Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Anal Bioanal Chem ; 414(5): 1949-1962, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34981149

RESUMO

Recently, numerous diagnostic approaches from different disciplines have been developed for SARS-CoV-2 diagnosis to monitor and control the COVID-19 pandemic. These include MS-based assays, which provide analytical information on viral proteins. However, their sensitivity is limited, estimated to be 5 × 104 PFU/ml in clinical samples. Here, we present a reliable, specific, and rapid method for the identification of SARS-CoV-2 from nasopharyngeal (NP) specimens, which combines virus capture followed by LC-MS/MS(MRM) analysis of unique peptide markers. The capture of SARS-CoV-2 from the challenging matrix, prior to its tryptic digestion, was accomplished by magnetic beads coated with polyclonal IgG-α-SARS-CoV-2 antibodies, enabling sample concentration while significantly reducing background noise interrupting with LC-MS analysis. A sensitive and specific LC-MS/MS(MRM) analysis method was developed for the identification of selected tryptic peptide markers. The combined assay, which resulted in S/N ratio enhancement, achieved an improved sensitivity of more than 10-fold compared with previously described MS methods. The assay was validated in 29 naive NP specimens, 19 samples were spiked with SARS-CoV-2 and 10 were used as negative controls. Finally, the assay was successfully applied to clinical NP samples (n = 26) pre-determined as either positive or negative by RT-qPCR. This work describes for the first time a combined approach for immuno-magnetic viral isolation coupled with MS analysis. This method is highly reliable, specific, and sensitive; thus, it may potentially serve as a complementary assay to RT-qPCR, the gold standard test. This methodology can be applied to other viruses as well.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Cromatografia Líquida/métodos , Separação Imunomagnética/métodos , SARS-CoV-2/genética , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Anticorpos Antivirais/química , Biomarcadores/química , COVID-19/imunologia , COVID-19/virologia , Teste para COVID-19/instrumentação , Teste para COVID-19/normas , Cromatografia Líquida/instrumentação , Cromatografia Líquida/normas , Humanos , Separação Imunomagnética/instrumentação , Separação Imunomagnética/normas , Nasofaringe/virologia , Peptídeos/química , Peptídeos/imunologia , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/normas
2.
Bull Cancer ; 107(12S): S185-S192, 2020 Dec.
Artigo em Francês | MEDLINE | ID: mdl-33039133

RESUMO

CD34+ immunomagnetic positive selection allows for CD34+ hematopoietic progenitors separation from CD3+ lymphocytes subsets, usually from an apheresis product collected from a previously mobilized donor. This T-cell depleted stem cell graft is primarily intended for rare cases (around 2% of allotransplanted patients in France) of severe, persistent, symptomatic bi- or tri-cytopenia post-allotransplantation, in order to allow for hematologic reconstitution without increasing the risk of GvHD occurrence. Although semi-manual and complex, the process is of sufficient robustness to consistently generate a cellular product with distinctive features and specifications, based on iterative in-process quality controls, that are discussed within these guidelines.


Assuntos
Antígenos CD34 , Células-Tronco Hematopoéticas/citologia , Separação Imunomagnética/métodos , Separação Imunomagnética/normas , Controle de Qualidade , Citaferese , Doença Enxerto-Hospedeiro/prevenção & controle , Células-Tronco Hematopoéticas/imunologia , Humanos , Pancitopenia/terapia , Sociedades Médicas
3.
BMC Res Notes ; 13(1): 211, 2020 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-32276656

RESUMO

OBJECTIVE: Little has been reported regarding the reliability of methods for the purification of human blood eosinophils. We retrospectively reviewed our experience with 350 consecutive eosinophil isolations. RESULTS: Between January 2014 and December 2018, we conducted 350 eosinophil purifications from 83 donors. Absolute eosinophil count (AEC), calculated from hospital complete blood counts when available (n = 289), ranged from 32 to 1352 eosinophils/µL ([Formula: see text]: 179 ± 136/µL). Eosinophil yields ranged from 0.4 to 24.4 million cells per 20 mL of blood drawn ([Formula: see text]: 3.1 ± 1.9 million eosinophils) with > 98% purity. Comparing AEC to actual yield, recovery was 87% ± 29% ([Formula: see text]) and AEC strongly correlated with yield. To explore the reproducibility of yield, a subsequent analysis was limited to those donors drawn ≥ 3 times (N = 35), and there was no difference in the average coefficient of variation for yield between allergic and non-allergic donors. Viability of isolated eosinophils was consistently > 95% and after 24 h of culture did not differ between allergic and non-allergic donors. We conclude that this immunomagnetic separation method for human eosinophil isolation from whole blood is a reliable, reproducible technique for obtaining an average of 87% yield with high purity and viability.


Assuntos
Centrifugação com Gradiente de Concentração , Eosinófilos , Separação Imunomagnética , Adulto , Centrifugação com Gradiente de Concentração/normas , Feminino , Humanos , Separação Imunomagnética/normas , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
4.
J Leukoc Biol ; 107(6): 1097-1105, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31967358

RESUMO

Dissection of the role and function of human γδ T cells and their heterogeneous subsets in cancer, inflammation, and auto-immune diseases is a growing and dynamic research field of increasing interest to the scientific community. Therefore, harmonization and standardization of techniques for the characterization of peripheral and tissue-resident γδ T cells is crucial to facilitate comparability between published and emerging research. The application of commercially available reagents to classify γδ T cells, in particular the combination of multiple Abs, is not always trouble-free, posing major demands on researchers entering this field. Occasionally, even entire γδ T cell subsets may remain undetected when certain Abs are combined in flow cytometric analysis with multicolor Ab panels, or might be lost during cell isolation procedures. Here, based on the recent literature and our own experience, we provide an overview of methods commonly employed for the phenotypic and functional characterization of human γδ T cells including advanced polychromatic flow cytometry, mass cytometry, immunohistochemistry, and magnetic cell isolation. We highlight potential pitfalls and discuss how to circumvent these obstacles.


Assuntos
Citometria de Fluxo/normas , Separação Imunomagnética/normas , Receptores de Antígenos de Linfócitos T gama-delta/análise , Subpopulações de Linfócitos T/imunologia , Anticorpos/química , Carcinoma/diagnóstico , Carcinoma/imunologia , Carcinoma/patologia , Estudos de Casos e Controles , Neoplasias do Colo/diagnóstico , Neoplasias do Colo/imunologia , Neoplasias do Colo/patologia , Citometria de Fluxo/métodos , Corantes Fluorescentes/química , Expressão Gênica , Doença de Hodgkin/diagnóstico , Doença de Hodgkin/imunologia , Doença de Hodgkin/patologia , Humanos , Imuno-Histoquímica , Separação Imunomagnética/métodos , Leucócitos Mononucleares/imunologia , Leucócitos Mononucleares/patologia , Receptores de Antígenos de Linfócitos T gama-delta/genética , Receptores de Antígenos de Linfócitos T gama-delta/imunologia , Subpopulações de Linfócitos T/patologia
6.
J Immunol Methods ; 470: 15-19, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31004578

RESUMO

Neutrophil gelatinase-associated lipocalin (NGAL) is a promising biomarker for diagnosing acute kidney injury (AKI). Currently, there are few assays for determining NGAL and they are complex, time-consuming or expensive. We aimed to establish an efficient immunoassay to measure NGAL in human urine simply and rapidly. A novel immunoassay for NGAL determination was established by combining a dissociation-enhanced-free time-resolved fluoroimmunoassay (TRFIA) and immunomagnetic separation. Based on a "sandwich"-type immunoassay format, analytes in samples were captured by a pair of monoclonal antibodies (mAb) in which one mAb was coated in magnetic beads and the other mAb was labeled with europium(III) chelate microparticles (CM-EUs) as "fluorescent reporters". NGAL concentrations were determined in a linear range (10-1500 ng mL-1) with a limit of detection of 0.32 ng mL-1. The reproducibility, recovery, and specificity of our TRFIA were acceptable. Our method was compared with that of a chemiluminescence immunoassay (CMIA) using 115 urine samples, and the results showed good correlation (R2 = 0.8677). We expect our novel method to be useful for the early diagnosis of AKI.


Assuntos
Injúria Renal Aguda/diagnóstico , Fluorimunoensaio/métodos , Imunoconjugados/química , Separação Imunomagnética/métodos , Lipocalina-2/urina , Injúria Renal Aguda/fisiopatologia , Injúria Renal Aguda/urina , Anticorpos Monoclonais/química , Biomarcadores/urina , Diagnóstico Precoce , Fluorimunoensaio/normas , Humanos , Separação Imunomagnética/normas , Limite de Detecção , Imãs/química , Compostos Organometálicos/química , Reprodutibilidade dos Testes
7.
Methods Mol Biol ; 1829: 205-212, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29987724

RESUMO

Plastids are key organelles in both photosynthetic and nonphotosynthetic organisms. In photosynthetic organisms, plastids can be readily purified using differential centrifugations due to the high density of photosynthetic membranes or thylakoids. The apicomplexan plastid (the apicoplast) is an essential nonphotosynthetic plastid that lacks thylakoid and was not readily purified using conventional methods. Here, we describe a tractable method to purify intact apicoplasts from Plasmodium falciparum blood stages using magnetic beads and affinity purification.


Assuntos
Apicoplastos , Fracionamento Celular/métodos , Separação Imunomagnética , Plasmodium falciparum , Fracionamento Celular/normas , Linhagem Celular , Separação Imunomagnética/métodos , Separação Imunomagnética/normas
8.
J Proteome Res ; 15(10): 3473-3480, 2016 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-27570895

RESUMO

Enhanced by the growing number of biobanks, biomarker studies can now be performed with reasonable statistical power by using large sets of samples. Antibody-based proteomics by means of suspension bead arrays offers one attractive approach to analyze serum, plasma, or CSF samples for such studies in microtiter plates. To expand measurements beyond single batches, with either 96 or 384 samples per plate, suitable normalization methods are required to minimize the variation between plates. Here we propose two normalization approaches utilizing MA coordinates. The multidimensional MA (multi-MA) and MA-loess both consider all samples of a microtiter plate per suspension bead array assay and thus do not require any external reference samples. We demonstrate the performance of the two MA normalization methods with data obtained from the analysis of 384 samples including both serum and plasma. Samples were randomized across 96-well sample plates, processed, and analyzed in assay plates, respectively. Using principal component analysis (PCA), we could show that plate-wise clusters found in the first two components were eliminated by multi-MA normalization as compared with other normalization methods. Furthermore, we studied the correlation profiles between random pairs of antibodies and found that both MA normalization methods substantially reduced the inflated correlation introduced by plate effects. Normalization approaches using multi-MA and MA-loess minimized batch effects arising from the analysis of several assay plates with antibody suspension bead arrays. In a simulated biomarker study, multi-MA restored associations lost due to plate effects. Our normalization approaches, which are available as R package MDimNormn, could also be useful in studies using other types of high-throughput assay data.


Assuntos
Separação Imunomagnética/normas , Análise de Componente Principal/métodos , Proteômica/métodos , Anticorpos , Biomarcadores/análise , Simulação por Computador , Humanos , Separação Imunomagnética/estatística & dados numéricos , Análise em Microsséries/normas , Análise em Microsséries/estatística & dados numéricos , Padrões de Referência
9.
Clin Cancer Res ; 21(17): 3957-68, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-25991821

RESUMO

PURPOSE: Engineering T cells with receptors to redirect the immune system against cancer has most recently been described as a scientific breakthrough. However, a main challenge remains the GMP-grade purification of immune cells selectively expressing the introduced receptor in order to reduce potential side effects due to poorly or nonengineered cells. EXPERIMENTAL DESIGN: In order to test a novel purification strategy, we took advantage of a model γδT cell receptor (TCR), naturally interfering with endogenous TCR expression and designed the optimal retroviral expression cassette to achieve maximal interference with endogenous TCR chains. Following retroviral transduction, nonengineered and poorly engineered immune cells characterized by a high endogenous αßTCR expression were efficiently depleted with GMP-grade anti-αßTCR beads. Next, the engineered immune cells were validated for TCR expression, function against a panel of tumor cell lines and primary tumors and potential allo-reactivity. Engineered immune cells were further validated in two humanized mouse tumor models. RESULTS: The untouched enrichment of engineered immune cells translated into highly purified receptor-engineered cells with strong antitumor reactivity both in vitro and in vivo. Importantly, this approach eliminated residual allo-reactivity of engineered immune cells. Our data demonstrate that even with long-term suboptimal interference with endogenous TCR chains such as in resting cells, allo-reactivity remained absent and tumor control preserved. CONCLUSIONS: We present a novel enrichment method for the production of untouched engineered immune cells, ready to be translated into a GMP-grade method and potentially applicable to all receptor-modified cells even if interference with endogenous TCR chains is far from complete.


Assuntos
Engenharia Genética , Imunoterapia , Neoplasias/genética , Neoplasias/imunologia , Animais , Linhagem Celular , Terapia Baseada em Transplante de Células e Tecidos/métodos , Terapia Baseada em Transplante de Células e Tecidos/normas , Modelos Animais de Doenças , Feminino , Expressão Gênica , Vetores Genéticos/genética , Humanos , Separação Imunomagnética/métodos , Separação Imunomagnética/normas , Imunoterapia/métodos , Imunoterapia/normas , Depleção Linfocítica/métodos , Camundongos , Camundongos Knockout , Neoplasias/patologia , Neoplasias/terapia , Receptores de Antígenos de Linfócitos T/genética , Receptores de Antígenos de Linfócitos T gama-delta/genética , Retroviridae/genética , Subpopulações de Linfócitos T/imunologia , Subpopulações de Linfócitos T/metabolismo , Transdução Genética , Transgenes
10.
Clin Neuropathol ; 33(5): 329-34, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25131945

RESUMO

With the aim to evaluate the significance and reliability of detecting disease-specific α-synuclein in the cerebrospinal fluid (CSF) we developed an ELISA and bead-assay. We used a commercial antibody (5G4) that does not bind to the physiological monomeric form of α-synuclein, but is highly specific for the disease-associated forms, including high molecular weight fraction of ß-sheet rich oligomers. We applied both tests in CSF from a series of neuropathologically confirmed α-synucleinopathy cases, including Parkinson' disease dementia (PDD) and dementia with Lewy bodies (DLB) (n = 7), as well as Alzheimer' disease (n = 6), and control patients without neurodegenerative pathologies (n = 9). Disease-specific α-synuclein was detectable in the CSF in a subset of patients with α-synuclein pathology in the brain. When combined with the analysis of total α-synuclein, the bead-assay for disease-specific α-synuclein was highly specific for PDD/DLB. Detection of disease-associated αsynuclein combined with the total levels of α-synuclein is a promising tool for the in-vivo diagnosis of α-synucleinopathies, including PDD and LBD.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Separação Imunomagnética/métodos , Doenças Neurodegenerativas/líquido cefalorraquidiano , Doenças Neurodegenerativas/diagnóstico , alfa-Sinucleína/líquido cefalorraquidiano , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/líquido cefalorraquidiano , Doença de Alzheimer/diagnóstico , Ensaio de Imunoadsorção Enzimática/normas , Estudos de Viabilidade , Feminino , Humanos , Separação Imunomagnética/normas , Doença por Corpos de Lewy/líquido cefalorraquidiano , Doença por Corpos de Lewy/diagnóstico , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/líquido cefalorraquidiano , Doença de Parkinson/diagnóstico , Reprodutibilidade dos Testes
11.
Int J Food Microbiol ; 179: 33-7, 2014 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-24718031

RESUMO

Escherichia coli O157:H7 is a major cause of foodborne illness and methods for rapid and sensitive detection of this deadly pathogen are needed to protect consumers. The use of immunomagnetic separation (IMS) for capturing and detecting foodborne pathogens has gained popularity, partially due to the introduction of automated and high throughput IMS instrumentation. Three methods for automated IMS that test different sample volumes, Kingfisher mL, Pathatrix Auto, and Pathatrix Ultra, were compared using microbiological detection of E. coli O157:H7 from buffered peptone water (BPW), in the presence of background microbial flora derived from spinach leaves, and from culture enrichments from artificially contaminated spinach leaves. The average efficiencies of capture of E. coli O157:H7 using the three methods were 32.1%, 3.7%, and 1.3%, respectively, in BPW; 43.4%, 8.8%, 2.9%, respectively, in the presence of spinach microbial flora; and 63.0%, 7.0%, and 6.3%, respectively, from artificially contaminated spinach. Despite the large differences in IMS capture efficiencies between the KingFisher and two Pathatrix methods, all three methods allowed the detection of E. coli O157:H7 from spinach that was artificially contaminated with the pathogen at relatively high (25 cfu/30 g sample) and low (1 cfu/30 g sample) levels after 4-6h of culture enrichment. The differences in capture efficiency were compensated for by the differences in sample volume used by the KingFisher mL (1 mL), Pathatrix Auto (50 mL) and Pathatrix Ultra (250 mL) instruments. Thus, despite the reduced capture efficiencies observed for the Pathatrix methods, the large increase in sample volume results in a greater number of captured cells for downstream detection resulting in improved detection sensitivity.


Assuntos
Escherichia coli O157/isolamento & purificação , Microbiologia de Alimentos/métodos , Separação Imunomagnética/normas , Spinacia oleracea/microbiologia , Escherichia coli O157/fisiologia , Sensibilidade e Especificidade
12.
J Food Prot ; 77(1): 100-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24406005

RESUMO

Escherichia coli O157:H7 is a major foodborne pathogen that has posed serious problems for food safety and public health. Recent outbreaks and recalls associated with various foods contaminated by E. coli O157:H7 clearly indicate its deleterious effect on food safety. A rapid and sensitive detection assay is needed for this harmful organism to prevent foodborne illnesses and control outbreaks in a timely manner. We developed a magnetic bead-based immunoassay for detection of E. coli O157:H7 (the most well-known Shiga toxigenic E. coli strain) with a 96-well microplate as an assay platform. Immunomagnetic separation (IMS) and tyramide signal amplification were coupled to the assay to increase its sensitivity and specificity. This immunoassay was able to detect E. coli O157:H7 in pure culture with a detection limit of 50 CFU/ml in less than 3 h without an enrichment step. The detection limit was decreased 10-fold to 5 CFU/ml with addition of a 3-h enrichment step. When this assay was tested with other nontarget foodborne pathogens and common enteric bacteria, no cross-reactivity was found. When tested with artificially contaminated ground beef and milk samples, the assay sensitivity decreased two- to fivefold, with detection limits of 250 and 100 CFU/ml, respectively, probably because of the food matrix effect. The assay results also were compared with those of a sandwich-type enzyme-linked immunosorbent assay (ELISA) and an ELISA coupled with IMS; the developed assay was 25 times and 4 times more sensitive than the standard ELISA and the IMS-ELISA, respectively. Tyramide signal amplification combined with IMS can improve sensitivity and specificity for detection of E. coli O157:H7. The developed assay could be easily adapted for other foodborne pathogens and will contribute to improved food safety and public health.


Assuntos
Escherichia coli O157/isolamento & purificação , Separação Imunomagnética/métodos , Separação Imunomagnética/normas , Produtos da Carne/microbiologia , Leite/microbiologia , Tiramina/química , Animais , Bovinos , Contagem de Colônia Microbiana/métodos , Qualidade de Produtos para o Consumidor , Ensaio de Imunoadsorção Enzimática , Escherichia coli O157/imunologia , Corantes Fluorescentes/química , Contaminação de Alimentos/análise , Microbiologia de Alimentos , Doenças Transmitidas por Alimentos , Humanos , Imunoensaio/métodos , Sensibilidade e Especificidade
13.
Mol Vis ; 18: 2922-30, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23233794

RESUMO

PURPOSE: To establish an effective system for isolating primary retinal ganglion cells (RGCs) from newborn mice. METHODS: The retinas were separated from enucleated eyeballs of Crl:CD-1 mice on postnatal day 1 to 4. RGCs were purified using three different methods, including two-step immunopanning (TSI), direct magnetic separation (DMS), and immunopanning-magnetic separation (IMS). Harvested cells were maintained for 24 h in a defined medium and then examined with immunocytochemistry, western immunoblotting, and real-time reverse transcription polymerase chain reaction (RT-PCR) for glial cell-specific glial fibrillary acidic protein (GFAP) and amacrine cell-specific syntaxin 1. RESULTS: As determined with immunofluorescence staining, RGCs purified by TSI were sparsely mixed with GFAP-positive astrocytes, and RGCs isolated by DMS were frequently mixed with syntaxin 1-positive amacrine cells. However, RGCs collected by IMS were seldom contaminated by GFAP-positive or syntaxin 1-positive cells. On western immunoblots, TSI cells showed significant GFAP expression, and DMS cells showed apparent syntaxin 1 expression, but IMS cells did not. Results of the real-time RT-PCR showed a similar tendency to those of the immunocytochemistry and western immunoblots. CONCLUSION: Primary mouse RGCs were highly purified by the IMS method, combining the benefits of the TSI and DMS methods. This isolation method may provide a good experimental system for studying glaucoma in vitro.


Assuntos
Separação Imunomagnética/métodos , Células Ganglionares da Retina/citologia , Células Amácrinas/citologia , Células Amácrinas/metabolismo , Animais , Animais Recém-Nascidos , Anticorpos/química , Anticorpos/imunologia , Astrócitos/citologia , Astrócitos/metabolismo , Biomarcadores/metabolismo , Western Blotting , Feminino , Expressão Gênica , Proteína Glial Fibrilar Ácida , Imuno-Histoquímica , Separação Imunomagnética/normas , Camundongos , Proteínas do Tecido Nervoso/genética , Proteínas do Tecido Nervoso/metabolismo , Cultura Primária de Células , Reação em Cadeia da Polimerase em Tempo Real , Células Ganglionares da Retina/metabolismo , Sintaxina 1/genética , Sintaxina 1/metabolismo
14.
J Transl Med ; 10: 192, 2012 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-22978632

RESUMO

BACKGROUND: Circulating melanoma cells (CMCs) are thought to be valuable in improving measures of prognosis in melanoma patients and may be a useful marker of residual disease to identify non-metastatic patients requiring adjuvant therapy. We investigated whether immunomagnetic enrichment targeting multiple markers allows more efficient enrichment of CMCs from patient peripheral blood than targeting a single marker. Furthermore, we aimed to determine whether the number of CMCs in patient blood was associated with disease stage. METHODS: We captured CMCs by targeting the melanoma associated markers MCSP and MCAM as well as the melanoma stem cell markers ABCB5 and CD271, both individually and in combination, by immunomagnetic enrichment. CMCs were enriched and quantified from the peripheral blood of 10 non-metastatic and 13 metastatic melanoma patients. RESULTS: Targeting all markers in combination resulted in the enrichment of more CMCs than when any individual marker was targeted (p < 0.001-0.028). Furthermore, when a combination of markers was targeted, a greater number of CMCs were enriched in metastatic patients compared with non-metastatic patients (p = 0.007). CONCLUSIONS: Our results demonstrated that a combination of markers should be targeted for optimal isolation of CMCs. In addition, there are significantly more CMCs in metastatic patients compared with non-metastatic patients and therefore quantification of CMCs may prove to be a useful marker of disease progression.


Assuntos
Separação Imunomagnética/normas , Melanoma/sangue , Células Neoplásicas Circulantes , Imunofluorescência , Humanos , Melanoma/patologia , Metástase Neoplásica
15.
Anal Biochem ; 421(1): 219-26, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-22178913

RESUMO

Mitochondrial preparation is a key technique in the study of mitochondria. Growing evidence has demonstrated that mitochondrial proteins are tissue or cell type dependent. Locating the proteins in the global presence of mitochondrial membranes is a primary consideration in adopting antibodies for affinity enrichment of mitochondria on a micro scale. Two proteins located on the outer membrane of mitochondria, cytochrome b5 type B (CYB5B) and synaptojanin-2-binding protein (SYNJ2BP), were selected as candidates based on a survey of databases and the literature. The polyclonal antibodies against the truncated CYB5B and SYNJ2BP exhibited specific recognition to mitochondria and wider sensitivity to several tested mouse tissues and cell lines, whereas the antibody 22-kDa translocase of the outer mitochondrial membrane (TOM22) nearly missed detection of mitochondria in the liver and responded minimally to mitochondria from H9C2 and L-02 cells. Through the affinity enrichment for cellular mitochondria using magnetic beads coated with anti-CYB5B or anti-SYNJ2BP, we found that the anti-CYB5B beads could enrich mitochondria more efficiently even on a scale of 10,000 cultured cells. For the integrity and protein components, the enriched mitochondria on anti-CYB5B were carefully examined and were accepted in further functional study. We propose that an anti-CYB5B immunomagnetic approach is feasible in the micropreparation of mitochondria from cultured cells.


Assuntos
Fracionamento Celular/métodos , Separação Imunomagnética/métodos , Mitocôndrias/química , Mitocôndrias/imunologia , Proteínas Adaptadoras de Transdução de Sinal/genética , Proteínas Adaptadoras de Transdução de Sinal/imunologia , Animais , Afinidade de Anticorpos , Sequência de Bases , Fracionamento Celular/normas , Linhagem Celular , Citocromos b5/genética , Citocromos b5/imunologia , Primers do DNA/genética , Separação Imunomagnética/normas , Proteínas de Membrana/genética , Proteínas de Membrana/imunologia , Camundongos , Fragmentos de Peptídeos/genética , Fragmentos de Peptídeos/imunologia , Proteômica/métodos , Controle de Qualidade , Proteínas Recombinantes/genética , Proteínas Recombinantes/imunologia
17.
Int J Hematol ; 92(2): 314-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20694533

RESUMO

Plasma cells (PCs) enrichment from bone marrow samples of multiple myeloma (MM) patients is frequently performed by immunomagnetic separation (magnetic activated cell sorting, MACS) using anti-CD138 MicroBeads. The aim of our work was to find optimal strategy for immunomagnetic separation of PCs and determine optimal algorithm of separation techniques for samples with various percentage of neoplastic cells. From 2007 to 2008, selection of PCs using separation programs Possels and Posseld(2) was carried out on 234 bone marrow samples obtained from 208 MM patients. In 2008, an optimal algorithm for separation programs was introduced based on the analysis of the previous experiments. The Possels program is applicable for samples with >10% PCs in the mononuclear fraction, while the Posseld(2) program is used for samples with 5-10% PCs in the mononuclear fraction. Median purity of 92.6% for the positive fraction of cells (range 14.5-99.6%) and median recovery of 60.4% (range 25.7-99.5%) were obtained when the Possels program was applied (n = 45). A total of 80% (36/45) of processed samples had purity of >70%. Median purity for the positive fraction of 83.7% (range 14.3-99.7%) and median recovery of 14.3% (range 3.6-50.0%) were achieved using the Posseld(2) program (n = 99). A total of 68% (67/99) of processed samples reached >70% purity. This separation strategy enabled us to obtain sufficient amounts of highly purified PCs required for subsequent research purposes. The MACS method has been unsuccessful if the percentage of PCs in the initial sample was <5%. These samples were processed by fluorescence activated cell sorting (FACS).


Assuntos
Medula Óssea/patologia , Separação Imunomagnética/métodos , Separação Imunomagnética/normas , Mieloma Múltiplo/patologia , Algoritmos , Humanos , Métodos , Software/normas
18.
Transfusion ; 50(12): 2643-8, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20576014

RESUMO

BACKGROUND: Granulocyte antibodies have been implicated in allo- and autoimmune neutropenia and in transfusion reactions. STUDY DESIGN AND METHODS: Fifty-one sera from suspected alloimmune neutropenia or transfusion-related acute lung injury (TRALI) and 40 sera from suspected autoimmune neutropenia were tested for granulocyte antibodies using LABScreen MULTI (One Lambda, Inc.), compared with classical tests (flow cytometry [FC] and granulocyte agglutination [GAT] followed by monoclonal antibody-specific immobilization of granulocyte antigens [MAIGA]). RESULTS: In alloimmune situations, 48 sera were concordant (94%), two sera positive for HNA with LABScreen MULTI were negative by FC/GAT and/or MAIGA, and one serum sample negative for HNA with LABScreen MULTI was positive by classical tests. In autoimmune neutropenia, 30 sera were concordant (75%), four sera positive for HNA with LABScreen MULTI were negative by FC/GAT and/or MAIGA, and six sera negative for HNA with LABScreen MULTI were positive by FC/GAT and/or MAIGA. For detection of autoantibodies, the LABScreen MULTI was less concordant. However, with the exception of one case, the discrepancies were observed in sera that did not show a clear specificity. CONCLUSIONS: LABScreen MULTI correlated well with our classical methods for HNA-1 and HNA-2a antibody screening. It can be used for screening blood donors or patients suspected of TRALI, but GAT is still needed for HNA-3a antibody screening.


Assuntos
Anticorpos/análise , Granulócitos/imunologia , Separação Imunomagnética/métodos , Programas de Rastreamento/métodos , Lesão Pulmonar Aguda/sangue , Lesão Pulmonar Aguda/etiologia , Lesão Pulmonar Aguda/imunologia , Anticorpos/sangue , Anticorpos/imunologia , Autoanticorpos/análise , Autoanticorpos/imunologia , Humanos , Imunoensaio/métodos , Imunoensaio/normas , Separação Imunomagnética/normas , Recém-Nascido , Isoantígenos/análise , Isoantígenos/imunologia , Programas de Rastreamento/normas , Neutropenia/sangue , Neutropenia/congênito , Neutropenia/imunologia , Valores de Referência , Testes Sorológicos/métodos , Testes Sorológicos/normas , Trombocitopenia Neonatal Aloimune/sangue , Trombocitopenia Neonatal Aloimune/imunologia , Reação Transfusional
19.
Int J Urol ; 17(3): 254-8, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20148989

RESUMO

OBJECTIVES: To evaluate the relationship between circulating tumor cells (CTC) and clinical parameters in metastatic urothelial cancer (UC). METHODS: CTC were enumerated with the CellSearch System, which was developed using an EpCAM antibody-based immunomagnetic capture and automated staining methodology. UC cell lines (RT4, T24, TCC, UMUC3 and 253J) and mixed blood from healthy males were analyzed. Blood samples from 16 patients without metastatic UC and 20 patients with metastatic UC were also analyzed. RESULTS: The accuracy and reliability of the assay were determined using spiked UC cells (RT4 and T24), which showed a strong linear correlation (r = 0.99) and recovery rate of 94% +/- 5% and 84% +/- 6%, respectively. Three UC cell lines (TCC, UMUC3 and 253J) tested negative. The 16 patients without metastatic UC tested negative as well. Eleven (55%) patients with metastatic UC tested positive for at least one CTC. Seven (35%) had two or more CTC. Significantly more CTC were seen in patients with two or more sites of metastasis than those with one site of metastasis (P = 0.004). CONCLUSIONS: Based on these findings, CTC could represent a potential marker to monitor the response to chemotherapy in patients with metastatic UC.


Assuntos
Separação Imunomagnética/métodos , Neoplasias Pulmonares/secundário , Células Neoplásicas Circulantes/patologia , Neoplasias Ureterais/patologia , Neoplasias da Bexiga Urinária/patologia , Urotélio/patologia , Idoso , Neoplasias Ósseas/secundário , Feminino , Humanos , Separação Imunomagnética/normas , Neoplasias Hepáticas/secundário , Metástase Linfática , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Biosens Bioelectron ; 25(7): 1755-60, 2010 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-20097055

RESUMO

An electrochemical immunosensor involving magnetic beads and disposable carbon screen-printed electrodes (SPEs) for zearalenone (Zea) sensing has been developed and evaluated using a certified reference material (CRM) and selected baby food samples. After the immunochemical reaction, the modified paramagnetic beads were confined by a magnet on surface of SPE platforms where electrochemical detection is simply achieved through the suitable substrate and mediator for the HRP enzyme. A remarkable detection limit of 0.007 microg L(-1) and excellent accuracy with recovery rate of 101-111% showed the proposed system to be a very suitable screening tool for the analysis of zearalenone in baby food samples. A new simple, fast and reliable strategy involving the sequential performing of calibration and analysis of target mycotoxin using just one disposable SPE each is additionally proposed. Excellent analytical performance in terms of accuracy and precision were again obtained with a remarkable low systematic error (less than 4%) and excellent reproducibility (RSD=6%). This strategy enhanced the analytical merits of immunosensor approach towards truly analytical disposable tools for food-safety scene.


Assuntos
Técnicas Biossensoriais/instrumentação , Condutometria/instrumentação , Equipamentos Descartáveis , Análise de Alimentos/instrumentação , Contaminação de Alimentos/análise , Separação Imunomagnética/instrumentação , Zearalenona/análise , Técnicas Biossensoriais/métodos , Calibragem , Condutometria/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Alimentos/normas , Separação Imunomagnética/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espanha , Zearalenona/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...