Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transplantation ; 80(9): 1269-74, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16314795

RESUMO

BACKGROUND: Belzer solution is considered to be the best preservation media used for pancreas transplantation; however, its high cost accounts for approximately 14.5% of all resources allocated by the Brazilian government toward each pancreatic transplant. The objective of the present study was to test a reduction of Belzer solution during pancreas harvest, thereby lowering procedural cost. METHODS: The patients received pancreas-kidney transplantations during the period from January 2003 to August 2004. Patients were divided into two groups. Patients assigned to Group A (n=30) received only Belzer solution (2 L through the aorta artery), whereas patients in Group B (n=16) were perfused first with 1 L of Eurocollins solution followed by 1 L of Belzer solution. The two groups were assessed for differences in the following clinical parameters: the need for insulin replacement or antifungal and anticytomegalovirus treatment, pancreatitis, acute cellular rejection, graft vascular thrombosis, fistulas, intra-abdominal collection, graft loss, deaths, pancreatic ischemia time, and average hospitalization time. RESULTS: No statistically significant differences were observed in any of the parameters analyzed (P<0.05). The use of Eurocollins solution, followed by Belzer solution during pancreas harvesting, did not result in differences in graft survival or functionality, postsurgical complications, or patient survival and hospitalization time, when compared to the use of Belzer solution alone. CONCLUSIONS: Perfusion with 1 L of Eurocollins solution followed by 1 L of Belzer solution during pancreas harvesting seems to be a simple and efficient alternative for reducing the costs of the harvesting process.


Assuntos
Aorta , Soluções Hipertônicas/normas , Soluções para Preservação de Órgãos/normas , Pâncreas , Coleta de Tecidos e Órgãos , Adenosina/economia , Adulto , Alopurinol/economia , Controle de Custos , Custos de Medicamentos , Feminino , Glutationa/economia , Humanos , Insulina/economia , Tempo de Internação , Masculino , Soluções para Preservação de Órgãos/economia , Pâncreas/fisiopatologia , Transplante de Pâncreas/efeitos adversos , Rafinose/economia , Análise de Sobrevida , Irrigação Terapêutica , Sobrevivência de Tecidos , Coleta de Tecidos e Órgãos/economia , Coleta de Tecidos e Órgãos/métodos
2.
Thromb Res ; 107(5): 255-61, 2002 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-12479887

RESUMO

Resuscitation with hypertonic saline (HS) appears to aggravate bleeding in a model of uncontrolled hemorrhage [J. Trauma 28 (1988) 751; J. Trauma 29 (1989) 79; Arch. Surg. 127 (1992) 93]. This property may be related to the anticoagulant effects of HS on plasma clotting factors and platelets [J. Trauma 31 (1991) 8]. The hypothesis in this study is that a hypertonic solution can be developed that would not disturb the blood coagulation mechanism and could be used as an alternative to hypertonic saline.HS and four different 2400 mosM solutions containing monosaccharides and/or glycine were screened for their in vitro effects on plasma clotting times and platelets. Significant prolongations falling outside the normal range were detected in prothrombin time (PT) and thrombin rime (TT) when only 5% of the volume of normal plasma is HS. Platelet function as measured by extent of shape change (ESC) induced by ADP and aggregation induced by thrombin were also critically impaired by HS at a 5% dilution. All alternative solutions-hypertonic glucose, sorbitol, glycine, glucose/glycine, glucose/mannitol/glycine, sorbitol/glycine-caused a significantly reduced impairment in platelet function and the plasma coagulation system. Hypertonic glycine showed a unique ability to fully preserve the function and integrity of the plasma coagulation system. Considering the pre-deposition of the trauma patient to coagulopathy, administration of HS which clearly is a potent anticoagulant and anti-platelet risks further aggravating the coagulopathy. In contrast, hypertonic glycine preserves the blood coagulation mechanism and exhibits the potential for numerous therapeutic applications. Therefore, prompt evaluation of hypertonic glycine as a resuscitative fluid is highly desirable.


Assuntos
Coagulação Sanguínea/efeitos dos fármacos , Soluções Hipertônicas/efeitos adversos , Testes de Coagulação Sanguínea , Plaquetas/efeitos dos fármacos , Avaliação de Medicamentos , Glicina/farmacologia , Humanos , Soluções Hipertônicas/química , Soluções Hipertônicas/normas , Soluções Hipertônicas/uso terapêutico , Monossacarídeos/farmacologia , Plasma/efeitos dos fármacos , Ativação Plaquetária/efeitos dos fármacos , Testes de Função Plaquetária
4.
Transplantation ; 57(5): 649-55, 1994 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-8140626

RESUMO

The aim of the study was to delineate the most optimal preservation conditions for small bowel grafts. Established preservation solutions such as EuroCollins, University of Wisconsin, histidine-tryptophane-ketoglutarate-Brettschneider, phosphate-buffered sucrose (PBS 140), and 3 new solutions--extracellular fluid (ECF), lactobionate fructose, and a modified lactobionate fructose solution--were compared with saline to determine the most optimal solution for the intestine. Recipient survival, standard histology, and glutaminase activity were used to assess the degree of injury encountered after 12 hr of preservation followed by transplantation. To evaluate the various preservation conditions, ECF was used at pH 6.8 (original ECF). Grafts were preserved most optimally when a vascular washout after the cold storage period was omitted and when topical rewarming of the graft with 37 degrees C saline before reperfusion was performed. Graft survival was not significantly different after preservation with any solution tested (50-83%). Highest graft survival (83%) was achieved with lactobionate fructose and PBS140. Histologic evaluation 20 min after reperfusion revealed minor differences between most groups; a slight advantage was observed for PBS140-preserved grafts. Mucosal glutaminase activity of PBS140-preserved grafts was significantly higher 20 min after reperfusion compared with any other solution evaluated, indicating a superior graft function. These data indicate that different preservation conditions have a great impact on postoperative graft survival and that PBS140 might be preferable to any of the other preservation solutions tested.


Assuntos
Intestino Delgado , Soluções para Preservação de Órgãos , Preservação de Órgãos , Soluções/normas , Adenosina/normas , Alopurinol/normas , Animais , Criopreservação , Estudos de Avaliação como Assunto , Glutaminase/metabolismo , Glutationa/normas , Sobrevivência de Enxerto/fisiologia , Soluções Hipertônicas/normas , Insulina/normas , Mucosa Intestinal/enzimologia , Intestino Delgado/anatomia & histologia , Masculino , Preservação de Órgãos/métodos , Rafinose/normas , Ratos , Ratos Endogâmicos Lew , Fatores de Tempo
5.
HPB Surg ; 4(4): 313-20, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1810373

RESUMO

To compare UW-solution (UW) and Euro-Collins (EC) for long-term liver preservation we investigated the morphology and metabolic capacity of rat liver after 18 and 42-hours cold-storage in either UW or EC. After harvesting the rat liver was transferred to a perfusion chamber where it was perfused for 10 min with UW or EC at 4 degrees C. Thereafter livers were stored at 4 degrees C in UW or EC for 18 hours (both groups n = 6) or for 42 hours (both groups n = 8). After 18-hr or 42-hr cold-storage a 2-hr warm perfusion (37 degrees C) was started with Krebs-Ringer solution with carbogen to which 125Iodine-triiodothyronine (T3) was added. Control livers (n = 8) were immediately perfused with Krebs-Ringer without cold-storage. The following parameters were assessed: ASAT-levels in the perfusate, T3-metabolites in the bile and the perfusate, the perfusion pressure, the volume of bile secreted and light-microscopical morphology at the end of the warm perfusion period. After cold storage in UW-solution the ASAT-levels in the perfusate were lower than after storage in EC as well as the perfusion pressures. These livers demonstrated a better T3-metabolism and secreted more bile than EC-stored livers. Histological examination showed more tissue damage in the EC-stored livers than in the UW stored livers. We conclude that cold-storage of rat liver in UW-solution resulted in a better morphology and metabolic capacity as compared with EC-solution.


Assuntos
Soluções Hipertônicas/normas , Fígado/anatomia & histologia , Soluções para Preservação de Órgãos , Reperfusão , Soluções/normas , Preservação de Tecido/normas , Adenosina , Alopurinol , Animais , Aspartato Aminotransferases/metabolismo , Bile/metabolismo , Avaliação Pré-Clínica de Medicamentos , Glutationa , Insulina , Fígado/metabolismo , Masculino , Rafinose , Ratos , Ratos Endogâmicos , Preservação de Tecido/métodos , Tri-Iodotironina/metabolismo , Tri-Iodotironina/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...