Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.213
Filtrar
1.
Arch Esp Urol ; 77(5): 479-490, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38982776

RESUMO

OBJECTIVE: Meta-analysis was conducted to compare and evaluate the efficacy and safety of tension-free vaginal tape (TVT), outside-in trans-obturator tape (TOT), inside-out tension-free vaginal tape-obturator (TVT-O) and transvaginal tension-free urethral sling surgery (TVT-S) in the treatment of female stress urinary incontinence (SUI). METHODS: A computer-based systematic search of the PubMed, The Cochrane Library, Medline, Embase, Web of Science and ScienceDirect databases for randomised controlled trials (RCTs) comparing TVT, TOT, TVT-O and TVT-S for the treatment of SUI was performed from the time of library construction to November 2023. Two investigators performed data extraction and quality evaluation of the included RCTs, extracting information including the follows: First author, time of publication, intervention, sample size, age, duration of follow-up and objective cure rate, subjective cure rate, dyspareunia, vaginal mucosal perforation, urinary tract infection, sling exposure and postoperative thigh pain/groin pain. Review Manager (RevMan) 5.4 was used for data processing. RESULTS: A total of 14 RCTs with 2665 patients were included. Meta-analysis showed no statistically significant differences in objective cure rate, urinary tract infection, sling exposure and postoperative thigh pain/groin pain. The subjective cure rate of TVT was higher than that of TOT (odds ratio (OR), 95% confidence interval (CI) = 1.37 (1.02, 1.84), p = 0.03); The incidence of TVT-O voiding difficulty was lower than that of TVT (OR, 95% CI = 2.94 (1.20, 7.20), p = 0.02); And the incidence of vaginal mucosal perforation of TOT was lower than that of TVT (OR, 95% CI = 0.11 (0.02, 0.61), p = 0.01). CONCLUSIONS: The four surgical procedures, TVT, TOT, TVT-O and TVT-S, were relatively similar in terms of SUI outcomes. TVT had a higher subjective cure rate than TOT and a higher incidence of postoperative dyspareunia and vaginal mucosal perforation.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Procedimentos Cirúrgicos Urológicos , Feminino , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Slings Suburetrais/efeitos adversos , Resultado do Tratamento , Incontinência Urinária por Estresse/cirurgia , Procedimentos Cirúrgicos Urológicos/métodos , Procedimentos Cirúrgicos Urológicos/efeitos adversos
2.
Int Urogynecol J ; 35(6): 1327-1329, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38733381

RESUMO

INTRODUCTION AND HYPOTHESIS: This video illustrates a rare surgical case involving a urethral diverticulum, urethrovaginal fistula, and mesh erosion. METHODS: We present a 58-year-old patient attending a tertiary care center with a suspected urethrovaginal fistula. Her concerns included stress urinary incontinence (SUI), recurrent urinary tract infection, and vaginal pain. The surgical history was notable for the placement of two different mesh slings during the same procedure to treat SUI. Preoperative evaluation and findings are illustrated in detail. The video uses a high-definition surgical camera to emphasize the initial intraoperative evaluation with localization of the fistula and diverticulum. We then demonstrate the approach to the dissection with the goal of ensuring complete resection of the diverticulum, fistula, and mesh, while preserving healthy tissue for subsequent closure. The utilization of unique and specialized tools for each portion of the procedure is also illustrated. A layered vaginal closure, including a Martius flap, is created to prevent recurrence. RESULTS: The surgery was accomplished without complications. CONCLUSIONS: To our knowledge, concomitant findings of a urethral diverticulum, urethrovaginal fistula, and mesh erosion are unique in the literature. We postulate that this triad could have resulted from the mesh burden in this particular patient.


Assuntos
Divertículo , Telas Cirúrgicas , Doenças Uretrais , Fístula Urinária , Fístula Vaginal , Humanos , Feminino , Pessoa de Meia-Idade , Divertículo/cirurgia , Fístula Vaginal/cirurgia , Fístula Vaginal/etiologia , Doenças Uretrais/cirurgia , Doenças Uretrais/etiologia , Telas Cirúrgicas/efeitos adversos , Fístula Urinária/cirurgia , Fístula Urinária/etiologia , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Slings Suburetrais/efeitos adversos
3.
Int Urogynecol J ; 35(6): 1177-1182, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38703222

RESUMO

INTRODUCTION AND HYPOTHESIS: The objective was to investigate the relationship between mesh exposure and persistent stress urinary incontinence (SUI) post-midurethral sling (MUS) surgery. METHODS: Extensive data collection including patient demographics, obstetric history, existing medical conditions, previous surgeries, and surgical outcomes, encompassing both perioperative and postoperative complications. RESULTS: Out of 456 patients who underwent the MUS procedure within the specified period, the persistence of SUI was noted in 6.4% of cases. Mesh exposure was observed in 8.8% of these cases. Notably, 25% of patients with mesh exposure suffered from persistent SUI, in stark contrast to 4.6% of those without mesh exposure (p < 0.0001). Further, multivariate analysis indicated that patients with mesh exposure had an approximately 6.5-fold increased likelihood (95% CI: 2.71-15.44) of experiencing persistent SUI compared with those without mesh exposure. CONCLUSIONS: Mesh exposure is a significant independent risk factor for persistent SUI post-MUS surgery. Patients with mesh exposure are about 6.5 times more prone to persistent SUI than those without. Although mesh exposure is typically managed with expectant measures, vaginal estrogen or mesh excision, current evidence does not support surgical revision of MUS affected by mesh exposure or additional incontinence procedures during mesh excision.


Assuntos
Slings Suburetrais , Telas Cirúrgicas , Incontinência Urinária por Estresse , Humanos , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Feminino , Pessoa de Meia-Idade , Slings Suburetrais/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Fatores de Risco , Idoso , Adulto , Estudos Retrospectivos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia
4.
Arch Gynecol Obstet ; 309(6): 2937-2941, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38743075

RESUMO

PURPOSE: To assess the effectiveness of a long-acting anesthetic injection into the obturator membrane for pain relief in women undergoing trans-obturator tension-free vaginal tape. METHODS: A total of 22 women were randomized for the intra-operative injection of bupivacaine into one of their obturator membranes: the left or right side. All the participants were asked to define their groin pain on a visual analog scale (scored 0-10 cm) at 1, 6, 12, and 24 h post-operative. For each woman, pain scores were compared between the local anesthetic-injected side and the opposite side. RESULTS: Statistically significant differences were not observed in groin pain scores between the bupivacaine injection side and the no injection side at 1 h (p = 0.76), 6 h (p = 1), 12 h (p = 0.95), and 24 h (p = 0.82) post-operative. CONCLUSION: In women who undergo trans-obturator tension-free vaginal tape procedures, intra-operative intra-obturator injection of local anesthetics is not effective in alleviating the characteristic post-operative groin pain. TRIAL REGISTRATION: This study is registered on ClinicalTrials.gov (NCT03479996).


Assuntos
Anestésicos Locais , Bupivacaína , Medição da Dor , Dor Pós-Operatória , Slings Suburetrais , Humanos , Feminino , Bupivacaína/administração & dosagem , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Anestésicos Locais/administração & dosagem , Slings Suburetrais/efeitos adversos , Pessoa de Meia-Idade , Adulto , Virilha , Incontinência Urinária por Estresse/cirurgia , Injeções , Idoso
5.
World J Urol ; 42(1): 125, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38460045

RESUMO

PURPOSE: To review our 10-year experience with laser excision for urethral mesh erosion (UME) of mid-urethral slings (MUS). METHODS: Following Institutional Review Board approval, the charts of female patients with endoscopic laser excision of UME were retrospectively reviewed. Demographics, clinical presentation, surgical history, pre- and post-operative Urinary Distress Inventory-6 scores and quality of life ratings, operative reports, and outcomes were obtained from electronic medical records. UME cure was defined as no residual mesh on office cystourethroscopy 5-6 months after the final laser excision procedure. RESULTS: From 2011 to 2021, 23 patients met study criteria; median age was 56 (range 44-79) years. Twenty (87%) had multiple prior urogynecologic procedures. Median time from MUS placement to presentation with UME-related complaints was 5.3 [interquartile range (IQR) 2.3-7.6] years. The most common presenting symptom was recurrent urinary tract infection (rUTI) (n = 10). Median operating time was 49 (IQR 37-80) minutes. Median duration of follow-up was 24 (IQR 12-84) months. Fourteen (61%) required more than 1 laser excision procedure for UME. Although 5 were asymptomatic (22%), new (n = 5) or persistent (n = 8) urinary incontinence was the most common symptom on follow-up (57%). CONCLUSION: UME presenting symptoms are highly variable, necessitating a high index of suspicion in patients with a history of MUS, especially in the case of rUTI. Endoscopic laser excision is a minimally invasive, brief, safe, outpatient procedure with a high UME cure rate.


Assuntos
Lasers de Estado Sólido , Slings Suburetrais , Incontinência Urinária por Estresse , Infecções Urinárias , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Telas Cirúrgicas , Qualidade de Vida , Cistoscopia , Slings Suburetrais/efeitos adversos , Incontinência Urinária por Estresse/cirurgia
6.
Obstet Gynecol ; 143(5): 633-643, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38547487

RESUMO

OBJECTIVE: To compare active with passive voiding trials on the rate of passing a trial of void and discharge rates with catheter in women who have undergone midurethral sling for treatment of stress urinary incontinence (SUI). DATA SOURCES: MEDLINE, EMBASE, and ClinicalTrials.gov were searched through February 24, 2023. METHODS OF STUDY SELECTION: Our population included women undergoing midurethral sling, with or without anterior or posterior repair, for treatment of SUI. Our two primary outcomes were rate of passing voiding trial and rate of discharge with a catheter. Our secondary outcome was the rate of delayed postoperative urinary retention, when a patient initially passes a trial of void but then subsequently presents in retention. TABULATION, INTEGRATION, AND RESULTS: Abstracts were doubly screened; full-text articles were doubly screened; and accepted articles were doubly extracted. In single-arm studies evaluating either passive or active voiding trial, random-effects meta-analyses of pooled proportions were used to assess outcomes. Of 3,033 abstracts screened, 238 full-text articles were assessed, and 26 met inclusion criteria. Ten studies including 1,370 patients reported active trial of void. Sixteen studies including 3,643 patients reported passive trial of void. We included five randomized controlled trials, five comparative retrospective studies, five prospective single group studies, and 11 retrospective single group studies. Five of the studies included patients with a concomitant anterior or posterior colporrhaphy. On proportional meta-analysis, the active trial of void group was less likely to pass the voiding trial (81.0%, 95% CI, 0.76-0.87% vs 89.0%, 95% CI, 0.84-0.9%3, P =.029) with high heterogeneity ( I2 =93.0%). Furthermore, there were more discharges with catheter in active trial of void compared with passive trial of void (19.0%, 95% CI, 0.14-0.24% vs 7.0%, 95% CI, 0.05-0.10%, P <.01). The rates of delayed postoperative urinary retention were low and not different between groups (0.6%, 95% CI, 0.00-0.02% vs 0.2%, 95% CI, 0.00-0.01%, P =.366) with low heterogeneity ( I2 =0%). Sling revisions were statistically lower in the active trial of void group (0.5%, 95% CI, 0.00-0.01% vs 1.5%, 95% CI, 0.01-0.02%, P =.035) with low heterogeneity ( I2 =10.4%). CONCLUSION: Passive trial of void had higher passing rates and lower discharge with catheter than active trial of void. Rates of most complications were low and similar between both groups, although passive trial of void had higher sling revisions. SYSTEMATIC REVIEW REGISTRATION: PROSPERO, CRD42022341318.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Retenção Urinária , Humanos , Feminino , Retenção Urinária/complicações , Estudos Retrospectivos , Slings Suburetrais/efeitos adversos , Estudos Prospectivos , Incontinência Urinária por Estresse/cirurgia , Complicações Pós-Operatórias/etiologia
7.
Urogynecology (Phila) ; 30(3): 174-180, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38484229

RESUMO

IMPORTANCE: There are no current data investigating the relationship between mesh-exposure complications after midurethral sling surgery and antiestrogen therapy. OBJECTIVES: We sought to determine if there are increased mesh-exposure complications between a breast cancer population versus a noncancer population particularly in conjunction with hormone suppression (HS) therapy. STUDY DESIGN: A retrospective chart review was performed on patients with a history of breast cancer undergoing tension-free vaginal tape (TVT) surgery at our institution between 2013 and 2021. A group of patients who underwent TVT surgery without a history of cancer served as our control. Univariate and multivariate logistic regression analyses were performed to identify predictors of mesh exposure complications. RESULTS: One hundred twenty-one patients with breast cancer had TVT surgery. Two hundred ninety-seven patients without cancer had TVT surgery during the same period. Baseline characteristics across all groups were similar. Twenty-nine patients (6.9%) experienced mesh exposure. This occurred at a higher rate in our cancer (15.7%) versus the noncancer population (3.4%). Women with breast cancer taking HS therapy had a higher rate of mesh exposure complications compared with those not taking HS therapy (25.0% versus 6.6%; P = 0.005). The highest rate of mesh exposure complications occurred in the cohort taking estrogen receptor modulators, selective estrogen receptor modulator (10/36 [27.8%]) versus aromatase inhibitors (5/24 [20.8%]) versus no HS therapy (4/61 [6.6%]; P = 0.014). On multivariate analysis, HS therapy use (odds ratio, 1.57; P = 0.007) and diabetes mellitus (odds ratio, 4.53; P = 0.018) were associated with increased TVT-related complications. CONCLUSION: Women with breast cancer had a higher rate of mesh exposure complications from TVT surgery compared with women without cancer, particularly those taking antiestrogenic therapy.


Assuntos
Neoplasias da Mama , Sobreviventes de Câncer , Slings Suburetrais , Humanos , Feminino , Estudos Retrospectivos , Neoplasias da Mama/tratamento farmacológico , Telas Cirúrgicas/efeitos adversos , Slings Suburetrais/efeitos adversos , Moduladores de Receptor Estrogênico/efeitos adversos
8.
Investig Clin Urol ; 65(2): 157-164, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38454825

RESUMO

PURPOSE: To examine efficacy and safety of ReMEEX implantation in patients with female stress urinary incontinence (SUI) associated with detrusor underactivity (DU), recurrence, or intrinsic sphincter deficiency (ISD). MATERIALS AND METHODS: Retrospective cohort study included 303 females who underwent ReMEEX system (March 2008 to May 2021). Patients were stratified into three groups by purpose of surgery (SUI with DU, reoperation, and SUI with ISD) and evaluated with following criteria: cure (absence of subjective complaint of leakage and objective leakage in the stress test), improvement (rare leakage subjectively, but satisfaction regardless of stress test), and failure. Primary outcome was success rate of surgery assessed through patient interviews and a stress test. Surgical outcomes and complications were evaluated. RESULTS: Mean follow-up was 34.4 months (range, 6.0-145.0 months). At the final follow-up visit, 42.9% and 49.2% of patients were cured and improved. Twenty-one point five percent required tension readjustment (mean number, 1.2). The total complication rate was 19.5% (none for grade ≥4). Preoperative Qmax was significantly higher in the ISD group (p<0.001) and preoperative total International Prostate Symptom Score (IPSS) score was significantly higher in the DU group (p=0.044). Moreover, at postoperative 1 year, both total IPSS score and IPSS quality of life score were significantly higher in the DU group (both p=0.001). CONCLUSIONS: The success rate of ReMEEX system was 92.1% at mean follow-up of 34.4 months in female SUI with DU, reoperation, or ISD. It also enabled postoperative readjustment of sling tension, as needed, up to 130 months after surgery.


Assuntos
Slings Suburetrais , Doenças Uretrais , Incontinência Urinária por Estresse , Masculino , Humanos , Feminino , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/complicações , Estudos Retrospectivos , Qualidade de Vida , Estudos de Viabilidade , Slings Suburetrais/efeitos adversos , Resultado do Tratamento
9.
Int Urogynecol J ; 35(5): 1021-1026, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520516

RESUMO

INTRODUCTION AND HYPOTHESIS: Single-incision slings (SIS) have emerged as a less invasive alternative to conventional slings for stress urinary incontinence (SUI) treatment. However, long-term efficacy and safety results remain uncertain owing to a lack of studies. MATERIAL AND METHODS: A retrospective review of 155 patients treated with Altis® for SUI between February 2012 and June 2017, held in 2022, as a continuation of a prospective study in which all patients (197) were reviewed for 2 years after surgery (1, 6, 12, and 24 months). Preoperative demographic data, comorbidities, and pressure-flow studies were also recorded. Continence status and satisfaction rates were assessed using the International Consultation on Incontinence Questionnaire-short form (ICIQ-SF) and the Patient Global Impression of Improvement (PGI-I) respectively. The assessment in the 2022 retrospective review was performed via a telephone survey. RESULTS: Mean follow-up time after surgery was 85.3 months (82.5-88.1). In 2022, complete continence was present in 75.4% of the patients. The presence of urinary urgency conditioned the ICIQ-SF score (10.9 vs 1.7 points, p < 0.01), with the ICIQ-SF = 0 in 84.5% of the patients with no associated urgency. Satisfaction assessed by the PGI-I was high, with 84.6% of the patients showing improvement. De novo urgency was present in 37,9% of the patients by 2022. Urinary tract infections were the most frequent complication (9.7%), with only 5 documented cases of mesh erosion. CONCLUSIONS: Altis® SIS is a safe and effective device for SUI treatment, with satisfaction rates comparable with those of the conventional slings. Persistence or development of urinary urgency influences the results.


Assuntos
Satisfação do Paciente , Slings Suburetrais , Incontinência Urinária por Estresse , Humanos , Slings Suburetrais/efeitos adversos , Incontinência Urinária por Estresse/cirurgia , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Seguimentos , Resultado do Tratamento , Idoso , Fatores de Tempo , Adulto
10.
Int Urogynecol J ; 35(4): 849-854, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38376548

RESUMO

INTRODUCTION AND HYPOTHESIS: Retropubic midurethral sling (MUS) placement is the gold standard for the treatment of stress urinary incontinence in the USA. The procedure can be approached from either a top-down or a bottom-up direction, but there is a paucity of contemporary data regarding outcomes between these approaches. The aim of this study was to provide updated clinical outcomes data. METHODS: This was a retrospective cohort study of women undergoing the retropubic MUS procedure alone or at the time of pelvic organ prolapse repair between 2010 and 2020 at a single academic medical center. The electronic medical record was used to extract demographic data, operative approach, and perioperative complications. The primary outcome was a composite incidence of any perioperative complication. RESULTS: Of the 309 patients analyzed, 140 (45.3%) underwent top-down and 169 (54.7%) underwent bottom-up retropubic MUS placement. Patients undergoing top-down MUS placement were more likely to be older (mean age 58 vs 54, p=0.02), have a history of diabetes mellitus (20% vs 8.9%, p=0.004), and have had a prior hysterectomy (27% vs 16%, p=0.02). They were less likely to have a concurrent anterior (p<0.001) or posterior repair (p<0.001). Patients undergoing the top-down procedure were less likely to experience sling exposure (p=0.02); complications in the two groups were otherwise similar. CONCLUSIONS: The top-down approach to retropubic MUS placement was associated with lower rates of mesh erosion in this population of patients. Neither approach is associated with an increased overall risk of complications or de novo overactive bladder symptoms.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Humanos , Slings Suburetrais/efeitos adversos , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Incontinência Urinária por Estresse/cirurgia , Resultado do Tratamento , Idoso , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Prolapso de Órgão Pélvico/cirurgia , Adulto
11.
Urol Pract ; 11(2): 402-408, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38305190

RESUMO

INTRODUCTION: Our objectives were to evaluate the Male Stress Incontinence Grading Scale to stratify male patients with stress urinary incontinence for either artificial urinary sphincter or sling using a standing cough test and determine if an emptier bladder at the time of assessment carries increased risk of treatment failure. METHODS: Retrospective chart review of male patients undergoing sling and artificial urinary sphincter placement. The standing cough test score and bladder scan results were documented at initial evaluation. RESULTS: Forty patients underwent sling and 43 underwent naïve artificial sphincter placement. Median follow-up was 7.11 months. Thirty-six/forty slings had complete incontinence resolution or reduction to a safety pad vs 40/43 after sphincter (90% vs 93%, P = .62). Four sling patients (10%) had persistence or recurrence of incontinence. Cough test scores were similar between sling failure (67% grade 0, 33% grade 1) and success groups (83% grade 0, 3% grade 1, 14% grade 2). Bladder scan mean was 18.5 cc in the sling failure (SD 21.1) and 38.0 cc in the success groups (38.3), with 32% of success patients having bladder scans of 0 cc, and 63% of < 50 cc. Mean for sphincter patients was 45 cc (56.9). Ten patients with scan = 0 and 7 patients with scans < 30 cc demonstrated grade 4 incontinence. CONCLUSIONS: Cough test is a noninvasive, reliable tool to assess stress urinary incontinence severity. Our data suggest it is reliable even when bladders are nearly empty and can effectively stratify patients for sling vs artificial urinary sphincter with a high rate of success.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Incontinência Urinária , Humanos , Masculino , Incontinência Urinária por Estresse/diagnóstico , Bexiga Urinária/diagnóstico por imagem , Estudos Retrospectivos , Slings Suburetrais/efeitos adversos , Incontinência Urinária/complicações , Tosse/diagnóstico
12.
Int Urogynecol J ; 35(4): 921-923, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38308690

RESUMO

INTRODUCTION AND HYPOTHESIS: Intravesical mesh is an uncommon complication following synthetic midurethral sling placement. Management options have included endoscopic techniques such as laser ablation or surgical excision. We present our technique for robotic-assisted excision of intravesical mesh following a retropubic midurethral sling. METHODS: The patient is a 66-year-old woman with a remote history of laser ablation of intraurethral mesh after midurethral sling, and persistent symptomatic intravesical mesh with associated stone at the bladder neck and right bladder wall. Robotic excision of the intravesical mesh and stone was performed by entering the space of Retzius, carrying the dissection along the right arm of the retropubic sling, performing two cystotomies to free and remove the mesh, and finally closing the cystotomies in two layers. RESULTS: The patient was discharged on postoperative day 1. A cystogram prior to catheter removal showed no extravasation and a competent bladder neck. She reported no new stress incontinence and had improvement in overactive bladder symptoms. CONCLUSIONS: Robotic excision of intravesical mesh after synthetic midurethral sling was safely performed in this patient who had multiple areas of intravesical mesh. Management aspects reported here may be helpful for complex presentations of intravesical mesh.


Assuntos
Procedimentos Cirúrgicos Robóticos , Slings Suburetrais , Telas Cirúrgicas , Idoso , Feminino , Humanos , Remoção de Dispositivo/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Slings Suburetrais/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Bexiga Urinária/cirurgia , Cálculos da Bexiga Urinária/cirurgia , Cálculos da Bexiga Urinária/etiologia , Incontinência Urinária por Estresse/cirurgia
13.
BJU Int ; 133 Suppl 3: 33-38, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37409820

RESUMO

OBJECTIVES: To evaluate the New Zealand clinical experience with the adjustable transobturator male system (ATOMS), a novel continence device in the management of all degrees of stress urinary incontinence (SUI), focusing on efficacy and safety outcomes. PATIENTS AND METHODS: A retrospective review of all ATOMS devices placed between May 2015 and November 2020 was conducted. Severity of SUI was assessed (pad usage) before and after surgery. SUI was defined as mild (1-<3 pads/day), moderate (≥3-5 pads/day) or severe (>5 pads/day). The primary outcome measures considered were the overall success rate (improvement in pad use) and the dry rate (with dry defined as either no or 1 safety pad/day). The number of outpatient adjustments and total filling volumes were also documented in each case. Additionally, we documented incidence and severity of device complications and an analysis of treatment failures. RESULTS: A total of 140 patients were reviewed, with the most common indication for ATOMS placement being SUI after radical prostatectomy (82.8%). Of the patients included, 53 (37.9%) had previous radiotherapy, with 26 (18.6%) patients having had a previous continence procedure performed. No intraoperative complications were noted. The median preoperative pad usage was 4 pads/day. After a median follow-up of 11 months, median postoperative pad usage reduced to 1 pad/day. In our cohort, 116 patients (82.9%) reported an improvement in their pad usage and were considered successful with 107 (76.4%) patients reporting themselves to be dry. Complications within the first 90-days after surgery occurred in 20 (14.3%) of patients. CONCLUSION: Treatment of SUI with the ATOMS is safe and effective. The option of long-term, minimally invasive adjustment to respond to patient needs is a significant advantage.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Humanos , Masculino , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Resultado do Tratamento , Slings Suburetrais/efeitos adversos , Desenho de Prótese , Prostatectomia/efeitos adversos
14.
Urogynecology (Phila) ; 30(1): 59-64, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37326287

RESUMO

IMPORTANCE: The low incidence of de novo overactive bladder (OAB) symptoms after a midurethral sling (MUS) procedure better informs preoperative counseling. OBJECTIVE: The study aimed to measure the incidence and risk factors for de novo OAB after MUS. STUDY DESIGN: This was a retrospective cohort study of de novo OAB symptoms in patients who underwent MUS surgery in a health maintenance organization between January 1, 2008, and September 30, 2016. Patients were identified using Current Procedural Terminology codes for MUS and International Classification of Diseases, Tenth Revision codes for urinary urgency, frequency, nocturia, OAB, and urgency urinary incontinence (UUI). The cohort of patients was identified by the absence of these International Classification of Diseases, Tenth Revision codes 12 months preoperatively and the presence of these codes within 6 months after surgery. This cohort was used to calculate the rate of de novo OAB after MUS surgery. Clinical and demographic factors were abstracted. Statistical analysis was performed using descriptive, χ2 , simple logistic, and multiple logistic regression. RESULTS: During the study period, 13,893 patients underwent MUS surgery and 6,634 met the inclusion criteria. The mean age was 56.9 years, mean parity was 2.76, and mean body mass index was 28.9 (calculated as weight in kilograms divided by height in meters squared). Of these, 410 (6.1%) developed de novo OAB within 12 months. The most common symptoms were urgency (65.4%), UUI (42.2%), and frequency (19.8%). On multivariable regression modeling, de novo urgency and UUI were not associated with concurrent surgery ( P < 0.05). Increasing age and body mass index were associated with an increased risk of nocturia ( P < 0.05). CONCLUSIONS: The incidence of de novo OAB after MUS surgery was 6.1%. This aligns with current literature and critically informs preoperative counseling for MUS surgery.


Assuntos
Noctúria , Slings Suburetrais , Bexiga Urinária Hiperativa , Incontinência Urinária por Estresse , Incontinência Urinária , Humanos , Pessoa de Meia-Idade , Bexiga Urinária Hiperativa/epidemiologia , Estudos Retrospectivos , Slings Suburetrais/efeitos adversos , Noctúria/complicações , Incontinência Urinária por Estresse/complicações , Incontinência Urinária/complicações , Fatores de Risco
15.
Int Urogynecol J ; 35(1): 43-50, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37428179

RESUMO

INTRODUCTION AND HYPOTHESIS: The mid-urethral sling (MUS) has been used for more than 30 years to cure stress urinary incontinence. The objective of this study was to assess whether surgical technique affects the outcome after more than ten years, regarding dyspareunia and pelvic pain. METHODS: In this longitudinal cohort study we used the Swedish National Quality Register of Gynecological Surgery to identify women who underwent MUS surgery in the period 2006-2010. Out of 4348 eligible women, 2555 (59%) responded to the questionnaire sent out in 2020-2021. The two main surgical techniques, the retropubic and the obturatoric approach, were represented by 1562 and 859 women respectively. The Urogenital Distress Inventory-6 (UDI-6) and the Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12), as well as general questions concerning the MUS surgery, were sent out to the study population. Dyspareunia and pelvic pain were defined as primary outcomes. Secondary outcomes included PISQ-12, general satisfaction, and self-reported problems due to sling insertion. RESULTS: A total of 2421 women were included in the analysis. Among these, 71% responded to questions regarding dyspareunia and 77% responded to questions regarding pelvic pain. In a multivariate logistic regression analysis of the primary outcomes, we found no difference in reported dyspareunia (15% vs 17%, odds ratio (OR) 1.1, 95% CI 0.8-1.5) or in reported pelvic pain (17% vs 18%, OR 1.0, 95% CI 0.8-1.3) between the retropubic and obturatoric techniques among study responders. CONCLUSION: Dyspareunia and pelvic pain 10-14 years after insertion of a MUS do not differ with respect to surgical technique.


Assuntos
Dispareunia , Slings Suburetrais , Incontinência Urinária por Estresse , Feminino , Humanos , Dispareunia/epidemiologia , Dispareunia/etiologia , Procedimentos Cirúrgicos Urológicos/métodos , Slings Suburetrais/efeitos adversos , Estudos Longitudinais , Incontinência Urinária por Estresse/cirurgia , Dor Pélvica/epidemiologia , Dor Pélvica/etiologia , Dor Pélvica/cirurgia , Resultado do Tratamento
16.
Curr Opin Urol ; 34(2): 135-144, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37933676

RESUMO

PURPOSE OF REVIEW: Mesh erosions following previous synthetic sling/mesh surgery for stress urinary incontinence (SUI) have become increasingly common. This systematic review provides evidence for the role of laser excision as a first-line management in patients with eroded mesh. RECENT FINDINGS: Fourteen articles (173 patients) were included for the final review. Among these, 138 patients (79.8%) were submitted to trans-urethral laser excision of eroded urethral/bladder mesh over a median time to presentation of 36.6 months. Over a median follow-up of 23.6 months, 88 (63.7%) reported a complete resolution, 32 (23.2%) reported persistence or recurrence of SUI and 17 (12.3%) presented with recurrent mesh erosion. The success rate after a single endoscopic procedure was 66.5, vs. 93.5% after additional endoscopic procedures, with only 9 (6.6%) requiring open surgical excision. Overall, there were seven (5.1%) postoperative complications including two urethrovaginal fistulas, two UTIs and haematuria each, and one case of urethral diverticulum. SUMMARY: Laser excision of eroded mid-urethral slings into either the bladder or urethra is a challenging complication of minimally invasive incontinence surgery. Laser excision was able to achieve a good success rate with single or staged endoscopic procedure with a low risk of complication. It represents a valid first treatment option, although patients should be managed in mesh referral centres in collaboration with uro-gynaecology teams.


Assuntos
Lasers de Estado Sólido , Slings Suburetrais , Incontinência Urinária por Estresse , Incontinência Urinária , Humanos , Telas Cirúrgicas/efeitos adversos , Endoscopia , Incontinência Urinária/cirurgia , Incontinência Urinária por Estresse/cirurgia , Slings Suburetrais/efeitos adversos
17.
J Minim Invasive Gynecol ; 31(2): 131-137, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37984515

RESUMO

STUDY OBJECTIVE: To investigate the feasibility and safety of the retropubic mid-urethral sling (MUS) procedure with a resorbable mesh implant made of poly-4-hydroxybutyrate (P4HB). DESIGN: A prospective clinical cohort study with 24 months follow-up. SETTING: A tertiary academic hospital. PATIENTS: Seventeen women with moderate to severe stress urinary incontinence (SUI). INTERVENTIONS: A retropubic MUS procedure with P4HB sling. MEASUREMENTS AND MAIN RESULTS: Seventeen women underwent an uncomplicated MUS procedure with a new sling made of resorbable P4HB. Following safety criteria, there has been no need to stop the study before 24 months' end point. Three serious adverse events were reported during follow-up: (1) inability to void urine after 1 week postsurgery, (2) a hysterectomy and bilateral oophorectomy performed due to a precancerous endometrial lesion at 16 months after initial MUS procedure and (3) exposed mesh with a part of device sheath left behind. These participants underwent an uncomplicated reintervention with no additional and/or permanent harm. Reinterventions because of failure of cure contained 3 second MUS procedures and one admission of urethral bulking agent. Seventy-six percent and 47 percent of patients were objectively cured of SUI at 12 and 24 months, respectively. CONCLUSIONS: Preliminary evidence suggests that a sling made of P4HB can be safely used for MUS procedures and could be an alternative for permanent polypropylene slings in patients that prefer the use of nonpermanent material.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Humanos , Feminino , Incontinência Urinária por Estresse/cirurgia , Slings Suburetrais/efeitos adversos , Implantes Absorvíveis , Estudos de Coortes , Seguimentos , Estudos Prospectivos , Procedimentos Cirúrgicos Urológicos/métodos
18.
Am J Obstet Gynecol ; 230(4): 428.e1-428.e13, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38008151

RESUMO

BACKGROUND: Midurethral slings are the gold standard for treating stress urinary incontinence, but their complications may raise concerns. Complications may differ by the approach used to place them. OBJECTIVE: This study aimed to compare serious complications and reoperations for recurrence after midurethral sling procedures when using the retropubic vs the transobturator route for female stress urinary incontinence. STUDY DESIGN: This analysis was of patients included in the French, multicenter VIGI-MESH register since February 2017 who received a midurethral sling for female stress urinary incontinence either by the retropubic or the transobturator route and excluded patients with single-incision slings. Follow-up continued until October 2021. Serious complications (Clavien-Dindo classification ≥ grade III) attributable to the midurethral sling and reoperations for recurrence were compared using Cox proportional hazard models including any associated surgery (hysterectomy or prolapse) and a frailty term to consider the center effect. Baseline differences were balanced by propensity score weighting. Analyses using the propensity score and Cox models were adjusted for baseline differences, center effect, and associated surgery. RESULTS: A total of 1830 participants received a retropubic sling and 852 received a transobturator sling in 27 French centers that were placed by 167 surgeons. The cumulative 2-year estimate of serious complications was 5.8% (95% confidence interval, 4.8-7.0) in the retropubic group and 2.9% (95% confidence interval, 1.9-4.3) in the transobturator group, that is, after adjustment, half of the retropubic group was affected (adjusted hazard ratio, 0.41; 95% confidence interval, 0.3-0.6). The cumulative 2-year estimate of reoperation for recurrence of stress urinary incontinence was 2.7% (95% confidence interval, 2.0-3.6) in the retropubic group and 2.8% (95% confidence interval, 1.7-4.2) in the transobturator group with risk for revision for recurrence being higher in the transobturator group after adjustment (adjusted hazard ratio, 1.9; 95% confidence interval, 1.2-2.9); this surplus risk disappeared after exclusion of the patients with a previous surgery for stress urinary incontinence. CONCLUSION: The transobturator route for midurethral sling placement is associated with a lower risk for serious complications but a higher risk for surgical reoperation for recurrence than the retropubic route. Despite the large number of surgeons involved, these risks were low. The data are therefore reassuring.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Feminino , Humanos , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Slings Suburetrais/efeitos adversos , Telas Cirúrgicas , Procedimentos Cirúrgicos Urológicos/métodos , Reoperação
19.
Int Urol Nephrol ; 56(3): 901-912, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37837505

RESUMO

OBJECTIVES: The aim of this study was to demonstrate the feasibility of a modified sling mid-urethral suspension + subcutaneous tunnel-double point fixation technique for the treatment of male urinary incontinence and to preliminarily evaluate the short-term clinical efficacy of this technique. PATIENTS AND METHODS: The clinical data of patients treated with the modified sling mid-urethral suspension + subcutaneous tunnel-double point fixation technique using a Pelvimesh pelvic floor repair patch as a sling were collected. The primary evaluation criteria were surgery-related indicators and daily urinal pad usage before and after treatment, and the secondary evaluation criteria were the corresponding incontinence scores and the results of surgery-related questionnaires. RESULTS: After 1-12 months of follow-up, seven patients were clinically cured. Follow-up 1 month after surgery showed that one patient (14.3%) used one pad daily, and six patients (85.7%) did not need pads. The incontinence quality of life questionnaire (I-QOL) scores at 3 days and 1 month postoperatively were 89.4 ± 2.5 and 88.1 ± 6.7, respectively, which were significantly higher than the preoperative scores (31.5 ± 18.9) (P < 0.05). The scores of the International Continence Control Association Incontinence Questionnaire Short Form (ICI-Q-SF) at 3 days and 1 month postoperatively were 3.2 ± 0.9 and 4.2 ± 1.7, respectively, which were significantly lower than the preoperative scores of 19.4 ± 5.0 (P < 0.05). In addition, the results of the surgery-related questionnaires were positive. No serious complications occurred in any of the patients. CONCLUSION: The modified sling mid-urethral suspension + subcutaneous tunnel-double point fixation technique for the treatment of male urinary incontinence patients is safe, effective, minimally invasive, and has few complications. However, further validation in large sample, randomized, comparative, and longer-term follow-up studies is still needed.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Incontinência Urinária , Humanos , Masculino , Incontinência Urinária por Estresse/etiologia , Qualidade de Vida , Projetos Piloto , Slings Suburetrais/efeitos adversos , Resultado do Tratamento
20.
Am J Obstet Gynecol ; 230(3): 308-314.e5, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38036163

RESUMO

OBJECTIVE: This study aimed to assess the risk of stress urinary incontinence recurrence and reoperation after a midurethral sling procedure in women with subsequent childbirth and to assess the effect of delivery mode on this risk. DATA SOURCES: An electronic database search was performed using MEDLINE with the OvidSP interface and PubMed, Embase, Web of Science, and the Cochrane Library up to September 20, 2023. STUDY ELIGIBILITY CRITERIA: This study included experimental and nonexperimental studies, composed of randomized controlled and observational (case-control, cohort, and cross-sectional) studies assessing the risk factors for stress urinary incontinence recurrence and reoperation after childbirth in women who had previously undergone a midurethral sling procedure for stress urinary incontinence. METHODS: Analysis was performed using RevMan (version 5.3; Cochrane Collaboration, Oxford, United Kingdom). Quantitative synthesis was used if the included studies were sufficient in numbers and homogeneity. The overall certainty of the evidence was assessed using criteria recommended by the Grading of Recommendations Assessment, Development, and Evaluation Working Group. RESULTS: A total of 2001 studies were identified, of which 6 were eligible for analysis, composed of 381 patients who had at least 1 childbirth after a midurethral sling procedure (study group) and 860 patients who underwent a midurethral sling without having a subsequent childbirth (control group). All included studies were observational, the patients' mean age at the time of the midurethral sling procedure ranged from 34 to 36 years, and the mean time from midurethral sling procedure to delivery ranged from 21 to 31 months. No difference in stress urinary incontinence recurrence (relative risk, 0.1.02; 95% confidence interval, 0.78-1.33) or reoperation (relative risk, 1.37; 95% confidence interval, 0.87-2.17) was found between the study and control groups. The average follow-up time among the included studies of this comparison was 9.8 years (range, 2-18). Furthermore, the mode of delivery (vaginal vs cesarean) did not seem to affect the risk of stress urinary incontinence recurrence. CONCLUSION: Subsequent pregnancy and childbirth did not increase the risk of stress urinary incontinence recurrence or reoperation after a midurethral sling procedure.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Gravidez , Humanos , Feminino , Pré-Escolar , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Slings Suburetrais/efeitos adversos , Estudos Transversais , Reoperação , Fatores de Risco , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Observacionais como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...