Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Clin Nucl Med ; 48(2): e60-e66, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36512649

RESUMO

PURPOSE OF THE REPORT: Ovarian cancer is usually diagnosed in an advanced stage of disease due to the absence of specific symptoms and a lack of sensitive diagnostic methods. Prostate-specific membrane antigen (PSMA) is expressed on prostate cancer cells but can be found in other tumors such as ovarian cancer.The aim of this pilot study was to evaluate the feasibility of using 68 Ga-PSMA-11 PET/CT in detection of ovarian neoplasm before surgical treatment. PATIENTS AND METHODS: Eight women with mean age of 56.0 ± 16.2 years were included in the study. All patients underwent transvaginal ultrasound followed by CT scan of the chest and abdomen as qualification for surgery. Within a 1-week interval, PET/CT was performed on a Siemens Biograph scanner, 60 minutes after injection of 2 MBq/kg 68 Ga-PSMA-11. RESULTS: In 3 cases (37.5%), the 68 Ga-PSMA-11 PET/CT was positive, whereas histological examination confirmed 2 serous ovarian cancer cases and 1 ovarian borderline tumor. The SUV max in the serous ovarian cancer was 8.7 and 4.1, and in the borderline ovarian tumor, it was 13.8. No correlation was found between antigen CA-125 level and 68 Ga-PSMA expression. Range of tumor SUV max was not correlated with stage of disease. The remaining 62.5% (5/8) were negative in 68 Ga-PSMA-11 PET/CT, and histopathology confirmed benign pelvic tumor. CONCLUSIONS: The initial experience supports the potential to use 68 Ga-PSMA-11 in ovarian cancer to differentiate malignant and benign tumors before surgery.This study was approved by the Ethical Committee of the Medical University of Warsaw (KB/2/A/2018).


Assuntos
Radioisótopos de Gálio , Glutamato Carboxipeptidase II , Neoplasias Ovarianas , Antígeno Prostático Específico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Gálio/análise , Neoplasias Ovarianas/diagnóstico por imagem , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos/análise , Antígeno Prostático Específico/análise , Glutamato Carboxipeptidase II/análise
2.
Molecules ; 27(2)2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-35056858

RESUMO

Background: Glucagon-like peptide 1 receptor (GLP-1R) is preferentially expressed in pancreatic islets, especially in ß-cells, and highly expressed in human insulinomas and gastrinomas. In recent years several GLP-1R-avid radioligands have been developed to image insulin-secreting tumors or to provide a tentative quantitative in vivo biomarker of pancreatic ß-cell mass. Exendin-4, a 39-amino acid peptide with high binding affinity to GLP-1R, has been labeled with Ga-68 for imaging with positron emission tomography (PET). Preparation conditions may influence the quality and in vivo behavior of tracers. Starting from a published synthesis and quality controls (QCs) procedure, we have developed and validated a new rapid and simple UV-Radio-HPLC method to test the chemical and radiochemical purity of [68Ga]Ga-NODAGA-exendin-4, to be used in the clinical routine. Methods: Ga-68 was obtained from a 68Ge/68Ga Generator (GalliaPharma®) and purified using a cationic-exchange cartridge on an automated synthesis module (Scintomics GRP®). NODAGA-exendin-4 contained in the reactor (10 µg) was reconstituted with HEPES and ascorbic acid. The reaction mixture was incubated at 100 °C. The product was purified through HLB cartridge, diluted, and sterilized. To validate the proposed UV-Radio-HPLC method, a stepwise approach was used, as defined in the guidance document released by the International Conference on Harmonization of Technical Requirements of Pharmaceuticals for Human Use (ICH), adopted by the European Medicines Agency (CMP/ICH/381/95 2014). The assessed parameters are specificity, linearity, precision (repeatability), accuracy, and limit of quantification. Therefore, a range of concentrations of Ga-NODAGA-exendin-4, NODAGA-exendin-4 (5, 4, 3.125, 1.25, 1, and 0.75 µg/mL) and [68Ga]Ga-NODAGA-exendin-4 were analyzed. To validate the entire production process, three consecutive batches of [68Ga]Ga-NODAGA-exendin-4 were tested. Results: Excellent linearity was found between 5-0.75 µg/mL for both the analytes (NODAGA-exendin-4 and 68Ga-NODAGA-exendin-4), with a correlation coefficient (R2) for calibration curves equal to 0.999, average coefficients of variation (CV%) < 2% (0.45% and 0.39%) and average per cent deviation value of bias from 100%, of 0.06% and 0.04%, respectively. The calibration curve for the determination of [68Ga]Ga-NODAGA-exendin-4 was linear with a R2 of 0.993 and CV% < 2% (1.97%), in accordance to acceptance criteria. The intra-day and inter-day precision of our method was statistically confirmed using 10 µg of peptide. The mean radiochemical yield was 45 ± 2.4% in all the three validation batches of [68Ga]Ga-NODAGA-exendin-4. The radiochemical purity of [68Ga]Ga-NODAGA-exendin-4 was >95% (97.05%, 95.75% and 96.15%) in all the three batches. Conclusions: The developed UV-Radio-HPLC method to assess the radiochemical and chemical purity of [68Ga]Ga-NODAGA-exendin-4 is rapid, accurate and reproducible like its fully automated production. It allows the routine use of this PET tracer as a diagnostic tool for PET imaging of GLP-1R expression in vivo, ensuring patient safety.


Assuntos
Acetatos/química , Cromatografia Líquida de Alta Pressão/métodos , Exenatida/química , Radioisótopos de Gálio/química , Compostos Heterocíclicos com 1 Anel/química , Compostos Radiofarmacêuticos/análise , Compostos Radiofarmacêuticos/química , Acetatos/análise , Calibragem , Cromatografia em Camada Fina , Exenatida/análise , Radioisótopos de Gálio/análise , Compostos Heterocíclicos com 1 Anel/análise , Humanos , Insulinoma/diagnóstico , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/síntese química , Raios Ultravioleta
3.
Blood ; 139(2): 240-244, 2022 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-34525196

RESUMO

Posttreatment evaluation of gastric mucosa-associated lymphoid tissue (MALT) lymphoma currently relies on esophagogastroduodenoscopy with histological assessment of biopsies. Overexpression of the G protein-coupled C-X-C chemokine receptor type 4 (CXCR4) has been previously observed in MALT lymphoma. The aim of this prospective study was to evaluate positron emission tomography (PET) with the novel CXCR4 tracer [68Ga]Pentixafor as a potential alternative to follow up biopsies for assessment of residual disease (noncomplete remission [CR]) after first-line Helicobacter pylori eradication. Forty-six post-H pylori eradication [68Ga]Pentixafor-PET/magnetic resonance imaging (MRI) examinations of 26 gastric MALT lymphoma patients, and 20 [68Ga]Pentixafor-PET/MRI examinations of 20 control group patients without lymphoma, were analyzed. In the MALT lymphoma group, time-matched gastric biopsies were used as reference standard and showed CR in 6 cases. Pooled examination-based accuracy, sensitivity, specificity, and positive and negative predictive values of [68Ga]Pentixafor-PET for detection of residual gastric MALT lymphoma at follow-up were 97.0%, 95.0%, 100.0%, 100.0%, and 92.9%, respectively. Maximum and mean PET standardized uptake values showed moderate correlation with immunohistochemistry-based CXCR4+ cell counts, with correlation coefficients of r = 0.51 and r = 0.52 (P = .008 and P = .006). In summary, CXCR4 imaging with [68Ga]Pentixafor-PET may represent a promising test for assessment of residual gastric MALT lymphomas after H pylori eradication.


Assuntos
Complexos de Coordenação/análise , Radioisótopos de Gálio/análise , Linfoma de Zona Marginal Tipo Células B/diagnóstico por imagem , Peptídeos Cíclicos/análise , Receptores CXCR4/análise , Neoplasias Gástricas/diagnóstico por imagem , Idoso , Antibacterianos/uso terapêutico , Seguimentos , Infecções por Helicobacter/complicações , Infecções por Helicobacter/tratamento farmacológico , Helicobacter pylori/efeitos dos fármacos , Humanos , Linfoma de Zona Marginal Tipo Células B/microbiologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Neoplasias Gástricas/microbiologia
4.
PLoS One ; 16(2): e0246394, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33529259

RESUMO

INTRODUCTION: Dynamic PET/CT allows visualization of pharmacokinetics over the time, in contrast to static whole body PET/CT. The objective of this study was to assess 68Ga-PSMA-11 uptake in pathological lesions and benign tissue, within 30 minutes after injection in primary prostate cancer (PCa) patients in test-retest setting. MATERIALS AND METHODS: Five patients, with biopsy proven PCa, were scanned dynamically in list mode for 30 minutes on a digital PET/CT-scanner directly after an intravenous bolus injection of 100 MBq 68Ga-PSMA-11. Approximately 45 minutes after injection a static whole body scan was acquired, followed by a one bed position scan of the pelvic region. The scans were repeated approximately four weeks later, without any intervention in between. Semi-quantitative assessment was performed using regions-of-interest in the prostate tumor, bladder, gluteal muscle and iliac artery. Time-activity curves were extracted from the counts in these regions and the intra-patient variability between both scans was assessed. RESULTS: The uptake of the iliac artery and gluteal muscle reached a plateau after 5 and 3 minutes, respectively. The population fell apart in two groups with respect to tumor uptake: in some patients the tumor uptake reached a plateau after 5 minutes, whereas in other patients the uptake kept increasing, which correlated with larger tumor volumes on PET/CT scan. Median intra-patient variation between both scans was 12.2% for artery, 9.7% for tumor, 32.7% for the bladder and 14.1% for the gluteal muscle. CONCLUSION: Dynamic 68Ga-PSMA-11 PET/CT scans, with a time interval of four weeks, are reproducible with a 10% variation in uptake in the primary prostate tumor. An uptake plateau was reached for the iliac artery and gluteal muscle within 5 minutes post-injection. A larger tumor volume seems to be related to continued tumor uptake. This information might be relevant for both response monitoring and PSMA-based radionuclide therapies.


Assuntos
Isótopos de Gálio/análise , Radioisótopos de Gálio/análise , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Isótopos de Gálio/administração & dosagem , Isótopos de Gálio/farmacocinética , Radioisótopos de Gálio/administração & dosagem , Radioisótopos de Gálio/farmacocinética , Humanos , Masculino , Pelve/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Próstata/patologia , Neoplasias da Próstata/patologia , Carga Tumoral
5.
Bull Exp Biol Med ; 170(3): 345-349, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33452982

RESUMO

We studied the biodistribution of 68Ga-NODA-aminoglucose (68Ga-NODA-AG) in normal mice and mice with experimental model of colon adenocarcinoma tumor. It was shown that 68Ga-NODA-aminoglucose was retained in the tumor for 3 h after injection and demonstrated high level of accumulation in the tumor. Rapid clearance of radioactivity from other organs was observed. The results suggest that 68Ga-NODA-aminoglucose is a promising agent for tumor visualization by positron emission tomography.


Assuntos
Adenocarcinoma/metabolismo , Neoplasias do Colo/metabolismo , Radioisótopos de Gálio/análise , Tomografia por Emissão de Pósitrons , Animais , Camundongos
6.
Bull Exp Biol Med ; 169(5): 644-647, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32986215

RESUMO

We analyzed biodistribution of 68Ga-labeled hydroxyethylidenediphosphonic acid (68Ga-HEDP) and diethylenetriaminepentakis(methylenephosphonic acid) (68Ga-DTPMP) in Wistar rats with experimental model of bone callus. It was shown that the content of 68Ga-DTPMP and 68Ga-HEDP in bone callus was ~1.5-fold higher than in intact femur. 68Ga-DTPMP was characterized by higher stability in vivo, higher uptake in the bone tissue, and lower uptake in others visceral organs in comparison with 68Ga-HEDP. Thus, 68Ga-DTPMP had more suitable pharmacokinetic properties than 68Ga-HEDP.


Assuntos
Osso e Ossos/metabolismo , Calo Ósseo/metabolismo , Difosfonatos/farmacocinética , Radioisótopos de Gálio/análise , Animais , Difosfonatos/metabolismo , Modelos Animais de Doenças , Ratos , Ratos Wistar
7.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32201272

RESUMO

OBJECTIVE: To optimize radiolabeling with 99mTc and 67Ga of albumin nanoparticles coated with 4 differents synthetic polymers and to evaluate their stability in vivo and in vitro, as well as their biodistribution in vivo after intravenous administration. MATERIAL AND METHODS: The nanoparticles were prepared using albumin and NOTA-modified albumin by the desolvation method and coated with 4 different polymers; HPMC, GMN2, GPM2 and GTM2. They were purified, lyophilized and characterized. Radiolabelling with 99mTc was perfomed with 74 MBq of 99mTc sodium pertechnetate, previously reduced with and acid solution of tin chloride at different concentrations (0.003, 0.005, 0.007, 0.01, 0.05 and 0.1mg/ml) and at different times (5, 10, 15, 30 and 60minutes) and temperatures (room temperature, 40°C and 60°C). Radiolabelling with 67Ga was perfomed by incubation of the nanoparticles with 37 MBq of 67Gallium chloride (obtained from commercial gallium-67 citrate) at different times (10 and 30minutes) and temperatures (room temperature, 30°C and 60°C), and posterior purification with microconcentrators. The radiochemical purity was evaluated by TLC. Stability studies of radiolabeled nanoparticles in physiological serum and blood plasma were perfomed. Biodistribution studies of nanoparticles coated with GPM2 polymer were carried out in Wistar rats after intravenous administration of the nanoparticles. Control animals were carried out with 99mTc sodium pertechnetate and 67Ga chloride. To do so, the animals were killed and activity in organs was measured in a gamma counter. RESULTS: 99mTc labeling was carried out optimally with a tin concentration of 0.007mg/ ml for the GPM2 nanoparticles and 0.005mg / ml for the rest of the formulations, with a radiolabelling time of 10minutes at room temperature. In the case of 67Ga the label was optimized at 30° C temperature and 30minutes of incubation. In both cases the radiochemical purity obtained was greater than 97%. The nanoparticles showed high stability in vitro after 48hours of labeling (70% nanoparticles labeled with 99mTc and 90% those labeled with 67Ga). Biodistribution studies of nanoparticles 99mTc -GPM2 and 67Ga -NOTA-GPM2 showed a high accumulation of activity in the liver at 2 and 24hours after intravenous administration. CONCLUSION: The labeling procedure with 99mTc and 67Ga of albumin and albumin modified with NOTA nanoparticles allows obtaining nanoparticles with high labeling yields and adequate in vitro stability, allowing their use for in vivo studies.


Assuntos
Radioisótopos de Gálio/farmacocinética , Gálio/farmacocinética , Marcação por Isótopo/métodos , Nanopartículas/administração & dosagem , Poliaminas/química , Compostos Radiofarmacêuticos/farmacocinética , Albumina Sérica Humana/farmacocinética , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tecnécio/farmacocinética , Tiamina/química , Animais , Cromatografia em Camada Fina , Estabilidade de Medicamentos , Feminino , Gálio/administração & dosagem , Gálio/análise , Radioisótopos de Gálio/administração & dosagem , Radioisótopos de Gálio/análise , Compostos Heterocíclicos com 1 Anel , Derivados da Hipromelose , Injeções Intravenosas , Nanopartículas/análise , Polietilenoglicóis , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/análise , Ratos , Ratos Wistar , Albumina Sérica Humana/administração & dosagem , Albumina Sérica Humana/análise , Tecnécio/administração & dosagem , Tecnécio/análise , Temperatura , Compostos de Estanho , Distribuição Tecidual
8.
Molecules ; 25(3)2020 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-31979070

RESUMO

The bioorthogonal reaction between a tetrazine and strained transcyclooctene (TCO) has garnered success in pretargeted imaging. This reaction was first validated in nuclear imaging using an 111In-labeled 1,4,7,10tetraazacyclododecane1,4,7,10tetraacetic acid (DOTA)-linked bispyridyl tetrazine (Tz) ([111In]In-DOTA-PEG11-Tz) and a TCO functionalized CC49 antibody. Given the initial success of this Tz, it has been paired with TCO functionalized small molecules, diabodies, and affibodies for in vivo pretargeted studies. Furthermore, the single photon emission tomography (SPECT) radionuclide, 111In, has been replaced with the ß-emitter, 177Lu and α-emitter, 212Pb, both yielding the opportunity for targeted radiotherapy. Despite use of the 'universal chelator', DOTA, there is yet to be an analogue suitable for positron emission tomography (PET) using a widely available radionuclide. Here, a 68Ga-labeled variant ([68Ga]Ga-DOTA-PEG11-Tz) was developed and evaluated using two different in vivo pretargeting systems (Aln-TCO and TCO-CC49). Small animal imaging and ex vivo biodistribution studies were performed and revealed target specific uptake of [68Ga]Ga-DOTA-PEG11-Tz in the bone (3.7 %ID/g, knee) in mice pretreated with Aln-TCO and tumor specific uptake (5.8 %ID/g) with TCO-CC49 in mice bearing LS174 xenografts. Given the results of this study, [68Ga]Ga-DOTA-PEG11-Tz can serve as an alternative to [111In]In-DOTA-PEG11-Tz.


Assuntos
Radioisótopos de Gálio/análise , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Linhagem Celular Tumoral , Feminino , Humanos , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus
9.
Bioconjug Chem ; 31(2): 396-403, 2020 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-31880916

RESUMO

In this study, we applied a new strategy to identify sentinel lymph node (SLN) metastasis by combining 68Ga-NOTA-Evans Blue (68Ga-NEB) for SLN mapping and 68Ga-NOTA-RM26 for LN metastasis detection in breast cancer patients. A total of 24 female patients with breast cancer diagnosed by core biopsy or suspected by mammography or ultrasonography were recruited and provided informed consent. All patients underwent 68Ga-NEB and 68Ga-NOTA-RM26 PET/CT imaging. Visual analysis of 68Ga-NEB PET/CT images was used to determine SLNs, and then compared with the 68Ga-NOTA-RM26 results and histopathological findings. SLNs were visualized in 24 of 24 patients (100.0%) within 4.0-10.0 (5.6 ± 1.4) min. All patients were pathologically diagnosed with breast cancer, and 12 patients had ipsilateral lymph node metastasis. By combining 68Ga-NEB and 68Ga-NOTA-RM26 images, 7/12 (58.3%) patients showed mild to intense uptake of 68Ga-NOTA-RM26 in SLNs, 1/12 patient (8.3%) had moderate uptake of 68Ga-NOTA-RM26 in the non-SLNs rather than SLN, indicating possible bypass lymphatic drainage, partially accounting for the false negatives in SLN biopsy during surgery. No false positives were found. The SUVmax of 68Ga-NOTA-RM26 activity in metastatic SLNs was significantly higher than that in non-metastatic SLNs (2.2 ± 2.3 vs 0.7 ± 0.1, P = 0.047). This study manifests the value of combination of 68Ga-NEB and 68Ga-NOTA-RM26 dual tracer PET/CT in preoperative evaluation of SLN metastasis in breast cancer patients, especially in those patients with lymphatic obstruction and bypass drainage. In general, positive 68Ga-NOTA-RM26 uptake in either SLN or other lymph nodes can apply lymph node dissection rather than intraoperative SLN biopsy.


Assuntos
Neoplasias da Mama/patologia , Metástase Linfática/diagnóstico por imagem , Linfocintigrafia/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Linfonodo Sentinela/diagnóstico por imagem , Azul Evans/análise , Feminino , Radioisótopos de Gálio/análise , Compostos Heterocíclicos com 1 Anel/análise , Humanos , Pessoa de Meia-Idade , Biópsia de Linfonodo Sentinela
10.
Diabetologia ; 63(4): 825-836, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31873789

RESUMO

AIMS/HYPOTHESIS: Type 1 diabetes is characterised by a progressive decline in beta cell mass. This is also observed following implantation of pancreatic islet allografts, but there is no reliable information regarding the time course of beta cell loss. This is due to the limited availability of non-invasive pancreatic islet imaging techniques. We have previously described that dipeptidyl peptidase 6 (DPP6) is an alpha and beta cell-specific biomarker, and developed a camelid antibody (nanobody '4hD29') against it. We demonstrated the possibility to detect DPP6-expressing cells by single-photon emission computed tomography (SPECT)/ computed tomography (CT), but the correlation between the number of cells grafted and the SPECT signal was not assessed. Here, we investigate whether the 4hD29 nanobody allows us to detect different amounts of human pancreatic islets implanted into immune-deficient mice. In addition, we also describe the adaptation of the probe for use with positron emission tomography (PET). METHODS: DPP6 expression was assessed in human samples using tissue arrays and immunohistochemistry. The effect of the 4hD29 nanobody on cell death and glucose-stimulated insulin secretion was measured in EndoC-ßH1 cells and in human islets using Hoechst/propidium iodide staining and an anti-insulin ELISA, respectively. We performed in vivo SPECT imaging on severe combined immunodeficient (SCID) mice transplanted with different amounts of EndoC-ßH1 cells (2 × 106, 5 × 106 and 10 × 106 cells), human islets (1000 and 3000) or pancreatic exocrine tissue using 99mTc-labelled 4hD29 nanobody. This DPP6 nanobody was also conjugated to N-chlorosuccinimide (NCS)-1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA), radiolabelled with either 67Ga (SPECT) or 68Ga (PET) and used in a proof-of-principle experiment to detect DPP6-expressing cells (Kelly neuroblastoma) grafted in SCID mice. RESULTS: The DPP6 protein is mainly expressed in pancreatic islets. Importantly, the anti-DPP6 nanobody 4hD29 allows non-invasive detection of high amounts of EndoC-ßH1 cells or human islets grafted in immunodeficient mice. This suggests that the probe must be further improved to detect lower numbers of islet cells. The 4hD29 nanobody neither affected beta cell viability nor altered insulin secretion in EndoC-ßH1 cells and human islets. The conversion of 4hD29 nanobody into a PET probe was successful and did not alter its specificity. CONCLUSIONS/INTERPRETATION: These findings suggest that the anti-DPP6 4hD29 nanobody may become a useful tool for the quantification of human islet grafts in mice and, pending future development, islet mass in individuals with diabetes.


Assuntos
Rastreamento de Células/métodos , Dipeptidil Peptidases e Tripeptidil Peptidases/imunologia , Células Secretoras de Insulina/metabolismo , Transplante das Ilhotas Pancreáticas , Ilhotas Pancreáticas/diagnóstico por imagem , Anticorpos de Domínio Único/farmacologia , Animais , Contagem de Células , Células Cultivadas , Dipeptidil Peptidases e Tripeptidil Peptidases/antagonistas & inibidores , Feminino , Radioisótopos de Gálio/análise , Radioisótopos de Gálio/farmacocinética , Xenoenxertos , Humanos , Células Secretoras de Insulina/citologia , Ilhotas Pancreáticas/citologia , Ilhotas Pancreáticas/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Camundongos SCID , Camundongos Transgênicos , Imagem Molecular/métodos , Compostos de Organotecnécio/química , Compostos de Organotecnécio/farmacocinética , Traçadores Radioativos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Anticorpos de Domínio Único/análise , Anticorpos de Domínio Único/química
11.
Pituitary ; 22(5): 445-455, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31236798

RESUMO

PURPOSE: Tumors causing ectopic Cushing's syndrome (ECS) are often not visible with conventional imaging. Gallium-68-DOTATATE, DOTATOC, and DOTANOC positron emission tomography/computed tomography (68Ga-SSTR PET/CT) reportedly exhibits greater sensitivity in identifying an ECS source, however, evidence is limited to mainly case reports and a few small retrospective studies. Previous systematic ECS imaging review has shown 68Ga-SSTR PET/CT sensitivity is similar to CT (81.8%) in histologically-proven cases and is 100% in covert-cases, however, the number of patients was small and no occult cases were reported. METHODS: We performed a systematic literature review of 68Ga-SSTR PET/CT use in ECS patients. We also report 6 consecutive patients with confirmed active and occult ECS who underwent 68Ga-DOTATATE PET/CT and were followed at our institution between 2014 and 2019. RESULTS: We identified 33 articles (23 case-reports, 4 case-series, 5 retrospective studies and 1 prospective study) detailing 68Ga-SSTR PET/CT in 69 ECS patients. Overall 68Ga-SSTR PET/CT sensitivity was 64.0%, while in histologically confirmed cases (67 lesions), sensitivity was 76.1%. There were two false-positives cases, both in the adrenal glands. In covert cases, 68Ga-SSTR PET/CT identified 50% of lesions. There were ten occult cases where all imaging failed to identify an adrenocorticotropic hormone source; source remains unknown. In our case series, 68Ga-DOTATATE PET/CT showed decreased uptake in pancreatic neuroendocrine tumor in one patient and did not help identify an ECS source in 5 patients. CONCLUSION: Both this systematic literature review, the largest to date, and our single- center experience demonstrate a lower than previously reported 68Ga-SSTR PET/CT sensitivity for ECS, especially in occult lesions. We suggest that the data on 68Ga-SSTR PET/CT in ECS is subject to publication bias, and false-negatives are likely underreported; it's diagnostic value for ECS needs further study.


Assuntos
Radioisótopos de Gálio/análise , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Receptores de Somatostatina/metabolismo , Animais , Humanos , Estudos Prospectivos , Estudos Retrospectivos
12.
Mol Pharm ; 16(6): 2776-2784, 2019 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-31013092

RESUMO

Neurotensin receptor 1 (NTSR1) is overexpressed in human pancreatic ductal adenocarcinoma (PDAC). Specific noninvasive positron-emission tomography (PET) imaging probes may improve the diagnostic accuracy and the monitoring of therapy for patients with PDAC. Here, we report the use of the 68Ga-labeled neurotensin (NTS) analogue DOTA-NT-20.3 to image human PDAC in animal models and to discriminate tumors from pancreatitis. In addition to the preclinical study, two tissue microarray slides, constructed by small core biopsies (2-5) from standard paraffin-embedded tumor tissues, were used to confirm the high (78%) positivity rate of NTSR1 expression in human PDAC. PET imaging, biodistribution, blocking, and histology studies were performed in subcutaneous AsPC-1 pancreatic tumor-bearing mice. 68Ga-DOTA-NT-20.3 PET images showed rapid tumor uptake and high contrast between the tumor and background with a fast blood clearance and a moderate accumulation in the kidneys. Ex vivo biodistribution showed low uptake in normal pancreas (0.22% IA/g) and in the remaining organs at 1 h postinjection, kidney retention (5.38 ± 0.54% IA/g), and fast clearance from blood and confirmed high uptake in tumors (5.28 ± 0.93% IA/g), leading to a tumor-to-blood ratio value of 6 at 1 h postinjection. The significant decrease of tumor uptake in a blocking study demonstrated the specificity of 68Ga-DOTA-N-T20.3 to target NTSR1 in vivo. PET imaging was also conducted in an orthotopic xenograft model that allows tumors to grow in their native microenvironment and in an experimental pancreatitis model generated by caerulein injections. As opposed to 2-[18F]fluoro-deoxyglucose, 68Ga-DOTA-NT-20.3 distinguishes PDAC from pancreatitis. Thus, 68Ga-DOTA-NT-20.3 is a promising PET imaging probe for imaging PDAC in humans.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Radioisótopos de Gálio/análise , Tomografia por Emissão de Pósitrons/métodos , Animais , Humanos , Masculino , Camundongos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas
13.
Radiat Prot Dosimetry ; 185(3): 371-375, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31034057

RESUMO

Gold activation foils were used in this work to measure thermal, epithermal and fast neutron fluxes in the 18F, 123I, (201Tl, 67Ga) production units in Syrian cyclotron. The neutron flux distribution around the targets were determined. It shows that, the maze thermalizes the fast neutrons and reduces the flux about four orders of magnitudes. The results can be adopted by medical centers to identify radioactive hot spots and develop radiation protection.


Assuntos
Ciclotrons/instrumentação , Ouro/química , Nêutrons , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Radioisótopos de Flúor/análise , Radioisótopos de Gálio/análise , Humanos , Radioisótopos do Iodo/análise , Espalhamento de Radiação , Radioisótopos de Tálio/análise
14.
Nanomedicine ; 17: 26-35, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30654185

RESUMO

The importance of atherosclerosis is driving research to create improved diagnostic tools based on molecular imaging. Pretargeted imaging is the use of bioorthogonal probes that selectively accumulate upon reaction with a pre-modified biomolecule in vivo. To date, this very promising approach has not been applied to atherosclerosis. Neither has been the use of a single nano-radiomaterial for PET / T1-MR imaging of atherosclerosis. Here, we synthesized bioorthogonal nano-radiomaterials for in vivo pretargeted molecular imaging in a mouse model of atherosclerosis. Based on tetrazine-ligation, these functionalized 68Ga iron oxide nano-radiomaterials provide simultaneous PET and T1-MRI signals and selectively accumulate in atherosclerotic plaques in mice sequentially injected with trans-cyclooctene-modified antibodies against oxidized LDL followed by the hybrid nano-radiomaterial. Our results demonstrate the ability of this approach to unambiguously detect atherosclerosis. Furthermore, we show the first example of how hybrid imaging can be used for pretargeted bioorthogonal molecular imaging with nanomaterials.


Assuntos
Aterosclerose/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Animais , Compostos Férricos/análise , Radioisótopos de Gálio/análise , Imageamento por Ressonância Magnética/métodos , Camundongos Endogâmicos C57BL , Modelos Moleculares , Imagem Molecular/métodos , Nanoestruturas/análise , Tomografia por Emissão de Pósitrons/métodos
15.
Phys Med Biol ; 63(24): 24NT01, 2018 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-30524089

RESUMO

In this work we compare spatially variant radioisotope-specific point spread functions (PSFs) derived from published positron range data with measured data using a high resolution research tomograph (HRRT). Spatially variant PSFs were measured on a HRRT for fluorine-18, carbon-11 and gallium-68 using an array of printed point sources. For gallium-68, this required modification of the original design to handle its longer positron range. Using the fluorine-18 measurements and previously published data from Monte-Carlo simulations of positron range, estimated PSFs for carbon-11 and gallium-68 were calculated and compared with experimental data. A double 3D Gaussian function was fitted to the estimated and measured data and used to model the spatially varying PSFs over the scanner field of view (FOV). Differences between the measured and estimated PSFs were quantified using the full-width-at-half-maximum (FWHM) and full-width-at-tenth-maximum (FWTM) in the tangential, radial and axial directions. While estimated PSFs were generally in agreement with the measured PSFs over the entire FOV better agreement was observed (FWHM and FWTM differences of less than 10%) when using one of the two sets of positron range simulations, especially for gallium-68 and for the FWTM. Spatially variant radioisotope specific PSFs can be accurately estimated from fluorine-18 measurements and published positron range data. We have experimentally validated this approach for carbon-11 and gallium-68, and such an approach may be applicable to other radioisotopes such as oxygen-15 for which measurements are not practical.


Assuntos
Simulação por Computador , Elétrons , Radioisótopos de Flúor/análise , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Carbono/análise , Radioisótopos de Gálio/análise , Humanos , Método de Monte Carlo , Radioisótopos de Oxigênio/análise
16.
Pharm Pat Anal ; 7(5): 193-227, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30066605

RESUMO

Commercial 68Ge/68Ga generators provide a means to produce positron emission tomography agents on site without use of a cyclotron. This development has led to a rapid growth of academic literature and patents ongallium-68 (68Ga). As 68Ga positron emission tomography agents usually involve a targeting moiety attached to a metal chelator, the development lends itself to the investigation of theragnostic applications; the 68Ga-based diagnostic is utilized to determine if the biological target is present and, if so, a therapeutic isotope (e.g., 177Lu, 225Ac) can be complexed with the same scaffold to generate a corresponding radiotherapeutic. This review considers patents issued between 2012 and 2017 that contain a 68Ga-labeled molecule indexed by Chemical Abstract Services (a division of the American Chemical Society).


Assuntos
Radioisótopos de Gálio/análise , Patentes como Assunto , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/análise , Animais , Radioisótopos de Gálio/química , Humanos , Estrutura Molecular , Radioquímica , Compostos Radiofarmacêuticos/química
17.
J Pharm Biomed Anal ; 159: 245-251, 2018 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-29990892

RESUMO

This study explores the possibility of formulation of a cold kit for fast and easy preparation of a PET radiopharmaceutical, 68Ga-NOTA-UBI (29-41) for clinical translation. In this study, Circular dichroism (CD) spectroscopy to study conformation of NOTA-UBI (29-41) and its comparison with conformation of UBI (29-41) was done. Pharmaceutical grade cold kits of NOTA-UBI (29-41) were formulated for radiolabeling with 68Ga and necessary quality control tests were carried out. 68Ga-NOTA-UBI (29-41) could be prepared in >90% radiochemical yield and radiochemical purity using cold kits of NOTA-UBI (29-41). In vitro and in vivo evaluation of 68Ga-NOTA-UBI (29-41) was done to demonstrate specificity of the agent for imaging infection. Kits were utilized for preparation of patient dose of 68Ga-NOTA-UBI (29-41). Simple instant thin layer chromatography (ITLC) method for estimating radiolabeling yield of 68Ga-NOTA-UBI (29-41) at hospital radiopharmacy was demonstrated. Clinical evaluation was done in patients with suspected infection. 148-185 MBq of 68Ga-NOTA-UBI (29-41) was injected intravenously in three patients. 68Ga-NOTA-UBI (29-41) uptake could clearly delineate infection foci from non target normal tissues. This is the first report on formulation of a cold kit of NOTA-UBI (29-41) for preparation of 68Ga labeled NOTA-UBI(29-41) at hospital radiopharmacy for infection imaging. Initial clinical evaluation reveal it to be a prospective agent for imaging infection.


Assuntos
Radioisótopos de Gálio/metabolismo , Compostos Heterocíclicos/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Proteínas Ribossômicas/metabolismo , Infecções Estafilocócicas/diagnóstico por imagem , Infecções Estafilocócicas/metabolismo , Animais , Cromatografia Líquida de Alta Pressão/métodos , Radioisótopos de Gálio/análise , Compostos Heterocíclicos/análise , Compostos Heterocíclicos com 1 Anel , Camundongos , Camundongos Endogâmicos BALB C , Proteínas Ribossômicas/análise , Staphylococcus aureus/isolamento & purificação
19.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28750750

RESUMO

A 54-year-old man with progressive prostate cancer underwent a 68Ga-PSMA PET/CT, which showed lymph node and bone metastases. After 2-cycles of 177Lu-PSMA therapy, the repeated 68Ga-PSMA PET/CT showed decreased radiotracer uptake in lymph node and bones metastases, but there were new lesions which may be compatible with progression or tumour sink-effect. A review of 177Lu-PSMA-therapy images revealed that new lesions in the second PET/CT were the metastatic lesions that progressed after the first PET/CT, and subsequently showed a good response. The patient received additional cycles of 177Lu-PSMA therapy, and the disease regressed further, with a PSA of 0.06ng/ml. Response evaluation of new therapeutic diagnostics (theranostic) agents needs a review of not only diagnostic PET/CT images, but also post-therapy images and laboratory results.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/secundário , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Dipeptídeos/uso terapêutico , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Lutécio/uso terapêutico , Metástase Linfática/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Radioisótopos/uso terapêutico , Compostos Radiofarmacêuticos/uso terapêutico , Adenocarcinoma/sangue , Adenocarcinoma/radioterapia , Neoplasias Ósseas/sangue , Neoplasias Ósseas/radioterapia , Dipeptídeos/análise , Monitoramento de Medicamentos , Ácido Edético/análogos & derivados , Ácido Edético/análise , Isótopos de Gálio , Radioisótopos de Gálio/análise , Compostos Heterocíclicos com 1 Anel/análise , Humanos , Lutécio/análise , Metástase Linfática/radioterapia , Masculino , Pessoa de Meia-Idade , Oligopeptídeos/análise , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/radioterapia , Radioisótopos/análise , Compostos Radiofarmacêuticos/análise , Sensibilidade e Especificidade
20.
Appl Radiat Isot ; 134: 112-116, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29273465

RESUMO

The realization and dissemination of the 68Ga activity measurement unit in Cuba is presented. Firstly, the implementation of the Triple to Double Coincidence Ratio (TDCR) method is described for the calibration of the activity concentration of a 68Ga solution using a Hidex™ commercial liquid scintillation counter and a FORTRAN code developed for the calculation of the 68Ga counting efficiencies in the given measurement system. The relative expanded uncertainty (k = 2) associated with the 68Ga activity concentration obtained with the TDCR method is equal to 2%. With the aim to validate this measurement uncertainty estimate, the method is also applied to an Amersham standard solution of 22Na - a positron emitter with a similar decay mode to the 68Ga disintegration scheme from the point of view of type of emitted particles detected in the measurement system. The observed difference between the measured 22Na activity concentration by the TDCR method and the corresponding reference value traceable to NIST is equal to 0.16%. Outcomes of transferring the 68Ga activity standard, realized with the TDCR method, to the secondary standard radionuclide calibrator Capintec CRC™ 15R and to three radionuclide calibrators used for 68Ga PET applications in a hospital are also shown.


Assuntos
Radioisótopos de Gálio/análise , Serviço Hospitalar de Medicina Nuclear , Calibragem , Cuba , Radioisótopos de Gálio/normas , Padrões de Referência , Reprodutibilidade dos Testes , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...