Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.017
Filtrar
1.
J Appl Oral Sci ; 32: e20230439, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38896638

RESUMO

OBJECTIVE: To evaluate the effect of the labiolingual diameter and construction of an endodontically treated (ET) anterior tooth with crown restoration on stress distribution and biomechanical safety under occlusal loading. METHODOLOGY: Three-dimensional finite element models were generated for maxillary central incisors with all-ceramic crown restorations. The labiolingual diameters of the tooth, defined as the horizontal distance between the protrusion of the labial and lingual surfaces, were changed as follows: (D1) 6.85 mm, (D2) 6.35 mm, and (D3) 5.85 mm. The model was constructed as follows: (S0) vital pulp tooth; (S1) ET tooth; (S2) ET tooth with a 2 mm ferrule, restored with a fiber post and composite resin core; (S3) ET tooth without a ferrule, restored with a fiber post and composite resin core. A total of 12 models were developed. In total, two force loads (100 N) were applied to the crown's incisal edge and palatal surface at a 45° oblique angle to the longitudinal axis of the teeth. The Von Mises stress distribution and maximum stress of the models were analyzed. RESULTS: Regardless of the loading location, stress concentration and maximum stress (34.07~66.78MPa) in all models occurred in the labial cervical 1/3 of each root. Both labiolingual diameter and construction influenced the maximum stress of the residual tooth tissue, with the impact of the labiolingual diameter being greater. A reduction in labiolingual diameter led to increased maximum stress throughout the tooth. The ferrule reduced the maximum stress of the core of S2 models (7.15~10.69 MPa), which is lower compared with that of S3 models (19.45~43.67 MPa). CONCLUSION: The labiolingual diameter exerts a greater impact on the biomechanical characteristics of ET anterior teeth with crown restoration, surpassing the influence of the construction. The ferrule can reduce the maximum stress of the core and maintain the uniformity of stress distribution.


Assuntos
Resinas Compostas , Coroas , Análise do Estresse Dentário , Análise de Elementos Finitos , Incisivo , Dente não Vital , Dente não Vital/fisiopatologia , Humanos , Fenômenos Biomecânicos , Incisivo/anatomia & histologia , Incisivo/fisiologia , Resinas Compostas/química , Análise do Estresse Dentário/métodos , Técnica para Retentor Intrarradicular , Reprodutibilidade dos Testes , Estresse Mecânico , Valores de Referência , Força de Mordida , Imageamento Tridimensional/métodos , Planejamento de Prótese Dentária , Teste de Materiais , Coroa do Dente/anatomia & histologia , Coroa do Dente/fisiologia
2.
Prim Dent J ; 13(2): 53-57, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38888075

RESUMO

A technique is outlined for utilising a polymeric composite reinforced with glass fibres in a three-dimensional mesh as a post-core in aesthetic cases. The clinical procedure involves obtaining an impression of the root canal space, scanning the definitive cast, and milling a fibre-reinforced composite post-core. Subsequently, the intra-radicular post-core is cemented using an adhesive resin cement. The use of custom-made computer-aided design-computer-aided manufacturing (CAD-CAM) fibre-reinforced composite post-core facilitates repairability, provides better adaptation to the root canal space, avoids uneven cement thickness, ensures chemical adhesion to resin cement, and promotes favourable aesthetics when combined with all-ceramic crowns.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Vidro , Técnica para Retentor Intrarradicular , Humanos , Resinas Compostas/química , Vidro/química , Cimentos de Resina/química , Coroas , Estética Dentária , Retenção em Prótese Dentária , Materiais Dentários/química , Cimentação
3.
Clin Oral Investig ; 28(7): 386, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38890207

RESUMO

OBJECTIVE: This study aimed to evaluate the effect of ultrasonic activation of etch-and-rinse and self-etch adhesive systems on the bond strength of resin cement to irradiated root dentin. MATERIALS AND METHODS: Eighty human maxillary anterior teeth were distributed into 8 groups (n = 10), according to the type of adhesive system used (etch-and-rinse and self-etch), the ultrasonic activation of the adhesive systems, and the dentin condition (irradiated or non-irradiated - 70 Gy). Endodontic treatment was performed followed by fiberglass post-space preparation. After fiberglass posts' luting, the roots were transversely sectioned on dentin discs and submitted to the push-out bond strength test (0.5 mm/min). The fractured specimens were analyzed under a stereomicroscope and Scanning Electron Microscope (SEM) for failure mode classification. One of the dentin discs was analyzed under SEM to evaluate the characteristics of the adhesive interface. RESULTS: Irradiated specimens had lower bond strength than non-irradiated specimens (P < 0.0001). Ultrasonic activation of both adhesive systems increased the bond strength of the resin cement to irradiated dentin (P < 0.0001). Radiotherapy significantly affected the failure mode in the middle (P = 0.024) and apical thirds (P = 0.032) (adhesive failure). CONCLUSION: Non-irradiated specimens had a more homogeneous adhesive interface. When ultrasonically activated, both adhesive systems showed a greater number of resinous tags, regardless of the dentin condition. CLINICAL RELEVANCE: Ultrasonic activation of adhesive systems is a feasible strategy to enhance fiberglass posts retention in oncological patients.


Assuntos
Colagem Dentária , Dentina , Teste de Materiais , Microscopia Eletrônica de Varredura , Técnica para Retentor Intrarradicular , Cimentos de Resina , Humanos , Cimentos de Resina/química , Colagem Dentária/métodos , Dentina/efeitos da radiação , Técnicas In Vitro , Adesivos Dentinários/química , Análise do Estresse Dentário , Propriedades de Superfície , Raiz Dentária/efeitos da radiação , Ultrassom , Condicionamento Ácido do Dente , Incisivo , Vidro/química
4.
BMC Oral Health ; 24(1): 696, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38879492

RESUMO

BACKGROUND: An optimum restoration for reconstructing endodontically treated teeth should provide excellent marginal adaptation, high fracture resistance as well as maximum tooth structure conservation. The purpose of this study was to evaluate the marginal adaptation and fatigue resistance of different coronal restorations in endodontically treated premolars. METHODS: Thirty sound maxillary first premolars were endodontically treated and received MOD cavities. Teeth were randomly allocated into three groups (n = 10) according to the type of coronal restoration: Group R: polyethylene fibers (ribbond), fibers-reinforced composite (everX posterior) and final layer of nano-hybrid composite. Group O: indirect lithium disilicate overlay and Group C: fiber-post, resin composite restoration, and lithium disilicate crown. Marginal gap assessment was performed before and after thermocycling (5000 cycles) using stereomicroscope. Samples were subjected to stepwise-stress loading starting at 200 N, and increased by 100 N in each step until failure occurred. Statistical analysis was done by One-way ANOVA followed Tukey`s Post Hoc test for multiple comparison. Paired t test was used to compare the marginal adaptation before and after thermocycling. Survival probability was evaluated by Life table survival analysis. Failure mode analysis was performed with Chi-square test. RESULTS: Marginal gap was significantly the lowest in group R (37.49 ± 5.05) and (42.68 ± 2.38), while being the highest in group C (59.78 ± 5.67) and (71.52 ± 5.18) in before and after thermocycling respectively (P < 0.0001). Fatigue resistance was the highest for group O (1310.8 ± 196.7), and the lowest for group R (905.4 ± 170.51) with a significant difference between groups (P < 0.0001). Crown group had the highest percentage (80%) of catastrophic failure, while, overlay group exhibited the lowest (20%). CONCLUSIONS: Direct restoration without cuspal coverage using ribbon fibers with short FRC provided better marginal adaptation than indirect overlays and crowns, but fatigue resistance wasn't significantly improved. Adhesive ceramic overlays showed the best fatigue performance and the least catastrophic failure rate compared to both direct fiber-reinforced composite and indirect ceramic full coverage restorations. CLINICAL SIGNIFICANCE: Indirect adhesive overlays are a suitable, more conservative restorative option for endodontically treated teeth than full coverage restorations, especially when tooth structure is severely compromised.


Assuntos
Dente Pré-Molar , Resinas Compostas , Coroas , Adaptação Marginal Dentária , Técnica para Retentor Intrarradicular , Dente não Vital , Humanos , Resinas Compostas/química , Técnicas In Vitro , Restauração Dentária Permanente/métodos , Porcelana Dentária/química , Análise do Estresse Dentário , Polietilenos/química , Falha de Restauração Dentária , Teste de Materiais , Materiais Dentários/química
5.
J Dent ; 146: 105068, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38740250

RESUMO

OBJECTIVE: The purpose of this systematic review was to assess the impact of the incomplete ferrule on the fracture of endodontically treated teeth (ETT). DATA: The keywords such as "incomplete ferrule," "ferrule," "ferrule effect," "residual dentin," "remaining dentin," or "remaining coronal dentin" were used for searching, and only in vitro studies investigating the incomplete ferrule effect on natural teeth were included. SOURCES: PubMed, Medline, Embase, Cochrane Library, and Science Direct databases, and manual-searching. STUDY SELECTION: The search strategy yielded 1633 hits, and a total of 19 in vitro studies closely related to the effect of incomplete ferrule on ETT were included. CONCLUSION: The presence of an incomplete ferrule may significantly increase the fracture resistance of restored ETT, compared with restored ETT without ferrule. The number of residual axial walls of the incomplete ferrule may have an impact on the fracture resistance and fracture mode. The location of residual axial walls of the incomplete ferrule may affect the fracture resistance but not the fracture mode. CLINICAL IMPLICATIONS: Limited data suggest that the presence of incomplete ferrule has a positive effect on the fracture resistance of restored ETT. An incomplete ferrule can be an alternative for restoring ETT when a complete ferrule is not present. Nevertheless, further high-quality studies are still needed to offer more robust evidence and to take potential confounding factors into account.


Assuntos
Fraturas dos Dentes , Dente não Vital , Humanos , Dentina/lesões , Técnicas In Vitro , Técnica para Retentor Intrarradicular , Análise do Estresse Dentário
6.
BMC Oral Health ; 24(1): 523, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702708

RESUMO

BACKGROUND: The rising demand for improved aesthetics has driven the utilization of recently introduced aesthetic materials for creating custom post and core restorations. However, information regarding the fracture resistance of these materials remains unclear, which limits their practical use as custom post and core restorations in clinical applications. AIM OF THE STUDY: This study aimed to evaluate the fracture resistance of three non-metallic esthetic post and core restorations and their modes of failure. MATERIALS AND METHODS: Thirty-nine single-rooted human maxillary central incisors were endodontically treated. A standardized post space preparation of 9mm length was performed to all teeth to receive custom-made post and core restorations. The prepared teeth were randomly allocated to receive a post and core restoration made of one of the following materials (n=13): glass fiber-reinforced composite (FRC), polyetheretherketone (PEEK) and polymer-infiltrated ceramic-network (PICN). An intraoral scanner was used to scan all teeth including the post spaces. Computer-aided design and computer-aided manufacturing (CAD-CAM) was used to fabricate post and core restorations. Post and core restorations were cemented using self-adhesive resin cement. All specimens were subjected to fracture resistance testing using a universal testing machine. Failure mode analysis was assessed using a stereomicroscope and SEM. The data was statistically analyzed using One-Way ANOVA test followed by multiple pairwise comparisons using Bonferroni adjusted significance level. RESULTS: Custom PEEK post and core restorations displayed the least fracture load values at 286.16 ± 67.09 N. In contrast, FRC exhibited the highest average fracture load at 452.60 ± 105.90 N, closely followed by PICN at 426.76 ± 77.99 N. In terms of failure modes, 46.2% of specimens with PICN were deemed non-restorable, while for PEEK and FRC, these percentages were 58.8% and 61.5%, respectively. CONCLUSIONS: Within the limitation of this study, both FRC and PICN demonstrated good performance regarding fracture resistance, surpassing that of PEEK.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Falha de Restauração Dentária , Estética Dentária , Técnica para Retentor Intrarradicular , Humanos , Cerâmica , Análise do Estresse Dentário , Benzofenonas , Incisivo/lesões , Materiais Dentários/química , Polietilenoglicóis , Cetonas/química , Polímeros , Vidro , Teste de Materiais , Planejamento de Prótese Dentária
7.
Clin Exp Dent Res ; 10(3): e881, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38798057

RESUMO

BACKGROUND: In conjunction with post placement in root-filled teeth with periapical healthy conditions, root canal retreatment may be performed to improve the seal of the root canal. Whether root canal retreatment for technical reasons (retreatments in teeth without apical periodontitis (AP)) results in lower frequency of AP is unknown. OBJECTIVE: To examine whether there is a difference in frequency of AP between roots with root canals retreated for technical reasons, and roots with root canals not retreated before post placement, with a minimum follow-up of 5 years. Also, to examine changes in root filling quality following root canal retreatment for technical reasons. METHODS: This retrospective study included radiographs of 441 root-filled roots without periapical radiolucencies at baseline, scheduled for post and core treatment. Follow-up data for a minimum of 5 years were available for 305 roots (loss to follow-up 30.8%), 46 of which were retreated for technical reasons. Two calibrated observers assessed root filling sealing quality and length, respectively, and periapical status according to the Periapical Index. The main outcome of the study, AP, was used as the dependent variable and all analyses were performed at root level. RESULTS: The overall frequency of AP at follow-up was 13.8%. The difference in frequency of AP between retreated (4.3%) and nonretreated (15.4%) root canals was not statistically significant, p = .061. Analyses including only roots with preoperatively inadequate root filling quality showed a statistically significant difference (p = .017) between the two treatment groups (2.4% vs. 22.9%). CONCLUSIONS: Root canal retreatment for technical reasons before post and core placement significantly reduces the frequency of AP in roots with inadequate root filling quality.


Assuntos
Periodontite Periapical , Técnica para Retentor Intrarradicular , Humanos , Estudos Retrospectivos , Periodontite Periapical/terapia , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Tratamento do Canal Radicular/métodos , Tratamento do Canal Radicular/estatística & dados numéricos , Tratamento do Canal Radicular/efeitos adversos , Retratamento/estatística & dados numéricos , Idoso , Seguimentos
8.
Medicina (Kaunas) ; 60(5)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38792931

RESUMO

The primary objective of this study is to conduct a comprehensive review of the existing literature that discusses research on post and core restorations, covering aspects such as their composition, manufacturing methods, and clinical effectiveness. The methodology employed in this review encompasses the implementation of a well-defined search strategy, the establishment of criteria for inclusion and exclusion, and the selection of relevant studies to summarize their findings. To gather relevant literature published between 1993 and 2023, the research team conducted separate searches on PubMed, Web of Science, and Embase databases. In total, 168 titles were initially retrieved from these electronic databases. By applying the predefined exclusion criteria, the researchers identified 73 articles that specifically address the conventional and computer-aided design/computer-aided manufacturing (CAD/CAM) technologies employed in post and core restorations. These treatments are commonly employed to restore teeth that have received endodontic therapy and subsequently experienced loss of dental structure. The development of computerized technology for the creation of customized posts and cores has emerged as a straightforward and efficient alternative to traditional methods. The review synthesizes papers discussing the techniques and materials involved in CAD/CAM-based construction of post and cores. It explores strategies for restoring endodontically treated teeth, highlighting both direct and indirect approaches. Commonly mentioned materials include zirconia, composite resin, and hybrid ceramics. Despite the limited literature on CAD/CAM post and core procedures, the review emphasizes the necessity of further research to assess long-term outcomes and efficacy. Additionally, it suggests including implications for future research and clinical recommendations to enhance the depth and practical relevance of the review.


Assuntos
Desenho Assistido por Computador , Humanos , Técnica para Retentor Intrarradicular , Planejamento de Prótese Dentária/métodos , Restauração Dentária Permanente/métodos
9.
Clin Oral Investig ; 28(6): 316, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38750289

RESUMO

OBJECTIVE: This study aimed to evaluate the fracture strength of teeth restored using fiber-reinforced direct restorative materials after endodontic treatment with a conservative mesio-occlusal access cavity design. MATERIALS AND METHODS: A total of 100 extracted intact mandibular first molars were selected and distributed into a positive control group where teeth left intact and the following four test groups comprised of teeth with conservative mesio-occlusal access cavities that had undergone root canal treatment (n = 20/group): access cavity without restoration (negative control), bulk-fill resin composite with horizontal glass fiber post reinforcement, fiber-reinforced composite with bulk-fill resin and bulk-fill resin composite. Following thermocycling (10,000 cycles), fracture resistance was measured using a universal testing machine. Statistical analyses (one-way analysis of variance and the Tamhane test) were performed, and statistical significance was set at p < 0.05. RESULTS: Groups with minimally invasive access cavities had lower fracture strength than intact teeth, regardless of the restoration material (p < 0.05). Fiber-reinforced composite groups demonstrated higher fracture strength than bulk-fill resin composite alone (p < 0.05). Fracture types varied among groups, with restorable fractures predominant in the fiber-reinforced composite groups. CONCLUSION: This study suggests that using fiber-reinforced composite materials, especially in combination with bulk-fill resin composites, can effectively enhance the fracture strength of endodontically treated teeth with conservative access cavities. However, using only bulk-fill resin composite is not recommended based on the fracture strength results. CLINICAL SIGNIFICANCE: When teeth that undergo endodontic treatment are restored using a conservative access cavity design and fiber-reinforced composite materials, especially in combination with bulk-fill resin composites, the fracture strength of the teeth can be effectively increased.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Análise do Estresse Dentário , Dente Molar , Fraturas dos Dentes , Dente não Vital , Resinas Compostas/química , Humanos , Dente não Vital/terapia , Fraturas dos Dentes/terapia , Restauração Dentária Permanente/métodos , Técnicas In Vitro , Mandíbula , Teste de Materiais , Vidro/química , Técnica para Retentor Intrarradicular , Preparo da Cavidade Dentária/métodos , Materiais Dentários/química , Tratamento do Canal Radicular/métodos
10.
Int J Prosthodont ; 37(7): 253-263, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38787590

RESUMO

PURPOSE: This study investigated the impact of common surface pretreatments on the contact angle (CA), surface free energy (SFE), and push-out bond strength (PBS) of custom 3D-printed resin posts. MATERIALS AND METHODS: Post spaces of 60 endodontically treated mandibular premolars were prepared. Custom 3D-printed posts made from permanent crown resin were fabricated for 50 randomly selected post spaces. The specimens were then divided into six groups (n = 10) based on their surface pretreatment methods. These methods included sandblasting (SB), silane (SL), hydrofluoric acid (HF), and hydrogen peroxide (HP). Additionally, two control groups were established: glass fiber control (GFC) and permanent resin control (PRC). CA and SFE were measured for each 3D-printed post group. PBS and failure mode analyses were conducted. The data were analyzed using the two-way ANOVA followed by the Tukey post hoc test (α = .05). RESULTS: The lowest CA values were found in the SB and SL groups. The SB group had the highest SFE compared to all other groups. SL markedly enhanced the PBS of the resin post compared to the PRC at the cervical, middle, and apical levels (P = .001, P = .000, and P = .002, respectively), and the values were comparable to those of the GFC (P = .695, P = .999, and P = .992, respectively). Except in the GFC, SB, and SL groups, mixed failure decreased from the cervical to apical levels, while adhesive failure rates increased. CONCLUSIONS: The application of silane and sandblasting to the surfaces of custom 3D-printed resin posts effectively increased their SFE, thereby enhancing their adhesion.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Impressão Tridimensional , Propriedades de Superfície , Humanos , Técnicas In Vitro , Análise do Estresse Dentário , Dente Pré-Molar , Teste de Materiais , Dente não Vital
11.
Braz Dent J ; 35: e245720, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775593

RESUMO

This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Assuntos
Dentina , Técnica para Retentor Intrarradicular , Cimentos de Resina , Bovinos , Animais , Cimentos de Resina/química , Colagem Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Adesivos Dentinários/química , Microscopia Confocal , Ácidos Polimetacrílicos/química , Teste de Materiais , Vidro/química , Raiz Dentária , Polietilenoglicóis/química , Análise do Estresse Dentário
12.
Photodiagnosis Photodyn Ther ; 47: 104076, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38582390

RESUMO

AIMS: Impact of different post-space disinfectants (Saline, Sodium hypochlorite (NaOCl) followed by ethylene-diamine-tetra-acetic acid (EDTA) and curcumin activated by microbubble emulsion (MBE) on the Vickers hardness (VH) of root canal dentin and extrusion bond strength (EBS) of Glass fiber post (GFP) and PEEK post. METHODS: Ninety maxillary central incisors having fully formed roots were included. After the specimen's disinfection, root canal treatment was completed. Post space was prepared by removing gutta-percha using gates glidden drills. Teeth were then arbitrarily allocated into three groups based on the methods of disinfection regime used. Group 1: Saline, Group 2: NaOCl+ EDTA and Group 3: Curcumin activated by MBE (n = 30). Analysis of VH of radicular dentin was performed using a micro-Vickers tester on ten samples from each group. After post-space disinfection, twenty specimens from each group were further divided into two subgroups (n = 10) In group-1A 2A, and 3A, GFP was used. Whereas, prefabricated PEEK posts were used in 1B, 2B, and 3B subgroups. The PBS and failure modes were performed using a universal testing machine and stereomicroscope respectively. Data was analyzed using ANOVA and Tukey post hoc test to identify significant variations among groups concerning the MH and EBS of the different posts used (p = 0.05). RESULTS: Group 2 (5.25 % NaOCl + 17 % EDTA) (0.15 ± 0.02 GPa) treated specimens presented lowest scores of VH. However, Group 1 (Saline) irrigated canals displayed the highest scores of surface hardness (0.25 ± 0.07 GPa). Additionally, a cervical third of 3A (CP activated by MBE + GFP) (11.22 ± 0.79 MPa) presented the highest scores of bond integrity. Whereas Group 1B (Saline + PEEK post) treated specimens presented the lowest scores of PBS (4.15 ± 0.15 MPa). CONCLUSION: Curcumin activated by microbubble emulsion for disinfection of canal dentin demonstrated favorable VH. Similarly, glass fiber post-cemented in radicular walls disinfected with curcumin activated with MBE showed promising post-bond integrity to the canal dentin.


Assuntos
Benzofenonas , Curcumina , Ácido Edético , Vidro , Polietilenoglicóis , Polímeros , Hipoclorito de Sódio , Humanos , Polietilenoglicóis/química , Ácido Edético/farmacologia , Polímeros/química , Curcumina/farmacologia , Hipoclorito de Sódio/farmacologia , Fármacos Fotossensibilizantes/farmacologia , Técnica para Retentor Intrarradicular , Emulsões , Dureza , Teste de Materiais , Colagem Dentária/métodos , Desinfecção/métodos
13.
BMC Oral Health ; 24(1): 497, 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38678244

RESUMO

BACKGROUND: This study aimed to assess the accuracy of two different endodontic guides for fiber post removal. METHODS: In this in vitro study, 54 maxillary canine fiber posts were mounted on 36 maxillary stone casts; 18 teeth were mounted unilaterally, and 36 teeth were mounted bilaterally. Static endodontic guides were fabricated according to baseline cone-beam computed tomography (CBCT) and intraoral optical scans using Blue Sky software. In the single-sleeve endodontic guides group (SSG), two anterior and two posterior teeth were included in a 5-unit guide. In the double-sleeve endodontic guides group (DSG) group, the guide was passed through the midline to include both canine teeth and extended by 2 teeth posterior to the canine teeth bilaterally (a 10-unit guide). After drilling, postoperative CBCT scans were taken and superimposed on the virtually designed path, and the maximum coronal deviation (MCD) at the marginal entry point of the tooth, maximum apical deviation (MAD) at 10 mm apical to the tooth margin, and maximum angular deflection (MAnD) of the drill were calculated. RESULTS: The mean MCD, MAD, and MAnD were 0.34 mm, 0.6 mm, and 2.32 degrees, respectively, in the SSG and 0.31 mm, 0.7 mm, and 2.37 degrees, respectively, in the DSG. The two groups were not significantly different from each other in terms of MCD (P = 0.573), MAD (P = 0.290), or MAnD (P = 0.896). CONCLUSIONS: The accuracies of the two techniques, the extended double sleeve guide and the single sleeve guide, were comparable and thus DSG may be used for removal of fiber posts in adjacent or distant teeth.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Técnica para Retentor Intrarradicular , Humanos , Técnica para Retentor Intrarradicular/instrumentação , Dente Canino/diagnóstico por imagem , Técnicas In Vitro
14.
Med Sci Monit ; 30: e944110, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38685688

RESUMO

BACKGROUND A luting agent is a dental cement used to secure a dental restoration. This study aimed to evaluate retentive strength of 50 endodontically-treated single-rooted mandibular second premolars (extracted) restored using 5 common luting (cement) agents. MATERIAL AND METHODS Fifty single-rooted mandibular second premolars with adequate root length and uniform size/shape were decoronated. After completing endodontic biomechanical preparation and obturation, root canals of all specimens were prepared to receive a cast post core. Depending upon cementation type, CPC specimens were divided in 5 groups (10 each) (Gp): Zinc phosphate (Gp ZP), polycarboxylate (Gp PC), glass ionomer (Gp GI), resin-modified glass ionomer (Gp RGI), and resin cement (Gp RC). Retentive strength was determined using the adhesive failure pull-out test. Mean/standard deviations were calculated for tensile forces (in kilograms) and differences were determined using analysis of variance (ANOVA). Multiple comparison was performed using the t test. A P value of ≤0.05 indicated a statistically significant difference. RESULTS The order of mean tensile strength from higher to lower was Gp RC (21.46) >Gp RGI (18.17) >Gp GI (16.07) >Gp ZP (15.33) >Gp PC (13.63). Differences in retentive strengths between the cements were significant (P≤0.05). Multiple-group comparisons showed that except for Gp ZP and Gp GI, all groups differed significantly from each other. CONCLUSIONS All investigated cements provided optimal retentive strengths, with wide differences between them. Resin cements should be used when CPC removal is not anticipated, while polycarboxylate or zinc phosphate should be used if CPC removal is anticipated.


Assuntos
Dente Pré-Molar , Cimentos Dentários , Humanos , Mandíbula , Técnica para Retentor Intrarradicular , Cimentos de Ionômeros de Vidro , Cimentos de Resina , Resistência à Tração , Teste de Materiais/métodos , Restauração Dentária Permanente/métodos , Raiz Dentária/efeitos dos fármacos , Cimento de Fosfato de Zinco
15.
Compend Contin Educ Dent ; 45(4): 184-190; quiz 191, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38622077

RESUMO

Post and core systems have long been used in dentistry for the purposes of replacing missing coronal tooth structure, retaining the core, and providing sufficient retention and resistance form to the final restoration to re-establish original form and function. While Part 1 of this two-part article provided a history of post and core systems and materials and discussed empirical data regarding fiber-reinforced post systems, this second part of the article focuses on an alternative approach for developing a fiber-reinforced post and core system using a monoblock system via the injectable resin technique and a recently developed fiber-optic post. The present article explains the concept of a ferrule effect and demonstrates the novel restorative procedure.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Resinas Compostas/uso terapêutico , Resinas Compostas/química , Análise do Estresse Dentário
16.
J Endod ; 50(7): 976-981, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38522577

RESUMO

INTRODUCTION: The aim of this study was to investigate the feasibility of a real-time three-dimensional dynamic navigation system (3D-DNS) for post space preparation (PSP) in root canal-treated teeth and to compare the accuracy and efficiency of 3D-DNS to freehand (FH) for PSP. METHODS: Fifty-four maxillary molars were divided into two groups: 3D-DNS (n = 27) and FH group (n = 27). Cone beam computed tomography (CBCT) scans were taken preoperatively and postoperatively. The drilling path for the PSP was virtually planned in the preoperative CBCT scan in the X-guide software (X-Nav Technologies, Lansdale, PA). For the 3D-DNS group, the PSP drilling was conducted under dynamic navigation. The 3D deviations and angular deflections were calculated. The residual dentin thickness (RDT) was determined after PSP. The operation time and the total number of mishaps were recorded. Shapiro-Wilk, t-test or Mann-Whitney rank sum, weighted Cohen's kappa, and Fisher exact tests were used (P < .05). RESULTS: The PSP was completed in all samples (54/54). The 3D-DNS was more accurate than the FH, with significantly fewer 3D deviations and angular deflections (all, P < .05). The 3D-DNS required less operating time than the FH (P < .05). For the 3D-DNS, no teeth had RDT < 1 mm, whereas 6/27 in the FH showed RDT < 1 mm after the PSP. There was no difference in the total number of mishaps (P > .05). CONCLUSION: Within the limitations of this in vitro study, the 3D-DNS is feasible for PSP. The 3D-DNS improved the accuracy and efficiency of PSP. The dynamic navigation system can potentially become a safe and reliable technology for PSP.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Técnicas In Vitro , Dente Molar/diagnóstico por imagem , Técnica para Retentor Intrarradicular , Preparo de Canal Radicular/métodos , Preparo de Canal Radicular/instrumentação , Estudos de Viabilidade , Tratamento do Canal Radicular/métodos
17.
Compend Contin Educ Dent ; 45(3): 128-134; quiz 135, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38460136

RESUMO

Post systems have long been used in the roots of teeth to retain dental restorations. The primary objectives of current post and core systems are to replace missing coronal tooth structure, retain the core, and provide sufficient retention and resistance form to the final restoration to restore original form and function. Many varieties of user-friendly post and core systems are available today for different endodontic, restorative, and esthetic requirements. The present article provides a history of post and core usage in dentistry, describes various systems and materials for this purpose, and discusses empirical data regarding fiber-reinforced post systems.


Assuntos
Técnica para Retentor Intrarradicular , Dente não Vital , Humanos , Resinas Compostas/química , Estética Dentária
18.
Int J Prosthodont ; 37(7): 127-131, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38498864

RESUMO

PURPOSE: To evaluate and compare the fracture resistance and elastic modulus of 3D-printed post and core systems and fiber posts and composite cores. MATERIALS AND METHODS: Endodontic treatment was performed on 30 mandibular premolars, and post space preparation was performed. The teeth were then randomly divided into two groups (n = 15 per group): the 3D-printed (3DP) group and the fiber post and composite core (FPC) group. In the FPC group, fiber posts (Cytec Blanco 43.604, Hahnenkratt) were bonded with resin cement (RelyX U200, 3M), and the composite core dimension was standardized with a silicone index. In the 3DP group, the impression of the post space for each specimen was taken with pattern resin (Pattern Resin, GC America), and the coronal core was produced with the same silicone index. The impressions of the posts and cores were scanned, and then the custom post and core structures were fabricated from permanent crown resin material (Permanent Crown Resin, Formlabs) with a 3D printer (Form3B, Formlabs). Specimens were subjected to load tests with a universal testing machine (M500-25AT, Testometric). After fracture occurred, the fracture force and elastic modulus were calculated. The data were analyzed by independent sample t test (α = .05) Results: There was no statistically significant difference between the two groups in terms of peak fracture force (P = .626) and elastic modulus (P = .125), and no catastrophic root fractures were observed in either group. CONCLUSIONS: The fracture resistance of endodontically treated teeth was not significantly influenced by the post material. 3D-printed, custom-made resin posts were as effective as fiber glass posts with regard to fracture resistance.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Resinas Compostas/química , Coroas , Vidro/química , Cimentos de Resina/química , Silicones , Impressão Tridimensional , Dente não Vital/terapia , Análise do Estresse Dentário
19.
BMC Oral Health ; 24(1): 337, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491485

RESUMO

BACKGROUND: The selection of post-core material holds significant importance in endodontically treated teeth, influencing stress distribution in the dental structure after restoration. The use of computer-aided design/computer-aided manufacturing (CAD/CAM) glass fiber post-core possesses a better adaptation for different root canal morphologies, but whether this results in a more favorable stress distribution has not been clearly established. MATERIALS AND METHODS: This study employed finite element analysis to establish three models of post-core crown restoration with normal, oversized, and dumbbell-shaped root canals. The three models were restored using three different materials: CAD/CAM glass fiber post-core (CGF), prefabricated glass fiber post and resin core (PGF), and cobalt-chromium integrated metal post-core (Co-Cr), followed by zirconia crown restoration. A static load was applied and the maximum equivalent von Mises stress, maximum principal stress, stress distribution plots, and the peak of maximum displacement were calculated for dentin, post-core, crown, and the cement acting as the interface between the post-core and the dentin. RESULTS: In dentin of three different root canal morphology, it was observed that PGF exhibited the lowest von Mises stresses, while Co-Cr exhibited the highest ones under a static load. CGF showed similar stress distribution to that of Co-Cr, but the stresses were more homogeneous and concentrated apically. In oversized and dumbbell-shaped root canal remnants, the equivalent von Mises stress in the cement layer using CGF was significantly lower than that of PGF. CONCLUSIONS: In oversized root canals and dumbbell-shaped root canals, CGF has shown good performance for restoration of endodontically treated teeth. CLINICAL RELEVANCE: This study provides a theoretical basis for clinicians to select post-core materials for residual roots with different root canal morphologies and should help to reduce the occurrence of complications such as root fracture and post-core debonding.


Assuntos
Vidro , Técnica para Retentor Intrarradicular , Dente não Vital , Humanos , Coroas , Cimentos Dentários , Cimentos de Ionômeros de Vidro , Desenho Assistido por Computador , Análise do Estresse Dentário/métodos , Análise de Elementos Finitos , Resinas Compostas/química , Teste de Materiais , Estresse Mecânico
20.
J Contemp Dent Pract ; 25(1): 72-78, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38514435

RESUMO

AIM: In comparing the effectiveness and efficiency of different types of post removal systems in removing different types of fiber posts (FPs), this study aims to shed light on the success of removal by currently available drill systems. MATERIALS AND METHODS: A total of 200 maxillary first molars, were root canal treated and prepared to receive posts. The molars were divided into four groups corresponding to four different FPs: Group RX, Radix FP; Group RF, Reforpost Glass Fiber; Group HI; Hi-Rem Endodontic Post; and Group DT, D.T. Light-Post Illusion X-RO. Fiber posts were done with luting by Gradia Core (GC America, Inc.). Groups were again divided into five subgroups corresponding to the technique by which the FP was removed into as follows: Subgroup P, PD-25-1.1 Drill; subgroup G, GC FP Drill; subgroup E, EasyPost Precision Drill; subgroup R, Reaccess Carbide Double Taper Kit; and subgroup H; H-Endodontic Drill. After posts were removed, effectiveness and efficiency were documented. Data were tabulated and statistically analyzed. RESULTS: Strong significant differences regarding efficiency among groups (FP type) and subgroups (drills used) (p = 0.00) were shown by the one-way analysis of variance (ANOVA) test. Subgroup DT-G scored the longest mean removal time (20.9 minutes) while Subgroup RX-R scored the shortest mean removal time (1.4 minutes) Regarding effectiveness, strong significant differences among groups (p = 0.00) and subgroups (p = 0.00) were shown by one-way ANOVA. Subgroup RF-G scored the highest scale (5.2) whereas subgroup HI-R scored the lowest mean scale (1.2). CONCLUSION: The difference was strongly significant between tested post-removal kits and between tested FPs. Re-access Carbide Double Taper Kit performed superiorly in both effectiveness and efficiency, followed by PD-25-1.1 Drill. Hi-Rem post showed the best retrieving results among other FPs. CLINICAL SIGNIFICANCE: Knowing the best technique and tools for post removal could spare the practitioner any unwanted complications during post removal. How to cite this article: Sayed M, Alahmad AM, Alhajji KS, et al. Removal Efficiency and Effectiveness of Four Different Fiber Posts Using Five Different Drill Systems in Multirooted Teeth. J Contemp Dent Pract 2024;25(1):72-78.


Assuntos
Técnica para Retentor Intrarradicular , Dente não Vital , Humanos , Tratamento do Canal Radicular , Dente não Vital/terapia , Vidro , Teste de Materiais , Cimentos de Resina , Análise do Estresse Dentário
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...