Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30.150
Filtrar
1.
Ann Phys Rehabil Med ; 67(5): 101839, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38824898

RESUMO

BACKGROUND: Percutaneous needle tenotomies constitute a promising approach that enables direct access to tendons through minimally invasive interventions. They can be performed rapidly without need for large incisions or general anaesthesia. However, the reported procedures are heterogeneous and currently conducted without guidelines. OBJECTIVES: We aimed to determine the indications for percutaneous needle tenotomies described in the current literature. Our secondary aim was to identify the different procedures reported, as well as their efficacy and their safety. METHODS: A systematic review following PRISMA guidelines was conducted to identify original articles that mentioned percutaneous needle tenotomy in humans and reported its application, description, effectiveness or adverse events. Non-percutaneous tendinous surgical procedures and ineligible designs were excluded. The Downs and Black checklist was used to assess the risk of bias. RESULTS: A total of 540 studies were identified from the MEDLINE, Embase, Cochrane Library, and PEDro databases. Fourteen clinical studies met the inclusion criteria and were found to have an acceptable quality (674 individuals, 1664 tenotomies). Our results indicated a wide variety of indications for percutaneous needle tenotomies in children and in adults. We highlighted 24 tendons as eligible targets in the upper and lower limbs. Tenotomies were performed with either 16- or 18-Ga needles, lasted from 1 to 30 min, and were performed using various procedures. Their efficacy was mainly assessed through clinical outcomes highlighting tendon discontinuity on palpation after the procedure. Passive range-of-motion gains after tenotomy were reported for both upper and lower limbs with an estimated 5 % complication rate. CONCLUSION: This is the first review to systematically synthesize all the available evidence on the indications, procedures, efficacy and safety of percutaneous tenotomies exclusively performed with needles. Current evidence suggests that procedures are safe and effective for treating various deformities. PROSPERO REGISTRATION: CRD42022350571.


Assuntos
Agulhas , Tenotomia , Humanos , Tenotomia/métodos , Criança , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Adulto , Resultado do Tratamento , Tendões/cirurgia
2.
Sultan Qaboos Univ Med J ; 24(2): 268-271, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38828237

RESUMO

This technical note aimed to present a straigthforward method for harvesting quadriceps tendon autografts with the use of a simple vaginal speculum and direct visualisation of a scope. Anterior cruciate ligament reconstruction with quadriceps tendon autografts has gained popularity in recent years, with many harvesting techniques that use different harvesting systems available on the market. These techniques vary from transverse to longitudinal skin incisions and from open to minimally invasive approaches and have a learning curve, as with the majority of surgical procedures. The technique proposed in this technical note is minimally invasive, can be easily reproduced by any surgeon irrespective of their experience, has a short learning curve, requires no additional cost or technical support during the procedure and creates a stable working space that allows for freedom of manipulation of surgical instruments and the arthroscope.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Humanos , Reconstrução do Ligamento Cruzado Anterior/métodos , Reconstrução do Ligamento Cruzado Anterior/instrumentação , Feminino , Autoenxertos , Coleta de Tecidos e Órgãos/métodos , Coleta de Tecidos e Órgãos/instrumentação , Tendões , Músculo Quadríceps , Transplante Autólogo/métodos , Instrumentos Cirúrgicos
3.
Sci Rep ; 14(1): 13540, 2024 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-38866832

RESUMO

Mast cells are immune cells minimally present in normal tendon tissue. The increased abundance of mast cells in tendinopathy biopsies and at the sites of tendon injury suggests an unexplored role of this cell population in overuse tendon injuries. Mast cells are particularly present in tendon biopsies from patients with more chronic symptom duration and a history of intensive mechanical loading. This study, therefore, examined the cross talk between mast cells and human tendon cells in either static or mechanically active conditions in order to explore the potential mechanistic roles of mast cells in overuse tendon injuries. A coculture of isolated human tenocytes and mast cells (HMC-1) combined with Flexcell Tension System for cyclic stretching of tenocytes was used. Additionally, human tenocytes were exposed to agonists and antagonists of substance P (SP) receptors. Mast cell degranulation was assessed by measuring ß-hexosaminidase activity. Transwell and cell adhesion assays were used to evaluate mast cell migration and binding to tendon extracellular matrix components (collagen and fibronectin), respectively. Gene expressions were analyzed using real time qRT-PCR. Our results indicate that mechanical stimulation of human tenocytes leads to release of SP which, in turn, activates mast cells through the Mas-related G-protein-coupled receptor X2 (MRGPRX2). The degranulation and migration of mast cells in response to MRGPRX2 activation subsequently cause human tenocytes to increase their expression of inflammatory factors, matrix proteins and matrix metalloproteinase enzymes. These observations may be important in understanding the mechanisms by which tendons become tendinopathic in response to repetitive mechanical stimulation.


Assuntos
Mastócitos , Receptores Acoplados a Proteínas G , Receptores de Neuropeptídeos , Substância P , Tendões , Tenócitos , Humanos , Substância P/metabolismo , Substância P/farmacologia , Mastócitos/metabolismo , Tenócitos/metabolismo , Receptores Acoplados a Proteínas G/metabolismo , Receptores de Neuropeptídeos/metabolismo , Receptores de Neuropeptídeos/genética , Tendões/metabolismo , Tendões/patologia , Proteínas do Tecido Nervoso/metabolismo , Proteínas do Tecido Nervoso/genética , Degranulação Celular , Tendinopatia/metabolismo , Tendinopatia/patologia , Inflamação/metabolismo , Inflamação/patologia , Masculino , Técnicas de Cocultura , Células Cultivadas , Adulto , Movimento Celular
4.
J Musculoskelet Neuronal Interact ; 24(2): 159-167, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38825998

RESUMO

OBJECTIVE: To compare the effects of anchor reconstruction of posterior tibial tendon with the traditional Kidner's procedure for accessory navicular bone syndrome. METHODS: A retrospective analysis was conducted on 40 young athletes diagnosed with accessory navicular bone syndrome who were admitted to our hospital from 2018 to 2021. Among them, 20 patients underwent the modified Kidner procedure for the anchor reconstruction of the posterior tibial tendon (Experimental group), while the remaining 20 patients were treated with the traditional Kidner's procedure (Control group). Regular follow-ups were conducted to evaluate the degree of relief of foot symptoms and functional recovery. RESULTS: All patients were followed up for 12 to 24 months (mean duration: 18.6±3.7) after the operation. At the last follow-up, significant differences were observed in the function and symptom relief of the affected foot compared to the preoperative state. The experimental group had a mean operation time of 52.10 ± 3.41 minutes, significantly shorter than the control group's 61.25 ± 2.75 minutes. The mean time to return to normal activity was 12.65 ± 1.23 weeks for the experimental group, compared to 15.25 ± 1.16 weeks for the control group. CONCLUSION: The modified Kidner procedure demonstrates a higher patient satisfaction rate compared to the traditional Kidner procedure. This is attributed to its shorter duration, reduced trauma, and quicker recovery of normal activity.


Assuntos
Procedimentos de Cirurgia Plástica , Ossos do Tarso , Humanos , Masculino , Ossos do Tarso/cirurgia , Ossos do Tarso/diagnóstico por imagem , Ossos do Tarso/anormalidades , Feminino , Estudos Retrospectivos , Adolescente , Procedimentos de Cirurgia Plástica/métodos , Atletas , Resultado do Tratamento , Tendões/cirurgia , Criança , Adulto Jovem , Doenças do Pé
7.
PeerJ ; 12: e17179, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38803578

RESUMO

Surgical intervention is a common option for the treatment of wrist joint arthritis and traumatic wrist injury. Whether this surgery is arthrodesis or a motion preserving procedure such as arthroplasty, wrist joint biomechanics are inevitably altered. To evaluate effects of surgery on parameters such as range of motion, efficiency and carpal kinematics, repeatable and controlled motion of cadaveric specimens is required. This study describes the development of a device that enables cadaveric wrist motion to be simulated before and after motion preserving surgery in a highly controlled manner. The simulator achieves joint motion through the application of predetermined displacements to the five major tendons of the wrist, and records tendon forces. A pilot experiment using six wrists aimed to evaluate its accuracy and reproducibility. Biplanar X-ray videoradiography (BPVR) and X-Ray Reconstruction of Moving Morphology (XROMM) were used to measure overall wrist angles before and after total wrist arthroplasty. The simulator was able to produce flexion, extension, radioulnar deviation, dart thrower's motion and circumduction within previously reported functional ranges of motion. Pre- and post-surgical wrist angles did not significantly differ. Intra-specimen motion trials were repeatable; root mean square errors between individual trials and average wrist angle and tendon force profiles were below 1° and 2 N respectively. Inter-specimen variation was higher, likely due to anatomical variation and lack of wrist position feedback. In conclusion, combining repeatable intra-specimen cadaveric motion simulation with BPVR and XROMM can be used to determine potential effects of motion preserving surgeries on wrist range of motion and biomechanics.


Assuntos
Cadáver , Amplitude de Movimento Articular , Articulação do Punho , Humanos , Articulação do Punho/cirurgia , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/fisiologia , Articulação do Punho/anatomia & histologia , Fenômenos Biomecânicos , Radiografia/métodos , Masculino , Idoso , Reprodutibilidade dos Testes , Tendões/cirurgia , Tendões/diagnóstico por imagem , Tendões/fisiologia , Tendões/anatomia & histologia , Feminino
8.
Sci Robot ; 9(90): eadl0085, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809994

RESUMO

Sensory feedback for prosthesis control is typically based on encoding sensory information in specific types of sensory stimuli that the users interpret to adjust the control of the prosthesis. However, in physiological conditions, the afferent feedback received from peripheral nerves is not only processed consciously but also modulates spinal reflex loops that contribute to the neural information driving muscles. Spinal pathways are relevant for sensory-motor integration, but they are commonly not leveraged for prosthesis control. We propose an approach to improve sensory-motor integration for prosthesis control based on modulating the excitability of spinal circuits through the vibration of tendons in a closed loop with muscle activity. We measured muscle signals in healthy participants and amputees during different motor tasks, and we closed the loop by applying vibration on tendons connected to the muscles, which modulated the excitability of motor neurons. The control signals to the prosthesis were thus the combination of voluntary control and additional spinal reflex inputs induced by tendon vibration. Results showed that closed-loop tendon vibration was able to modulate the neural drive to the muscles. When closed-loop tendon vibration was used, participants could achieve similar or better control performance in interfaces using muscle activation than without stimulation. Stimulation could even improve prosthetic grasping in amputees. Overall, our results indicate that closed-loop tendon vibration can integrate spinal reflex pathways in the myocontrol system and open the possibility of incorporating natural feedback loops in prosthesis control.


Assuntos
Amputados , Membros Artificiais , Retroalimentação Sensorial , Mãos , Músculo Esquelético , Desenho de Prótese , Reflexo , Vibração , Humanos , Adulto , Mãos/fisiologia , Masculino , Feminino , Retroalimentação Sensorial/fisiologia , Reflexo/fisiologia , Músculo Esquelético/fisiologia , Músculo Esquelético/inervação , Eletromiografia , Tendões/fisiologia , Neurônios Motores/fisiologia , Pessoa de Meia-Idade , Força da Mão/fisiologia , Adulto Jovem
9.
Biol Open ; 13(5)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38780905

RESUMO

Skeletal muscles and the tendons that attach them to bone are structurally complex and deform non-uniformly during contraction. While these tissue deformations dictate force production during movement, our understanding of this behaviour is limited due to challenges in obtaining complete measures of the constituent structures. To address these challenges, we present an approach for simultaneously measuring muscle, fascicle, aponeurosis, and tendon behaviour using sonomicrometry. To evaluate this methodology, we conducted isometric and dynamic contractions in in situ rabbit medial gastrocnemius. We found comparable patterns of strain in the muscle belly, fascicle, aponeurosis, and tendon during the isometric trials to those published in the literature. For the dynamic contractions, we found that our measures using this method were consistent across all animals and aligned well with our theoretical understanding of muscle-tendon unit behaviour. Thus, this method provides a means to fully capture the complex behaviour of muscle-tendon units across contraction types.


Assuntos
Aponeurose , Contração Muscular , Músculo Esquelético , Tendões , Tendões/fisiologia , Animais , Coelhos , Aponeurose/fisiologia , Músculo Esquelético/fisiologia , Contração Muscular/fisiologia , Fenômenos Biomecânicos
10.
Biomater Adv ; 161: 213873, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38692180

RESUMO

The muscle tendon junction (MTJ) plays a crucial role in transmitting the force generated by muscles to the tendon and then to the bone. Injuries such as tears and strains frequently happen at the MTJ, where the regenerative process is limited due to poor vascularization and the complex structure of the tissue. Current solutions for a complete tear at the MTJ have not been successful and therefore, the development of a tissue-engineered MTJ may provide a more effective treatment. In this study, decellularised extracellular matrix (DECM) derived from sheep MTJ was used to provide a scaffold for the MTJ with the relevant mechanical properties and differentiation cues such as the relase of growth factors. Human mesenchymal stem cells (MSCs) were seeded on DECM and 10 % cyclic strain was applied using a bioreactor. MSCs cultured on DECM showed significantly higher gene and protein expression of MTJ markers such as collagen 22, paxillin and talin, than MSCs in 2D culture. Although collagen 22 protein expression was higher in the cells with strain than without strain, reduced gene expression of other MTJ markers was observed when the strain was applied. DECM combined with 10 % strain enhanced myogenic differentiation, while tenogenic differentiation was reduced when compared to static cultures of MSCs on DECM. For the first time, these results showed that DECM derived from the MTJ can induce MTJ marker gene and protein expression by MSCs, however, the effect of strain on the MTJ development in DECM culture needs further investigation.


Assuntos
Diferenciação Celular , Células-Tronco Mesenquimais , Tendões , Engenharia Tecidual , Células-Tronco Mesenquimais/metabolismo , Células-Tronco Mesenquimais/citologia , Tendões/citologia , Tendões/metabolismo , Tendões/fisiologia , Humanos , Animais , Engenharia Tecidual/métodos , Ovinos , Alicerces Teciduais/química , Matriz Extracelular Descelularizada/metabolismo , Resistência à Tração , Matriz Extracelular/metabolismo , Células Cultivadas
11.
Anat Sci Int ; 99(3): 290-304, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38717695

RESUMO

This study aimed to describe the shoulder anatomy, together with the anatomical relationships in adults and early stages of development. The shoulder muscles were studied from ultrasound, anatomical, and microscopic perspectives in a sample of 34 human shoulders. Thickness measurements were taken of the tendons and fasciae of the subscapularis, long head tendon of the biceps brachii, supraspinatus, infraspinatus, and teres minor. Ultrasound and dissection techniques are strongly correlated. However, the measurements obtained from the dissection technique were superior to those obtained from the ultrasound in all cases, except for the thickness of the long head tendon of the biceps brachii, the teres minor tendon, and the fascia thickness of the infraspinatus. In addition, the study of shoulder anatomy revealed no differences between females and males. Relevant findings from dissection included a clear overlap between the infraspinatus and supraspinatus, which shared tendon fibers, and a similar connection between the transverse ligament of the long head tendon of the biceps brachii and the subscapularis, which created a more interconnected shoulder function. The study of the anatomical measurements shows an underestimation of the shoulder measurements in the ultrasound compared with the dissection technique, but a high correlation between the measurements made by the two techniques. We present reference values for the tendon and fascia thicknesses of the rotator cuff, with no differences observed by gender. The relationships between shoulder structures described in the anatomical study imply as well that, in the event of an injury, adjacent tissues may be affected. This extended information may facilitate future optimal clinical explorations.


Assuntos
Ombro , Tendões , Ultrassonografia , Humanos , Ultrassonografia/métodos , Masculino , Feminino , Ombro/anatomia & histologia , Ombro/diagnóstico por imagem , Tendões/anatomia & histologia , Tendões/diagnóstico por imagem , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/anatomia & histologia , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/diagnóstico por imagem , Adulto , Dissecação , Articulação do Ombro/anatomia & histologia , Articulação do Ombro/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso
12.
Am J Sports Med ; 52(7): 1784-1793, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38721771

RESUMO

BACKGROUND: The vancomycin presoaking technique (wherein grafts are treated with a vancomycin solution [VS] for anterior cruciate ligament reconstruction [ACLR]) reduces the infection rate after ACLR. However, the effects of this technique on graft-bone healing have not been fully elucidated. PURPOSE: To investigate the effects of vancomycin presoaking on graft-bone healing in a rat ACLR model. STUDY DESIGN: Controlled laboratory study. METHODS: Long flexor digitorum longus tendons were obtained from 9 Wistar rats, and each was randomly allocated to the normal saline (NS) or VS groups. The grafts were immersed in sterile saline for 30 minutes in the NS group and in a 5-mg/mL VS in the VS group. The presence of time-zero graft bacterial contamination was confirmed, and the grafts were incubated in Fluidised Thioglycollate Broth for 2 weeks. ACLR was performed on the right knees of 65 male Wistar rats using the flexor digitorum longus tendons. Each graft was similarly treated. Biomechanical testing, micro-computed tomography, and histological evaluations were performed 4 and 12 weeks postoperatively. RESULTS: The VS group showed significantly reduced graft contamination at time zero (P = .02). The mean maximum loads to failure were 13.7 ± 8.2 N and 11.6 ± 4.8 N in the NS and VS groups, respectively, at 4 weeks (P = .95); and 23.2 ± 13.2 N and 30.4 ± 18.0 N in the NS and VS groups, respectively, at 12 weeks (P = .35). Regarding micro-computed tomography, the mean bone tunnel volumes were 3.76 ± 0.48 mm3 and 4.40 ± 0.58 mm3 in the NS and VS groups, respectively, at 4 weeks (P = .41); and 3.51 ± 0.38 mm3 and 3.67 ± 0.35 mm3 in the NS and VS groups, respectively, at 12 weeks (P = .54). Histological semiquantitative examination revealed no clear between-group differences at any time point. CONCLUSION: Presoaking grafts in vancomycin in a rat ACLR model demonstrated no discernible adverse effects on short- and midterm biomechanical, radiological, and histological investigations. CLINICAL RELEVANCE: The findings provide guidance for surgeons when considering this technique.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Ratos Wistar , Vancomicina , Animais , Vancomicina/farmacologia , Reconstrução do Ligamento Cruzado Anterior/métodos , Masculino , Ratos , Antibacterianos/farmacologia , Tendões/transplante , Tendões/efeitos dos fármacos , Cicatrização/efeitos dos fármacos , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Microtomografia por Raio-X
13.
Am J Sports Med ; 52(7): 1753-1764, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38761016

RESUMO

BACKGROUND: The indirect head of the rectus femoris (IHRF) tendon has been used as an autograft for segmental labral reconstruction. However, the biomechanical properties and anatomic characteristics of the IHRF, as they relate to surgical applications, have yet to be investigated. PURPOSE: To (1) quantitatively and qualitatively describe the anatomy of IHRF and its relationship with surrounding arthroscopically relevant landmarks; (2) detail radiographic findings pertinent to IHRF; (3) biomechanically assess segmental labral reconstruction with IHRF, including restoration of the suction seal and contact pressures in comparison with iliotibial band (ITB) reconstruction; and (4) assess potential donor-site morbidity caused by graft harvesting. STUDY DESIGN: Descriptive laboratory study. METHODS: A cadaveric study was performed using 8 fresh-frozen human cadaveric full pelvises and 7 hemipelvises. Three-dimensional anatomic measurements were collected using a 3-dimensional coordinate digitizer. Radiographic analysis was accomplished by securing radiopaque markers of different sizes to the evaluated anatomic structures of the assigned hip.Suction seal and contact pressure testing were performed over 3 trials on 6 pelvises under 4 different testing conditions for each specimen: intact, labral tear, segmental labral reconstruction with ITB, and segmental labral reconstruction with IHRF. After IHRF tendon harvest, each full pelvis had both the intact and contralateral hip tested under tension along its anatomic direction to assess potential site morbidity, such as tendon failure or bony avulsion. RESULTS: The centroid and posterior apex of the indirect rectus femoris attachment are respectively located 10.3 ± 2.6 mm and 21.0 ± 6.5 mm posteriorly, 2.5 ± 7.8 mm and 0.7 ± 8.0 mm superiorly, and 5.0 ± 2.8 mm and 22.2 ± 4.4 mm laterally to the 12:30 labral position. Radiographically, the mean distance of the IHRF to the following landmarks was determined as follows: anterior inferior iliac spine (8.8 ± 2.5 mm), direct head of the rectus femoris (8.0 ± 3.9 mm), 12-o'clock labral position (14.1 ± 2.8 mm), and 3-o'clock labral position (36.5 ± 4.4 mm). During suction seal testing, both the ITB and the IHRF reconstruction groups had significantly lower peak loads and lower energy to peak loads compared with both intact and tear groups (P = .01 to .02 for all comparisons). There were no significant differences between the reconstruction groups for peak loads, energy, and displacement at peak load. In 60° of flexion, there were no differences in normalized contact pressure and contact area between ITB or IHRF reconstruction groups (P > .99). There were no significant differences between intact and harvested specimen groups in donor-site morbidity testing. CONCLUSION: The IHRF tendon is within close anatomic proximity to arthroscopic acetabular landmarks. In the cadaveric model, harvesting of the IHRF tendon as an autograft does not lead to significant donor-site morbidity in the remaining tendon. Segmental labral reconstruction performed with the IHRF tendon exhibits similar biomechanical outcomes compared with that performed with ITB. CLINICAL RELEVANCE: This study demonstrates the viability of segmental labral reconstruction with an IHRF tendon and provides a detailed anatomic description of the tendon in the context of an arthroscopic labral reconstruction. Clinicians can use this information during the selection of a graft and as a guide during an arthroscopic graft harvest.


Assuntos
Cadáver , Tendões , Humanos , Fenômenos Biomecânicos , Tendões/transplante , Articulação do Quadril/cirurgia , Articulação do Quadril/diagnóstico por imagem , Masculino , Músculo Quadríceps/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade , Idoso , Radiografia
14.
Cell Tissue Bank ; 25(2): 705-712, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38724712

RESUMO

To compare 2 different graft preparation techniques to determine biomechanical strength and resultant tissue trauma evaluated by histology. Twelve common flexors of the finger's tendons were prepared with either tubulization (SpeedTrap™) or transtendon stiches (Orthocord™). The stiffness, resistance and energy at maximum load were tested for biomechanical assessment in both groups. After load testing, Samples were stained with hematoxylin and eosin (HE) to evaluate histological damage. We observe that the time to prepare tendons with SpeedTrap™ was 8.3 times faster (1:25 min) than traditional ones (15:02 min). In all cases, the mean values for SpeedTrap™ were higher in terms of strength, stiffness and energy at maximum load than for traditional suture but without significant difference (p > 0.05). The Krackow stitch produces greater structural damage to the collagen fibers while SpeedTrap™ maintains better organized arrangement of the fibers after tubulization preparation. With the results obtained, we can conclude that the tubulization technique allows faster graft preparation with less structural damage to the manipulated tissue without altering the biomechanical resistance provided by the transtendon suture technique.


Assuntos
Técnicas de Sutura , Suturas , Tendões , Fenômenos Biomecânicos , Tendões/fisiologia , Humanos , Resistência à Tração
15.
J Hand Surg Asian Pac Vol ; 29(3): 256-260, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38726495

RESUMO

Volar dislocation of the distal radioulnar joint is a rare injury that is often missed at initial presentation. We report a 21-year-old male patient who presented 2 months after sustaining this injury. He was successfully managed by open reduction and reconstruction of the dorsal radioulnar ligament using a partial distally based extensor carpi ulnaris tendon strip. A literature review showed only a few reported cases with varied methods for management. The technique utilised is analysed in comparison to the others. Level of Evidence: Level V (Therapeutic).


Assuntos
Luxações Articulares , Traumatismos do Punho , Humanos , Masculino , Adulto Jovem , Luxações Articulares/cirurgia , Luxações Articulares/diagnóstico por imagem , Traumatismos do Punho/cirurgia , Traumatismos do Punho/diagnóstico por imagem , Tendões/cirurgia , Articulação do Punho/cirurgia , Ligamentos Articulares/cirurgia , Ligamentos Articulares/lesões
16.
Anat Sci Int ; 99(3): 326-330, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38733476

RESUMO

The extensor digitorum profundus complex underwent degeneration of the ulnar segments during primate adaptation and evolution. This process resulted in the preservation of only the extensor pollicis longus and extensor indicis in some apes, including humans. Consequently, anatomical variations within the digitorum profundus complex in modern humans have been well-documented, with detailed reports on their frequency and patterns in previous studies. Here, we report an unusual arrangement involving two anomalies in the extensor digitorum profundus complex, identified in a 66-year-old Japanese male cadaver. In this cadaver, two accessory muscles differentiated from both the extensor pollicis longus and extensor indicis. Notably, the latter muscle featured a tendon bifurcating towards both the thumb and index fingers, referred to as the extensor pollicis et indicis communis. Under the extensor retinaculum, the tendon of the accessory extensor pollicis longus passed through an independent compartment, whereas that of the extensor pollicis et indicis communis traversed a compartment shared by the extensor indicis and the extensor digitorum communis. Both muscles were innervated by the posterior interosseous nerve. Previous studies have reported that the accessory slip of the extensor pollicis longus and extensor pollicis et indicis communis appear at frequencies of 0.6% and 0.4-1.4%, respectively. However, to the best of our knowledge, a configuration in which both appear simultaneously has not been reported. The data from this case could provide essential insights into the variations in the extensor digitorum profundus complex in humans and non-human primates.


Assuntos
Cadáver , Músculo Esquelético , Tendões , Humanos , Masculino , Idoso , Músculo Esquelético/anormalidades , Músculo Esquelético/anatomia & histologia , Tendões/anormalidades , Tendões/anatomia & histologia , Dedos/anormalidades , Dedos/anatomia & histologia , Variação Anatômica , Polegar/anormalidades
17.
Musculoskelet Surg ; 108(2): 153-162, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38713360

RESUMO

PURPOSE: It is unclear which triceps tendon repair constructs and techniques produce the strongest biomechanical performance while minimizing the risk of gap formation and repair failure. We aimed to determine associations of construct and technique variables with the biomechanical strength of triceps tendon repairs. PubMed, Embase, Cochrane Library, Web of Science, Scopus, and ClinicalTrials.gov were systematically searched for peer-reviewed studies on biomechanical strength of triceps tendon repairs in human cadavers. 6 articles met the search criteria. Meta-regression was performed on the pooled dataset (123 specimens). Outcomes of interest included gap formation, failure mode, and ultimate failure load. Covariates were fixation type; number of implants; and number of sutures. Stratification by covariates was performed. We found no association between fixation type and ultimate failure load; however, suture anchor fixation was associated with less gap formation compared with transosseous direct repair (ß = - 1.1; 95% confidence interval [CI]:- 2.2, - 0.04). A greater number of implants was associated with smaller gap formation (ß = - 0.77; 95% CI: - 1.3, - 0.28) while a greater number of sutures was associated with higher ultimate failure load ( ß= 3; 95% CI: 21, 125). In human cadaveric models, the number of sutures used in triceps tendon repairs may be more important than the fixation type or number of implants for overall strength. If using a transosseous direct repair approach to repair triceps tendon tears, surgeons may choose to use more sutures in their repair in order to balance the risk of larger gap formation when compared to indirect repair techniques. LEVEL OF EVIDENCE: Level III.


Assuntos
Cadáver , Técnicas de Sutura , Traumatismos dos Tendões , Humanos , Fenômenos Biomecânicos , Âncoras de Sutura , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia
18.
Micron ; 183: 103648, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38723296

RESUMO

The mallard webbed foot represents an exemplary model of biomechanical efficiency in avian locomotion. This study delves into the intricate material assembly and tendon morphology of the mallard webbed foot, employing both macroscopic and microscopic analyses. Through histological slices and scanning electron microscopy (SEM), we scrutinized the coupling assembly of rigid and flexible materials such as skin, tendon, and bone, while elucidating the biomechanical functions of tendons across various segments of the tarsometatarsophalangeal joint (TMTPJ). The histological examination unveiled a complex structural hierarchy extending from the external integument to the skeletal framework. Notably, the bone architecture, characterized by compact bone and honeycombed trabeculae, showcases a harmonious blend of strength and lightweight design. Tendons, traversing the phalangeal periphery, surrounded by elastic fibers, collagen fibers, and fat tissue. Fat chambers beneath the phalanx, filled with adipocytes, provide effective buffering, enabling the phalanx to withstand gravity, provide support, and facilitate locomotion. Furthermore, SEM analysis provided insights into the intricate morphology and arrangement of collagen fiber bundles within tendons. Flexor tendons in proximal and middle TMTPJ segments adopt a wavy-type, facilitating energy storage and release during weight-bearing activities. In contrast, distal TMTPJ flexor tendons assume a linear-type, emphasizing force transmission across phalangeal interfaces. Similarly, extensor tendons demonstrate segment-specific arrangements tailored to their respective biomechanical roles, with wavy-type in proximal and distal segments for energy modulation and linear-type in middle segments for enhanced force transmission and tear resistance. Overall, our findings offer a comprehensive understanding of the mallard webbed foot's biomechanical prowess, underscoring the symbiotic relationship between material composition, tendon morphology, and locomotor functionality. This study not only enriches our knowledge of avian biomechanics but also provides valuable insights for biomimetic design and tissue engineering endeavors.


Assuntos
, Microscopia Eletrônica de Varredura , Tendões , Animais , Tendões/fisiologia , Tendões/ultraestrutura , Tendões/anatomia & histologia , Fenômenos Biomecânicos , Pé/fisiologia , Pé/anatomia & histologia , Locomoção/fisiologia
19.
Ann Med ; 56(1): 2337871, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38738394

RESUMO

Tendons are fibroblastic structures that link muscle and bone. There are two kinds of tendon injuries, including acute and chronic. Each form of injury or deterioration can result in significant pain and loss of tendon function. The recovery of tendon damage is a complex and time-consuming recovery process. Depending on the anatomical location of the tendon tissue, the clinical outcomes are not the same. The healing of the wound process is divided into three stages that overlap: inflammation, proliferation, and tissue remodeling. Furthermore, the curing tendon has a high re-tear rate. Faced with the challenges, tendon injury management is still a clinical issue that must be resolved as soon as possible. Several newer directions and breakthroughs in tendon recovery have emerged in recent years. This article describes tendon injury and summarizes recent advances in tendon recovery, along with stem cell therapy, gene therapy, Platelet-rich plasma remedy, growth factors, drug treatment, and tissue engineering. Despite the recent fast-growing research in tendon recovery treatment, still, none of them translated to the clinical setting. This review provides a detailed overview of tendon injuries and potential preclinical approaches for treating tendon injuries.


Assuntos
Terapia Genética , Traumatismos dos Tendões , Engenharia Tecidual , Cicatrização , Traumatismos dos Tendões/terapia , Traumatismos dos Tendões/fisiopatologia , Humanos , Cicatrização/fisiologia , Animais , Engenharia Tecidual/métodos , Terapia Genética/métodos , Plasma Rico em Plaquetas , Tendões , Transplante de Células-Tronco/métodos , Peptídeos e Proteínas de Sinalização Intercelular/uso terapêutico , Peptídeos e Proteínas de Sinalização Intercelular/metabolismo
20.
Bull Hosp Jt Dis (2013) ; 82(2): 146-153, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38739663

RESUMO

Surgical management of the subscapularis tendon is critical to a successful outcome following anatomic total shoulder arthroplasty. However, the optimal surgical technique for adequate exposure of the glenohumeral joint while mini-mizing complications resulting from subscapularis tendon dysfunction continues to be controversial. Common surgical techniques for the management of the subscapularis tendon include tenotomy, peeling, sparing, and lesser tuberosity oste-otomy. Despite a number of published studies comparing these techniques, no consensus has been reached regarding optimal management. This article reviews the extensive literature on the biomechanical, radiologic, and clinical outcomes of each technique, including recently published comparison studies.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Resultado do Tratamento , Fenômenos Biomecânicos , Tenotomia/métodos , Recuperação de Função Fisiológica , Tendões/cirurgia , Amplitude de Movimento Articular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...