Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 302
Filtrar
1.
Hum Exp Toxicol ; 38(1): 106-117, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29909643

RESUMO

INTRODUCTION:: This study examined the decorporation potential of lansoprazole (LNP) as radioactivity decorporation agent for radiothallium (201Tl) in internally contaminated BALB/c mice and New Zealand White rabbits using radiometry and gamma scintigraphy. METHODS:: Animals were divided into three groups, that is, control, pretreatment-1 (1X LNP), and pretreatment-2 (2X LNP). Mice received LNP intraperitoneally, while in rabbits LNP was given through oral route 0.5 and 1.5 h before radiothallium administration, respectively. Mice and rabbits used in the experiment were administered 1.48 and 11.1 MBq radiothallium (201TlCl) through intravenous and oral route, respectively. Once started as prophylactic, LNP was continued as therapeutic twice a day till the end of study period. Radiometry and gamma scintigraphy were used to monitor radiothallium retention and uptake patterns in animals. Gamma scintigraphic images of rabbits were taken at different time intervals up to 72 h and were analyzed for comparative uptake pattern of 201TlCl in all the groups. RESULTS:: LNP treatment significantly increased the 201Tl elimination over untreated control and considerably reduced the retention of 201Tl in various tissues and organs. Decrease in radiothallium uptake up to 40% was observed in LNP-treated mice as compared to untreated control. While in rabbits, whole-body radioactivity burden at 72 h was found to be 31.24%, 26%, and 18.54% in untreated control, 9 and 18 mg/kg LNP-treated groups, respectively. CONCLUSION:: LNP exhibited dose-dependent decorporation potential to effectively enhance the elimination of 201Tl in mice and rabbits experimentally contaminated with 201TlCl.


Assuntos
Lansoprazol/farmacologia , Inibidores da Bomba de Prótons/farmacologia , Radioisótopos de Tálio/farmacocinética , Animais , Descontaminação , Masculino , Camundongos Endogâmicos BALB C , Coelhos , Cintilografia , Distribuição Tecidual
2.
Heart Vessels ; 32(9): 1062-1066, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28382386

RESUMO

Myocardial perfusion single-photon emission computed tomography (SPECT) is often performed even in patients with suspected coronary artery disease complicated by anemia. We assessed the effects of hemoglobin level on myocardial washout rate of Thallium-201 (Tl-201) in patients with normal myocardial perfusion assessed by SPECT. The study population consisted of 231 patients with summed stress score of zero on SPECT. The mean myocardial washout rate of Tl-201 in the left ventricle was calculated from the stress and the redistribution Bull's eye map. Hematological test was performed within 2 weeks before gated SPECT. There were 135 male and 96 female patients with a mean age of 72.6 ± 9.0 years. The mean hemoglobin was 12.9 ± 1.9 mg/dl; the median was 13.2 mg/dl and the range was 8.0-16.5 mg/dl. There was a significant inverse correlation between hemoglobin level and myocardial washout rate of Tl-201 (r = -0.45, p < 0.001). Univariate linear regression analysis showed that age, female, body mass index, serum creatinine, hemoglobin, end-diastolic volume, and ejection fraction were associated with myocardial washout rate of Tl-201. Multivariate analysis showed that only hemoglobin was the independent predictor of myocardial washout rate of Tl-201 (ß = -0.35, p < 0.001). Our data suggested that anemia was a major determinant of increased myocardial washout rate of Tl-201 in patients with normal myocardial perfusion on SPECT.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Circulação Coronária/fisiologia , Hemoglobinas/metabolismo , Miocárdio/metabolismo , Radioisótopos de Tálio/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Biomarcadores/metabolismo , Doença da Artéria Coronariana/metabolismo , Feminino , Humanos , Masculino , Estudos Retrospectivos
3.
AJR Am J Roentgenol ; 208(1): 171-179, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27726429

RESUMO

OBJECTIVE: The radiologic differential diagnosis of giant cell tumors (GCTs) is challenging because there is a risk of misdiagnosis of GCTs as malignant lesions such as atypically presenting osteosarcomas (OSs). This study aims to assess the feasibility of 201Tl scintigraphy for the differential diagnosis of GCT and atypical OS. MATERIALS AND METHODS: Thallium-201 scintigraphy scans obtained between January 2006 and October 2015 of patients with histologically proven GCT (23 patients [male-to-female ratio, 15:8]; median age, 33.0 years; age range, 20-61 years) and patients with atypically presenting OS (20 patients [male-to-female ratio, 11:9]; median age, 30.0 years; age range, 12-69 years) were retrospectively reviewed. Morphologic classification of osseous lesions was performed on radiographs and CT scans. The 201Tl scintigraphy-based tumor-to-background contrast (TBC) and washout rate (WR) were calculated on early phase and delayed phase scans. The laboratory parameters lactate dehydrogenase (LDH), C-reactive protein (CRP), and alkaline phosphatase were obtained. Statistical significance was estimated using the Mann-Whitney U test. Cutoff values were calculated for early phase TBC and delayed phase TBC. RESULTS: Twenty-two of 23 GCTs were detected on the initial radiographs, whereas only six of 20 atypical OSs were detected on the initial radiographs. The early phase TBC was increased in GCT (median, 2.59; range, 0.51-12.26) compared with atypical OS (median, 1.68; range, 0.90-6.45) (p = 0.07). The delayed phase TBC was increased in GCT (median, 1.65; range, 0.22-5.26) compared with atypical OS (median, 0.96; range, 0.39-3.76) (p = 0.02). The median WR was not significantly decreased in GCT. The cutoff value for the early phase TBC was 3.90, and the cutoff value for the delayed phase TBC was 1.64; these cutoff values for early and delayed phase TBC yielded a sensitivity of 80.0% and a specificity of 47.8% and 52.2% respectively. Serum LDH (mean: atypical OS vs GCT, 215.5 vs 170.5 U/L, respectively; p = 0.01), alkaline phosphatase (median: 355.0 vs 252.0 U/L; p = 0.03), and CRP (median: 0.21 vs 0.09 mg/dL; p = 0.04) values were significantly increased in atypical OS compared with GCT. CONCLUSION: The intense 201Tl uptake of GCT in combination with laboratory OS biomarkers facilitate the differential diagnosis of GCT and atypically presenting OS.


Assuntos
Neoplasias Ósseas/metabolismo , Tumores de Células Gigantes/metabolismo , Osteossarcoma/metabolismo , Osteossarcoma/patologia , Radioisótopos de Tálio/farmacocinética , Adulto , Neoplasias Ósseas/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Tumores de Células Gigantes/diagnóstico por imagem , Tumores de Células Gigantes/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteossarcoma/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
5.
Mol Imaging ; 14: 373-84, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26162232

RESUMO

The objective of this work was to evaluate the sympathetic nervous system and structure remodeling during the progression of heart failure in a rodent model using dynamic cardiac single-photon emission computed tomography (SPECT). The spontaneously hypertensive rat (SHR) model was used to study changes in the nervous system innervation and perfusion in the left ventricular (LV) myocardium with the progression of left ventricular hypertrophy (LVH) to heart failure. Longitudinal dynamic SPECT studies were performed with seven SHR and seven Wistar-Kyoto (WKY) rats over 1.5 years using a dual-head SPECT scanner with pinhole collimators. Time-activity curves (TACs) of the 123I-MIBG and 201Tl distribution in the LV blood pool and myocardium were extracted from dynamic SPECT data and fitted to compartment models to determine the influx rate, washout rate, and distribution volume (DV) of 123I-MIBG and 201Tl in the LV myocardium. The standardized uptake values (SUVs) of 123I-MIBG and 201Tl in the LV myocardium were also calculated from the static reconstructed images. The influx and washout rates of 123I-MIBG did not show a significant difference between SHRs and WKY rats. The DVs of 123I-MIBG were greater in the SHRs than in the WKY rats (p = .0028). Specifically, the DV of 123I-MIBG became greater in the SHRs by 6 months of age (p = .0017) and was still significant at the age of 22 months. The SUV of 123I-MIBG in SHRs exhibited abnormal values compared to WKY rats from the age of 18 months. There was no difference in the influx rate and the washout rate of 201Tl between the SHRs and WKY rats. The SHRs exhibited greater DV of 201Tl than WKY rats after the age of 18 months (p = .034). The SUV of 201Tl in SHRs did not show any significant difference from WKY at all ages. The higher DV of 123I-MIBG in the LV myocardium reveals abnormal nervous system activity of the SHRs at an age of 6 months, whereas a greater DV of 201Tl in the LV myocardium can only be detected at an age of 18 months. The results show that the abnormal nervous system activity appears earlier than perfusion. Furthermore, the comparison between the DV and the SUV indicates that dynamic SPECT with 123I-MIBG and 201Tl with the kinetic parameter DV is capable of detecting abnormalities of the LV at an early age.


Assuntos
Coração/diagnóstico por imagem , Perfusão , Sistema Nervoso Simpático/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , 3-Iodobenzilguanidina/farmacocinética , Animais , Peso Corporal , Ventrículos do Coração/diagnóstico por imagem , Radioisótopos do Iodo , Miocárdio/metabolismo , Tamanho do Órgão , Ratos Endogâmicos SHR , Radioisótopos de Tálio/farmacocinética
6.
Phys Med Biol ; 60(13): 5083-101, 2015 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26083239

RESUMO

Dual-isotope simultaneous-acquisition (DISA) rest-stress myocardial perfusion SPECT (MPS) protocols offer a number of advantages over separate acquisition. However, crosstalk contamination due to scatter in the patient and interactions in the collimator degrade image quality. Compensation can reduce the effects of crosstalk, but does not entirely eliminate image degradations. Optimizing acquisition parameters could further reduce the impact of crosstalk. In this paper we investigate the optimization of the rest Tl-201 energy window width and relative injected activities using the ideal observer (IO), a realistic digital phantom population and Monte Carlo (MC) simulated Tc-99m and Tl-201 projections as a means to improve image quality. We compared performance on a perfusion defect detection task for Tl-201 acquisition energy window widths varying from 4 to 40 keV centered at 72 keV for a camera with a 9% energy resolution. We also investigated 7 different relative injected activities, defined as the ratio of Tc-99m and Tl-201 activities, while keeping the total effective dose constant at 13.5 mSv. For each energy window and relative injected activity, we computed the IO test statistics using a Markov chain Monte Carlo (MCMC) method for an ensemble of 1,620 triplets of fixed and reversible defect-present, and defect-absent noisy images modeling realistic background variations. The volume under the 3-class receiver operating characteristic (ROC) surface (VUS) was estimated and served as the figure of merit. For simultaneous acquisition, the IO suggested that relative Tc-to-Tl injected activity ratios of 2.6-5 and acquisition energy window widths of 16-22% were optimal. For separate acquisition, we observed a broad range of optimal relative injected activities from 2.6 to 12.1 and acquisition energy window of widths 16-22%. A negative correlation between Tl-201 injected activity and the width of the Tl-201 energy window was observed in these ranges. The results also suggested that DISA methods could potentially provide image quality as good as that obtained with separate acquisition protocols. We compared observer performance for the optimized protocols and the current clinical protocol using separate acquisition. The current clinical protocols provided better performance at a cost of injecting the patient with approximately double the injected activity of Tc-99m and Tl-201, resulting in substantially increased radiation dose.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Modelos Cardiovasculares , Imagem de Perfusão do Miocárdio/normas , Compostos de Organotecnécio/farmacocinética , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão de Fóton Único/normas , Simulação por Computador , Humanos , Método de Monte Carlo , Imagem de Perfusão do Miocárdio/métodos , Curva ROC , Compostos Radiofarmacêuticos/farmacocinética , Radioisótopos de Tálio/farmacocinética , Distribuição Tecidual
8.
Neurol Med Chir (Tokyo) ; 54(8): 686-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24418788

RESUMO

Microcystic meningiomas are rare but benign brain tumors. Previous reports have shown that Thallium-201 single-photon emission computed tomography ((201)Tl SPECT) demonstrated a higher late-phase accumulation of (201)Tl in malignant or recurrent meningiomas than in nonaggressive meningiomas. No study has reported (201)Tl SPECT findings in microcystic meningiomas. We here describe a case of a microcystic meningioma with a high (201)Tl SPECT retention rate in a 62-year-old woman who complained of headache. Computed tomography revealed an intracranial tumor in the right frontal lobe. Moreover, (201)Tl SPECT revealed a high uptake of (201)Tl in the tumor, which was particularly prominent in the delayed phase. The uptake index on an early image was 1.46 and that on a delayed image was 1.35. Therefore, the retention index was 0.92. After 2 years of tumor growth, we performed successful radical resection, and histological examination revealed the presence of a microcystic meningioma. Therefore, we concluded that (201)Tl SPECT may be useful for the preoperative diagnosis of microcystic meningiomas and that late-phase accumulation of (201)Tl is not a specific finding of malignant brain tumors. Therefore, we need to be careful in the evaluation and judgment of high retention in a delayed image of (201)Tl SPECT.


Assuntos
Neoplasias Meníngeas/diagnóstico por imagem , Neoplasias Meníngeas/cirurgia , Meningioma/diagnóstico por imagem , Meningioma/cirurgia , Radioisótopos de Tálio/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Meníngeas/patologia , Meningioma/patologia , Pessoa de Meia-Idade , Sensibilidade e Especificidade
9.
Cancer Imaging ; 12: 31-40, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22375306

RESUMO

We have previously reported on a method for reconstructing quantitative data from 99mTc single photon emission computed tomography (SPECT) images based on corrections derived from X-ray computed tomography, producing accurate results in both experimental and clinical studies. This has been extended for use with the radionuclide ²°¹Tl. Accuracy was evaluated with experimental phantom studies, including corrections for partial volume effects where necessary. The quantitative technique was used to derive standardized uptake values (SUVs) for ²°¹Tl evaluation of brain tumours. A preliminary study was performed on 26 patients using ²°¹Tl SPECT scans to assess residual tumor after surgery and then to monitor response to treatment, with a follow-up time of 18 months. Measures of SUVmax were made following quantitative processing of the data and using a threshold grown volume of interest around the tumour. Phantom studies resulted in the calculation of concentration values consistently within 4% of true values. No continuous relation was found between SUVmax (post-resection) and patient survival. Choosing an SUVmax cut-off of 1.5 demonstrated a difference in survival between the 2 groups of patients after surgery. Patients with an SUVmax<1.5 had a 70% survival rate over the first 10 months, compared with a 47% survival rate for those with SUVmax>1.5. This difference did not achieve significance, most likely due to the small study numbers. By 18 months follow-up this difference had reduced, with corresponding survival rates of 40% and 27%, respectively. Although this study involves only a small cohort, it has succeeded in demonstrating the possibility of an SUV measure for SPECT to help monitor response to treatment of brain tumours and predict survival.


Assuntos
Algoritmos , Neoplasias Encefálicas/diagnóstico por imagem , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/farmacocinética , Radioisótopos de Tálio/farmacocinética , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Astrocitoma/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Resultado do Tratamento
10.
Circ Cardiovasc Imaging ; 4(6): 685-92, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21917783

RESUMO

BACKGROUND: There is a well-recognized need for a new generation of single photon emission computed tomography (SPECT) perfusion tracers with improved myocardial extraction over a wide flow range. Radiotracers that target complex I of the mitochondrial electron transport chain have been proposed as a new class of myocardial perfusion imaging agents. 7-(Z)-[(125)I]iodorotenone ((125)I-ZIROT) has demonstrated superior myocardial extraction and retention characteristics in rats and in isolated perfused rabbit hearts. We sought to fully characterize the biodistribution and myocardial extraction versus flow relationship of (123)I-ZIROT in an intact large-animal model. METHODS AND RESULTS: The (123)I-ZIROT was administered during adenosine A(2A) agonist-induced hyperemia in 5 anesthetized dogs with critical left anterior descending (LAD) stenoses. When left circumflex (LCx) flow was maximal, (123)I-ZIROT and microspheres were coinjected and the dogs were euthanized 5 minutes later. (123)I-ZIROT biodistribution was evaluated in 2 additional dogs by in vivo planar imaging. At (123)I-ZIROT injection, transmural LAD flow was unchanged from baseline (mean±SEM, 0.90±0.22 versus 0.87±0.11 mL/[min · g]; P=0.92), whereas LCx zone flow increased significantly (mean±SEM, 3.25±0.51 versus 1.00±0.17 mL/[min · g]; P<0.05). Myocardial (123)I-ZIROT extraction tracked regional myocardial flow better than either thallium-201 or (99m)Tc-sestamibi from previous studies using a similar model. Furthermore, the (123)I-ZIROT LAD/LCx activity ratios by ex vivo imaging or well counting (mean±SEM, 0.42±0.08 and 0.45±0.1, respectively) only slightly underestimated the LAD/LCx microsphere flow ratio (0.32±0.09). CONCLUSIONS: The ability of (123)I-ZIROT to more linearly track blood flow over a wide range makes it a promising new SPECT myocardial perfusion imaging agent with potential for improved coronary artery disease detection and better quantitative estimation of the severity of flow impairment.


Assuntos
Estenose Coronária/diagnóstico por imagem , Hemodinâmica/fisiologia , Radioisótopos do Iodo , Rotenona/análogos & derivados , Radioisótopos de Tálio/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Agonistas do Receptor A2 de Adenosina , Animais , Circulação Coronária/efeitos dos fármacos , Estenose Coronária/fisiopatologia , Estado Terminal , Modelos Animais de Doenças , Cães , Ecocardiografia sob Estresse , Aumento da Imagem/métodos , Masculino , Distribuição Aleatória , Rotenona/farmacocinética , Sensibilidade e Especificidade
11.
Rev Esp Med Nucl ; 29(6): 293-8, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20570016

RESUMO

OBJECTIVE: Extracardiac activity (ECA) may affect interpretation of gated SPECT myocardial perfusion studies (MPSs). To solve this problem, available softwares include myocardial edge delimitation. PURPOSE: To evaluate the influence of ECA in automatic myocardial edge detection under normal conditions and with abnormal perfusion and also evaluate the reproducibility of semi-automatic processing. METHODS: A total of 100 MPSs, 50 with ECA, were analyzed. Each subgroup included 25 cases with perfusion abnormalities. The cases were processed automatically and by 4 independent operators with different levels of experience. Commercial QGS and QPS softwares were used with tools to mask and relocate the left ventricle area. Functional parameters (final diastolic and systolic volumes and ejection fraction) and perfusion parameters such as the reversibility perfusion score and rest perfusion defect extension were analyzed. The data were compared with Pearson's correlation and Student's test. RESULTS: Interobserver correlation significantly worsened with the presence of ECA and was moderately affected by perfusion abnormalities. More experienced observers presented better correlation. Reproducibility was greater for the functional perfusion parameters, independently of the observer's experience. CONCLUSIONS: ECA significantly affects automatic edging delimitation, affecting the MPS values. Interobserver reproducibility with manual processing was more altered regarding functional parameters than in the perfusion scores. Perfusion abnormalities did not interfere with software reproducibility, and when present, better correlation was found. If ECA is not present, manual intervention should be avoided.


Assuntos
Artefatos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Isquemia Miocárdica/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Variações Dependentes do Observador , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Idoso , Automação , Feminino , Humanos , Intestinos/diagnóstico por imagem , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/patologia , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Software , Volume Sistólico , Tecnécio Tc 99m Sestamibi/farmacocinética , Radioisótopos de Tálio/farmacocinética , Distribuição Tecidual
12.
Rev Esp Med Nucl ; 28(4): 193-9, 2009.
Artigo em Espanhol | MEDLINE | ID: mdl-19922832

RESUMO

INTRODUCTION: This study has aimed to establish quantitative normality parameters in the thallium-201 GATED SPECT and to assess the changes related to age, gender, risk factors and stress testing. METHODS: A total of 427 patients with low pre-test likelihood of coronary artery disease were selected (45.5% men). The examinations were performed, by obtaining 32 25-second images on a 180% arc. The isotope used was thallium-201 and the SU SEGAMI software was using for the examination procedure. RESULTS: Myocardial tracer uptake in each one of the vascular territories was: left descending artery 77%+/-4; circumflex artery 76%+/-5 and right coronary artery 70%+/-4 (P=.000). Uptake in the right coronary artery territory was lower in men (68.7% vs 70.5% in women, P=.000) and in the left descending artery territory in the obese. There were no gender-related differences in the post-stress ejection fraction for both genders (65.7% in men vs 66.8% in women). However, ventricular volumes were higher in men (end-diastolic volume 80ml+/-27 vs 61ml+/-22; P=0.000 and end-systolic volume 27.2ml+/-25 vs 19ml+/-8; P=0.000). There is an inverse relationship between age and end-diastolic volume. Smokers have higher end-diastolic volumes than non-smokers. CONCLUSIONS: Quantification of T1201 uptake in patients having low pre-test probability of coronary artery disease and normal thallium GATED-SPECT in the RCA territory is lower in men. The ventricular function study shows that there are no differences in post-stress EF based on gender but that the end-diastolic and end-systolic volumes are higher in men.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Compostos Radiofarmacêuticos , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Fatores Etários , Doença das Coronárias/complicações , Doença das Coronárias/epidemiologia , Doença das Coronárias/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Teste de Esforço , Feminino , Humanos , Hipercolesterolemia/complicações , Hipertensão/complicações , Masculino , Obesidade/complicações , Compostos Radiofarmacêuticos/farmacocinética , Risco , Fatores de Risco , Fatores Sexuais , Fumar , Volume Sistólico , Radioisótopos de Tálio/farmacocinética , Distribuição Tecidual
13.
JACC Cardiovasc Imaging ; 2(10): 1198-208, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19833310

RESUMO

OBJECTIVES: The purpose of this study was to compare a selective A(2A) adenosine receptor agonist (regadenoson) with adenosine in clinically relevant canine models with regard to effects on hemodynamics and thallium-201 ((201)Tl) and technetium-99m ((99m)Tc)-sestaMIBI biodistribution and kinetics. BACKGROUND: The clinical application of vasodilator stress for perfusion imaging requires consideration of the effects of these vasodilating agents on systemic hemodynamics, coronary flow, and radiotracer uptake and clearance kinetics. METHODS: Sequential imaging and arterial blood sampling was performed on control, anesthetized closed-chest canines (n = 7) to evaluate radiotracer biodistribution and kinetics after either a bolus administration of regadenoson (2.5 microg/kg) or 4.5-min infusion of adenosine (280 microg/kg). The effects of regadenoson on coronary flow and myocardial radiotracer uptake were then evaluated in an open-chest canine model of a critical stenosis (n = 7). Results from ex vivo single-photon emission computed tomography were compared with tissue well-counting. RESULTS: The use of regadenoson compared favorably with adenosine in regard to the duration and magnitude of the hemodynamic effects and the effect on (201)Tl and (99m)Tc-sestaMIBI biodistribution and kinetics. The arterial blood clearance half-time was significantly faster for (99m)Tc-sestaMIBI (regadenoson: 1.4 +/- 0.03 min; adenosine: 1.5 +/- 0.08 min) than for (201)Tl (regadenoson: 2.5 +/- 0.16 min, p < 0.01; adenosine: 2.7 +/- 0.04 min, p < 0.01) for both vasodilator stressors. The relative microsphere flow deficit (0.34 +/- 0.02%) during regadenoson stress was significantly greater than the relative perfusion defect with (99m)Tc-sestaMIBI (0.69 +/- 0.03%, p < 0.001) or (201)Tl (0.53 +/- 0.02%, p < 0.001), although (201)Tl tracked the flow deficit within the ischemic region better than (99m)Tc-sestaMIBI. The perfusion defect score was larger with (201)Tl (22 +/- 2.8% left ventricular) than with (99m)Tc-sestaMIBI (17 +/- 1.7% left ventricular, p < 0.05) on ex vivo single-photon emission computed tomography images. CONCLUSIONS: The bolus administration of regadenoson produced a hyperemic response comparable to a standard infusion of adenosine. The biodistribution and clearance of both (201)Tl and (99m)Tc-sestaMIBI during regadenoson were similar to adenosine vasodilation. Ex vivo perfusion images under the most ideal conditions permitted detection of a critical stenosis, although (201)Tl offered significant advantages over (99m)Tc-sestaMIBI for perfusion imaging during regadenoson vasodilator stress.


Assuntos
Agonistas do Receptor A2 de Adenosina , Adenosina/farmacologia , Circulação Coronária/efeitos dos fármacos , Estenose Coronária/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Purinas/farmacologia , Pirazóis/farmacologia , Compostos Radiofarmacêuticos/farmacocinética , Tecnécio Tc 99m Sestamibi/farmacocinética , Radioisótopos de Tálio/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único , Vasodilatadores/farmacologia , Doença Aguda , Adenosina/administração & dosagem , Animais , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Doença Crônica , Estenose Coronária/metabolismo , Estenose Coronária/fisiopatologia , Modelos Animais de Doenças , Cães , Hiperemia/diagnóstico por imagem , Hiperemia/fisiopatologia , Infusões Intravenosas , Injeções Intravenosas , Taxa de Depuração Metabólica , Miocárdio/metabolismo , Miocárdio/patologia , Valor Preditivo dos Testes , Purinas/administração & dosagem , Pirazóis/administração & dosagem , Compostos Radiofarmacêuticos/sangue , Receptor A2A de Adenosina/metabolismo , Tecnécio Tc 99m Sestamibi/sangue , Radioisótopos de Tálio/sangue , Distribuição Tecidual , Vasodilatadores/administração & dosagem
16.
Am J Physiol Heart Circ Physiol ; 295(6): H2522-9, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18996988

RESUMO

Viable, chronically dysfunctional myocardium with reduced resting flow (or hibernating myocardium) is an important prognostic factor in ischemic heart disease. Although thallium-201 imaging is frequently used to assess myocardial viability in patients with ischemic cardiomyopathy, there are limited data regarding its deposition in hibernating myocardium, and this data suggest that thallium retention may be supernormal compared with control myocardium. Accordingly, pigs (n=7) were chronically instrumented with a 1.5 mm Delrin stenosis on the proximal left anterior descending coronary artery (LAD) to produce hibernating myocardium. Four months later, severe anteroapical hypokinesis was documented with contrast ventriculography (wall motion score, 0.7+/-0.8; normal=3), and microsphere measurements confirmed reduced resting flow (LAD subendocardium, 0.78+/-0.34 vs. 0.96+/-0.24 ml.min(-1).g(-1) in remote; P<0.001). Absolute deposition of thallium-201 and insulin-stimulated [18F]-2 fluoro-2-deoxyglucose (FDG) were assessed over 1 h and compared with resting flow (n=704 samples). Thallium-201 deposition was only weakly correlated with perfusion (r2=0.20; P<0.001) and was more homogeneously distributed (relative dispersion, 0.12+/-0.03 vs. 0.29+/-0.10 for microsphere flow; P<0.01). Thus after 1 h relative thallium-201 (subendocardium LAD/remote, 0.96+/-0.16) overestimated relative perfusion (0.78+/-0.32; P<0.0001) and underestimated the relative reduction in flow. Viability was confirmed by both histology and preserved FDG uptake. We conclude that under resting conditions, thallium-201 redistribution in hibernating myocardium is nearly complete within 1 h, with similar deposition to remote myocardium despite regional differences in flow. These data suggest that in this time frame thallium-201 deposition may not discriminate hibernating myocardium from dysfunction myocardium with normal resting flow. Since hibernating myocardium has been associated with a worse prognosis, this limitation could have significant clinical implications.


Assuntos
Circulação Coronária , Estenose Coronária/complicações , Imagem de Perfusão do Miocárdio , Miocárdio Atordoado/metabolismo , Miocárdio Atordoado/fisiopatologia , Miocárdio/metabolismo , Radioisótopos de Tálio/farmacocinética , Animais , Estenose Coronária/metabolismo , Estenose Coronária/patologia , Estenose Coronária/fisiopatologia , Modelos Animais de Doenças , Fluordesoxiglucose F18/administração & dosagem , Fluordesoxiglucose F18/farmacocinética , Infusões Parenterais , Injeções Intravenosas , Insulina/administração & dosagem , Miocárdio Atordoado/etiologia , Miocárdio Atordoado/patologia , Miocárdio/patologia , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Suínos , Radioisótopos de Tálio/administração & dosagem , Sobrevivência de Tecidos
17.
Am J Ther ; 15(5): 431-4, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18806518

RESUMO

Approximately 6 million cardiac stress tests are performed annually in the United States, of which 2.4 million are pharmacologic stress tests using agents such as adenosine. Adenosine induces differential coronary hyperemia in normal coronary arteries versus coronary arteries with atherosclerosis, allowing single photon emission computed tomography (SPECT) imaging to identify reduced coronary flow in segments subtended by diseased coronary arteries. The potential attenuation of pharmacologic effects of adenosine in the presence of caffeine is why patients are routinely instructed to abstain from caffeine for 12 to 24 hours prior to administration of an adenosine stress test. Failure to abstain from caffeine results in cancellation or delaying of cardiac stress testing, resulting in procedural delays and its impact on patient throughput. Recent studies have evaluated such interaction and suggested a lack of clinically significant effect of caffeine on adenosine-induced hyperemia during myocardial SPECT imaging. This article reviews the clinical pharmacology of caffeine, adenosine, and dipyridamole and effect of caffeine on myocardial stress testing using adenosine and dipyridamole in clinical cardiovascular medicine. The limited published data are conflicting, but some recent publications suggest that myocardial perfusion SPECT imaging using adenosine may not be clinically significantly altered by routine consumption of caffeine, such as a cup of coffee. Although prospective randomized studies would be required to obtain a definitive answer to this question, it appears on the basis of some of the studies reviewed in this article that caffeine consumption prior to myocardial perfusion imaging may not necessitate cancellation or rescheduling of adenosine stress testing.


Assuntos
Adenosina , Cafeína/farmacologia , Estimulantes do Sistema Nervoso Central/farmacologia , Circulação Coronária , Coração/diagnóstico por imagem , Vasodilatadores , Cafeína/metabolismo , Estimulantes do Sistema Nervoso Central/metabolismo , Dipiridamol/farmacocinética , Teste de Esforço , Coração/fisiopatologia , Humanos , Compostos Radiofarmacêuticos/farmacocinética , Radioisótopos de Tálio/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único
18.
Ann Nucl Med ; 22(4): 317-21, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18535883

RESUMO

OBJECTIVE: Prone thallium-201 ((201)Tl) myocardial perfusion single-photon emission computed tomography (SPECT) reduces false-positive rates when evaluating inferior wall abnormalities by minimizing diaphragmatic attenuation. The present study investigates the diagnostic validity of prone (201)Tl stress myocardial perfusion SPECT for detecting coronary artery disease in the inferior wall of the left ventricle in Japanese patients. METHODS: Of the 104 consecutive patients who underwent (201)Tl stress myocardial perfusion SPECT to diagnose coronary artery disease, we evaluated 46 who underwent image acquisition in both the supine and prone positions, and coronary angiography within 3 months thereafter. Images were acquired in the routine supine position immediately following (201)Tl (111 MBq) injection and 4 h following early acquisition. Images were acquired in the prone position only during the early phase following supine acquisition. We evaluated the SPECT images of the inferior half segments of the left ventricle using a five-point defect scoring system. According to the coronary angiographic findings, we investigated the diagnostic accuracy of stress-rest supine, stress supine, stress prone, and combined supine-prone images. Reduced uptake in the stress supine image of the combined images was considered as attenuation when uptake was normal in the prone image. RESULTS: The sensitivity of the stress-rest supine, stress supine, stress prone, and stress-combined supine-prone images was 77%, 86%, 55%, and 55%, and the specificity was 71%, 54%, 79%, and 83%, respectively. Diagnostic accuracy was the highest in stress-rest supine images. CONCLUSIONS: Prone images tended to improve the specificity of detecting coronary artery disease in the inferior wall, but not diagnostic accuracy compared with stress-rest supine images because of decreased sensitivity.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Decúbito Ventral , Decúbito Dorsal , Idoso , Idoso de 80 Anos ou mais , Protocolos Clínicos , Circulação Coronária , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/farmacocinética , Descanso , Sensibilidade e Especificidade , Radioisótopos de Tálio/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
19.
Ann Nucl Med ; 22(3): 221-4, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18498038

RESUMO

Chondromyxoid fibroma (CMF) is a benign bone tumor. However, it is sometimes difficult to distinguish this tumor from chondrosarcoma. We report a rare case arising from the proximal fibula, presenting multimodality imaging features. An 18-year-old man presented with a 2-year history of gradually increasing pain and swelling in his left knee. Radiograph showed an area of osteolysis with lobulation. Magnetic resonance (MR) imaging demonstrated that almost the whole lesion was enhanced with Gd-DTPA. Scintigraphy examination with (99m)Tc-biphosphonate showed strong accumulation in the periphery. On Ga-67-citrate scintigraphy, there was a little uptake. Thallium-201 scintigraphy showed strong accumulation of the whole lesion in early and late scans. The tumor was diagnosed as CMF by open biopsy. It is important that CMF is correctly distinguished from other tumors because this may be histologically overdiagnosed as chondrosarcoma. Contrast-enhanced MR imaging and thallium-201 scintigraphy may be useful to distinguish CMF from benign bone tumors or chondrosarcoma.


Assuntos
Condromatose/diagnóstico por imagem , Condrossarcoma/diagnóstico por imagem , Radioisótopos de Tálio/farmacocinética , Adolescente , Biópsia , Citratos/farmacocinética , Meios de Contraste/farmacocinética , Diagnóstico Diferencial , Difosfonatos/farmacocinética , Fibroma/diagnóstico por imagem , Fíbula/patologia , Gadolínio DTPA/farmacocinética , Gálio/farmacocinética , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética , Masculino , Osteólise/diagnóstico por imagem , Radiografia , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética , Compostos de Tecnécio/farmacocinética
20.
Ann Nucl Med ; 22(2): 115-22, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18311536

RESUMO

OBJECTIVE: The objective of the present study is to investigate the correlations across various types of interface software for (201)Tl gated myocardial perfusion SPECT (MPS) in calculating two common diastolic function parameters (DFx), peak-filling rates (PFR), and time-to-peak filling (TTPF). METHODS: A total of 109 patients (66 men and 43 women; age 35-78 years) were studied. All patients were classified into three groups (i.e., ND, no-defect group; SD, small-defect group; LD, large-defect group) to clarify the influence of perfusion defects possibly affecting the analysis. Two kinds of available software, namely, quantitative gated SPECT (QGS2) and perfusion and functional analysis for gated SPECT (pFAST2) with cardioGRAF were used to obtain PFR and TTPF. Finally, we analyzed the correlation between DFx obtained with the two different kinds of software. RESULTS: The values of LVEF, PFR, and TTPF were assessed in all patients. In both the ND (correlation coefficients were 0.92, 0.79, and 0.99, respectively) and SD groups (correlation coefficients were 0.74, 0.88, and 0.98, respectively), a strong correlation was observed. In contrast, PFR did not show a significant correlation in the LD group. CONCLUSIONS: With the two different kinds of software, QGS2 and pFAST2, the calculated PFR was almost equal and showed good correlations in both ND and SD groups. In contrast, the numerical value varied between the two methods, and its correlation was poor in the LD group. However, TTPF showed a good correlation regardless of the presence of perfusion defects, and the values were equal. TTPF was confirmed to be a stable diastolic index across the two kinds of software, QGS2 and pFAST2, in (201)Tl gated MPS.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta/métodos , Validação de Programas de Computador , Radioisótopos de Tálio/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Função Ventricular Esquerda , Adulto , Idoso , Débito Cardíaco , Diástole/fisiologia , Feminino , Imagem do Acúmulo Cardíaco de Comporta/instrumentação , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Valva Mitral , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...