1.
J Pharm Biomed Anal ; 251: 116454, 2024 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-39217703

RESUMO

Low volume sampling technologies have gained popularity as they are minimally invasive, reduce patient burden, enhance population diversity, and have the potential to facilitate decentralized clinical trials. Herein, we validated a Gyrolab assay to measure soluble Mucosal Addressin Cell Adhesion Molecule 1 (sMAdCAM-1) in dried blood samples collected using two low volume sampling devices, Mitra and Tasso-M20. This validated assay was implemented in a proof-of-concept study to compare three low volume sampling devices (Mitra, Tasso-M20 and TassoOne Plus) with serum collected via venipuncture from healthy volunteers receiving etrolizumab. We observed significantly higher concentration of sMAdCAM-1 in dried blood samples collected using Mitra and Tasso-M20 compared to serum in some paired samples, which was attributed to interference from the dried blood extraction buffer. To mitigate this interference, samples required substantial dilution into the appropriate buffer, which negatively impacted the detectability of sMAdCAM-1 with the Gyrolab assay. By employing the Quanterix single molecule array (Simoa), known for its superior assay sensitivity, the interference was minimized in the diluted samples. Both liquid blood collected in TassoOne Plus and dried blood collected using Mitra and Tasso-M20 demonstrated great concordance with serum for sMAdCAM-1 measurement. However, a bias was observed in Mitra dried blood samples, presumably due to the different sample collection sites in comparison with venipuncture and Tasso devices. Our study highlights the potential of low volume sampling technologies for biomarker analysis, and underscores the importance of understanding the challenges and limitations of these technologies before integrating them into clinical studies.


Assuntos
Biomarcadores , Teste em Amostras de Sangue Seco , Humanos , Teste em Amostras de Sangue Seco/métodos , Teste em Amostras de Sangue Seco/instrumentação , Biomarcadores/sangue , Anticorpos Monoclonais Humanizados/sangue , Voluntários Saudáveis , Estudo de Prova de Conceito , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/instrumentação
2.
Molecules ; 29(17)2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39274988

RESUMO

Despite a higher safety profile compared to vitamin K antagonists, rivaroxaban therapy is still connected with multiple adverse effects, such as a high risk of bleeding. Thus, therapeutic drug monitoring (TDM) of rivaroxaban concentrations is suggested. An alternative to plasma samples can be dried blood spots (DBS), which minimize the cost of sample storage and transport. In this study, we developed a UPLC-MS/MS method for the analysis of rivaroxaban in DBS and plasma samples. Chromatographic separation was achieved on a Zorbax Eclipse Plus C18 column (2.1 × 100 mm; 3.5 µm, Agilent Technologies Inc., Santa Clara, CA, USA) with a mobile phase consisting of water and acetonitrile, both containing 0.1% formic acid. The analytes were detected using a positive ionization mode by multiple reaction monitoring. We validated the method according to ICH guidelines. The precision and accuracy were satisfactory. Extraction recovery was approximately 57% and 66% for DBS and plasma samples, respectively. A high correlation between rivaroxaban concentrations in plasma and DBS samples collected from patients was confirmed with Deming regression. The suitability of both sampling techniques for the rivaroxaban TDM was also verified by Bland-Altman plots based on DBS-predicted and observed plasma concentrations. In addition, we found a significant relationship between rivaroxaban concentrations and coagulation parameters, including prothrombin time (PT) and international normalized ratio (INR).


Assuntos
Teste em Amostras de Sangue Seco , Monitoramento de Medicamentos , Rivaroxabana , Espectrometria de Massas em Tandem , Trombose Venosa , Rivaroxabana/sangue , Humanos , Espectrometria de Massas em Tandem/métodos , Teste em Amostras de Sangue Seco/métodos , Cromatografia Líquida de Alta Pressão/métodos , Trombose Venosa/sangue , Trombose Venosa/tratamento farmacológico , Monitoramento de Medicamentos/métodos , Inibidores do Fator Xa/sangue , Reprodutibilidade dos Testes , Espectrometria de Massa com Cromatografia Líquida
3.
Sci Rep ; 14(1): 21655, 2024 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-39289450

RESUMO

Using a modified proximity extension assay, total and immunoglobulin (Ig) class-specific anti-SARS-CoV-2 antibodies were sensitively and conveniently detected directly from ø1.2 mm discs cut from dried blood and saliva spots (DBS and DSS) without the need for elution. For total Ig detection, antigen probes were prepared by conjugating recombinant spike protein subunit 1 (S1-RBD) to a pair of oligonucleotides. To detect isotype-specific antibody reactivity, one antigen probe was replaced with oligonucleotide-conjugated antibodies specific for antibody isotypes. Binding of pairs of oligonucleotide-conjugated probes to antibodies in patient samples brings oligonucleotides in proximity. An added DNA polymerase uses a transient hybridization between the oligonucleotides to prime synthesis of a DNA strand, which serves as a DNA amplicon that is quantified by real-time PCR. The S1-RBD-specific IgG, IgM, and IgA antibodies in DBS samples collected over the course of a first and second vaccination exhibited kinetics consistent with previous reports. Both DBS and DSS collected from 42 individuals in the autumn of 2023 showed significant level of total S1-RBD antibodies with a correlation of R = 0.70. However, levels in DSS were generally 10 to 100-fold lower than in DBS. Anti-S1-RBD IgG and IgA in DSS demonstrated a correlation of R = 0.6.


Assuntos
Anticorpos Antivirais , COVID-19 , Imunoglobulina A , Imunoglobulina G , Imunoglobulina M , SARS-CoV-2 , Saliva , Humanos , Saliva/imunologia , SARS-CoV-2/imunologia , Imunoglobulina M/imunologia , Imunoglobulina M/sangue , Imunoglobulina G/imunologia , Imunoglobulina G/sangue , Imunoglobulina A/imunologia , Imunoglobulina A/sangue , Anticorpos Antivirais/imunologia , Anticorpos Antivirais/sangue , COVID-19/imunologia , COVID-19/diagnóstico , COVID-19/virologia , Glicoproteína da Espícula de Coronavírus/imunologia , Teste em Amostras de Sangue Seco/métodos
4.
Scand J Clin Lab Invest ; 84(5): 326-335, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39225029

RESUMO

Breast cancer (BC) is among the most commonly diagnosed cancers. Besides mammography, breast ultrasonography and the routinely monitored protein markers, the variations of small molecular metabolites in blood may be of great diagnostic value. This study aimed to quantify specific metabolite markers with potential application in BC detection. The study enrolled 50 participants, 25 BC patients and 25 healthy controls (CTRL). Dried blood spots (DBS) were utilized as biological media and were quantified via a simplified liquid chromatography tandem mass spectrometry (LC-MS/MS) method, used in expanded newborn screening. The targeted metabolomic analysis included 12 amino acids and 32 acylcarnitines. Statistical analysis revealed a significant variation of metabolic profiles between BC patients and CTRL. Among the 44 metabolites, 18 acylcarnitines and 10 amino acids remained significant after Bonferroni correction, showing increase or decrease and enabled classification of BC patients and CTRL. The well-established LC-MS/MS protocol could provide results within few minutes. Therefore, the combination of an easy-to-handle material-DBS and LC-MS/MS protocol could facilitate BC screening/diagnosis and in the next step applied to other cancer patients, as well.


Assuntos
Neoplasias da Mama , Carnitina , Teste em Amostras de Sangue Seco , Metabolômica , Espectrometria de Massas em Tandem , Humanos , Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico , Feminino , Teste em Amostras de Sangue Seco/métodos , Metabolômica/métodos , Pessoa de Meia-Idade , Carnitina/sangue , Carnitina/análogos & derivados , Estudos de Casos e Controles , Adulto , Cromatografia Líquida , Biomarcadores Tumorais/sangue , Idoso , Aminoácidos/sangue , Metaboloma
6.
Bioanalysis ; 16(12): 603-613, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39185792

RESUMO

Aim: This study aimed to develop and validate a GC-NPD method for quantifying topiramate (TPM) in capillary dried plasma spots (DPS).Materials & methods: Extraction involved three 6 mm DPS with albumin 0.1%, alkaline liquid extraction with tert-Butyl methyl ether and TMAH methylation. The method was validated and applied to 15 paired samples of capillary DPS and venous plasma from chemical dependency patients.Results: The method was linear from 1 to 50 µg/ml (r >0.99), precise (CV% 3.62-8.29%) accurate (98.1-107.7%). TPM stability was confirmed in DPS stored at 4, 23 and 45°C for 21 days. DPS TPM measurements were highly correlated plasma concentrations (rs = 0.96), representing on average 102% of the venous plasma measurements.Conclusion: The method was fully validated, demonstrating potential for clinical application.


[Box: see text].


Assuntos
Teste em Amostras de Sangue Seco , Topiramato , Topiramato/sangue , Humanos , Teste em Amostras de Sangue Seco/métodos , Cromatografia Gasosa/métodos , Frutose/análogos & derivados , Frutose/sangue
7.
J Mass Spectrom ; 59(9): e5081, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39187037

RESUMO

Apixaban, a direct oral anticoagulant drug (DOAC), typically does not require routine therapeutic drug monitoring (TDM), yet recent guidelines propose its use in specific clinical scenarios. While various antifactor Xa (anti-FXa) chromogenic assays serve as useful proxies for measuring plasma exposure to apixaban in emergencies, they lack specificity compared with chromatographic methods. This research project is intended to the development and validation of a standardized protocol of liquid chromatography-tandem mass spectrometry (LC-MS/MS) in conformity with the ICH guidelines M10 for the measurement of apixaban in both plasma and dried plasma spots (DPSs). Samples preparation included protein precipitation after the addition of a deuterated internal standard (IS), and the chromatographic separation was carried out on a Thermo Scientific™ Accucore™ Polar Premium column (50 mm × 2.1 mm, i.d. 2.6 m). The newly developed LC-MS/MS method for apixaban mesurement from both plasma and DPS resulted linear over a wide concentration range (31.25-500 ng/mL), accurate, and reproducible without matrix effects, allowing for specific and rapid quantification. Stability was assessed on quality controls and a real sample, allowing the setting up of a robust TDM protocol that was applied to five anonymized plasma samples obtained from adult patients undergoing apixaban treatment at steady-state. In conclusion our novel LC-MS/MS method is adequate for accurate apixaban quantitation from both plasma and DPS matrixes, and may thus facilitate the guidelines suggested implementation of apixaban TDM, even in peripheral hospitals through shipment of DPS at reference laboratories.


Assuntos
Teste em Amostras de Sangue Seco , Monitoramento de Medicamentos , Inibidores do Fator Xa , Pirazóis , Piridonas , Espectrometria de Massas em Tandem , Piridonas/sangue , Espectrometria de Massas em Tandem/métodos , Humanos , Pirazóis/sangue , Pirazóis/farmacocinética , Monitoramento de Medicamentos/métodos , Teste em Amostras de Sangue Seco/métodos , Reprodutibilidade dos Testes , Cromatografia Líquida/métodos , Inibidores do Fator Xa/sangue , Inibidores do Fator Xa/farmacocinética , Limite de Detecção , Modelos Lineares
8.
Forensic Sci Int ; 363: 112173, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39111057

RESUMO

This study details trends in direct alcohol biomarker concentrations from civil cases within the United Kingdom (UK). Our subject cohort in this study related to family law litigation, where an individual was subject to an alcohol monitoring order by the court. This monitoring was conducted by quantification of alcohol biomarkers Phosphatidlyethanol (PEth) in dried blood spots (DBS) and Ethyl Glucuronide (EtG) and Ethyl Palmitate (EtPa) from hair segments. In total 298 PEth cases predominantly from the South East of England during the period July 2022 to August 2023 were analysed for alcohol biomarkers in DBS and hair. Subjects alcohol intake was classified as abstinence/low alcohol consumption, moderate or excessive alcohol consumption, based on a combination of Society for Hair Testing and PEth Net guidelines. Our results indicate that 33 % of PEth concentrations were consistent with excessive alcohol use (>200 ng/mL DBS), with 36 % consistent with social or moderate alcohol use (20-200 ng/mL DBS). In relation to EtG and EtPa 23 % and 31 % of subjects were classified as excessive alcohol users respectively. This study indicates that DBS sampling of PEth is a more sensitive predictor of alcohol use, in particular, at differentiating between moderate and excessive alcohol use compared to EtG and EtPa testing in hair. The authors suggest that increased frequency in the sampling of PEth in DBS (multiple occasions per month) may provide a more accurate assessment and simplification of the interpretation criteria of alcohol patterns rather than the combined hair testing and DBS sampling that are typically requested by UK courts.


Assuntos
Consumo de Bebidas Alcoólicas , Biomarcadores , Glucuronatos , Glicerofosfolipídeos , Cabelo , Humanos , Glucuronatos/análise , Cabelo/química , Biomarcadores/sangue , Biomarcadores/análise , Masculino , Feminino , Inglaterra , Adulto , Consumo de Bebidas Alcoólicas/legislação & jurisprudência , Glicerofosfolipídeos/sangue , Teste em Amostras de Sangue Seco , Pessoa de Meia-Idade , Adulto Jovem , Detecção do Abuso de Substâncias/métodos , Adolescente , Ácidos Palmíticos
9.
Int J Mol Sci ; 25(16)2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39201589

RESUMO

Hypoxic-ischemic encephalopathy (HIE) is a severe neurological disorder caused by perinatal asphyxia with significant consequences. Early recognition and intervention are crucial, with therapeutic hypothermia (TH) being the primary treatment, but its efficacy depends on early initiation of treatment. Accurately assessing the HIE severity in neonatal care poses challenges, but omics approaches have made significant contribution to understanding its complex pathophysiology. Our study further explores the impact of HIE on the blood metabolome over time and investigated changes associated with hypothermia's therapeutic effects. Using a rat model of hypoxic-ischemic brain injury, we comprehensively analyzed dried blood spot samples for fat-soluble compounds using HPLC-MS. Our research shows significant changes in the blood metabolome after HIE, with a particularly rapid recovery of lipid metabolism observed. Significant changes in lipid metabolites were observed after 3 h of HIE, including increases in ceramides, carnitines, certain fatty acids, phosphocholines, and phosphoethanolamines, while sphingomyelins and N-acylethanolamines (NAEs) decreased (p < 0.05). Furthermore, NAEs were found to be significant features in the OPLS-DA model for HIE diagnosis, with an area under the curve of 0.812. TH showed a notable association with decreased concentrations of ceramides. Enrichment analysis further corroborated these observations, showing modulation in several key metabolic pathways, including arachidonic acid oxylipin metabolism, eicosanoid metabolism via lipooxygenases, and leukotriene C4 synthesis deficiency. Our study reveals dynamic changes in the blood metabolome after HIE and the therapeutic effects of hypothermia, which improves our understanding of the pathophysiology of HIE and could lead to the development of new rapid diagnostic approaches for neonatal HIE.


Assuntos
Animais Recém-Nascidos , Modelos Animais de Doenças , Teste em Amostras de Sangue Seco , Hipóxia-Isquemia Encefálica , Metaboloma , Animais , Hipóxia-Isquemia Encefálica/metabolismo , Hipóxia-Isquemia Encefálica/sangue , Ratos , Teste em Amostras de Sangue Seco/métodos , Metabolismo dos Lipídeos , Hipotermia Induzida/métodos , Ratos Sprague-Dawley , Metabolômica/métodos , Masculino , Ceramidas/sangue , Ceramidas/metabolismo , Feminino
11.
J Infect Public Health ; 17(9): 102500, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39173560

RESUMO

BACKGROUND: Monitoring adherence presents a challenge in adolescents and it is prudent to explore several options for determining their level of adherence. This study sought to determine ART adherence levels in adolescents and young adults (on a tenofovir-containing regimen) failing ART as measured by self-reports, pill counts and DBS tenofovir concentrations and to compare levels of agreement among the methods and determine the ability of each method to predict virological suppression. METHODS: This was a cohort study involving 107 adolescents and young adults between 10 and 24 years failing ART with viral load > 400copies/ml at enrolment. Pill count (PC) records, self-reports (SR) and DBS tenofovir concentrations (done by liquid Chromatography with tandem mass spectrometry (LC-MS/MS)) were used to determine adherence in adolescent participants failing ART in Harare. The latter was used as the reference method with a cut-off of 64 ng/ml. Determination of DBS tenofovir concentrations was also performed to rule out inadequate viral response due to low cumulative drug exposure despite high adherence (≥90 %). Longitudinal analysis was performed to determine the correlation of viral loads (VL) with adherence. The Kappa (k) coefficient was used to evaluate the level of agreement among the 3 methods. RESULTS: Poor level of agreement was found between PC records and DBS tenofovir concentrations (k = -0.115). Moderate agreement was found between DBS and SR methods (k = 0.0557). Slight agreement was found between PC and SR methods (k = 0.0078). Adherence was dependent on age at HIV diagnosis (p = 0.0184) and ART initiation (p = 0.0265). Participants who were adherent were six times more likely to be suppressed at end point than their non-adherent counterparts (OR=5.7 CI 2.1 - 16.5, p < 0.0001). CONCLUSIONS: Self-reported measure of adherence and pill counts exhibited poor agreement with the reference method used i.e. DBS tenofovir concentrations and are thus not effective methods of predicting virological suppression. TRIAL IDENTIFICATION: Participants in the present study were a subset of those in the PESU intervention ClinicalTrials.gov Identifier: NCT02833441.


Assuntos
Fármacos Anti-HIV , Infecções por HIV , Adesão à Medicação , Autorrelato , Tenofovir , Carga Viral , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Adulto Jovem , Fármacos Anti-HIV/uso terapêutico , Cromatografia Líquida/métodos , Estudos de Coortes , Teste em Amostras de Sangue Seco/métodos , Farmacorresistência Viral , Infecções por HIV/tratamento farmacológico , Adesão à Medicação/estatística & dados numéricos , Espectrometria de Massas em Tandem/métodos , Tenofovir/uso terapêutico , Falha de Tratamento , Carga Viral/efeitos dos fármacos , Zimbábue
12.
Artigo em Inglês | MEDLINE | ID: mdl-39089063

RESUMO

Homocysteine, methionine, methylmalonic acid and 2-methylcitric acid are clinically relevant markers in the methionine, propionate, and cobalamin metabolism. This study aimed to develop and validate an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneously determining total homocysteine, methionine, methylmalonic acid and 2-methylcitric acid in dried blood spots. Three 3.2 mm discs were punched from each calibrator, quality control, and sample dried blood spot into a 96-well U-plate. Each sample was spiked with internal standards and extracted. Then the supernatant was transferred to another 96-well U-plate. After nitrogen drying, the dried residues were reconstituted, centrifuged, and the resulting supernatant was transferred to another 96-well plate for analysis. The method was performed using UPLC-MS/MS within 3 min, validated according to guidance documents, and applied to 72 samples from confirmed patients with methionine, propionate, and cobalamin metabolism disorders. The UPLC-MS/MS method provided satisfactory separation of the four analytes. The R2 values were ≥ 0.9937 for all analytes. The recoveries ranged from 94.17 to 114.29 %, and the coefficients of variation for intraday and interday precision were 0.19 % to 5.23 % and 1.02 % to 6.89 %, respectively. No significant carry-over was detected for the four analytes, and most of confirmed samples exhibited biomarker patterns characteristic of the relevant disorders. A simple and fast UPLC-MS/MS method was successfully developed, validated, and applied to clinical samples for the simultaneous determination of total homocysteine, methionine, methylmalonic acid, and 2-methylcitric acid in dried blood spots.


Assuntos
Citratos , Teste em Amostras de Sangue Seco , Homocisteína , Limite de Detecção , Metionina , Ácido Metilmalônico , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Homocisteína/sangue , Homocisteína/análogos & derivados , Ácido Metilmalônico/sangue , Ácido Metilmalônico/análogos & derivados , Teste em Amostras de Sangue Seco/métodos , Reprodutibilidade dos Testes , Metionina/sangue , Metionina/análogos & derivados , Metionina/química , Modelos Lineares , Citratos/sangue , Citratos/química , Masculino , Feminino , Pré-Escolar
13.
Int J Mol Sci ; 25(16)2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39201447

RESUMO

Ganciclovir (GCV) and its prodrug valganciclovir (VGCV) are antiviral medications primarily used to treat infections caused by cytomegalovirus (CMV), particularly in immunocompromised individuals such as solid organ transplant (SOT) recipients. Therapy with GCV is associated with significant side effects, including bone marrow suppression. Therefore, therapeutic drug monitoring (TDM) is mandatory for an appropriate balance between subtherapeutic and toxic drug levels. This study aimed to develop and validate three novel methods based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) for GCV determination in serum (reference methodology), dried serum spots (DSS), and VAMS-Mitra™ devices. The methods were optimized and validated in the 0.1-25 mg/L calibration range. The obtained results fulfilled the EMA acceptance criteria for bioanalytical method validation. Assessment of DSS and VAMS techniques extended GCV stability to serum for up to a minimum of 49 days (at room temperature, with desiccant). Developed methods were effectively evaluated using 80 clinical serum samples from pediatric renal transplant recipients. Obtained samples were used for DSS, and dried serum VAMS samples were manually generated in the laboratory. The results of GCV determination using serum-, DSS- and VAMS-LC-MS/MS methods were compared using regression analysis and bias evaluation. The conducted statistical analysis confirmed the interchangeability between developed assays. The DSS and VAMS samples are more accessible and stable during storage, transport and shipment than classic serum samples.


Assuntos
Antivirais , Teste em Amostras de Sangue Seco , Monitoramento de Medicamentos , Ganciclovir , Espectrometria de Massas em Tandem , Humanos , Monitoramento de Medicamentos/métodos , Teste em Amostras de Sangue Seco/métodos , Espectrometria de Massas em Tandem/métodos , Ganciclovir/análogos & derivados , Ganciclovir/sangue , Ganciclovir/uso terapêutico , Antivirais/sangue , Antivirais/uso terapêutico , Cromatografia Líquida/métodos , Infecções por Citomegalovirus/sangue , Infecções por Citomegalovirus/tratamento farmacológico , Valganciclovir/uso terapêutico , Valganciclovir/sangue , Criança
14.
Brain Behav Immun ; 120: 545-553, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38971206

RESUMO

Dried blood spots (DBS) provide a minimally invasive method to assess inflammatory markers and can be collected remotely at-home or in-person in the lab. However, there is a lack of methodological information comparing these different collection methods and in older adults. We investigated the feasibility (including adherence, yield, quality, and participant preferences) and measurement properties (reliability, validity) of remotely collected DBS inflammatory markers in older adults. Participants (N = 167, mean age = 72, range: 60-96 years) collected their own DBS (finger prick on filter paper) during three remote interviews over âˆ¼ 6 months. Within 4-5 days on average of their last remote interview, a subset of 41 participants also attended an in-person lab visit that included a researcher-collected DBS sample, venous blood draw, and survey to assess participant preferences of DBS collection. DBS and venous blood were assayed for CRP, IL-6, and TNF-α. Adherence: 98% of expected DBS samples (493 out of 501) were completed and mailed back to the lab. Yield: 97% of DBS samples were sufficient for all assays. Quality: On average, 0.80 fewer optimal spots (60uL of blood that filled the entire circle) were obtained remotely vs. in-person (p = 0.013), but the number of useable or better spots (at least 30-40uL of blood) did not differ (p = 0.89). Preference: A slight majority of participants (54%) preferred in-person DBS collection. Reliability: DBS test-retest reliabilities were good: CRP (ICC = 0.74), IL-6 (ICC = 0.76), and TNF-α (ICC = 0.70). Validity: Inflammatory levels from DBS correlated strongly with levels from venous blood (r = 0.60-0.99) and correlated as expected with sociodemographic and physical health and function variables. Older adults can remotely collect their own DBS to acquire reliable and valid inflammatory data. Remote DBS collection is highly feasible and may allow for inflammatory markers to be assessed in larger, more representative samples than are possible with lab- or clinic-based research designs.


Assuntos
Biomarcadores , Teste em Amostras de Sangue Seco , Inflamação , Humanos , Idoso , Feminino , Masculino , Pessoa de Meia-Idade , Teste em Amostras de Sangue Seco/métodos , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Reprodutibilidade dos Testes , Inflamação/sangue , Interleucina-6/sangue , Fator de Necrose Tumoral alfa/sangue , Estudos de Viabilidade , Proteína C-Reativa/análise , Proteína C-Reativa/metabolismo , Coleta de Amostras Sanguíneas/métodos
16.
Artigo em Inglês | MEDLINE | ID: mdl-39059319

RESUMO

The ecological impact of biological, chemical, and analytical research practices, including toxic reagents and biohazardous waste, has led to the development of alternative sampling and extraction techniques for bioanalysis. Microsampling (sample volume < 50 µL) aligns with the 3Rs principle, allowing multiple sampling points from the same animal at different time points and improving animal welfare. A bioanalytical method was developed to investigate factors related to bioanalytical challenges and the implementation of microsampling techniques. An LC-MS/MS method for Volumetric Absorptive Microsampling (VAMS), 20 µL, was developed for quantifying Lurasidone using a liquid-liquid extraction technique. The method uses a C18, Phenomenex column for chromatographic separation and a mobile phase composition of Methanol, Acetonitrile, and Water with 0.1 % HFBA. The method was validated over a concentration range of 5.0 to 1200.0 ng/mL and achieved acceptable precision and accuracy. The recovery for analyte from VAMS was approximately 40% at four different concentrations and is consistent (%CV < 15), with no significant differences among HCT levels. The matrix factor ranged between 85.00 and 115.00 %, showing no substantial issues with reduced or enhanced signal. The stability data showed no significant degradation of LUR in VAMS samples when stored at room temperature for 15 days. The newly established method for Lurasidone confirmed the use of VAMS sampling method and its analysis on LC-MS/MS. Further, the data obtained from microsampling techniques was compared with conventional (plasma) technique, as proof-of-concept, and it confirms the agreement between the two methods. The study supports the advantages of microsampling in protecting the environment and animals while maintaining scientific judgement.


Assuntos
Teste em Amostras de Sangue Seco , Cloridrato de Lurasidona , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Cloridrato de Lurasidona/sangue , Cloridrato de Lurasidona/química , Teste em Amostras de Sangue Seco/métodos , Animais , Reprodutibilidade dos Testes , Cromatografia Líquida/métodos , Modelos Lineares , Limite de Detecção , Extração Líquido-Líquido/métodos , Espectrometria de Massa com Cromatografia Líquida
17.
Talanta ; 278: 126491, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38955103

RESUMO

BACKGROUND: To date, clinical laboratories face challenges in quantifying retinol from DBS samples. Disputes arise throughout the whole detection process, encompassing the storage condition, the release strategy as well as the selection of internal standards. METHODS: We incubated DBS with ascorbic acid solution. Then, retinol-d4 in acetonitrile was introduced to incorporate isotopic internal standard and promote protein precipitation. Afterward, sodium carbonate solution was added to ionize cytochromes (such as bilirubin), which amplified the difference of their hydrophobicity to retinol. Subsequently, cold-induced phase separation could be facilitated to separate retinol from the impurities. In the end, the upper layer was injected for LC-MS/MS analysis. RESULTS: By comparing the detected retinol content in whole blood and DBS samples prepared from the same volume, we confirmed the established pretreatment was capable to extract most of retinol from DBS (recovery >90 %). Thereafter, we verified that within DBS, retinol possessed satisfying stability without antioxidation. Indoor-light exposure and storage duration would not cause obvious degradation (<10 %). Following systematic validation, the established method well met the criteria outlined in the relevant guidelines. After comparing with detected DBS results to the paired plasma samples, 54 out of 60 met the acceptance limit for cross-validation of ±20 %. CONCLUSIONS: We realized precise quantification of retinol from one 3.2 mm DBS disc. By circumventing conventional antioxidation, liquid-liquid/solid-phase extraction and organic solvent evaporation, the pretreatment could be completed within 15 min consuming only minimal amounts of low-toxicity chemicals (ascorbic acid, acetonitrile, and sodium carbonate). We expect this contribution holds the potential to significantly facilitate the evaluation of patients' vitamin A status by using DBS samples in the future.


Assuntos
Teste em Amostras de Sangue Seco , Espectrometria de Massa com Cromatografia Líquida , Espectrometria de Massas em Tandem , Vitamina A , Humanos , Teste em Amostras de Sangue Seco/métodos , Espectrometria de Massa com Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Vitamina A/sangue , Vitamina A/isolamento & purificação
18.
J Proteome Res ; 23(8): 3585-3597, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-38950347

RESUMO

The use of protein biomarkers in blood for clinical settings is limited by the cost and accessibility of traditional venipuncture sampling. The dried blood spot (DBS) technique offers a less invasive and more accessible alternative. However, protein stability in DBS has not been well evaluated. Herein, we deployed a quantitative LC-MS/MS system to construct proteomic atlases of whole blood, DBSs, plasma, and blood cells. Approximately 4% of detected proteins' abundance was significantly altered during blood drying into blood spots, with overwhelming disturbances in cytoplasmic fraction. We also reported a novel finding suggesting a decrease in the level of membrane/cytoskeletal proteins (SLC4A1, RHAG, DSC1, DSP, and JUP) and an increase in the level of proteins (ATG3, SEC14L4, and NRBP1) related to intracellular trafficking. Furthermore, we identified 19 temporally dynamic proteins in DBS samples stored at room temperature for up to 6 months. There were three declined cytoskeleton-related proteins (RDX, SH3BGRL3, and MYH9) and four elevated proteins (XPO7, RAN, SLC2A1, and SLC29A1) involved in cytoplasmic transport as representatives. The instability was governed predominantly by hydrophilic proteins and enhanced significantly with an increasing storage time. Our analyses provide comprehensive knowledge of both short- and long-term storage stability of DBS proteins, forming the foundation for the widespread use of DBS in clinical proteomics and other analytical applications.


Assuntos
Teste em Amostras de Sangue Seco , Estabilidade Proteica , Proteômica , Espectrometria de Massas em Tandem , Humanos , Teste em Amostras de Sangue Seco/métodos , Espectrometria de Massas em Tandem/métodos , Proteômica/métodos , Cromatografia Líquida , Proteínas Sanguíneas/análise , Proteínas Sanguíneas/química , Biomarcadores/sangue , Fatores de Tempo , Proteínas do Citoesqueleto/sangue
19.
Anal Bioanal Chem ; 416(20): 4635-4645, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38949681

RESUMO

17α-Hydroxyprogesterone (17α-OHP) quantification in dried blood spots (DBS) is essential for newborn screening for congenital adrenal hyperplasia (CAH), which is challenging due to its low physiological concentration. The high false-positive rates of immunoassays necessitate the development of more accurate methods. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers increased specificity and sensitivity, yet standardized procedures for 17α-OHP measurement are required for clinical application. A candidate reference measurement procedure (cRMP) using isotope dilution LC-MS/MS was developed for 17α-OHP quantification in DBS. By utilizing stable isotope-labeled D8-17α-OHP as an internal standard, the cRMP was optimized, covering sample preparation, calibration, and LC-MS/MS analysis. The method performance was validated across several parameters, including precision, accuracy, specificity, detection limits, and matrix effects. Clinical applicability was further assessed through the establishment of reference intervals for healthy newborns. The developed cRMP exhibited a linear range of 1.00 to 80.00 ng/mL for 17α-OHP, with detection and quantification limits of 0.14 ng/mL and 0.52 ng/mL, respectively. Inter- and intraday precision demonstrated coefficients of variation within 1.27 to 5.69%. The recovery rates and matrix effects were well within acceptable limits, ensuring method reliability. Clinical application showed distinct reference intervals for healthy newborns that were unaffected by sex but influenced by weight and gestational age. This method significantly enhances CAH diagnostic accuracy in newborns, providing a valuable tool for clinical laboratories and improving newborn screening program standardization and traceability.


Assuntos
17-alfa-Hidroxiprogesterona , Teste em Amostras de Sangue Seco , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Teste em Amostras de Sangue Seco/métodos , 17-alfa-Hidroxiprogesterona/sangue , Recém-Nascido , Cromatografia Líquida/métodos , Limite de Detecção , Padrões de Referência , Hiperplasia Suprarrenal Congênita/sangue , Hiperplasia Suprarrenal Congênita/diagnóstico , Triagem Neonatal/métodos , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Feminino , Valores de Referência
20.
J Infect Dis ; 230(1): e93-e101, 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39052716

RESUMO

BACKGROUND: The key correlate of protection of respiratory syncytial virus (RSV) vaccines and monoclonal antibodies (mAbs) is virus neutralization, measured via sera obtained through venipuncture. Dried blood obtained with a finger prick can simplify acquisition, processing, storage, and transport in trials and thereby reduce costs. In this study, we validate an assay to measure RSV neutralization in dried capillary blood. METHODS: Functional antibodies were compared between matched serum and dried blood samples from a phase 1 trial with RSM01, an investigational anti-RSV prefusion F mAb. Hep-2 cells were infected with a serial dilution of sample-virus mixture by using RSV-A2-mKate to determine the half-maximal inhibitory concentration. Stability of dried blood was evaluated over time and during temperature stress. RESULTS: Functional antibodies in dried blood were highly correlated with serum (R2 = 0.98, P < .0001). The precision of the assay for dried blood was similar to serum. The function of mAb remained stable for 9 months at room temperature and frozen dried blood samples. CONCLUSIONS: We demonstrated the feasibility of measuring RSV neutralization using dried blood as a patient-centered solution that may replace serology testing in trials against RSV or other viruses, such as influenza and SARS-CoV-2. Clinical Trials Registration. NCT05118386 (ClinicalTrials.gov).


Assuntos
Anticorpos Neutralizantes , Anticorpos Antivirais , Infecções por Vírus Respiratório Sincicial , Vírus Sincicial Respiratório Humano , Humanos , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , Vírus Sincicial Respiratório Humano/imunologia , Infecções por Vírus Respiratório Sincicial/imunologia , Teste em Amostras de Sangue Seco/métodos , Testes de Neutralização/métodos , Anticorpos Monoclonais/imunologia