Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Dent Mater ; 34(3): e25-e35, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29395471

RESUMO

OBJECTIVES: To characterize the microstructure, mechanical properties, ionic release and tarnish resistance of conventional and experimental Ag-based soldering alloys for orthodontic applications. METHODS: Disk shaped specimens were prepared from four commercial Ag based soldering alloys [Dentaurum Universal Silver Solder (DEN), Orthodontic Solders (LEO), Ortho Dental Universal Solder (NOB), and Silver Solder (ORT)] and four experimental alloys Ag12Ga, Ag10Ga5Sn, Ag20In and Ag7Sn. The elemental composition and microstructure was determined by SEM/EDX and XRD analysis, while the mechanical properties were determined by Instrumented Indentation Testing. Ionic release of Ag, Cu, Zn, Ga, In and Sn was determined by ICP-EAS in 0.9% NaCl and Ringer's solutions after 28, 49 and 70 days. Tarnish resistance was also tested and colorimetry was applied to quantify the differences in color (DE) before and after immersion in testing media. DSC was used to determine the melting range of the experimental alloys. Mechanical properties, ionic release and DE were statistically compared by ANOVA and Holm-Sidak multiple comparison test (a=0.05). RESULTS: All commercially alloys belong to the Ag-Zn-Cu ternary system and consist a Ag rich face centered cubic (FCC) and Cu (FCC) phase. The former is the predominant phase also in experimental alloys. Conventional alloys demonstrated higherhardness, less ductility and lower melting rangers compared to experimental alloys. Immersion testing revealed the release of Cu and Zn ions from the commercially alloys and Ga ions from AgGa and AgGaSn while no ionic release was identified for AgIn and AgSn. All alloys failed tarnish testing according to ISO 10271 showing DE values much higher than the clinical acceptable limit (3.7). SIGNIFICANCE: The conventional Ag based soldering alloys showed substantial differences in their microstructure, mechanical properties and ionic release, and thus different clinical performance is anticipated. Ga, Sn and In might be employed as alloying addition to modify the properties of Ag brazing alloys.


Assuntos
Ligas Dentárias/química , Soldagem em Odontologia/instrumentação , Ortodontia , Prata/química , Colorimetria , Teste de Materiais , Microscopia Eletrônica de Varredura , Espectrometria por Raios X , Difração de Raios X
2.
Eur J Oral Implantol ; 9 Suppl 1(2): 165-77, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27314124

RESUMO

PURPOSE: To evaluate the clinical outcome of two implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses 5 years after loading. MATERIALS AND METHODS: Eighty consecutive patients were recruited. To be immediately loaded, implants had to be inserted with a minimum torque of 80 Ncm. Forty-six laser-welded titanium and 34 cast silver-palladium frameworks with resin teeth were initially delivered within 8 and 48 h, respectively. Outcome measures, evaluated by two independent assessors included prosthesis and implant failures, complications, marginal bone level changes, implant stability quotient (ISQ) values and patient satisfaction. RESULTS: Five years after loading one patient did not return to the control and 10 prostheses were remade. Two implants failed early in two patients, but they were successfully replaced. Thirty-six complications occurred in 28 patients but were all successfully treated. After 5 years, mean marginal bone loss was 0.69 mm, mean ISQ values decreased from 75.4 to 73.8, and all patients were fully satisfied with the therapy. A post-hoc comparison between the outcome of laser-welded and cast frameworks showed that laser-welded frameworks were affected by significantly more complications (19 patients out of 46 and 6 patients out of 34, respectively; difference in proportion = 0.23, 95% CI: 0.03 to 0.43; Pearson's chi-square test, P = 0.032), therefore such a framework construction should be considered as a long-term temporary prosthesis and not a definitive prosthesis. CONCLUSIONS: Immediately loaded mandibular cross-arch prostheses can be supported by only two implants up to 5 years, if made with a robust cast framework. Longer follow-ups (around 10 years) are still needed to know the prognosis of this treatment modality.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Prótese Total Inferior , Carga Imediata em Implante Dentário/métodos , Arcada Edêntula/cirurgia , Mandíbula/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Processo Alveolar/diagnóstico por imagem , Estudos de Coortes , Ligas Dentárias/química , Falha de Restauração Dentária , Soldagem em Odontologia/instrumentação , Planejamento de Dentadura , Feminino , Seguimentos , Humanos , Arcada Edêntula/reabilitação , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Complicações Pós-Operatórias , Estudos Prospectivos , Radiografia Interproximal , Resultado do Tratamento
3.
J Prosthet Dent ; 113(5): 467-74, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25749091

RESUMO

STATEMENT OF PROBLEM: Framework longevity is a key factor for the success of complete-arch prostheses and commonly depends on the welding methods. However, no consensus has been reached on the joint design and welding type for improving framework resistance. PURPOSE: The purpose of this study was to assess the effect of different joint designs and welding methods with tungsten inert gas (TIG) or laser to join titanium alloy bars (Ti-6Al-4V). MATERIAL AND METHODS: Seventy titanium alloy bar specimens were prepared (3.18 mm in diameter × 40.0 mm in length) and divided into 7 groups (n=10): the C-control group consisting of intact specimens without joints and the remaining 6 groups consisting of specimens sectioned perpendicular to the long-axis and rejoined using an I-, X30-, or X45-shaped joint design with TIG welding (TI, TX30, and TX45) or laser welding (LI, LX30, and LX45). The specimens were tested with 3-point bending. The fracture surfaces were first evaluated with stereomicroscopy to measure the weld penetration area and then analyzed with scanning electron microscopy (SEM). The data were statistically analyzed with 2-way ANOVA and the Tukey post hoc test, 1-way ANOVA and the Dunnett test, and the Pearson correlation test (α=.05). RESULTS: Specimens from the X30 and X45 groups showed higher flexural strength (P<.05) and welded area (P<.05) than specimens from the I groups, regardless of the welding type. TIG welded groups showed significantly higher flexural strength than the laser groups (P<.05), regardless of the joint design. TIG welding also resulted in higher welded areas than laser welding for the I-shaped specimens. No significant differences were found for the weld penetration area in the X45 group, either for laser or TIG welding. SEM analysis showed more pores at the fracture surfaces of the laser specimens. Fracture surfaces indicative of regions of increased ductility were detected for the TIG specimens. CONCLUSIONS: TIG welding resulted in higher flexural strength for the joined titanium specimens than laser welding. For both welding methods, X30- and X45-shaped joint designs resulted in higher flexural strength and welding penetration than the I-shaped joint design.


Assuntos
Ligas Dentárias/química , Soldagem em Odontologia/métodos , Titânio/química , Ligas , Soldagem em Odontologia/instrumentação , Elasticidade , Eletrodos , Humanos , Lasers , Teste de Materiais , Microscopia , Microscopia Eletrônica de Varredura , Gases Nobres/química , Maleabilidade , Porosidade , Estresse Mecânico , Propriedades de Superfície , Tungstênio/química
4.
Angle Orthod ; 85(4): 665-72, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25191838

RESUMO

OBJECTIVE: To compare metal ion release from samples welded with silver soldering and laser welding when immersed into mouthwashes with different ingredients. MATERIALS AND METHODS: A total of 72 samples were prepared: 36 laser welded and 36 silver soldered. Four samples were chosen from each subgroup to study the morphologic changes on their surfaces via scanning electron microscopy (SEM). Each group was further divided into four groups where the samples were submerged into mouthwash containing sodium fluoride (NaF), mouthwash containing sodium fluoride + alcohol (NaF + alcohol), mouthwash containing chlorhexidine (CHX), or artificial saliva (AS) for 24 hours and removed thereafter. Subsequently, the metal ion release from the samples was measured with inductively coupled plasma mass spectrometry (ICP-MS). The metal ion release among the solutions and the welding methods were compared. The Kruskal-Wallis and analysis of variance (ANOVA) tests were used for the group comparisons, and post hoc Dunn multiple comparison test was utilized for the two group comparisons. RESULTS: The level of metal ion release from samples of silver soldering was higher than from samples of laser welding. Furthermore, greater amounts of nickel, chrome, and iron were released from silver soldering. With regard to the mouthwash solutions, the lowest amounts of metal ions were released in CHX, and the highest amounts of metal ions were released in NaF + alcohol. SEM images were in accord with these findings. CONCLUSIONS: The laser welding should be preferred over silver soldering. CHX can be recommended for patients who have welded appliances for orthodontic reasons.


Assuntos
Ligas Dentárias/química , Soldagem em Odontologia/métodos , Lasers , Metais/química , Antissépticos Bucais/química , Aparelhos Ortodônticos , Prata/química , Clorexidina/química , Cromo/química , Cobre/química , Corrosão , Soldagem em Odontologia/instrumentação , Etanol/química , Humanos , Íons , Ferro/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Níquel/química , Saliva Artificial/química , Fluoreto de Sódio/química , Espectrofotometria Atômica/métodos , Fatores de Tempo , Zinco/química
5.
J Prosthet Dent ; 112(3): 606-12, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24656408

RESUMO

STATEMENT OF PROBLEM: The effect of microwave brazing on the strength properties of dental casting alloys is not yet known. PURPOSE: The purpose of this study was to compare the strength properties of preceramic brazed joints obtained by using a microwave oven and a conventional torch flame for a high noble alloy (Au-Pd). MATERIAL AND METHODS: A total of 18 tensile bars made of an Au-Pd ceramic alloy were fabricated. Six specimens were cut and joined with a high-fusing preceramic solder in a specially designed microwave oven, and 6 specimens were joined with a conventional natural gas/oxygen torch. The remaining 6 uncut specimens were tested as a control. All the specimens were subjected to testing with a universal testing machine. A 1-way ANOVA was performed for each strength property tested. RESULTS: The tensile strength of the uncut group was the highest (745 ±19 MPa), followed by the microwave group (420 ±68 MPa) and the conventional torch group (348 ±103 MPa) (P<.001); however, no significant difference in tensile strength was found between the microwave group and gas torch group. The tensile strength of the microwave group exceeded ANSI/ADA Standard No. 88, Dental Brazing Alloys (a joint standard of the American National Standards Institute and the American Dental Association). CONCLUSIONS: The microwave heating preceramic solder method demonstrated the excellent tensile strength of an Au-Pd alloy and may be an alternative way of joining alloys when a torch flame is contraindicated.


Assuntos
Soldagem em Odontologia/métodos , Ligas de Ouro/química , Micro-Ondas , Paládio/química , Apatitas/química , Porcelana Dentária/química , Soldagem em Odontologia/instrumentação , Análise do Estresse Dentário/instrumentação , Módulo de Elasticidade , Elasticidade , Humanos , Teste de Materiais , Gás Natural , Oxigênio , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
7.
J Prosthodont ; 23(2): 163-70, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23889889

RESUMO

PURPOSE: This study was conducted to measure and compare the effect of the soldering method (torch soldering or ceramic furnace soldering) used for soldering bars to bar-retained, implant-supported overdentures on the fit between the bar gold cylinder and implant transgingival abutment. MATERIALS AND METHODS: Thirty-two overdenture implant bars were manufactured and screw retained into two Bränemark implants, which were attached to a cow rib. The bars were randomly distributed in two groups: a torch-soldering group and a porcelain-furnace soldering group. Then all bars were cut and soldered using a torch and a ceramic furnace. The fit between the bar gold cylinders and implant transgingival abutments was measured with a light microscope on the opposite side to the screw tightening side before and after the bar soldering procedure. The data obtained were statistically processed for paired and independent data. RESULTS: The average misfit for all bars before soldering was 33.83 to 54.04 µm. After cutting and soldering the bars, the misfit increased up to a range of 71.74 to 78.79 µm. Both before and after the soldering procedure, the bars soldered using a torch showed a higher misfit when compared to the bars soldered using a porcelain furnace. After the soldering procedure, the misfit was slightly lower on the left side of the bars, which had been soldered using a ceramic furnace. CONCLUSIONS: According to our data, the soldering of bars using the torch or furnace oven soldering techniques does not improve the misfit of one-piece cast bars on two implants. The lower misfit was obtained using the porcelain furnace soldering technique.


Assuntos
Adaptação Marginal Dentária , Prótese Dentária Fixada por Implante , Soldagem em Odontologia/métodos , Retenção de Dentadura/instrumentação , Revestimento de Dentadura , Animais , Bovinos , Projeto do Implante Dentário-Pivô , Soldagem em Odontologia/instrumentação , Desenho de Equipamento , Ligas de Ouro/química , Teste de Materiais , Paládio/química , Distribuição Aleatória , Propriedades de Superfície
8.
Braz Dent J ; 24(2): 147-51, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23780359

RESUMO

Lack of passivity has been associated with biomechanical problems in implant-supported prosthesis. The aim of this study was to evaluate the passivity of three techniques to fabricate an implant framework from a Co-Cr alloy by photoelasticity. The model was obtained from a steel die simulating an edentulous mandible with 4 external hexagon analog implants with a standard platform. On this model, five frameworks were fabricated for each group: a monoblock framework (control), laser and TIG welding frameworks. The photoelastic model was made from a flexible epoxy resin. On the photoelastic analysis, the frameworks were bolted onto the model for the verification of maximum shear stress at 34 selected points around the implants and 5 points in the middle of the model. The stresses were compared all over the photoelastic model, between the right, left, and center regions and between the cervical and apical regions. The values were subjected to two-way ANOVA, and Tukey's test (α=0.05). There was no significant difference among the groups and studied areas (p>0.05). It was concluded that the stresses generated around the implants were similar for all techniques.


Assuntos
Ligas de Cromo/química , Prótese Dentária Fixada por Implante , Soldagem em Odontologia/métodos , Lasers , Gases em Plasma , Técnica de Fundição Odontológica , Projeto do Implante Dentário-Pivô , Implantes Dentários , Soldagem em Odontologia/instrumentação , Resinas Epóxi/química , Humanos , Arcada Edêntula/reabilitação , Mandíbula/patologia , Teste de Materiais , Modelos Dentários , Estresse Mecânico , Propriedades de Superfície , Soldagem/instrumentação , Soldagem/métodos
9.
Braz. dent. j ; 24(2): 147-151, Mar-Apr/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-675660

RESUMO

Lack of passivity has been associated with biomechanical problems in implant-supported prosthesis. The aim of this study was to evaluate the passivity of three techniques to fabricate an implant framework from a Co-Cr alloy by photoelasticity. The model was obtained from a steel die simulating an edentulous mandible with 4 external hexagon analog implants with a standard platform. On this model, five frameworks were fabricated for each group: a monoblock framework (control), laser and TIG welding frameworks. The photoelastic model was made from a flexible epoxy resin. On the photoelastic analysis, the frameworks were bolted onto the model for the verification of maximum shear stress at 34 selected points around the implants and 5 points in the middle of the model. The stresses were compared all over the photoelastic model, between the right, left, and center regions and between the cervical and apical regions. The values were subjected to two-way ANOVA, and Tukey's test (α=0.05). There was no significant difference among the groups and studied areas (p>0.05). It was concluded that the stresses generated around the implants were similar for all techniques.


Resumo A falta de passividade tem sido associada a problemas biomecânicos em próteses implantossuportadas. A proposta deste estudo foi avaliar, por meio da fotoelasticidade, a influência de três diferentes de fabricação de infraestrutura em liga de Co-Cr na passividade destas. O modelo foi obtido a partir de uma matriz de aço simulando uma mandíbula edêntula com 4 análogos de implantes de hexágono externo com plataforma padrão. Neste modelo, foram confeccionados cinco amostras para cada grupo: infraestruturas em monobloco, infraestruturas soldadas a laser e soldadas a TIG. O modelo fotoelástico foi feito com uma resina epóxi flexível (GIII, Polipox Industria e Comercio Ltda.). Na análise fotoelástica, as infraestruturas foram aparafusadas no modelo para a verificação da tensão de cisalhante máxima em 34 pontos selecionados ao redor dos implantes e 5 pontos na região média do modelo. Foram comparadas as tensões em todo o modelo fotoelástico, entre as regiões direita, esquerda e centro e também entre as regiões cervical e apical. Os valores foram submetidos à análise de variância a dois critérios, seguido pelo teste de Tukey (α=0,05). Os resultados não mostraram diferença significativa entre as tensões presentes nos grupos e nas áreas estudadas. Conclui-seque as tensões geradas ao redor dos implantes foram semelhantes entre as diferentes técnicas de confecção e entre todas as regiões analisadas. .


Assuntos
Humanos , Ligas de Cromo/química , Prótese Dentária Fixada por Implante , Soldagem em Odontologia/métodos , Lasers , Gases em Plasma , Técnica de Fundição Odontológica , Projeto do Implante Dentário-Pivô , Implantes Dentários , Modelos Dentários , Soldagem em Odontologia/instrumentação , Resinas Epóxi/química , Arcada Edêntula/reabilitação , Teste de Materiais , Mandíbula/patologia , Estresse Mecânico , Propriedades de Superfície , Soldagem/instrumentação , Soldagem/métodos
11.
Tex Dent J ; 129(4): 389-95, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22702018

RESUMO

BACKGROUND: Although dental implant treatment is a very successful option today, a meticulous treatment planning and close collaboration between the oral surgeon and restorative doctor is crucial to eliminate undesired outcomes. PURPOSE: To present a challenging case restored with a maxillary screw-retained fixed prosthesis using malpositioned/malaligned implants. MATERIALS AND METHODS: A 47-year-old female had a Lefort I fracture and lost all maxillary teeth due to traumatic injury in a traffic accident. Seven maxillary implants were placed using a 1-stage surgical approach, 6 months after open reduction surgery in a private practice. Radiographic and clinical evaluation indicated marginal bone loss around 3 anterior implants. The malposition and malalignment of implants made impression and casting procedures very complicated. The other challenging factors with this patient were microstomia, limited mouth opening due to scar tissue from previous plastic surgery, and a very small maxilla. The 1-piece metal framework did not fit accurately so it was sectioned into 3 segments. The 3 separate segments were screwed on the abutments individually, then connected to each other using an acrylic resin. The 3 framework segments were laser welded. After the laser welding, a passive fit of the framework was achieved. CONCLUSION: It has been suggested that providing an implant treatment to a patient with implants placed in wrong positions with undesired angulations can be very difficult. Also, laser welding may be a viable option to eliminate misfit of full-arch metal frameworks.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Arcada Edêntula/reabilitação , Fraturas Maxilares/reabilitação , Microstomia/complicações , Perda de Dente/reabilitação , Acidentes de Trânsito , Perda do Osso Alveolar/etiologia , Implantes Dentários/efeitos adversos , Soldagem em Odontologia/instrumentação , Feminino , Humanos , Lasers , Fraturas Maxilares/etiologia , Pessoa de Meia-Idade , Perda de Dente/etiologia
12.
Braz Dent J ; 23(6): 686-91, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23338261

RESUMO

The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks.


Assuntos
Ligas Dentárias/química , Soldagem em Odontologia/métodos , Gases em Plasma/química , Titânio/química , Ligas , Argônio/química , Ligas de Cromo/química , Soldagem em Odontologia/instrumentação , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Maleabilidade , Espectrometria por Raios X , Estresse Mecânico , Propriedades de Superfície , Soldagem/instrumentação , Soldagem/métodos
13.
Braz. dent. j ; 23(6): 686-691, 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-662427

RESUMO

The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks.


O objetivo deste estudo foi avaliar o efeito de diferentes parâmetros de solda a plasma verificando a resistência flexural de barras de liga de titânio (Ti-6Al-4V). Quarenta espécimes de Ti-6AL-4V e dez espécimes de liga de NiCr foram preparados (40 mm de altura e 3,18 mm de diâmetro) e divididos em 5 grupos (n=10). As barras de liga titânio do grupo controle não foram seccionadas e nem submetidas a processo de soldagem. Os grupos PL10, PL12 e PL14, continham barras de titânio seccionadas e soldadas com uma corrente de 3 A por períodos de 10,12 e 14 ms, respectivamente. O grupo NCB consistiu de barras de liga de NiCr soldadas pelo método de brasagem convencional. Em seguida as barras foram submetidas ao teste de flexão de três pontos e os valores obtidos foram transformados em resistência flexural (MPa). Análise estatística foi realizada usando ANOVA de fator único e o teste Tukey com o nível de significância de 0,05. Diferença estatística foi verificada entre os grupos avaliados (p<0,001), com os maiores valores pra o grupo controle. Não foram encontradas diferenças entre os grupos de solda plasma (p>0,05). O grupo NCB apresentou os menores valores de resistência flexural embora tenha sido estatisticamente semelhante ao grupo PL14. Não houve diferença significante na profundidade de penetração entre os grupos de solda plasma (p=0,05). Três espécimes representativos foram aleatoriamente selecionados para serem avaliados por meio de microscopia eletrônica de varredura. A composição das regiões soldadas foi verificada por meio de espectroscopia por energia dispersiva. Este estudo fornece informações iniciais de parâmetros para permitir a utilização de soldagem plasma durante a fabricação de estruturas em liga de titânio.


Assuntos
Humanos , Ligas Dentárias/química , Soldagem em Odontologia/métodos , Gases em Plasma/química , Titânio/química , Argônio/química , Ligas de Cromo/química , Soldagem em Odontologia/instrumentação , Teste de Materiais , Microscopia Eletrônica de Varredura , Maleabilidade , Espectrometria por Raios X , Estresse Mecânico , Propriedades de Superfície , Soldagem/instrumentação , Soldagem/métodos
14.
Indian J Dent Res ; 22(4): 614, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22124071

RESUMO

CONTEXT: Alloys have been considered to be of paramount importance in the field of prosthodontics. Long span prosthesis may often require joining of one or more individual castings to obtain better fit, occlusal harmony and esthetics in comparison to one-piece casting. AIM: This study was undertaken to evaluate the mechanical properties of base metal alloys joined by two different techniques, namely, gas oxygen torch soldering and laser fusion, compared to a one-piece casting. Mechanical properties evaluated were tensile strength, percentage of elongation and hardness of the solder joint. In addition, corrosion properties and scanning electron microscopic appearance of the joints were also evaluated. MATERIALS AND METHODS: The samples were prepared according to American Society for Testing Materials specifications (ASTM, E8). Specimens were made with self-cure acrylic and then invested in phosphate-bonded investment material. Casting was done in induction casting machine. Thirty specimens were thus prepared for each group and compared with 30 specimens of the one-piece casting group. STATISTICAL ANALYSIS USED: SPSS software (version 10.0, Chicago, IL, USA) was used for statistical analysis. ANOVA and Benferroni post hoc tests were done for multiple comparisons between the groups and within the groups for mean difference and standard error. RESULTS: Results showed that tensile strength of the one-piece casting was higher than laser fused and gas oxygen torch soldered joints. Laser fused joints exhibited higher hardness values compared to that of gas oxygen torch soldered joints. Scanning electron microscopic examination revealed greater porosity in the gas oxygen torch soldered joints. This contributed to the reduction in the strength of the joint. Gas oxygen torch soldered joints showed less corrosion resistance when compared to laser fused joints and one-piece casting. CONCLUSION: Laser fusion, which is a recent introduction to the field of prosthodontics, produces joints which have properties between those of one-piece casting and the gas oxygen torch soldering.


Assuntos
Ligas de Cromo/química , Soldagem em Odontologia/métodos , Corrosão , Técnica de Fundição Odontológica/instrumentação , Soldagem em Odontologia/instrumentação , Módulo de Elasticidade , Técnicas Eletroquímicas , Dureza , Humanos , Lasers de Estado Sólido , Teste de Materiais , Microscopia Eletrônica de Varredura , Porosidade , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
15.
Int J Oral Maxillofac Implants ; 26(5): e23-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22010097

RESUMO

Immediate placement of a definitive metal-resin implant-fixed complete prosthesis on four implants after flapless computed tomographic (CT)-guided surgery was compromised because of misfit due to a discrepancy in the position of an implant. However, the definitive prosthesis could be delivered on the day of surgery with the help of laser-welding procedures. Immediate loading of four maxillary implants with a definitive prosthesis might be a viable option using the laser-welding technique in case of misfit of the prosthesis.


Assuntos
Implantação Dentária Endóssea/métodos , Adaptação Marginal Dentária , Prótese Dentária Fixada por Implante , Prótese Total Imediata , Prótese Total Superior , Carga Imediata em Implante Dentário , Resinas Acrílicas/química , Desenho Assistido por Computador , Ligas Dentárias/química , Implantes Dentários , Materiais Dentários/química , Soldagem em Odontologia/instrumentação , Soldagem em Odontologia/métodos , Planejamento de Dentadura , Seguimentos , Humanos , Registro da Relação Maxilomandibular , Lasers , Masculino , Pessoa de Meia-Idade , Cirurgia Assistida por Computador
16.
J Prosthet Dent ; 105(1): 28-34, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21194585

RESUMO

STATEMENT OF PROBLEM: Welding or soldering of metal frameworks negatively affects the overall bond strength between the veneering ceramic and metal. PURPOSE: The purpose of this study was to evaluate the effect of soldering and laser-welding procedures on the bond strength between ceramic and metal. MATERIAL AND METHODS: Thirty Ni-based metal specimens (Wiron 99) (8 × 4 × 4 mm) were fabricated and divided into 3 groups; soldered (S), laser welded (L), and control (untreated cast alloy) (n=10). In S and L specimens, a notch (1 × 1.5 mm) was prepared longitudinally on the surface of each specimen and filled with compatible alloy (Wiron soldering rods and Wiroweld NC, respectively). Vickers hardness measurements were made after polishing the surfaces with a metallographic polishing kit. A veneering ceramic (VITA VMK 95) was vibrated, condensed in a mold, and fired on the metal frameworks. The specimens were sectioned in 2 axes to obtain nontrimmed bar specimens with a bonding area of approximately 1 mm². Forty bars per block were obtained. Each bar was subjected to microtensile bond strength (µTBS) testing with a crosshead speed of 1 mm/min. The µTBS data (MPa) were recorded, and SEM was used for failure analysis of the tested bars. The measurements were statistically analyzed using a 1-way ANOVA and Tamhane tests (α=.05). RESULTS: The mean differences in µTBS of veneering ceramic to soldered (10.4 ±2.4 MPa) and laser-welded (11.7 ±1.3 MPa) metal surfaces were not significantly different and were significantly lower than that of the cast alloy (25.4 ±3.6 MPa) (P<.05). The mean Vickers hardness of cast alloy was significantly higher (236 ±17 HV) than soldered (114 ±9 HV) and laser-welded groups (129 ±11 HV) (P<.05). CONCLUSIONS: Soldering and laser welding significantly decreased the µTBS of a veneering ceramic to a base metal alloy.


Assuntos
Colagem Dentária , Porcelana Dentária/química , Soldagem em Odontologia/métodos , Lasers de Estado Sólido , Ligas Metalo-Cerâmicas/química , Óxido de Alumínio/química , Compostos Inorgânicos de Carbono/química , Ligas de Cromo/química , Ligas Dentárias/química , Revestimento para Fundição Odontológica/química , Corrosão Dentária/métodos , Polimento Dentário/métodos , Soldagem em Odontologia/instrumentação , Análise do Estresse Dentário/instrumentação , Facetas Dentárias , Módulo de Elasticidade , Elasticidade , Dureza , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Níquel/química , Compostos de Silício/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Resistência à Tração
17.
Lasers Med Sci ; 26(4): 415-20, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20437262

RESUMO

The Nd:YAG laser has been used since 1970 in dental laboratories to weld metals on dental prostheses. Recently in several clinical cases, we have suggested that the Nd:YAG laser device commonly utilized in the dental office could be used to repair broken fixed, removable and orthodontic prostheses and to weld metals directly in the mouth. The aim of this work was to evaluate, using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and dynamic mechanical analysis (DMA), the quality of the weld and its mechanical strength, comparing a device normally used in dental laboratory and a device normally used in the dental office for oral surgery, the same as that described for intraoral welding. Metal plates of a Co-Cr-Mo dental alloy and steel orthodontic wires were subjected to four welding procedures: welding without filler metal using the laboratory laser, welding with filler metal using the laboratory laser, welding without filler metal using the office laser, and welding with filler metal using the office laser. The welded materials were then analysed by SEM, EDS and DMA. SEM analysis did not show significant differences between the samples although the plates welded using the office laser without filler metal showed a greater number of fissures than the other samples. EDS microanalysis of the welding zone showed a homogeneous composition of the metals. Mechanical tests showed similar elastic behaviours of the samples, with minimal differences between the samples welded with the two devices. No wire broke even under the maximum force applied by the analyser. This study seems to demonstrate that the welds produced using the office Nd:YAG laser device and the laboratory Nd:YAG laser device, as analysed by SEM, EDS and DMA, showed minimal and nonsignificant differences, although these findings need to be confirmed using a greater number of samples.


Assuntos
Ligas Dentárias/química , Instrumentos Odontológicos , Soldagem em Odontologia/instrumentação , Lasers de Estado Sólido/uso terapêutico , Soldagem/instrumentação , Odontologia/métodos , Análise de Falha de Equipamento , Humanos
18.
J Oral Rehabil ; 38(3): 196-201, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20678101

RESUMO

This study was conducted to evaluate the fatigue strength of Ti-6Al-4V laser-welded joints with several diameters and joint openings. Sixty dumbbell rods were machined in Ti-6Al-4V alloy with central diameters of 1·5, 2·0 and 3·5 mm. The specimens were sectioned and then welded using two joint openings (0·0 and 0·6 mm). The combination of variables created six groups, which when added to the intact groups made a total of nine groups (n = 10). Laser welding was executed as follows: 360 V per 8 ms (1·5 and 2·0 mm) and 380 V per 9 ms (3·5 mm) with focus and frequency regulated to zero. The joints were finished, polished and submitted to radiographic examination to be analysed visually for the presence of porosity. The specimens were then subjected to a mechanical cyclic test, and the number of cycles until failure was recorded. The fracture surface was examined with a scanning electron microscope (SEM). The Kruskal-Wallis test and Dunn test (α = 0·05) indicated that the number of cycles required for fracture was lower for all specimens with joint openings of 0·6 mm, and for 3·5-mm-diameter specimens with joint openings of 0·0 mm. The Spearman correlation coefficient (α = 0·05) indicated that there was a negative correlation between the number of cycles and the presence of porosity. So, laser welding of Ti-6Al-4V structures with a thin diameter provides the best conditions for the juxtaposition of parts. Radiographic examination allows for the detection of internal voids in titanium joints.


Assuntos
Ligas Dentárias/química , Soldagem em Odontologia/métodos , Lasers de Estado Sólido , Titânio/química , Ligas , Óxido de Alumínio/química , Corrosão Dentária/métodos , Implantes Dentários , Polimento Dentário/métodos , Soldagem em Odontologia/instrumentação , Análise do Estresse Dentário/instrumentação , Revestimento de Dentadura , Prótese Parcial Fixa , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Porosidade , Radiografia Interproximal , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
19.
Eur J Prosthodont Restor Dent ; 18(2): 60-5, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20698419

RESUMO

The tensile strength and depth of weld of two cobalt chromium alloys before and after laser welding with and without an argon gas atmosphere were investigated. Using two cobalt chromium alloys, rod shaped specimens (5 cm x 1.5 mm) were cast. Specimens were sand blasted, sectioned and welded with a pulsed Nd: YAG laser welding machine and tested in tension using an Instron universal testing machine. A statistically significant difference in tensile strength was observed between the two alloys. The tensile strength of specimens following laser welding was significantly less than the unwelded controls. Scanning electron microscopy showed that the micro-structure of the cast alloy was altered in the region of the weld. No statistically significant difference was found between specimens welded with or without an argon atmosphere.


Assuntos
Ligas de Cromo/química , Soldagem em Odontologia/instrumentação , Soldagem/instrumentação , Argônio , Cobalto , Técnica de Fundição Odontológica , Análise do Estresse Dentário , Planejamento de Dentadura , Lasers de Estado Sólido , Teste de Materiais , Resistência à Tração
20.
J Prosthodont ; 19(5): 403-5, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20345739

RESUMO

This article describes a technique for the fabrication of a laser-welded hollow pontic full-gold fixed dental prosthesis. Reference to any specific commercial products, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the U.S. Government. The opinions of the authors expressed herein do not necessarily state or reflect those of the U.S. Government, and shall not be used for advertising or product endorsement purposes.


Assuntos
Soldagem em Odontologia/métodos , Planejamento de Dentadura , Prótese Parcial , Ligas de Ouro/química , Lasers , Resinas Acrílicas/química , Materiais Dentários/química , Soldagem em Odontologia/instrumentação , Humanos , Ceras/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...