Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.308
Filtrar
1.
A A Pract ; 18(6): e01790, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38785382

RESUMO

This case report describes the rare occurrence of a ventricular septal defect (VSD) after transcatheter aortic valve implantation (TAVI) in an 88-year-old male patient with aortic stenosis and other comorbidities. Initially asymptomatic, the patient was discharged but readmitted 2 weeks later with decompensated heart failure. Transesophageal echocardiography (TEE) revealed an increase in the size of the VSD and right ventricular dilation. Surgical intervention was chosen over percutaneous closure due to the patient's condition. A bovine pericardial patch was successfully used for repair. This case highlights the importance of vigilant post-TAVI monitoring and individualized treatment for TAVI-related complications.


Assuntos
Estenose da Valva Aórtica , Comunicação Interventricular , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Comunicação Interventricular/cirurgia , Estenose da Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana , Bovinos , Animais , Resultado do Tratamento
2.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726714

RESUMO

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Feminino , Masculino , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Desenho de Prótese , Hemodinâmica , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Mortalidade Hospitalar
3.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726720

RESUMO

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Assuntos
Consenso , Hemorragia , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Hemorragia/etiologia , Medição de Risco , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia
4.
EuroIntervention ; 20(9): 591-601, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726722

RESUMO

BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Eletrocardiografia Ambulatorial , Substituição da Valva Aórtica Transcateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Eletrocardiografia Ambulatorial/métodos , Fatores de Risco , Resultado do Tratamento
5.
Port J Card Thorac Vasc Surg ; 31(1): 12-16, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38743522

RESUMO

There has been a worldwide rapid adoption of transcatheter aortic valve replacement (TAVR) as an alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Currently, more TAVR explants with SAVRs are performed than TAVR-in TAV. TAVR explantation is a technically hazardous procedure mainly due to significant aortic neo-endothelialization which incorporates the TAVR valve. Surgical techniques for TAVR explantation are not well established and surgeon experience at present is limited. In this manuscript, we describe our technique for surgical explantation of transcatheter aortic bioprosthesis. Familiarity with the procedure and its clinical implications is essential for all cardiac surgeons.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Remoção de Dispositivo , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Remoção de Dispositivo/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação
6.
BMC Cardiovasc Disord ; 24(1): 253, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38750455

RESUMO

BACKGROUND: Primary coronary slow flow (CSF) is defined as delayed opacification of the distal epicardial vasculature during coronary angiography in the absence of relevant coronary artery stenoses. Microvascular disease is thought to be the underlying cause of this pathology. Epicardial fat tissue (EFT) is an active endocrine organ directly surrounding the coronary arteries that provides pro-inflammatory factors to the adjacent tissue by paracrine and vasocrine mechanisms. The aim of the present study was to investigate a potential association between EFT and primary CSF and whether EFT can predict the presence of primary CSF. METHODS: Between 2016 and 2017, n = 88 patients with high-grade aortic stenosis who were planned for transcatheter aortic valve implantation (TAVI) were included in this retrospective study. EFT volume was measured by pre-TAVI computed tomography (CT) using dedicated software. The presence of primary CSF was defined based on the TIMI frame count from the pre-TAVI coronary angiograms. RESULTS: Thirty-nine of 88 TAVI patients had CSF (44.3%). EFT volume was markedly higher in patients with CSF (142 ml [IQR 107-180] vs. 113 ml [IQR 89-147]; p = 0.009) and was strongly associated with the presence of CSF (OR 1.012 [95%CI 1.002-1.021]; p = 0.014). After adjustment, EFT volume was still an independent predictor of CSF (OR 1.016 [95%CI 1.004-1.026]; p = 0.009). CONCLUSION: Primary CSF was independently associated with increased EFT volume. Further studies are needed to validate this finding and elucidate whether a causal relationship exists.


Assuntos
Tecido Adiposo , Estenose da Valva Aórtica , Angiografia Coronária , Circulação Coronária , Pericárdio , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Masculino , Estudos Retrospectivos , Pericárdio/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/fisiopatologia , Idoso de 80 Anos ou mais , Fatores de Risco , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Angiografia por Tomografia Computadorizada , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Tecido Adiposo Epicárdico
7.
Sci Rep ; 14(1): 10902, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740898

RESUMO

Calcification of the aortic valve (CAVDS) is a major cause of aortic stenosis (AS) leading to loss of valve function which requires the substitution by surgical aortic valve replacement (SAVR) or transcatheter aortic valve intervention (TAVI). These procedures are associated with high post-intervention mortality, then the corresponding risk assessment is relevant from a clinical standpoint. This study compares the traditional Cox Proportional Hazard (CPH) against Machine Learning (ML) based methods, such as Deep Learning Survival (DeepSurv) and Random Survival Forest (RSF), to identify variables able to estimate the risk of death one year after the intervention, in patients undergoing either to SAVR or TAVI. We found that with all three approaches the combination of six variables, named albumin, age, BMI, glucose, hypertension, and clonal hemopoiesis of indeterminate potential (CHIP), allows for predicting mortality with a c-index of approximately 80 % . Importantly, we found that the ML models have a better prediction capability, making them as effective for statistical analysis in medicine as most state-of-the-art approaches, with the additional advantage that they may expose non-linear relationships. This study aims to improve the early identification of patients at higher risk of death, who could then benefit from a more appropriate therapeutic intervention.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Aprendizado Profundo , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/cirurgia , Calcinose/mortalidade , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Análise de Sobrevida , Fatores de Risco , Modelos de Riscos Proporcionais , Medição de Risco/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/métodos , Pessoa de Meia-Idade
8.
Clin Interv Aging ; 19: 695-703, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38711477

RESUMO

Purpose: In mixed aortic valve disease (MAVD), the results of transcatheter aortic valve replacement (TAVR) are conflicting. There is limited data on the outcomes of TAVR in patients with bicuspid aortic valve (BAV) and MAVD. The objective of this study is to compare outcomes after TAVR in BAV patients with MAVD and predominant aortic stenosis (PAS). Patients and Methods: Patients with BAV who underwent TAVR between January 2016 and April 2023 were included. The primary outcome was device success. The secondary endpoints were periprocedural mortality and other complications as defined by the Valve Academic Research Consortium-3 (VARC-3). Propensity score matching was used to minimize potential confounding. Results: A total of 262 patients were included in this study, 83 of whom had MAVD. The median age was 72 years, and 55.7% were male. The baseline comorbidity risk files were comparable between the two groups. Patients with MAVD had more mitral regurgitation, tricuspid regurgitation and pulmonary hypertension, larger annular and left ventricular outflow tract dimensions, and more severe calcification than PAS. In the unmatched population, MAVD patients had similar device success rate (69.9% vs 79.9%, P=0.075) and 30-day mortality (3.6% vs 3.4%, P=1) compared to PAS. Propensity score matching resulted in 66 patient pairs. Device success rate were still comparable in the matched population. Other clinical outcomes, including stroke, bleeding (type 2-4), major vascular complications, acute kidney injury (stage 2-4) and permanent pacemaker implantation, were comparable between the two groups. Multivariable logistic regression analysis did not show MAVD to be an independent negative predictor of device success. At one year, survival was similar between patients with MAVD and those with PAS. Conclusion: For the bicuspid valve, patients with MAVD had a more challenging anatomy. MAVD patients associated with comparable 30-day clinical outcomes after TAVR compared to PAS patients in patients with BAV.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Complicações Pós-Operatórias , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estenose da Valva Aórtica/cirurgia , Idoso , Doença da Válvula Aórtica Bicúspide/cirurgia , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Pessoa de Meia-Idade , Fatores de Risco , Doenças das Valvas Cardíacas/cirurgia
9.
Sci Rep ; 14(1): 10409, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710782

RESUMO

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Substituição da Valva Aórtica Transcateter/métodos , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X , Aorta/diagnóstico por imagem , Aorta/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas , Estudos Retrospectivos
12.
J Am Heart Assoc ; 13(10): e033601, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38761069

RESUMO

BACKGROUND: The aims of this study were to understand the incidence and outcomes of patients with cardiogenic shock (CS) due to severe aortic stenosis (AS), and the impact of conventional treatment strategies in this population. METHODS AND RESULTS: All patients admitted to the Cleveland Clinic cardiac intensive care unit between January 1, 2010 and December 31, 2021 with CS were retrospectively identified and categorized into those with CS in the setting of severe AS versus CS without AS. The impact of various treatment strategies on mortality was further assessed. We identified 2754 patients with CS during the study period, of whom 216 patients (8%) had CS in the setting of severe AS. Medical management was associated with the highest 30-day mortality when compared with either balloon aortic valve replacement or aortic valve replacement (surgical or transcatheter aortic valve replacement) (hazard ratio, 3.69 [95% CI, 2.04-6.66]; P<0.0001). Among patients who received transcatheter therapy, 30-day mortality was significantly higher in patients who received balloon aortic valvuloplasty versus transcatheter aortic valve replacement (26% versus 4%, P=0.02). Both surgical and transcatheter aortic valve replacement had considerably lower mortality than medical management and balloon aortic valvuloplasty at 30 days and 1 year (P<0.05 for both comparisons). CONCLUSIONS: CS due to severe AS is associated with high in-hospital and 30-day mortality, worse compared with those with CS without AS. In suitable patients, urgent surgical aortic valvuloplasty or transcatheter aortic valve replacement is associated with favorable short- and long-term outcomes. Although balloon aortic valvuloplasty may be used to temporize patients with CS in the setting of severe AS, mortality is ≈50% if not followed by definitive aortic valve replacement within 90 days.


Assuntos
Estenose da Valva Aórtica , Índice de Gravidade de Doença , Choque Cardiogênico , Substituição da Valva Aórtica Transcateter , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Valvuloplastia com Balão/mortalidade , Valvuloplastia com Balão/efeitos adversos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Risco , Fatores de Tempo , Incidência
13.
Circ Cardiovasc Imaging ; 17(5): e015996, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771906

RESUMO

BACKGROUND: Extracellular volume fraction (ECV) is a marker for myocardial fibrosis and infiltration, can be quantified using cardiac computed tomography (ECVCT), and has prognostic utility in several diseases. This study aims to map out regional differences in ECVCT to obtain greater insights into the pathophysiological mechanisms of ECV expansion and its clinical implications. METHODS: Three prospective cohorts were included: patients with aortic stenosis (AS) and coexisting AS and transthyretin cardiac amyloidosis were referred for a transcatheter aortic valve replacement and had ECG-gated CT angiography and Technetium-99m-labelled 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy to differentiate between the 2 cohorts. Controls had CT angiography and cardiac magnetic resonance demonstrating no significant coronary artery disease or infarction. Global and regional ECVCT was analyzed, and its association with mortality was assessed for patients with AS. RESULTS: In 199 patients, controls (n=65; 66% male), AS (n=115), and coexisting AS and transthyretin cardiac amyloidosis (n=19) had a global ECVCT of 26.1 (25.0-27.8%) versus 29.1 (27.5-31.1%) versus 37.4 (32.5-46.6%), respectively; P<0.001. Across cohorts, ECVCT was higher at the base (versus apex), the inferoseptum (versus anterolateral wall), and the subendocardium (versus subepicardium); P<0.05 for all. Among patients with AS, epicardial ECVCT, rather than any other regional value or global ECVCT, was the strongest predictor of mortality at a median of 3.9 (max 6.3) years (adjusted hazard ratio, 1.21 [95% CI, 1.08-1.36]; P=0.002). CONCLUSIONS: Regional differences in ECVCT suggest a predilection for fibrosis and amyloid infiltration at the base, subendocardium, inferior wall, and septum more than the anterior and lateral myocardium. ECVCT can predict long-term mortality with the subepicardium demonstrating the strongest discriminatory power. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT03029026 and NCT03094143.


Assuntos
Neuropatias Amiloides Familiares , Estenose da Valva Aórtica , Angiografia por Tomografia Computadorizada , Fibrose , Miocárdio , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Idoso , Estudos Prospectivos , Angiografia por Tomografia Computadorizada/métodos , Idoso de 80 Anos ou mais , Miocárdio/patologia , Neuropatias Amiloides Familiares/diagnóstico por imagem , Neuropatias Amiloides Familiares/complicações , Neuropatias Amiloides Familiares/mortalidade , Valor Preditivo dos Testes , Prognóstico , Angiografia Coronária/métodos , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Pessoa de Meia-Idade
14.
Sci Rep ; 14(1): 11762, 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38783030

RESUMO

There is limited data on the effect of socioeconomic status (SES) on transcatheter (TAVR) and surgical aortic valve replacement (SAVR) outcomes for aortic stenosis (AS). This study conducted a population-based analysis to assess the influence of SES on valve replacement outcomes. Patients with AS undergoing TAVR or SAVR were identified in National Inpatient Sample from Q4 2015-2020. Multivariable logistic regressions were used to compare in-hospital outcomes between patients living in neighborhoods of income at the lowest and highest quartiles. Of 613,785 AS patients, 9.77% underwent TAVR and 10.13% had SAVR. These rates decline with lower neighborhood income levels, with TAVR/SAVR ratio also declining in lower-income areas. Excluding concomitant procedures, 58,064 patients received isolated TAVR (12,355 low-income and 15,212 high-income) and 43,694 underwent isolated SAVR (10,029 low-income and 10,811 high-income). Low-income patients, in both TAVR and SAVR, were younger but had more comorbid burden. For isolated TAVR, outcomes were similar across income groups. However, for isolated SAVR, low-income patients experienced higher in-hospital mortality (aOR = 1.44, p < 0.01), pulmonary (aOR = 1.13, p = 0.01), and renal complications (aOR = 1.14, p < 0.01). They also had more transfers, longer waits for operations, and extended hospital stays. Lower-income communities had reduced access to TAVR and SAVR, with TAVR accessibility being particularly limited. When given access to TAVR, patients from lower-income neighborhoods had mostly comparable outcomes. However, patients from low-income communities faced worse outcomes in SAVR, possibly due to delays in treatment. Ensuring equitable specialized healthcare resources including expanding TAVR access in economically disadvantaged communities is crucial.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Disparidades em Assistência à Saúde , Pacientes Internados/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca , Estados Unidos/epidemiologia , Mortalidade Hospitalar , Pessoa de Meia-Idade , Fatores Socioeconômicos , Classe Social , Valva Aórtica/cirurgia , Resultado do Tratamento , Disparidades Socioeconômicas em Saúde
15.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38691562

RESUMO

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Septo Interventricular , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Septo Interventricular/diagnóstico por imagem , Idoso de 80 Anos ou mais , Fatores de Risco , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Resultado do Tratamento , Valor Preditivo dos Testes , Medição de Risco , Índice de Gravidade de Doença , Estudos Retrospectivos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Tomografia Computadorizada por Raios X , Potenciais de Ação
16.
Curr Probl Cardiol ; 49(7): 102629, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38723797

RESUMO

Transcatheter aortic valve implantation (TAVI) is a promising treatment strategy for high-risk surgical patients, and trials investigating its effectiveness in intermediate- and lower-risk patients are underway. Data are inconsistent regarding the superiority of using local anesthesia with conscious sedation alone versus general anesthesia (GA) as the anesthesia management of choice for elderly frail patients. Historically, TAVI procedure is performed under GA with transesophageal echocardiography. This approach gives operators stable hemodynamic control of the patient and helps decrease the risk of many of the operation's documented complications, including paravalvular leak and valve malpositioning. However, some studies have criticized the dependence of GA on mechanical ventilation and an increased need for catecholamine and/or vasopressor agents. Alternatively, to further capitalize on the minimally invasive nature of TAVI, some authors have advocated for the use of local anesthesia (LA) and/or conscious sedation approach, which would decrease procedure time, length of hospital stay, and minimize the need for postoperative inotropes. Ultimately and at present, the choice of anesthesia is based on the personal experience and preference of the Heart Team involved in the TAVI procedure, which will dictate the best possible management plan for each patient. Many patients currently undergoing TAVI are elderly and have multiple comorbidities, making their care complex. Anesthetic care is shifting from GA to sedation and regional block, but life-threatening complications are still relatively common and safety during planning and conduct of these procedures by the heart team, with the anesthesiologist at the center, is paramount.


Assuntos
Anestesia Geral , Anestesia Local , Estenose da Valva Aórtica , Ensaios Clínicos Controlados Aleatórios como Assunto , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Anestesia Geral/métodos , Anestesia Local/métodos , Estenose da Valva Aórtica/cirurgia , Pontuação de Propensão
17.
J Am Heart Assoc ; 13(10): e034401, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38761080

RESUMO

BACKGROUND: Coronary pressure indices to assess coronary artery disease are currently underused in patients with aortic stenosis due to many potential physiological effects that might hinder their interpretation. Studies with varying sample sizes have provided us with conflicting results on the effect of transcatheter aortic valve replacement (TAVR) on these indices. The aim of this meta-analysis was to study immediate and long-term effects of TAVR on fractional flow reserve (FFR) and nonhyperemic pressure ratios (NHPRs). METHODS AND RESULTS: Lesion-specific coronary pressure data were extracted from 6 studies, resulting in 147 lesions for immediate change in FFR analysis and 105 for NHPR analysis. To investigate the long-term changes, 93 lesions for FFR analysis and 68 for NHPR analysis were found. Lesion data were pooled and compared with paired t tests. Immediately after TAVR, FFR decreased significantly (-0.0130±0.0406 SD, P: 0.0002) while NHPR remained stable (0.0003±0.0675, P: 0.9675). Long-term after TAVR, FFR decreased significantly (-0.0230±0.0747, P: 0.0038) while NHPR increased nonsignificantly (0.0166±0.0699, P: 0.0543). When only borderline NHPR lesions were considered, this increase became significant (0.0249±0.0441, P: 0.0015). Sensitivity analysis confirmed our results in borderline lesions. CONCLUSIONS: TAVR resulted in small significant, but opposite, changes in FFR and NHPR. Using the standard cut-offs in patients with severe aortic stenosis, FFR might underestimate the physiological significance of a coronary lesion while NHPRs might overestimate its significance. The described changes only play a clinically relevant role in borderline lesions. Therefore, even in patients with aortic stenosis, an overtly positive or negative physiological assessment can be trusted.


Assuntos
Estenose da Valva Aórtica , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/complicações , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Hiperemia/fisiopatologia , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 17(10): 1252-1264, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38811107

RESUMO

BACKGROUND: Cardiac damage caused by aortic stenosis (AS) can be categorized into stages, which are associated with a progressively increasing risk of death after transcatheter aortic valve replacement (TAVR). OBJECTIVES: The authors investigated sex-related differences in cardiac damage among patients with symptomatic AS and the prognostic value of cardiac damage classification in women and men undergoing TAVR. METHODS: In a prospective registry, pre-TAVR echocardiograms were used to categorize patients into 5 stages of cardiac damage caused by AS. Differences in the extent of cardiac damage were compared according to sex, and its implications on clinical outcomes after TAVR were explored. RESULTS: Among 2,026 patients undergoing TAVR between August 2007 and June 2022 (995 [49.1%] women and 1,031 [50.9%] men), we observed sex-specific differences in the pattern of cardiac damage (women vs men; stage 0: 2.6% vs 3.1%, stage 1: 13.4% vs 10.1%, stage 2: 37.1% vs 39.5%, stage 3: 27.5% vs 15.6%, and stage 4: 19.4% vs 31.7%). There was a stepwise increase in 5-year all-cause mortality according to stage in women (HRadjusted: 1.43; 95% CI: 1.28-1.60, for linear trend) and men (HRadjusted: 1.26; 95% CI: 1.14-1.38, for linear trend). Female sex was associated with a lower 5-year mortality in early stages (stage 0, 1, or 2) but not in advanced stages (stage 3 or 4). CONCLUSIONS: The pattern of cardiac damage secondary to AS differed by sex. In early stages of cardiac damage, women had a lower 5-year mortality than men, whereas in more advanced stages, mortality was comparable between sexes. (SwissTAVI Registry; NCT01368250).


Assuntos
Estenose da Valva Aórtica , Disparidades nos Níveis de Saúde , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Fatores Sexuais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Fatores de Risco , Idoso de 80 Anos ou mais , Medição de Risco , Fatores de Tempo , Resultado do Tratamento , Estudos Prospectivos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...