

RESUMO

PURPOSE: To characterize material changes that may occur in virgin cobalt-chromium (Co-Cr) alloy powder when it is blended with alloy powders that have been reused multiple times. MATERIALS AND METHODS: Initially, 20 kg of virgin Co-Cr powder was loaded into a laser-sintering device. The tensile test specimens were fabricated in the first (Group 1), fourth (Group 2), seventh (Group 3), tenth (Group 4), and thirteenth (Group 5) production cycles (N = 15). Prior to fabricating the specimens, powder alloy samples were collected from the powder bed for analysis. The tensile strength, elastic modulus, and percent elongation were calculated with tensile testing. Scanning electron microscopy and energy dispersive x-ray spectroscopy (SEM/EDS) and laser particle size distribution (LPSD) were used to analyze the alloy powder samples. The fracture surface of one tensile test specimen from each group was examined via SEM/EDS. One-way ANOVA followed by Dunnett T3 test was used for statistical analysis (α = .05). RESULTS: No difference was observed between groups in terms of tensile strength. A statistically significant difference was observed between Groups 1 and 2 in terms of percent elongation. Groups 2 and 4 were statistically significantly different in terms of both elastic modulus and percent elongation (P ≤ .05). SEM images of the powder alloy showed noticeable differences with increasing numbers of cycles. SEM images and the EDS analysis of the fractured specimens were in accordance with the strength data. CONCLUSIONS: Reusing Co-Cr alloy powder increased the particle size distribution. However, there was no correlation between increased cycle number and the mechanical properties of the powder.


Assuntos
Ligas de Cromo , Teste de Materiais , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Pós , Resistência à Tração , Ligas de Cromo/química , Módulo de Elasticidade , Espectrometria por Raios X , Técnicas In Vitro , Propriedades de Superfície
19.
Int J Prosthodont ; 37(7): 253-263, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38787590

RESUMO

PURPOSE: This study investigated the impact of common surface pretreatments on the contact angle (CA), surface free energy (SFE), and push-out bond strength (PBS) of custom 3D-printed resin posts. MATERIALS AND METHODS: Post spaces of 60 endodontically treated mandibular premolars were prepared. Custom 3D-printed posts made from permanent crown resin were fabricated for 50 randomly selected post spaces. The specimens were then divided into six groups (n = 10) based on their surface pretreatment methods. These methods included sandblasting (SB), silane (SL), hydrofluoric acid (HF), and hydrogen peroxide (HP). Additionally, two control groups were established: glass fiber control (GFC) and permanent resin control (PRC). CA and SFE were measured for each 3D-printed post group. PBS and failure mode analyses were conducted. The data were analyzed using the two-way ANOVA followed by the Tukey post hoc test (α = .05). RESULTS: The lowest CA values were found in the SB and SL groups. The SB group had the highest SFE compared to all other groups. SL markedly enhanced the PBS of the resin post compared to the PRC at the cervical, middle, and apical levels (P = .001, P = .000, and P = .002, respectively), and the values were comparable to those of the GFC (P = .695, P = .999, and P = .992, respectively). Except in the GFC, SB, and SL groups, mixed failure decreased from the cervical to apical levels, while adhesive failure rates increased. CONCLUSIONS: The application of silane and sandblasting to the surfaces of custom 3D-printed resin posts effectively increased their SFE, thereby enhancing their adhesion.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Impressão Tridimensional , Propriedades de Superfície , Humanos , Técnicas In Vitro , Análise do Estresse Dentário , Dente Pré-Molar , Teste de Materiais , Dente não Vital
20.
Dental Press J Orthod ; 29(2): e2423282, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775601

RESUMO

OBJECTIVE: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. METHODS: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. RESULTS: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. CONCLUSIONS: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


Assuntos
Ligas Dentárias , Implantes Dentários , Resistência à Flexão , Teste de Materiais , Microscopia Eletrônica de Varredura , Procedimentos de Ancoragem Ortodôntica , Aço Inoxidável , Propriedades de Superfície , Titânio , Torque , Titânio/química , Aço Inoxidável/química , Procedimentos de Ancoragem Ortodôntica/instrumentação , Procedimentos de Ancoragem Ortodôntica/métodos , Ligas Dentárias/química , Técnicas In Vitro , Espectrometria por Raios X , Análise do Estresse Dentário , Humanos , Estresse Mecânico , Densidade Óssea