Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Blood Press ; 31(1): 9-18, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35037533

RESUMO

PURPOSE: Although 24-hour ambulatory blood pressure measurement (24-h ABPM) is the most important method to establish true hypertension, in clinical practice often repeated automated office blood pressure (AOBP) measurements are used because of convenience and lower costs. We aimed to assess the agreement rate between a 30 and 60 min AOBP and 24-h ABPM. MATERIALS AND METHODS: Patients with known hypertension (cohort 1) and patients visiting the neurology outpatient clinic after minor stroke or transient ischaemic attack (cohort 2) were selected. We performed AOBP for 30-60 min at 5-min intervals followed by 24-h ABPM and calculated average values of both measurements. Agreement between the two methods was studied with McNemar and Bland-Altman plots with a clinically relevant limit of agreement of ≤10 mm Hg difference in systolic BP. RESULTS: Our final cohort consisted of 135 patients from cohort 1 and 72 patients from cohort 2. We found relatively low agreement based on the clinical relevant cut-off value; 64.7% of the measurements were within the limits of agreement for 24-h systolic and 50.2% for 24-h diastolic. This was 61.4% for daytime systolic and 56.6% for daytime diastolic. In 73.5% of the patients, both methods led to the same diagnosis of either being hypertensive or non-hypertensive. This resulted in a significant difference between the methods to determine the diagnosis of hypertension (p < 0.0001). CONCLUSION: We conclude that 30-60 min AOBP measurements cannot replace a 24-h ABPM and propose to perform 24-h ABPM at least on a yearly basis to confirm AOBP measurements.


Assuntos
Hipertensão , Sopros Sistólicos , Instituições de Assistência Ambulatorial , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Monitorização Ambulatorial da Pressão Arterial/métodos , Humanos , Hipertensão/diagnóstico , Sopros Sistólicos/diagnóstico
2.
Blood Press ; 30(1): 75-78, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32870038

RESUMO

In this report we present a case of missed hypertension due to subclavian artery stenosis. A 77 year-old female patient, initially thought as being normotensive, was referred to us due to newly discovered systolic heart murmur suspicious for aortic stenosis. We noted inter-arm blood pressure difference of 30 mmHg, with higher, hypertensive values on right arm. Further workup and medical imaging excluded aortic stenosis and revealed an asymptomatic, hemodynamically significant, stenosis of left subclavian artery. Due to absence of symptoms, the patient has been managed with conservative therapy for subclavian stenosis and hypertension, and she is currently in good conditions and followed up for any signs of disease progression. This case clearly shows importance of measuring blood pressure on both arms when initially diagnosing hypertension as this is often overlooked and is key to properly diagnose hypertension and possible subclavian stenosis.


Assuntos
Hipertensão/diagnóstico , Síndrome do Roubo Subclávio/diagnóstico , Sopros Sistólicos/diagnóstico , Idoso , Pressão Sanguínea , Feminino , Humanos , Artéria Subclávia/patologia
5.
Heart ; 105(2): 110, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30093542

RESUMO

CLINICAL INTRODUCTION: A 59-year-old woman visited an outpatient cardiology clinic due to shortness of breath on exertion. Physical examination showed no significant abnormality of vital signs. A III/VI systolic murmur was heard on the fourth intercostal space at the right sternal border. The majority of laboratory tests were normal. Chest X-ray showed a curved vessel shadow (figure 1A). Initial transthoracic echocardiography showed abnormal blood flow into the inferior vena cava (IVC) in the subxiphoid long axis view (figure 1B) and mild right heart dilatation (online supplementary figure 1). Transoesophageal echocardiography showed severe tricuspid regurgitation (online supplementary figure 2).heartjnl;105/2/110/F1F1F1Figure 1(A) Chest X-ray. (B) Colour Doppler image in the subxiphoid long axis view.DC1SP110.1136/heartjnl-2018-313655.supp1Supplementary data DC2SP210.1136/heartjnl-2018-313655.supp2Supplementary data QUESTION: What is the most likely underlying disease for the patient's shortness of breath on exertion?Pulmonary arteriovenous fistula.Pulmonary arterial hypertension.Lung cancer.Partial anomalous pulmonary venous connection.Isolated tricuspid regurgitation.


Assuntos
Fístula Arteriovenosa/diagnóstico , Dispneia/etiologia , Eletrocardiografia , Esforço Físico/fisiologia , Artéria Pulmonar/anormalidades , Veias Pulmonares/anormalidades , Sopros Sistólicos/etiologia , Fístula Arteriovenosa/complicações , Diagnóstico Diferencial , Dispneia/diagnóstico , Ecocardiografia , Feminino , Humanos , Pessoa de Meia-Idade , Radiografia Torácica , Sopros Sistólicos/diagnóstico
7.
Congenit Heart Dis ; 12(4): 417-420, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28299882

RESUMO

OBJECTIVE: Bicuspid aortic valve (BAV) disease is associated with potential lifetime complications, but auscultation of a BAV click is commonly missed or mistaken for a benign split first heart sound. Our objective was to determine whether pediatric cardiologists could reliably distinguish between BAV clicks and benign split first heart sounds. DESIGN: Quality evaluation project using de-identified recordings from an outpatient pediatric cardiology clinic. OUTCOME MEASURES: Twenty-one cardiologists listened to five de-identified recordings of pediatric heart sounds (three with BAV clicks, two with mitral components of benign split first heart sounds) and indicated whether they believed each recording was a BAV or split first heart sound. The accuracy of diagnoses was determined using percent agreement and calculated kappa coefficients for the cohort and subgroups based on those with less than 10 years of experience versus those with ≥10 years. To assess precision, a kappa extension was used for multiple raters to assess interrater agreement. RESULTS: Among participants, diagnostic accuracy of BAV click was 38%, while accuracy of split first heart sound was 41%. No participant correctly diagnosed all sounds. No difference in agreement was observed when stratifying by experience. Kappa was -0.11 (CI 95% -0.31 to 0.08) for all raters, -0.03 (CI 95% -0.39 to 0.33) for those with less than 10 years' experience, and -0.15 (CI 95% -0.38 to 0.08) for those with ≥10 years' experience. The kappa statistic among the 21 raters was 0.01 (95% CI -0.03 to 0.04), indicating poor precision among the raters. CONCLUSIONS: In this sample of pediatric cardiologists, the diagnostic accuracy of BAV clicks versus split first heart sounds was worse than chance. There was no association between years of experience and diagnostic accuracy. While further study is needed, these data suggest that an echocardiogram may be valuable when either a systolic ejection click or split first heart sound is heard.


Assuntos
Valva Aórtica/anormalidades , Cardiologistas/normas , Competência Clínica , Auscultação Cardíaca/métodos , Ruídos Cardíacos , Doenças das Valvas Cardíacas/diagnóstico , Sopros Sistólicos/diagnóstico , Doença da Válvula Aórtica Bicúspide , Criança , Humanos , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
J Clin Anesth ; 37: 163-165, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28235514

RESUMO

The danger of anaphylaxis, a rare but life threatening complication of general anesthesia (GA) can be summarized in two: 1. General Anesthesia masks the typical early signs of allergy which can be seen in an awake patient. 2. Anaphylaxis during GA manifests mostly as circulatory/ventilatory failures which can be interpreted as adverse effects of anesthetics or surgery and this can lead to critical delay of effective therapy. A 19-year-old female admitted for posterior spinal fusion and instrumentation (the 5th surgery in patient's life) desaturated seconds after intubation. Cardiopulmonary resuscitation (CPR) was started and the absence of cutaneous signs along with a loud holosystolic murmur were questioned. The patient was promptly resuscitated and allergy to rocuronium was confirmed by intradermal tests 6weeks later. Factors influencing decision making and potential etiology of the newly heard holosystolic murmur during anaphylaxis are discussed.


Assuntos
Anafilaxia/diagnóstico , Androstanóis/efeitos adversos , Anestesia Geral/efeitos adversos , Hipersensibilidade a Drogas/diagnóstico , Fármacos Neuromusculares não Despolarizantes/efeitos adversos , Choque/diagnóstico , Fusão Vertebral/efeitos adversos , Adulto , Anafilaxia/induzido quimicamente , Anafilaxia/terapia , Androstanóis/administração & dosagem , Anestésicos Intravenosos , Reanimação Cardiopulmonar , Tomada de Decisão Clínica , Hipersensibilidade a Drogas/terapia , Feminino , Fentanila/administração & dosagem , Humanos , Hipotensão/etiologia , Testes Intradérmicos , Fármacos Neuromusculares não Despolarizantes/administração & dosagem , Propofol/administração & dosagem , Rocurônio , Escoliose/cirurgia , Choque/induzido quimicamente , Choque/terapia , Sopros Sistólicos/diagnóstico , Sopros Sistólicos/etiologia , Vasoconstritores/uso terapêutico , Adulto Jovem
9.
J Assoc Physicians India ; 64(8): 96-97, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27762124

RESUMO

A 14 years asymptomatic male was evaluated for a grade 3/6 systolic murmur along lower left parasternal region. Color Doppler evaluation revealed turbulent systolic flow across moderator band with a peak systolic gradient of 127.2 mm hg. There was no other abnormality. This anomaly should be considered in differential diagnosis of systolic murmur in tricuspid area.


Assuntos
Ventrículos do Coração/fisiopatologia , Sopros Sistólicos/etiologia , Adolescente , Humanos , Masculino , Sopros Sistólicos/diagnóstico
11.
Wien Klin Wochenschr ; 128(9-10): 348-53, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26659701

RESUMO

AIM: The aim of this study was to assess the usefulness of a pocket-size imaging device in the hands of a noncardiologist as a screening tool for diagnosing aortic stenosis in individuals with newly discovered systolic murmur. METHODS AND RESULTS: A total of 200 consecutive patients with systolic murmur were included; a limited focused cardiac ultrasound was performed with a pocket-size imaging device and compared to standard echocardiography. It was performed by a noncardiologist with no formal training in echocardiography. In all, 150 patients had morphological changes on the aortic valve, 77 had more than mild aortic stenosis, 30 had more than mild mitral regurgitation, 64 patients had more than moderate hypertrophy, 113 had more than moderately enlarged left atriums, and 3 had severely enlarged left ventricles. There were no significant difference in recognizing severe changes between Vscan focused cardiac ultrasound and comprehensive echocardiography. CONCLUSION: Pocket-size ultrasound imaging devices without continuous and pulse wave Doppler modalities can, even in the hands of a noncardiologist with limited cardiac ultrasound instructions with high sensitivity and specificity, be a useful tool for detecting more than mild aortic stenosis and more than mild mitral regurgitation. As such a focused cardiac ultrasound can be an extension of physical examinations for patients with newly discovered systolic murmur.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia/instrumentação , Programas de Rastreamento/instrumentação , Sopros Sistólicos/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sopros Sistólicos/etiologia
13.
Ann Cardiol Angeiol (Paris) ; 64(5): 352-61, 2015 Nov.
Artigo em Francês | MEDLINE | ID: mdl-26482624

RESUMO

UNLABELLED: The finding of a systolic heart murmur is common in medical military practice. Albeit often benign among young healthy adults, it can reveal a valvular or a cardiac disease, which could worsen during workout or expose to risk of a sudden death. This study aims to evaluate the diagnostic efficiency of the military general practitioner when discovering a systolic murmur among young asymptomatic patients. MATERIALS AND METHODS: During one year, this study involved all the general practitioners of the medical military centres of Brittany and the cardiologists of the military hospital in Brest. It prospectively enrolled a cohort of all military asymptomatic patients under 40, without any underlying known heart condition. Military general practitioners listed, thanks to an anonymous form, the main features of the systolic murmur and of the ECG and proposed an auscultatory diagnosis: innocent or organic murmur. Then cardiologists did the same and finally performed a transthoracic echocardiography giving the diagnosis. RESULTS: Fifty-eight patients were referred, 5 not meeting the inclusion criteria. Of the 53 patients included, military general practitioners found 46 innocent murmurs and 7 organic ones. Cardiologists found 51 innocent murmurs and 2 organic. Transthoracic echocardiography just took on one organic murmur (linked with a bicuspid aortic valve), spotted by the specialist, though judged innocent by the general practitioner. DISCUSSION: Most of innocent murmurs diagnosed by general practitioners (45/46) were confirmed. Regarding the seven organic murmurs, the main selected criteria (intensity over 3, orthostatic persistence, diffuse irradiation) are mostly in accordance with the literature, proving right medical instincts. Authors propose a practical management of systolic murmurs among asymptomatic young patients. CONCLUSION: Military general practitioners seem to master symptoms of organic murmur. This assessment argues for a promotion of a holistic clinical examination, which will help not only to rationalize the use of transthoracic echocardiography in economic terms but also to value the medical expertise.


Assuntos
Medicina Geral , Medicina Militar , Padrões de Prática Médica , Sopros Sistólicos/diagnóstico , Doenças Assintomáticas , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos , Registros , Adulto Jovem
16.
Recenti Prog Med ; 105(12): 469-72, 2014 Dec.
Artigo em Italiano | MEDLINE | ID: mdl-25533235

RESUMO

Cardiac auscultation permits to distinguish between the innocent heart murmurs and pathologic murmurs; characteristics of pathologic murmurs include a holosystolic or diastolic murmur, maximal murmur intensity at the upper left sternal border and increased intensity when the patient stands. Murmurs should be described by their timing in the cardiac cycle, intensity, shape, pitch, location, radiation, and response to dynamic maneuvers. When the medical history and physical examination support the diagnosis of innocent heart murmur, neither further investigation nor referal is indicated. On the contrary, echocardiography is recommended for patients with any other abnormal physical examination findings that increase the likelihood of structural heart disease. In this review we discuss the definition and classification of murmurs, how to evaluate it.


Assuntos
Auscultação Cardíaca/métodos , Sopros Cardíacos/diagnóstico , Sopros Sistólicos/diagnóstico , Criança , Ecocardiografia , Sopros Cardíacos/fisiopatologia , Humanos , Sopros Sistólicos/fisiopatologia
17.
PLoS One ; 9(11): e112673, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25393113

RESUMO

The future of quick and efficient disease diagnosis lays in the development of reliable non-invasive methods. As for the cardiac diseases - one of the major causes of death around the globe - a concept of an electronic stethoscope equipped with an automatic heart tone identification system appears to be the best solution. Thanks to the advancement in technology, the quality of phonocardiography signals is no longer an issue. However, appropriate algorithms for auto-diagnosis systems of heart diseases that could be capable of distinguishing most of known pathological states have not been yet developed. The main issue is non-stationary character of phonocardiography signals as well as a wide range of distinguishable pathological heart sounds. In this paper a new heart sound classification technique, which might find use in medical diagnostic systems, is presented. It is shown that by combining Linear Predictive Coding coefficients, used for future extraction, with a classifier built upon combining Support Vector Machine and Modified Cuckoo Search algorithm, an improvement in performance of the diagnostic system, in terms of accuracy, complexity and range of distinguishable heart sounds, can be made. The developed system achieved accuracy above 93% for all considered cases including simultaneous identification of twelve different heart sound classes. The respective system is compared with four different major classification methods, proving its reliability.


Assuntos
Ruídos Cardíacos/fisiologia , Coração/fisiopatologia , Processamento de Sinais Assistido por Computador , Máquina de Vetores de Suporte , Sopros Sistólicos/diagnóstico , Coração/fisiologia , Humanos , Fonocardiografia/instrumentação , Reprodutibilidade dos Testes , Sopros Sistólicos/fisiopatologia
18.
Artigo em Inglês | MEDLINE | ID: mdl-24110248

RESUMO

This paper describes a signal processing procedure that identifies the first and the second heart sounds (S1 and S2), extracts the systole from the diastole, detects and characterizes the systolic murmur found within. The identification of heart sounds was facilitated by discrete wavelet transform (DWT) approximation using the Coiflet wavelet and followed by using indicators that quantify signal activity and strength. The systole was isolated and divided into smaller short segments where the signal activity measure and absolute amplitude were computed. S1 and S2, and the onset and duration of a systolic murmur were marked. Using the indices derived from AR modeling, a systolic murmur can be characterized by its timing, duration, pitch, and shape either as crescendo, decrescendo, crescendo-decrescendo, or plateau. The performance of the proposed procedure was evaluated and proved with clinically recorded systolic murmur episodes.


Assuntos
Ruídos Cardíacos/fisiologia , Modelos Teóricos , Sopros Sistólicos/diagnóstico , Análise de Ondaletas , Automação , Diástole , Humanos , Processamento de Sinais Assistido por Computador , Sístole , Sopros Sistólicos/fisiopatologia
19.
Pediatr. aten. prim ; 15(58): 157-160, abr.-jun. 2013. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-113509

RESUMO

Continuamos con la serie de casos clínicos en Cardiología pediátrica, revisando los motivos de consulta y datos exploratorios frecuentes en las consultas de Pediatría de Atención Primaria, y presentados de forma breve y práctica. En este número se presenta el caso de un lactante de tres meses que acude por fatiga y sudoración con las tomas. Se discute cómo la exploración y los hallazgos electrocardiográficos orientan el manejo diagnóstico de este paciente (AU)


We continue the series of clinical cases in Pediatric Cardiology checking frequent reasons for consultation in the pediatric offices of Primary Care as well as exploratory signs, and presenting them in a brief and practical way. In this paper, we present the case of a 3 month-old infant who is taken because of shortness of breath and sweating with feeding. The way the physical exploration and the electrocardiographic findings guide the diagnosis of this patient is discussed (AU)


Assuntos
Humanos , Masculino , Lactente , Fadiga/complicações , Fadiga/diagnóstico , Fadiga/etiologia , Sopros Sistólicos/complicações , Sopros Sistólicos/diagnóstico , Sopros Sistólicos/etiologia , Eletrocardiografia/métodos , Eletrocardiografia , Ecocardiografia , Fadiga/fisiopatologia , Fadiga , Volume Sistólico/fisiologia , Volume Sistólico/efeitos da radiação , Sopros Sistólicos/fisiopatologia , Sopros Sistólicos , Atenção Primária à Saúde/métodos , Atenção Primária à Saúde/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...