Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Orthop Surg Res ; 18(1): 223, 2023 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-36945001

RESUMO

PURPOSE: The aim of this systematic review was to present the current evidence on the clinical use of single-photon emission computed tomography/computed tomography (SPECT/CT) in the evaluation of noninfected painful knees after knee arthroplasty. METHODS: Embase, PubMed, Google Scholar, Ovid, Scopus, Science Direct and the Cochrane Database of Systematic Reviews were searched from database inception to May 2022 following the PRISMA guidelines. As a primary outcome, we defined the role of SPECT/CT in the diagnostic approach to noninfected painful knee arthroplasty; as a secondary objective, we described the noninfection-related factors linked to painful knee arthroplasty. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio values and other indicators were calculated; receiver operating characteristic (ROC) curve analysis results and a summary of the areas under the curve (AUCs) from the included studies were reported. A Fagan plot, likelihood ratio plot and Deeks' funnel plot were generated and analysed. Methodological quality was assessed using the QUADAS-2 tool, and the certainty of evidence was assessed by the GRADE approach. RESULTS: A total of 493 publications were identified, of which eight met the inclusion criteria, with a final pooled sample size of 308 patients. The pooled sensitivity and specificity of SPECT/CT in diagnosing the source of pain in painful knee prostheses were 0.86 (95% CI: 0.75-0.93) and 0.90 (95% CI: 0.79-0.96), respectively, with pooled +LR and -LR values of 8.9 (95% CI: 4.11-19.19) and 0.15 (95% CI: 0.09-0.28). The pooled diagnostic odds ratio was 57.35, and the area under the curve was 0.94. SPECT/CT highly accurately identified different sources of pain, such as loosening of the prosthetic components, patellofemoral overloading, instability, malalignment of the components and degeneration of the patellofemoral compartment. The confidence of the estimates was moderate according to the GRADE approach. CONCLUSION: With demonstrated high sensitivity and specificity, as a diagnostic tool, SPECT/CT can identify the source of pain in painful knees after knee arthroplasty, particularly in cases of loosening, patellofemoral disorders and component malalignment (level of evidence III). These findings have significant clinical repercussions, such as in changing the initial diagnosis, identifying or excluding different causes of painful knee arthroplasties, guiding subsequent treatment and positively impacting the final clinical outcome. We moderately recommend the use of SPECT/CT for identifying the source of pain after knee arthroplasty according to the GRADE assessment. This review was preregistered in Prospero under code CRD42022320457.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Articulação do Joelho/cirurgia , Dor/etiologia , Sensibilidade e Especificidade , Testes Diagnósticos de Rotina/efeitos adversos
2.
Clin Nucl Med ; 48(2): 173-175, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35867987

RESUMO

ABSTRACT: A 14-year-old girl presented with right lower quadrant pain. A 99m Tc-pertechnetate scan with SPECT/CT was performed to exclude a Meckel's diverticulum. The images demonstrated focal tracer uptake in the right midabdomen, which appeared early and decreased over time. However, SPECT/CT revealed that this uptake corresponded to the right renal pelvis, which was located more inferior than expected. This case emphasizes the importance of recognizing anatomic variants that may cause focal tracer uptake, as well as leveraging an understanding of tracer kinetics to inform a diagnosis.


Assuntos
Divertículo Ileal , Pertecnetato Tc 99m de Sódio , Feminino , Humanos , Adolescente , Cintilografia , Divertículo Ileal/diagnóstico por imagem , Divertículo Ileal/complicações , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tecnécio , Pelve Renal/diagnóstico por imagem , Hemorragia Gastrointestinal/diagnóstico por imagem
3.
J Nucl Med ; 64(4): 652-658, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36207138

RESUMO

Low-dose ungated CT attenuation correction (CTAC) scans are commonly obtained with SPECT/CT myocardial perfusion imaging. Despite the characteristically low image quality of CTAC, deep learning (DL) can potentially quantify coronary artery calcium (CAC) from these scans in an automatic manner. We evaluated CAC quantification derived with a DL model, including correlation with expert annotations and associations with major adverse cardiovascular events (MACE). Methods: We trained a convolutional long short-term memory DL model to automatically quantify CAC on CTAC scans using 6,608 studies (2 centers) and evaluated the model in an external cohort of patients without known coronary artery disease (n = 2,271) obtained in a separate center. We assessed agreement between DL and expert annotated CAC scores. We also assessed associations between MACE (death, revascularization, myocardial infarction, or unstable angina) and CAC categories (0, 1-100, 101-400, or >400) for scores manually derived by experienced readers and scores obtained fully automatically by DL using multivariable Cox models (adjusted for age, sex, past medical history, perfusion, and ejection fraction) and net reclassification index. Results: In the external testing population, DL CAC was 0 in 908 patients (40.0%), 1-100 in 596 (26.2%), 100-400 in 354 (15.6%), and >400 in 413 (18.2%). Agreement in CAC category by DL CAC and expert annotation was excellent (linear weighted κ, 0.80), but DL CAC was obtained automatically in less than 2 s compared with about 2.5 min for expert CAC. DL CAC category was an independent risk factor for MACE with hazard ratios in comparison to a CAC of zero: CAC of 1-100 (2.20; 95% CI, 1.54-3.14; P < 0.001), CAC of 101-400 (4.58; 95% CI, 3.23-6.48; P < 0.001), and CAC of more than 400 (5.92; 95% CI, 4.27-8.22; P < 0.001). Overall, the net reclassification index was 0.494 for DL CAC, which was similar to expert annotated CAC (0.503). Conclusion: DL CAC from SPECT/CT attenuation maps agrees well with expert CAC annotations and provides a similar risk stratification but can be obtained automatically. DL CAC scores improved classification of a significant proportion of patients as compared with SPECT myocardial perfusion alone.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Cálcio , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único , Fatores de Risco , Angiografia Coronária/efeitos adversos
4.
Appl Radiat Isot ; 181: 110097, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35063867

RESUMO

Staff occupational radiation exposure is limited to 20 mSv annually to preclude tissue reaction and lower risk of cancer effect. Staff occupational exposure arises during the preparation, injection, and scanning of the patients. Recent studies reported that nuclear medicine personnel might exceed the annual dose limit in high workload and poor radiation protection circumstances. Therefore, an accurate estimation of the annual dose limit is recommended. The goal of this research is to calculate the cumulative external effective dose (mSv) per year for nuclear medicine physicians, technologists, and nurses at SPECT/CT department. A total of 15 staff worked in the nuclear medicine department at King Saud Medical City (KSMC), Riyadh, Saudi Arabia were evaluated for the last six years. 99mTc is used more frequently for most of the patients. The procedures include renal, cardiac scintigraphy procedures. Staff dose was quantified using calibrated thermoluminecnt dosimeters (TLD-100) with an automatic TLD reader (Harshaw 6600). Exposure to ionizing radiation was evaluated in terms of deep doses (Hp(10) were evaluated. The overall average and standard deviation of the external doses for nuclear medicine physicians, technologists' and nurses were 1.8 ± 0.7, 1.9 ± 0.6, 2.0 ± 0.9, 2.2 ± 0.8, 6.0 ± 2.8, and 3.6 ± 1.3 for the years 2015,2016,2017,2018,2019, and 2020, respectively. Technologists and nurses received higher doses of compared to the nuclear medicine physicians. Technologists and nurses involved in radionuclide preparation, patients' injection, and image acquisition. Staff annual exposure is below the annual dose limits; however, this external dose is considered high compared to the current workload.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Monitoramento de Radiação , Serviço Hospitalar de Radiologia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Adulto , Feminino , Humanos , Masculino , Dose Máxima Tolerável , Exposição Ocupacional/prevenção & controle , Recursos Humanos em Hospital , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Serviço Hospitalar de Radiologia/normas , Radiometria , Medição de Risco , Arábia Saudita , Carga de Trabalho
5.
Lymphat Res Biol ; 20(2): 144-152, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34415778

RESUMO

Background: In patients with secondary upper limb lymphedema, positive correlations have been observed between the dermal back flow (DBF) type and visualization of lymph nodes around the clavicle, between the former and the lymph flow pathway type, and between the latter and the visualization of lymph nodes around the clavicle when using single photon-emission computed tomography/computed tomography/lymphoscintigraphy (SPECT-CT LSG). Methods and Results: We analyzed the associations between the visualization of inguinal lymph nodes, the lymph flow pathway type, and the DBF type using SPECT-CT LSG in 81 patients with unilateral secondary lower limb lymphedema by statistical analysis using Fisher's exact test. We revealed that the lymph flow pathways in the lower limb can be classified into nine types because the type in the lower leg is not always equal to the type in the thigh. Associations were observed between the visualization of inguinal lymph nodes and types of DBF (p < 0.01), between the types of lymph flow pathway in the thighs and visualization of the inguinal lymph nodes (p = 0.02), and between the lymph flow pathway types in the thighs and lower legs (p < 0.01). Conclusion: Detriment to the superficial lymph flow pathways in the lower limb appears to usually start from the proximal side, and deep pathways are considered to become dominant from a compensatory perspective as lymphedema severity increases.


Assuntos
Linfedema , Linfocintigrafia , Humanos , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/patologia , Sistema Linfático/diagnóstico por imagem , Sistema Linfático/patologia , Linfedema/diagnóstico por imagem , Linfedema/etiologia , Linfedema/patologia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos
7.
Clin Nucl Med ; 46(3): 238-239, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33323737

RESUMO

ABSTRACT: A 58-year-old man with progressive dyspnea and recurrent extensive left-sided pleural effusion underwent pulmonary ventilation/perfusion SPECT/CT, which showed a pronounced mismatched perfusion deficit of the entire, normally ventilated left lung. As unilateral perfusion deficits of an entire lobe are generally not due to pulmonary embolism, further CT angiography and cardiac MRI were conducted. These examinations revealed high-grade left pulmonary vein stenosis (PVS) caused by pulmonary vein isolation performed for atrial fibrillation 3 and 4 years earlier. Thus, in addition to, for example, neoplastic processes or pulmonary congenital vascular abnormalities, PVS must be considered as a differential diagnosis and possible pitfall in ventilation/perfusion SPECT/CT in dyspneic patients with prior pulmonary vein isolation.


Assuntos
Imagem de Perfusão/efeitos adversos , Embolia Pulmonar/diagnóstico por imagem , Ventilação Pulmonar , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Estenose de Veia Pulmonar/etiologia , Humanos , Masculino , Pessoa de Meia-Idade
8.
Radiol Med ; 124(8): 768-776, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30771217

RESUMO

Hybrid imaging procedures such as single-photon emission computed tomography/computed tomography (SPECT/CT) and positron emission tomography/computed tomography (PET/CT) showed a rapid diffusion in recent years because of their high sensitivity, specificity, and accuracy, due to a more accurate localization and definition of scintigraphic findings. However, hybrid systems inevitably lead to an increase in patient radiation exposure because of the added CT component. Effective doses due to the radiopharmaceuticals can be estimated by multiplying the administered activities by the effective dose coefficients, while for the CT component the dose-length product can be multiplied by a conversion coefficient k. However, the effective dose value is subject to a high degree of uncertainty and must be interpreted as a broad, generic estimate of biologic risk. Although the effective dose can be used to estimate and compare the risk of radiation exposure across multiple imaging techniques, clinicians should be aware that it represents a generic evaluation of the risk derived from a given procedure to a generic model of the human body. It cannot be applied to a single individual and should not be used for epidemiologic studies or the estimation of population risks due to the inherent uncertainties and oversimplifications involved. Practical ways to reduce radiation dose to patients eligible for hybrid imaging involve adjustments to both the planning phase and throughout the execution of the study. These methods include individual justification of radiation exposure, radiopharmaceutical choice, adherence to diagnostic reference levels (DLR), patient hydration and bladder voiding, adoption of new technical devices (sensitive detectors or collimators) with new reconstruction algorithms, and implementation of appropriate CT protocols and exposure parameters.


Assuntos
Imagem Multimodal/efeitos adversos , Medicina Nuclear , Doses de Radiação , Exposição à Radiação/prevenção & controle , Compostos Radiofarmacêuticos/efeitos adversos , Humanos , Imagem Multimodal/métodos , Imagem Multimodal/estatística & dados numéricos , Imagem Multimodal/tendências , Medicina Nuclear/estatística & dados numéricos , Medicina Nuclear/tendências , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/tendências , Editoração/estatística & dados numéricos , Editoração/tendências , Compostos Radiofarmacêuticos/administração & dosagem , Risco , Sensibilidade e Especificidade , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/tendências , Tomografia Computadorizada por Raios X/efeitos adversos
9.
Clin Nucl Med ; 43(11): 864-866, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30222684

RESUMO

Neuroendocrine tumors have a propensity to metastasize, but rarely to the orbits. A 69-year-old woman with history of neuroendocrine tumor of pancreatic primary underwent routine follow-up In-pentetreotide (OctreoScan) imaging, with 24-hour whole-body planar images showing subtle right periorbital tracer uptake that localized to extraocular muscles on subsequent SPECT/CT. Orbital MRI further defined the location of these highly suspicious orbital metastases, which were treated with external radiation, with follow-up MRI showing decreased size of the orbital metastases. Early identification and treatment of orbital metastases is critical to help preserve vision and quality of life.


Assuntos
Neoplasias Induzidas por Radiação/secundário , Tumores Neuroendócrinos/secundário , Neoplasias Orbitárias/secundário , Compostos Radiofarmacêuticos/efeitos adversos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Somatostatina/análogos & derivados , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética , Neoplasias Induzidas por Radiação/etiologia , Tumores Neuroendócrinos/etiologia , Neoplasias Orbitárias/etiologia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Somatostatina/efeitos adversos
10.
Ugeskr Laeger ; 180(8)2018 Feb 19.
Artigo em Dinamarquês | MEDLINE | ID: mdl-29493500

RESUMO

The diagnosis of pulmonary embolism (PE) relies on clinical assessment, D-dimer test and diagnostic imaging. Modern CT pulmonary angiography (CTPA), ventilation/perfusion  single-photon emission computed tomography (SPECT) and SPECT/CT are rather equal in terms of sensitivity, specificity and inconclusive results for the diagnosis of PE, outper-forming planar lung scintigraphy. Furthermore, SPECT/CT and CTPA can both provide important information regarding differential diagnoses. Thus, the choice of primary diag-nostic modality relies on local expertise, availability and special circumstances like radiation dose, contraindications and the clinical urgency.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Doença Aguda , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia por Tomografia Computadorizada/normas , Contraindicações de Procedimentos , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Humanos , Embolia Pulmonar/sangue , Embolia Pulmonar/diagnóstico , Doses de Radiação , Cintilografia/efeitos adversos , Cintilografia/normas , Sensibilidade e Especificidade , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/normas , Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único/normas
11.
Cancer Imaging ; 17(1): 16, 2017 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-28592305

RESUMO

BACKGROUND: SPECT/CT has been shown to increase the diagnostic performance of bone scintigraphy for staging of malignancies. A systematic double-bed SPECT/CT of the trunk may allow further improvement. However, this would be balanced by higher dosimetry and longer acquisition time. The objective was to assess the incremental diagnostic utility of a systematic double-bed SPECT/CT acquisition for bone scintigraphy in initial staging of cancer patients, especially compared with the usual approach consisting in a whole body planar scan (WBS) plus one single-bed targeted SPECT/CT. METHODS: One hundred two consecutive patients referred for bone scintigraphy for initial staging of malignancy were analyzed. All patients underwent a double-bed SPECT/CT acquisition of the trunk. Images were interpreted by two nuclear medicine physicians in a 3-step procedure. Firstly, only WBS planar images were used; secondly, one additional single-bed SPECT/CT chosen based on planar images was used; finally, WBS planar and double-bed SPECT/CT images were interpreted. Lesions were classified as benign, equivocal or suspicious for metastasis. A per-lesion, per-anatomical region and per-patient analysis was performed. RESULTS: In a per-lesion analysis, the number of equivocal and suspicious lesions was 91 and 241 using WBS planar images, 17 and 259 using a single-bed SPECT/CT acquisition and 11 and 269 using double-bed SPECT/CT images, respectively. In a per-patient analysis, the diagnostic conclusion was negative, equivocal or suspicious for malignancy in 35, 53 and 14 patients using WB planar images, 77, 6 and 19 patients using an additional single-bed SPECT/CT and 76, 7 and 19 using double-bed SPECT/CT images, respectively. Seventeen lesions unseen on WBS images were interpreted as suspicious (n = 12) or equivocal (n = 5) on double-bed SPECT/CT images. Six lesions unseen on "WBS + targeted single-bed SPECT/CT" were interpreted as suspicious on double-bed SPECT/CT, with no shift in the metastatic status of patients. CONCLUSION: A systematic double-bed SPECT/CT acquisition has a limited incremental diagnostic value over an oriented single-bed SPECT/CT in terms of specificity and conclusiveness of bone scintigraphy in the initial staging of cancer patients. However, it slightly improved the sensitivity of the test by detecting unseen lesions on WBS, which may be of value for initial staging of cancer.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/patologia , Neoplasias Ósseas/secundário , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/normas
12.
J Nucl Med Technol ; 45(3): 214-218, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28473460

RESUMO

This study aimed to determine whether a bismuth-coated latex shield (B-shield) could protect the eyes during brain SPECT/CT. Methods: A shield containing the heavy metal bismuth (equivalent to a 0.15-mm-thick lead shield) was placed over a cylindric phantom and the eyes of a 3-dimensional brain phantom filled with 99mTc solution. Subsequently, phantoms with and without the B-shield were compared using SPECT/CT. The CT parameters were 30-200 mA and 130 kV. The dose reduction achieved by the B-shield was measured using a pencil-shaped ionization chamber. The protective effects of the B-shield were determined by evaluating relative radioactivity concentration as well as artifacts (changes in CT number), linear attenuation coefficients, and coefficients of variation on SPECT images. Results: The radiation doses with and without the B-shield were 0.14-0.77 and 0.36-1.93 mGy, respectively, and the B-shield decreased the average radiation dose by about 60%. The B-shield also increased the mean CT number, but only at locations just beneath the surface of the phantom. Streaks of higher density near the underside of the B-shield indicated beam hardening. Linear attenuation coefficients and the coefficients of variation did not significantly differ between phantoms with and without the B-shield, and the relative 99mTc radioactivity concentrations were not affected. Conclusion: The B-shield decreased the radiation dose without affecting estimated attenuation correction or radioactivity concentrations. Although surface artifacts increased with the B-shield, the quality of the SPECT images was acceptable. B-shields can help protect pediatric patients and patients with eye diseases who undergo SPECT imaging.


Assuntos
Bismuto/química , Encéfalo/diagnóstico por imagem , Lesões da Córnea/prevenção & controle , Dispositivos de Proteção dos Olhos , Exposição à Radiação/prevenção & controle , Lesões por Radiação/prevenção & controle , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Lesões da Córnea/etiologia , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Látex/química , Látex/efeitos da radiação , Teste de Materiais , Imagens de Fantasmas , Exposição à Radiação/análise , Lesões por Radiação/etiologia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos
13.
Nucl Med Commun ; 38(6): 546-555, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28430740

RESUMO

PURPOSE: This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). METHODS: One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. RESULTS: The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. CONCLUSION: AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.


Assuntos
Coração/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Fatores Etários , Automação , Criança , Pré-Escolar , Humanos , Lactente , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/efeitos adversos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...