1.
JBJS Case Connect ; 10(2): e19.00542, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32649146

RESUMO

CASE: A 45-year old man presented with a right open tibial fracture with a prominent, fixed deformity because of a retained right tibial intramedullary nail from a previous tibial fracture. After multiple futile intraoperative attempts to extract the bent nail, it was finally sectioned using an industrial drill bit that permitted its removal and revision tibial nailing. CONCLUSIONS: A tibial fracture resulting in a retained, bent nail presents unique challenges for nail extraction and subsequent exchange nailing. Failed implant removal can be limited by the equipment available in the operating theater. In this setting, the judicious use of inexpensive industrial materials and instruments may be effective in select cases.


Assuntos
Pinos Ortopédicos , Remoção de Dispositivo/instrumentação , Fraturas Expostas/diagnóstico por imagem , Relesões/diagnóstico por imagem , Fraturas da Tíbia/diagnóstico por imagem , Remoção de Dispositivo/economia , Fíbula/lesões , Fixação Intramedular de Fraturas , Fraturas Expostas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Relesões/cirurgia , Fraturas da Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...