Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.298
Filtrar
1.
Resuscitation ; 200: 110250, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38788794

RESUMO

INTRODUCTION: Cardiac arrest (CA) is the third leading cause of death, with persistently low survival rates despite medical advancements. This article evaluates the potential of emerging technologies to enhance CA management over the next decade, using predictions from the AI tools ChatGPT-4 and Gemini Advanced. METHODS: We conducted an exploratory literature review to envision the future of cardiopulmonary arrest (CA) management. Utilizing ChatGPT-4 and Gemini Advanced, we predicted implementation timelines for innovations in early recognition, CPR, defibrillation, and post-resuscitation care. We also consulted the AI to assess the consistency and reproducibility of the predictions. RESULTS: We extrapolate that healthcare may embrace new technologies, such as comprehensive monitoring of vital signs to activate the emergency system (wireless detectors, smart speakers, and wearable devices), use new innovative early CPR and early AED devices (robot CPR, wearable AEDs, and immersive reality), and post-resuscitation care monitoring (brain-computer interface). These technologies could enhance timely life-saving interventions for cardiac arrest. However, there are many ethical and practical challenges, particularly in maintaining patient privacy and equity. The two AI tools made different predictions, with a horizon for implementation ranging between three and eight years. CONCLUSION: Integrating advanced monitoring technologies and AI-driven tools offers hope in improving CA management. A balanced approach involving rigorous scientific validation and ethical oversight is necessary. Collaboration among technologists, medical professionals, ethicists, and policymakers is crucial to use these innovations ethically to reduce CA incidence and enhance outcomes. Further research is needed to enhance the reliability of AI predictive capabilities.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Humanos , Reanimação Cardiopulmonar/métodos , Reanimação Cardiopulmonar/instrumentação , Parada Cardíaca/terapia , Invenções , Previsões , Inteligência Artificial , Desfibriladores
2.
ASAIO J ; 70(7): e89-e91, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38277338

RESUMO

Left ventricular (LV) unloading has been shown to improve survival for patients requiring veno-arterial extracorporeal membrane oxygenation (VA ECMO) support for cardiogenic shock. A mortality benefit has been shown for ECMO and concomitant placement of a transcatheter unloading LV pump such as an Impella device (colloquially referred to as ECPELLA or ECMELLA) for patients resuscitated with VA ECMO after a short period of cardiac arrest. Despite the described benefit of LV unloading with VA ECMO for cardiopulmonary resuscitation, it remains unclear as to what criteria should be used and what other diagnostic and therapeutic adjuncts may be useful. We describe here the successful utilization of concomitant VA ECMO and Impella in a 43 year old male with acute heart failure and cardiac arrest. Distinguishing itself from the currently reported methods, our methodology incorporates transesophageal echocardiography (TEE) in the emergency department for rapid decision-making in addition to an automatic chest compression device, the Lund University Cardiac Assist System (LUCAS) device (Stryker, Portage, MI) as a bridge to LV unloading in a hybrid operating suite.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Humanos , Masculino , Oxigenação por Membrana Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/instrumentação , Adulto , Choque Cardiogênico/terapia , Ventrículos do Coração/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Ecocardiografia Transesofagiana/métodos , Parada Cardíaca/terapia , Reanimação Cardiopulmonar/métodos , Reanimação Cardiopulmonar/instrumentação
4.
Pediatr Res ; 95(1): 156-159, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37741932

RESUMO

BACKGROUND: High-quality chest compressions (CC) are an important factor of neonatal resuscitation. Mechanical CC devices may provide superior CC delivery and improve resuscitation outcomes. We aimed to compare the hemodynamic effects of CC delivered by machine and human using a neonatal piglet model. METHODS: Twelve asphyxiated piglets were randomized to receive CC during resuscitation using an automated mechanical CC device ("machine") or the two-thumb encircling technique ("human"). CC was superimposed with sustained inflations. RESULTS: Twelve newborn piglets (age 0-3 days, weight 2.12 ± 0.17 kg) were included in the study. Machine-delivered CC resulted in an increase in stroke volume, and minimum and maximum rate of left ventricle pressure change (dp/dtmin and dp/dtmax) compared to human-delivered CC. CONCLUSIONS: During machine-delivered CC, stroke volume and left ventricular contractility were significantly improved. Mechanical CC devices may provide improved cardiopulmonary resuscitation outcomes in neonatal cardiac arrest induced by asphyxia. IMPACT: Machine chest compression leads to changes in hemodynamic parameters during resuscitation of asphyxiated neonatal piglets, namely greater stroke volume and left ventricular contractility, compared with standard two-thumb compression technique. Mechanical chest compression devices may provide improved cardiopulmonary resuscitation outcomes in neonatal and pediatric asphyxia-induced cardiac arrest.


Assuntos
Asfixia , Reanimação Cardiopulmonar , Parada Cardíaca , Respiração Artificial , Animais , Humanos , Asfixia/terapia , Reanimação Cardiopulmonar/instrumentação , Reanimação Cardiopulmonar/métodos , Parada Cardíaca/terapia , Hemodinâmica , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Suínos , Animais Recém-Nascidos , Modelos Animais de Doenças
6.
JAMA ; 329(19): 1693-1694, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37103942

RESUMO

This JAMA Insights Clinical Update discusses the newer treatment option of extracorporeal cardiopulmonary resuscitation, particularly for patients with cardiac arrest who are not responsive to initial treatment.


Assuntos
Reanimação Cardiopulmonar , Oxigenação por Membrana Extracorpórea , Parada Cardíaca , Humanos , Reanimação Cardiopulmonar/instrumentação , Reanimação Cardiopulmonar/métodos , Parada Cardíaca/terapia , Parada Cardíaca Extra-Hospitalar/terapia , Resultado do Tratamento , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/métodos
8.
Actas dermo-sifiliogr. (Ed. impr.) ; 113(8): 808-811, sept. 2022. ilus
Artigo em Espanhol | IBECS | ID: ibc-208311

RESUMO

En el presente artículo de la serie «Seguridad en procedimientos dermatológicos» se aborda la reanimación cardiopulmonar básica (sin empleo de ningún dispositivo), instrumentalizada (usando un desfibrilador externo automático) y farmacológica (haciendo uso de adrenalina). Se plantean las recomendaciones actualizadas en 2021 del Consejo Europeo de Resucitación de forma resumida, con material gráfico que las sistematiza de forma estructurada (AU)


This article in the series on safety in dermatologic procedures covers the delivery of basic cardiopulmonary resuscitation (using no devices), instrumental resuscitation (using an automated external defibrillator), and pharmacological resuscitation (using adrenaline). We provide a brief overview of the updated 2021 European Resuscitation Council guidelines and offer an algorithm and visual aids to support recommended practices (AU)


Assuntos
Humanos , Reanimação Cardiopulmonar/instrumentação , Reanimação Cardiopulmonar/métodos , Algoritmos
9.
Actas dermo-sifiliogr. (Ed. impr.) ; 113(8): t808-t811, sept. 2022. ilus
Artigo em Inglês | IBECS | ID: ibc-208312

RESUMO

This article in the series on safety in dermatologic procedures covers the delivery of basic cardiopulmonary resuscitation (using no devices), instrumental resuscitation (using an automated external defibrillator), and pharmacological resuscitation (using adrenaline). We provide a brief overview of the updated 2021 European Resuscitation Council guidelines and offer an algorithm and visual aids to support recommended practices (AU)


En el presente artículo de la serie «Seguridad en procedimientos dermatológicos» se aborda la reanimación cardiopulmonar básica (sin empleo de ningún dispositivo), instrumentalizada (usando un desfibrilador externo automático) y farmacológica (haciendo uso de adrenalina). Se plantean las recomendaciones actualizadas en 2021 del Consejo Europeo de Resucitación de forma resumida, con material gráfico que las sistematiza de forma estructurada (AU)


Assuntos
Humanos , Reanimação Cardiopulmonar/instrumentação , Reanimação Cardiopulmonar/métodos , Algoritmos
11.
PLoS One ; 17(3): e0264774, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35239740

RESUMO

The Covid-19 outbreak challenged health systems around the world to design and implement cost-effective devices produced locally to meet the increased demand of mechanical ventilators worldwide. This study evaluates the physiological responses of healthy swine maintained under volume- or pressure-controlled mechanical ventilation by a mechanical ventilator implemented to bring life-support by automating a resuscitation bag and closely controlling ventilatory parameters. Physiological parameters were monitored in eight sedated animals (t0) prior to inducing deep anaesthesia, and during the next six hours of mechanical ventilation (t1-7). Hemodynamic conditions were monitored periodically using a portable gas analyser machine (i.e. BEecf, carbonate, SaO2, lactate, pH, PaO2, PaCO2) and a capnometer (i.e. ETCO2). Electrocardiogram, echocardiography and lung ultrasonography were performed to detect in vivo alterations in these vital organs and pathological findings from necropsy were reported. The mechanical ventilator properly controlled physiological levels of blood biochemistry such as oxygenation parameters (PaO2, PaCO2, SaO2, ETCO2), acid-base equilibrium (pH, carbonate, BEecf), and perfusion of tissues (lactate levels). In addition, histopathological analysis showed no evidence of acute tissue damage in lung, heart, liver, kidney, or brain. All animals were able to breathe spontaneously after undergoing mechanical ventilation. These preclinical data, supports the biological safety of the medical device to move forward to further evaluation in clinical studies.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Respiração Artificial/instrumentação , Ventiladores Mecânicos , Animais , Automação , Gasometria , COVID-19/complicações , COVID-19/patologia , COVID-19/fisiopatologia , Feminino , Hemodinâmica , Masculino , Respiração , SARS-CoV-2/fisiologia , Suínos
12.
Int Heart J ; 62(4): 879-884, 2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34276018

RESUMO

The frequencies of autonomous bystander-initiated cardiopulmonary resuscitation (CPR) and public access defibrillation have not yet been clarified. We aimed to evaluate the frequency of autonomous actions by citizens not having a duty to act.This retrospective observational study included patients who suffered an out-of-hospital cardiac arrest (OHCA) in Tokyo between January 1, 2013 and December 31, 2017. The Delphi method with a panel of 11 experts classified the locations of OHCA resuscitations into 3 categories as follows; autonomous, non autonomous, and undetermined. The locations determined as autonomous were further divided into 2 groups; home and other locations. Bystander-initiated CPR and application of an automated external defibrillator (AED) pad were evaluated in 43,460 patients with OHCA.Group A (non autonomous), group B (autonomous, not home), and group C (home), consisted of 7,352, 3,193, and 32,915 patients, respectively. Compared with group A, group B and group C had significantly lower rates of bystander-initiated CPR (group A, B, C; 68.3% versus 38.6% versus 23.9%) and AED pad application (groups A, B, C; 26.8% versus 15.1% versus 0.6%). In addition, multivariate analysis demonstrated that an autonomous location of resuscitation was independently associated with the frequencies of bystander-initiated CPR and AED pad application, even after adjusting for age, sex, and witness status.Autonomous actions by citizens were unacceptably infrequent. Therefore, the education and training of citizens is necessary to further enhance autonomous CPR.


Assuntos
Reanimação Cardiopulmonar/estatística & dados numéricos , Parada Cardíaca Extra-Hospitalar/terapia , Idoso , Idoso de 80 Anos ou mais , Reanimação Cardiopulmonar/instrumentação , Desfibriladores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tóquio
13.
Int J Med Sci ; 18(13): 2783-2788, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34220306

RESUMO

Background: The quality of cardiopulmonary resuscitation (CPR) is closely related to the survival rate of a patient, and it is crucial to maintain the quality of CPR during the ambulance journey to the receiving hospital. The purpose of this study was to investigate the effects of different stretcher bed heights on operator CPR quality. Methods: In this randomized crossover trial, 16 male emergency medical technicians-paramedics (EMT-Ps) performed continuous chest compressions on a hemimorphic mannequin for 5 minutes, alternating between the current height of the stretcher bed on the ambulance (38 ± 1 cm) (S-38) and the height of the participant's midpoint of the patella (S-knee), where the stretcher bed surface is. Results: According to the analysis of the quality of CPR exercises with two different stretcher bed heights at 5 minutes of continuous chest compression, the mean chest compression depth (CCD) of the S-38 position (53.81 ± 1.91 cm) was significantly lower than that of the S-knee (55.12 ± 2.03 cm; p < 0.001). The mean chest compression rate (CCR) of the S-38 position (111.44 ± 3.44 beats/min) was significantly higher than that of the S-knee (109.63 ± 4.46 beats/min; p = 0.027). The mean of total chest compressions (TCC) of the S-38 position (557.44 ± 16.81 times) was significantly higher than that of the S-knee (548.24 ± 19.40 times; p = 0.029). The rating of perceived exertion (RPE) of the S-38 position was significantly higher than that of the S-knee (12.75 ± 1.91 %; p = 0.015). Only the chest compression rebound rate (CCRR) (S-38: 97.56 ± 4.63 % vs. S-knee: 98.31 ± 1.89 %, p = 0.401) and the chest compression fraction (CCF) (S-38: 98.44 ± 0.81 % vs. S-knee: 98.44 ± 0.96 %, p = 1.000) did not reach a significant difference. Conclusion: When a resuscitator is performing chest compressions in a standing position in an ambulance, the excessive downward leaning of the resuscitator's upper body affects CPR quality and increases fatigue. This study has verified that setting the stretcher bed of the ambulance at the knee height of the EMTs provides better CPR quality and lower fatigue.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Auxiliares de Emergência/estatística & dados numéricos , Fadiga/prevenção & controle , Parada Cardíaca Extra-Hospitalar/terapia , Macas , Adulto , Ambulâncias , Estudos Cross-Over , Ergonomia , Fadiga/diagnóstico , Fadiga/epidemiologia , Fadiga/etiologia , Humanos , Masculino , Manequins , Treinamento por Simulação , Resultado do Tratamento
14.
Scand J Trauma Resusc Emerg Med ; 29(1): 79, 2021 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-34090500

RESUMO

BACKGROUND: Mechanical chest compression devices are accepted alternatives for cardiopulmonary resuscitation (CPR) under specific circumstances. Current devices lack prospective and comparative data on their specific cardiovascular effects and potential for severe thoracic injuries. OBJECTIVES: To compare CPR effectiveness and thoracic injuries of two mechanical chest compression devices in pigs. STUDY DESIGN: Prospective randomised trial. ANIMALS: Eighteen male German landrace pigs. METHODS: Ventricular fibrillation was induced in anaesthetised and instrumented pigs and the animals were randomised into two intervention groups. Mechanical CPR was initiated by means of LUCAS™ 2 (mCCD1) or Corpuls™ cpr (mCCD2) device. Advanced life support was applied for a maximum of 10 cycles and animals achieving ROSC were monitored for 8 h. Ventilation/perfusion measurements were performed and blood gas analyses were taken. Thoracic injuries were assessed via a standardised damage score. RESULTS: Five animals of the mCCD1 group and one animal of the mCCD2 group achieved ROSC (p = 0.048). Only the mCCD1 animals survived until the end of the monitoring period (p < 0.01). MCCD1 animals showed less pulmonary shunt (p = 0.025) and higher normal V/Q (p = 0.017) during CPR. MCCD2 animals showed significantly more severe thoracic injuries (p = 0.046). CONCLUSION: The LUCAS 2 device shows superior resuscitation outcomes and less thoracic injuries compared to Corpuls cpr when used for experimental CPR in juvenile pigs. Researchers should be aware that different mCCDs for experimental studies may significantly influence the respective outcome of resuscitation studies and affect comparability of different trials. Controlled human and animal CPR studies and a standardised post-resuscitation injury evaluation could help to confirm potential hazards. TRIAL REGISTRATION: Trial approval number: G16-1-042-E4.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Traumatismos Torácicos , Animais , Humanos , Masculino , Gasometria , Reanimação Cardiopulmonar/efeitos adversos , Reanimação Cardiopulmonar/instrumentação , Parada Cardíaca/terapia , Parada Cardíaca/veterinária , Pressão , Estudos Prospectivos , Suínos , Traumatismos Torácicos/epidemiologia , Traumatismos Torácicos/veterinária , Tórax , Fibrilação Ventricular
15.
Scand J Trauma Resusc Emerg Med ; 29(1): 84, 2021 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-34187532

RESUMO

BACKGROUND: Cardiopulmonary resuscitation in mountain environment is challenging. Continuous chest compressions during transport or hoist rescue are almost impossible without mechanical chest compression devices. Current evidence is predominantly based on studies conducted by urbane ambulance service. Therefore, we aimed to investigate the feasibility of continuous mechanical chest compression during alpine terrestrial transport using three different devices. METHODS: Randomized triple crossover prospective study in an alpine environment. Nineteen teams of the Austrian Mountain Rescue Service trained according to current ERC guidelines performed three runs each of a standardised alpine rescue-scenario, using three different devices for mechanical chest compression. Quality of CPR, hands-off-time and displacement of devices were measured. RESULTS: The primary outcome of performed work (defined as number of chest compressions x compression depth) was 66,062 mm (2832) with Corpuls CPR, 65,877 mm (6163) with Physio-Control LUCAS 3 and 40,177 mm (4396) with Schiller Easy Pulse. The difference both between LUCAS 3 and Easy Pulse (Δ 25,700; 95% confidence interval 21,118 - 30,282) and between Corpuls CPR and Easy Pulse (Δ 25,885; 23,590 - 28,181) was significant. No relevant differences were found regarding secondary outcomes. CONCLUSION: Mechanical chest compression devices provide a viable option in the alpine setting. For two out of three devices (Corpuls CPR and LUCAS 3) we found adequate quality of CPR. Those devices also maintained a correct placement of the piston even during challenging terrestrial transport. Adequate hands-off-times and correct placement could be achieved even by less trained personnel.


Assuntos
Ambulâncias , Reanimação Cardiopulmonar/instrumentação , Parada Cardíaca Extra-Hospitalar/terapia , Adulto , Áustria , Estudos Cross-Over , Desenho de Equipamento , Feminino , Humanos , Masculino , Pressão , Estudos Prospectivos , Tórax
16.
Int. j. cardiovasc. sci. (Impr.) ; 34(3): 315-318, May-June 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1250096

RESUMO

Abstract Mechanical ventilation in prone position is an alternative strategy for patients with acute respiratory discomfort syndrome (ARDS) to improve oxygenation in situations when traditional ventilation modalities have failed. However, due to the significant increase in ARDS cases during the SARS-CoV-2 pandemic and the experimental therapeutic use of potentially arrhythmogenic drugs, cardiopulmonary resuscitation in this unusual position could be needed. Therefore, we will review the available scientific evidence of cardiopulmonary resuscitation in prone position.


Assuntos
Humanos , Decúbito Ventral , Reanimação Cardiopulmonar/métodos , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Cardioversão Elétrica/métodos , Reanimação Cardiopulmonar/instrumentação
17.
Sci Rep ; 11(1): 9858, 2021 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-33972647

RESUMO

Early recognition and rapid initiation of high-quality cardiopulmonary resuscitation (CPR) are key to maximising chances of achieving successful return of spontaneous circulation in patients with out-of-hospital cardiac arrests (OHCAs), as well as improving patient outcomes both inside and outside hospital. Mechanical chest compression devices such as the LUCAS-2 have been developed to assist rescuers in providing consistent, high-quality compressions, even during transportation. However, providing uninterrupted and effective compressions with LUCAS-2 during transportation down stairwells and in tight spaces in a non-supine position is relatively impossible. In this study, we proposed adaptations to the LUCAS-2 to allow its use during transportation down stairwells and examined its effectiveness in providing high-quality CPR to simulated OHCA patients. 20 volunteer emergency medical technicians were randomised into 10 pairs, each undergoing 2 simulation runs per experimental arm (LUCAS-2 versus control) with a loaded Resusci Anne First Aid full body manikin weighing 60 kg. Quality of CPR compressions performed was measured using the CPRmeter placed on the sternum of the manikin. The respective times taken for each phase of the simulation protocol were recorded. Fisher's exact tests were used to analyse categorical variables and median test to analyse continuous variables. The LUCAS-2 group required a longer time (~ 35 s) to prepare the patient prior to transport (p < 0.0001) and arrive at the ambulance (p < 0.0001) compared to the control group. The CPR quality in terms of depth and rate for the overall resuscitation period did not differ significantly between the LUCAS-2 group and control group, though there was a reduction in both parameters when evaluating the device's automated compressions during transport. Nevertheless, the application of the LUCAS-2 device yielded a significantly higher chest compression fraction of 0.76 (p < 0.0001). Our novel adaptations to the LUCAS-2 device allow for uninterrupted compressions in patients being transported down stairwells, thus yielding better chest compression fractions for the overall resuscitation period. Whether potentially improved post-OHCA survival rates may be achieved requires confirmation in a real-world scenario study.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Parada Cardíaca Extra-Hospitalar/terapia , Treinamento por Simulação/métodos , Transporte de Pacientes/métodos , Auxiliares de Emergência , Feminino , Humanos , Masculino , Manequins , Ombro , Macas , Resultado do Tratamento
19.
Scand J Trauma Resusc Emerg Med ; 29(1): 39, 2021 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-33632277

RESUMO

BACKGROUND: The effect of mechanical CPR is diversely described in the literature. Different mechanical CPR devices are available. The corpuls cpr is a new generation of piston-driven devices and was launched in 2015. The COMPRESS-trial analyzes quality of chest compression and CPR-related injuries in cases of mechanical CPR by the corpuls cpr and manual CPR. METHODS: This article describes the design and study protocol of the COMPRESS-trial. This observational multi-center study includes all patients who suffered an out-of-hospital cardiac arrest (OHCA) where CPR is attempted in four German emergency medical systems (EMS) between January 2020 and December 2022. EMS treatment, in-hospital-treatment and outcome are anonymously reported to the German Resuscitation Registry (GRR). This information is linked with data from the defibrillator, the feedback system and the mechanical CPR device for a complete dataset. Primary endpoint is chest compression quality (complete release, compression rate, compression depth, chest compression fraction, CPR-related injuries). Secondary endpoint is survival (return of spontaneous circulation (ROSC), admission to hospital and survival to hospital discharge). The trial is sponsored by GS Elektromedizinische Geräte G. Stemple GmbH. DISCUSSION: This observational multi-center study will contribute to the evaluation of mechanical chest compression devices and to the efficacy and safety of the corpuls cpr. TRIAL REGISTRATION: DRKS, DRKS-ID DRKS00020819 . Registered 31 July 2020.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Reanimação Cardiopulmonar/métodos , Parada Cardíaca Extra-Hospitalar/terapia , Avaliação de Resultados em Cuidados de Saúde , Qualidade da Assistência à Saúde , Adulto , Serviços Médicos de Emergência , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros
20.
Saudi Med J ; 42(1): 75-81, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33399174

RESUMO

OBJECTIVES: To compare the efficacies of various chest compression procedures performed on a stretcher during dynamic transport of patients with in-hospital cardiac arrest. Methods: This prospective and randomized cross-over study used manikins. Practitioners were asked to perform chest compressions on a manikin placed on a moving stretcher for 2 minutes. Cardiopulmonary resuscitation (CPR)  procedures were included the following 3 types: i) CPR-walking (CPR-W) ii) CPR-straddling (CPR-S), and iii) CPR-mechanical chest compression device (CPR-MCCD). Demographic data of the participants, CPR quality indicators, the time between the start command and first compression, level of difficulty, and the distance covered by the stretcher for the duration of each application were recorded. RESULTS: Thirty-two physicians (9 female, 23 male), participated in this study. The CPR-MCCD procedure was the most effective for all parameters, except the time between the start command and first compression. On the other hand, the compression rate at optimal depth, CPR success score, distance covered, and level of difficulty parameters were significantly favored in the CPR-S group, when compared to the CPR-W group (p less than 0.001, all comparisons). CONCLUSIONS: It is possible to perform high-quality chest compressions during patient transport using the CPR-MCCD method. The CPR-S method allowed practitioners to perform higher-quality chest compressions compared to CPR-W.


Assuntos
Reanimação Cardiopulmonar/métodos , Serviços Médicos de Emergência/métodos , Parada Cardíaca/terapia , Hospitais , Manequins , Macas , Adulto , Reanimação Cardiopulmonar/instrumentação , Estudos Cross-Over , Feminino , Humanos , Masculino , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...