Optom Vis Sci ; 101(5): 272-275, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38857039

RESUMO

SIGNIFICANCE: Loss of homeostasis and chronic inflammation result in ocular surface damage in dry eyes, which is also associated with corneal thinning in established cases. Yet, the correlation between corneal thickness and new cases of dry eyes remains inadequately supported by evidence. PURPOSE: This study aimed to compare the central corneal thickness of new cases of dry eyes to that of age- and gender-matched controls. METHODS: A total of 45 dry eye patients were compared with 61 age- and gender-matched non-dry eye individuals. The Ocular Surface Disease Index (OSDI) questionnaire was used to evaluate symptoms, and the central corneal thickness was measured with a Nidek CEM-530 specular microscope. Patients were grouped based on disease severity (OSDI scores), and the clinical findings were compared between groups for slit-lamp examinations, Schirmer's I test, and tear film breakup time. RESULTS: The median age of patients was 25.0 (interquartile range [IQR], 20.0 to 32.0) and 27.0 (IQR, 20.0 to 32.0) years in the control and dry eye groups, respectively (p=0.63). The median (IQR) values of the OSDI scores, tear film breakup time scores, and Schirmer's test measurements in the control groups were 10.4 (8.3 to 10.4), 12.0 (11.0 to 14.0) seconds, and 16.0 (13.5 to 19.5) mm, respectively, which differed from the dry eye groups (p<0.0001). These values in the dry eye group were 29.1 (25.0 to 39.5), 4.0 (3.0 to 8.0) seconds, and 8.0 (3.5 to 11.0) mm, respectively. Patients with dry eyes had lower central corneal thickness than controls (p<0.01). The mean ± standard deviation central corneal thicknesses in patients with dry eyes and the control group were 520.3 ± 26.8 and 545.3 ± 18.8 µm, respectively. CONCLUSIONS: The central corneal thickness in dry eyes was significantly reduced compared with the control group. These findings may be useful in monitoring and managing dry eyes and should be considered in intraocular pressure measurements and refractive surgical procedures.


Assuntos
Córnea , Síndromes do Olho Seco , Humanos , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/diagnóstico , Feminino , Masculino , Córnea/patologia , Córnea/diagnóstico por imagem , Estudos de Casos e Controles , Adulto , Adulto Jovem , Lágrimas/fisiologia , Lágrimas/metabolismo , Inquéritos e Questionários , Paquimetria Corneana , Pessoa de Meia-Idade
2.
Int Ophthalmol ; 44(1): 211, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696090

RESUMO

PURPOSE: To evaluate the effects of sodium hyaluronate drops on dry eye parameters and corneal epithelial thickness following cataract surgery. METHODS: The study included 84 patients who underwent uncomplicated phacoemulsification. In Group A, 0.15% sodium hyaluronate drops were added to the postoperative antibiotic/anti-inflammatory treatment. In Group B, only antibiotic/anti-inflammatory treatment was applied. Preoperatively and at 1 week and 1 month postoperatively, all the patients were evaluated in respect of tear break-up time (TBUT), the Schirmer test under anesthesia, the corneal fluorescein staining (CFS) score, mean central corneal thickness (CCT) and mean central corneal epithelial thickness (CCET), and the two groups were compared. RESULTS: A statistically significant difference was determined between the two groups at postoperative 1 month in respect of TBUT, Schirmer test, CFS score, and CCET (p < 0.01). In Group A, a statistically significant increase was determined in the TBUT and Schirmer values at 1 month postoperatively (p < 0.01, p = 0.01, respectively) and in Group B, these values were decreased compared to preoperatively (p < 0.01). The CCET was determined to be significantly thinner in Group B 1 month postoperatively (p < 0.01). A significant increase in CCT was observed in both groups at postoperative 1 week (p < 0.01) and preoperative values were reached at 1 month postoperatively. CONCLUSION: In the patient group using sodium hyaluronate, significant differences were determined in all dry eye parameters and CCET. The use of hyaluronate sodium drops after cataract surgery was seen to improve dry eye parameters and contribute to a healthy ocular surface by ensuring continuity of the corneal epithelium.


Assuntos
Síndromes do Olho Seco , Epitélio Corneano , Ácido Hialurônico , Soluções Oftálmicas , Facoemulsificação , Humanos , Ácido Hialurônico/administração & dosagem , Síndromes do Olho Seco/tratamento farmacológico , Síndromes do Olho Seco/diagnóstico , Feminino , Masculino , Idoso , Epitélio Corneano/efeitos dos fármacos , Epitélio Corneano/patologia , Pessoa de Meia-Idade , Soluções Oftálmicas/administração & dosagem , Facoemulsificação/métodos , Viscossuplementos/administração & dosagem , Estudos Prospectivos , Lágrimas/metabolismo , Complicações Pós-Operatórias/prevenção & controle , Extração de Catarata/métodos
3.
Sci Rep ; 14(1): 11723, 2024 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-38778145

RESUMO

In the realm of ophthalmology, precise measurement of tear film break-up time (TBUT) plays a crucial role in diagnosing dry eye disease (DED). This study aims to introduce an automated approach utilizing artificial intelligence (AI) to mitigate subjectivity and enhance the reliability of TBUT measurement. We employed a dataset of 47 slit lamp videos for development, while a test dataset of 20 slit lamp videos was used for evaluating the proposed approach. The multistep approach for TBUT estimation involves the utilization of a Dual-Task Siamese Network for classifying video frames into tear film breakup or non-breakup categories. Subsequently, a postprocessing step incorporates a Gaussian filter to smooth the instant breakup/non-breakup predictions effectively. Applying a threshold to the smoothed predictions identifies the initiation of tear film breakup. Our proposed method demonstrates on the evaluation dataset a precise breakup/non-breakup classification of video frames, achieving an Area Under the Curve of 0.870. At the video level, we observed a strong Pearson correlation coefficient (r) of 0.81 between TBUT assessments conducted using our approach and the ground truth. These findings underscore the potential of AI-based approaches in quantifying TBUT, presenting a promising avenue for advancing diagnostic methodologies in ophthalmology.


Assuntos
Aprendizado Profundo , Síndromes do Olho Seco , Lágrimas , Síndromes do Olho Seco/diagnóstico , Humanos , Reprodutibilidade dos Testes , Gravação em Vídeo
4.
Ophthalmic Physiol Opt ; 44(5): 876-883, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38712751

RESUMO

OBJECTIVE: This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort. METHODS: Neophyte CL wearers (n = 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (n = 24) or control group (n = 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between -8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1-month sessions, the Dry Eye Questionnaire 5 (DEQ-5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit-lamp with Tearscope Plus attached, fluorescein break-up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light. RESULTS: At the baseline session, LWE showed a negative correlation with DEQ-5 (r = -0.37, p = 0.02). Significant differences in FBUT and LWE (p = 0.04) and a positive correlation between LWE and DEQ-5 (r = 0.49, p = 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ-5, FBUT and LWE (all p ≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ-5, FBUT and LWE (all p ≤ 0.02) but no significant variation in the control group (all p ≥ 0.11). CONCLUSION: The presence of LWE was significantly correlated with higher symptom values in the DEQ-5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.


Assuntos
Lentes de Contato Hidrofílicas , Equipamentos Descartáveis , Síndromes do Olho Seco , Lágrimas , Humanos , Masculino , Feminino , Lágrimas/fisiologia , Lágrimas/metabolismo , Adulto Jovem , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/diagnóstico , Adulto , Erros de Refração/terapia , Erros de Refração/fisiopatologia , Silicones , Adolescente , Inquéritos e Questionários , Doenças Palpebrais/fisiopatologia , Doenças Palpebrais/terapia , Concentração Osmolar
5.
Int Ophthalmol ; 44(1): 215, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38705919

RESUMO

PURPOSE: There is limited literature on the ocular manifestations in patients with psoriasis. Therefore, this study aimed to identify the prevalence of and factors associated with ocular manifestations in adults with psoriasis. METHODS: This cross-sectional study included Brazilian adults with psoriasis. The dermatological evaluation included diagnosis, clinical form, Psoriasis Area and Severity Index (PASI) measurement, and location of the lesions. Patients underwent a full ophthalmological examination, including the Schirmer I test, Rose Bengala staining, and tear breakup time tests. The results were analyzed using chi-square and Pearson's linear correlation tests. RESULTS: Of the 130 patients assessed, 118 (90.8%) exhibited ocular abnormalities, with meibomian gland dysfunction (MGD) being the most prevalent (59.2%), followed by dry eye disease (DED) (56.2%). A significant correlation was observed between MGD and PASI (p = 0.05), and between MGD and certain treatment modalities. DED was significantly associated with PASI (p < 0.05). Concurrent use of acitretin was identified as an independent predictor of MGD (odds ratio [OR] = 3.5, p < 0.05), whereas PASI was a protective factor against DED (OR = 0.39, p < 0.01). CONCLUSION: Given the high prevalence of eye disease among individuals with psoriasis, routine ophthalmological assessments are recommended to prevent possible ocular complications.


Assuntos
Síndromes do Olho Seco , Psoríase , Humanos , Estudos Transversais , Masculino , Psoríase/epidemiologia , Psoríase/complicações , Feminino , Brasil/epidemiologia , Adulto , Pessoa de Meia-Idade , Prevalência , Síndromes do Olho Seco/epidemiologia , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/diagnóstico , Disfunção da Glândula Tarsal/epidemiologia , Disfunção da Glândula Tarsal/diagnóstico , Disfunção da Glândula Tarsal/etiologia , Índice de Gravidade de Doença , Idoso , Adulto Jovem
7.
Int Ophthalmol ; 44(1): 190, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652333

RESUMO

PURPOSE: Somatization is an important mental process that may causes medically unexplained and treatment-resistant somatic symptoms. The aim of the study is assess the presence of somatization in patients with dry eye disease (DED). METHODS: Eighty-eight patients with no objective DED finding and ongoing DED treatment were included in this prospective and observational study. Patients with subjective symptoms formed the symptom group and patients without subjective symptoms formed the control group. All patients were scored with the Turkish version of the Ocular Surface Disease Index (OSDI), Hamilton Depression Rating Scale (HAM-D), Hamilton Anxiety Rating Scale (HAM-A), Symptom Checklist-90-R (SCL-90R) somatization subscale, Toronto Alexithymia Scale (TAS), Pain Catastrophizing Scale (PCS), and Symptom Interpretation Questionnaire (SIQ). RESULTS: Mean OSDI score was significantly higher in the symptom group than in the control group. The mean HAM-D and HAM-A outcomes did not differ between the groups. The mean SCL-90R somatization subscale, TAS, and PCS scores were significantly higher in the symptom group than in the control group. In the SIQ, somatic attributional style score was significantly higher in the symptom group than in the control group. The SCL-90R somatization subscale, PCS, and somatic attributional style scores had positive and mild-moderate correlation with OSDI scores in the symptom group. The TAS score had positive and moderate correlation with OSDI scores in all sample analyses. CONCLUSION: Somatization should be considered in patients with DED with chronic ocular surface symptoms. Presence of subjective symptoms resistant to treatment may be an indicator of somatization.


Assuntos
Síndromes do Olho Seco , Transtornos Somatoformes , Humanos , Síndromes do Olho Seco/psicologia , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Transtornos Somatoformes/psicologia , Transtornos Somatoformes/diagnóstico , Adulto , Inquéritos e Questionários , Idoso
8.
J Pak Med Assoc ; 74(3): 599-562, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38591297

RESUMO

This observational study aimed to evaluate the use of a single portable device to assess the non-invasive tear break-up time (NITBUT), tear meniscus height (TMH), and lipid layer patterns (LLP) in young females with refractive errors (REs). The study was conducted at the College of Applied Medical Science (Female campus), Riyadh, Saudi Arabia between January 5, 2021 to May 15, 2021. Forty young females, with mean age of 23.0± 4.3 years with REs (-2.53 ± 2.05 D) and 40 females, mean age 23.8± 4.5 years with healthy eyes were recruited. The tests were administered in the following order: Ocular Surface Disease Index (OSDI), followed by NITBUT, TMH, and LLP. Significant differences (via Mann-Whitney U test) were noted in the median ocular surface disease index (OSDI; p˂0.001), NITBUT (p=0.035), TMH (p=0.009), and LLP (p˂0.001) scores between the study and control groups. Females with REs have significantly lower lipid layer, TMH, and NITBUT scores than those with healthy eyes.


Assuntos
Síndromes do Olho Seco , Lacerações , Erros de Refração , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Lágrimas , Erros de Refração/diagnóstico , Síndromes do Olho Seco/diagnóstico , Lipídeos
9.
Int Ophthalmol ; 44(1): 193, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38653918

RESUMO

PURPOSE: This study evaluated the tear film stability in patients with symptoms of dry eye after installation of dual polymer hydroxypropyl guar/sodium hyaluronate (DPHG/SH) vs single polymer SH. METHODS: Patients with recently diagnosed mild to moderate dry eye disease (OSDI score 23-32 points) were included. For each patient, the right eye was randomized to receive DPHG/SH or 0.15% SH. Just after the administration of the drop to the right eye, the fellow eye received the other eye drop. The first non-invasive Keratograph first break-up time (NIKBUT), average NIKBUT and tear meniscus height (TMH) were measured before administration of the eye drops, at 1-min, 15 min, 30 min, 60 min, 90 min, and 120 min after instillation. RESULTS: A total of 29 patients aged 22.8 ± 2.2 years participated in the study (21 women). No differences between the eye receiving DPHG/SH and single polymer SH were observed for the first NIKBUT (p = 0.45) and average NIKBUT (p = 0.24) variables at any time point. Both DPHG/SH and single polymer SH increased the TMH (p of time effect < 0.001), but with no difference between groups (p = 0.95). CONCLUSION: Both DPHG/SH and single polymer SH solutions provide lubrication of the eye surface, however, with no difference in NIKBUT and TMH evaluations for up to two hours following administration.


Assuntos
Síndromes do Olho Seco , Ácido Hialurônico , Soluções Oftálmicas , Lágrimas , Humanos , Síndromes do Olho Seco/tratamento farmacológico , Síndromes do Olho Seco/diagnóstico , Feminino , Ácido Hialurônico/administração & dosagem , Masculino , Soluções Oftálmicas/administração & dosagem , Adulto Jovem , Adulto , Polissacarídeos/administração & dosagem , Polímeros , Viscossuplementos/administração & dosagem , Estudos Prospectivos
10.
PLoS One ; 19(4): e0301067, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38687717

RESUMO

OBJECTIVES: To develop a Thai version of the American Society of Cataract and Refractive Surgery (ASCRS)-modified Standard Patient Evaluation of Eye Dryness (SPEED) II© preoperative ocular surface disease (OSD) questionnaire (ASCRS SPEED II-Thai) and evaluate its validity and reliability in Thai cataract surgery candidates. METHODS: The original English version of the questionnaire was translated and adapted cross-culturally to Thai language. The ASCRS SPEED II-Thai was evaluated for content validity, internal consistency, and test-retest reliability. Five experts in the ocular surface field critically reviewed the ASCRS SPEED II-Thai to measure the content validity indexes (CVI). A total of 105 cataract surgery candidates were recruited from an ophthalmology clinic to complete the questionnaire. Cronbach's alpha and intraclass correlation coefficient (ICC) were calculated to assess internal consistency and test-retest reliability, respectively. RESULTS: During the translation and cross-cultural adaptation processes, only two minor modifications were made to the original version for clarification without changing their meaning. All items in the ASCRS SPEED II-Thai had an item-level CVI of 1.00, representing complete agreement among content experts. The scale-level CVI was 1.00, indicating excellent content validity of the questionnaire. The participants found no difficulty in understanding each question in the pilot test. Cronbach's alpha for the ASCRS SPEED II-Thai was 0.82, indicating good internal consistency. The test-retest reliability was good to excellent, with ICC values ranging from 0.83 to 1.00 (P < 0.001). CONCLUSIONS: The ASCRS SPEED II-Thai is a valid clinical tool with adequate reliability for preoperative OSD screening among Thai cataract surgery candidates.


Assuntos
Extração de Catarata , Humanos , Inquéritos e Questionários , Tailândia , Feminino , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Idoso , Síndromes do Olho Seco/diagnóstico , Catarata , Período Pré-Operatório , Traduções , População do Sudeste Asiático
11.
J Refract Surg ; 40(4): e229-e238, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593259

RESUMO

PURPOSE: To evaluate the effects of topical 0.05% cyclosporine A on Ocular Surface Disease Index (OSDI) score and ocular surface parameters after small incision lenticule extraction (SMILE) for myopia. METHODS: In this study, 151 patients who underwent SMILE were randomized into the control group (71 eyes) and the 0.05% cyclosporine A group (80 eyes). Both groups received standard treatment during the 1 month after SMILE. Over the next 3 months, The control group continued standard therapy (0.3% sodium hyaluronate) and the 0.05% cyclosporine A group received additional 0.05% cyclosporine A. OSDI total and subscale scores, non-invasive tear break-up time (NIBUT), tear lipid layer thickness (LLT), and tear meniscus height (TMH) were assessed preoperatively and postoperatively. RESULTS: Compared to baseline, the OSDI scores significantly increased in both groups (P < .001). The 0.05% cyclosporine A group exhibited lower OSDI total scores after administering 0.05% cyclosporine A versus the control group (P = .026). At 1 month of follow-up, NIBUT, LLT, and TMH values significantly decreased in both groups compared to baseline (P < .05). The 0.05% cyclosporine A group exhibited higher NIBUT, LLT, and TMH versus the control group, returning to preoperative values after 2 months. Overall, the OSDI total score and NIBUT values during follow-up were not significantly different between the two groups; however, the LLT and TMH values were significantly different between the two groups (P < .001 and .041, respectively) by repeated measures analysis of variance. CONCLUSIONS: Topical 0.05% cyclosporine A was effective in relieving subjective dry eye symptoms and maintaining ocular surface stability in the early postoperative period of SMILE. [J Refract Surg. 2024;40(4):e229-e238.].


Assuntos
Síndromes do Olho Seco , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Ciclosporina/uso terapêutico , Miopia/cirurgia , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/tratamento farmacológico , Síndromes do Olho Seco/etiologia , Lágrimas
12.
Cont Lens Anterior Eye ; 47(3): 102162, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38565442

RESUMO

PURPOSE: To investigate if there is a visible difference in meibomian gland (MG) length between images captured with the Visante optical coherence tomography (OCT; wavelength = 1,310 nm) and the OCULUS Keratograph 5M (K5M; wavelength = 880 nm). METHODS: Adults between 18 and 40 years were recruited. Baseline dry eye disease was evaluated with the Standard Patient Evaluation of Eye Dryness (SPEED) and tear meniscus height and tear breakup time with the K5M. Right upper and lower eyelid MGs were imaged with the K5M and Visante OCT. Each image was graded with the 0 to 3 meiboscore scale. The central 5 MGs were evaluated with ImageJ for percent gland length visibility. RESULTS: Thirty participants were analyzed with a median (interquartile range [IQR]) age of 23.0 (5.0) years (53.3 % female). Overall, participants were asymptomatic and had normal tear films. Meiboscores based on K5M and Visante OCT was significantly different for the lower eyelid (0[1] vs 1[2]; p = 0.007) but not the upper eyelid (0[1] vs 0[1]; p = 1.00). The mean percent gland visibility of the upper eyelid (82.7[9.6] vs 75.2[13.5]; p < 0.001) and the lower eyelid (81.2[12.7] vs 64.1[17.6]; p < 0.001) were significantly greater on the Visante OCT than the K5M images, respectively. CONCLUSION: OCT images had significantly greater percent visible MG lengths than the K5M images. This suggests viable segments of the MGs may be missed with typical imaging, which may explain how it is possible that studies have found less post-treatment MG atrophy.


Assuntos
Síndromes do Olho Seco , Glândulas Tarsais , Lágrimas , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/patologia , Feminino , Masculino , Adulto , Síndromes do Olho Seco/diagnóstico por imagem , Síndromes do Olho Seco/diagnóstico , Adulto Jovem , Lágrimas/química , Adolescente , Reprodutibilidade dos Testes
13.
Cont Lens Anterior Eye ; 47(3): 102164, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38594154

RESUMO

PURPOSE: To determine the changes in keratometry measurements and refraction in patients having the thermo-mechanical periorbital skin treatment, Tixel®, to treat dry eye disease (DED). METHODS: A multi-centre, prospective, non-masked study was conducted. DED patients were recruited in 3 international centres and were evaluated in 5 visits separated by an interval of 2 weeks except for the last visit which took place after 18 weeks from visit 1. The same clinical examination was performed at all visits: OSDI questionnaire, tear stability, keratometry, best corrected visual acuity and refraction. Tixel® treatment was applied at the first 3 visits. RESULTS: 89 participants (24 males/65 females; mean age: 55.0 ± 14.2 years) were included: 20 presented moderate DED symptoms and 69 severe DED symptoms. Significant differences were found for the spherocylindrical refraction (vector analysis) between visit 1 and visits 2 and 3. Following cumulative analysis, 11.86 % and 16.94 % of participants had more than 0.5 dioptre (D) change in mean keratometry and keratometric astigmatism, respectively, at 3 months post-treatment. A total of 5.40 % had a sphere and cylinder change greater than 0.50D and 16.21 % had the axis changed more than 10 degrees (vector analysis). These changes were particularly significant in patients with severe DED symptoms. CONCLUSIONS: Keratometry readings and refraction can change following thermo-mechanical skin treatment for DED, especially in those patients with severe DED symptoms. This should be considered as potential errors in intraocular lens calculations may be induced.


Assuntos
Extração de Catarata , Síndromes do Olho Seco , Refração Ocular , Acuidade Visual , Humanos , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/terapia , Síndromes do Olho Seco/diagnóstico , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Prospectivos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Idoso , Adulto , Córnea/fisiopatologia
14.
Cont Lens Anterior Eye ; 47(3): 102168, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38641524

RESUMO

BACKGROUND AND OBJECTIVES: Dry eye disease (DED) is increasingly prevalent, resultinginhigher morbidityamong children. This study evaluates the impact of DED severity on visual quality using double-pass technology, focusing on dynamic observation of the ocular light scatter in pediatric DED cases. METHOD: In this non-interventional, cross-sectional study, a mild DED group (37 cases, 37 eyes), a moderate DED group (40 cases, 40 eyes), and a control group of healthy children (35 cases, 35 eyes) were examined. Measurements included the Schirmer I test, tear film break-up time (BUT), and vision-related quality of life assessments using the Modified Ocular Surface Disease Index (OSDI) questionnaires. Participants underwent visual quality analysis using double-pass technology, which measured the modulation transfer function cut-off frequency value, Strehl ratio, objective scatter index (OSI), and OQAS-II value (OQAS-II value 100%, OQAS-II value 20%, and OQAS-II value 9%) under natural conditions. Additionally, dynamic changes in OSI post-blinking, Tear film mean-OSI , and the corresponding standard deviation OSI were recorded. RESULTS: Statistically significant differences were observed among the groups in modulation transfer function cutoff, Strehl ratio, OSI, OQAS-II value 100 %, OQAs-II value 20 %, OQAs-II value 9 %, tear film mean OSI, and standard deviation OSI (P < 0.05). As DED severity increased, tear film mean OSI significantly rose, while modulation transfer function cutoff, strehl ratio, OQAS-II value 100 %, OQAS-II value 20 %, OQAS-II value 9 % notably declined. All optical quality parameters were correlated with BUT, with no association observed with age, sex, or Schirmer I test. CONCLUSION: Dual-channel technology objectively assesses visual quality in pediatric DED, demonstrating that tear film scattering significantly affects retinal imaging and visual quality in children with DED.


Assuntos
Síndromes do Olho Seco , Qualidade de Vida , Humanos , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/diagnóstico , Feminino , Estudos Transversais , Masculino , Criança , Retina/diagnóstico por imagem , Lágrimas/fisiologia , Lágrimas/química , Lágrimas/metabolismo , Adolescente , Inquéritos e Questionários , Acuidade Visual/fisiologia
15.
Korean J Ophthalmol ; 38(3): 227-235, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38665113

RESUMO

PURPOSE: In the present study, we introduce human lacrimal gland imaging using an ultrasound biomicroscopy (UBM) with a soft cover and show their findings. METHODS: The representative UBM findings of palpebral lobes in seven subjects (four with non-Sjögren dry eye syndrome, one with Sjögren syndrome, and two healthy subjects) were described in this study. To prolapse the palpebral lobe, the examiner pulled the temporal part of the upper eyelid in the superotemporal direction and directed the subject to look in the inferonasal direction. We scanned the palpebral lobes longitudinally and transversely using UBM. We used an Aviso UBM with a 50 MHz linear probe and ClearScan. RESULTS: In UBM of two healthy subjects, the echogenicity of the lacrimal gland was lower than that of the sclera and homogeneous. But the parenchyma of a patient with Sjögren dry eye syndrome was quite inhomogeneous compared to the healthy subjects. In two patients with dry eye syndrome, we were able to observe some lobules in the parenchyma. We could find excretory ducts running parallel at the surface of the longitudinal section in some subjects. In the longitudinal UBM scan of a subject, we observed a tubular structure at a depth of 1,500 µm that was considered a blood vessel. It ran from the superonasal to the inferotemporal direction. In a subject, we observed a large cyst beneath the conjunctiva. CONCLUSIONS: Lacrimal gland imaging using UBM has both advantages of optical coherence tomography and sonography, and could be useful for evaluating dry eye syndrome.


Assuntos
Aparelho Lacrimal , Microscopia Acústica , Humanos , Microscopia Acústica/métodos , Aparelho Lacrimal/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/diagnóstico por imagem , Idoso , Síndrome de Sjogren/diagnóstico por imagem , Síndrome de Sjogren/diagnóstico
16.
Int Ophthalmol ; 44(1): 204, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671167

RESUMO

BACKGROUND: Dry eye disease (DED) is a common tear film disorder caused by decreased tear production or increased tear evaporation. The increased use of computers in the workplace has brought about the development of ocular health concerns, including dry eye disease. Therefore, this study was designed to determine the prevalence of DED associated with computer work and recommend preventing or reducing its development. This study investigated the prevalence of DED among IT students in Dera Ghazi Khan. METHODS: A cross-sectional descriptive study was conducted among 327 undergraduate students of the IT department in the district of Dera Ghazi khan over 5 months from September 2021 to January 2022. DED was assessed subjectively with Ocular Surface Disease Index. Data were analysed using SPSS version 21. The quantitative analysis was presented as mean and standard deviation, and qualitative variables were introduced in frequency and percentages. The chi-square test (Fisher's exact test) was used to study the significance of associations between dependent and independent variables. RESULTS: The mean age of the participants was 20.25 ± 1.305 years (range 17-25). The prevalence of DED among computer programmers was 47.7%. This study showed that gender (p = 0.31), contact lens usage (p = 0.64), and duration of time spent on computer display units (p = 0.47) were not significant determinants of DED among computer programmers. CONCLUSION: DED is prevalent among IT students, along with different symptoms. However, further studies are required to adequately measure the prevalence of DED during longer exposure time to computer screens and explore environmental risk factors.


Assuntos
Síndromes do Olho Seco , Estudantes , Humanos , Síndromes do Olho Seco/epidemiologia , Síndromes do Olho Seco/diagnóstico , Masculino , Feminino , Prevalência , Estudos Transversais , Adulto Jovem , Adulto , Adolescente , Paquistão/epidemiologia , Estudantes/estatística & dados numéricos , Fatores de Risco , Inquéritos e Questionários , Doenças Profissionais/epidemiologia
17.
Ocul Surf ; 32: 166-172, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38490476

RESUMO

AIM: To assess whether smaller increment and regionalised subjective grading improves the repeatability of corneal fluorescein staining assessment, and to determine the neurological approach adopted for subjective grading by practitioners. METHODS: Experienced eye-care practitioners (n = 28, aged 45 ± 12 years), graded 20 full corneal staining images of patients with mild to severe Sjögren's syndrome with the Oxford grading scheme (both in 0.5 and 1.0 increments, globally and in 5 regions), expanded National Eye Institute (NEI) and SICCA Ocular Staining Score (OSS) grading scales in randomised order. This was repeated after 7-10 days. The digital images were also analysed objectively to determine staining dots, area, intensity and location (using ImageJ) for comparison. RESULTS: The Oxford grading scheme was similar with whole and half unit grading (2.77vs2.81,p = 0.145), but the variability was reduced (0.14vs0.12,p < 0.001). Regional grade was lower (p < 0.001) and more variable (p < 0.001) than global image grading (1.86 ± 0.44 for whole increment grading and 1.90 ± 0.39 for half unit increments). The correlation with global grading was high for both whole (r = 0.928,p < 0.001) and half increment (r = 0.934,p < 0.001) grading. Average grading across participants was associated with particle number and vertical position, with 74.4-80.4% of the linear variance accounted for by the digital image analysis. CONCLUSIONS: Using half unit increments with the Oxford grading scheme improve its sensitivity and repeatability in recording corneal staining. Regional grading doesn't give a comparable score and increased variability. The key neurally extracted features in assigning a subjective staining grade by clinicians were identified as the number of discrete staining locations (particles) and how close to the vertical centre was their spread, across all three scales.


Assuntos
Córnea , Síndromes do Olho Seco , Síndrome de Sjogren , Coloração e Rotulagem , Humanos , Síndrome de Sjogren/diagnóstico , Síndrome de Sjogren/patologia , Síndrome de Sjogren/metabolismo , Pessoa de Meia-Idade , Córnea/patologia , Feminino , Coloração e Rotulagem/métodos , Masculino , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/metabolismo , Corantes Fluorescentes , Fluoresceína , Adulto , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
18.
Eye Contact Lens ; 50(5): 222-232, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38477832

RESUMO

OBJECTIVE: To perform a longitudinal study for determining the development of ocular graft-versus-host disease (oGVHD) after allogeneic hematopoietic stem cell transplant (HSCT) and report cases that illustrate the "window of opportunity" concept in oGVHD treatment. METHODS: Patients (n=61) were examined at prescheduled clinic visits before HSCT and three-month intervals after HSCT for 2 years. The presence or absence of oGVHD was determined using the international chronic oGVHD consensus group diagnostic criteria. Ocular surface washings (OSW) were obtained at each visit and analyzed for cytokine levels. RESULTS: In the longitudinal study, 26.2% (n=16; progressed group) developed either probable (11.5%, n=7) or definite oGVHD (14.8%, n=9). In the progressed group, clinically significant changes in signs (corneal staining and Schirmer I test) and symptoms at the post-HSCT visit as compared with the pre-HSCT visit occurred at 9 months. Significant differences in clinical signs and symptoms (whether average post-HSCT values or changes in values over pre-HSCT levels) between the progressed and nonprogressed groups occurred at a 9-month visit or later. In the progressed group, 55.6% of eyes that had negative matrix metalloproteinase 9 (MMP-9) test at pre-HSCT turned MMP-9 positive at 3 to 6 months post-HSCT. In the progressed group, interleukin 8 levels in OSW were significantly increased at 6 months post-HSCT. In the case reports, the "window of opportunity" was detected by MMP-9 turning positive, early corneal staining, interleukin 8 increase in OSW, and peripheral corneal epithelial thinning, which resolved with treatment initiation. CONCLUSIONS: A "window of opportunity" exists before patients developing symptomatic tear-deficient dry eye after HSCT for initiating treatment that may preempt oGVHD development; however, larger-scale longitudinal studies are needed for definitive recommendations.


Assuntos
Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Humanos , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/terapia , Síndromes do Olho Seco/diagnóstico , Doença Enxerto-Hospedeiro/diagnóstico , Doença Enxerto-Hospedeiro/terapia , Estudos Longitudinais
19.
Med J Malaysia ; 79(Suppl 1): 128-133, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38555897

RESUMO

INTRODUCTION: Breastfeeding women are susceptible to musculoskeletal symptoms and hormonal changes that can affect the ocular surface. As exposure to visual display units (VDU) that is known to cause symptoms of dry eye and computer vision syndrome (CVS) is increasing worldwide, including among breastfeeding women, it is unknown whether this group of VDU users would experience CVS more than non-breastfeeding women. Therefore, this study aimed to investigate the association between breastfeeding status and symptoms of CVS and dry eye. MATERIALS AND METHODS: In this cross-sectional study, selfreported CVS and dry eye symptoms were compared between 80 breastfeeding and 72 non-breastfeeding VDU users. Two questionnaires were administered online, which were the CVS-Questionnaire (CVS-Q) and the Ocular Surface Disease Index (OSDI) questionnaire, to evaluate symptoms of CVS and dry eye, respectively. Mann-Whitney test was used to compare CVS and OSDI scores between groups, while correlations between the scores were analyzed using Spearman's test. RESULT: Results showed that OSDI scores were significantly higher in the non-breastfeeding group (U = 2263, z-score = - 2.276, p = 0.023), indicating more dry eye symptoms experienced by respondents in this group, while no significant group difference was found in terms of CVS scores (U = 2772, z-score = -0.400, p = 0.689). Additionally, no significant association was observed between breastfeeding status and severity of dry eye symptoms as well as CVS symptoms. CONCLUSION: This study reported the possible benefit of breastfeeding in reducing dry eye symptoms. The CVS symptoms found in the breastfeeding group were possibly due to VDU usage rather than caused by breastfeeding. Public education on preventive measures to reduce the occurrence of CVS symptoms and ocular dryness among VDU users is essential to improve the quality of life.


Assuntos
Síndromes do Olho Seco , Qualidade de Vida , Humanos , Feminino , Estudos Transversais , Aleitamento Materno , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/epidemiologia , Síndromes do Olho Seco/etiologia , Inquéritos e Questionários
20.
Int Ophthalmol ; 44(1): 163, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38551693

RESUMO

PURPOSE: To investigate dry eye disease (DED) in newly diagnosed patients with depressive disorder (MDD). METHOD: This observational study included 48 MDD patients in Group 1 and 20 healthy controls in Group 2. Psychiatric and ophthalmic examinations, Beck Depression Inventory (BDI), Ocular Surface Disease Index (OSDI), Schirmer's test, tear breakup time (TBUT), Meibomian gland dysfunction (MGD), and ocular staining were conducted. The results were statistically compared. RESULTS: The participants, comprising 32 men and 36 women, had a mean age of 31.08 ± 11.7 years (18-64 years). Group 1 had a mean BDI score of 30.87 ± 8.56, while Group 2 had a score of 1.3 ± 1.3 (p < 0.001). In Group 1, 28 patients were diagnosed with DED, whereas in Group 2, six subjects were diagnosed with DED. The mean Schirmer's results in Group 1 and Group 2 were (mm/5 min) 10.87 ± 2.44 and 12.70 ± 2.3, respectively, and were significantly lower in Group 1 (p < 0.001). The mean OSDI scores in Group 1 (34.95 ± 15.8) were significantly higher compared to Group 2 (3.2 ± 3.1) (p < 0.001). There was no significant difference in mean TBUT between Group 1 (9.41 ± 2.6 s) and Group 2 (9.8 ± 0.61 s) (p > 0.05). Significant correlations were found between BDI scores and Schirmer's results as well as OSDI scores (p < 0.05, p = 0.02, respectively). No statistically significant correlations were found between BDI scores and TBUT or MGD (p > 0.05). CONCLUSION: DED was found to be more prevalent in the MDD group. The severity of MDD and DED, as indicated by BDI, OSDI, and Schirmer's results, was found to be correlated. It was observed that patients with higher depression scores had more severe dry eye. As a result, we recommend performing ophthalmic examinations in newly diagnosed MDD patients.


Assuntos
Transtorno Depressivo Maior , Síndromes do Olho Seco , Disfunção da Glândula Tarsal , Masculino , Humanos , Feminino , Adulto Jovem , Adulto , Transtorno Depressivo Maior/complicações , Transtorno Depressivo Maior/diagnóstico , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Lágrimas , Índice de Gravidade de Doença